Search NASA⌕ Search

SEARCH · Search NASA

Results for “depth profiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

The Representation of Aerosols in GMAO’s Newest Reanalyses

Over the past few years, NASA’s Global Modelling and Assimilation Office has been working on the configuration and production of three new reanalysis products, GEOS-IT, GiOcean, and MERRA-21C. GEOS-IT, or the Goddard Earth Observing System for Instrument Teams, is a 3D variational data assimilation system that runs in a near real time framework however retrospectively provides data back through 1998 to deliver a consistent view of the Earth-atmosphere system for the production of observational NASA products. Retrospective production for GEOS-IT is complete and the meteorology has since been used to produce the one way weakly coupled GiOcean reanalysis. Due to differences in the atmospheric model, particularly related to scavenging, aerosols are not identical in GEOS-IT and GiOcean. MERRA-21C, or the Modern Era Restrospective analysis for Research and Applications in the 21st century, is a hybrid 4D ensemble variational system at a finer horizontal resolution of 0.25 degrees. Although different in their intended use, and therefore configuration, these systems prominently feature coupling between meteorology and aerosols. The differences and similarities in the aerosol configuration between the three systems will be discussed, covering biomass burning and anthropogenic emissions as well as observations used for the assimilation of aerosol optical depth. A large emphasis will be placed on the version of the underlying aerosol module, GOCART, which underwent a complete refactoring and the addition of radiatively active brown carbon between GEOS-IT and MERRA-21C. Independent observations will be used to evaluate the performance of aerosols in both reanalyses, focusing on aerosol optical depth, surface particulate matter, and vertical profiles of aerosol backscatter.

Allison Collow↗

A simple approach to using an amorphous silicon EPID to verify IMRT planar dose maps

A simplified method of verifying intensity modulated radiation therapy (IMRT) fields using a Varian aS500 amorphous silicon electronic portal imaging device (EPID) is demonstrated. Unlike previous approaches, it does not involve time consuming or complicated analytical processing of the data. The central axis pixel response of the EPID, as well as the profile characteristics obtained from images acquired with a 6 MV photon beam, was examined as a function of field size. Ion chamber measurements at various depths in a water phantom were then collected and it was found that at a specific depth d{sub ref}, the dose response and profile characteristics closely matched the results of the EPID analysis. The only manipulation required to be performed on the EPID images was the multiplication of a matrix of off axis ratio values to remove the effect of the flood field calibration. Similarly, d{sub ref} was found for 18 MV. Planar dose maps at d{sub ref} in a water phantom for a bar pattern, a strip pattern, and 14 clinical IMRT fields from two patient cases each being from a separate anatomical region, i.e., head and neck as well as the pelvis, for both energies were generated by the Pinnacle planning system (V7.4). EPID images of these fields were acquired and converted to planar dose maps and compared directly with the Pinnacle planar dose maps. Radiographic film dosimetry and a MapCHECK dosimetry device (Sun Nuclear Corporation, Melbourne, FL) were used as an independent verification of the dose distribution. Gamma analysis of the EPID, film, and Pinnacle planar dose maps generated for the clinical IMRT fields showed that approximately 97% of all points passed using a 3% dose/3mm DTA tolerance test. Based on the range of fields studied, the author's results appear to justify using this approach as a method to verify dose distributions calculated on a treatment planning system, including complex intensity modulated fields.

