Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed PV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Using Artificial Soiling to Rank Anti-Soiling Coatings for Arid Climates

A simple method to evaluate (e.g., screen and rank) the performance of coatings that are fully or partially anti-soiling (AS) is lacking within the PV industry. Artificial soiling may be used as a rapid and economical assessment approach, offering an efficient alternative to time-intensive, site-specific field testing. In this study, we present an artificial soiling method to replicate the anti-soiling performance rankings of two groups of coated glass samples supplied by two manufacturers (group C with CA, CP, and CS coatings; group A with AC coating). These are compared to field aging in two climates: semi-arid Lemoore, California over 4 months, and the hot desert in Mesa, Arizona over 7 months. Both field and indoor performance ranking utilize the transmittance ratio, defined as the optical transmittance between a coated sample and an uncoated reference in each group, as an evaluation metric to assess the effectiveness of the artificial soiling approach in replicating field soiling. It is critical to mimic the dominant field meteorological conditions associated with soiling-prone days and vulnerable times of day during the soiling season. Our results reveal that the use of artificial soiling for field performance ranking among coatings strongly depends on the soil type (composition and particle distribution), dust surface density, and prevalent environmental factors (wetting saturation by humidity, dew condensation extent, and prior weathering history of the coating). The similar rank order relative to the field suggests that the artificial soiling approach presented may be used for down-selecting anti-soiling coatings prior to prolonged field validation.

14 SOLAR ENERGY↗

Effects of sodium and potassium on the photovoltaic performance of CIGS solar cells

Here, the deliberate introduction of K and Na into Cu(In, Ga)Se 2 (CIGS) absorbers was investigated by varying a combination of an SiO 2 diffusion barrier, coevaporation of KF with the CIGS absorber, and a KF postdeposition treatment (PDT). Devices made with no diffusion barrier and KF coevaporation treatment exhibited the highest photovoltaic conversion efficiency with the smallest overall distribution in key current density-voltage (J-V) performance metrics. Out-diffusion of Na and K from the substrate, KF coevaporation, and KF PDT all increased carrier concentration, open-circuit voltage, fill factor, and power conversion efficiency. Quantum-efficiency analysis of devices highlighted the greatest loss in the short-circuit current density due to incomplete absorption and collection. Secondary ion mass spectrometry illustrated the efficacy of the SiO 2 film as a sodium and potassium diffusion barrier, as well as their relative concentration in the absorber. Introduction of KF appeared to enhance diffusion of Na from the substrate, in agreement with previous studies.

14 SOLAR ENERGY↗

Operation and Control of a PV Converter with Enhanced Stability Based on Virtual Impedance Emulation in a Pseudo Resistive Grid

A three-phase grid-connected photo-voltaic converter is investigated to enhance its operational capabilities and stability margins. These converters are generally connected to the grid with an inductive impedance. In this paper the possibility of using a resistive impedance to enhance the stability of the overall system has been investigated. To reduce the losses in the system, rather than using a real resistance, a virtual resistance is emulated inside the control architecture to ensure resistive power transfer between two sources. The stability results with inductive and resistive grids are presented based on the previously reported frequency response. The overall system is modeled via MATLAB/Simulink and several important case study results are presented in this paper to verify the efficacy of the proposed architecture.

grid-forming controls↗

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control Design of Series-connected PV-powered Grid-forming Converters via Singular Perturbation

We report modular architectures that consist of several series-connected dc-ac converters have been a focal point of recent innovations in transformerless medium-voltage applications. In this paper, we consider an architecture consisting of dc-ac modules containing a quadruple active bridge dc-dc converter, which generates three floating dc links that feed grid-side dc-ac inverters. Practical implementation of such a converter module in PV systems requires a variety of controllers that collectively achieve maximum power point tracking, dc-link regulation, and ac-side power control. Design of such multi-loop systems is generally quite challenging due to the potential for destabilizing interactions among loops. Here we propose a design approach where singular perturbation theory is used to decompose the timescales at which each control loop operates and provides a systematic framework for parametric selection. Our approach also ensures system stability of multiple modules with identical controls connected in series across a grid. The paper concludes with experimental results of three 1000 W series-connected converter modules across a stiff grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Chapter 2: International Requirements for Large Integration of Renewable Energy Sources

