Search NASA⌕ Search

SEARCH · Search NASA

Results for “load changes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Damage Modeling of Solid Oxide Fuel Cells Accounting for Redox Effects

This work applies a multiscale mechanistic damage model developed for brittle ceramics and implemented in commercial finite element (FE) packages via user subroutines to study progressive damage in solid oxide fuel cells (SOFC) subjected to thermomechanical loading under normal operating and shutdown conditions including redox effects. The damage model captures the micromechanics of stiffness reduction due to material porosity change and microcracking and integrates the as-obtained stiffness reduction law into a continuum damage mechanics (CDM) formulation for the evolution of microcracks up to fracture. The volumetric “swelling” that occurs during redox is treated in constitutive modeling similarly to thermal expansion, but swelling strains are irreversible. Furthermore, this damage model was first validated through predictions of strength and stress-strain response for the SOFC electrode materials. Next, it has been applied to predict the potential for degradation in a generic planar SOFC stack with large active area cells. Multicell stack models were simulated in both co-flow and counter-flow configurations. In addition, a constant temperature redox cycle was also simulated to capture overall cell electrode damage due to volumetric swelling of the nickel (Ni)-based anode in the anode-supported cells.

25 ENERGY STORAGE↗

Geographic Visualization of Power-Grid Dynamics

The visualization enables the simulation analyst to see changes in the frequency through time and space. With this technology, the analyst has a bird's eye view of the frequency at loads and generators as the simulated power system responds to the loss of a generator, spikes in load, and other contingencies. The significance of a contingency to the operation of an electrical power system depends critically on how the resulting tansients evolve in time and space. Consequently, these dynamic events can only be understood when seen in their proper geographic context. this understanding is indispensable to engineers working on the next generation of distributed sensing and control systems for the smart grid. By making possible a natural and intuitive presentation of dynamic behavior, our new visualization technology is a situational-awareness tool for power-system engineers.

Sukumar, SreenivasR.↗

Learning reference governor for cycle-to-cycle combustion control with misfire avoidance in spark-ignition engines at high exhaust gas recirculation–diluted conditions

Cycle-to-cycle feedback control is employed to achieve optimal combustion phasing while maintaining high levels of exhaust gas recirculation by adjusting the spark advance and the exhaust gas recirculation valve position. The control development is based on a control-oriented model that captures the effects of throttle position, exhaust gas recirculation valve position, and spark timing on the combustion phasing. Under the assumption that in-cylinder pressure information is available, an adaptive extended Kalman filter approach is used to estimate the exhaust gas recirculation rate into the intake manifold based on combustion phasing measurements. The estimation algorithm is adaptive since the cycle-to-cycle combustion variability (output covariance) is not known a priori and changes with operating conditions. A linear quadratic regulator controller is designed to maintain optimal combustion phasing while maximizing exhaust gas recirculation levels during load transients coming from throttle tip-in and tip-out commands from the driver. During throttle tip-outs, however, a combination of a high exhaust gas recirculation rate and an overly advanced spark, product of the dynamic response of the system, generates a sequence of misfire events. In this work, an explicit reference governor is used as an add-on scheme to the closed-loop system in order to avoid the violation of the misfire limit. The reference governor is enhanced with model-free learning which enables it to avoid misfires after a learning phase. Experimental results are reported which illustrate the potential of the proposed control strategy for achieving an optimal combustion process during highly diluted conditions for improving fuel efficiency.

42 ENGINEERING↗

The Impact Of The MCU Life Extension Solvent On Sludge Batch 8 Projected Operating Windows

