Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

MEMS-tunable dielectric metasurface lens

Varifocal lenses, conventionally implemented by changing the axial distance between multiple optical elements, have a wide range of applications in imaging and optical beam scanning. The use of conventional bulky refractive elements makes these varifocal lenses large, slow, and limits their tunability. Metasurfaces, a new category of lithographically defined diffractive devices, enable thin and lightweight optical elements with precisely engineered phase profiles. Here we demonstrate tunable metasurface doublets, based on microelectromechanical systems (MEMS), with more than 60 diopters (about 4%) change in the optical power upon a 1-μm movement of one metasurface, and a scanning frequency that can potentially reach a few kHz. They can also be integrated with a third metasurface to make compact microscopes (~1 mm thick) with a large corrected field of view (~500 μm or 40 degrees) and fast axial scanning for 3D imaging. This paves the way towards MEMS-integrated metasurfaces as a platform for tunable and reconfigurable optics.

42 ENGINEERING↗

Multiple small angle neutron scattering: A new two-dimensional ultrasmall angle neutron scattering technique

We report on the demonstration experiment of the multiple small angle neutron scattering (MSANS) technique at a 5.6 m long neutron beam line, leading to a q resolution of 3x10{sup -4} A{sup -1}. The MSANS technique is based on two two-dimensional multihole apertures placed at the front end of the collimator and close to the sample, respectively. By choosing the proper MSANS geometry, individual diffraction patterns are superimposed leading to a large gain in intensity. Using MSANS as an option for standard small angle neutron scattering beam lines, the q resolution could be increased to 10{sup -5} A{sup -1} without dramatically sacrificing intensity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On-Going Nuclear Physics and Technology Research Programmes in Europe

Innovative nuclear technology applications have emerged in recent years and triggered an unprecedented interest of different communities of scientists worldwide, concerned by the multidisciplinary scientific, technical and engineering aspects of such applications. ADS (Accelerator Driven Systems, for the transmutation of highly radiotoxic nuclear waste), EA (Energy Amplifiers, for the production of energy), Spallation Neutron Sources (for multiple applications such as in Bio-Sciences, Medicine, Material Science), Radioactive Ion Beams (of relevance for fundamental Nuclear Physics and Astrophysics, for applications in Medicine, amongst many others) are examples of applications that address a set of common multidisciplinary, leading edge and cross-cutting issues and research topics. Other applications being considered for High-Energy Physics purposes consist on facilities aiming at producing intense neutrino beams.The sustainability of nuclear energy as an economically competitive, environmentally friend and proliferation resistant technology to meet mankind's growing energy demand has imposed in recent years the consideration of new (Generation IV) or non-conventional types of nuclear reactors, operating with non-standard coolants, higher-energy neutron spectra, higher temperatures, amongst other issues. The safety and operational aspects of these nuclear energy systems share with the nuclear technology applications previously referred (ADS, EA, SNS, etc.) a set of common scientific and technical issues.In this paper, the scientific, technical and engineering topics and issues of relevance for the implementation and deployment of some of the systems previously described are briefly presented. A set of selected major on-going R and D programmes and experiments involving international collaborations of scientists and consortia of institutions are succinctly described.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Determination of gain in AlGaN cladding free nitride laser diodes

The optical gain spectra of InGaN-based multiple-quantum-well (MQW) laser diodes (LDs) grown by plasma-assisted molecular beam epitaxy are compared for different emission wavelengths. Two AlGaN cladding free LDs with similar epitaxial structures but with different In compositions in MQW were grown to study the dependence of material gain on lasing wavelength. As the emission wavelength increased from 432 to 458 nm, the differential modal gain decreased from 5.7 to 4.7 cm/kA, and the optical losses increased from 40 to 46 cm{sup −1} resulting in an increase in threshold current density. This dependence is attributed to lower optical mode confinement of LD emitting at longer wavelength. We found a strong decrease of confinement factor with increasing wavelength.

