In situ growth of copper nanocrystals from carbonaceous microspheres with electrochemical glucose sensing properties

Graphical abstract: In situ growth of copper nanoparticles from hydrothermal copper-containing carbonaceous microspheres was induced by annealing or electron beam irradiation. Obtained micro-nano carbon/copper composite microspheres show electrochemical glucose sensing properties. - Highlights: • We synthesized carbonaceous microspheres containing non-nanoparicle copper species through a hydrothermal route. • By annealing or electron beam irradiation, copper nanoparticles would form from the carbonaceous microspheres in situ. • By controlling the annealing temperature, particle size of copper could be controlled in the range of 50–500 nm. • The annealed carbon/copper hierarchical composite microspheres were used to fabricate an electrochemical glucose sensor. - Abstract: In situ growth of copper nanocrystals from carbon/copper microspheres was observed in a well-controlled annealing or an electron beam irradiation process. Carbonaceous microspheres containing copper species with a smooth appearance were yielded by a hydrothermal synthesis using copper nitrate and ascorbic acid as reactants. When annealing the carbonaceous microspheres under inert atmosphere, copper nanoparticles were formed on carbon microspheres and the copper particle sizes can be increased to a range of 50–500 nm by altering the heating temperature. Similarly, in situ formation of copper nanocrystals from these carbonaceous microspheres was observed on the hydrothermal product carbonaceous microspheres with electron beam irradiation in a vacuum transmission electron microscopy chamber. The carbon/copper composite microspheres obtained through annealing were used to modify a glassy carbon electrode and tested as an electrochemical glucose sensor.

36 MATERIALS SCIENCE↗

Crystallization-driven assembly of conjugated-polymer-based nanostructures

The goal of this project has been to improve our ability to simultaneously control the organization, and therefore the opto-electronic properties, of conjugated-polymer based materials across three different length-scales: 1) the molecular scale, in the sense of controlling growth and functionalization of highly crystalline semiconducting organic materials capable of efficient charge transport, 2) the nanoscale, in terms of positioning n- and p-type materials with domain sizes comparable to exciton diffusion lengths (~ 10 nm) to facilitate charge separation, and 3) the colloidal scale, such that well-defined crystalline nanoscale building blocks can be hierarchically organized into device layers. As described in more detail below, the project was successful in generating powerful new approaches to, and improved fundamental understanding of, processing and self-assembly of organic and hybrid semiconducting materials across all three length-scales. Although the goals of the project were formulated with primarily photovoltaic architectures in mind, the outcomes of the project have significant implications for a variety of conjugated-polymer-based devices including field-effect-transistors for sensors and logic devices, as well as potentially thermoelectrics and battery electrode materials. The project has resulted in 10 peer-reviewed publications to date [1-10], with several additional manuscripts currently in preparation.

36 MATERIALS SCIENCE↗

Chromium Vapor Sensor for Monitoring Solid Oxide Fuel Cell Systems

One of the major degradation mechanisms in solid oxide fuel cells (SOFCs) is cathode poisoning by chromium due to vaporization from the metallic interconnect or balance-of-plant materials. Information on the chromium content in an operating fuel cell would be useful to anticipate degradation and take appropriate precautions. In this project, sensors for measuring the concentration of chromium-containing gases in a SOFC system were developed. The sensors are electrochemical sensors based on solid electrolytes with an auxiliary electrode to provide the sensitivity to chromium. Two different solid electrolyte materials were used: An oxygen ion conducting electrolyte, yttria stabilized zirconia, and a sodium ion conducting electrolyte, beta” alumina. The sensor based on beta” alumina generated a larger response to the presence of chromium. The concept of using a thin-film conducting oxide to measure the cumulative amount of chromium was also evaluated. The sensor was based on amanganese-copper oxide thin film and underwent an increase in resistance upon exposure to a chromium-containing gas.

20 FOSSIL-FUELED POWER PLANTS↗

Design and fabrication of a CMOS-compatible MHP gas sensor

A novel micro-hotplate (MHP) gas sensor is designed and fabricated with a standard CMOS technology followed by post-CMOS processes. The tungsten plugging between the first and the second metal layer in the CMOS processes is designed as zigzag resistor heaters embedded in the membrane. In the post-CMOS processes, the membrane is released by front-side bulk silicon etching, and excellent adiabatic performance of the sensor is obtained. Pt/Ti electrode films are prepared on the MHP before the coating of the SnO{sub 2} film, which are promising to present better contact stability compared with Al electrodes. Measurements show that at room temperature in atmosphere, the device has a low power consumption of ∼19 mW and a rapid thermal response of 8 ms for heating up to 300 °C. The tungsten heater exhibits good high temperature stability with a slight fluctuation (<0.3%) in the resistance at an operation temperature of 300 °C under constant heating mode for 336 h, and a satisfactory temperature coefficient of resistance of about 1.9‰/°C.

