Search NASA⌕ Search

SEARCH · Search NASA

Results for “pool”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Assessment of Sodium Thermal Stratification Models Utilizing the TSTF Benchmark

As a result of certain transient scenarios, a thermally stratified layer of liquid sodium can develop in the bulk coolant volumes of a sodium-cooled fast reactor (SFR). In addition to the effects a stratification layer has on the temperature of the heat transport system, a stratification layer can also influence the transition to and establishment of natural circulation flow, which plays an important role in passive cooling and the inherent safety of a pool-type SFR. Therefore, the ability to accurately capture thermal stratification phenomena is important when demonstrating the safety basis of a pool-type SFR during transient sequences. The present work assesses various computational models with different fidelities in their ability to predict thermal stratification in the upper plenum of an SFR. Each computational model will be assessed using the data generated at the Thermal Stratification Test Facility (TSTF) located at the University of Wisconsin-Madison. Using measured flow rate and inlet temperature data, the measured temperature distributions of the tests are compared to the predictions of the lumped volume-based models in SAS4A/SASSYS-1, a 1D-based model in SAM, and a 3-D computational fluid dynamics (CFD) model using STAR-CCM+. The relative performance of the various computational methods is assessed with respect to key metrics such as bulk coolant temperature distribution and plenum exit temperature. A total of eight tests are analyzed, covering different combinations of flow rates (3 and 10 GPM) and upper internal structure (UIS) configurations (none, solid, porous, and open) The perfect mixing model of SAS4A/SASSYS-1 provides the highest accuracy when the flow rate is high and there is no UIS in the test vessel, as high flow rate injection promotes thermal mixing of the sodium in the test vessel. For most of the analyzed tests, the stratified volume model of SAS4A/SASSYS-1 is able to predict the delay in the outlet temperature drop and temperature distribution in the test vessel by a small number of layers to represent thermal stratification. However, the stratified volume model can only simulate a maximum of three temperature layers within a volume and when a layer approaches the elevation of the outlet, the predicted outlet temperature can demonstrate rapid, non-physical changes. The 1-D axial mixing model of SAM provides results that agree reasonably well with the measured data in the prediction of the temporal evolution of the outlet temperature with the exception of the case with a high flow rate and no UIS. The SAM 1-D model has a similar level of accuracy to CFD results when it comes to predicting the outlet temperature. CFD shows overall good agreement in predicting the temperature distribution in the test vessel and outlet temperature. As CFD can model the test vessel geometry in detail, it performs well in the cases of complex geometries such as tests that included a UIS and internal flow through the UIS resulting in active mixing of the coolant in the test vessel. Each of the models discussed in the present work has the potential to be useful during the various stages of reactor design, analysis, and licensing. The lumped-volume approach can be applied for fast turnaround safety calculations to obtain overall reactor behavior during transients. The 1-D models provide improved accuracy when stratification is expected for a relatively low increase in the computational cost. The CFD model can be utilized for confirmatory analysis of the 1-D model, when experimental measurements are not available.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Vacuum Drying Study of Simulated Failed Nuclear Fuel (FY23)

This report documents work performed under the Office of Spent Fuel and Waste Disposition’s (SFWD’s) Spent Fuel and Waste Science and Technology program for the US Department of Energy (DOE) Office of Nuclear Energy (NE). This work was performed to fulfill Level 4 milestone M4SF-23OR010203013. Over the 70 years of light-water reactor (LWR) operation, fuel rod failures have occurred during reactor operation. Based on the Unified Database that SFWD maintains, there are ~5,400 LWR fuel rods that developed leaks during reactor operation of the >19 million rods operated. The Unified Database indicates that ~4,200 of these rods remain in the spent fuel pool, and ~1,200 are in dry storage canisters. It is expected that all failed rods are “waterlogged” in the spent fuel pool, meaning the inside of the rods contain some volume of water. There are two related objectives of this work. The first is to develop a simple and inexpensive experiment to better understand removal of water from inside failed spent nuclear fuel (SNF) rods, and the second is to develop a model to predict drying of simulated failed fuel in the simple experiment. Once a model captures the phenomenon in the simple experiment, it can be extended to predict drying under more prototypical conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal Hydraulic Experimental Test Article - Fiscal Year 2023 (Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that is used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility simulates nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field may be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility was designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary coolant and secondary coolant system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. To date a test matrix has been completed utilizing the primary system of THETA. These tests, along with computational fluid dynamics and systems code models, determined the heat transfer across the core barrel and intermediate heat exchanger outlet was too great to effectively represent scaled thermal hydraulic phenomena of a liquid metal cooled reactor. Therefore, a significant effort was made to remove the primary system from the METL 28” test vessel #4 and clean the residual sodium from the primary system to facilitate upgrades. Thermal insulation was then incorporated in the core barrel and intermediate heat exchanger outlets. The primary system was then replaced, and a series of tests were performed to assess the performance of the thermal insulation. With primary system testing and upgrades complete, the secondary system could then be brought online. The tube side of the shell-and-tube intermediate heat exchanger was installed onto the primary system flange to begin installing the secondary system. The support structure for the secondary system was then erected on the METL mezzanine alongside the THETA primary system to facilitate installation of the secondary system components (sodium-to-air heat exchanger, flowmeter and pump). The piping and expansion tank were welded into the secondary system. Non-destructive examination of the secondary system welds was completed in order to satisfy ASME B31.3 pipe code for class M process fluids. The heating system and insulation were then added to prepare the system to be filled with sodium. The ancillary electrical equipment was installed which included the pump control box, blower VFD, pipe heater control system, etc. The secondary system will be filled, and a test matrix will be completed in early FY2024.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluation of Foster Dam Juvenile Fish Passage, 2018 (Final Report)

