Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Performance Assessments of Demand Flexibility from Grid-Interactive Efficient Buildings: Issues and Considerations

This SEE Action Network report explains basic concepts and fundamental considerations for assessing the actual demand flexibility performance of buildings participating in demand flexibility programs and responding to time-varying retail rates. Demand flexibility is the capability of distributed energy resources (DERs) to adjust a building’s load profile across different timescales. Assessments determine the timing, location, quantity, and quality of grid services provided. The results can be used for financial settlements and to improve performance of demand flexibility, support its consideration in resource potential studies and electricity system planning, and contribute to cost-effectiveness evaluations. While practitioners and regulators regularly find opportunities to improve performance assessments of demand-related services, to a large degree current best practices are sufficient for basic service offerings as demand flexibility is implemented today. However, advances in assessment practices will be required in a future with grid-interactive efficient buildings (GEBs) that provide continuous demand flexibility by integrating multiple DERs and flexibility modes (load shed, load shift, modulate, and generate). Example practices include using new baseline constructs—including whether baselines are even required for certain building flexibility modes or configurations, deploying more advanced metering and analytics, further developing cybersecurity standards, improving communication standards for increased interoperability, and establishing performance metrics and assessment procedures for load modulation as it is more fully defined and implemented. This report provides information on prioritizing and designing performance assessment elements for demand flexibility programs and time-varying retail rates, assessment protocols, and research and development needs. Additional research sponsored by DOE’s Building Technologies Office offers more detailed technical information on assessing performance of demand flexibility, including definition of performance metrics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A history of the science and politics of climate change: the role of the Intergovernmental Panel on Climate Change

In response to growing concern about human-induced global climate change, the UN Intergovernmental Panel on Climate Change (IPCC) was formed in 1988. Written by its first Chairman, this book is a unique overview of the history of the IPCC. It describes and evaluates the intricate interplay between key factors in the science and politics of climate change, the strategy that has been followed, and the regretfully slow pace in getting to grips with the uncertainties that have prevented earlier action being taken. The book also highlights the emerging conflict between establishing a sustainable global energy system and preventing a serious change in global climate. Contents are: Part I. The Early History of the Climate Change Issue: 1. Nineteenth century discoveries; 2. The natural carbon cycle and life on earth; 3. Global research initiatives in meteorology and climatology; 4. Early international assessments of climate change; Part II. The Climate Change Issue Becomes One of Global Concern: 5. Setting the stage; 6. The scientific basis for a climate convention; 7. Serving the Intergovernmental Negotiating Committee; 8. The Second IPP Assessment Report; 9. In the aftermath of the IPCC Second Assessment; 10. The Kyoto Protocol is agreed and a third assessment begun; 11. A decade of hesitance and slow progress; Part III. A Turning Point in Addressing Climate Change?: 12. Key scientific finding of prime political relevance; 13. Climate change and the future global energy supply system; Concluding remarks. 9 figs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

C4MIP – The Coupled Climate–Carbon Cycle Model Intercomparison Project: Experimental protocol for CMIP6