36 MATERIALS SCIENCE↗

Axial proton probing of magnetic and electric fields inside laser-driven coils

In a laser-driven coil, a laser is used to eject electrons from a plate, which then draws a current through a loop. Diagnosing the field strength, geometry, and conditions within these loops has been one of the primary difficulties in fielding this type of target. In this paper, the diagnostic technique of axial proton probing with a mesh fiducial of a laser-driven coil is demonstrated. Multiple coil types were driven by a 1 ns, 1.25 kJ long pulse beam and probed several times. Here, this technique provides significantly more information than transverse probing on electric- and magnetic-field strength in the region of interest and shows in our experiment complex, non-uniform current path structures and charge distribution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CONSTRAINT ON THE PARAMETERS OF THE INVERSE COMPTON SCATTERING MODEL FOR RADIO PULSARS

The inverse Compton scattering (ICS) model can explain various pulse profile shapes and the diversity of the pulse profile evolution based on the mechanism where the radio emission is generated through ICS between secondary relativistic particles and radio waves from polar gap avalanches. In this paper, we study the parameter space of the ICS model for 15 pulsars that share the common pulse profile evolution phenomenon, where the pulse profiles are narrower at higher observing frequencies. Two key parameters, the initial Lorentz factor and the energy loss factor of secondary particles, are constrained using the least-squares fitting method, where we fit the theoretical curve of the 'beam-frequency mapping' of the ICS model to the observed pulse widths at multiple frequencies. The uncertainty of the inclination and viewing angles are taken into account in the fitting process. It is found that the initial Lorentz factor is larger than 4000, and the energy loss factor is between 20 and 560. The Lorentz factor is consistent with the prediction of the inner vacuum gap model. Such high-energy loss factors suggest significant energy loss for secondary particles at altitudes of a few tens to hundreds of kilometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarization and phase control of electron injection and acceleration in the plasma by a self-steepening laser pulse

Abstract We describe an interplay between two injection mechanism of background electrons into an evolving plasma bubble behind an intense laser pulse: one due to the overall bubble expansion, and another due to its periodic undulation. The two mechanisms occur simultaneously when an intense laser pulse propagating inside a plasma forms a shock-like steepened front. Periodic undulations of the plasma bubble along the laser propagation path can either inhibit or conspire with electron injection due to bubble expansion. We show that carrier-envelope-phase (CEP) controlled plasma bubble undulation induced by the self-steepening laser pulse produces a unique electron injector—expanding phase-controlled undulating bubble (EPUB). The longitudinal structure of the electron bunch injected by the EPUB can be controlled by laser polarization and power, resulting in high-charge (multiple nano-Coulombs) high-current (tens of kilo-amperes) electron beams with ultra-short (femtosecond-scale) temporal structure. Generation of high-energy betatron radiation with polarization- and CEP-controlled energy spectrum and angular distribution is analyzed as a promising application of EPUB-produced beams.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of sulfur SAD to small crystals with a large asymmetric unit and anomalous substructure

