Search NASA⌕ Search

SEARCH · Search NASA

Results for “Vibration Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Subsychronous vibration of multistage centrifugal compressors forced by rotating stall

A multistage centrifugal compressor, in natural gas re-injection service on an offshore petroleum production platform, experienced subsynchronous vibrations which caused excessive bearing wear. Field performance testing correlated the subsynchronous amplitude with the discharge flow coefficient, demonstrating the excitation to be aerodynamic. Adding two impellers allowed an increase in the diffuser flow angle (with respect to tangential) to meet the diffuser stability criteria based on factory and field tests correlated using the theory of Senoo (for rotating stall in a vaneless diffuser). This modification eliminated all significant subsynchronous vibrations in field service, thus confirming the correctness of the solution. Other possible sources of aerodynamically induced vibrations were considered, but the judgment that those are unlikely has been confirmed by subsequent experience with other similar compressors.

Fulton, J. W.↗

Piezoelectric pushers for active vibration control of rotating machinery

The active control of rotordynamic vibrations and stability by magnetic bearings and electromagnetic shakers have been discussed extensively in the literature. These devices, though effective, are usually large in volume and add significant weight to the stator. The use of piezoelectric pushers may provide similar degrees of effectiveness in light, compact packages. Tests are currently being conducted with piezoelectric pusher-based active vibration control. Results from tests performed on NASA test rigs as preliminary verification of the related theory are presented.

Palazzolo, Alan B.↗

Piezoelectric pushers for active vibration control of rotating machinery

The active control of rotordynamic vibrations and stability by magnetic bearings and electromagnetic shakers have been discussed extensively in the literature. These devices, though effective, are usually large in volume and add significant weight to the stator. The use of piezoelectric pushers may provide similar degrees of effectiveness in light, compact packages. Tests are currently being conducted with piezoelectric pusher-based active vibration control. Results from tests performed on NASA test rigs as preliminary verification of the related theory are presented.

Palazzolo, A. B.↗

Development of an integrated aeroservoelastic analysis program and correlation with test data

The details and results are presented of the general-purpose finite element STructural Analysis RoutineS (STARS) to perform a complete linear aeroelastic and aeroservoelastic analysis. The earlier version of the STARS computer program enabled effective finite element modeling as well as static, vibration, buckling, and dynamic response of damped and undamped systems, including those with pre-stressed and spinning structures. Additions to the STARS program include aeroelastic modeling for flutter and divergence solutions, and hybrid control system augmentation for aeroservoelastic analysis. Numerical results of the X-29A aircraft pertaining to vibration, flutter-divergence, and open- and closed-loop aeroservoelastic controls analysis are compared to ground vibration, wind-tunnel, and flight-test results. The open- and closed-loop aeroservoelastic control analyses are based on a hybrid formulation representing the interaction of structural, aerodynamic, and flight-control dynamics.

Gupta, K. K.↗

Effect of vertical active vibration isolation on tracking performance and on ride qualities

An investigation to determine the effect on pilot performance and comfort of an active vibration isolation system for a commercial transport pilot seat is reported. The test setup consisted of: a hydraulic shaker which produced random vertical vibration inputs; the active vibration isolation system; the pilot seat; the pilot control wheel and column; the side-arm controller; and a two-axis compensatory tracking task. The effects of various degrees of pilot isolation on short-term (two-minute) tracking performance and comfort were determined.

Dimasi, F. P.↗

Summary of AH-1G flight vibration data for validation of coupled rotor-fuselage analyses