This report presents the results of a fish passage study conducted by the Pacific Northwest National Laboratory (PNNL) for the U.S. Army Corps of Engineers Portland District (USACE) at Foster Dam (herein, Foster) during the spring (March–June) and fall (October–December) of 2018. The goal of this study was to provide biologists, engineers, resource managers, and regional decision-makers with information about passage of juvenile Chinook salmon and juvenile steelhead (or appropriate surrogates) through specific routes at Foster. The results of this study are intended to help facilitate decision-making regarding long-term measures for enhancing salmonid passage at Foster. Radio telemetry (RT) methods were instituted at low winter reservoir forebay elevation (low pool, 613 ft mean sea level (msl); spring 2018 and fall 2018) and high summer reservoir forebay elevation (high pool, 635 ft msl; late spring and early summer 2018) to accomplish the following objectives: I. Estimate the following passage metrics under typical operations (i.e., baseline conditions): a. Overall dam-passage survival and survival specific to each route of dam passage, calculated using two different methods: i. Cormack-Jolly-Seber (CJS) estimate: Probability of survival from dam passage to detection at the Primary Array, 19 river kilometers (rkm) downstream of Foster. ii. Virtual Release/Dead Fish Correction (ViRDCt) estimate: Corrects the bias that occurs from misidentifying fish that did not survive dam-passage as alive at the tailrace Egress Array, allowing an estimate of survival from dam passage to this array, 2.5 rkm downstream of Foster. b. Route distribution (passage proportions by route; also known as “passage efficiencies”). c. Efficiency metrics i. Dam-passage efficiency (DPE), the proportion of total fish passing the dam relative to the number of total fish detected in the near forebay of the dam and therefore available to pass. ii. Fish passage efficiency (FPE), the proportion of fish passing via a non-turbine route, relative to the number of total fish in the near forebay and available to pass. iii. Fish weir efficiency (FWE) and spill bay efficiency (SBE), the proportion of fish passing the weir or spill bays, respectively, relative to the total number of fish passing the dam. d. Reservoir residency time (time elapsed between release into reservoir and dam passage) and travel times through the system. II. Estimate efficiency and effectiveness of the new fish weir, compared to the turbines and the spillway. III. Under alternative operations, compare passage through each route (turbines, weir, spillway) using a block/treatment (on/off) design similar to the 2015 and 2016 studies. IV. Estimate efficiency of the new fish weir operating at a low level of discharge (< 500 cfs) and a high level of discharge (= 500 cfs), as well as dam passage survival at each weir discharge level. V. Evaluate survival and behavior of hatchery summer steelhead to wild surrogate winter steelhead for potential use of summer steelhead as a surrogate species winter steelhead. VI. Evaluate juvenile passage rates in the auxiliary water supply (AWS), forebay water supply (FWS), and hatchery water supply (HWS).