Coordinated experimental design and implementation has become a cornerstone of global climate modelling. Model Intercomparison Projects (MIPs) enable systematic and robust analysis of results across many models, by reducing the influence of ad hoc differences in model set-up or experimental boundary conditions. As it enters its 6th phase, the Coupled Model Intercomparison Project (CMIP6) has grown significantly in scope with the design and documentation of individual simulations delegated to individual climate science communities. The Coupled Climate–Carbon Cycle Model Intercomparison Project (C4MIP) takes responsibility for design, documentation, and analysis of carbon cycle feedbacks and interactions in climate simulations. These feedbacks are potentially large and play a leading-order contribution in determining the atmospheric composition in response to human emissions of CO 2 and in the setting of emissions targets to stabilize climate or avoid dangerous climate change. For over a decade, C4MIP has coordinated coupled climate–carbon cycle simulations, and in this paper we describe the C4MIP simulations that will be formally part of CMIP6. While the climate–carbon cycle community has created this experimental design, the simulations also fit within the wider CMIP activity, conform to some common standards including documentation and diagnostic requests, and are designed to complement the CMIP core experiments known as the Diagnostic, Evaluation and Characterization of Klima (DECK). C4MIP has three key strands of scientific motivation and the requested simulations are designed to satisfy their needs: (1) pre-industrial and historical simulations (formally part of the common set of CMIP6 experiments) to enable model evaluation, (2) idealized coupled and partially coupled simulations with 1 % per year increases in CO 2 to enable diagnosis of feedback strength and its components, (3) future scenario simulations to project how the Earth system will respond to anthropogenic activity over the 21st century and beyond. This study documents in detail these simulations, explains their rationale and planned analysis, and describes how to set up and run the simulations. Particular attention is paid to boundary conditions, input data, and requested output diagnostics. It is important that modelling groups participating in C4MIP adhere as closely as possible to this experimental design.

54 ENVIRONMENTAL SCIENCES↗

Repopulation of interacting tumor cells during fractionated radiotherapy: Stochastic modeling of the tumor control probability

Purpose: Optimal treatment planning for fractionated external beam radiation therapy requires inputs from radiobiology based on recent thinking about the “five Rs” (repopulation, radiosensitivity, reoxygenation, redistribution, and repair). The need is especially acute for the newer, often individualized, protocols made feasible by progress in image guided radiation therapy and dose conformity. Current stochastic tumor control probability (TCP) models incorporating tumor repopulation effects consider “stem-like cancer cells” (SLCC) to be independent, but the authors here propose that SLCC-SLCC interactions may be significant. The authors present a new stochastic TCP model for repopulating SLCC interacting within microenvironmental niches. Our approach is meant mainly for comparing similar protocols. It aims at practical generalizations of previous mathematical models. Methods: The authors consider protocols with complete sublethal damage repair between fractions. The authors use customized open-source software and recent mathematical approaches from stochastic process theory for calculating the time-dependent SLCC number and thereby estimating SLCC eradication probabilities. As specific numerical examples, the authors consider predicted TCP results for a 2 Gy per fraction, 60 Gy protocol compared to 64 Gy protocols involving early or late boosts in a limited volume to some fractions. Results: In sample calculations with linear quadratic parameters α = 0.3 per Gy, α/β = 10 Gy, boosting is predicted to raise TCP from a dismal 14.5% observed in some older protocols for advanced NSCLC to above 70%. This prediction is robust as regards: (a) the assumed values of parameters other than α and (b) the choice of models for intraniche SLCC-SLCC interactions. However, α = 0.03 per Gy leads to a prediction of almost no improvement when boosting. Conclusions: The predicted efficacy of moderate boosts depends sensitively on α. Presumably, the larger values of α are the ones appropriate for individualized treatment protocols, with the smaller values relevant only to protocols for a heterogeneous patient population. On that assumption, boosting is predicted to be highly effective. Front boosting, apart from practical advantages and a possible advantage as regards iatrogenic second cancers, also probably gives a slightly higher TCP than back boosting. If the total number of SLCC at the start of treatment can be measured even roughly, it will provide a highly sensitive way of discriminating between various models and parameter choices. Updated mathematical methods for calculating repopulation allow credible generalizations of earlier results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-G-TeP4-05: An Evaluation of a Low Dose Rate (LDR) Prostate Brachytherapy Procedure Using a Failure Modes and Effects Analysis (FMEA)

