Search NASA⌕ Search

SEARCH · Search NASA

Results for “image sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

A low-latency graph computer to identify metastable particles at the Large Hadron Collider for real-time analysis of potential dark matter signatures

Abstract Image recognition is a pervasive task in many information-processing environments. We present a solution to a difficult pattern recognition problem that lies at the heart of experimental particle physics. Future experiments with very high-intensity beams will produce a spray of thousands of particles in each beam-target or beam-beam collision. Recognizing the trajectories of these particles as they traverse layers of electronic sensors is a massive image recognition task that has never been accomplished in real time. We present a real-time processing solution that is implemented in a commercial field-programmable gate array using high-level synthesis. It is an unsupervised learning algorithm that uses techniques of graph computing. A prime application is the low-latency analysis of dark-matter signatures involving metastable charged particles that manifest as disappearing tracks.

47 OTHER INSTRUMENTATION↗

Multispectral and Thermal Imager Onboard Aerial Platforms Instrument Handbook

The MicaSense Altum imager is an off-the-shelf, synchronized multispectral and thermal camera, combined with a Global Positioning System (GPS) unit and downwelling light sensor (DLS). The Altum takes images of the land surface within its field of view (FOV) across five visible bands and one longwave infrared thermal band. The sensor records the radiance and converts it to digital numbers. Imagery is radiometrically corrected, taking into account the sensor calibration, lens distortions, vignette effects, sun angle, and atmospheric effects (scattering and absorption). The photogrammetry software Agisoft PhotoScan v 1.4 is used to align and stitch the images into a larger composite image using the technique of structure from motion image capture to construct a dense cloud and 3D model of the surface, which is used to produce a digital elevation model of the terrain surveyed and orthomosaic imagery. Land surface leaf area index, albedo, and surface skin temperature are provided for the user. The user can perform raster calculations on the imagery to produce various other vegetative indices, which are used to indicate plant health and land surface characteristics, including Normalized Difference Vegetation Index (NDVI), Green Normalized Difference Vegetation Index (GNDVI), Normalized Difference Water Index (NDWI), surface temperature, and Enhanced_vegetation_index (EVI). This code is provided with the readme file for each data set. The images have a resolution of 20-60 cm/pixel, which are subsampled to 100 cm/pixel.

47 OTHER INSTRUMENTATION↗

Assessment of the Short-Term Radiometric Stability between Terra MODIS and Landsat 7 ETM+ Sensors

The Landsat 7 (L7) Enhanced Thematic Mapper (ETM+) sensor was launched on April 15th, 1999 and has been in operation for over nine years. It has six reflective solar spectral bands located in the visible and shortwave infrared part of the electromagnetic spectrum (0.5 - 2.5 micron) at a spatial resolution of 30 m. The on-board calibrators are used to monitor the on-orbit sensor system changes. The ETM+ performs solar calibrations using on-board Full Aperture Solar Calibrator (FASC) and the Partial Aperture Solar Calibrator (PASC). The Internal Calibrator Lamp (IC) lamps, a blackbody and shutter optics constitute the on-orbit calibration mechanism for ETM+. On 31 May 2003, a malfunction of the scan-line corrector (SLC) mirror assembly resulted in the loss of approximately 22% of the normal scene area. The missing data affects most of the image with scan gaps varying in width from one pixel or less near the centre of the image to 14 pixels along the east and west edges of the image, creating a wedge-shaped pattern. However, the SLC failure has no impacts on the radiometric performance of the valid pixels. On December 18, 1999, the Moderate Resolution Imaging Spectroradiometer (MODIS) Proto-Flight Model (PFM) was launched on-board the NASA's EOS Terra spacecraft. Terra MODIS has 36 spectral bands with wavelengths ranging from 0.41 to 14.5 micron and collects data over a wide field of view angle (+/-55 deg) at three nadir spatial resolutions of 250 m, 500 in 1 km for bands 1 to 2, 3 to 7, and 8 to 36, respectively. It has 20 reflective solar bands (RSB) with spectral wavelengths from 0.41 to 2.1 micron. The RSB radiometric calibration is performed by using on-board solar diffuser (SD), solar diffuser stability monitor (SDSM), space-view (SV), and spectro-radiometric calibration assembly (SRCA). Through the SV port, periodic lunar observations are used to track radiometric response changes at different angles of incidence (AOI) of the scan mirror. As a part of the AM Constellation satellites, Terra MODIS flies approximately 30 minutes behind L7 ETM+ in the same orbit. The orbit of L7 is repetitive, circular, sunsynchronous, and near polar at a nominal altitude of 705 km (438 miles) at the Equator. The spacecraft crosses the Equator from north to south on a descending node between 10:00 AM and 10:15 AM. Circling the Earth at 7.5 km/sec, each orbit takes nearly 99 minutes. The spacecraft completes just over 14 orbits per day, covering the entire Earth between 81 degrees north and south latitude every 16 days. The longest continuous imaging swath that L7 sensor can collect is for a 14-minute subinterval contact period which is equivalent to 35 full WRS-2 scenes. On the other hand, Terra can provide the entire corresponding orbit with wider swath at any given ETM+ collection without contact time limitation. There are six spectral matching band pairs between MODIS (bands 3, 4, 1, 2, 6, 7) and ETM+ (bands 1, 2, 3, 4, 5, 7) sensor. MODIS has narrower spectral responses than ETM+ in all the bands. A short-term radiometric stability was evaluated using continuous ETM+ scenes within the contact period and the corresponding half orbit MODIS scenes. The near simultaneous earth observations (SNO) were limited by the smaller swath size of ETM+ (187 km) as compared to MODIS (2330 km). Two sets of continuous granules for MODIS and ETM+ were selected and mosaiced based on pixel geolocation information for non cloudy pixels over the North American continent. The Top-of- Atmosphere (TOA) reflectances were computed for the spectrally matching bands between ETM+ and MODIS over the regions of interest (ROI). The matching pixel pairs were aggregated from a finer to a coarser pixel resolution and the TOA reflectance values covering a wide dynamic range of the sensors were compared and analyzed. Considering the uncertainties of the absolute calibration of the both sensors, radiometric stability was verified for the band pairs. The Railroad Valley Playa, Nada (RVPN) was included in the path of this continuous orbit, which served as a verification point between the shortterm and the long-term trending results from previous studies. This work focuses on monitoring the short-term on-orbit stability of MODIS and the ETM+ RSB. It also provides an assessment of the absolute calibration differences between the two sensors over their wide dynamic ranges.

