Distributed Online Voltage Control in Distribution Network: A Two-Stage Real-Time Implementation

The increasing integration of renewable-based distributed generation (DG) brings growing challenges to distribution network (DN) voltage control. To address this issue, a two-stage distributed online voltage control framework (TDO-VC) is proposed in this paper. In the proposed method, legacy voltage control devices are controlled in the upper stage on an hourly timescale, while DGs operate autonomously online in the lower stage to remove instantaneous voltage violations. The idea of receding horizon control is applied in the upper stage to comprehensively consider the current and future renewable generation, and the generalized fast dual ascent (Gf-DA) is employed in the lower stage to effectively manage DGs through near real-time optimization. The effectiveness of the proposed TDO-VC is demonstrated by rigorous theoretical analysis and case studies on IEEE-123 bus system.

Distributed generation↗

Coordinated Voltage Regulator Control in Systems with High-level Penetration of Distributed Energy Resources

Voltage Control is one of the fundamental operational requirements for power systems, which can become very challenging in presence of distributed energy resources (DERs). This paper presents a novel method for inclusion of voltage regulators (VRs) in a distributed voltage control framework for distribution networks. The goal is to coordinate and optimize the operation of voltage regulators. Of special interest are networks with high penetration of distributed energy resources, PVs in particular, which exhibit overvoltage problems. To that end, we have adopted a dynamic VR model from the literature and applied the proposed coordinated control method on a modified IEEE 123 test system with very high penetration of PVs. Over Voltage Severity Index (OVSI) and Cumulative Voltage Variation Index (CVVI) have been defined and used in the algorithm to control the regulation steps of VRs. The developed method is compared against the base case with no control and the results show its effectiveness in coordinated VR control.

Cumulative Voltage Variation Index (CVVI)↗

Scalable and Memory-Efficient Algorithms for Controlling Networked Epidemic Processes Using Multiplicative Weights Update Method

We study the problem of designing scalable algorithms to find effective intervention strategies for controlling stochastic epidemic processes on networks. This is a common problem arising in agent based models for epidemic spread. Previous approaches to this problem focus on either heuristics with no guarantees or approximation algorithms that scale only to networks corresponding to county-sized populations, typically, with less than a million nodes. In particular, the mathematical-programming based approaches need to solve the Linear Program (LP) relaxation of the problem using an LP solver, which restricts the scalability of this approach. In this work, we overcome this restriction by designing an algorithm that adapts the multiplicative weights update (MWU) framework, along with the sample average approximation (SAA) technique, to approximately solve the linear program (LP) relaxation for the problem. To scale this approach further, we provide a memory-efficient algorithm that enables scaling to large networks, corresponding to country-size populations, with over 300 million nodes and 30 billion edges. Furthermore, we show that this approach provides near-optimal solutions to the LP in practice.

Sambaturu, Prathyush↗

Variable loop gain using excessive regeneration for a delayed wide-area control system

Disclosed are methods and systems for adjusting a High Voltage Direct Current (HVDC) compensator output signal to an HVDC system to reduce control loop modulus due to excessive time delay of sensor measurements. Two different time windows, a Short-Time Variance Window (STVW) and an Extended-Time Variance Window (ETVW) may be examined for detection of increased energy. To detect increased energy the HVDC compensator output signal may be passed through a bandpass filter, then variances for the STVW and ETVW may be generated to produce corresponding test statistics. The STVW and ETVW test statistics may be compared to hypothesis test thresholds and have binary logic based on the hypothesis test comparisons used to generate a gain. The gain may then be multiplied times the original HVDC feedback compensator output such that the adjusted HVDC feedback compensator output reduces the control loop modulus when applied to the HVDC system.

Roberson, Dakota↗

Apparatus and method supporting wireless access to multiple security layers in an industrial control and automation system or other system

A method includes receiving a message at a first wireless node. The first wireless node is associated with a first wired network, and the first wired network is associated with a first security layer. The method also includes transmitting the message over the first wired network when at least one destination of the message is located in the first security layer. The method further includes wirelessly transmitting the message for delivery to a second wireless node when at least one destination of the message is located in a second security layer. The second wireless node is associated with a second wired network, and the second wired network is associated with the second security layer. The first and second security layers may be associated with different security paradigms and/or different security domains. Also, the message could be associated with destinations in the first and second security layers.