Purpose: The aim of the study is the application of a Failure Modes and Effects Analysis (FMEA) to access the risks for patients undergoing a Low Dose Rate (LDR) Prostate Brachytherapy Treatment. Methods: FMEA was applied to identify all the sub processes involved in the stages of identifying patient, source handling, treatment preparation, treatment delivery, and post treatment. These processes characterize the radiation treatment associated with LDR Prostate Brachytherapy. The potential failure modes together with their causes and effects were identified and ranked in order of their importance. Three indexes were assigned for each failure mode: the occurrence rating (O), the severity rating (S), and the detection rating (D). A ten-point scale was used to score each category, ten being the number indicating most severe, most frequent, and least detectable failure mode, respectively. The risk probability number (RPN) was calculated as a product of the three attributes: RPN = O X S x D. The analysis was carried out by a working group (WG) at UPMC. Results: The total of 56 failure modes were identified including 32 modes before the treatment, 13 modes during the treatment, and 11 modes after the treatment. In addition to the protocols already adopted in the clinical practice, the prioritized risk management will be implanted to the high risk procedures on the basis of RPN score. Conclusion: The effectiveness of the FMEA method was established. The FMEA methodology provides a structured and detailed assessment method for the risk analysis of the LDR Prostate Brachytherapy Procedure and can be applied to other radiation treatment modes.

60 APPLIED LIFE SCIENCES↗

Comparison of the Efficacy of the Embolic Agents Acrylamido Polyvinyl Alcohol Microspheres and Tris-Acryl Gelatin Microspheres for Uterine Artery Embolization for Leiomyomas: A Prospective Randomized Controlled Trial

Objective: To evaluate the efficacy of acrylamido polyvinyl alcohol microspheres (a-PVAM) as an embolic agent for uterine artery embolization (UAE) compared with Tris-acryl gelatin microspheres (TAGM).Design, Setting, ParticipantsProspective randomized double-blind noninferiority trial. Conducted at two sites both with regional UAE practices. Forty-six women with symptomatic leiomyomas.InterventionUAE procedure was performed with either of the two embolic agents. Either 700-900-{mu}m a-PVAM or 500-700-{mu}m TAGM was used.Main Outcome MeasuresChanges in leiomyoma perfusion, overall uterine volume, and dominant leiomyomas volume measured by contrast-enhanced magnetic resonance imaging at 1 week, 3 months, and 6 months after UAE by a reader blinded to the embolic agent used. Changes in Uterine Fibroid Symptoms and Quality of Life questionnaire scores were measured at 3, 6, and 12 months after UAE. Results: Forty-six patients were randomized and treated under the study protocol (a-PVAM n = 22, TAGM n = 24). There were no procedure-related complications. Two patients were excluded from analysis (one technical failure of the procedure, one withdrawal from study). Successful (>90%) leiomyoma devascularization was observed in 81% of subjects at 1 week after UAE, 97% at 3 months after UAE, and 95% at 6 months after UAE. No significant differences were observed in 14 of 15 outcome measurements, consistent with noninferiority. TAGM was slightly superior to a-PVAM on one comparison (overall quality of life at 3 months after UAE).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Membrane-Based Energy Efficient Dewatering of Microalgae in Biofuels Production and Recovery of Value Added Co-Products

The objective of this paper is to describe the use of membranes for energy efficient biomass harvesting and dewatering. We have evaluated the dewatering of Nannochloropsis sp. with polymeric hollow fiber and tubular inorganic membranes to demonstrate the capabilities of a membrane-based system to achieve microalgal biomass of >150 g/L (dry wt.) and ~99% volume reduction through dewatering. The particle free filtrate containing the growth media is suitable for recycle and reuse. For cost-effective processing, hollow fiber membranes can be utilized to recover 90-95% media for recycle. Tubular membranes can provide additional media and water recovery to achieve target final concentrations. Based on the operating conditions used in this study and taking into scale-up considerations, it can be shown that an integrated hollow fiber-tubular membrane system can process microalgal biomass with at least 80% lower energy requirement compared to traditional processes. Backpulsing was found to be an effective flux maintenance strategy to minimize flux decline at high biomass concentration. An effective chemical cleaning protocol was developed for regeneration of fouled membranes.