54 ENVIRONMENTAL SCIENCES↗

Computational Analysis of Hydraulic Efficiency of Michigan DOT Cover C

Drainage structures are used to capture stormwater runoff in streets and highways in urban environments. These drainage structures, which typically consist of catch basins with grates, inlets, or combination grates/inlets, collect stormwater runoff and discharge through buried conveyance systems. They are strategically placed for public safety in curb and gutter systems to provide efficient drainage of water from roadways and thus reduce the risk of hydroplaning. The performance of drainage structures is measured in terms of hydraulic efficiency, which is defined as the percentage of flow captured by the basin as compared to the total flow drainage to the structure. Understanding of the performance of these drainage structures helps designers properly space inlets to promote an economic design that ensures the safety of the traveling public. The current design methodology used to determine drainage structure follows guidelines established in the current Michigan Department of Transportation (MDOT) Drainage Manual (2006). The guidelines in the MDOT Drainage Manual were modeled after the Federal Highway Administration’s (FHWA) Hydraulic Engineering Circular 22 “Urban Drainage Design” (HEC-22). HEC-22 includes empirically derived equations to calculate the interception capacity of drainage structures for several commonly used grate configurations, such as the parallel bar, curved vane and tilt bar grates, which are based on a research study performed by Burgi et al. in the 1970s. MDOT uses several drainage structures to capture runoff that are detailed as Standard Plans. Many of these drainage structures utilize sinusoidal type grates that are not described in HEC-22. Physical modeling of these structures has been limited, posing the need to have them analyzed to verify their capture efficiency. Current MDOT practice is to assume a similar sized reticuline grate, as described in HEC-22, for capture efficiencies. Until recently, evaluating the hydraulic performance of drainage structures was limited to physical modeling in a hydraulics laboratory. With advances in engineering software and computing power, computational fluid dynamics (CFD) modeling has become a more cost-effective alternative. The Federal Highway Administration (FHWA) provides states the option to evaluate their drainage structures using CFD through the Transportation Pooled Fund Program. This study, “Computational Analysis of Hydraulic Efficiency of Michigan DOT Cover C,” was carried out using the pooled fund. MDOT’s Cover C was chosen as the first test candidate, given its similar sinusoidal pattern to other MDOT grates, but it is typically used for high-volume, higher speed applications. A similar version, Cover CX, is used on interstate highways but does not have traverse bars for bicycle safety. Additional grates may be considered for evaluation in the future.

42 ENGINEERING↗

Model-based quantification of margins and uncertainties in metal additive manufacturing for process design and qualification

Laser powder bed fusion (LPBF) Additive Manufacturing (AM) has the potential to enable the production of components with novel designs and material properties unachievable otherwise. However, process repeatability is a challenge, making qualification ill-defined and greatly reducing the utility of what could be an important manufacturing technology. In this work, a combination of modeling, uncertainty quantification (UQ), and experimentation are used in an effort to predict and bound the range of possible outcomes of the LPBF process. Quantities of interest predicted are melt pool dimensions, microstructure features, and mechanical distortions. A combination of high fidelity thermal-fluid models, microstructure growth models, and reduced fidelity, rapid thermal and mechanical models are used. Uncertainty propagation techniques are used to predict probability distributions of quantities of interest from estimates of process uncertainties. Repeated experiments are done to quantify observed probability distributions and compared to predicted distributions to determine if predictions are precise and accurate. Novel modeling methods are microstrucutre characterization techniques are also discussed. It is found that high fidelity models do a generally good job bounding experimentally observed melt pool morphologies for both bead-on-plate and powder bed cases. Microstructure models are able to bound a number of experimentally observed microstructure statistics, but with low precision due to challenges with calibrating the microstructure growth model parameters. A developed modified inherent strain distortion model does not accurately predict observed distortions. A lumped laser distortion model shows promise in being both accurately and precisely bounding observed outcomes from the deflection comb build, but requires further evaluation on more builds and geometries.

36 MATERIALS SCIENCE↗

High-Speed and High-Quality Field Welding Repair Based on Advanced Non-Destructive Evaluation and Numerical Modeling