The application of sulfur single-wavelength anomalous dispersion (S-SAD) to determine the crystal structures of macromolecules can be challenging if the asymmetric unit is large, the crystals are small, the size of the anomalously scattering sulfur structure is large and the resolution at which the anomalous signals can be accurately measured is modest. Here, as a study of such a case, approaches to the SAD phasing of orthorhombic Ric-8A crystals are described. The structure of Ric-8A was published with only a brief description of the phasing process [Zeng et al. (2019), Structure , 27 , 1137–1141]. Here, alternative approaches to determining the 40-atom sulfur substructure of the 103 kDa Ric-8A dimer that composes the asymmetric unit are explored. At the data-collection wavelength of 1.77 Å measured at the Frontier micro-focusing Macromolecular Crystallography (FMX) beamline at National Synchrotron Light Source II, the sulfur anomalous signal strength, |Δ ano |/σΔ ano ( d ′′/sig), approaches 1.4 at 3.4 Å resolution. The highly redundant, 11 000 000-reflection data set measured from 18 crystals was segmented into isomorphous clusters using BLEND in the CCP 4 program suite. Data sets within clusters or sets of clusters were scaled and merged using AIMLESS from CCP 4 or, alternatively, the phenix.scale_and_merge tool from the Phenix suite. The latter proved to be the more effective in extracting anomalous signals. The HySS tool in Phenix , SHELXC / D and PRASA as implemented in the CRANK 2 program suite were each employed to determine the sulfur substructure. All of these approaches were effective, although HySS , as a component of the phenix.autosol tool, required data from all crystals to find the positions of the sulfur atoms. Critical contributors in this case study to successful phase determination by SAD included (i) the high-flux FMX beamline, featuring helical-mode data collection and a helium-filled beam path, (ii) as recognized by many authors, a very highly redundant, multiple-crystal data set and (iii) the inclusion within that data set of data from crystals that were scanned over large ω ranges, yielding highly isomorphous and highly redundant intensity measurements.

59 BASIC BIOLOGICAL SCIENCES↗

Dose calculation software for helical tomotherapy, utilizing patient CT data to calculate an independent three-dimensional dose cube

Purpose: Treatment plans for the TomoTherapy unit are produced with a planning system that is integral to the unit. The authors have produced an independent dose calculation system, to enable plans to be recalculated in three dimensions, using the patient's CT data. Methods: Software has been written using MATLAB. The DICOM-RT plan object is used to determine the treatment parameters used, including the treatment sinogram. Each projection of the sinogram is segmented and used to calculate dose at multiple calculation points in a three-dimensional grid using tables of measured beam data. A fast ray-trace algorithm is used to determine effective depth for each projection angle at each calculation point. Calculations were performed on a standard desktop personal computer, with a 2.6 GHz Pentium, running Windows XP. Results: The time to perform a calculation, for 3375 points averaged 1 min 23 s for prostate plans and 3 min 40 s for head and neck plans. The mean dose within the 50% isodose was calculated and compared with the predictions of the TomoTherapy planning system. When the modified CT (which includes the TomoTherapy couch) was used, the mean difference for ten prostate patients, was -0.4% (range -0.9% to +0.3%). With the original CT (which included the CT couch), the mean difference was -1.0% (range -1.7% to 0.0%). The number of points agreeing with a gamma 3%/3 mm averaged 99.2% with the modified CT, 96.3% with the original CT. For ten head and neck patients, for the modified and original CT, respectively, the mean difference was +1.1% (range -0.4% to +3.1%) and 1.1% (range -0.4% to +3.0%) with 94.4% and 95.4% passing a gamma 4%/4 mm. The ability of the program to detect a variety of simulated errors has been tested. Conclusions: By using the patient's CT data, the independent dose calculation performs checks that are not performed by a measurement in a cylindrical phantom. This enables it to be used either as an additional check or to replace phantom measurements for some patients. The software has potential to be used in any application where one wishes to model changes to patient conditions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-47: Development of a High-Precision, Image-Guided Radiotherapy, Multi- Purpose Radiation Isocenter Quality-Assurance Calibration and Checking System

