Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Robust direct laser acceleration of electrons with flying-focus laser pulses

Direct laser acceleration (DLA) offers a compact source of high-charge, energetic electrons for generating secondary radiation or neutrons. While DLA in high-density plasma optimizes the energy transfer from a laser pulse to electrons, it exacerbates nonlinear propagation effects, such as filamentation, that can disrupt the acceleration process. Here, we show that superluminal flying-focus pulses (FFPs) mitigate nonlinear propagation, thereby enhancing the number of high-energy electrons and resulting x-ray yield. Three-dimensional particle-in-cell simulations show that, compared to a Gaussian pulse of equal energy (1 J) and intensity (2 × 10 20 W/cm 2 ), an FFP produces 80 × more electrons above 100 MeV, increases the electron cutoff energy by 20%, triples the high-energy x-ray yield, and improves x-ray collimation. These results illustrate the ability of spatiotemporally structured laser pulses to provide additional control in the highly nonlinear, relativistic regime of laser-plasma interactions.

Laser-produced plasmas↗

Photon-in photon-out hard X-ray spectroscopy at the Linac Coherent Light Source

X-ray free-electron lasers (FELs) have opened unprecedented possibilities to study the structure and dynamics of matter at an atomic level and ultra-fast timescale. Many of the techniques routinely used at storage ring facilities are being adapted for experiments conducted at FELs. In order to take full advantage of these new sources several challenges have to be overcome. They are related to the very different source characteristics and its resulting impact on sample delivery, X-ray optics, X-ray detection and data acquisition. Here it is described how photon-in photon-out hard X-ray spectroscopy techniques can be applied to study the electronic structure and its dynamics of transition metal systems with ultra-bright and ultra-short FEL X-ray pulses. In particular, some of the experimental details that are different compared with synchrotron-based setups are discussed and illustrated by recent measurements performed at the Linac Coherent Light Source.

43 PARTICLE ACCELERATORS↗

Note: A non-invasive electronic measurement technique to measure the embedded four resistive elements in a Wheatstone bridge sensor

The work shows a measurement technique to obtain the correct value of the four elements in a resistive Wheatstone bridge without the need to separate the physical connections existing between them. Two electronic solutions are presented, based on a source-and-measure unit and using discrete electronic components. The proposed technique brings the possibility to know the mismatching or the tolerance between the bridge resistive elements and then to pass or reject it in terms of its related common-mode rejection. Experimental results were taken in various Wheatstone resistive bridges (discrete and magnetoresistive integrated bridges) validating the proposed measurement technique specially when the bridge is micro-fabricated and there is no physical way to separate one resistive element from the others.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Motion of 3-6 keV Nonthermal Sources Along the Legs of a Flare Loop

Observations of nonthermal X-ray sources me critical to studying electron acceleration and transport in solar flares. Strong thermal emission radiated from the preheated plasma before the flare impulsive phase often makes it difficult to detect low-energy X-ray sources that are produced by relatively low-energy nonthermal electrons. Knowledge of the distribution of these low-energy nonthermal electrons is particularly important in determining the total nonthermal electron energy in solar flares. We report on an 'early impulsive flare' in which impulsive hard X-ray emission was seen early in the flare before the soft X-ray emission had risen significantly, indicating limited plasma pre-heating. Early in the flare, RHESSI < 25 keV images show coronal sources that moved first downward and then upwards along the legs of a flare loop. In particular, the 3-6 keV source appeared as a single coronal source at the start of the flare, and then it involved into two coronal sources moving down along the two legs of the loop. After nearly reaching the two footpoints at the hard X-ray peak, the two sources moved back up to the looptop again. RHESSI images and light curves all indicate that nonthermal emission dominated at energies as low as 3-6 keV. We suggest that the evolution of both the spectral index and the low-energy cutoff of the injected electron distribution could result in the accelerated electrons reaching a lower altitude along the legs of the dense flare loop and hence result in the observed downward and upward motions of the nonthermal sources.

