Search NASA⌕ Search

SEARCH · Search NASA

Results for “projection method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

An Infrared Spectral Database for Detection of Gases Emitted by Biomass Burning

We report the construction of a database of infrared spectra aimed at detecting the gases emitted by biomass burning (BB). The project uses many of the methods of the Pacific Northwest National Laboratory (PNNL) infrared database, but the selection of the species and special experimental considerations are optimized. Each spectrum is a weighted average derived from 10 or more individual measurements. Each composite has a spectral range from ≤ 600 cm-1 to ≥ 6500 cm-1 with an instrumental apodized resolution of 0.11 cm-1. The resolution was chosen to bring out all spectral features, but recognizing that pressure broadening at 760 Torr results in essentially all ro-vibrational lines having these or greater linewidths.

09 BIOMASS FUELS↗

Projection-Based Correlated Wave Function in Density Functional Theory Embedding for Periodic Systems

In this report we present a level shift projection operator-based embedding method for systems with periodic boundary conditions—where the “active” subsystem can be described using either density functional theory (DFT) or correlated wave function (WF) methods and the “environment” is described using DFT. Our method allows for k-point sampling, is shown to be exactly equal to the canonical DFT solution of the full system under the limit that we use the full system basis to describe each subsystem, and can treat the active subsystem either with periodic boundary conditions—in what we term “periodic-in-periodic” embedding—or as a molecular cluster—in “cluster-in-periodic” embedding. We explore each of these methods and show that cluster WF-in-periodic DFT embedding can accurately calculate the absorption energy of CO on to a Si(100)-2×1 surface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Unsupervised Clustering of Microseismic Events and Focal Mechanism Analysis at the CO 2 Injection Site in Decatur, Illinois

Characterization of induced microseismicity at a carbon dioxide (CO 2 ) storage site is critical for preserving reservoir integrity and mitigating seismic hazards. We apply a multilevel machine learning (ML) approach that combines the nonnegative matrix factorization and hidden Markov model to extract spectral representations of microseismic events and cluster them to identify seismic patterns at the Illinois Basin-Decatur Project. Unlike traditional waveform correlation methods, this approach leverages spectral characteristics of first arrivals to improve event classification and detect previously undetected planes of weakness. By integrating ML-based clustering with focal mechanism analysis, we resolve small-scale fault structures that are below the detection limits of conventional seismic imaging. Our findings reveal temporal bursts of microseismicity associated with brittle failure, providing insights into the spatio-temporal evolution of fault reactivation during CO 2 injection. This approach enhances seismic monitoring capabilities at CO 2 injection sites by improving fault characterization beyond the resolution of standard geophysical surveys.

Willis, Rachel Marie [Sandia National Laboratories↗

Single-shot tomographic movies of evolving light-velocity objects

Tomography—cross-sectional imaging based on measuring radiation transmitted through an object along different directions—enables non-invasive imaging of hidden stationary objects, such as internal bodily organs, from their sequentially measured projections. Here we adapt tomographic methods to visualize—in one laser shot—the instantaneous structure and evolution of a laser-induced object propagating through a transparent Kerr medium. We reconstruct ‘movies’ of a laser pulse’s diffraction, self-focusing and filamentation from phase ‘streaks’ imprinted onto probe pulses that cross the main pulse’s path simultaneously at different angles. Multiple probes are generated and detected compactly and simply, making the system robust, easy to align and adaptable to many problems. Our technique could potentially visualize, for example, plasma wakefield accelerators, optical rogue waves or fast ignitor pulses, light-velocity objects, whose detailed space–time dynamics are known only through intensive computer simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Smart quantum statistical imaging beyond the Abbe-Rayleigh criterion