Choi, Taeyoung↗

Intercomparison of MODIS AQUA and VIIRS I-Band Fires and Emissions in an Agricultural Landscape - Implications for Air Pollution Research

Quantifying emissions from crop residue burning is crucial as it is a significant source of air pollution. In this study, we first compared the fire products from two different sensors, the Visible Infrared Imaging Radiometer Suite (VIIRS) 375 m active fire product (VNP14IMG) and Moderate Resolution Imaging Spectroradiometer (MODIS) 1 km fire product (MCD14ML) in an agricultural landscape, Punjab, India. We then performed an intercomparison of three different approaches for estimating total particulate matter (TPM) emissions which includes the fire radiative power (FRP) based approach using VIIRS and MODIS data, the Global Fire Emissions Database (GFED) burnt area emissions and a bottom-up emissions approach involving agricultural census data. Results revealed that VIIRS detected fires were higher by a factor of 4.8 compared to MODIS Aqua and Terra sensors. Further, VIIRS detected fires were higher by a factor of 6.5 than Aqua. The mean monthly MODIS Aqua FRP was found to be higher than the VIIRS FRP; however, the sum of FRP from VIIRS was higher than MODIS data due to the large number of fires detected by the VIIRS. Besides, the VIIRS sum of FRP was 2.5 times more than the MODIS sum of FRP. MODIS and VIIRS monthly FRP data were found to be strongly correlated (r2 = 0.98). The bottom-up approach suggested TPM emissions in the range of 88.19-91.19 Gg compared to 42.0-61.71 Gg, 42.59-58.75 Gg and 93.98-111.72 Gg using the GFED, MODIS FRP, and VIIRS FRP based approaches, respectively. Of the different approaches, VIIRS FRP TPM emissions were highest. Since VIIRS data are only available since 2012 compared to MODIS Aqua data which have been available since May 2002, a prediction model combining MODIS and VIIRS FRP was derived to obtain potential TPM emissions from 2003-2016. The results suggested a range of 2.56-63.66 (Gg) TPM emissions per month, with the highest crop residue emissions during November of each year. Our results on TPM emissions for seasonality matched the ground-based data from the literature. As a mitigation option, stringent policy measures are recommended to curtail agricultural residue burning in the study area.