Sui, Linhui↗

Reduced Parasitic Lasing in Ti:Sapphire Lasers. Removing a Bottleneck to New Ways of Acceleration

Powerful solid state lasers can be efficient sources of high energy electrons in a new concept of particle acceleration. One limitation to the power of these lasers is the phenomenon of parasitic lasing, in which oscillations transverse to the intended lasing direction can drain the stored energy and thus clamp the gain at some maximum value. This problem becomes more severe the larger the laser crystal becomes. The source of the problem is the internal reflections in the larger sized gain material. This program was aimed at eliminating this bottleneck to more powerful lasers, to allow more intense high energy beams to be generated by this technique. The basic approach was to eliminate the internal reflections by making an absorbing layer on the outside of the crystal that had the same refractive index as the crystal. Thus, any transverse light would be absorbed before it reached the edge of the crystal and had a chance to reflect back into the interior. During the first year, furnaces were renovated that and used to produce evaluation crystals. The first approach was to oxidize the outside surface of the titanium doped sapphire laser gain crystal. This oxidation is known to make the crystal be absorbing in the lasing wavelengths. A number of tests showed some modest absorption. After the first year, 2 parallel paths were pursued to improve on this initial results – overgrowth and oxidation and grooving with index matched thermoplastic. Experiments on one of these techniques progressed to near-operational status as a commercial coating process. A test Ti:sapphire rod with a commercial coating technique was also supplied to the subcontractor for baseline testing. The final product of the Phase II was a process that was reduced to a commercialized operation involving the complex series of steps of fabricating the crystal, polishing, grooving, providing an AR coating, then producing the absorbing layer and packaging the crystal in a manner that would allow easy handling for installation and deinstallation.

43 PARTICLE ACCELERATORS↗

DE 1 particle and wave observations in Auroral Kilometric Radiation (AKR) source regions

The high-altitude plasma instrument on board the DE 1 satellite was operating during several near crossings of the AKR source in the nightside auroral region. Observations of electron distributions indicate a region of perpendicular heating adjacent to, and within, the source region. Loss cones, trapped particles, beams, and electron conical distributions are also observed near and within the source region, which extends perpendicular to the magnetic field line for at least 20 km. Near the AKR source region wave-particle interactions appear to have modified the observed electron distributions. We compare the observations to those predicted by recently published numerical simulations.

Menietti, J. D.↗

Recent developments of ion sources for life-science studies at the Heavy Ion Medical Accelerator in Chiba (invited)

With about 1000-h of relativistic high-energy ion beams provided by Heavy Ion Medical Accelerator in Chiba, about 70 users are performing various biology experiments every year. A rich variety of ion species from hydrogen to xenon ions with a dose rate of several Gy/min is available. Carbon, iron, silicon, helium, neon, argon, hydrogen, and oxygen ions were utilized between 2012 and 2014. Presently, three electron cyclotron resonance ion sources (ECRISs) and one Penning ion source are available. Especially, the two frequency heating techniques have improved the performance of an 18 GHz ECRIS. The results have satisfied most requirements for life-science studies. In addition, this improved performance has realized a feasible solution for similar biology experiments with a hospital-specified accelerator complex.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EUV and Hard X-ray Hartmann Wavefront Sensing for Optical Metrology, Alignment and Phase Imaging

For more than 15 years, Imagine Optic have developed Extreme Ultra Violet (EUV) and X-ray Hartmann wavefront sensors for metrology and imaging applications. These sensors are compatible with a wide range of X-ray sources: from synchrotrons, Free Electron Lasers, laser-driven betatron and plasma-based EUV lasers to High Harmonic Generation. In this paper, we first describe the principle of a Hartmann sensor and give some key parameters to design a high-performance sensor. We also present different applications from metrology (for manual or automatic alignment of optics), to soft X-ray source optimization and X-ray imaging.

20 metrology↗

Negative-ion formation in the explosives RDX, PETN, and TNT using the Reversal Electron Attachment Detection (READ) technique

In the search for high sensitivity and direct atmospheric sampling of trace species, techniques have been developed such as atmospheric-sampling, glow-discharge ionization (ASGDI), corona discharge, atmospheric pressure ionization (API), electron-capture detection (ECD), and negative-ion chemical ionization (NICI) that are capable of detecting parts-per-billion to parts-per-trillion concentrations of trace species. These techniques are based on positive- or negative-ion formation via charge-transfer to the target, or electron capture under multiple-collision conditions in a Maxwellian distribution of electron energies at the source temperature. One drawback of the high-pressure, corona- or glow-discharge devices is that they are susceptible to interferences either through indistinguishable product masses, or through undesired ion-molecule reactions. The ASGDI technique is relatively immune from such interferences, since at target concentrations of less than 1 ppm the majority of negative ions arises via electron capture rather than through ion-molecule chemistry. A drawback of the conventional ECD, and possibly of the ASGDI, is that they exhibit vanishingly small densities of electrons with energies in the range 0-10 millielectron volts (meV), as can be seen from a typical Maxwellian electron energy distribution function at T = 300 K. Slowing the electrons to these subthermal (less than 10 meV) energies is crucial, since the cross section for attachment of several large classes of molecules is known to increase to values larger than 10(exp -12) sq cm at near-zero electron energies. In the limit of zero energy these cross sections are predicted to diverge as epsilon(exp -1/2), where epsilon is the electron energy. In order to provide a better 'match' between the electron energy distribution function and attachment cross section, a new concept of attachment in an electrostatic mirror was developed. In this scheme, electrons are brought to a momentary halt by reversing their direction with electrostatic fields. At this turning point the electrons have zero or near-zero energy. A beam of target molecules is introduced, and the resultant negative ions extracted. This basic idea has been recently improved to allow for better reversal geometry, higher electron currents, lower backgrounds, and increased negative-ion extraction efficiency. We present herein application of the so-called reversal electron attachment detector (READ) to the study of negative-ion formation in the explosives molecules RDX, PETN, and TNT under single-collision conditions.