Creep strength-enhanced ferritic (CSEF) steels such as Grade 91 (9Cr-1Mo-V) and Grade 92 (Fe-9Cr-2W-0.5Mo) steels are widely used in the fossil-fuel-fired and nuclear power plants. The weld integrity of these steels is crucial for power plants' safe and reliable operations. Due to harsh service conditions, the steel weld can become susceptible to environmental degradation. Field welding repair is used to restore the degraded weld’s performance where a controlled temper-bead welding technique is commonly used to temper the freshly formed martensite during welding. However, knowledge of weld repairability is limited and experimental trial and error optimization to achieve desired microstructure and joint properties is expensive and time-consuming. Many existing computational models, e.g., finite element models, are limited to solving heat conduction equation and ignoring convective heat transfer due to molten metal flow. These models can result in over-prediction of peak temperatures of weld pool and heat-affected zone (HAZ), which in turn can affect the accuracy of tempering prediction. Moreover, these finite element models require an input of the deposit profiles in advance and thus limits the usability of these models. Here, a molten pool-based, multi-pass multi-layer model has been developed based on computational fluid dynamics (CFD) approach with the Volume of Fluid (VOF) method. The model calculates the bead formation, thereby eliminating the need for pre-determined bead profiles required by finite element models. For computational efficiency, a coordinate system attached to the moving heat source is utilized. A subroutine is developed to convert the temperature profiles in the reference frame stationary to the heat source to that stationary to the workpiece. The converted thermal cycles are then imported into a microstructure model to compute the tempering kinetics and resultant hardness using a Johnson-Mehl-Avrami-Kolmogorov (JMAK), and modified Grange-Baughman parameter. The modeling approach is first developed and validated on single- and multi-pass deposition of stainless steel filler metal onto a SA-533 high strength steel substrate. The models are then applied to a multi-pass V-groove repair weld of Grade 91 steel plate as well as directed energy deposition of Grade 92 steel. Non-destructive characterization of microstructures was performed on Grade 91 and 92 steel welds. Two welding processes, cold metal transfer (CMT) and flux-cored arc welding (FCAW), were investigated for the Grade 91 steel weld samples. For the Grade 92 weld samples, three different heat inputs (low, medium, and high) of gas tungsten arc welding (GTAW) were utilized to replicate traditional field welding processes. The non-destructive evaluation (NDE) method used for this research was immersion ultrasonic testing (UT) using a micro-resolution ultrasonic imaging methodology specifically designed to operate in the through-transmission configuration operating at 20 MHz of frequency. The system used a focused ultrasonic beam spot size diameter between 250-300 μm, and a 6 μm laser vibrometer spot size for detection, to produce highly defined images with longitudinal and mode-converted shear waves. From the micro-resolution ultrasonic C-scan images, three microstructural regions, i.e., weld metal (WM), HAZ, and base metal (BM), were clearly identifiable. Various levels of ultrasonic amplitudes distributed over the three regions were correlated with electron beam backscattered diffraction (EBSD) images using grain size, grain boundaries, and dislocation densities. The results showed that areas with relatively higher ultrasonic amplitude levels were associated with smaller grains and higher dislocation densities, while areas with lower amplitude levels were associated with larger grains and lower dislocation densities. In addition, ultrasonic velocity data obtained across the three different weld microstructural regions of Grade 91 test samples were correlated with optical metallographic images and hardness measurements. The results showed distinctive decreases in ultrasonic velocity and hardness over the HAZ region, where weld failures often occur during service.

36 MATERIALS SCIENCE↗

Management of the Three Mile Island, Unit 2, Accident Corium and Severely Damaged Fuel Debris

The Three Mile Island, Unit Two (TMI-2) pressurized water reactor core melted down in 1979 due to an untimely combination of maintenance problems that led to a loss of feedwater, followed by a series of operational misunderstandings and errors. The melted core recovery process required development of a wide array of tools. After approximately three years of water management and other cleanup actions, the first views of the core revealed a much higher degree of damage than previously expected. Approximately 62 metric tons of the core had melted, leaving only 42 of the 177 fuel assemblies standing with a majority of rods intact. The core to be recovered was composed of loose debris and a solidified mass of formerly molten fuel. Robotic tools that had been designed for the task were of limited effectiveness due to the range of material types and phases. Over a period of several years, the central melt was broken up, primarily by use of a core-boring drill originally designed to acquire samples through the depth of the debris field. The broken pieces were loaded into specially designed debris canisters by use of long-handled pick-and-place tools and suctioned into baffled knockout canisters using an airlift vacuum system. A remotely operable underwater plasma arc torch was developed for removal of the lower core support structure to be able to retrieve the fuel pieces and secondary melt that had accumulated on the bottom reactor vessel head. Canister design played a central role in defining the initial retrieval process and later affected transportation, interim wet and its current interim dry storage. Due to concerns about the potential for radiolysis of residual water in the debris and other canister material, the canisters were fitted with hydrogen recombiner catalyst units to prevent a buildup of flammable gas and potential pressurization. To confirm the effectiveness of the recombiners during shipping, eight dewatered canisters were kept sealed for up to 205 days with periodic sampling of the headspace gas. The highest hydrogen value (9 vol%) was observed in a canister held for 147 days while the longest stored canister resulted in a 5% hydrogen concentration. The oxygen concentration never exceeded 0.5 %, and the primary backfill was >80% argon, meaning there was no flammability risk. Radiolytic hydrogen was also observed in wet pool storage, where the vented canisters discharged a portion of the water backfill as a result of gas production. The 344 canisters (268 fuel debris, 62 filter, and 12 knockout type) were dewatered, loaded in groups of seven into a double barrier shipping cask, and transported to the U.S. Department of Energy site in Idaho for 10 years of pool storage.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ICE Calculator 2.0: Final Report for Phase 1 of the National Initiative to Update the Interruption Cost Estimate (ICE) Calculator