Global Fire Emissions Database (GFED)↗

The iQID Camera: An Ionizing-Radiation Quantum Imaging Detector

We have developed and tested a novel, ionizing-radiation Quantum Imaging Detector (iQID). This scintillation-based detector was originally developed as a high-resolution gamma-ray imager, called BazookaSPECT, for use in single-photon emission computed tomography (SPECT). Recently, we have investigated the detectors response and imaging potential with other forms of ionizing radiation including alpha, neutron, beta, and fission fragment particles. The detector’s response to a broad range of ionizing radiation has prompted its new title. The principle operation of the iQID camera involves coupling a scintillator to an image intensifier. The scintillation light generated particle interactions is optically amplified by the intensifier and then re-imaged onto a CCD/CMOS camera sensor. The intensifier provides sufficient optical gain that practically any CCD/CMOS camera can be used to image ionizing radiation. Individual particles are identified and their spatial position (to sub-pixel accuracy) and energy are estimated on an event-by-event basis in real time using image analysis algorithms on high-performance graphics processing hardware. Distinguishing features of the iQID camera include portability, large active areas, high sensitivity, and high spatial resolution (tens of microns). Although modest, iQID has energy resolution that is sufficient to discrimate between particles. Additionally, spatial features of individual events can be used for particle discrimination. An important iQID imaging application that has recently been developed is single-particle, real-time digital autoradiography. In conclusion, we present the latest results and discuss potential applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated Verification of Spatial Resolution in Remotely Sensed Imagery

Image spatial resolution characteristics can vary widely among sources. In the case of aerial-based imaging systems, the image spatial resolution characteristics can even vary between acquisitions. In these systems, aircraft altitude, speed, and sensor look angle all affect image spatial resolution. Image spatial resolution needs to be verified with estimators that include the ground sample distance (GSD), the modulation transfer function (MTF), and the relative edge response (RER), all of which are key components of image quality, along with signal-to-noise ratio (SNR) and dynamic range. Knowledge of spatial resolution parameters is important to determine if features of interest are distinguishable in imagery or associated products, and to develop image restoration algorithms. An automated Spatial Resolution Verification Tool (SRVT) was developed to rapidly determine the spatial resolution characteristics of remotely sensed aerial and satellite imagery. Most current methods for assessing spatial resolution characteristics of imagery rely on pre-deployed engineered targets and are performed only at selected times within preselected scenes. The SRVT addresses these insufficiencies by finding uniform, high-contrast edges from urban scenes and then using these edges to determine standard estimators of spatial resolution, such as the MTF and the RER. The SRVT was developed using the MATLAB programming language and environment. This automated software algorithm assesses every image in an acquired data set, using edges found within each image, and in many cases eliminating the need for dedicated edge targets. The SRVT automatically identifies high-contrast, uniform edges and calculates the MTF and RER of each image, and when possible, within sections of an image, so that the variation of spatial resolution characteristics across the image can be analyzed. The automated algorithm is capable of quickly verifying the spatial resolution quality of all images within a data set, enabling the appropriate use of those images in a number of applications.

Davis, Bruce↗

Determining True Sensor Spatial Resolution of Very High Resolution Optical Imagery