The wave nature of light imposes limits on the resolution of optical imaging systems. For over a century, the Abbe-Rayleigh criterion has been utilized to assess the spatial resolution limits of imaging instruments. Recently, there has been interest in using spatial projective measurements to enhance the resolution of imaging systems. Unfortunately, these schemes require a priori information regarding the coherence properties of “unknown” light beams and impose stringent alignment conditions. Here, we introduce a smart quantum camera for superresolving imaging that exploits the self-learning features of artificial intelligence to identify the statistical fluctuations of unknown mixtures of light sources at each pixel. This is achieved through a universal quantum model that enables the design of artificial neural networks for the identification of photon fluctuations. Our protocol overcomes limitations of existing superresolution schemes based on spatial mode projections, and consequently provides alternative methods for microscopy, remote sensing, and astronomy.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The first high-redshift cavity power measurements of cool-core galaxy clusters with the International LOFAR Telescope

Radio-mode feedback associated with the active galactic nuclei (AGNs) at the cores of galaxy clusters injects a large amount of energy into the intracluster medium (ICM), offsetting radiative losses through X-ray emission. This mechanism prevents the ICM from rapidly cooling down and fueling extreme starburst activity as it accretes onto the central galaxies, and it is therefore a key ingredient in the evolution of galaxy clusters. However, the influence and mode of feedback at high redshifts (z ∼ 1) remains largely unknown. Low-frequency sub-arcsecond-resolution radio observations taken with the International LOFAR Telescope have demonstrated their ability to assist X-ray observations with constraining the energy output from the AGNs (or “cavity power”) in galaxy clusters, thereby enabling research at higher redshifts than before. In this pilot project, we tested this hybrid method on a high-redshift (0.6 < z < 1.3) sample of 13 galaxy clusters for the first time with the aim of verifying the performance of this method at these redshifts and providing the first estimates of the cavity power associated with the central AGN for a sample of distant clusters. We were able to detect clear radio lobes in three out of 13 galaxy clusters at redshifts of 0.7 < z < 0.9, and we used these detections in combination with ICM pressures surrounding the radio lobes obtained from standard profiles to calculate the corresponding cavity powers of the AGNs. Combining our results with the literature, the current data appear to suggest that the average cavity power peaked at a redshift ofz ∼ 0.4 and slowly decreases toward higher redshifts. However, we require more and tighter constraints on the cavity volume and a better understanding of our observational systematics to confirm any deviation of the cavity power trend from a constant level.

Astronomy & Astrophysics↗

Proton Beam Formation at Fermilab for mu2e (and for NF/MC)

Proton bunch formation from the Fermilab proton sources for the mu2e experiment is discussed. In the initial scenario a single intense h = 1 bunch is formed in the Accumulator/Debuncher, with slow extraction providing the required spill. However, the mu2e experiment could use h = 4 bunching in the Accumulator rather than h = 1, with the 4 bunches fed one at a time into the more isochronous Debuncher for slow extraction. The h = 4 variant has several advantages and a few disadvantages, and can reduce peak beam intensities, and therefore improve space charge limits. The method can be extended to project X to enable high duty cycle extraction within space charge limits. A further extension should make possible an accumulator/buncher scenario that can provide 8 GeV short bunches for a neutrino factory and/or muon collider scenario.

43 PARTICLE ACCELERATORS↗

Comparison of One- and Two-Variable Linear Regression Models and Classic Energy Intensity for Energy Performance Tracking of Two Manufacturing Sectors