As a part of the Actinide Removal Process (ARP)/Modular Caustic Side Solvent Extraction Unit (MCU) Life Extension Project, a next generation solvent (NGS) and a new strip acid will be deployed. The strip acid will be changed from dilute nitric acid to dilute boric acid (0.01 M). Because of these changes, experimental testing or evaluations with the next generation solvent are required to determine the impact of these changes (if any) to Chemical Process Cell (CPC) activities, glass formulation strategies, and melter operations at the Defense Waste Processing Facility (DWPF). The introduction of the dilute (0.01 M) boric acid stream into the DWPF flowsheet has a potential impact on glass formulation and frit development efforts since B 2 O 3 is a major oxide in frits developed for DWPF. Prior knowledge of this stream can be accounted for during frit development efforts but that was not the case for Sludge Batch 8 (SB8). Frit 803 has already been recommended and procured for SB8 processing; altering the frit to account for the incoming boron from the strip effluent (SE) is not an option for SB8. Therefore, the operational robustness of Frit 803 to the introduction of SE including its compositional tolerances (i.e., up to 0.0125M boric acid) is of interest and was the focus of this study. The primary question to be addressed in the current study was: What is the impact (if any) on the projected operating windows for the Frit 803 - SB8 flowsheet to additions of B 2 O 3 from the SE in the Sludge Receipt and Adjustment Tank (SRAT)? More specifically, will Frit 803 be robust to the potential compositional changes occurring in the SRAT due to sludge variation, varying additions of ARP and/or the introduction of SE by providing access to waste loadings (WLs) of interest to DWPF? The Measurement Acceptability Region (MAR) results indicate there is very little, if any, impact on the projected operating windows for the Frit 803 - SB8 system regardless of the presence or absence of ARP and SE (up to 2 wt% B 2 O 3 contained in the SRAT and up to 2000 gallons of ARP). It should be noted that 0.95 wt% B 2 O 3 is the nominal projected concentration in the SRAT based on a 0.0125M boric acid flowsheet with 70,000 liters of SE being added to the SRAT.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Uncertainty Quantification Techniques for Sensor Calibration Monitoring in Nuclear Power Plants

This report describes the status of ongoing research towards the development of advanced algorithms for online calibration monitoring. The objective of this research is to develop the next generation of online monitoring technologies for sensor calibration interval extension and signal validation in operating and new reactors. These advances are expected to improve the safety and reliability of current and planned nuclear power systems as a result of higher accuracies and increased reliability of sensors used to monitor key parameters. The focus of this report is on documenting the outcomes of the first phase of R&D under this project, which addressed approaches to uncertainty quantification (UQ) in online monitoring that are data-driven, and can therefore adjust estimates of uncertainty as measurement conditions change. Such data-driven approaches to UQ are necessary to address changing plant conditions, for example, as nuclear power plants experience transients, or as next-generation small modular reactors (SMR) operate in load-following conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Uncertainty Quantification Techniques for Sensor Calibration Monitoring in Nuclear Power Plants

This report describes research towards the development of advanced algorithms for online calibration monitoring. The objective of this research is to develop the next generation of online monitoring technologies for sensor calibration interval extension and signal validation in operating and new reactors. These advances are expected to improve the safety and reliability of current and planned nuclear power systems as a result of higher accuracies and increased reliability of sensors used to monitor key parameters. The focus of this report is on documenting the outcomes of the first phase of R&D under this project, which addressed approaches to uncertainty quantification (UQ) in online monitoring that are data-driven, and can therefore adjust estimates of uncertainty as measurement conditions change. Such data-driven approaches to UQ are necessary to address changing plant conditions, for example, as nuclear power plants experience transients, or as next-generation small modular reactors (SMR) operate in load-following conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Absorbing the Sun: Operational Practices and Balancing Reserves in Florida's Municipal Utilities

The Florida Reliability Coordinating Council (FRCC) power system is comprised of multiple balancing authorities ranging in size from Gainesville Regional Utilities (GRU) with a 2019 summer net firm demand of 429 MW to Florida Power & Light with a 2019 summer net firm demand of 22,510 MW; and including cooperative, municipal, and investor-owned utilities. As all of these balancing authorities are and have plants to continue installing significant quantities of utility-scale solar photovoltaics, one relevant question is how much operating reserves they will need to hold as solar penetrations increase. While there are estimates of how regulating and flexibility reserve requirements change with solar penetration, the literature almost exclusively focuses on large balancing authorities with sub-hourly dispatch. In this work we analyze how reserve needs change not only with solar photovoltaic penetration, but also balancing authority size and operational practices. We find that, measured as a fraction of load, smaller balancing authorities with less frequent load and solar forecasts and less frequent dispatch need more reserves. Such utilities' reserve needs also increase more with increasing solar deployment as compared to larger or more frequently dispatched balancing authorities. These impacts are most acute for GRU. We find that moving from day-ahead to hour-ahead load and solar forecasting and system dispatch could enable GRU to incorporate 32% solar generation with median reserves at 20% instead of 60% of load; and that median reserve needs could drop further to about 10% of load if Florida's municipal utilities formed a reserve sharing group and moved to sub-hourly dispatch.