Most European countries have concerns about the integration of large amounts of renewable energy sources (RES) into electric power systems, and this is currently a topic of growing interest. In January 2008, the European Commission published the 2020 package, which proposes committing the European Union to a 20% reduction in greenhouse gas emissions, to achieve a target of deriving 20% of the European Union's final energy consumption from renewable sources, and to achieve 20% improvement in energy efficiency both by the year 2020 [1]. Member states have different individual goals to meet these overall objectives, and they each need to provide a detailed roadmap describing how they will meet these legally binding targets [2]. At this time, RES are an indispensable part of the global energy mix, which has been partially motivated by the continuous increases in hydropower as well as the rapid expansion of wind and solar photovoltaic (PV). The International Energy Agency's 2012 edition of the World Energy Outlook stated that the rapid increases in RES integration are underpinned by falling technology costs as well as rising fossilfuel prices and carbon pricing, but RES integration is also encouraged by continued subsidies: from $88 billion globally in 2011 (compared to $523 billion in fossil-fuel subsidies in 2012 [3], with a share of $131 billion for electricity generation) to an estimated $240 billion in 2035 [4]. According to [3], in 2015 RES accounted for 22% of electricity generation, which was approximately the same level as gas and about one-half the level of coal.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control of Greenhouse Gas Emissions by Optimal DER Technology Investment and Energy Management in Zero-Net-Energy Buildings

The U.S. Department of Energy has launched the commercial building initiative (CBI) in pursuit of its research goal of achieving zero-net-energy commercial buildings (ZNEB), i.e. ones that produce as much energy as they use. Its objective is to make these buildings marketable by 2025 such that they minimize their energy use through cutting-edge, energy-efficiency technologies and meet their remaining energy needs through on-site renewable energy generation. This paper examines how such buildings may be implemented within the context of a cost- or CO2-minimizing microgrid that is able to adopt and operate various technologies: photovoltaic modules (PV) and other on-site generation, heat exchangers, solar thermal collectors, absorption chillers, and passive/demand-response technologies. A mixed-integer linear program (MILP) that has a multi-criteria objective function is used. The objective is minimization of a weighted average of the building's annual energy costs and CO2 emissions. The MILP's constraints ensure energy balance and capacity limits. In addition, constraining the building's energy consumed to equal its energy exports enables us to explore how energy sales and demand-response measures may enable compliance with the ZNEB objective. Using a commercial test site in northernCalifornia with existing tariff rates and technology data, we find that a ZNEB requires ample PV capacity installed to ensure electricity sales during the day. This is complemented by investment in energy-efficient combined heat and power (CHP) equipment, while occasional demand response shaves energy consumption. A large amount of storage is also adopted, which may be impractical. Nevertheless, it shows the nature of the solutions and costs necessary to achieve a ZNEB. Additionally, the ZNEB approach does not necessary lead to zero-carbon (ZC) buildings as is frequently argued. We also show a multi-objective frontier for the CA example, whichallows us to estimate the needed technologies and costs for achieving a ZC building or microgrid.

03 NATURAL GAS↗

Adaptive Internal Model Based Current Control with Embedded Active Damping of a Three-Phase Grid-Connected Inverter with LCL Filter for PV Application

This paper presents an internal model based controller with embedded active damping for a three-phase grid-connected inverter with LCL filter. A strategy to control the grid current based on the internal model principle is presented in this paper. It is known that a third-order LCL filter apart from providing better attenuation also poses the problem of initiating unwanted resonance oscillations especially during transients. To address this problem, an active damping strategy based on virtual resistance emulation on the grid side filter is implemented. Also, to ensure effective active damping, an online parameter update strategy is implemented for the filter parameters. The proposed method provides better attenuation to oscillation damping and achieves good tracking performance without adversely affecting the bandwidth. The architecture is verified based on computer simulations via MATLAB/Simulink and PLECS domain and various important case study results are presented.

grid-connected inverter↗

Advanced Solar and Load Forecasting Incorporating HD Sky Imaging: BNL Phase II Activities (Final Report)