42 ENGINEERING↗

Control of hydrogen content and fuel recycling for long pulse high performance plasma operation in EAST

Control of fuel recycling and hydrogen content in the Experimental Advanced Superconducting Tokamak (EAST) using various methods is studied for high-power long pulse high confinement mode (H-mode) plasma operation. The results show that long duration first wall baking and discharge cleaning in EAST provides the necessary clean vacuum environment with a high ultimate vacuum of 3.6 × 10 -6 Pa and low outgassing rate of ~1.5 × 10 -4 Pa m 3 s -1 for plasma operation. In-vessel cryopumps are found to provide an efficient method for particle recycling control in the divertor region to decrease global recycling coefficient (R global ) from ~1.0 to ~0.8 during ohmic heating plasmas, and it provides a high particle exhausting rate of 10 20_ 10 21 D-atoms s -1 in high-power plasma operations. Long duration silicon coating is found to be more powerful than baking and discharge cleaning, which reduces the H/(H + D) ratio gradually to a value as low as 8%, and lithium coating is more effective and more efficient than silicon coating, to further reduce the H/(H + D) ratio to 3%. Real-time lithium powder injection is a novel method for recycling control, which reduces R global from 0.94 to 0.82 under lithium coating wall conditioning. By the combination and optimization of the above methods, H-mode plasmas with low hydrogen content and low fuel recycling have been achieved in EAST and have been extended gradually to 101 s in 2017. Recycling flux has even decreased gradually during 101 s H-mode plasmas due to increased first wall temperature and the resulting increased Li-II emission. These results provide valuable references on hydrogen content and fuel recycling control for long pulse H-mode plasmas of up to 400–1000 s with high-power heating in EAST and future fusion devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonlinear power flow control for networked AC/DC microgrids

A method for designing feedforward and feedback controllers for integration of stochastic sources and loads into a nonlinear networked AC/DC microgrid system is provided. A reduced order model for general networked AC/DC microgrid systems is suitable for HSSPFC control design. A simple feedforward steady state solution is utilized for the feedforward controls block. Feedback control laws are provided for the energy storage systems. A HSSPFC controller design is implemented that incorporates energy storage systems that provides static and dynamic stability conditions for both the DC random stochastic input side and the AC random stochastic load side. Transient performance was investigated for the feedforward/feedback control case. Numerical simulations were performed and provided power and energy storage profile requirements for the networked AC/DC microgrid system overall performance. The HSSPFC design can be implemented in the Matlab/Simulink environment that is compatible with real time simulation/controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wireless sensing and control of temperature using magnetic fields

A method and system for sensing and controlling temperature with magnetic fields are provided. The method comprises placing a compound in thermal communication with a number of temperature or heat sources and placing a number of magnets in thermal communication with the compound. A number of magnetic sensors are placed in electromagnetic communication with the number of magnets. Changes in the magnetic field of the magnets are detected by the sensors and used to determine the temperature of the compound according to a model that maps magnetic field characteristics to temperature. The amount of cure of the compound can then be estimated from the temperature. The temperature or heat sources are controlled in response to the temperature measurement and the estimated amount of cure of the compound.

Chen Mazumdar, Yi↗

Adjusting the specificity of an engine map based on the sensitivity of an engine control parameter relative to a performance variable

Methods and systems for engine control optimization are provided. A first and a second operating condition of a vehicle engine are detected. An initial value is identified for a first and a second engine control parameter corresponding to a combination of the detected operating conditions according to a first and a second engine map look-up table. The initial values for the engine control parameters are adjusted based on a detected engine performance variable to cause the engine performance variable to approach a target value. A first and a second sensitivity of the engine performance variable are determined in response to changes in the engine control parameters. The first engine map look-up table is adjusted when the first sensitivity is greater than a threshold, and the second engine map look-up table is adjusted when the second sensitivity is greater than a threshold.

33 ADVANCED PROPULSION SYSTEMS↗

On the possibility of controlling the wave front of a wide-aperture HF(DF) laser by the method of Talbot interferometry

The possibility of using the method of Talbot interferometry to control the wave fronts of wide-aperture pulsed HF(DF) lasers is studied experimentally. A search for sensitive screens for visualisation of radiation from a HF(DF) laser and other IR lasers is performed. Screens based on fine graphite powder on a rigid substrate proved to be most convenient for recording Talbot interferograms (talbotgrams). The emission of screens excited by laser pulses was detected with a digital photographic camera and images were processed in a PC. High-contrast talbotgrams of multifrequency radiation of a HF laser were obtained, demonstrating the possibility of controlling the wave fronts of HF(DF) lasers by the method of Talbot interferometry without separating an individual laser line. (interferometry)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A summary comparison of design evaluation techniques - 270