14 SOLAR ENERGY↗

Smart Ventilation Controls for Occupancy and Auxiliary Fan Use Across U.S. Climates

Smart Ventilation has been developed as a way to reduce the energy associated with ventilation by changing when ventilation happens and how much ventilation occurs at any given time. In high performance buildings with low envelope and appliance related loads, ventilation is becoming a bigger part of the total building energy use and needs to be addressed if performance targets are to be met. This work explores the development and performance of smart ventilation controls based on occupancy and auxiliary fan operation that provide annual dwelling unit ventilation equivalence to ASHRAE Standard 62.2-2016. A prototype high performance home compliant with U.S. DOE Building America Zero Energy Ready program requirements was simulated using the REGCAP tool with and without smart controls across 15 U.S. DOE climate zones. Balanced and unbalanced IAQ fans were independently simulated, and all smart controlled fans had airflows double the reference 62.2-2016 airflow. Three idealized occupancy patterns were examined: 1st shift (a typical daily work/school absence), an extended 1st shift with more time spent out of the home evenings and weekends and 3rd shift (night work). The Occupancy controller turns the IAQ fan off during unoccupied periods, and it resumes ventilation upon their return. While unoccupied, contaminants are allowed to accumulate in the space, because occupants are not exposed to these contaminants. When occupants return home, they are exposed to these higher contaminant concentrations, and the controller increases the ventilation rate sufficiently to ensure equivalence with a continuous IAQ fan. Accounting for pollutant emissions that occur during unoccupied periods (as required by ASHRAE 62.2-2016), sharply distinguishes our occupancy controls from past Demand Controlled Ventilation systems. This new accounting method results in equivalent contaminant exposure, as well as lower reductions in average ventilation rates and lower energy savings. Smart controls were demonstrated that saved HVAC energy (i.e., avoided heating/cooling load, as well as fan energy)—averaging between 6 and 46% of ventilation-related energy use depending on the control strategy and occupancy pattern assumptions. The greatest savings were in the combined Auxiliary Fan + Occupancy control. Energy savings increased with climate heating demand and longer unoccupied time periods. The 3rd shift occupancy pattern had better performance, due to the thermal benefit of reducing the ventilation rate during the cold nighttime hours. This same effect provided a cooling energy benefit in hotter locations for the 1st shift. Overall, savings from occupancy-based smart controls were low, because of the recovery period required after occupants return home, during which the airflow is double the 62.2 reference. This recovery is required to maintain equivalence with the ASHRAE standard. Occupancy-based control performance was improved when combined with sensing auxiliary fans and when providing a pre-occupancy flush out of one- or two-hours. Performance was similarly improved if the ASHRAE Standard were to recognize that pollutant emissions are lower during unoccupied periods, iii allowing a lower target ventilation rate during unoccupied periods (not currently in the standard) (see Full vs. Half AEQ in this report). Finally, over-sized unbalanced fans that are cycled on-and-off by a smart controller (or timer) were found to substantially increase annual average air exchange and energy use relative to a continuous unbalanced fan due to the effects of superposition with natural infiltration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Framework for Characterizing Strain in the Vicinity of Leaky Reservoirs

The identification of leaks in the vicinity of reservoirs is critical to determining the feasibility of long-term geologic storage of CO2, methane, wastewater and other fluids. We have established a series of basic reservoir leakage scenarios and performed numerical analysis to characterize the associated pressure and strain fields created from injection into these leaky reservoir settings, as well from ambient loads, such as barometric pressure and earth tides. The end-member conceptual models evaluated include injection and ambient loads applied to: 1) a thin, horizontal layer with no leakage pathways (baseline), 2) a thin layer with a vertical conduit to the surface (e.g., a leaky fault or abandoned well) and 3) a thin layer with a conduit to an overlying aquifer. The pressure and strain fields are sensitive to the reservoir and confining unit geometry, material properties, the distribution, composition and compressibility of the pore fluid and the type of applied load (e.g., constant vs. cyclical injection, barometric pressure fluctuations, earth tides, etc.). Initial results from the numerical analyses indicate that an induced pressure change of 1 MPa in a formation at 1 km depth with a Young’s modulus of 10 GPa is sufficient to create vertical and horizontal strain signals as high as 2 με at a depth of 100 m. The signals predicted from leaky conditions compared to an intact reservoir differ by as much as 0.2 με in magnitude and evolve at different rates. We have developed instruments capable of measuring vertical and horizontal strain at a resolution of better than 5 nε and have recorded repeatable strain signals at 30 m depth in response to wastewater injection into the Avant field in Oklahoma. Based on these findings, strain signals predicted in the shallow subsurface (< 100 m) with numerical analysis are expected to be measurable, and this signal may be inverted to characterize the location and magnitude of leaks, as well as to characterize the geometry and hydromechanical properties of the formation and overlying confining units. This suggests that shallow strain measurements could be a cost effective method for characterizing and monitoring gas storage projects.