61 RADIATION PROTECTION AND DOSIMETRY↗

Modeling of streamflow in a 30 km long reach spanning 5 years using OpenFOAM 5.x

Abstract. Developing accurate and efficient modeling techniques for streamflow at the tens-of-kilometers spatial scale and multi-year temporal scale is critical for evaluating and predicting the impact of climate- and human-induced discharge variations on river hydrodynamics. However, achieving such a goal is challenging because of limited surveys of streambed hydraulic roughness, uncertain boundary condition specifications, and high computational costs. We demonstrate that accurate and efficient three-dimensional (3-D) hydrodynamic modeling of natural rivers at 30 km and 5-year scales is feasible using the following three techniques within OpenFOAM, an open-source computational fluid dynamics platform: (1) generating a distributed hydraulic roughness field for the streambed by integrating water-stage observation data, a rough wall theory, and a local roughness optimization and adjustment strategy; (2) prescribing the boundary condition for the inflow and outflow by integrating precomputed results of a one-dimensional (1-D) hydraulic model with the 3-D model; and (3) reducing computational time using multiple parallel runs constrained by 1-D inflow and outflow boundary conditions. Streamflow modeling for a 30 km long reach in the Columbia River (CR) over 58 months can be achieved in less than 6 d using 1.1 million CPU hours. The mean error between the modeled and the observed water stages for our simulated CR reach ranges from −16 to 9 cm (equivalent to approximately ±7 % relative to the average water depth) at seven locations during most of the years between 2011 and 2019. We can reproduce the velocity distribution measured by the acoustic Doppler current profiler (ADCP). The correlation coefficients of the depth-averaged velocity between the model and ADCP measurements are in the range between 0.71 and 0.83 at 75 % of the survey cross sections. With the validated model, we further show that the relative importance of dynamic pressure versus hydrostatic pressure varies with discharge variations and topography heterogeneity. Given the model's high accuracy and computational efficiency, the model framework provides a generic approach to evaluate and predict the impacts of climate- and human-induced discharge variations on river hydrodynamics at tens-of-kilometers and decadal scales.

58 GEOSCIENCES↗

Predicting the liquefaction phenomena from shear velocity profiling: Empirical approach to 6.3 Mw, May 2006 Yogyakarta earthquake

The liquefactions phenomena have been reported after a shocking 6.5Mw earthquake hit Yogyakarta province in the morning at 27 May 2006. Several researchers have reported the damage, casualties, and soil failure due to the quake, including the mapping and analyzing the liquefaction phenomena. Most of them based on SPT test. The study try to draw the liquefaction susceptibility by means the shear velocity profiling using modified Multichannel Analysis of Surface Waves (MASW). This paper is a preliminary report by using only several measured MASW points. The study built 8-channel seismic data logger with 4.5 Hz geophones for this purpose. Several different offsets used to record the high and low frequencies of surface waves. The phase-velocity diagrams were stacked in the frequency domain rather than in time domain, for a clearer and easier dispersion curve picking. All codes are implementing in Matlab. From these procedures, shear velocity profiling was collected beneath each geophone’s spread. By mapping the minimum depth of shallow water table, calculating PGA with soil classification, using empirical formula for saturated soil weight from shear velocity profile, and calculating CRR and CSR at every depth, the liquefaction characteristic can be identify in every layer. From several acquired data, a liquefiable potential at some depth below water table was obtained.

58 GEOSCIENCES↗

Comparison of satellite-inferred (SAGE II) aerosol optical depths with corresponding airborne sunphotometer optical depths

Solar radiation measurements were made with an airborne multiwavelength autotracking sunphotometer detector off the northeastern coast of Brazil on April 6, 1985. These measurements are used to validate solar radiation measurements from the Stratospheric Aerosol and Gas Experiment (SAGE II). The SAGE II data below 17.5 km are dominated by attenuation due to thunderstorm-generated cirrus clouds. When integrated above 17.5 km, however, the aerosol extinction profiles from SAGE II yield aerosol optical depths that are consistent with the corresponding sunphotometer values above 10.1 km.

Livingston, John M.↗

Subsoil Potassium in Central Iowa Soils: Status and Future Challenges

A reevaluation of plant-available K within central Iowa soils is needed, especially if crop residues are harvested for animal feed or cellulosic feedstock. This study evaluated plant-available K concentrations to depths of 120 cm (n = 2433) within soil profiles at 10 experimental sites. Data from 0- to 5-, 5- to 15-, 0- to 15-, 15- to 30-, 30- to 60-, 60- to 90-, and 90- to 120-cm depths were compiled and evaluated. Based on over 400 samples collected from each depth increment below 15 cm, a reference value of 100 mg kg –1 appears common for central Iowa subsoils. Sixty-four percent of all samples had soil-test K levels below the 120 mg kg –1 threshold for very low nutrient status for crop production in Iowa. Only 28% of surface soil samples (<15-cm depth) were considered to have at least optimum nutrient status with concentrations greater than 160 mg kg –1 . As K is not an environmentally sensitive nutrient, its management in central Iowa soils has generally been neglected in recent years, particularly when compared with N and P management initiatives. Building awareness of soil K profile concentrations, rather than focusing only on surface concentrations, will be necessary to meet nutrient requirements for 21st century agricultural production.