Over the last ten years, lower costs and government incentives for rooftop and utility scale solar photovoltaic (PV) systems have led to a rapid growth in the amount of power generated from this renewable energy source. For example, the cumulative PV generating capacity of 1,160 MW in New York State at the end of 2018 represents a growth of more than 4,000% over the past seven years and almost 400% over the past five years. But increased dependence on this inherently variable energy source introduces the need to anticipate, i.e., forecast, changes in energy production and manage them appropriately. Utilities and grid operators can then use this forecast information to balance changes and maintain stability of the electric grid by adding additional sources or diverting excess supplies for sale or storage, as needed. Current techniques based on persistence modeling are not accurate enough to provide reliable forecasts. With support from the U.S. Department of Energy’s Solar Energy Technology Office (DOE SETO) and the New York Power Authority (NYPA), Brookhaven National Laboratory (BNL), the National Center for Atmospheric Research (NCAR), and the Electric Power Research Institute (EPRI) formed a collaborative team to provide reliable forecasting over a range of time intervals. In addition, the forecasting area was scaled up to about 50 km2, a factor of 20 times larger than previously achieved, so that available solar irradiance could be forecast throughout an entire region including both large generating facilities and distributed rooftop solar arrays. In its role, BNL developed a technology for predicting changes in available solar energy from zero to 30 minutes ahead. This “nowcasting” approach uses inexpensive, off-the-shelf, high definition (HD) imagers with custom software to identify and track the movement of approaching clouds and predict their impact on available solar irradiance. The BNL Nowcasting model improves forecasting accuracy by 20 to 50% over current techniques. Forecasting reliability for low clouds (worst case scenario since they move over solar panels more rapidly than high clouds) was calculated to be 95% accurate for forecast periods of five minute ahead. Reliability decreases with longer forecast time intervals and was calculated to be about 80% for 10 minute forecasts, and about 70% for 20 minutes ahead. Clouds were still reliably tracked by the imager network at 60% accuracy for forecast lead times up to about 30 minutes ahead, and this was determined to be the practical nowcasting limit for low clouds in a network of this scale. This work represents the second phase of a multi-phase effort to develop and deploy solar forecasting at a regional scale so that contributions from distributed rooftop solar resources can be forecast along with solar generating facilities, giving utilities and stakeholders an accurate assessment of future energy production. Additional work is planned to operate the forecasting network in an area upstate New York to assess system reliability under diverse meteorological conditions and to monitor system performance over a full range of seasonal variability.

14 SOLAR ENERGY↗

Advanced Hydropower and PSH Capacity Expansion Modeling (Final Report on HydroWIRES D1 Improvements to Capacity Expansion Modeling)

Hydropower and pumped-storage hydropower (PSH) have played a key role in providing flexible, low-carbon electricity to the U.S. electricity system for over a century. As variable generation (VG) deployment increases the demand for flexible, dispatchable generation, it is important to use all available methods for understanding how hydropower and PSH interfaces with VG in a future low-carbon grid. Capacity expansion models (CEMs) of electricity systems are often used to study future electricity scenarios, but these tools often have difficulty representing site- and technology-details of hydropower and PSH due to limited spatial, temporal, or process resolution. This report demonstrates a set of model advancements to improve hydropower and PSH representations in CEMs and other models that consider hydropower and PSH's role in electricity systems. Model advancements include new data integration to define closed-loop PSH resource availability and cost, along with site-level parameterizations of existing PSH capacity and energy storage specifications. Shifting energy across seasons for both hydropower and PSH is explored to demonstrate the potential value of long-duration storage. New representations of hydropower upgrades offer opportunities to increase dispatchability, add pumps, or independently add capacity or energy depending on what is most valuable. New model structures and data are demonstrated individually and in combination to observe their impact on model results and provide initial insights into what is most important for analysts, electricity system planners, and hydropower decision-makers to consider when assessing future roles of hydropower. Improving flexibility of existing hydropower assets has the potential to reduce CO 2 emissions through complementing VG technologies and/or improve electricity system economics by reducing the need to deploy higher-cost systems. Large-scale energy storage is also shown to provide opportunities for balancing seasonal differences in VG, particularly solar photovoltaics (PV). Initial analysis with a new closed-loop PSH resource and cost dataset also demonstrate the potential for new PSH deployment to offer new grid flexibility opportunities. Future analysis and modeling of hydropower's role in the U.S. and other electricity systems could include methodological improvements based on those discussed here along with sensitivity analysis to better represent current and future potential hydropower and PSH flexibility. Improvements to geospatial and site-level data can further improve the understanding of how hydropower and PSH can be upgraded and operated in response to future electricity system needs. This work lays the groundwork to use advanced planning models to explore the range of roles hydropower and PSH can play in the grid of the future.