In 2021, Berkeley Lab and Resource Innovations, Inc. launched the “ICE 2.0 Initiative” – a national study to refresh the underlying data and enhance the functionality of the ICE Calculator. The Initiative involves Berkeley Lab contracting with sponsoring utilities to administer identical, updated and comprehensive interruption cost surveys to statistically representative samples of each utility’s customers. Berkeley Lab and Resource Innovations then pool the survey results across the utilities and use them to update the analytical engines that drive the ICE Calculator. The ICE 2.0 Initiative is being conducted in phases. Each phase involves the administration of interruption cost surveys to the customers of sponsoring utilities, followed by an update to the ICE Calculator based on analysis of the pooled survey results. This report describes the activities and findings from Phase 1 of the ICE 2.0 Initiative. Phase 1 was sponsored by eight utilities: American Electric Power, Commonwealth Edison, Dominion Energy, Duke Energy, DTE Electric, Exelon, National Grid, and Puget Sound Energy. Phase 1 involved 11 customer interruption cost survey activities representing a total of 24 electricity distribution service territories, 23 of them located in the Eastern and Midwestern regions of the U.S. and one located in the Pacific Northwest. ICE 2.0 vs. 1.0 Comparison This memorandum compares customer power interruption costs estimated using the recently updated Interruption Cost Estimate (ICE) Calculator (“ICE 2.0”) to the original ICE Calculator (“ICE 1.0”). ICE 1.0 was developed in 2009 based on 15 independent power interruption cost surveys conducted by 10 electric utilities between 1989 and 2012. ICE 2.0 was developed in 2025 through a national initiative based on a consistent set of power interruption cost surveys and 11 surveying efforts conducted across 24 electric utility service territories between 2022 and 2024.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Identify and Assess Technical Challenges in Safeguards Measurements of Spent Advanced Reactor Fuels

Advanced reactor (AR) designs use various nuclear fuel types that can be significantly different than conventional light-water reactor (LWR) fuels, including differences in sizes, compositions, and chemical forms (e.g., oxide, carbide, metal). Nearly all the proposed AR fuels use high-assay low-enriched uranium (HALEU), which will have higher enrichments (5–20 wt% 235 U) than LWR fuels (currently limited to <5 wt% 235 U). In advance of the wide use of these new fuel types around the world, international safeguards organizations such as the International Atomic Energy Agency (IAEA]) are working with some of the AR vendors to formulate safeguards approaches for these AR fuel cycles. As part of the overall safeguards approach, it is important to identify the potential technical challenges in performing safeguards verification measurements of these AR fuels (both fresh and spent fuels) in advance of the widespread adoption of these new fuel types, because new safeguards technologies can take several years to develop, test, and approve for use. This report documents work performed in fiscal year 2024 based on modeling and simulation to assess the performance of the existing safeguards measurement technologies for irradiated or spent AR fuel elements or items. This work is a continuation of the work performed in fiscal year 2023 that focused on fresh AR fuels. Spent AR fuels have a distinct difference from their LWR counterparts: unlike the spent LWR fuels typically stored in a water-filled pool, some spent AR fuels—such as tristructural-isotropic (TRISO)-based fuels—will most likely be stored in air-filled hot cells. Because most safeguards measurements on spent fuel performed to date have been conducted under water, the air-filled hot cell environment could present unique challenges to safeguards measurements. Fork detector (FDET) and Cerenkov viewing device (CVD) systems have been the two primary instruments used by the IAEA for several decades to measure spent LWR fuel assemblies stored in pools for safeguards verification purposes. Because the lower refractive index of air causes Cerenkov light to be of lower intensity in air than in water, existing CVDs are likely unable to perform safeguards verification measurements for spent fuel stored in an air-filled hot cell, as is the case for the TRISO-based spent fuel elements (e.g., pebbles, graphite fuel blocks). Unlike FDET measurements, CVD measurements do not require fuel be moved, so they are a simpler and faster to take than FDET measurements. The inability to perform CVD measurements on the TRISO-based AR fuel types presents a major technical challenge in the effort to use existing technology to perform safeguards measurements on spent AR fuels. This study was mainly conducted through the modeling and simulation of an FDET or an FDET-like system on five spent AR fuel types, including one metallic fuel type and four TRISO-based fuel types in both pebble and graphite block forms in their respective storage configurations and environments. Because the various AR fuel types have significantly different dimensions, FDET systems must be adapted to accommodate them. Partial defect tests were also simulated in this study to assess the FDET’s ability to detect potential fuel diversions. The FDET measures the fuel’s total passive neutron and gamma emissions. The simulated FDET results from spent AR fuel items are compared against results from a typical spent pressurized water reactor (PWR) assembly. High-purity germanium (HPGe) gamma detector measurements were also simulated for the spent AR fuel types and the PWR assembly because the signature photopeaks have been used in LWR safeguards verifications, although HPGe is usually not used to detect diversions because of the fuel’s self-attenuation effects on those photopeaks. The results indicate that these detectors have significant challenges in performing safeguards measurements of the spent AR fuel items, including incompatibilities between AR fuel items and existing FDETs, lower neutron count rates, lower sensitivities to fuel diversions in certain AR fuel items, and significantly higher interference from a neighboring fuel item when the measurement is performed in air. These results suggest that an alternative technology or significant and timely technology development is needed to perform adequate safeguards measurements of some of these AR fuel items.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Report on Retrieval of the Reactor Pressure Vessel A-60 Surveillance Capsule from Palisades Nuclear Generating Station

