Search NASA⌕ Search

SEARCH · Search NASA

Results for “separation techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Integrating Natural Language Processing and Machine Learning Algorithms to Categorize Oncologic Response in Radiology Reports

A significant volume of medical data remains unstructured. Natural language processing (NLP) and machine learning (ML) techniques have shown to successfully extract insights from radiology reports. However, the codependent effects of NLP and ML in this context have not been well-studied. Between April 1, 2015 and November 1, 2016, 9418 cross-sectional abdomen/pelvis CT and MR examinations containing our internal structured reporting element for cancer were separated into four categories: Progression, Stable Disease, Improvement, or No Cancer. We combined each of three NLP techniques with five ML algorithms to predict the assigned label using the unstructured report text and compared the performance of each combination. The three NLP algorithms included term frequency-inverse document frequency (TF-IDF), term frequency weighting (TF), and 16-bit feature hashing. The ML algorithms included logistic regression (LR), random decision forest (RDF), one-vs-all support vector machine (SVM), one-vs-all Bayes point machine (BPM), and fully connected neural network (NN). The best-performing NLP model consisted of tokenized unigrams and bigrams with TF-IDF. Increasing N-gram length yielded little to no added benefit for most ML algorithms. With all parameters optimized, SVM had the best performance on the test dataset, with 90.6 average accuracy and F score of 0.813. The interplay between ML and NLP algorithms and their effect on interpretation accuracy is complex. The best accuracy is achieved when both algorithms are optimized concurrently.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase stability, ordering tendencies, and magnetism in single-phase fcc Au-Fe nanoalloys

Bulk Au-Fe alloys separate into Au-based fcc and Fe-based bcc phases, but L1 0 and L1 2 orderings were reported in single-phase Au-Fe nanoparticles. Motivated by these observations, we study the structural and ordering energetics in this alloy by combining density functional theory (DFT) calculations with effective Hamiltonian techniques: a cluster expansion with structural filters, and the configuration-dependent lattice deformation model. The phase separation tendency in Au-Fe persists even if the fcc-bcc decomposition is suppressed. The relative stability of disordered bcc and fcc phases observed in nanoparticles is reproduced, but the fully ordered L1 0 AuFe, L1 2 Au 3 Fe, and L1 2 AuFe 3 structures are unstable in DFT. But, a tendency to form concentration waves at the corresponding [001] ordering vector is revealed in nearly-random alloys in a certain range of concentrations. Furthermore, this incipient ordering requires enrichment by Fe relative to the equiatomic composition, which may occur in the core of a nanoparticle due to the segregation of Au to the surface. Effects of magnetism on the chemical ordering are also discussed.

36 MATERIALS SCIENCE↗

Waveguide Calibrator for Multi-Element Probe Calibration

A calibrator, referred to as the spider design, can be used to calibrate probes incorporating multiple acoustic sensing elements. The application is an acoustic energy density probe, although the calibrator can be used for other types of acoustic probes. The calibrator relies on the use of acoustic waveguide technology to produce the same acoustic field at each of the sensing elements. As a result, the sensing elements can be separated from each other, but still calibrated through use of the acoustic waveguides. Standard calibration techniques involve placement of an individual microphone into a small cavity with a known, uniform pressure to perform the calibration. If a cavity is manufactured with sufficient size to insert the energy density probe, it has been found that a uniform pressure field can only be created at very low frequencies, due to the size of the probe. The size of the energy density probe prevents one from having the same pressure at each microphone in a cavity, due to the wave effects. The "spider" design probe is effective in calibrating multiple microphones separated from each other. The spider design ensures that the same wave effects exist for each microphone, each with an indivdual sound path. The calibrator s speaker is mounted at one end of a 14-cm-long and 4.1-cm diameter small plane-wave tube. This length was chosen so that the first evanescent cross mode of the plane-wave tube would be attenuated by about 90 dB, thus leaving just the plane wave at the termination plane of the tube. The tube terminates with a small, acrylic plate with five holes placed symmetrically about the axis of the speaker. Four ports are included for the four microphones on the probe. The fifth port is included for the pre-calibrated reference microphone. The ports in the acrylic plate are in turn connected to the probe sensing elements via flexible PVC tubes. These five tubes are the same length, so the acoustic wave effects are the same in each tube. The flexible nature of the tubes allows them to be positioned so that each tube terminates at one of the microphones of the energy density probe, which is mounted in the acrylic structure, or the calibrated reference microphone. Tests performed verify that the pressure did not vary due to bends in the tubes. The results of these tests indicate that the average sound pressure level in the tubes varied by only 0.03 dB as the tubes were bent to various angles. The current calibrator design is effective up to a frequency of approximately 4.5 kHz. This upper design frequency is largely due to the diameter of the plane-wave tubes.