biofuels↗

GeantV alpha release

In the fall 2016, GeantV went through a thorough community evaluation of the project status and of its strategy for sharing the R&D results with the LHC experiments and with the HEP simulation community in general. Following this discussion, GeantV has engaged onto an ambitious 2-year road-path aiming to deliver a beta version that has most of the final design and several performance features of the final product, partially integrated with some of the experiment’s frameworks. The initial GeantV prototype has been updated to a vector-aware concurrent framework, which is able to deliver high-density floating-point computations for most of the performance-critical components such as propagation in field and physics models. Electromagnetic physics models were adapted for the specific GeantV requirements, aiming for the full demonstration of shower physics performance in the alpha release at the end of 2017. We have revisited and formalized GeantV user interfaces and helper protocols, allowing to: connect to user code, provide recipes to access efficiently MC truth and generate user data in a concurrent environment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Timeseries Photos of a Variably Inundated Stream: Umtanum Creek, Washington, United States

This dataset is associated with a broader study using game camera timeseries photos collected to evaluate stream variable inundation via changes in width (i.e. wet fraction). Four game cameras were deployed along Umtanum Creek (Washington, United States) to track changes in stream inundation over time. Drone imagery was collected at the same location on October 18, 2024 which was used to construct a digital elevation model (DEM) of the streambed topography. The associated paper and data can be found at https://doi.org/10.1016/j.envsoft.2025.106715 (Bao et al., 2025a)) and https://doi.org/10.15485/2589885 (Bao et al., 2025b), respectively. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. In addition to this readme, this data package also includes a file-level metadata (FLMD) files that describes each file and a data dictionaries (DD) that describe all column/row headers and variable definitions. This dataset is comprised of (1) file-level metadata; (2) data dictionary; (3) readme; (4) field metadata; (5) field protocol; and (5) folders containing game camera photos. Game camera photos are organized into folders for each camera (CDL, CUL, CDR, CUR; see readme for information on camera naming) by the month photos were collected. All files are .csv, .jpg, or .pdf.

AI image segmentation↗

Interpreting biomarker data from the COPHES/DEMOCOPHES twin projects: Using external exposure data to understand biomarker differences among countries

In 2011 and 2012, the COPHES/DEMOCOPHES twin projects performed the first ever harmonized human biomonitoring survey in 17 European countries. In more than 1800 mother–child pairs, individual lifestyle data were collected and cadmium, cotinine and certain phthalate metabolites were measured in urine. Total mercury was determined in hair samples. While the main goal of the COPHES/DEMOCOPHES twin projects was to develop and test harmonized protocols and procedures, the goal of the current paper is to investigate whether the observed differences in biomarker values among the countries implementing DEMOCOPHES can be interpreted using information from external databases on environmental quality and lifestyle. In general, 13 countries having implemented DEMOCOPHES provided high-quality data from external sources that were relevant for interpretation purposes. However, some data were not available for reporting or were not in line with predefined specifications. Therefore, only part of the external information could be included in the statistical analyses. Nonetheless, there was a highly significant correlation between national levels of fish consumption and mercury in hair, the strength of antismoking legislation was significantly related to urinary cotinine levels, and we were able to show indications that also urinary cadmium levels were associated with environmental quality and food quality. These results again show the potential of biomonitoring data to provide added value for (the evaluation of) evidence-informed policy making. - Highlights: • External data was collected to interpret HBM data from DEMOCOPHES. • Hg in hair could be related to fish consumption across different countries. • Urinary cotinine was related to strictness of anti-smoking legislation. • Urinary Cd was borderline significantly related to air and food quality. • Lack of comparable data among countries hampered the analysis.

