Search NASA⌕ Search

SEARCH · Search NASA

Results for “error rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Quantifying the impact of respiratory-gated 4D CT acquisition on thoracic image quality: A digital phantom study

Purpose: Prospective respiratory-gated 4D CT has been shown to reduce tumor image artifacts by up to 50% compared to conventional 4D CT. However, to date no studies have quantified the impact of gated 4D CT on normal lung tissue imaging, which is important in performing dose calculations based on accurate estimates of lung volume and structure. To determine the impact of gated 4D CT on thoracic image quality, the authors developed a novel simulation framework incorporating a realistic deformable digital phantom driven by patient tumor motion patterns. Based on this framework, the authors test the hypothesis that respiratory-gated 4D CT can significantly reduce lung imaging artifacts. Methods: Our simulation framework synchronizes the 4D extended cardiac torso (XCAT) phantom with tumor motion data in a quasi real-time fashion, allowing simulation of three 4D CT acquisition modes featuring different levels of respiratory feedback: (i) “conventional” 4D CT that uses a constant imaging and couch-shift frequency, (ii) “beam paused” 4D CT that interrupts imaging to avoid oversampling at a given couch position and respiratory phase, and (iii) “respiratory-gated” 4D CT that triggers acquisition only when the respiratory motion fulfills phase-specific displacement gating windows based on prescan breathing data. Our framework generates a set of ground truth comparators, representing the average XCAT anatomy during beam-on for each of ten respiratory phase bins. Based on this framework, the authors simulated conventional, beam-paused, and respiratory-gated 4D CT images using tumor motion patterns from seven lung cancer patients across 13 treatment fractions, with a simulated 5.5 cm{sup 3} spherical lesion. Normal lung tissue image quality was quantified by comparing simulated and ground truth images in terms of overall mean square error (MSE) intensity difference, threshold-based lung volume error, and fractional false positive/false negative rates. Results: Averaged across all simulations and phase bins, respiratory-gating reduced overall thoracic MSE by 46% compared to conventional 4D CT (p ∼ 10{sup −19}). Gating leads to small but significant (p < 0.02) reductions in lung volume errors (1.8%–1.4%), false positives (4.0%–2.6%), and false negatives (2.7%–1.3%). These percentage reductions correspond to gating reducing image artifacts by 24–90 cm{sup 3} of lung tissue. Similar to earlier studies, gating reduced patient image dose by up to 22%, but with scan time increased by up to 135%. Beam paused 4D CT did not significantly impact normal lung tissue image quality, but did yield similar dose reductions as for respiratory-gating, without the added cost in scanning time. Conclusions: For a typical 6 L lung, respiratory-gated 4D CT can reduce image artifacts affecting up to 90 cm{sup 3} of normal lung tissue compared to conventional acquisition. This image improvement could have important implications for dose calculations based on 4D CT. Where image quality is less critical, beam paused 4D CT is a simple strategy to reduce imaging dose without sacrificing acquisition time.

60 APPLIED LIFE SCIENCES↗

Evaluation of errors in prior mean and variance in the estimation of integrated circuit failure rates using Bayesian methods

The critical point of any Bayesian analysis concerns the choice and quantification of the prior information. The effects of prior data on a Bayesian analysis are studied. Comparisons of the maximum likelihood estimator, the Bayesian estimator, and the known failure rate are presented. The results of the many simulated trails are then analyzed to show the region of criticality for prior information being supplied to the Bayesian estimator. In particular, effects of prior mean and variance are determined as a function of the amount of test data available.

Fletcher, B. C.↗

Idealized simulation study of the relationship of disdrometer sampling statistics with the precision of precipitation rate measurement

Due to the discretized nature of rain, the measurement of a continuous precipitation rate by disdrometers is subject to statistical sampling errors. Here, Monte Carlo simulations are employed to obtain the precision of rain detection and rate as a function of disdrometer collection area and compared with World Meteorological Organization guidelines for a 1 min sample interval and 95 % probability. To meet these requirements, simulations suggest that measurements of light rain with rain rates R ≤ 0.50 mm h-1 require a collection area of at least 6 cm × 6 cm, and for R = 1 mm h -1 , the minimum collection area is 13 cm × 13 cm. For R = 0.01 mm h -1 , a collection area of 2 cm × 2 cm is sufficient to detect a single drop. Simulations are compared with field measurements using a new hotplate device, the Differential Emissivity Imaging Disdrometer. The field results suggest an even larger plate may be required to meet the stated accuracy, likely in part due to non-Poissonian hydrometeor clustering.