36 MATERIALS SCIENCE↗

Material Damage System and Method for Determining Same

A system and method for determining a change in a thickness and temperature of a surface of a material are disclosed herein. The system and the method are usable in a thermal protection system of a space vehicle, such as an aeroshell of a space vehicle. The system and method may incorporate micro electric sensors arranged in a ladder network and capacitor strip sensors. Corrosion or ablation causes a change in an electrical property of the sensors. An amount of or rate of the corrosion or the ablation and a temperature of the material is determined based on the change of the electrical property of the sensors.

Okojie, Robert↗

Material Damage System and Method for Determining Same

A system and method for determining a change in a thickness and temperature of a surface of a material are disclosed herein. The system and the method are usable in a thermal protection system of a space vehicle, such as an aeroshell of a space vehicle. The system and method may incorporate micro electric sensors arranged in a ladder network and capacitor strip sensors. Corrosion or ablation causes a change in an electrical property of the sensors. An amount of or rate of the corrosion or the ablation and a temperature of the material is determined based on the change of the electrical property of the sensors.

Okojie, Robert S.↗

Orientation Sensitive SEIRA Sensors Based on Single-Walled Carbon Nanotube Near Fields

Molecular vibrations that bear information about intrinsic properties of chemical compounds are challenging to detect at submonolayer densities. Surface-enhanced infrared absorption (SEIRA) spectroscopy has been proven to be a viable approach to enhance and detect weak vibration signals. Here, in this study, we report a SEIRA sensor based on mid-infrared surface plasmon resonances supported by single-walled carbon nanotubes (SWCNTs). Due to the 1D nature of SWCNTs, their plasmon modes are highly polarized with the electromagnetic fields spatially confined to nanometer scales. Leveraging these characteristics of SWCNTs, we observe a polarization selective coupling between their surface plasmons and vibrational modes of chemical bonds introduced onto their surfaces. A maximum modulation of similar to 15% to the plasmon resonance peak is obtained for a submonolayer chemical group coverage. These findings suggest that SWCNTs may potentially serve as a highly sensitive SEIRA platform for revealing intricate information about molecular compositions and bond orientations.

36 MATERIALS SCIENCE↗

Ammonia gas sensors: A comprehensive review

We report that in recent years, sensitive, selective and accurate sensing techniques for ammonia gas detection have been highly demanded since ammonia is both a commonly utilized gas in various industrial sectors and a highly toxic and corrosive agent that can threat human health and environment. This review article discusses the widely used gas sensing techniques in ammonia detection. The fundamental working principles of the ammonia detection techniques relying on electronics, electrochemistry, tunable diode laser spectroscopy, surface acoustic wave, and field effect transistors are briefly described first, in conjunction with various sensing materials. Furthermore, recent progress in the development of advanced ammonia gas sensors was comprehensively reviewed and summarized. Finally, the outlook for future development of high-performance ammonia sensors was presented.

47 OTHER INSTRUMENTATION↗

Novel Millimeter Wave Sensor Concepts for Energy, Environment, and National Security

Millimeter waves (30 – 300 GHz) are ideally suited for sensing and diagnosing materials, devices, and processes that are broadly important to energy, environment, and national security missions. The wavelengths are long enough to penetrate dust, smoke, and industrial environment yet short enough to enable focusing and manipulating of the signals for useful applications. We have developed a novel thermal return reflection (TRR) technique that uses emission as a probe to interrogate and diagnose materials and systems and determine emissivity and temperature simultaneously. Scientific basis of TRR, 2-D and potentially 3-D measurements, and selected results on application of TRR will be presented. We will also present new sensor concepts based on emit-probe and pump-probe modes to further broaden its applications. In its 3-D manifestation of this technique, one can track three different parameters or view/measure at three different directions (x, y, and z). On application to materials and processes, it shows promise for measuring temperature (T) - position (x) - time (t) simultaneously in real time leading to T-x-t diagrams that can be exploited for spatial resolution of emissivity or stability over a function of time. Selected examples of applications in fusion plasma diagnostics, nuclear waste disposal, and non-proliferation will be presented.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Angle-resolved diffraction grating biosensor based on porous silicon