54 ENVIRONMENTAL SCIENCES↗

Effects of a co-micronized composite containing palmitoylethanolamide and polydatin in an experimental model of benign prostatic hyperplasia

Palmitoylethanolamide (PEA), a fatty acid amide-signaling molecule has well-known anti-inflammatory and neuroprotective effects. Nevertheless, PEA does not possess the ability to prevent free radicals formation. Polydatin (PLD), a biological precursor of resveratrol, has antioxidant activity. A combination of PEA and PLD could, conceivably, have beneficial effects on oxidative stress produced by inflammatory processes. In the present study we investigated the effects of a co-micronized composite containing PEA and PLD (m(PEA/PLD)) in a model of testosterone-induced benign hyperplasia (BPH). BPH was provoked in rats by daily administration of testosterone propionate (3 mg/kg) for 14 days. This protocol leads to alterations in prostate morphology and increased levels of prostaglandin E2 and dihydrotestosterone as well as of 5α-reductase 1 and 5α-reductase 2 expression. Moreover, testosterone induced marked inflammation in terms of an increase in nuclear translocation of nuclear factor-κB p65 and consequently in IκB-α degradation as well as disregulation of inducible nitric oxide synthase, cyclooxygenase-2 and manganese superoxide dismutase expression and in the apoptosis pathway. Our results show, for the first time, that m(PEA/PLD) is capable of decreasing prostate weight and dihydrotestosterone production in BPH-induced rats. These effects were most likely correlated to the anti-inflammatory and apoptotic effects of m(PEA/PLD). Accordingly, these results support the view that m(PEA/PLD) should be further studied as a potent candidate for the management of BPH. - Highlights: • Chronic inflammation has emerged as a potential factor in the pathogenesis of BPH. • We evaluate the effects of m(PEA/PLD) in terms of impact on the inflammatory process and oxidative stress in BPH. • m(PEA/PLD) should be further explored as a valid candidate for the treatment of BPH.

60 APPLIED LIFE SCIENCES↗

Identification and Testing of Electric Vehicle Fast Charger Cybersecurity Mitigations

Fast-charging infrastructure for electric vehicles (EVs) is needed to enable and achieve the national goals of transitioning the vehicle fleet toward more electrification. Idaho National Laboratory, Oak Ridge National Laboratory, and the National Renewable Energy Laboratory (NREL) have jointly worked to identify, evaluate, and mitigate potential cyber-related consequences associated with fast charger systems. NREL contributed by considering cyberattack scenarios and consequences associated with integrating distributed energy resources (DERs) at fast-charging stations. The dynamic nature of fast-charger load profiles would encourage site operators to incorporate solar for energy cost reduction and energy storage for peak demand cost management at future charging facilities with multiple fast chargers at a site. These energy resources would be monitored and coordinated via a site energy management controller with data exchange between devices and local power metering infrastructure; thus, networking between devices and the design of the system becomes important in the overall cybersecurity posture. In addition, component vendors and system operators might have remote interfaces to any of these systems. It is therefore important to understand the breadth of the cyberattack surface and potential strategies to mitigate impacts. This project has focused on components and protocols expected to be found within a local charging site that includes multiple chargers and DER resources. Our methods and results are summarized in this final report.

42 ENGINEERING↗

TU-A-9A-02: Analysis of Variations in Clinical Doppler Ultrasound Peak Velocity Measurements

Purpose: Doppler ultrasound (US) peak velocity (Vmax) measurements show considerable variations due to intrinsic spectral broadening with different scanning techniques, machines and manufacturers. We developed a semi-automated Vmax estimation method and used this method to investigate the performance of a US system for clinical Doppler Vmax measurement. Methods: Semi-automated Vmax is defined as the velocity at which the computed mean spectral profile falls to within 1 background standard deviation of the background mean. GE LOGIQ E9 system with 9L and ML6-15 probes were studied with steady flow (5.3 – 12.5 ml/s) in a Gammex OPTIMIZER 1425A phantom. All Doppler spectra were acquired by 1 operator at the distal end of 5 mm angular tube using a modified clinical carotid artery protocol. Repeatability and variation of Vmax to scanning parameters and probes were analyzed and reported as percentage, i.e. (max-min)/mean. Results: Vmax estimation had good repeatability (3.1% over 6 days for 9L, and 3.6% for ML6-15). For 9L probe, varying gain, compression, scale, SV depth and length, and frequency had minimal impact on Vmax (all variations less than 4.0%). Beam steering had slightly higher influence (largest variations across flow rates were 4.9% for 9L and 6.9% for ML6-15). For both probes, Doppler angle had the greatest effect on Vmax. Percentage increase of Vmax was largely independent of actual flow rates. For Doppler angle varied from 30 to 60°, Vmax increased 24% for 9L, and 20% for ML6-15. Vmax measured by ML6-15 were lower than that by 9L at each Doppler angle with differences less than 5%. Conclusion: The proposed Vmax estimation method is shown to be a useful tool to evaluate clinical Doppler US system performance. For the tested system and probes, Doppler angle had largest impact in measured Vmax.