Purpose: To develop a system that can define the radiation isocenter and correlate this information with couch coordinates, laser alignment, optical distance indicator (ODI) settings, optical tracking system (OTS) calibrations, and mechanical isocenter walkout. Methods: Our team developed a multi-adapter, multi-purpose quality assurance (QA) and calibration device that uses an electronic portal imaging device (EPID) and in-house image-processing software to define the radiation isocenter, thereby allowing linear accelerator (Linac) components to be verified and calibrated. Motivated by the concept that each Linac component related to patient setup for image-guided radiotherapy based on cone-beam CT should be calibrated with respect to the radiation isocenter, we designed multiple concentric adapters of various materials and shapes to meet the needs of MV and KV radiation isocenter definition, laser alignment, and OTS calibration. The phantom's ability to accurately define the radiation isocenter was validated on 4 Elekta Linacs using a commercial ball bearing (BB) phantom as a reference. Radiation isocenter walkout and the accuracy of couch coordinates, ODI, and OTS were then quantified with the device. Results: The device was able to define the radiation isocenter within 0.3 mm. Radiation isocenter walkout was within ±1 mm at 4 cardinal angles. By switching adapters, we identified that the accuracy of the couch position digital readout, ODI, OTS, and mechanical isocenter walkout was within sub-mm. Conclusion: This multi-adapter, multi-purpose isocenter phantom can be used to accurately define the radiation isocenter and represents a potential paradigm shift in Linac QA. Moreover, multiple concentric adapters allowed for sub-mm accuracy for the other relevant components. This intuitive and user-friendly design is currently patent pending.

07 ISOTOPE AND RADIATION SOURCES↗

WE-AB-209-06: Dynamic Collimator Trajectory Algorithm for Use in VMAT Treatment Deliveries

Purpose: To develop advanced dynamic collimator positioning algorithms for optimal beam’s-eye-view (BEV) fitting of targets in VMAT procedures, including multiple metastases stereotactic radiosurgery procedures. Methods: A trajectory algorithm was developed, which can dynamically modify the angle of the collimator as a function of VMAT control point to provide optimized collimation of target volume(s). Central to this algorithm is a concept denoted “whitespace”, defined as area within the jaw-defined BEV field, outside of the PTV, and not shielded by the MLC when fit to the PTV. Calculating whitespace at all collimator angles and every control point, a two-dimensional topographical map depicting the tightness-of-fit of the MLC was generated. A variety of novel searching algorithms identified a number of candidate trajectories of continuous collimator motion. Ranking these candidate trajectories according to their accrued whitespace value produced an optimal solution for navigation of this map. Results: All trajectories were normalized to minimum possible (i.e. calculated without consideration of collimator motion constraints) accrued whitespace. On an acoustic neuroma case, a random walk algorithm generated a trajectory with 151% whitespace; random walk including a mandatory anchor point improved this to 148%; gradient search produced a trajectory with 137%; and bi-directional gradient search generated a trajectory with 130% whitespace. For comparison, a fixed collimator angle of 30° and 330° accumulated 272% and 228% of whitespace, respectively. The algorithm was tested on a clinical case with two metastases (single isocentre) and identified collimator angles that allow for simultaneous irradiation of the PTVs while minimizing normal tissue irradiation. Conclusion: Dynamic collimator trajectories have the potential to improve VMAT deliveries through increased efficiency and reduced normal tissue dose, especially in treatment of multiple cranial metastases, without significant safety concerns that hinder immediate clinical implementation.

60 APPLIED LIFE SCIENCES↗

Multi-alkalai photocathodes production for LEReC DC gun

Low Energy RHIC electron Cooling (LEReC) is a bunched electron cooler at RHIC. The LEReC’s electron source needs provide up to 85 mA average current electron beam. The Bi-alkali photocathodes are chosen as electron source due to its long lifetime and high QE at the visible wavelength. Because the DC gun needs to produce 24/7 beams over several months, two cathode production systems and three transfer systems carrying multiple cathodes are designed and one set commissioned. In this report, we will describe our photocathode production and transfer systems and discuss the cathode's performance from cathode growth system to the DC gun.

43 PARTICLE ACCELERATORS↗

Presentation for ISTC and ISWS [Slides]

Currently we are integrating multiple new technologies to create a compact, portable, high power, high reliability electron beam platform accelerator; We are concurrently developing applications for this compact accelerator.