13 HYDRO ENERGY↗

Dynamically reconfigurable photovoltaic system

A PV system composed of sub-arrays, each having a group of PV cells that are electrically connected to each other. A power management circuit for each sub-array has a communications interface and serves to connect or disconnect the sub-array to a programmable power grid. The power grid has bus rows and bus columns. A bus management circuit is positioned at a respective junction of a bus column and a bus row and is programmable through its communication interface to connect or disconnect a power path in the grid. As a result, selected sub-arrays are connected by selected power paths to be in parallel so as to produce a low system voltage, and, alternately in series so as to produce a high system voltage that is greater than the low voltage by at least a factor of ten.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid-tied PV battery systems.

Grid tied PV energy smoothing was implemented by using a valve regulated lead-acid (VRLA) battery as a temporary energy storage device to both charge and discharge as required to smooth the inverter energy output from the PV array. Inverter output was controlled by the average solar irradiance over the previous 1h time interval. On a clear day the solar irradiance power curve is offset by about 1h, while on a variable cloudy day the inverter output power curve will be smoothed based on the average solar irradiance. Test results demonstrate that this smoothing algorithm works very well. Battery state of charge was more difficult to manage because of the variable system inefficiencies. Testing continued for 30-days and established consistent operational performance for extended periods of time under a wide variety of resource conditions. Both battery technologies from Exide (Absolyte) and East Penn (ALABC Advanced) proved to cycle well at a Partial state of charge over the time interval tested.

25 ENERGY STORAGE↗

Grid tied PV system energy smoothing.

Grid-tied PV energy smoothing was implemented by using a valve regulated lead-acid (VRLA) battery as a temporary energy storage device to both charge and discharge as required to smooth the inverter energy output from the PV array. Inverter output was controlled by the average solar irradiance over the previous 1h time interval. On a clear day the solar irradiance power curve is offset by about 1h, while on a variable cloudy day the inverter output power curve will be smoothed based on the average solar irradiance. Test results demonstrate that this smoothing algorithm works very well. Battery state of charge was more difficult to manage because of the variable system inefficiencies. Testing continued for 30-days and established consistent operational performance for extended periods of time under a wide variety of resource conditions. Both battery technologies from Exide (Absolyte) and East Penn (Advanced Valve Regulated Lead-Acid) proved to cycle well at a partial state of charge over the time interval tested.

14 SOLAR ENERGY↗

A CHIL Validation of Machine Learning-Assisted Methods for Real-Time Controls of Solar PV for Grid Services: Preprint

Recent research has highlighted the potential for solar to act as a zero-marginal-cost and zero-emission flexibility resource on the bulk power system when operated with advanced control systems. To increase the performance of these systems, leading technologies, including machine learning (ML) and hierarchical inverter set point allocation, have been proposed; however, these technologies lack comprehensive validation under real-world application scenarios. This paper addresses this gap by designing and developing a controller-hardware-in-the-loop framework to evaluate the performance of different flexible solar technologies in responding to automatic generation control signals in a closed-loop fashion. Simulation results indicate the superior performance of an ML-based approach compared to the conventional reference-control grouping-based approach, showcasing its potential to support grid stability and operational efficiency.

closed-loop validation↗

Evaluating the Capabilities of Behind-the-Meter Solar-plus-Storage for Providing Backup Power during Long-Duration Power Interruptions [Slides]

The study estimates the performance of behind-the-meter solar PV-plus-energy-storage-systems (PVESS) in providing critical-load or whole-building backup across a wide range of geographies, building types, and power interruption conditions. The study also considers a set of 10 historical long-duration power outage events and evaluates how PVESS could have performed in providing backup power during those specific events. The analysis is the first in what will be a series of studies by Berkeley Lab, in collaboration with the National Renewable Energy Laboratory, on the use of PVESS for backup power. This initial study, which relies on simulated end-use level building loads, solar generation, and storage dispatch, is intended to provide a baseline set of performance estimates and to illustrate key performance drivers.

14 SOLAR ENERGY↗

Inverter Anti-Islanding with Advanced Grid Support in Single- and Multi-Inverter Islands

As PV and other DER systems are connected to the grid at increased penetration levels, island detection may become more challenging for two reasons: 1. In islands containing many DERs, active inverter-based anti-islanding methods may have more difficulty detecting islands because each individual inverter's efforts to detect the island may be interfered with by the other inverters in the island. 2. The increasing numbers of DERs are leading to new requirements that DERs ride through grid disturbances and even actively try to regulate grid voltage and frequency back towards nominal operating conditions. These new grid support requirements may directly or indirectly interfere with anti-islanding controls. This report describes a series of tests designed to examine the impacts of both grid support functions and multi-inverter islands on anti-islanding effectiveness.