Many nuclear power plants in the United States have recently been granted a 20 year extension to their operation license and are considering modernization. The Idaho National Laboratory is committed to successful modernizations and has been identifying and developing candidate technologies for power plants using methods that match the requirements of an integrated system validation. To do so this paper discusses current and potential workload, situation awareness and other performance methods used in evaluating control room design against the criteria defined by the Nuclear Regulatory Commission. The analysis provided is narrowed to the scope of methods surrounding the Light Water Reactor Sustainability research at the Idaho National Laboratory and therefore evaluates only a handful of the numerous methods used in control room modernizing efforts. As such, it was determined the most popular methods for measuring situation awareness, workload, and performance are measurements that rarely measure their intended construct directly and must be inferred. Physiological measures of workload have matured and become more accessible, sensitive, unobtrusive, valid, and objective but are reliant on variable technology. Situation Awareness measures possess little construct validity but eye-tracking technology is a measure progressing in sensitivity, objectivity, and continues to improve in unobtrusiveness. All things considered, this paper has identified a significant need for a more extensive review of the various performance measures used in modernizing control rooms and integrated system validation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Transcriptional control in alicyclobacillus acidocaldarius and associated genes, proteins, and methods

Isolated and/or purified polypeptides and nucleic acid sequences encoding polypeptides from Alicyclobacillus acidocaldarius are provided. Further provided are methods of modulating transcription or transcription or transcriptional control using isolated and/or purified polypeptides and nucleic acid sequences from Alicyclobacillus acidocaldarius.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Engineering chirality at wafer scale with ordered carbon nanotube architectures

Creating artificial matter with controllable chirality in a simple and scalable manner brings new opportunities to diverse areas. Here we show two such methods based on controlled vacuum filtration - twist stacking and mechanical rotation - for fabricating wafer-scale chiral architectures of ordered carbon nanotubes (CNTs) with tunable and large circular dichroism (CD). By controlling the stacking angle and handedness in the twist-stacking approach, we maximize the CD response and achieve a high deep-ultraviolet ellipticity of 40 ± 1 mdeg nm -1 . Our theoretical simulations using the transfer matrix method reproduce the experimentally observed CD spectra and further predict that an optimized film of twist-stacked CNTs can exhibit an ellipticity as high as 150 mdeg nm -1 , corresponding to a g factor of 0.22. Furthermore, the mechanical rotation method not only accelerates the fabrication of twisted structures but also produces both chiralities simultaneously in a single sample, in a single run, and in a controllable manner. The created wafer-scale objects represent an alternative type of synthetic chiral matter consisting of ordered quantum wires whose macroscopic properties are governed by nanoscopic electronic signatures and can be used to explore chiral phenomena and develop chiral photonic and optoelectronic devices.

36 MATERIALS SCIENCE↗

Efficient learning of power grid voltage control strategies via model-based deep reinforcement learning

Here this article proposes a model-based deep reinforcement learning (DRL) method to design emergency control strategies for short-term voltage stability problems in power systems. Recent advances show promising results for model-free DRL-based methods in power systems control problems. But in power systems applications, these model-free methods have certain issues related to training time (clock time) and sample efficiency; both are critical for making state-of-the-art DRL algorithms practically applicable. DRL-agent learns an optimal policy via a trial-and-error method while interacting with the real-world environment. It is also desirable to minimize the direct interaction of the DRL agent with the real-world power grid due to its safety-critical nature. Additionally, the state-of-the-art DRL-based policies are mostly trained using a physics-based grid simulator where dynamic simulation is computationally intensive, lowering the training efficiency. We propose a novel model-based DRL framework where a deep neural network (DNN)-based dynamic surrogate model (SM), instead of a real-world power grid or physics-based simulation, is utilized within the policy learning framework, making the process faster and more sample efficient. However, having stable training in model-based DRL is challenging because of the complex system dynamics of large-scale power systems. We addressed these issues by incorporating imitation learning to have a warm start in policy learning, reward-shaping, and multi-step loss in surrogate model training. Finally, we achieved 97.5% reduction in samples and 87.7% reduction in training time for an application to the IEEE 300-bus test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Human-automated vehicle interactions

This dissertation is proposed to answer the question: how can the interactions between human and automated vehicles be used to improve the overall performance of automated driving technology? Multiple different modules in automated vehicles such as the perception, motion plan and motion control modules can potentially be benefitted from human-automated vehicle interactions. For perception module, the self-correction of faulty sensors can be achieved using human demonstration data. For motion plan and motion control modules, the performance of the low-level motion controller can be improved with the help of human demonstration, and the behavior of the motion planner can be improved using human intervention data during automated driving. Moreover, a better model for a human driver could improve the overall efficiency and comfort of vehicles in connected mixed traffic. In this dissertation, the technical research toward these goals has been completed and has resulted in several peer-reviewed publications. Optimization methods and model predictive control are used extensively to improve energy efficiency while maintaining safe and comfort driving. An inverse model predictive control (IMPC) method has been developed and it has been proven to be effective in modeling the motion of human driven vehicles. The proposed method has demonstrated its benefits in both connected automated highway driving and the bilateral adaptation of human driver and automated driving controller in human-in-the loop simulations. The proposed future research seeks to broaden the application of IMPC by considering a more comprehensive cost function design and applying it to more complex driving situations.

Guo, Longxiang↗