43 PARTICLE ACCELERATORS↗

ANNIE in 10 Minutes

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton gadolinium-doped water Cherenkov detector situated 100-m downstream in Fermilab's Booster Neutrino Beam. ANNIE's main physics goal is to measure the final state neutron multiplicity of neutrino-nucleus interactions as a function of momentum transfer. This measurement will improve our understanding of these complex interactions and help reduce the associated systematic uncertainties, thus benefiting the next generation of long-baseline neutrino experiments. ANNIE will achieve its physics goals with the use of a new type of photodetector, the Large Area Picosecond Photodetector (LAPPD). The experiment is the first physics experiment to deploy an array of LAPPDs. Significant progress has been made on the characterization and development of this system. In this talk, we will present the status of ANNIE experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Second year technical report on-board processing for future satellite communications systems

Advanced baseband and microwave switching techniques for large domestic communications satellites operating in the 30/20 GHz frequency bands are discussed. The nominal baseband processor throughput is one million packets per second (1.6 Gb/s) from one thousand T1 carrier rate customer premises terminals. A frequency reuse factor of sixteen is assumed by using 16 spot antenna beams with the same 100 MHz bandwidth per beam and a modulation with a one b/s per Hz bandwidth efficiency. Eight of the beams are fixed on major metropolitan areas and eight are scanning beams which periodically cover the remainder of the U.S. under dynamic control. User signals are regenerated (demodulated/remodulated) and message packages are reformatted on board. Frequency division multiple access and time division multiplex are employed on the uplinks and downlinks, respectively, for terminals within the coverage area and dwell interval of a scanning beam. Link establishment and packet routing protocols are defined. Also described is a detailed design of a separate 100 x 100 microwave switch capable of handling nonregenerated signals occupying the remaining 2.4 GHz bandwidth with 60 dB of isolation, at an estimated weight and power consumption of approximately 400 kg and 100 W, respectively.

Brandon, W. T.↗

Auroral electron acceleration and atmospheric interactions - /1/ Rocket-borne observations and /2/ scattering calculations

Electron energy and pitch angle spectra are obtained by an instrumented rocket payload launched across a pre-midnight auroral arc. The interaction of the incident electron beam with the atmosphere is described through transport theory including inelastic and multiple-elastic scattering of electrons by neutrals. A two-stream approximation to the electron transport equation is used to compute the hemispherically averaged upcoming electron transport that resulted from the measured downcoming intensity. The model of Evans (1974) is employed to infer a primary electron spectrum within the discrete arc.

Pulliam, D. M.↗

A three-dimensional incompressible flow simulation method and its application to the Space Shuttle main engine. II Turbulent flow

An implicit finite difference code cast in general curvilinear coordinates is further developed for three-dimensional incompressible turbulent flows. The code is based on the method of pseudocompressibility and utilizes the Beam and Warming implicit approximate factorization algorithm to achieve computational efficiency. A multiple-zone method is further extended to include composite-grids to overcome the excessive computer memory required for solving turbulent flows in complex three-dimensional geometries. A simple turbulence model is proposed for internal flows. The code is being used for the Space Shuttle Main Engine (SSME) internal flow analyses.

Chang, J. L. C.↗

A personal communications network using a Ka-band satellite

The feasibility of portable communications terminals that can provide 4.8-kbps voice communications to a hub station via a Ka-band geosynchronous satellite was investigated. Tradeoffs are examined so that the combined system of the hub and gateway earth stations, the satellite, and the personal terminals can provide a competitive service in terms of cost, availability, and quality. A baseline system is described using a spacecraft with approximately 140 spot beams that cover CONUS with 5-watt power amplifiers in each beam. Satellite access in both the forward and return directions uses Frequency Division Multiple Access/Code Division Multiple Access (FDMA/CDMA) with a chip rate of 2.5 Mchip/sec. An experiment is recommended using the Advanced Communications Technology Satellite (ACTS) to demonstrate some of the features of the portable terminal concept.

Palmer, L. C.↗