Under a NASA research program designated DAMVIBS (Design Analysis Methods for VIBrationS), four U. S. helicopter industry participants (Bell Helicopter, Boeing Vertol, McDonnell Douglas Helicopter, and Sikorsky Aircraft) are to apply existing analytical methods for calculating coupled rotor-fuselage vibrations of the AH-1G helicopter for correlation with flight test data from an AH-1G Operational Load Survey (OLS) test program. Bell Helicopter, as the manufacturer of the AH-1G, was asked to provide pertinent rotor data and to collect the OLS flight vibration data needed to perform the correlations. The analytical representation of the fuselage structure is based on a NASTRAN finite element model (FEM) developed by Bell which has been extensively documented and correlated with ground vibration tests.The AH-1G FEM was provided to each of the participants for use in their coupled rotor-fuselage analyses. This report describes the AH-1G OLS flight test program and provides the flight conditions and measured vibration data to be used by each participant in their correlation effort. In addition, the mechanical, structural, inertial and aerodynamic data for the AH-1G two-bladed teetering main rotor system are presented. Furthermore, modifications to the NASTRAN FEM of the fuselage structure that are necessary to make it compatible with the OLS test article are described. The AH-1G OLS flight test data was found to be well documented and provide a sound basis for evaluating currently existing analysis methods used for calculation of coupled rotor-fuselage vibrations.

Dompka, R. V.↗

TESTING OF THE DUAL ROTARY FILTER SYSTEM

The Savannah River National Laboratory (SRNL) installed and tested two hydraulically connected SpinTek rotary microfilter (RMF) units to determine the behavior of a multiple filter system. Both units were successfully controlled by a control scheme written in DELTA-V architecture by Savannah River Remediation (SRR) Process Control Engineering personnel. The control system was tuned to provide satisfactory response to changing conditions during the operation of the multi-filter system. Stability was maintained through the startup and shutdown of one of the filter units while the second was still in operation. The installation configuration originally proposed by the Small Colum Ion Exchange (SCIX) project of independent filter and motor mountings may be susceptible to vibration. Significant stiffening of the filter and motor mounts was required to minimize the vibration. Alignment of the motor to the filter was a challenge in this test configuration. The deployment configuration must be easy to manipulate and allow for fine adjustment. An analysis of the vibration signature of the test system identified critical speeds. Whether it corresponds to the resonance frequency of a rotor radial vibration mode that was excited by rotor unbalance is uncertain based upon the measurements. A relative motion series should be completed on the filter with the final shaft configuration to determine if the resonances exist in the final filter design. The instrumentation selected for deployment, including the concentrate discharge control valve and flow meters, performed well. Automation of the valve control integrated well with the control scheme and when used in concert with the other control variables, allowed automated control of the dual RMF system. The one area of concern with the instrumentation was the condition resulting when the filtrate flow meter operated with less than three gpm. This low flow was at the lower range of performance for the flow meter. This should not be an issue in deployment where the desired flow rate will be within the normal operating range of the meter. Testing demonstrated that the use of a flexible line for the filtrate discharge is highly desired at the outlet of the rotary union to transition to the system piping. Isolating the vibration from the rotary union will significantly improve the lifetime of the seals. Methods to monitor and isolate individual filters should be considered during deployment. The ability to diagnose issues and isolate individual filters would allow isolation prior to failure. Thus, filters may be cleaned or repaired instead of requiring complete replacement if the condition were to continue unnoticed. Isolating the filtrate line of each filter during startup will minimize the premature buildup of solids on the filter disks. Several tests have shown that the method of filter startup can improve performance lifetime of the filters. The installation must factor in an air inlet for the draining of a filter that does not involve a reverse flow through the filter disks. The reverse flow may cause deformation of the disks or may damage other components of the filters themselves.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Correlation of AH-1G airframe test data with a NASTRAN mathematical model

Test data was provided for evaluating a mathematical vibration model of the Bell AH-1G helicopter airframe. The math model was developed and analyzed using the NASTRAN structural analysis computer program. Data from static and dynamic tests were used for comparison with the math model. Static tests of the fuselage and tailboom were conducted to verify the stiffness representation of the NASTRAN model. Dynamic test data were obtained from shake tests of the airframe and were used to evaluate the NASTRAN model for representing the low frequency (below 30 Hz) vibration response of the airframe.