54 ENVIRONMENTAL SCIENCES↗

Real-time estimators for scattering observables: A full account of finite-volume errors for quantum simulation

The real-time correlators of quantum field theories can be directly probed through new approaches to simulation, such as quantum computing and tensor networks. This provides a new framework for computing scattering observables in lattice formulations of strongly interacting theories, such as lattice quantum chromodynamics. In this paper, we prove that the proposal of real-time estimators of scattering observables is universally applicable to all scattering observables of gapped quantum field theories. All finite-volume errors are exponentially suppressed, and the rate of this suppression is controlled by the regulator considered, namely, a displacement of the spectrum of the theory into the complex plane. A partial restoration of Lorentz symmetry by averaging over different boosts gives an additional suppression of finite volume errors. Our results also apply to the simulation of wave packet scattering, where a similar averaging is performed to construct the wave packets that regulate the finite volume effects. This result represents a necessary key step toward determining a broad class of scattering observables via quantum computing that are currently inaccessible via classical computing. Such observables are relevant for various applications, including hadron spectroscopy, hadron structure, and precision tests of the Standard Model. We also comment on potential applications of our results to traditional computational schemes.

Burbano, Ivan M. [University of California, Berkel↗

Revised Heating Load Line Analysis: Addendum to ORNL/TM-2015/281

The original heating load line analysis of ORNL TM-2015/281 was modified to incorporate two adjustments of (1) removing mechanical ventilation and (2) resizing the heat pump units based on new criteria. This resulted in a lowering of the HLL slope factor from the originally rounded 1.3 level to 1.15 in DOE Region IV and V while leaving unchanged the zero-load ambient at a rounded value of 55 F. For the other four DOE regions, the zero-load ambients dropped by 1 to 2 F from those found earlier and the rounded HLL slope factors ranged from 1.05 to 1.3. The average rounded HLL slope factor over all six DOE regions is 1.15. Effects of the revised slope factor on rated HSPFs (Region IV) for single- and two-capacity units dropped from 16% in the original work to 12.6% in this report. For VS units, the HSPF reductions of 14 to 25% in the original report were lowered to a range of 9 to 21%. As in the original report, for VS units that do not limit minimum speed operation below 47 F ambient, the average HSPF reduction for the cases evaluated is approximately the same as for single- and two-capacity units. For VS units that do limit minimum speed operation below 47 F ambient, the lower 1.15 slope factor of this report generally results in small overpredictions of rated HSPF by 1 to 3% compared to functional HSPF. An exception is minimum-speed-limited VS units where the minimum speed COP at 47 F is higher than that at 62 F; one such unit was found to have an HSPF overprediction of over 14% with the 1.15 HLL slope factor level. For such VS exception cases, a default HSPF penalty should be considered. For the more typical VS units that limit minimum speed operation, use of a 1.15 slope factor for rated HSPF was found to still acceptably limit the HSPF error. If slope factors lower than 1.15 are used for HSPF ratings, some means should be considered to appropriately derate the HSPFs for VS units which limit minimum speed operation below 47 F ambient.