In this study, an optical biosensor based on a porous silicon composite structure was fabricated using a simple method. This structure consists of a thin, porous silicon surface diffraction grating and a one-dimensional porous silicon photonic crystal. An angle-resolved diffraction efficiency spectrum was obtained by measuring the diffraction efficiency at a range of incident angles. The angle-resolved diffraction efficiency of the 2nd and 3rd orders was studied experimentally and theoretically. The device was sensitive to the change of refractive index in the presence of a biomolecule indicated by the shift of the diffraction efficiency spectrum. The sensitivity of this sensor was investigated through use of an 8 base pair antifreeze protein DNA hybridization. The shifts of the angle-resolved diffraction efficiency spectrum showed a relationship with the change of the refractive index, and the detection limit of the biosensor reached 41.7 nM. This optical device is highly sensitive, inexpensive, and simple to fabricate. Using shifts in diffraction efficiency spectrum to detect biological molecules has not yet been explored, so this study establishes a foundation for future work.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Material properties limiting the performance of CZT gamma-ray detectors

CdZnTe (CZT) nuclear radiation detectors are advanced sensors that utilize innovative technologies developed for wide band-gap semiconductor industry and microelectronics. They open opportunities for new types of room-temperature operating, field deployable instruments that provide accurate identification of potential radiological threats and timely awareness for both the civilian and military communities. Room-temperature radiation detectors are an emerging technology that relies on the use of high-quality CZT crystals whose availability is currently limited by material non-uniformities and the presence of extended defects. To address these issues, which are most critical to CZT sensor developments, we developed X-ray mapping and IR transmission microscopy systems to characterize both CZT crystals and devices. Since a customized system is required for such X-ray measurements, we use synchrotron radiation beams available at BNL's National Synchrotron Light Source. A highly-collimated and high-intensity X-ray beam supports measurements of areas as small as 10 x 10 {micro}m{sup 2}, and allowed us to see fluctuations in collected charge over the entire area of the detector in a reasonable time. The IR microscopy system allows for 3D visualization of Te inclusions and other extended defects. In this paper, we describe the experimental techniques used in our measurements and typical results obtained from CZT samples produced by different suppliers.

43 PARTICLE ACCELERATORS↗

Quantitative Principles for Precise Engineering of Sensitivity in Graphene Electrochemical Sensors

Abstract A major difficulty in implementing carbon‐based electrode arrays with high device‐packing density is to ensure homogeneous and high sensitivities across the array. Overcoming this obstacle requires quantitative microscopic models that can accurately predict electrode sensitivity from its material structure. Such models are currently lacking. Here, it is shown that the sensitivity of graphene electrodes to dopamine and serotonin neurochemicals in fast‐scan cyclic voltammetry measurements is strongly linked to point defects, whereas it is unaffected by line defects. Using the physics of point defects in graphene, a microscopic model is introduced that explains how point defects determine sensitivity. The predictions of this model match the empirical observation that sensitivity linearly increases with the density of point defects. This model is used to guide the nanoengineering of graphene structures for optimum sensitivity. This approach achieves reproducible fabrication of miniaturized sensors with extraordinarily higher sensitivity than conventional materials. These results lay the foundation for new integrated electrochemical sensor arrays based on nanoengineered graphene.

Wu, Ting↗

Embedding thermocouples in SS316 with laser powder bed fusion

Recent advances in manufacturing technologies have enabled the fabrication of complex geometries for a wide range of applications, including the energy, aerospace, and civil sectors. The ability to integrate sensors at critical locations within these complex components during the manufacturing process could benefit process monitoring and control by reducing reliance on models to relate surface measurements to internal phenomena. This study investigated embedding thermocouples in a SS316 matrix using laser powder bed fusion. Under optimal processing conditions, embedded thermocouples were characterized post-building, finding good bonding to the matrix with no melt pool penetration to the sensing elements. Futher, the embedded thermocouple performed similarly to an identical non-embedded thermocouple during thermal testing to 500 °C with only a slight difference in response time, which was attributed to the differences in mass and the associated thermal time constants.

image analysis↗

Inspection of the objects on the sea floor by using 14 MeV tagged neutrons

Variety of objects found on the sea floor needs to be inspected for the presence of materials which represent the threat to the environment and to the safety of humans. We have demonstrated that the sealed tube 14 MeV neutron generator with the detection of associated alpha particles can be used underwater when mounted inside ROV equipped with the hydraulic legs and variety of sensors for the inspection of such objects for the presence of threat materials. Such a system is performing the measurement by using the NaI gamma detector and an API-120 neutron generator which could be rotated in order to maximize the inspected target volume. The neutron beam intensity during the 10-30 min. measurements is usually 1 x 10{sup 7} n/s in 4{pi}. In this report the experimental results for some of commonly found objects containing TNT explosive or its simulant are presented. The measured gamma spectra are dominant by C, O and Fe peaks enabling the determination of the presence of explosives inside the ammunition shell. Parameters influencing the C/O ratio are discussed in some details. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interfacial Lattice-Strain-Driven Generation of Oxygen Vacancies in an Aerobic-Annealed TiO 2 (B) Electrode