Cronkhite, J. D.↗

Analysis Background & Noise in Stretched Wire Alignment Technique Measurements

The Stretched-Wire Alignment Technique (SWAT) is one method of magnet alignment for linear induction accelerators. The applications of SWAT have been implemented for aligning solenoid magnets on the Scorpius linear induction accelerator which will be sited at the Nevada National Security Site and the Flash X-Ray (FXR) linear induction accelerator at Lawrence Livermore National Laboratory’s Contained Firing Facility. This article describes both systematic (repeatable) and random sources of background and noise as well as practical ways to eliminate or reduce them to acceptable levels. Systematic sources include reflections from wire ends, rapid sag due to ohmic heating of the wire, magnetic materials, and shot rate. Random sources include air currents, vibration of nearby equipment, mechanical stability of test equipment, and the instruments used to measure the wire motion. Mitigations include curve fitting and adaptive noise signal cancellation, and mechanical damping. Finite Element Analysis (FEA) was used to identify and resolve a repeatable wire vibration frequency interfering with the signal resolution. Two stretched wire alignment technique set ups from Sandia National Labs and Lawrence Livermore National Lab have shown background noise sources and ways of mitigating them by either analysis methods or change of mechanical configuration. Conclusions that were drawn included the severe sensitivity of the deflection to even small external interferences of the SWAT wire such that it requires attention to detail in mechanical set up and analysis.

Linear Inductive Accelerator↗

Experiments on reduction of propeller induced interior noise by active control of cylinder vibration

The feasibility of reducing interior noise caused by advanced turbo propellers by controlling the vibration of aircraft fuselages was investigated by performing experiments in an anechoic chamber with an aircraft model test rig and apparatus. It was found that active vibration control provides reasonable global attenuation of interior noise levels for the cases of resonant (at 576 Hz) and forced (at 708 Hz) system response. The controlling mechanism behind the effect is structural-acoustic coupling between the shell and the contained field, termed interface modal filtering.

Fuller, C. R.↗

Reliability study of opto-coupled semiconductor devices and Light Emitting Diodes (LED)

Opto-coupler and light emitting diode (LED) failure mechanisms and associated activation energies were determind from the results of environmental and accelerated lift tests of over 2,400 devices. The evaluation program included LED phototransistor opto-couplers from three sources, LED photoamplifier opto-couplers from a single source, and discrete infrared emitting LEDs from two sources. Environmental tests to evaluate device mechanical integrity included power cycling (10,000 cycles), temperature cycling (500 cycles) and a sequence of monitored shock, monitored vibration and constant acceleration. Multiple temperature operating life tests were conducted at ambient temperatures between 25 C and 200 C. Opto-couplers were operated in both the 'on' and 'off' states during life testing.

Maurer, R. C.↗

Wind-Tunnel Evaluation of the Effect of Blade Nonstructural Mass Distribution on Helicopter Fixed-System Loads

This report provides data obtained during a wind-tunnel test conducted to investigate parametrically the effect of blade nonstructural mass on helicopter fixed-system vibratory loads. The data were obtained with aeroelastically scaled model rotor blades that allowed for the addition of concentrated nonstructural masses at multiple locations along the blade radius. Testing was conducted for advance ratios ranging from 0.10 to 0.35 for 10 blade-mass configurations. Three thrust levels were obtained at representative full-scale shaft angles for each blade-mass configuration. This report provides the fixed-system forces and moments measured during testing. The comprehensive database obtained is well-suited for use in correlation and development of advanced rotorcraft analyses.

ARES-1(AEROELASTIC ROTOR EXPERIMENTAL SYSTEM 1)↗

American-Made Geothermal Geophone Prize: Ultra-High Temperature Seismic Tool for Geothermal Wells Summary Report

This work was conducted in support of the American Made Geothermal Prize. The following data summary report presents the testing conducted at Sandia National Labs to validate the performance of the Ultra-High Temperature Seismic Tool for Geothermal Wells. The goal of the testing was to measure the sensitivity of the device to seismic vibrations and reliability of the instrument at elevated temperatures. To this end, two tests were conducted: 1) Ambient Temperature Seismic Testing, which measured the response of the tool to a sweep of frequencies from 1 to 1000 Hz, and 2) Elevated Temperature Survivability Testing which measured the voltage response of the device at 225°C over a month-long testing window. The details of the testing methodology and summary of the tests are presented herein.