54 ENVIRONMENTAL SCIENCES↗

OBSERVATIONS AND MODELING OF H{sub 2} FLUORESCENCE WITH PARTIAL FREQUENCY REDISTRIBUTION IN GIANT PLANET ATMOSPHERES

Partial frequency redistribution (PRD), describing the formation of the line profile, has negligible observational effects for optical depths smaller than {approx}10{sup 3}, at the resolving power of most current instruments. However, when the spectral resolution is sufficiently high, PRD modeling becomes essential in interpreting the line shapes and determining the total line fluxes. We demonstrate the effects of PRD on the H{sub 2} line profiles observed at high spectral resolution by the Far-Ultraviolet Spectroscopic Explorer (FUSE) in the atmospheres of Jupiter and Saturn. In these spectra, the asymmetric shapes of the lines in the Lyman (v''-6) progression pumped by the solar Ly{beta} are explained by coherent scattering of the photons in the line wings. We introduce a simple computational approximation to mitigate the numerical difficulties of radiative transfer with PRD and show that it reproduces the exact radiative transfer solution to better than 10%. The lines predicted by our radiative transfer model with PRD, including the H{sub 2} density and temperature distribution as a function of height in the atmosphere, are in agreement with the line profiles observed by FUSE. We discuss the observational consequences of PRD and show that this computational method also allows us to include PRD in modeling the continuum pumped H{sub 2} fluorescence treating about 4000 lines simultaneously.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of zinc oxide thin film using atomic force microscopy and optimized X-ray reflectivity by genetic algorithm

For the nanostructured thin films, the study of surface physical parameters is often of crucial importance. For example, the transport properties of ZnO thin film are strongly affected by the geometry of this film. In this study sol—gel ZnO thin film was spin coated on glass substrate. The inverse problem of thin film characterization is formulated as a parameter identification problem in which a set of parameters corresponding to the thin film property can be found by minimizing fitness functions formulated using theoretical and experimental X-ray reflectivity. Atomic force microscopy (AFM) measurements used as an independent procedure for extracting structural parameters of the film and accurate interpretation of X-ray reflectivity data. After applying Fractal calculations on the AFM measured data the Genetic algorithm (GA) method was applied for extracting other important structural parameters. Optimization of specular X-ray reflectivity by GA method gives information along the depth such as thickness, roughness, and electron density profile of layers in the film.

36 MATERIALS SCIENCE↗

SU-F-T-216: Evaluating Dosimetry Accuracy of a Treatment Planning System On Small Proton Fields

Purpose: This study is aiming to identify the smallest field size for which a treatment planning system (TPS) can accurately calculate the relative dose distribution. The finding would be used as a guideline to choose the smallest proton field for clinical treatment. Methods: Mevion S250™ double scattering proton delivery system and Eclipse™ TPS (Varian) with pencil beam convolution (PBC) dose algorithm were used in this study. Square sized fields of 1 cm, 2 cm, 3 cm, 4 cm, 5 cm, and 10 cm were planned on a cubical water phantom with iso-center placed at 10 cm depth. All beams used the same proton beam option: range 15 cm and modulation 10 cm. Dose in water was calculated without any compensator. Gafchromic™ EBT3 film and diode detectors were used to measure the central axis dose distribution and lateral dose profiles at 5 cm, 10 cm, and 14 cm depth. Results: The preliminary film measurement shows good agreement between Eclipse calculated lateral dose profiles for all tested field sizes. The differences on full width half maximum were ≤ 1 mm while the differences on the penumbras were between 1 mm and 2 mm between Eclipse and film. For the depth dose, Eclipse results matched well with film measurements for field sizes down to 2 cm{sup 2}. With smaller field size of 1 cm{sup 2}, Eclipse was able to predict the decreasing of SOBP due to the lack of lateral charged particle equilibrium in depth. However, it did not match the film measurement. Diode measurement results will be available at the time of presentation. Conclusion: The PBC dose algorithm in Eclipse can accurately calculate relative dose distribution in double scattered proton system for field size down to 2 cm{sup 2}.