We report manufacturing facilities consumed about 32% of total domestic energy in the United States in 2016. To evaluate the energy savings achieved through the implementation of energy conservation projects and to establish powerful arguments for future projects, accurate energy performance tracking methods are necessary. The classic energy intensity method (i.e., the ratio of annual total energy over annual total production) is the means most widely used to measure savings because it can be understood and calculated easily. This method considers the variation in production rates to some extent; however, it fundamentally assumes facilities' base energy consumption (energy consumption at zero production) to be zero, which rarely holds true. Furthermore, this method does not consider variations in other relevant parameters, such as weather conditions. Therefore, the regression models approach is commonly recommended to track energy performance improvements. However, because it requires more data and statistical expertise, the regression models approach has been adopted by only a few facilities, and many others suspect it is not worth the effort for their specific cases. For this reason, the improved accuracy this approach offers needs to be demonstrated. By analyzing 477 monthly energy (electricity and natural gas) data sets, this study quantitatively compared the accuracy of classic energy intensity, one-variable (production only) linear regression models, and two-variable (i.e., production and weather) linear regression models for two manufacturing sectors (primary metal and transportation equipment manufacturing). Results showed that significant improvements in accuracy were achieved with one-variable regression models when compared with the classic energy intensity method and with two-variable regression models when compared with one-variable regression models. These improvements were demonstrated using the p values of intercept, cooling degree days, and heating degree days. Based on these results, to achieve a good balance between accuracy improvements and resources requirements, one-variable (production only) linear regression models for electricity consumption and two-variable (production and heating degree days) linear regression models for natural gas consumption are recommended for both sectors in the case of limited resources. Lastly, facilities can also use the results to decide which approaches fit better in their cases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BD+15 2940 AND HD 233604: TWO GIANTS WITH PLANETS CLOSE TO THE ENGULFMENT ZONE

We report the discovery of planetary-mass companions to two red giants by the ongoing Penn State-Torun Planet Search (PTPS) conducted with the 9.2 m Hobby-Eberly Telescope. The 1.1 M{sub Sun} K0-giant, BD+15 2940, has a 1.1 M{sub J} minimum mass companion orbiting the star at a 137.5 day period in a 0.54 AU orbit what makes it the closest-in planet around a giant and possible subject of engulfment as the consequence of stellar evolution. HD 233604, a 1.5 M{sub Sun} K5-giant, is orbited by a 6.6 M{sub J} minimum mass planet which has a period of 192 days and a semi-major axis of only 0.75 AU making it one of the least distant planets to a giant star. The chemical composition analysis of HD 233604 reveals a relatively high {sup 7}Li abundance which may be a sign of its early evolutionary stage or recent engulfment of another planet in the system. We also present independent detections of planetary-mass companions to HD 209458 and HD 88133, and stellar activity-induced radial velocity variations in HD 166435, as part of the discussion of the observing and data analysis methods used in the PTPS project.

79 ASTRONOMY AND ASTROPHYSICS↗

Super-massive planets around late-type stars—the case of OGLE-2012-BLG-0406Lb

Super-Jupiter-mass planets should form only beyond the snow line of host stars. However, the core accretion theory of planetary formation does not predict super-Jupiters forming around low-mass hosts. We present a discovery of a 3.9 ± 1.2 M {sub Jup} mass planet orbiting the 0.59 ± 0.17 M {sub ☉} star using the gravitational microlensing method. During the event, the projected separation of the planet and the star is 3.9 ± 1.0 AU, i.e., the planet is significantly further from the host star than the snow line. This is the fourth such planet discovered using the microlensing technique and challenges the core accretion theory.

79 ASTRONOMY AND ASTROPHYSICS↗

The clustering of DESI-like luminous red galaxies using photometric redshifts

ABSTRACT We present measurements of the redshift-dependent clustering of a DESI-like luminous red galaxy (LRG) sample selected from the Legacy Survey imaging data set, and use the halo occupation distribution (HOD) framework to fit the clustering signal. The photometric LRG sample in this study contains 2.7 million objects over the redshift range of 0.4 < z < 0.9 over 5655 deg2. We have developed new photometric redshift (photo-z) estimates using the Legacy Survey DECam and WISE photometry, with σNMAD = 0.02 precision for LRGs. We compute the projected correlation function using new methods that maximize signal-to-noise ratio while incorporating redshift uncertainties. We present a novel algorithm for dividing irregular survey geometries into equal-area patches for jackknife resampling. For a five-parameter HOD model fit using the MultiDark halo catalogue, we find that there is little evolution in HOD parameters except at the highest redshifts. The inferred large-scale structure bias is largely consistent with constant clustering amplitude over time. In an appendix, we explore limitations of Markov chain Monte Carlo fitting using stochastic likelihood estimates resulting from applying HOD methods to N-body catalogues, and present a new technique for finding best-fitting parameters in this situation. Accompanying this paper, we have released the Photometric Redshifts for the Legacy Surveys catalogue of photo-z’s obtained by applying the methods used in this work to the full Legacy Survey Data Release 8 data set. This catalogue provides accurate photometric redshifts for objects with z < 21 over more than 16 000 deg2 of sky.