42 ENGINEERING↗

SU-E-T-407: Evaluation of the Stopping Power and Imaging Visibility for Iodine Based Contrast in Proton Therapy

Purpose: The purpose of this study was to investigate the difference between calculated and measured relative linear stopping power (RLSP) for contrast medium in proton therapy. Furthermore, the visibility for different concentrations in prostate phantom on orthogonal X-ray system was evaluated Methods and Materials: In prostate cancer patient, rectal balloon along with the contrast media was used to visualize the balloon position, thus facilitating the patient setup during each fraction of the uniform scanning proton treatment. There were no fiducial markers implanted in the prostate for this patient. A blue wax phantom with outer dimensions 10cm(H) x 14.5cm(L) x 10cm(W) was made in house. To hold iodine based contrast solution, a rectangular shaped hole with dimensions 7cm(H) x 8cm(L) x 4cm(W) was made inside the phantom. Organically bound 8.5% iodine based Cystografin Dilute contrast agent with molecular formula C11H9I3N2O4.C7H17NO5 was used in this study. Six solutions were prepared; each mixture of water and iodine based contrast agent at different concentrations as 0%, 5%, 10%, 20%, 30% and 50%. During computed tomographic(CT) simulation, solutions were placed together at the isocenter of CT and scanned at 120kVp using the same protocol as for prostate cancer patients. The treatment planning was done in CMS-XiO system. Multi-layer-ion-chamber (MLIC) was used to measure residual proton range. Results: The 50% concentration contrast solution was used during treatment for better visualization on orthogonal X-ray image. The measured RLSP for 5%, 10%, 20%, 30% & 50% solutions were 1.005, 1.010, 1.018, 1.023 & 1.033; and similarly calculated RLSP from XiO were 1.090, 1.135, 1.222, 1.299 & 1.448 respectively. Conclusion: The treatment planning system could overestimates the relative stopping power of contrast solution with high concentrations. It is recommended to override the contrast with measured RLSP for high atomic number based contrast solution in treatment planning for proton therapy.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-IeP2-05: Feasibility Demonstration of High-Voltage Clinical CT and Impact On X-Ray Penetration Through Metal Objects

Purpose: To demonstrate the possibility and quantify the impact of operating a clinical CT scanner at exceptionally high x-ray tube voltage for better penetration through metal objects and facilitating metal artifact reduction. Methods: We categorize metal objects according to the data corruption severeness (level of distortion and complete photon starvation fraction). To demonstrate feasibility and investigate the impact of high voltage scanning we modified a commercial GE LightSpeed VCT scanner (generator and software) to enable CT scans with x-ray tube voltages as high as 175 kVp. A 20 cm diameter water phantom with two metal rods (10 mm stainless and 25 mm titanium) and a water phantom with realistic metal object (spine cage) were used to evaluate the data corruption and image artifacts in the absence of any algorithm correction. We also performed simulations to confirm our understanding of the transmitted photon levels through metal objects with different size and composition. Results: The reconstructed images at 175 kVp still have significant dark shading artifacts, as expected since no special scatter correction or beam hardening was performed but show substantially lower noise and photon starvation than at lower kVp due to better beam penetration. Analysis of the raw data shows that the photon starved data is reduced from over 4% at 140 kVp to below 0.2% at 175 kVp. The simulations indicate that for clinically relevant titanium and stainless objects a 175 kVp tube voltage effectively avoids photon starvation. Conclusion: The use of exceptionally high tube voltage on a clinical CT system is a practical and effective solution to avoid photon starvation caused by certain metal implants. Sparse and hybrid high-voltage protocols are being considered to maintain low patient dose. This opens the door to algorithmic physics-based corrections rather than treating the data as missing and relying on missing data algorithms. Some of the authors are employees of General Electric.