Robert, Moak↗

Conceptual Designs for Irradiation Creep Testing of SiC in HFIR

Understanding irradiation creep of nuclear fuel cladding is important to properly size the initial fuel-cladding gap and understand when pellet-cladding contact is expected to occur due to a combination of fuel swelling and cladding creep-down. Irradiation creep also plays a role in relaxing stresses that develop in-pile. Silicon carbide fiber–reinforced silicon carbide matrix (SiC/SiC) composites are the leading long-term accident-tolerant fuel cladding concept for light-water reactors (LWRs). Although some limited data are available regarding irradiation creep of the individual constituents (fibers, matrix), data regarding irradiation creep of SiC/SiC composites are currently insufficient. Additional data regarding irradiation creep compliance and the rupture lifetime (combination of creep and slow crack growth) are needed to understand material limitations. This work describes the design and development of two irradiation vehicles that are being pursued for testing SiC/SiC concepts in the High Flux Isotope Reactor (HFIR). The first is a passive experiment, referred to as the PRECISE experiment, that leverages the constant coolant pressure of HFIR to compress a metallic bellows and provide a well-characterized load to drive creep in a SiC/SiC dog bone specimen. The total creep strain would be quantified post-irradiation by measuring dimensional changes of the specimen length as well as local dimensional changes within the gauge region. Non-stressed specimens would also be irradiated under the same conditions to provide an indication of dimensional changes due to radiation-induced swelling in the absence of creep. A second, more complex experiment, referred to as the INSITE experiment, is being designed in parallel that would use pneumatics to pressurize a metal bellows and linear variable differential transformers (LVDTs) to measure the specimen displacement in situ during irradiation. Such an experiment would provide significantly more data regarding the evolution of the creep compliance as a function of dose and applied stress within a single experiment but would require significantly more development time and cost to execute. The primary concern with the INSITE experiment is the accuracy, reliability, and expected lifetime of the LVDTs during irradiation at elevated temperatures. Efforts are being made to adjust the experiment design and operating procedure to limit LVDT temperatures and mitigate or otherwise compensate for uncertainties due to factors such as temperature fluctuations, creep in the surrounding structural materials, and drift of the LVDTs. This work describes the experiment designs, thermal and structural analysis that were performed to ensure that the desired temperature and stress conditions can be achieved, some initial sensitivity analyses to predict the evolution of the radiation-induced specimen displacements, and potential sources of uncertainty in the measurements. Out-of-pile testing is being performed in parallel to confirm that the test trains achieve the expected stress states in the specimens and do not result in prohibitive stress concentrators (e.g., in the grip regions) that might risk pre-mature failure. The PRECISE experiments are proceeding toward fabrication and assembly with HFIR insertion planned during fiscal year 2026. The INSITE experiment is progressing toward out-of-pile demonstrations, which will provide more conclusive evidence regarding the feasibility of executing these tests in HFIR or whether alternative displacement monitoring techniques may need to be considered.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Large-Scale Reactive Extrusion Deposition of Sparse Infill Structures with Solid Perimeters

Large-scale additive manufacturing of reactive polymer systems offers significant improvements over thermoplastics through improved mechanical properties, faster deposition rates, and deposition at ambient temperatures. At ambient temperatures, the resin exists as a viscoelastic liquid which require additional additives for improved rigidity and bead stability. These filler-reinforced resins, or yield stress fluids, are soft solid-like materials able to withstand compressive forces from successive layer deposition until curing leads to bead solidification. When bead deposition is unsupported by previous layers, as is the case when bridging a gap, the creep due to gravitational loading can lead to bead instabilities which result in excessive sagging or bead breakage. These bead instabilities are material dependent and susceptible to changes in filler composition and temperature rises due to exothermic reactions. This work implements a design solution for bridging sparse infill patterns in additively manufactured parts which are essential in the reduction of weight. A series of span tests over a range of distances, as multiples of nozzle diameter, were conducted to determine the critical distance where a bead would break. Additional layer depositions determined the number of layers needed to recover from sagging effects. This recovery was essential in the transition of sparse infill to solid infill printing, where solid infill is milled for a smooth surface finish. Without the capability of sparse-solid transition, additively manufactured parts would require further surface treatments such as spray coating, adding to cost and increasing production time. A standard domed-mold geometry is presented to show the success of this printing process.