42 ENGINEERING↗

WE-H-BRC-05: Catastrophic Error Metrics for Radiation Therapy

Purpose: Intuitive evaluation of complex radiotherapy treatments is impractical, while data transfer anomalies create the potential for catastrophic treatment delivery errors. Contrary to prevailing wisdom, logical scrutiny can be applied to patient-specific machine settings. Such tests can be automated, applied at the point of treatment delivery and can be dissociated from prior states of the treatment plan, potentially revealing errors introduced early in the process. Methods: Analytical metrics were formulated for conventional and intensity modulated RT (IMRT) treatments. These were designed to assess consistency between monitor unit settings, wedge values, prescription dose and leaf positioning (IMRT). Institutional metric averages for 218 clinical plans were stratified over multiple anatomical sites. Treatment delivery errors were simulated using a commercial treatment planning system and metric behavior assessed via receiver-operator-characteristic (ROC) analysis. A positive result was returned if the erred plan metric value exceeded a given number of standard deviations, e.g. 2. The finding was declared true positive if the dosimetric impact exceeded 25%. ROC curves were generated over a range of metric standard deviations. Results: Data for the conventional treatment metric indicated standard deviations of 3%, 12%, 11%, 8%, and 5 % for brain, pelvis, abdomen, lung and breast sites, respectively. Optimum error declaration thresholds yielded true positive rates (TPR) between 0.7 and 1, and false positive rates (FPR) between 0 and 0.2. Two proposed IMRT metrics possessed standard deviations of 23% and 37%. The superior metric returned TPR and FPR of 0.7 and 0.2, respectively, when both leaf position and MUs were modelled. Isolation to only leaf position errors yielded TPR and FPR values of 0.9 and 0.1. Conclusion: Logical tests can reveal treatment delivery errors and prevent large, catastrophic errors. Analytical metrics are able to identify errors in monitor units, wedging and leaf positions with favorable sensitivity and specificity. In part by Varian.

60 APPLIED LIFE SCIENCES↗

Impact of Surface Curvature on Dose Delivery in Intraoperative High-Dose-Rate Brachytherapy

In intraoperative high-dose-rate (IOHDR) brachytherapy, a 2-dimensional (2D) geometry is typically used for treatment planning. The assumption of planar geometry may cause serious errors in dose delivery for target surfaces that are, in reality, curved. A study to evaluate the magnitude of these errors in clinical practice was undertaken. Cylindrical phantoms with 6 radii (range: 1.35-12.5 cm) were used to simulate curved treatment geometries. Treatment plans were developed for various planar geometries and were delivered to the cylindrical phantoms using catheters inserted into Freiburg applicators of varying dimension. Dose distributions were measured using radiographic film. In comparison to the treatment plan (for a planar geometry), the doses delivered to prescription points were higher on the concave side of the geometry, up to 15% for the phantom with the smallest radius. On the convex side of the applicator, delivered doses were up to 10% lower for small treated areas ({<=} 5 catheters) but, interestingly, the dose error was negligible for large treated areas (>5 catheters). Our measurements have shown inaccuracy in dose delivery when the original planar treatment plan is delivered with a curved applicator. Dose delivery errors arising from the use of planar treatment plans with curved applicators may be significant.

61 RADIATION PROTECTION AND DOSIMETRY↗

Infrared radiative transfer through a regular array of cuboidal clouds

Infrared radiative transfer through a regular array of cuboidal clouds is studied and the interaction of the sides of the clouds with each other and the ground is considered. The theory is developed for black clouds and is extended to scattering clouds using a variable azimuth two-stream approximation. It is shown that geometrical considerations often dominate over the microphysical aspects of radiative transfer through the clouds. For example, the difference in simulated 10 micron brightness temperature between black isothermal cubic clouds and cubic clouds of optical depth 10, is less than 2 deg for zenith angles less than 50 deg for all cloud fractions when viewed parallel to the array. The results show that serious errors are made in flux and cooling rate computations if broken clouds are modeled as planiform. Radiances computed by the usual practice of area-weighting cloudy and clear sky radiances are in error by 2 to 8 K in brightness temperature for cubic clouds over a wide range of cloud fractions and zenith angles. It is also shown that the lapse rate does not markedly affect the exiting radiances for cuboidal clouds of unit aspect ratio and optical depth 10.

HARSHVARDHAN↗

Control system optimization studies. Volume 2: High frequency cutoff filter analysis

The problem of digital implementation of a cutoff filter is approached with consideration to word length, sampling rate, accuracy requirements, computing time and hardware restrictions. Computing time and hardware requirements for four possible programming forms for the linear portions of the filter are determined. Upper bounds for the steady state system output error due to quantization for digital control systems containing a digital network programmed both in the direct form and in the canonical form are derived. This is accomplished by defining a set of error equations in the z domain and then applying the final value theorem to the solution. Quantization error was found to depend upon the digital word length, sampling rate, and system time constants. The error bound developed may be used to estimate the digital word length and sampling rate required to achieve a given system specification. From the quantization error accumulation, computing time and hardware point of view, and the fact that complex poles and zeros must be realized, the canonical form of programming seems preferable.