Sommerfeldt, Scott D.↗

A simple route for making surfactant free lead sulfide (PbS) quantum dots

Highlights: • Surfactant free PbS NCs were successfully synthesised using CoSP technique. • The technique eliminates the requirements of washing to remove the ligands. • Grinding using mortar and pestle creates well separated PbS QDs. • Surfactant free PbS NCs are stable and do not show any degradation with time. - Abstract: An efficient, cost effective and less time consuming method suitable for mass production of surfactant free quantum dots (QDs) of lead sulfide (PbS) is reported. PbS nanocrystals (NCs) are first synthesised by continuous spray pyrolysis (CoSP) technique and de-agglomeration into PbS quantum dots (QDs) is achieved by vigorous mechanical grinding using mortar and pestle. Lead acetate and thiourea were used as the precursor materials for preparation of surfactant free PbS NCs. The broadening in XRD peaks of ground NCs as compared to as synthesized PbS NCs clearly indicated the reduction in particle size to be QDs of PbS. The TEM images also showed that ground PbS NCs were nearly spherical in shape having an average diameter in the range of 4–6 nm. The shift in optical gap from 0.41 eV to 1.47 eV supported the QD formation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bench Scale Thin Film Composite Hollow Fiber Membranes for Post-Combustion Carbon Dioxide Capture

GE Global Research, Idaho National Laboratory (INL), Georgia Institute of Technology (Georgia Tech), and Western Research Institute (WRI) proposed to develop high performance thin film polymer composite hollow fiber membranes and advanced processes for economical post-combustion carbon dioxide (CO 2 ) capture from pulverized coal flue gas at temperatures typical of existing flue gas cleanup processes. The project sought to develop and then optimize new gas separations membrane systems at the bench scale, including tuning the properties of a novel polyphosphazene polymer in a coating solution and fabricating highly engineered porous hollow fiber supports. The project also sought to define the processes needed to coat the fiber support to manufacture composite hollow fiber membranes with high performance, ultra-thin separation layers. Physical, chemical, and mechanical stability of the materials (individual and composite) towards coal flue gas components was considered via exposure and performance tests. Preliminary design, technoeconomic, and economic feasibility analyses were conducted to evaluate the overall performance and impact of the process on the cost of electricity (COE) for a coal-fired plant including capture technologies. At the onset of the project, Membranes based on coupling a novel selective material polyphosphazene with an engineered hollow fiber support was found to have the potential to capture greater than 90% of the CO 2 in flue gas with less than 35% increase in COE, which would achieve the DOE-targeted performance criteria. While lab-scale results for the polyphosphazene materials were very promising, and the material was incorporated into hollow-fiber modules, difficulties were encountered relating to the performance of these membrane systems over time. Performance, as measured by both flux of and selectivity for CO 2 over other flue gas constituents was found to deteriorate over time, suggesting a system that was more dynamic than initially hypothesized. These phenomena are believed to be associated with the physical and mechanical properties of the separation material, rather than chemical degradation by flue gas or one of its constituents. Strategies to improve the composite systems via alternate chemistries and processing techniques were only partially successful in creating a more robust system, but the research provided critical insight into the barriers to engineering sophisticated composite systems for gas separation. Promising concepts, including a re-engineering of the separation material with interpenetrating polymer networks were identified which may prove useful to future efforts in this field.

36 MATERIALS SCIENCE↗

Electrophoresis experiment for space

The Apollo 16 electrophoresis experiment was analyzed, demonstrating that the separation of the two different-size monodisperse latexes did indeed take place, but that the separation was obscured by the pronounced electroosmotic flow of the liquid medium. The results of this experiment, however, were dramatic since it is impossible to carry out a similar separation on earth. It can be stated unequivocally from this experiment that any electrophoretic separation will be enhanced under microgravity conditions. The only question is the degree of this enhancement, which can be expected to vary from one experimental technique to another. The low-electroosmotic-mobility coating (Z6040-MC) developed under this program was found to be suitable for a free-fluid electrophoretic separation such as the experiment designed for the ASTP flight. The problem with this coating, however, is that its permanency is limited because of the slow desorption of the methylcellulose from the coated surface.