14 SOLAR ENERGY↗

Modular, Reconfigurable, High-Energy Technology Development

The Modular, Reconfigurable High-Energy (MRHE) Technology Demonstrator project was to have been a series of ground-based demonstrations to mature critical technologies needed for in-space assembly of a highpower high-voltage modular spacecraft in low Earth orbit, enabling the development of future modular solar-powered exploration cargo-transport vehicles and infrastructure. MRHE was a project in the High Energy Space Systems (HESS) Program, within NASA's Exploration Systems Research and Technology (ESR&T) Program. NASA participants included Marshall Space Flight Center (MSFC), the Jet Propulsion Laboratory (JPL), and Glenn Research Center (GRC). Contractor participants were the Boeing Phantom Works in Huntsville, AL, Lockheed Martin Advanced Technology Center in Palo Alto, CA, ENTECH, Inc. in Keller, TX, and the University of AL Huntsville (UAH). MRHE's technical objectives were to mature: (a) lightweight, efficient, high-voltage, radiation-resistant solar power generation (SPG) technologies; (b) innovative, lightweight, efficient thermal management systems; (c) efficient, 100kW-class, high-voltage power delivery systems from an SPG to an electric thruster system; (d) autonomous rendezvous and docking technology for in-space assembly of modular, reconfigurable spacecraft; (e) robotic assembly of modular space systems; and (f) modular, reconfigurable distributed avionics technologies. Maturation of these technologies was to be implemented through a series of increasingly-inclusive laboratory demonstrations that would have integrated and demonstrated two systems-of-systems: (a) the autonomous rendezvous and docking of modular spacecraft with deployable structures, robotic assembly, reconfiguration both during assembly and (b) the development and integration of an advanced thermal heat pipe and a high-voltage power delivery system with a representative lightweight high-voltage SPG array. In addition, an integrated simulation testbed would have been developed containing software models representing the technologies being matured in the laboratory demos. The testbed would have also included models for non-MRHE developed subsystems such as electric propulsion, so that end-to-end performance could have been assessed. This paper presents an overview of the MRHE Phase I activities at MSFC and its contractor partners. One of the major Phase I accomplishments is the assembly demonstration in the Lockheed Martin Advanced Technology Center (LMATC) Robot-Satellite facility, in which three robot-satellites successfully demonstrated rendezvous & docking, self-assembly, reconfiguration, adaptable GN&C, deployment, and interfaces between modules. Phase I technology maturation results from ENTECH include material recommendations for radiation hardened Stretched Lens Array (SLA) concentrator lenses, and a design concept and test results for a hi-voltage PV receiver. UAH's accomplishments include Supertube heatpipe test results, which support estimates of thermal conductivities at 30,000 times that of an equivalent silver rod. MSFC performed systems trades and developed a preliminary concept design for a 100kW-class modular reconfigurable solar electric propulsion transport vehicle, and Boeing Phantom Works in Huntsville performed assembly and rendezvous and docking trades. A concept animation video was produced by SAIC, wllich showed rendezvous and docking and SLA-square-rigger deployment in LEO.

Carrington, Connie↗

Analysis of Concentrating Solar Power with Thermal Energy Storage in a California 33% Renewable Scenario

This analysis evaluates CSP with TES in a scenario where California derives 33% of its electricity from renewable energy sources. It uses a commercial grid simulation tool to examine the avoided operational and capacity costs associated with CSP and compares this value to PV and a baseload generation with constant output. Overall, the analysis demonstrates several properties of dispatchable CSP, including the flexibility to generate during periods of high value and avoid generation during periods of lower value. Of note in this analysis is the fact that significant amount of operational value is derived from the provision of reserves in the case where CSP is allowed to provide these services. This analysis also indicates that the 'optimal' configuration of CSP could vary as a function of renewable penetration, and each configuration will need to be evaluated in terms of its ability to provide dispatchable energy, reserves, and firm capacity. The model can be used to investigate additional scenarios involving alternative technology options and generation mixes, applying these scenarios within California or in other regions of interest.

14 SOLAR ENERGY↗