Fong, M. H.↗

A Comparison of Metallographic Cooling Rate Methods Used in Meteorites

The primary objective of this study was to test the postulate that cooling rates acquired from metal grains in chondrites are consistent with those from iron meteorites. Both types of metal occur in some Group IAB meteorites, which are mixtures of massive metal with well-developed Widmanstatten structures and chondritic inclusions with dispersed metal grains. The grains have textures and compositions similar to chondritic metal, including negligible P. The meteorites studied show little or no sign of shock reheating and textural evidence indicates that silicates and metal were mixed before Widmanstatten patterns formed during cooling. Cooling rates were obtained by comparing measured to modeled taenite grain or lamellae dimensions and central Ni contents. Modeling entails solving diffusion equations using experimental diffusion coefficients, phase relations, and bulk or local Ni and P contents, taking into account geometry, undercooling, and impingement. There is one set of parameters for grains and another, quite different set for Widmanstatten lamellae, including a factor of 30 difference in diffusion coefficients. Yet cooling rates obtained from Widmanstatten structures and metal grains in chondritic inclusions of the same meteorite are consistent; uncertainties in the best data are +/- 10 K/Ma, equivalent to a factor of 1 +/- 0.25. This agreement implies that the data and models are correct or contain fortuitously offsetting errors, which is quite unlikely. Cooling rates range from 40 K/Ma to 70 K/Ma in IAB meteorites that contain both grains and Widmanstatten structures. Rates based on grains in Ni-poor and Ni-rich meteorites lacking Widmansatten patterns expand the range from 30 K/Ma to perhaps 200 K/Ma. Cooling rates correlate with Ni content; Ni-poor meteorites have slower rates than Ni-rich ones. Evidently, IAB meteorites were radially distributed over greater than 30km in a body with a radius less than 50km. A comparison of the available Ar ages with cooling times inferred from the cooling rates suggests that the parent body cooled more slowly after the metallographic cooling rates were established.

Herpfer, Marc A.↗

Comparison of Methods Used to Age Spring–Summer Chinook Salmon in Idaho: Validation and Simulated Effects on Estimated Age Composition

Abstract Validation of aging methods with known-age individuals is rarely done with wild fish. We used samples collected from carcasses of adult Chinook salmon Oncorhynchus tshawytscha that were tagged as juveniles to (1) compare accuracy and precision of ocean ages determined from scales and fin rays and (2) simulate the effects of aging errors on run reconstruction (assignment to migratory cohort) under two age composition scenarios. Scale age had an overall accuracy of 81.8% and was biased high (χ2 = 8.67; P = 0.014). Fin ray age had an overall accuracy of 98.6% and was unbiased (χ2 = 2.00; P = 0.34). Precision of fin ray readings was higher than that of scale readings (coefficient of variation = 2.1% versus 7.8%, respectively). Accuracy of fin ray ages was greater than that of scale ages (Z = 2.198; P = 0.03). For two age composition scenarios, age classification errors were greatest when using scales and least when using fin rays. Aging errors inflated the size of weak cohorts in simulated run reconstructions. We showed how this can cause large errors in estimates of smolt-to-adult return rate when run strength and age composition vary among years. The amount of error associated with scale aging then becomes problematic for tracking the status of both threatened and healthy salmon stocks. Data based on fin ray readings provided the most accurate, unbiased estimates of age structure. Correction for methodological bias is important if age data are to be used in rigorous analyses.

Copeland, Timothy↗

Towards Scaling Law Analysis For Spatiotemporal Weather Data

Compute-optimal scaling laws are relatively well studied for NLP and CV, where objectives are typically single-step and targets are comparatively homogeneous. Weather forecasting is harder to characterize in the same framework: autoregressive rollouts compound errors over long horizons, outputs couple many physical channels with disparate scales and predictability, and globally pooled test metrics can disagree sharply with per-channel, late-lead behavior implied by short-horizon training. We extend neural scaling analysis for autoregressive weather forecasting from single-step training loss to long rollouts and per-channel metrics. We quantify (1) how prediction error is distributed across channels and how its growth rate evolves with forecast horizon, (2) if power law scaling holds for test error, relative to rollout length when error is pooled globally, and (3) how that fit varies jointly with horizon and channel for parameter, data, and compute-based scaling axes. We find strong cross-channel and cross-horizon heterogeneity: pooled scaling can look favorable while many channels degrade at late leads. We discuss implications for weighted objectives, horizon-aware curricula, and resource allocation across outputs.