Vanderhoff, J. W.↗

Masked-backlighter technique used to simultaneously image x-ray absorption and x-ray emission from an inertial confinement fusion plasma

A method to simultaneously image both the absorption and the self-emission of an imploding inertial confinement fusion plasma has been demonstrated on the OMEGA Laser System. The technique involves the use of a high-Z backlighter, half of which is covered with a low-Z material, and a high-speed x-ray framing camera aligned to capture images backlit by this masked backlighter. Two strips of the four-strip framing camera record images backlit by the high-Z portion of the backlighter, while the other two strips record images aligned with the low-Z portion of the backlighter. The emission from the low-Z material is effectively eliminated by a high-Z filter positioned in front of the framing camera, limiting the detected backlighter emission to that of the principal emission line of the high-Z material. As a result, half of the images are of self-emission from the plasma and the other half are of self-emission plus the backlighter. The advantage of this technique is that the self-emission simultaneous with backlighter absorption is independently measured from a nearby direction. The absorption occurs only in the high-Z backlit frames and is either spatially separated from the emission or the self-emission is suppressed by filtering, or by using a backlighter much brighter than the self-emission, or by subtraction. The masked-backlighter technique has been used on the OMEGA Laser System to simultaneously measure the emission profiles and the absorption profiles of polar-driven implosions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficient use of quantum computers for collider physics

Most observables at particle colliders involve physics at a wide variety of distance scales. Due to asymptotic freedom of the strong interaction, the physics at short distances can be calculated reliably using perturbative techniques, while long distance physics is non-perturbative in nature. Factorization theorems separate the contributions from different scales, allowing to identify the pieces that can be determined perturbatively from those that require non-perturbative information, and if the non-perturbative pieces can be reliably determined, one can use experimental measurements to extract the short distance effects, sensitive to possible new physics. Without the ability to compute the non-perturbative ingredients from first principles one typically identifies observables for which the non-perturbative information is universal in the sense that it can be extracted from some experimental observables and then used to predict other observables. In this paper we argue that the future ability to use quantum computers to calculate non-perturbative matrix elements from first principles will allow to make predictions for observables with non-universal non-perturbative long-distance physics.

Algorithms and Theoretical Developments↗

Diagnostic Ability of Percutaneous Needle Biopsy Immediately After Radiofrequency Ablation for Malignant Lung Tumors: An Initial Experience

PurposeTo evaluate the safety and diagnostic ability of percutaneous needle biopsy performed immediately after lung radiofrequency ablation (RFA).Materials and MethodsFrom May 2013 to April 2014, percutaneous needle biopsy was performed immediately after RFA for 3 patients (2 men and 1 woman, aged 57–76 years) who had lung tumors measuring 1.3–2.6 cm in diameter. All patients had prior history of malignancy, and all tumors were radiologically diagnosed as malignant. Obtained specimens were pathologically classified using standard hematoxylin and eosin staining.ResultsWe completed three planned sessions of RFA followed by percutaneous needle biopsy, all of which obtained tumor tissue that could be pathologically diagnosed. Two tumors were metastatic from renal clear cell carcinoma and rectal adenocarcinoma, respectively; one tumor was primary lung adenocarcinoma. There was no death or major complication related to the procedures. Although pneumothorax occurred in two patients, these resolved without the need for aspiration or chest tube placement. Tumor seeding was not observed, but 21 months after the procedure, one case developed local tumor progression that was treated by additional RFA.ConclusionPathologic diagnosis was possible by needle biopsy immediately after RFA for lung tumors. This technique may reduce the risks and efforts of performing biopsy and RFA on separate occasions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Coincident CdTe Detector Array for Enhanced Nuclear Process Monitoring

Nuclear fuel cycle aqueous separation processes desire improved real-time material characterization and process monitoring techniques; gamma coincidence spectroscopy has the potential to meet this need in these high throughput and high radiation environments based on its ability to reduce background noise, thereby enhancing detection limits and improving isotopic identification accuracy. A detector array composed of three CdTe detectors was designed to surround a chemical processing pipe in a reprocessing facility and evaluate the feasibility of passively assaying the nuclear materials flowing though this measurement point. This array uses commercial off the shelf components that are radiation hard and highly efficiency at low energies relevant to actinide photon signatures. Detector efficiency characterizations, coincidence detection, and potential configuration improvements are presented here.