Hershey, Christopher↗

Advanced virtual energy simulation training and research: IGCC with CO2 capture power plant

In this presentation, we highlight the deployment of a real-time dynamic simulator of an integrated gasification combined cycle (IGCC) power plant with CO{sub 2} capture at the Department of Energy's (DOE) National Energy Technology Laboratory's (NETL) Advanced Virtual Energy Simulation Training and Research (AVESTARTM) Center. The Center was established as part of the DOE's accelerating initiative to advance new clean coal technology for power generation. IGCC systems are an attractive technology option, generating low-cost electricity by converting coal and/or other fuels into a clean synthesis gas mixture in a process that is efficient and environmentally superior to conventional power plants. The IGCC dynamic simulator builds on, and reaches beyond, conventional power plant simulators to merge, for the first time, a 'gasification with CO{sub 2} capture' process simulator with a 'combined-cycle' power simulator. Fueled with coal, petroleum coke, and/or biomass, the gasification island of the simulated IGCC plant consists of two oxygen-blown, downward-fired, entrained-flow, slagging gasifiers with radiant syngas coolers and two-stage sour shift reactors, followed by a dual-stage acid gas removal process for CO{sub 2} capture. The combined cycle island consists of two F-class gas turbines, steam turbine, and a heat recovery steam generator with three-pressure levels. The dynamic simulator can be used for normal base-load operation, as well as plant start-up and shut down. The real-time dynamic simulator also responds satisfactorily to process disturbances, feedstock blending and switchovers, fluctuations in ambient conditions, and power demand load shedding. In addition, the full-scope simulator handles a wide range of abnormal situations, including equipment malfunctions and failures, together with changes initiated through actions from plant field operators. By providing a comprehensive IGCC operator training system, the AVESTAR Center is poised to develop a workforce well-prepared to operate and control commercial-scale gasification-based power plants capable of 90% pre-combustion CO{sub 2} capture and compression, as well as low sulfur, mercury, and NOx emissions. With additional support from the NETL-Regional University Alliance (NETL-RUA), the Center will educate and train engineering students and researchers by providing hands-on 'learning by operating' experience The AVESTAR Center also offers unique collaborative R&D opportunities in high-fidelity dynamic modeling, advanced process control, real-time optimization, and virtual plant simulation. Objectives and goals are aimed at safe and effective management of power generation systems for optimal efficiency, while protecting the environment. To add another dimension of realism to the AVESTAR experience, NETL will introduce an immersive training system with innovative three-dimensional virtual reality technology. Wearing a stereoscopic headset or eyewear, trainees will enter an interactive virtual environment that will allow them to move freely throughout the simulated 3-D facility to study and learn various aspects of IGCC plant operation, control, and safety. Such combined operator and immersive training systems go beyond traditional simulation and include more realistic scenarios, improved communication, and collaboration among co-workers.

01 COAL, LIGNITE, AND PEAT↗

Geographic Visualization of Power-Grid Dynamics

The visualization enables the simulation analyst to see changes in the frequency through time and space. With this technology, the analyst has a bird's eye view of the frequency at loads and generators as the simulated power system responds to the loss of a generator, spikes in load, and other contingencies. The significance of a contingency to the operation of an electrical power system depends critically on how the resulting tansients evolve in time and space. Consequently, these dynamic events can only be understood when seen in their proper geographic context. this understanding is indispensable to engineers working on the next generation of distributed sensing and control systems for the smart grid. By making possible a natural and intuitive presentation of dynamic behavior, our new visualization technology is a situational-awareness tool for power-system engineers.

Sukumar, Sreenivas R.↗

Full-duplex ultrasonic through-wall communication and power delivery system with frequency tracking

A method and apparatus provide simultaneous bi-directional communications through a barrier using a pair of piezoelectric transducers. Outside-to-inside transmission of differentially encoded binary data is only sampled at the inside when a known repeated bit in a Barker sequence is transmitted in the other direction. Differentially encoded data is translated based on the absolute value of differences between each signal envelope sample and the previous signal envelope sample. Inside-to-outside data is transmitted by varying an electrical load on the inside transducer to vary the proportion of a continuous wave signal it reflects. The reflected portion of the continuous wave changes the electrical impedance of the outside transducer and this change is measured and interpreted as binary data. Two frequency selection algorithms select minimally sufficient and then optimal frequencies for power and data transmission by a frequency stepping process.