Chutijian, Ara↗

Dependence of the source performance on plasma parameters at the BATMAN test facility

The investigation of the dependence of the source performance (high j{sub H{sup −}}, low j{sub e}) for optimum Cs conditions on the plasma parameters at the BATMAN (Bavarian Test MAchine for Negative hydrogen ions) test facility is desirable in order to find key parameters for the operation of the source as well as to deepen the physical understanding. The most relevant source physics takes place in the extended boundary layer, which is the plasma layer with a thickness of several cm in front of the plasma grid: the production of H{sup −}, its transport through the plasma and its extraction, inevitably accompanied by the co-extraction of electrons. Hence, a link of the source performance with the plasma parameters in the extended boundary layer is expected. In order to characterize electron and negative hydrogen ion fluxes in the extended boundary layer, Cavity Ring-Down Spectroscopy and Langmuir probes have been applied for the measurement of the H{sup −} density and the determination of the plasma density, the plasma potential and the electron temperature, respectively. The plasma potential is of particular importance as it determines the sheath potential profile at the plasma grid: depending on the plasma grid bias relative to the plasma potential, a transition in the plasma sheath from an electron repelling to an electron attracting sheath takes place, influencing strongly the electron fraction of the bias current and thus the amount of co-extracted electrons. Dependencies of the source performance on the determined plasma parameters are presented for the comparison of two source pressures (0.6 Pa, 0.45 Pa) in hydrogen operation. The higher source pressure of 0.6 Pa is a standard point of operation at BATMAN with external magnets, whereas the lower pressure of 0.45 Pa is closer to the ITER requirements (p ≤ 0.3 Pa)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Transverse beam profile measurement system for the Duke storage ring

The transverse beam emittance is a crucial parameter determining the brightness of an electron storage ring based synchrotron radiation source. The beam emittance is typically determined using the transverse electron beam size and the beta function at a particular location. For a low energy storage ring, the direct imaging method using visible/UV light has many advantages, including being simple, straightforward, and cost-effective. The resolution of such a system can be quite adequate for measuring electron beams with a reasonably large transverse beam size. In this work, we present the development of a new transverse beam profile measurement system for the Duke storage ring. This new system has been characterized to allow absolute measurements of the electron beam size while achieving better system resolution than previously thought possible for the direct imaging technique. The preliminary measurement results show that this system is capable of measuring the horizontal beam size over a wide range of the electron beam energies and currents. The system has also been demonstrated as a useful tool to study the intra-beam scattering related emittance increase in the storage ring.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a compact ECR ion source for various ion production

There is a desire that a carbon-ion radiotherapy facility will produce various ion species for fundamental research. Although the present Kei2-type ion sources are dedicated for the carbon-ion production, a future ion source is expected that could provide: (1) carbon-ion production for medical use, (2) various ions with a charge-to-mass ratio of 1/3 for the existing Linac injector, and (3) low cost for modification. A prototype compact electron cyclotron resonance (ECR) ion source, named Kei3, based on the Kei series has been developed to correspond to the Kei2 type and to produce these various ions at the National Institute of Radiological Sciences (NIRS). The Kei3 has an outer diameter of 280 mm and a length of 1120 mm. The magnetic field is formed by the same permanent magnet as Kei2. The movable extraction electrode has been installed in order to optimize the beam extraction with various current densities. The gas-injection side of the vacuum chamber has enough space for an oven system. We measured dependence of microwave frequency, extraction voltage, and puller position. Charge state distributions of helium, carbon, nitrogen, oxygen, and neon were also measured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HERSCHEL GALACTIC PLANE SURVEY OF [N ii] FINE STRUCTURE EMISSION