Some satellite data is delivered in images with gridded pixels. This gridded pixel size is often assumed to be the spatial resolution of the satellite sensor; however, this is not always the case. An image can be grided to any arbitrary pixel size, but the sensor resolution will remain constant. For example, an image with a pixel grid size much smaller than the sensor resolution will appear blurry along what should be sharp transitions. This discrepancy between an image’s pixel size and true sensor spatial resolution can be the source of much confusion and even misinformation among data users, which may lead them to waste time and resources on using images that do not suit their spatial resolution needs. This presentation will highlight our evaluation of the true spatial resolution of various government and commercial images in the pixel size range of 0.3 m to 60 m. Images evaluated include ESA’s Sentinel-2 (60 m, 20 m, 10 m pixels), USGS’s Landsat 8/9 (30 m & 15 m pixels), Planet’s SuperDoves (3 m pixels), BlackSky’s Globals (~1 m pixels), and the optical bands of Maxar’s WorldView-2 (2.4 m – 0.41 m pixels) and WorldView-3 (1.38 m – 0.31 m pixels). Our evaluation of true sensor spatial resolution, or ‘footprint size’ is based on the sensor’s line spread function (LSF). We calculate the width at half the height of the LSF to find the full width at half maximum (FWHM). The FWHM is how we report sensor spatial resolution. Different objects are examined for constructing the LSF depending on the sensor spatial resolution. Coarser resolution sensors in this evaluation such as Sentinel-2 and Landsat 8/9 are examined at bridges over a dark water background. The bright bridge acts as a line impulse, giving a sensor’s line spread function (LSF) in one direction. Additionally, we simulate the impacts of bridge width on the apparent LSF to obtain a true LSF without the effects of bridge width for these sensors. Finer resolution sensors will image the irregularities in bridges such as trusses, sidewalks, and in some cases painted lines, interfering with the LSF construction. Instead, these sensors are evaluated at large (60 m – 140 m) black and white checkerboards known as Cal/Val sites. At these locations, the image’s transition from black to white is extracted as an edge spread function (ESF). We calculate the derivative of this ESF to obtain the sensor’s LSF. From there, we find the FWHM as we do for the coarser resolution images. With the FWHM and pixel size, we determine how over- or under-sampled the images are. When the ratio of a sensor’s spatial resolution and the gridded image’s pixel size is less than 1, the image is considered under-sampled. In this case, each pixel’s information is unique but only a portion of that pixel’s ground area has been measured. On the other side, if the ratio is greater than 1, the image is considered over-sampled. That is, each pixel’s information is sourced from within the ground extent of the pixel and some extent outside additionally. We will show the true spatial resolution and the extent of over-/under-sampling in the imagery from ESA’s Sentinel-2 (60 m, 20 m, 10 m pixels), USGS’s Landsat 8/9 (30 m & 15 m pixels), Planet’s SuperDoves (3 m pixels), BlackSky’s Globals (~1 m pixels), and the optical bands of Maxar’s WorldView-2 (2.4 m – 0.41 m pixels) and WorldView-3 (1.38 m – 0.31 m pixels).

Alana Semple↗

Superconducting Digital Multiplexers for Sensor Arrays

Arrays of cryogenic microbolometers and other cryogenic detectors are being developed for infrared imaging. If the signal from each sensor is amplified, multiplexed, and digitized using superconducting electronics, then this data can be efficiently read out to ambient temperature with a minimum of noise and thermal load. HYPRES is developing an integrated system based on SQUID amplifiers, a high-resolution analog-to-digital converter (ADC) based on RSFQ (rapid single flux quantum) logic, and a clocked RSFQ multiplexer. The ADC and SQUIDs have already been demonstrated for other projects, so this paper will focus on new results of a digital multiplexer. Several test circuits have been fabricated using Nb Josephson technology and are about to be tested at T = 4.2 K, with a more complete prototype in preparation.

Kadin, Alan M.↗

SSC Geopositional Assessment of an AWiFS Image Orthorectified Product

The geopositional accuracy of an AWiFS (Advanced Wide Field Sensor) orthorectified product was evaluated. Specifically, the image products were acquired by the Indian Remote Sensing Resourcesat-1 satellite, then orthorectified by GeoEye . Analysis was performed using DOQs (digital orthophoto quadrangles) and other reference sources of similar accuracy. A total of six AWiFS images were characterized. These images were acquired over the continental United States from June through September 2005. The images were equally divided between the two AWiFS cameras. Forty to fifty check points were collected manually per scene and analyzed to determine overall circular error, estimates of horizontal bias, and other systematic errors.

Kenton, Ross↗

Imager-to-Radiometer In-flight Cross Calibration: RSP Radiometric Comparison with Airborne and Satellite Sensors

This work develops a method to compare the radiometric calibration between a radiometer and imagers hosted on aircraft and satellites. The radiometer is the airborne Research Scanning Polarimeter (RSP), which takes multi-angle, photo-polarimetric measurements in several spectral channels. The RSP measurements used in this work were coincident with measurements made by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), which was on the same aircraft. These airborne measurements were also coincident with an overpass of the Landsat 8 Operational Land Imager (OLI). First we compare the RSP and OLI radiance measurements to AVIRIS since the spectral response of the multispectral instruments can be used to synthesize a spectrally equivalent signal from the imaging spectrometer data. We then explore a method that uses AVIRIS as a transfer between RSP and OLI to show that radiometric traceability of a satellite-based imager can be used to calibrate a radiometer despite differences in spectral channel sensitivities. This calibration transfer shows agreement within the uncertainty of both the various instruments for most spectral channels.

calibrating↗

Longitudinally Jointed Edge-wise Compression Honeycomb Composite Sandwich Coupon Testing and FE Analysis: Three Methods of Strain Measurement, and Comparison