Lawry, Tristan J.↗

Absorbing the Sun: Operational Practices and Balancing Reserves in Florida's Municipal Utilities

The Florida Reliability Coordinating Council (FRCC) power system is comprised of multiple balancing authorities ranging in size from Gainesville Regional Utilities (GRU) with a 2019 summer net firm demand of 429 MW to Florida Power & Light with a 2019 summer net firm demand of 22,510 MW; and including cooperative, municipal, and investor-owned utilities. As all of these balancing authorities are and have plants to continue installing significant quantities of utility-scale solar photovoltaics, one relevant question is how much operating reserves they will need to hold as solar penetrations increase. While there are estimates of how regulating and flexibility reserve requirements change with solar penetration, the literature almost exclusively focuses on large balancing authorities with sub-hourly dispatch. In this work we analyze how reserve needs change not only with solar photovoltaic penetration, but also balancing authority size and operational practices. We find that, measured as a fraction of load, smaller balancing authorities with less frequent load and solar forecasts and less frequent dispatch need more reserves. Such utilities' reserve needs also increase more with increasing solar deployment as compared to larger or more frequently dispatched balancing authorities. These impacts are most acute for GRU. We find that moving from day-ahead to hour-ahead load and solar forecasting and system dispatch could enable GRU to incorporate 32% solar generation with median reserves at 20% instead of 60% of load; and that median reserve needs could drop further to about 10% of load if Florida's municipal utilities formed a reserve sharing group and moved to sub-hourly dispatch.

balancing authority↗

Cyber-Resilient Distributed Autonomous Energy Grid

The aim of Cyber-Resilient Distributed Autonomous Grid research initiative is to advance fundamental science and engineering approaches for cyber-resilient design, control, and operation of a distributed, highly interconnected, and autonomous energy grid of the future. From increasing penetration of DERs, smart homes and building with highly controllable loads at the distribution layer, to the interconnection of bulk renewables at the transmission layer the fundamental nature of the energy grid is changing, and these changes are enabled by rapid increase in dependence on the communication infrastructure and independent third parties for control and operation of the grid. NREL's Integrated Energy Pathways critical objective correctly identifies that there are fundamental cyber-resilience challenges inherent in the grid's evolution, and this effort is establishing strong and novel integrated cyber-resilience framework and approaches to address these new and fundamental challenges.

controls↗

Properties of Active Water Cooling Atmospheric Plasma Spraying Tungsten Coating

Tungsten coating was deposited onto an actively water-cooled oxygen-free copper substrate by atmospheric plasma spraying technique. The properties of the microstructure, porosity, microhardness and oxidation of the active water cooling atmospheric plasma spraying tungsten coating were characterized and measured. High heat load and thermal response tests using an electron beam facility have been carried out on the tungsten coated mock-ups under the water cooling condition. The heat flux is changed from 3 to 10 MW/m{sup 2} under the condition that the water flow rate is 2.5, 2.0 and 1.5 m{sup 3}/h, respectively. It is demonstrated that the mock-ups successfully withstood a heat flux of 15.5 MW/m{sup 2} at steady state.

36 MATERIALS SCIENCE↗

Guest Editorial Introduction to the Special Issue on 'Advanced Signal Processing Techniques and Telecommunications Network Infrastructures for Smart Grid Analysis, Monitoring, and Management'

Electrical power systems are undergoing a radical change in structure, components, and operational paradigms, and are progressively approaching the new concept of smart grids (SGs). Future power distribution systems will be characterized by the simultaneous presence of various distributed resources, such as renewable energy systems (i.e., photovoltaic power plant and wind farms), storage systems, and controllable/non-controllable loads. Control and optimization architectures will enable network-wide coordination of these grid components in order to improve system efficiency and reliability and to limit greenhouse gas emissions. In this context, the energy flows will be bidirectional from large power plants to end users and vice versa; producers and consumers will continuously interact at different voltage levels to determine in advance the requests of loads and to adapt the production and demand for electricity flexibly and efficiently also taking into account the presence of storage systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