Located on the shores of Lake Michigan, the Palisades Nuclear Generating Station (PNGS) was a nuclear power plant that operated in Covert Township, Michigan. The plant had a single pressurized water reactor that produced electricity for the region. The PNGS was shut down in 2022 after more than four decades of service. The PNGS included in its surveillance program a surveillance capsule, designated A-60, containing specimens of a weld metal with nickel content of about 1.36 wt% and copper content of about 0.20 wt%. The capsule was removed from its surveillance position in the early 1995 and has been resident in the spent fuel pool since that time. This capsule was irradiated to a fluence of 1.87×10 20 n/cm 2 (E> 1MeV) that is equivalent for more than 120 effective full power year (EFPY) for the US reactor pressure vessel (RPV) fleet. The material is also of special interest because of its very high nickel content and potential for development of NiMnSi (nickel-manganese-silicon) precipitates. Combination of very high fluence and very high Ni and Cu content makes the material in this capsule of the great interest as benchmark for currently developing embrittlement trend curves (ETC) aiming to predict embrittlement at high fluences. Thus, several years ago the Light Water Reactor Sustainability Program (LWRSP) initiated negotiations with Entergy to harvest this high fluence capsule since it did not present any regulatory interest for PNGS but could play a very important role for LWRSP efforts for developing ETC for very long-term operation. The negotiations resumed once PNGS ownership moved to the Holtec International in June 2022 which was very supportive to the LWRSP efforts to harvest the A-60 capsule from the spent fuel pool. As a result, the contract was placed with the Westinghouse Electric Company (WEC) to come to PNGS site, retrieve the A-60 capsule, bring it to WEC Churchill hot cell facility, open the capsule and send all surveillance specimens in the capsule to ORNL for future characterization. These specimens from the PNGS A-60 capsule have arrived to ORNL in July 2023 and this report summarizes activities to retrieve and deliver specimens to ORNL site for future evaluation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Interactions Between Clouds and Wind-Driven Surface Heat Exchanges over Land

Earth system model experiments show that increasing horizontal resolution fundamentally alters the simulated soil-moisture-precipitation feedback. Kilometer-scale simulations often produce weaker or even negative feedback compared to coarse-resolution models. A key difference of kilometer-scale models is that they resolve mesoscale secondary circulations, including boundary layer horizontal rolls and cellular structures, in addition to cold pools and downdrafts associated with convective precipitation. However, because the relevant processes occur on yet-smaller scales, these circulations are often poorly resolved. This project demonstrated that boundary layer secondary circulations significantly affect surface heat exchanges and wind gusts, and that current model parameterizations can misrepresent these processes at kilometer-scale resolution. Using DOE Atmospheric Radiation Measurement (ARM) observations and targeted experiments with the DOE Energy Exascale Earth System Model (E3SM), we identified physically unrealistic wind gust and surface flux responses to secondary circulations, diagnosed a systematic overestimation of wind shear in convective cold pools, and uncovered a multivariate relationship between land surface fluxes and the scales of updrafts that form shallow cumulus clouds. These findings provide observation-based recommendations for improving parameterizations of surface fluxes and wind gusts in high-resolution Earth system models, thereby reducing uncertainty in convective storm prediction and land-atmosphere feedbacks.