60 APPLIED LIFE SCIENCES↗

SU-E-T-52: Beam Data Comparison for 20 Linear Accelerators in One Network

Purpose: To compare photon beam data for the 20 Varian linear accelerators (TrueBeam, iX, and EX models) in use at five centers in the same network with the intent to model with one set of beam data in Eclipsec. Methods: Varian linear accelerators, TrueBeam (3), 21 EX, iX, and Trilogy (14), and 6 EX (3), installed between 1999 and 2014 have their 6 MV and 15 MV x-ray beams reevaluated. Full commissioning, including output factors (St), percent depth doses (PDD), and off-axis profiles, was recently performed for a TrueBeam with a cc04 ion chamber in an IBA Blue phantom. Similarly, a subset of beam data for each of the other accelerators was measured recently as follows: for 3×3, 10×10, and 30×30 cm{sup 2} field sizes, flatness and penumbra (80–20%) were measured at dmax and 10 cm depths, PDD were measured at 10 and 20 cm depths, and St were measured at 5 cm depth. Measurement results for all machines were compared. Results: For 15 high-energy (6 and 15 MV) and 3 low-energy machines (6MV only): 1) PDD agreed within 1.4% at 10 and 20 cm depths; 2) penumbra agreed within 1.0 mm at dmax and 10 cm depths; 3) flatness was within 1.3% at dmax and 10 cm depths; and 4) with exception of the three low energy machines, output factors were within 1.1% and 0.5% for 3×3 and 30×30 cm{sup 2}, respectively. Measurement uncertainty, not quantified here, accounts for some of these differences. Conclusion: Measured beam data from 15 high-energy Varian linacs are consistent enough that they can be classified using one beam data set in Eclipse. Two additional high-energy machines are removed from this group until their data are further confirmed. Three low-energy machines will be in a separate class based upon differences in output factors (St)

07 ISOTOPE AND RADIATION SOURCES↗

Apollo 16 core 60013/14 as a product of path 1 and path 2 regolith evolution processes

We have made a petrographic study of 12 samples along the 62 cm profile of Apollo 16 core 60013/14 taken at Station 10 near the lunar module. The basic core description and maturity variations have been discussed earlier. This core is important because it enables a stratigraphic comparison with nearby cores 60001-7 and 60009/10. These cores form a triangle with sides 35-40 m. FMR data show a maturity-match between 60009/10 and 60013/14. Unfortunately, segments of the core 60001-7 are too disturbed for any cm scale comparison. We present new data on the grain size distribution and the modal petrography for six samples from six levels of 60013 using the same approach and rationale used for 60014. We have combined the new data with our previous data on 60014 to plot the variations of grain size distributions and grain type abundances, in the 500-1000 m and 90-150 micrometers size fractions, with depth. Agglutinate abundances match the I sub s/FeO profile and both show a significant break at a depth of about 45 cm, with lower maturity material below that point. Grain size distributions show that for all analyzed samples, the mean grain size is below 90 micrometers. The two lowest samples are somewhat more coarse-grained than the rest of the core. The break at about 45 cm is the most prominent feature of the core and was described during the initial dissection as a pronounced change in color from dark to light. It now seems clear that this break is primarily one of maturity rather than of bulk chemical composition.

Basu, A.↗

Time and space resolved current density mapping in three dimensions using magnetic field probe array in a high voltage coaxial gap

We present an experimental analysis of the symmetry of current density in a coaxial geometry, diagnosed using a magnetic field probe array and calculations of the Fowler-Nordheim enhancement factor. Data were collected on the coaxial gap breakdown device (240 A, 25 kV, 150 ns, ~0.1 Hz), and data from experiments using 2 different gap sizes and different penetration depths are compared over runs comprising 50 shots for each case. The magnetic field probe array quantifies the distribution of current density at three axial locations, on either sides of a vacuum breakdown, and tracks the evolution with time and space. The results show asymmetries in current density, which can be influenced by changes in the gap size and the penetration depth (of the center electrode into the outer electrode). For smaller gap sizes (400 μm), symmetric current profiles were not observed, and the change in the penetration depth changes both the symmetric behavior of the current density and the enhancement factor. For larger gaps (900 μm), current densities were typically more uniform and less influenced by the penetration depth, which is reflected in the enhancement factor values. Furthermore it is possible that the change in inductance caused by the localization of current densities plays a role in the observed behavior.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Handheld White Light Interferometer for Measuring Defect Depth in Windows