Good, Erin C.↗

Scanning Seebeck Coefficient Measurement System for Homogeneity Characterization of Bulk and Thin-Film Thermoelectric Materials

Larger-scale production of thermoelectric materials is necessary when mass-producing thermoelectric devices at industrial level. Certain fabrication techniques can create inhomogeneity in the material through composition and doping fluctuations throughout the sample, causing local variations in thermoelectric properties. Some variations are in the range of sub-millimeter scale or larger but may be difficult to detect by traditional materials characterization techniques such as x-ray diffraction or scanning electron microscopy when the chemical variation is small but the doping variation, which strongly affects thermoelectric performance, is large. In this paper, a scanning apparatus to directly detect local variations of Seebeck coefficient on both bulk and thin-film samples is used. Results have shown that this technique can be utilized for detection of defective regions, as well as phase separation in the 100-m range or larger.

Iwanaga, S↗

Synchrotron based mass spectrometry to investigate the molecular properties of mineral-organic associations

Soil organic matter (OM) is important because its decay drives life processes in the biosphere. Analysis of organic compounds in geological systems is difficult because of their intimate association with mineral surfaces. To date there is no procedure capable of quantitatively separating organic from mineral phases without creating artifacts or mass loss. Therefore, analytical techniques that can (a) generate information about both organic and mineral phases simultaneously and (b) allow the examination of predetermined high-interest regions of the sample as opposed to conventional bulk analytical techniques are valuable. Laser Desorption Synchrotron Postionization (synchrotron-LDPI) mass spectrometry is introduced as a novel analytical tool to characterize the molecular properties of organic compounds in mineral-organic samples from terrestrial systems, and it is demonstrated that when combined with Secondary Ion Mass Spectrometry (SIMS), can provide complementary information on mineral composition. Mass spectrometry along a decomposition gradient in density fractions, verifies the consistency of our results with bulk analytical techniques. We further demonstrate that by changing laser and photoionization energies, variations in molecular stability of organic compounds associated with mineral surfaces can be determined. The combination of synchrotron-LDPI and SIMS shows that the energetic conditions involved in desorption and ionization of organic matter may be a greater determinant of mass spectral signatures than the inherent molecular structure of the organic compounds investigated. The latter has implications for molecular models of natural organic matter that are based on mass spectrometric information.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solid-State NMR Investigations of Carbon Dioxide Gas in Metal–Organic Frameworks: Insights into Molecular Motion and Adsorptive Behavior

Solid-state nuclear magnetic resonance (SSNMR) methods have been routinely used for the characterization of both the structure and the dynamics of metal organic frameworks (MOFs), a collection of porous media investigated for potential applications in carbon capture technologies, selective separation of small molecules, and catalysis.(1) The use and development of SSNMR techniques that enable the nondestructive characterization of the adsorbed behavior have become essential steps in bettering our understanding of MOFs and are often complementary to traditional methods of structural characterization. This Review aims to give a brief introduction to the relevant concepts of SSNMR and the methods employed when investigating the phenomenon of adsorbed carbon dioxide gas in MOFs. We summarize the published SSNMR literature on CO2 in MOFs, as well as highlight the best experimental practices when working with these complex systems.

membrane, carbon capture, materials and chemistry ↗

Influence of Nd(II) and Nd(III) Ions on the Speciation and Kinetic Dynamics of Radiolytic Transients in Molten LiCl-KCl Eutectic Salt Mixtures

In the pyrochemical reprocessing of used nuclear fuel, understanding the effects of ionizing radiation on the chemical behavior of fission products in molten chloride eutectic salt is crucial. Here, this study investigates the impact of radiation on the chemical and kinetic speciation of Nd ions in molten LiCl-KCl eutectic, which are challenging to separate due to their multivalent oxidation states and comproportionation reactions. Electron pulse radiolysis techniques were used to determine transient absorption spectra, chemical kinetics, and activation parameters for the reaction of Nd ions with the primary products of molten LiCl-KCl eutectic radiolysis: the solvated electron (e S - ) and dichlorine radical anion (Cl 2 •- ). Initially, Nd(III) reacted rapidly with e S - , forming Nd(II) with a second-order rate coefficient of k = (4.54 ± 0.07) × 10 10 M -1 s -1 at 673 K. The resulting Nd(II) ions then reacted slowly with Cl 2 •- , regenerating Nd(III) with an estimated rate of k = (1.72 ± 0.04) × 10 10 M -1 s -1 at 673 K. Additionally, the comproportionation reaction of Nd(III) and Nd(s) to form Nd(II) was monitored chemically and electrochemically. This work suggests that the comproportionation reaction of Nd(III) with Nd(s) to form Nd(II) is unstable in molten LiCl-KCl eutectic.