Kiefer Jr, Alexander [ORNL] (ORCID:000000025398874↗

Scalable fermionic error correction in Majorana surface codes

We study the error correcting properties of Majorana surface codes (MSCs), topological quantum codes constructed out of interacting Majorana fermions, which can be used to store quantum information and perform quantum computation. Furthermore, these quantum memories suffer from purely “fermionic” errors, such as quasiparticle poisoning (QP), that have no analog in conventional platforms with bosonic qubits. In physical realizations where QP dominates, we show that errors can be corrected provided that the poisoning rate is below a threshold of ~11%. When QP is highly suppressed and fermionic bilinear (“bosonic”) errors become dominant, we find an error threshold of ~16%, which is much higher than the threshold for spin-based topological memories like the surface code or the color code. In addition, we derive lattice gauge theories to account for measurement errors. These results, together with the inherent error suppression provided by the superconducting gap in physical realizations of the MSCs, makes this a strong candidate for a robust topological quantum memory.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and development of a portable gamma radiation monitor

A portable gamma radiation monitor has been designed and developed. The monitor can be used effectively in the dose range from 0.07 to 500 mGy/h due to gamma rays of energy greater than 65 keV. The monitor overestimated radiation doses and the uncertainty in the measured dose rate has been found to be {<=}30%. The response of the monitor can be considered isotropic within an acceptable error of {+-}30%. Provision has also been added to use the monitor as an installed radiation monitor. In installed mode, it can be operated from a remote location up to 1 km and the timing history can be stored on a personal computer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dosimetric Accuracy of a Dual Photon Energy Linac at Low Monitor Setting for Various Pulse Repetition Frequencies

Accuracy of dose delivery at low monitor unit setting is studied for a dual photon energy linear accelerator. Dose delivered per MU is found to be constant for both the photon beams for MU settings above 30. For lower MUs there is definite deviation from the calibrated value and the error is found to be increasing as fewer MUs are set for dose delivery. This dose/MU ratio at low MU setting is found to be dose-rate dependent, showing an increasing trend with pulse repetition frequency (PRF). Also, the dosimetric ratio is observed to be mode dependent; its value for an 18 MV beam is almost double that observed in the case of a 6 MV beam at very low MU setting. The magnitude of this error should be determined for each energy so that appropriate corrections can be applied if very low MUs are to be used.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Polynomial-Time Classical Algorithm for Noisy Quantum Circuits

We provide a polynomial-time classical algorithm for noisy quantum circuits. The algorithm computes the expectation value of any observable for any circuit, with a small average error over input states drawn from an ensemble (e.g., the computational basis). Our approach is based upon the intuition that noise exponentially damps nonlocal correlations relative to local correlations. This enables one to classically simulate a noisy quantum circuit by keeping track of only the dynamics of local quantum information. Our algorithm also enables sampling from the output distribution of a circuit in quasipolynomial time, so long as the distribution anticoncentrates. A number of implications are discussed, including a fundamental limit on the efficacy of noise mitigation strategies: For constant noise rates, any quantum circuit for which error mitigation succeeds in polynomial-time on most input states can also be classically simulated in polynomial-time on most input states. Our algorithms scale exponentially in the inverse noise rate, which is fundamental and makes them impractical for current quantum devices.

decoherence↗

Error-trellis Syndrome Decoding Techniques for Convolutional Codes

An error-trellis syndrome decoding technique for convolutional codes is developed. This algorithm is then applied to the entire class of systematic convolutional codes and to the high-rate, Wyner-Ash convolutional codes. A special example of the one-error-correcting Wyner-Ash code, a rate 3/4 code, is treated. The error-trellis syndrome decoding method applied to this example shows in detail how much more efficient syndrome decoding is than Viterbi decoding if applied to the same problem. For standard Viterbi decoding, 64 states are required, whereas in the example only 7 states are needed. Also, within the 7 states required for decoding, many fewer transitions are needed between the states.

Reed, I. S.↗