Accurate quantification of defects (scratches and impacts) is vital to the certification of flight hardware and other critical components. The amount of damage to a particular component contributes to the performance, reliability, and safety of a system, which ultimately affects the success or failure of a mission or test. The launch-commit criteria on a Space Shuttle Orbiter window are governed by the depth of the defects that are identified by a visual inspection. This measurement of a defect is not easy to obtain given the environment, size of the defect, and location of the window(s). The determination of depth has typically been performed by taking a mold impression and measuring the impression with an optical profiling instrument. Another method of obtaining an estimate of the depth is by using a refocus microscope. To use a refocus microscope, the surface of the glass and bottom of the defect are, in turn, brought into focus by the operator. The amount of movement between the two points corresponds to the depth of the defect. The refocus microscope requires a skilled operator and has been proven to be unreliable when used on Orbiter windows. White light interferometry was chosen as a candidate to replace the refocus microscope. The White Light Interferometer (WLI) was developed to replace the refocus microscope as the instrument used for measuring the depth of defects in Orbiter windows. The WLI consists of a broadband illumination source, interferometer, detector, motion control, displacement sensor, mechanical housing, and support electronics. The illumination source for the WLI is typically a visible light emitting diode (LED) or a near-infrared superluminescent diode (SLD) with power levels of less than a milliwatt. The interferometer is a Michelson configuration consisting of a 1-in. (2.5-cm) cube beam splitter, a 0.5-in. (1.3-cm) optical window as a movable leg (used to closely match the return intensity of the fixed leg from the window), and a mirrored prism to fold the optics into the mechanical housing. The detector may be one of many C-mount CCD (charge-coupled device) cameras. Motion is provided by a commercial nanostepping motor with a serial interface. The displacement sensor is a custom device specifically designed for this application. The mechanical housing and support electronics were designed to integrate the various components into an instrument that could be physically handled by a technician and easily transported.

Youngquist, Robert↗

Scattering of emitted radiation from inhomogeneous and nonisothermal layers

A parametric study is performed for the exiting monochromatic intensities scattered from finite plane-parallel inhomogeneous layers that are driven solely by a distribution of thermal sources. Intensities are obtained by invariantly imbedding the standard and thermal scattering functions. The single-scattering albedo and the Henyey-Greenstein phase-function parameter are varied independently, and both linear and exponential profiles are considered. Linear temperature profiles are used, including temperature inversions. The resulting intensities, as a function of the direction cosine of propagation, are discussed from a remote-sensing point of view. For an isothermal and homogeneous medium, the gross characteristics of the exiting intensity, represented by its overall slope, mean value (magnitude), and an interior maximum value, can be related to the total optical depth, single-scattering albedo, and phase function, respectively. For a homogeneous medium, linearly decreasing (in the line of sight) temperature profiles tend to obscure the phase-function information and decrease the apparent optical depth. On the other hand, linearly increasing temperature profiles tend to retain phase-function information and increase the apparent optical depth. Temperature inversion profiles give intensities very similar to those for purely linear profiles.

Bergstrom, R. W.↗

Correction factors for saturation effects in white light and laser absorption spectroscopy for application to low pressure plasmas

In white light absorption spectroscopy, the broadening of the absorption signal due to the apparatus profile of the spectrometer may lead to an underestimation of the determined density as one measures an apparent optical depth. This is in particular true for high optical depth where saturation effects of the transmitted intensity occur. Provided that the line profile of the absorption line is known, the apparent optical depth effect can be accounted for by introducing a correction factor. The impact of the saturation and the approach of considering the effect are demonstrated for argon and indium lines in low pressure plasmas where correction factors of one order of magnitude or even higher are reached very easily. For the indium line, the hyperfine splitting has been taken into account. In laser absorption, the line profile is resolved. However, the weak but rather broad background emission of the laser diode can cause a saturation signal at the photo diode resulting also in an underestimation of the density obtained from the analysis. It is shown that this can be taken into account by fitting the theoretical line profile to the measured absorption signal which yields also a correction factor. The method is introduced and demonstrated at the example of the cesium resonance line including the hyperfine splitting. Typical correction factors around two are obtained for the cesium ground state density at conditions of a low pressure negative hydrogen ion source in which cesium is evaporated to enhance the negative ion production.