54 ENVIRONMENTAL SCIENCES↗

Low-cost and high-performance heat exchangers for CSP

This project aimed to design and manufacture a low-cost and high-performance, particle–to–sCO 2 heat exchanger (HX) for Concentrated Solar Power (CSP) using additive manufacturing (AM). Three enabling technologies will be integrated to achieve the targeted cost and performance. The first technology is the extreme high‐speed laser materials deposition (LMD) AM process known by its German acronym EHLA that was invented at the Fraunhofer Institute for Laser Technology. The EHLA process utilizes a specially designed powder-feeding nozzle that enables a laser to melt the powder particles above the melt pool, in contrast to the conventional LMD process where the powders are melted inside the melt pool. EHLA enables much faster deposition rate than conventional LMD without the need to wait for the powders to melt. The second technology is an innovative double-helical HX geometry that can be easily fabricated using the EHLA process by rotating a rod at a high-speed to take advantage of the high EHLA deposition rate. The double-helical fins separate the hot region (the hot particle side) and the cold region (the sCO 2 side) and provide large heat transfer surface area without a large pressure drop on the sCO 2 side. The particle side will have a larger gap to facilitate the particle flow. The outer rims of the double helixes can be sealed off using the same AM process. After sealing-off, additional double helixes can be built radially on top of the first set to improve HX performance. The HX can be installed vertically for gravity-driven flow of the hot particles if necessary. The third technology is a low-cost high-temperature alumina-forming austenitic (AFA) steel TMA-6350 that has creep and oxidation resistance up to 1100 °C. These technologies together will enable high-performance and low-cost HXs for particle–to–sCO 2 for CSP.

14 SOLAR ENERGY↗

Development of Industrial Scale Rare Earth Master Alloys from Their Native Oxides for Magnet Production

The objective of the project is to develop an energy-efficient, reduced cost, and single-step critical metal oxide reduction and alloying methodology for the production of NdFeB and SmCo magnets to facilitate the establishment of a sustainable domestic critical materials supply chain. The method consists of an immiscible molten salt flux layer and a higher density molten metal alloy pool (FeB or Co). The rare earth (RE) oxide and a reductant are added to the molten salt layer, where the reductant first strips the oxygen from the rare earth oxide. Subsequently, the separated RE metal diffuses into the molten metal pool below, creating a RE-saturated master alloy. Towards this end, thermodynamic calculations of the reactions between RE oxides, metallic reducing agent, and molten salt bath chemistry have been performed, and the ideal feeds and conditions for extraction and diffusion to produce master alloys were established. Small-scale and scaled experimentation was performed to validate and optimize the feasibility of viable reactions, temperatures, and process conditions with regards to yield, composition, and process efficiency. Finally, full-scale experiments for the production of NdFeB and SmCo magnets were performed, and their performance characteristics were established.

36 MATERIALS SCIENCE↗

ICE Calculator 2: Final Report for Phase 1 and 2 of the National Initiative to Update the Interruption Cost Estimate (ICE) Calculator

ICE 2.0 Phase 2 Final Report In 2021, Berkeley Lab and Resource Innovations, Inc. launched the “ICE Calculator 2 Initiative” – a national study to refresh the underlying data and enhance the functionality of the ICE Calculator. The Initiative involves Berkeley Lab contracting with sponsoring utilities to administer identical, updated and comprehensive interruption cost surveys to statistically representative samples of each utility’s customers. Berkeley Lab and Resource Innovations then pool the survey results across the utilities and use them to update the analytical engines that drive the ICE Calculator. The ICE Calculator 2 Initiative is being conducted in phases. Each phase involves the administration of interruption cost surveys to the customers of sponsoring utilities, followed by an update to the ICE Calculator based on analysis of the pooled survey results. This report describes the activities and findings from Phase 1 and 2 of the ICE Calculator 2 Initiative. Phase 1 was sponsored by eight utilities: American Electric Power, Commonwealth Edison, Dominion Energy, Duke Energy, DTE Electric, Exelon, National Grid, and Puget Sound Energy. Phase 2 was sponsored by six utilities: Empire District Electric Company, Evergy Missouri, Pacific Gas & Electric, San Diego Gas & Electric, Southern California Edison, and Union Electric. Phase 1 and 2 involved 15 customer interruption cost survey activities representing a total of 30 electricity distribution service territories. ICE Calculator Version 2.0 and 2.2 Comparison This memorandum describes–at a high-level–the improvements in interruption cost estimates for the version 2.2 of the ICE Calculator (released February 2026) compared to version 2.0 (released in April 2025). Version 2.2 of the ICE Calculator corresponds to Phase 2 of the initiative, while version 2.0 corresponds to Phase 1. The improvements in version 2.2 result from both a significant increase in the number of customer responses that have been collected and the identification of seven additional factors that help estimate customer interruption costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DAOS Benchmarks and Findings