We present the first large-scale high angular resolution survey of ionized nitrogen in the Galactic Plane through emission of its two fine structure transitions ([N ii]) at 122 and 205 μm. The observations were largely obtained with the PACS instrument onboard the Herschel Space Observatory. The lines of sight were in the Galactic plane, following those of the Herschel OTKP project GOT C+. Both lines are reliably detected at the 10{sup −8}–10{sup −7} Wm{sup −2} sr{sup −1} level over the range –60° ≤ l ≤ 60°. The rms of the intensity among the 25 PACS spaxels of a given pointing is typically less than one third of the mean intensity, showing that the emission is extended. [N ii] is produced in gas in which hydrogen is ionized, and collisional excitation is by electrons. The ratio of the two fine structure transitions provides a direct measurement of the electron density, yielding n(e) largely in the range 10–50 cm{sup −3} with an average value of 29 cm{sup −3} and N{sup +} column densities 10{sup 16}–10{sup 17} cm{sup −2}. [N ii] emission is highly correlated with that of [C ii], and we calculate that between 1/3 and 1/2 of the [C ii] emission is associated with the ionized gas. The relatively high electron densities indicate that the source of the [N ii] emission is not the warm ionized medium (WIM), which has electron densities more than 100 times smaller. Possible origins of the observed [N ii] include the ionized surfaces of dense atomic and molecular clouds, the extended low-density envelopes of H ii regions, and low-filling factor high-density fluctuations of the WIM.

79 ASTRONOMY AND ASTROPHYSICS↗

Study of Electromagnetic Interactions in the MicroBooNE Liquid Argon Time Projection Chamber

This thesis presents results on the study of electromagnetic (EM) activity in the MicroBooNE Liquid Argon Time Projection Chamber (LArTPC) neutrino detector. The LArTPC detector technology provides bubble-chamber like information on neutrino interaction final states, necessary to perform precision measurements of neutrino oscillation parameters. Accelerator-based oscillation experiments heavily rely on the appearance channel ! e to make such measurements. Identifying and reconstructing the energy of the outgoing electrons from such interactions is therefore crucial for their success. This work focuses on two sources of EM activity: Michel electrons in the 10-50 MeV energy range, and photons from 0 decay in the 30-300 MeV range. Studies of biases in the energy reconstruction measurement, and energy resolution are performed. The impact of shower topology at different energies is discussed, and the importance of thresholding and other reconstruction effects on producing an asymmetric and biased energy measurement are highlighted. This work further presents a study of the calorimetric separation of electrons and photons with a focus on the shower energy dependence of the separation power.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Discrete extrasolar X-ray sources.

Galactic X ray sources observed in EM spectrum high energy region, discussing hot plasma cloud thermal radiation and electrons synchrotron radiation as emission sources

Rossi, B. B.↗

Ultraviolet converter transients induced by electrons

The output of ultraviolet converters typically used in satellite astronomy was monitored during irradiation with electrons from a sealed SR-90 source which approximated the peak flux in earth's outer electron belt. The signal induced by irradiation was attributed to two mechanisms: (1) photoelectrons resulting from photons created in the MgF2 window and (2) the direct impact of electrons on the phosphor. For irradiation at about 1 x 10 to the 7th e/sq cm sec, these two effects produced signals which were, in order of magnitude, the same as those produced by an incident UV flux (254 nm) of 10 to the 8th and 10 to the 7th photons/sq cm sec, respectively. In addition, the induced signal was investigated as a function of electron energy by irradiating another converter with 0.4-1.8-MeV electrons from a Van de Graaff. These results suggest that the dominant contribution to the electron-induced signal is Cerenkov photon production in the MgF2 window.

Kernell, R. L.↗

Magnetic field-aligned particle precipitation

Magnetic field-aligned particle fluxes are a common auroral phenomenon. Precipitating field-aligned electrons are seen in the vicinity of auroral arcs as suprathermal bursts, as well as superimposed on the more isotropic inverted V electron precipitation. Electron distribution functions reveal two distinct source populations for the inverted V and field-aligned electron components, and also suggest possible acceleration mechanisms. The inverted V electrons are a hot, boundary plasma sheet population that gains the full parallel acceleration. The field-aligned component appears to originate from cold ionospheric electrons that may be distributed throughout the acceleration region. A turbulent parallel field might explain the apparent lifetime of cold electrons in the acceleration region.

Carlson, C. W.↗

Europa Missions: Generic Materials Test Methodology

This viewgraph presentation discusses: radiation fundamentals, radiation damage, how radiation dosage is determined, fluence testing approaches, ionization damage exposure, displacement damage exposure, Europa energy "bins", rationale for group flux (energy bins), electron/proton group fluences, electron beam exposure testing, proton sources, reactor exposures, gamma exposures, preliminary exposure findings, testing caveats, preliminary conclusions, internal discharge, and electron dose depth curves.

radiation↗