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-F-T-428: An Optimization-Based Commissioning Tool for Finite Size Pencil Beam Dose Calculations

Purpose: Finite size pencil beam (FSPB) algorithms are commonly used to pre-calculate the beamlet dose distribution for IMRT treatment planning. FSPB commissioning, which usually requires fine tuning of the FSPB kernel parameters, is crucial to the dose calculation accuracy and hence the plan quality. Yet due to the large number of beamlets, FSPB commissioning could be very tedious. This abstract reports an optimization-based FSPB commissioning tool we have developed in MatLab to facilitate the commissioning. Methods: A FSPB dose kernel generally contains two types of parameters: the profile parameters determining the dose kernel shape, and a 2D scaling factors accounting for the longitudinal and off-axis corrections. The former were fitted using the penumbra of a reference broad beam’s dose profile with Levenberg-Marquardt algorithm. Since the dose distribution of a broad beam is simply a linear superposition of the dose kernel of each beamlet calculated with the fitted profile parameters and scaled using the scaling factors, these factors could be determined by solving an optimization problem which minimizes the discrepancies between the calculated dose of broad beams and the reference dose. Results: We have commissioned a FSPB algorithm for three linac photon beams (6MV, 15MV and 6MVFFF). Dose of four field sizes (6*6cm2, 10*10cm2, 15*15cm2 and 20*20cm2) were calculated and compared with the reference dose exported from Eclipse TPS system. For depth dose curves, the differences are less than 1% of maximum dose after maximum dose depth for most cases. For lateral dose profiles, the differences are less than 2% of central dose at inner-beam regions. The differences of the output factors are within 1% for all the three beams. Conclusion: We have developed an optimization-based commissioning tool for FSPB algorithms to facilitate the commissioning, providing sufficient accuracy of beamlet dose calculation for IMRT optimization.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-359: Measurement of Various Metrics to Determine Changes in Megavoltage Photon Beam Energy

Purpose: To examine the relationship between photon beam energy and various metrics for energy on the flattened and flattening filter free (FFF) beams generated by the Varian TrueBeam. Methods: Energy changes were accomplished by adjusting the bending magnet current ±10% from the nominal value for the 4, 6, 8, and 10 MV flattened and 6 and 10 MV FFF beams. Profiles were measured for a 30×30 cm{sup 2} field using a 2D ionization chamber array and a 3D water Scanner which was also used to measure PDDs. For flattened beams we compared several energy metrics; PDD at 10 cm depth in water (PDD(10)); the variation over the central 80% of the field (Flat); and the average of the highest reading along each diagonal divided by the CAX value, diagonal normalized flatness (FDN). For FFF beams we examined PDD(10), FDN, and the width of a chosen isodose level in a 30×30 cm{sup 2} field (W(d%)). Results: Changes in PDD(10) were nearly linear with changes in energy for both flattened and FFF beams as were changes in FDN. Changes in W(d%) were also nearly linear with energy for the FFF beams. PDD(10) was not as sensitive to changes in energy compared to the other metrics for either flattened or FFF beams. Flat was not as sensitive to changes in energy compared to FDN for flattened beams and its behavior depends on depth. FDN was the metric that had the highest sensitivity to the changes in energy for flattened beams while W(d%) was the metric that had highest sensitivity to the changes in energy for FFF beams. Conclusions: The metric FDN was found to be most sensitive to energy changes for flattened beams, while the W(d%) was most sensitive to energy changes for FFF beams.

07 ISOTOPE AND RADIATION SOURCES↗

The Analysis and Modeling of the Deployment of NASA's X-38 Parafoil

NASA is currently working on developing the X-38 Crew Return Vehicle for the Internati6nal Space Station (ISS). The aerodynamics of the X-38 and its enormous 7500 square ft parafoil are extremeJy complicated and must be understood and modeled accurately before the vehicle is actually used for human space flight. A large amount of analysis has been performed on the steady state regions of the flight profile when the parafoil is already open. However, the deployment region of the flight profile has not been analyzed in much depth and is a particularly complicated dynamic flight period. During deployment, the X-38 system has its parafoil open up to its full area in five stages over a period of 20-30 seconds. The vehicle transitions from angles of attack around 90 deg to 0 deg in about two seconds and is extremely dynamic. This paper will detail the analysis work done to generate accurate flight profile characteristics of the deployment from flight data from vehicle test drops. Additionally, a computer simulation tool for steady state flight was modified to analyze and model the parafoil deployment. Eventually, a computer model was produced that generated accurate representations of the parafoil deployment dynamics for the vehicle test drops to date.

Ranier, Chris↗