15 GEOTHERMAL ENERGY↗

Diagnostics and Active Control of Aircraft Interior Noise

This project deals with developing advanced methods for investigating and controlling interior noise in aircraft. The work concentrates on developing and applying the techniques of Near Field Acoustic Holography (NAH) and Principal Component Analysis (PCA) to the aircraft interior noise dynamic problem. This involves investigating the current state of the art, developing new techniques and then applying them to the particular problem being studied. The knowledge gained under the first part of the project was then used to develop and apply new, advanced noise control techniques for reducing interior noise. A new fully active control approach based on the PCA was developed and implemented on a test cylinder. Finally an active-passive approach based on tunable vibration absorbers was to be developed and analytically applied to a range of test structures from simple plates to aircraft fuselages.

Fuller, C. R.↗

Umbilical Stiffness Matrix Characterization and Testing for Microgravity Science Payloads

This paper describes efforts of testing and analysis of various candidate cables and umbilicals for International Space Station microgravity science payloads. The effects of looping, large vs. small displacements, and umbilical mounting configurations were assessed. A 3-DOF stepper motor driven fixture was used to excite the umbilicals. Forces and moments were directly measured in all three axes with a 6-DOF load cell in order to derive suitable stiffness matrices for design and analysis of vibration isolation controllers. Data obtained from these tests were used to help determine the optimum type and configuration of umbilical cables for the International Space Station microgravity science glovebox (MSG) vibration isolation platform. The data and procedures can also be implemented into control algorithm simulations to assist in validation of actively controlled vibration isolation systems. The experimental results of this work are specific in support of the Glovebox Integrated Microgravity Isolation Technology (g-LIMIT) isolation platform, to be located in the microgravity science glovebox aboard the U.S. Destiny Laboratory Module.

Engberg, Robert C.↗

A Modal Model to Simulate Typical Structural Dynamic Nonlinearity [PowerPoint]

Some initial investigations have been published which simulate nonlinear response with almost traditional modal models: instead of connecting the modal mass to ground through the traditional spring and damper, a nonlinear Iwan element was added. This assumes that the mode shapes do not change with amplitude and there are no interactions between modal degrees of freedom. This work expands on these previous studies. An impact experiment is performed on a structure which exhibits typical structural dynamic nonlinear response, i.e. weak frequency dependence and strong damping dependence on the amplitude of vibration. Use of low level modal test results in combination with high level impacts are processed using various combinations of modal filtering, the Hilbert Transform and band-pass filtering to develop response data that are then fit with various nonlinear elements to create a nonlinear pseudo-modal model. Simulations of forced response are compared with high level experimental data for various nonlinear element assumptions.

42 ENGINEERING↗

Time-dependent approach to spin-vibronic coupling: Implementation and assessment

In this work, we present the generalization of a time-dependent method for the calculation of intersystem crossing (ISC) rates in the Condon approximation. When ISC takes place between electronic states with the same orbital type, i.e., when the transition is forbidden according to the El-Sayed rules, it is necessary to go beyond the Condon approximation. Similar to the Herzberg-Teller expansion of the vibronic interaction, the electronic spin–orbit matrix elements are assumed to depend linearly on the nuclear coordinates. The ISC rate is then a sum of three contributions: a direct, mixed direct-vibronic, and vibronic term. The method, presented in this work, is based on the generating function formalism and the multi-mode harmonic oscillator approximation. In addition to the zero-temperature case, we implemented formulae for finite-temperature conditions assuming a Boltzmann population of vibrational levels in the initial state. Tests have been carried out for a variety of molecules for which literature data were available. We computed vibronic one-photon spectra of free-base porphyrin and free-base chlorin and calculated ISC rates for xanthone, thioxanthone, thionine, as well as free-base porphyrin and found excellent agreement with previous results. Quantitative rates for triplet formation in rhodamine A have been determined theoretically for the first time. We find the S{sub 1}↝ T{sub 2} channel to be the major source of triplet rhodamine formation in the gas phase.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