60 APPLIED LIFE SCIENCES↗

Real-Time Hardware-in-the-Loop Testbed to Evaluate FLISR Implemented with OpenFMB

With the increasing complexity of the distribution smart grid architecture, algorithms such as the fault location, isolation, and service restoration (FLISR) scheme rely on robust communications that are resilient to natural and man-made adverse conditions and exhibit robustness. Existing communications infrastructure for information exchange are centralized at the distribution management system, with very little autonomy or intelligence at the grid-edge. As a first step towards achieving grid-edge self-healing, this paper aims to bridge this shortcoming by implementing a centrally coordinated rules-based FLISR scheme and integrating it with Open Field Message Bus (OpenFMB), which is a flexible publish-subscribe architecture with the potential to enable point-to-multipoint communications and is more robust and resilient to natural and man-made adverse conditions. A proof of concept is developed to validate the centrally coordinated FLISR and OpenFMB mounted on an SEL-3360 computer that interacts with a simple feeder network of five SEL-651R relays, an SEL-3530 RTAC, and a hardware-in-the-loop testbed. Results demonstrate the efficacy of this approach in enabling direct, low-latency information exchange. OpenFMB's publish-subscribe data model also opens new ways to enable grid-edge interoperability among devices of different vendors interacting with different protocols.

Sundararajan, Aditya↗

Sustainable LED Fluorescent Light Replacement Technology

Ilumisys and the National Center for Manufacturing Sciences (NCMS) partnered on a three-year project awarded by the United States (U.S.) Department of Energy (DOE), to quantify the impacts of LED lamps, incandescent lamps and fluorescent benchmark lamps over a product lifecycle – i.e. to develop a sustainable design and manufacturing strategy that addresses product manufacturing, use, recycling and disposal scenarios for LED-based lighting. Based on the knowledge gained from extensive product tear-down studies of fluorescent and screw-in lighting products, lifecycle assessment tools, and accelerated lifecycle testing protocols, an interactive Sustainable LED Design Guide has been developed to aid architectural and lighting designers and engineers in making design decisions that consider three important environmental impacts (greenhouse gas emissions, energy use and mercury emission) across all phases of the life of an LED lighting product. Critical information developed for the lifecycle analysis and product feature comparisons is the useful life of the lighting product as well as its performance. The Design Guide is available at www.ncms.org, and was developed based on operational and durability testing of a variety of lighting products including power consumption, light output, and useful life of a lamp in order to allow a more realistic comparison of lamp designs. This report describes the main project tasks, results and innovative features of the lifecycle assessment (LCA)-based design tools, and the key considerations driving the sustainable design of LED lighting systems. The Design Guide incorporates the following three novel features for efficiently evaluating LED lighting features in value-chains: Bill-of-Materials (BOM) Builder – Designers may import process data for each component and supply functional data for the product, including power, consumption, lumen output and expected useful life: Environmental Impact Review – Designs are comparable across lifecycle phases, subsystems, and environmental impact category, and can be normalized to a user-defined functional unit: Drill-down Review – These provide an in-depth look at individual lamp designs with the ability to review across subsystem or lifecycle phase.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Final Expert Meeting Report: Simplified Space Conditioning Strategies for Energy Efficient Houses

More research is needed to evaluate the level of energy efficiency and the conditions where simplified space conditioning systems will work in new and retrofitted houses. Guidance is needed on the design and installation of these systems to support a wider adoption throughout the new construction and retrofit market. The purpose of this expert meeting was to recap the current state of knowledgein this area and to provide a peer review of IBACOS's research plan for new and existing unoccupied test houses with minimized space conditioning systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