79 ASTRONOMY AND ASTROPHYSICS↗

Triaxial superdeformation in {sup 40}Ar

Superdeformed (SD) states in {sup 40}Ar have been studied using the deformed-basis antisymmetrized molecular dynamics. Low-energy states were calculated by the parity and angular momentum projection and the generator coordinate method (GCM). Basis wave functions were obtained by the energy variation with a constraint on the quadrupole deformation parameter beta, while other quantities such as triaxiality gamma were optimized by the energy variation. By the GCM calculation, an SD band was obtained just above the ground-state band. The SD band involves a K{sup p}i=2{sup +} side band due to the triaxiality. The calculated electric quadrupole transition strengths of the SD band reproduce the experimental values appropriately. Triaxiality is significant for understanding low-lying states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

X-ray free-electron laser based dark-field X-ray microscopy: a simulation-based study

Dark-field X-ray microscopy (DFXM) is a nondestructive full-field imaging technique providing three-dimensional mapping of microstructure and local strain fields in deeply embedded crystalline elements. This is achieved by placing an objective lens in the diffracted beam, giving a magnified projection image. So far, the method has been applied with a time resolution of milliseconds to hours. In this work, the feasibility of DFXM at the picosecond time scale using an X-ray free-electron laser source and a pump–probe scheme is considered. Thermomechanical strain-wave simulations are combined with geometrical optics and wavefront propagation optics to simulate DFXM images of phonon dynamics in a diamond single crystal. Using the specifications of the XCS instrument at the Linac Coherent Light Source as an example results in simulated DFXM images clearly showing the propagation of a strain wave.

47 OTHER INSTRUMENTATION↗

Projection Registration Applied to Nondestructive Testing

Registration of radiographic and computed tomography (CT) data has the potential to allow automated metrology and defect detection. While registration of the three-dimensional reconstructed data is a common task in the medical industry for registration of data sets from multiple detection systems, registration of projection sets has only seen development in the area of tomotherapy. Efforts in projection registration have employed a method named Fourier phase matching (FPM). This work discusses implementation and results for the application of the FPM method to industrial applications for the nondestructive testing (NDT) community. The FPM method has been implemented and modified for industrial application. Testing with simulated and experimental x-ray CT data shows excellent performance with respect to the resolution of the imaging system.

47 OTHER INSTRUMENTATION↗

Weighted simultaneous algebraic reconstruction technique for tomosynthesis imaging of objects with high-attenuation features

Purpose: This paper introduces a nonlinear weighting scheme into the backprojection operation within the simultaneous algebraic reconstruction technique (SART). It is designed for tomosynthesis imaging of objects with high-attenuation features in order to reduce limited angle artifacts. Methods: The algorithm estimates which projections potentially produce artifacts in a voxel. The contribution of those projections into the updating term is reduced. In order to identify those projections automatically, a four-dimensional backprojected space representation is used. Weighting coefficients are calculated based on a dissimilarity measure, evaluated in this space. For each combination of an angular view direction and a voxel position an individual weighting coefficient for the updating term is calculated. Results: The feasibility of the proposed approach is shown based on reconstructions of the following real three-dimensional tomosynthesis datasets: a mammography quality phantom, an apple with metal needles, a dried finger bone in water, and a human hand. Datasets have been acquired with a Siemens Mammomat Inspiration tomosynthesis device and reconstructed using SART with and without suggested weighting. Out-of-focus artifacts are described using line profiles and measured using standard deviation (STD) in the plane and below the plane which contains artifact-causing features. Artifacts distribution in axial direction is measured using an artifact spread function (ASF). The volumes reconstructed with the weighting scheme demonstrate the reduction of out-of-focus artifacts, lower STD (meaning reduction of artifacts), and narrower ASF compared to nonweighted SART reconstruction. It is achieved successfully for different kinds of structures: point-like structures such as phantom features, long structures such as metal needles, and fine structures such as trabecular bone structures. Conclusions: Results indicate the feasibility of the proposed algorithm to reduce typical tomosynthesis artifacts produced by high-attenuation features. The proposed algorithm assigns weighting coefficients automatically and no segmentation or tissue-classification steps are required. The algorithm can be included into various iterative reconstruction algorithms with an additive updating strategy. It can also be extended to computed tomography case with the complete set of angular data.