We benchmark DAOS on a 127-node, 4,064-target pool using fio, IOR, IO500, and mdtest, comparing the DFS API against DFuse+POSIX. Single-client fio sweeps show larger block sizes and writes yield higher bandwidth, with similar random/sequential performance. Multi-node IOR (1–32 nodes, 6–48 tasks/node) shows bandwidth saturating around 32 tasks/node, with large transfer sizes hurting read throughput at high concurrency and write latency growing faster than read latency. An 8-node IO500 run shows DFS achieving ~5x higher bandwidth and ~190x higher IOPS than POSIX. We also detail operational issues: SCM target-filling under mdtest, intermittent NA_HOSTUNREACH errors, fio CPU-affinity failures, and a pool error storm resolved by recreation.

George, Rebecca [Thomas Jefferson National Acceler↗

Experimental and Thermalhydraulic Code Assessment of the Transient Behavior of the Passive Condenser System in an Advanced Boiling Water Reactor

The main goal of the project was to study analytically and experimentally the condensation heat transfer for the passive condenser system such as GE Economic Simplified Boiling Water Reactor (ESBWR). The effect of noncondensable gas in condenser tube and the reduction of secondary pool water level to the condensation heat transfer coefficient was the main focus in this research. The objectives of this research were to : 1) obtain experimental data on the local and tube averaged condensation heat transfer rates for the PCCS with non-condensable and with change in the secondary pool water, 2) assess the RELAP5 and TRACE computer code against the experimental data, and 3) develop mathematical model and ehat transfer correlation for the condensation phenomena for system code application. The project involves experimentation, theoretical model development and verification, and thermal- hydraulic codes assessment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of a Safeguards Verification Method and Instrument to Detect Pin Diversion from Pressurized Water Reactor (PWR) Spent Fuel Assemblies Phase I Study

A novel methodology to detect diversion of spent fuel from Pressurized Water Reactors (PWR) has been developed in order to address a long unsolved safeguards verification problem for international safeguards community such as International Atomic Energy Agency (IAEA) or European Atomic Energy Community (EURATOM). The concept involves inserting tiny neutron and gamma detectors into the guide tubes of a spent fuel assembly and measuring the signals. The guide tubes form a quadrant symmetric pattern in the various PWR fuel product lines and the neutron and gamma signals from these various locations are processed to obtain a unique signature for an undisturbed fuel assembly. Signatures based on the neutron and gamma signals individually or in a combination can be developed. Removal of fuel pins from the assembly will cause the signatures to be visibly perturbed thus enabling the detection of diversion. All of the required signal processing to obtain signatures can be performed on standard laptop computers. Monte Carlo simulation studies and a set of controlled experiments with actual commercial PWR spent fuel assemblies were performed and validated this novel methodology. Based on the simulation studies and benchmarking measurements, the methodology developed promises to be a powerful and practical way to detect partial defects that constitute 10% or more of the total active fuel pins. This far exceeds the detection threshold of 50% missing pins from a spent fuel assembly, a threshold defined by the IAEA Safeguards Criteria. The methodology does not rely on any operator provided data like burnup or cooling time and does not require movement of the fuel assembly from the storage rack in the spent fuel pool. A concept was developed to build a practical field device, Partial Defect Detector (PDET), which will be completely portable and will use standard radiation measuring devices already in use at the IAEA. The use of the device will not require any information provided by the operator or any prior knowledge of the spent fuel assembly. The device can also be operated without any movement of the spent fuel from its storage position. Based on parametric studies conducted via computer simulation, the device should be able to detect diversion of as low as ten percent of the missing or replaced fuel from an assembly regardless of the location of the missing fuel within the assembly, of the cooling time, initial fuel enrichment or burnup levels. Conditions in the spent fuel pool such as clarity of the water or boron content are also not issues for this device. The shape of the base signature is principally dependent on the layout of the guide tubes in the various types of PWR fuel assemblies and perturbations in the form of replaced fuel pins will distort this signature. These features of PDET are all unique and overcome limitation and disadvantages presented by currently used devices such as the Fork detector or the Cerenkov Viewing Device. Thus, this device when developed and tested could fill an important need in the safeguards area for partial defect detection, a technology that the IAEA has been seeking for the past few decades.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