Oxygen vacancies play crucial roles in defining physical and chemical properties of materials to enhance the performances in electronics, solar cells, catalysis, sensors, and energy conversion and storage. Conventional approaches to incorporate oxygen defects mainly rely on reducing the oxygen partial pressure for the removal of product to change the equilibrium position. However, directly affecting reactants to shift the reaction toward generating oxygen vacancies is lacking and to fill this blank in synthetic methodology is very challenging. In this work, a strategy is demonstrated to create oxygen vacancies through making the reaction energetically more favorable via applying interfacial strain on reactants by coating, using TiO 2 (B) as a model system. Geometrical phase analysis and density functional theory simulations verify that the formation energy of oxygen vacancies is largely decreased under external strain. Benefiting from these, the obtained oxygen-deficient TiO 2 (B) exhibits impressively high level of capacitive charge storage, e.g., ≈53% at 0.5 mV s –1 , far surpassing the ≈31% of the unmodified counterpart. Meanwhile, the modified electrode shows significantly enhanced rate capability delivering a capacity of 112 mAh g –1 at 20 C (≈6.7 A g –1 ), ≈30% higher than air-annealed TiO 2 and comparable to vacuum-calcined TiO 2 . This work heralds a new paradigm of mechanical manipulation of materials through interfacial control for rational defect engineering.

36 MATERIALS SCIENCE↗

Robust Heat-Flux Sensors for Coal-Fired Boiler Extreme Environments

In this project, robust heat-flux measurement systems were developed. The heat-flux sensors utilize thermoelectric effects to directly transduce the heat-flux inputs to analog electrical voltage signals. They were constructed from dedicated materials that can withstand temperatures of at least 1000°C and maintain adequate performance at these conditions for prolonged periods of time. The proposed approaches took into account numerous considerations, including system cost, sensor head resilience, sensor footprint, data accuracy, response time, and maintenance requirements. Through modern thermoelectric materials design, methodical materials selection and rigorous testing in materials characterization labs and medium-scale fire research facilities, we have demonstrated functioning laboratory prototypes, upon which one could base industrial heat-flux sensing platforms capable of operating in the challenging high-temperature, corrosive environments of the boilers of coal-fired power plants. A distributed sensor array for heat-flux measurements throughout the furnace water-wall, the superheater area and the economizer coils can provide critical data for the power plant control systems to increase efficiency, improve safety and reduce down times. For example, the combined heat-flux sensor/control systems can contribute to the optimization of burner and boiler operations under flexible loads, the optimization of heat-exchange conditions and overall reduction of heat rate and emissions, the prediction of imminent overheating conditions, and the optimization of the soot-blowing protocols.

20 FOSSIL-FUELED POWER PLANTS↗

Development of a small radiation flux monitor

This paper describes the development of a miniaturized radiation flux monitor by means of Cherenkov light. The idea is to use the intensity of Cherenkov light as a measurement for the radiation flux. An initial test is performed with an extrinsic dielectric object which is coupled with an optical fibre. These test show that the Cherenkov radiation in the fibre itself was too high compared with the captured extrinsic light. Further test to use intrinsic Cherenkov fibre optic sensors are planned in the near future and the envisaged measurement set up is explained. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetoresistive Flux Focusing Eddy Current Flaw Detection

A giant magnetoresistive flux focusing eddy current device effectively detects deep flaws in thick multilayer conductive materials. The probe uses an excitation coil to induce eddy currents in conducting material perpendicularly oriented to the coil s longitudinal axis. A giant magnetoresistive (GMR) sensor, surrounded by the excitation coil, is used to detect generated fields. Between the excitation coil and GMR sensor is a highly permeable flux focusing lens which magnetically separates the GMR sensor and excitation coil and produces high flux density at the outer edge of the GMR sensor. The use of feedback inside the flux focusing lens enables complete cancellation of the leakage fields at the GMR sensor location and biasing of the GMR sensor to a location of high magnetic field sensitivity. In an alternate embodiment, a permanent magnet is positioned adjacent to the GMR sensor to accomplish the biasing. Experimental results have demonstrated identification of flaws up to 1 cm deep in aluminum alloy structures. To detect deep flaws about circular fasteners or inhomogeneities in thick multi-layer conductive materials, the device is mounted in a hand-held rotating probe assembly that is connected to a computer for system control, data acquisition, processing and storage.

Russell A Wincheski↗