60 APPLIED LIFE SCIENCES↗

CT head-scan dosimetry in an anthropomorphic phantom and associated measurement of ACR accreditation-phantom imaging metrics under clinically representative scan conditions

Purpose: To measure radiation absorbed dose and its distribution in an anthropomorphic head phantom under clinically representative scan conditions in three widely used computed tomography (CT) scanners, and to relate those dose values to metrics such as high-contrast resolution, noise, and contrast-to-noise ratio (CNR) in the American College of Radiology CT accreditation phantom.Methods: By inserting optically stimulated luminescence dosimeters (OSLDs) in the head of an anthropomorphic phantom specially developed for CT dosimetry (University of Florida, Gainesville), we measured dose with three commonly used scanners (GE Discovery CT750 HD, Siemens Definition, Philips Brilliance 64) at two different clinical sites (Walter Reed National Military Medical Center, National Institutes of Health). The scanners were set to operate with the same data-acquisition and image-reconstruction protocols as used clinically for typical head scans, respective of the practices of each facility for each scanner. We also analyzed images of the ACR CT accreditation phantom with the corresponding protocols. While the Siemens Definition and the Philips Brilliance protocols utilized only conventional, filtered back-projection (FBP) image-reconstruction methods, the GE Discovery also employed its particular version of an adaptive statistical iterative reconstruction (ASIR) algorithm that can be blended in desired proportions with the FBP algorithm. We did an objective image-metrics analysis evaluating the modulation transfer function (MTF), noise power spectrum (NPS), and CNR for images reconstructed with FBP. For images reconstructed with ASIR, we only analyzed the CNR, since MTF and NPS results are expected to depend on the object for iterative reconstruction algorithms.Results: The OSLD measurements showed that the Siemens Definition and the Philips Brilliance scanners (located at two different clinical facilities) yield average absorbed doses in tissue of 42.6 and 43.1 mGy, respectively. The GE Discovery delivers about the same amount of dose (43.7 mGy) when run under similar operating and image-reconstruction conditions, i.e., without tube current modulation and ASIR. The image-metrics analysis likewise showed that the MTF, NPS, and CNR associated with the reconstructed images are mutually comparable when the three scanners are run with similar settings, and differences can be attributed to different edge-enhancement properties of the applied reconstruction filters. Moreover, when the GE scanner was operated with the facility's scanner settings for routine head exams, which apply 50% ASIR and use only approximately half of the 100%-FBP dose, the CNR of the images showed no significant change. Even though the CNR alone is not sufficient to characterize the image quality and justify any dose reduction claims, it can be useful as a constancy test metric.Conclusions: This work presents a straightforward method to connect direct measurements of CT dose with objective image metrics such as high-contrast resolution, noise, and CNR. It demonstrates that OSLD measurements in an anthropomorphic head phantom allow a realistic and locally precise estimation of magnitude and spatial distribution of dose in tissue delivered during a typical CT head scan. Additional objective analysis of the images of the ACR accreditation phantom can be used to relate the measured doses to high contrast resolution, noise, and CNR.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-FG-204-08: Optimization-Based Image Reconstruction From Unevenly Distributed Sparse Projection Views