Three means (i.e., typical foil strain gages, fiber optic sensors, and a digital image correlation (DIC) system) were implemented to measure strains on the back and front surfaces of a longitudinally jointed curved test article subjected to edge-wise compression testing, at NASA Goddard Space Flight Center, according to ASTM C364. The Pre-test finite element analysis (FEA) was conducted to assess ultimate failure load and predict strain distribution pattern throughout the test coupon. The predicted strain pattern contours were then utilized as guidelines for installing the strain measurement instrumentations. The strain gages and fiber optic sensors were bonded on the specimen at locations with nearly the same strain values, as close as possible to each other, so that, comparisons between the measured strains by strain gages and fiber optic sensors, as well as the DIC system are justified. The test article was loaded to failure (at approximately 38 kips), at the strain value of approximately 10,000mu epsilon As a part of this study, the validity of the measured strains by fiber optic sensors is examined against the strain gage and DIC data, and also will be compared with FEA predictions.

Farrokh, Babak↗

Broadband imaging with one planar diffractive lens

We demonstrate imaging over the visible band using a single planar diffractive lens. This is enabled via multi-level diffractive optics that is designed to focus over a broad wavelength range, which we refer to as an achromatic diffractive lens (ADL). We designed, fabricated and characterized two ADLs with numerical apertures of 0.05 and 0.18. Diffraction-limited focusing is demonstrated for the NA = 0.05 lens with measured focusing efficiency of over 40% across the entire visible spectrum (450 nm to 750 nm). We characterized the lenses with a monochromatic and a color CMOS sensor, and demonstrated video imaging under natural sunlight and other broadband illumination conditions. We use rigorous electromagnetic simulations to emphasize that ADLs can achieve high NA (0.9) and large operating bandwidth (300 nm in the visible spectrum), a combination of metrics that have so far eluded other flat-lens technologies such as metalenses. Here, these planar diffractive lenses can be cost-effectively manufactured over large areas and thereby, can enable the wide adoption of flat, low-cost lenses for a variety of imaging applications.

47 OTHER INSTRUMENTATION↗

ATP compartmentation in plastids and cytosol of Arabidopsis thaliana revealed by fluorescent protein sensing

Matching ATP:NADPH provision and consumption in the chloroplast is a prerequisite for efficient photosynthesis. In terms of ATP:NADPH ratio, the amount of ATP generated from the linear electron flow does not meet the demand of the Calvin–Benson–Bassham (CBB) cycle. Several different mechanisms to increase ATP availability have evolved, including cyclic electron flow in higher plants and the direct import of mitochondrial-derived ATP in diatoms. By imaging a fluorescent ATP sensor protein expressed in living Arabidopsis thaliana seedlings, we found that MgATP 2- concentrations were lower in the stroma of mature chloroplasts than in the cytosol, and exogenous ATP was able to enter chloroplasts isolated from 4- and 5-day-old seedlings, but not chloroplasts isolated from 10- or 20-day-old photosynthetic tissues. This observation is in line with the previous finding that the expression of chloroplast nucleotide transporters (NTTs) in Arabidopsis mesophyll is limited to very young seedlings. Employing a combination of photosynthetic and respiratory inhibitors with compartment-specific imaging of ATP, we corroborate the dependency of stromal ATP production on mitochondrial dissipation of photosynthetic reductant. Our data suggest that, during illumination, the provision and consumption of ATP:NADPH in chloroplasts can be balanced by exporting excess reductants rather than importing ATP from the cytosol.

59 BASIC BIOLOGICAL SCIENCES↗

Portable Remote Imaging Spectrometer (PRISM): Laboratory and Field Calibration

We report the characteristics of the Portable Remote Imaging Spectrometer, an airborne sensor specifically designed for the challenges of coastal ocean research. PRISM has high signal to noise ratio and uniformity, as well as low polarization sensitivity. Acquisition of high quality data has been demonstrated with the first engineering flight.

imaging spectrometer↗

Adaptive Cross-correlation Algorithm and Experiment of Extended Scene Shack-Hartmann Wavefront Sensing

We have developed a new, adaptive cross-correlation (ACC) algorithm to estimate with high accuracy the shift as large as several pixels in two extended-scene images captured by a Shack-Hartmann wavefront sensor (SH-WFS). It determines the positions of all of the extended-scene image cells relative to a reference cell using an FFT-based iterative image shifting algorithm. It works with both point-source spot images as well as extended scene images. We have also set up a testbed for extended0scene SH-WFS, and tested the ACC algorithm with the measured data of both point-source and extended-scene images. In this paper we describe our algorithm and present out experimental results.

Shack - Hartmann sensor↗

Detection of Anomalies in the UV/Vis Reflectances from the Ozone Monitoring Instrument

Various instrumental or geophysical artifacts, such as saturation, stray light, or obstruction of light (either coming from the instrument or related to solar eclipses), negatively impact satellite measured ultraviolet and visible Earthshine radiance spectra and downstream retrievals of atmospheric and surface properties derived from these spectra. In addition, excessive noise such as from cosmic ray impacts, prevalent within the South Atlantic Anomaly, can also degrade satellite radiance measurements. Saturation specifically pertains to observations of very bright surfaces such as sun glint over open water or thick clouds. When saturation occurs, additional photoelectric charge generated at the saturated pixel may overflow to pixels adjacent to a saturated area and be reflected as a distorted image in the final sensor output.When these effects cannot be corrected to an acceptable level for science quality retrievals, flagging of the affected pixels is indicated. Here, we introduce a straightforward detection method that is based on the correlation, r, between the observed Earthshine radiance and solar irradiance spectraover a 10 nm-spectral range; our Decorrelation Index (DI for brevity) is simply defined as DI=1-r. DI increases with anomalous additive effects or excessive noise in either radiances, the most likely cause indata from theOzone Monitoring Instrument (OMI),or irradiances. DI is relatively straight-forward to use and interpret and can be 20computed for different wavelength intervals. We developed a set of DIs for two spectral channelsof the OMI, a hyperspectral pushbroom imaging spectrometer. For each OMI spatial measurement, we define 14 wavelength-dependent DIs within the OMI visible channel (350-498 nm) and 6 DIs in its ultraviolet 2 (UV2) channel (310-370 nm). As defined, DIs reflect a continuous range of deviations of observed spectra from the reference irradiance spectrum that are complementary to the binary Saturation Possibility Warning (SPW) flags currently provided for each individual spectral/spatial pixel in the OMI radiance data set. Smaller values of DI are also caused by a number of geophysical factors; this allows one to obtain interesting physical results on the global distribution of spectral variations.

Space sensor↗

Fabrication and Calibration of FORTIS

The Johns Hopkins University sounding rocket group is entering the final fabrication phase of the Far-ultraviolet Off Rowland-circle Telescope for Imaging and Spectroscopy (FORTIS); a sounding rocket borne multi-object spectro-telescope designed to provide spectral coverage of 43 separate targets in the 900 - 1800 Angstrom bandpass over a 30' x 30' field-of-view. Using "on-the-fly" target acquisition and spectral multiplexing enabled by a GSFC microshutter array, FORTIS will be capable of observing the brightest regions in the far-UV of nearby low redshift (z approximately 0.002 - 0.02) star forming galaxies to search for Lyman alpha escape, and to measure the local gas-to-dust ratio. A large area (approximately 45 mm x 170 mm) microchannel plate detector built by Sensor Sciences provides an imaging channel for targeting flanked by two redundant spectral outrigger channels. The grating is ruled directly onto the secondary mirror to increase efficiency. In this paper, we discuss the recent progress made in the development and fabrication of FORTIS, as well as the results of early calibration and characterization of our hardware, including mirror/grating measurements, detector performance, and early operational tests of the micro shutter arrays.

Fleming, Brian T.↗

An Overview of the Landsat Data Continuity Mission

The advent of the Landsat Data Continuity Mission (LDCM), currently with a launch readiness date of December, 2012, will see evolutionary changes in the Landsat data products available from the U.S. Geological Survey (USGS) Earth Resources Observation and Science (EROS) Center. The USGS initiated a revolution in 2009 when EROS began distributing Landsat data products at no cost to requestors in contrast to the past practice of charging the cost of fulfilling a request; that is, charging $600 per Landsat scene. To implement this drastic change, EROS terminated data processing options for requestors and began to produce all data products using a consistent processing recipe. EROS plans to continue this practice for the LDCM and will required new algorithms to process data from the LDCM sensors. All previous Landsat satellites flew multispectral scanners to collect image data of the global land surface. Additionally, Landsats 4, 5, and 7 flew sensors that acquired imagery for both reflective spectral bands and a single thermal band. In contrast, the LDCM will carry two pushbroom sensors; the Operational Land Imager (OLI) for reflective spectral bands and the Thermal InfraRed Sensor (TIRS) for two thermal bands. EROS is developing the ground data processing system that will both calibrate and correct the data from the thousands of detectors employed by the pushbroom sensors and that will also combine the data from the two sensors to create a single data product with registered data for all of the OLI and TIRS bands.

Irons, James R.↗