Purpose: Optimization-based reconstruction has been proposed and investigated for reconstructing CT images from sparse views, as such the radiation dose can be substantially reduced while maintaining acceptable image quality. The investigation has so far focused on reconstruction from evenly distributed sparse views. Recognizing the clinical situations wherein only unevenly sparse views are available, e.g., image guided radiation therapy, CT perfusion and multi-cycle cardiovascular imaging, we investigate the performance of optimization-based image reconstruction from unevenly sparse projection views in this work. Methods: The investigation is carried out using the FORBILD and an anthropomorphic head phantoms. In the study, 82 views, which are evenly sorted out from a full (360°) axial CT scan consisting of 984 views, form sub-scan I. Another 82 views are sorted out in a similar manner to form sub-scan II. As such, a CT scan with sparse (164) views at 1:6 ratio are formed. By shifting the two sub-scans relatively in view angulation, a CT scan with unevenly distributed sparse (164) views at 1:6 ratio are formed. An optimization-based method is implemented to reconstruct images from the unevenly distributed views. By taking the FBP reconstruction from the full scan (984 views) as the reference, the root mean square (RMS) between the reference and the optimization-based reconstruction is used to evaluate the performance quantitatively. Results: In visual inspection, the optimization-based method outperforms the FBP substantially in the reconstruction from unevenly distributed, which are quantitatively verified by the RMS gauged globally and in ROIs in both the FORBILD and anthropomorphic head phantoms. The RMS increases with increasing severity in the uneven angular distribution, especially in the case of anthropomorphic head phantom. Conclusion: The optimization-based image reconstruction can save radiation dose up to 12-fold while providing acceptable image quality for advanced clinical applications wherein only unevenly distributed sparse views are available. Research Grants: W81XWH-12-1-0138 (DoD), Sinovision Technologies.

60 APPLIED LIFE SCIENCES↗

WE-DE-207B-11: Implementation of Size-Specific 3D Beam Modulation Filters On a Dedicated Breast CT Platform Using Breast Immobilization

Purpose: To implement a 3D beam modulation filter (3D-BMF) in dedicated breast CT (bCT) and develop a method for conforming the patient’s breast to a pre-defined shape, optimizing the effects of the filter. This work expands on previous work reporting the methodology for designing a 3D-BMF that can spare unnecessary dose and improve signal equalization at the detector by preferentially filtering the beam in the thinner anterior and peripheral breast regions. Methods: Effective diameter profiles were measured for 219 segmented bCT images, grouped into volume quintiles, and averaged within each group to represent the range of breast sizes found clinically. These profiles were then used to generate five size-specific computational phantoms and fabricate five size-specific UHMW phantoms. Each computational phantom was utilized for designing a size-specific 3D-BMF using previously reported methods. Glandular dose values and projection images were simulated in MCNP6 with and without the 3DBMF using the system specifications of our prototype bCT scanner “Doheny”. Lastly, thermoplastic was molded around each of the five phantom sizes and used to produce a series of breast immobilizers for use in conforming the patient’s breast during bCT acquisition. Results: After incorporating the 3D-BMF, MC simulations estimated an 80% average reduction in the detector dynamic range requirements across all phantom sizes. The glandular dose was reduced on average 57% after normalizing by the number of quanta reaching the detector under the thickest region of the breast. Conclusion: A series of bCT-derived breast phantoms were used to design size-specific 3D-BMFs and breast immobilizers that can be used on the bCT platform to conform the patient’s breast and therefore optimally exploit the benefits of the 3D-BMF. Current efforts are focused on fabricating several prototype 3D-BMFs and performing phantom scans on Doheny for MC simulation validation and image quality analysis. Research reported in this paper was supported in part by the National Cancer Institute of the National Institutes of Health under award R01CA181081. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institue of Health.

60 APPLIED LIFE SCIENCES↗