36 - MATERIALS SCIENCE↗

Toward Rapid Actinium-225 Purification via Membrane Adsorbers with Covalently Tethered Diglycolamide Ligands

Extractive diglycolamide (DGA) resins are used in several state-of-the-art techniques for purifying 225 Ac, a promising radiometal for targeted alpha therapy. Unfortunately, separation processes that rely on resins are often limited to slow flow rates, high elution volumes, and long processing times. Membrane adsorbers functionalized with DGA ligands are an alternative separation material that may overcome these challenges. This work presents (1) the synthesis of an aminated tetrahexyldiglycolamide ligand, (2) the covalent tethering of the ligand to electrospun poly(vinylbenzyl chloride) fiber mats, and (3) the adsorption and desorption of La(III) and 225 Ac. Chemical and physical characterization supports the covalent tethering of the ligand to the fiber mat, as well as the preservation of the fiber surface area and porosity after functionalization. Equilibrium adsorption experiments were performed with stable La(III) and radioactive 225 Ac. Trends in affinity are consistent between commercial resins and the synthesized membrane adsorbers; however, the Langmuir constants and the maximum binding capacity of the membrane adsorbers were generally lower than the resins. Despite these differences, the modeled selectivity for an equimolar solution of La(III)/ 225 Ac in 10 M nitric acid is 57. Furthermore, 225 Ac is rapidly desorbed from the fibers in 10 M nitric acid (<20 min). The La(III)/ 225 Ac selectivity and rapid 225 Ac desorption indicate this class of materials is promising for rapid radioanalytical separations.

07 ISOTOPE AND RADIATION SOURCES↗

Electrochemical Control of Ion Transport through a Mesoporous Carbon Membrane

The transport of fluids through nanometer scale channels typically on the order of 1 -100 nm often exhibit unique properties compared to the bulk fluid. These phenomena occur because the channel dimensions and molecular size become comparable to the range of several important forces including electrostatic and van der Waals forces. Small changes in properties such as the electric double layer or surface charge can significantly affect molecular transport through the channels. Based on these emerging properties, a variety of nanofluidic devices such as nanofluidic transistors, nanofluidic diodes or lab-on-a-chip devices have been developed with a diverse range of applications including water purification, biomolecular sensing, DNA separation, and rectified ion transport. Nanofluidic devices are typically fabricated using expensive lithography techniques or sacrificial templates. Here in this paper we report a carbon-based, three-dimensional nanofluidic transport membrane that enables gated, or on/off, control of the transport of organic molecular species and metal ions using an applied electrical potential. Finally, in the absence of an applied potential, both cationic and anionic molecules freely diffuse across the membrane via a concentration gradient. However, when an electrochemical potential is applied, the transport of ions through the membrane is inhibited.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low temperature hydrogenation of pyrolytic lignin over Ru/TiO 2 : 2D HSQC and 13 C NMR study of reactants and products

In this paper, pyrolytic lignin and hydrogenated pyrolytic lignin were characterized by 2D 1 H– 13 C HSQC and quantitative 13 C NMR techniques. The pyrolytic lignin was produced from a mixed maple wood feedstock and separated from the bio-oil by water extraction. p-Hydroxyphenyl (H), guaiacyl (G), and syringyl (S) aromatics were the basic units of pyrolytic lignin. The native lignin β-aryl ether, phenylcoumaran and resinol structures were not present in the pyrolytic lignin. The hydrogenation was conducted with a Ru/TiO 2 catalyst at temperatures ranging from 25–150 °C with higher temperatures exhibiting higher levels of hydrogenation. Solid coke formed on the catalyst surface (1% coke yield) even for hydrogenation at 25 °C. The carbon yield of pyrolytic lignin to coke increased from 1% to 5% as the hydrogenation temperature increased from 25 to 150 °C. A single-step hydrogenation at 150 °C resulted in a reduction from 65% to 39% aromatic carbons. A three-step hydrogenation scheme at this same temperature resulted in a reduction of aromatic carbons from 65% to 17%. The decrease in the aromatic carbon corresponded with an increase in the aliphatic carbon. Coke formation reduced from a 5% carbon yield of pyrolytic lignin in the first hydrogenation step to a 1% carbon yield in each of the second and third hydrogenation steps. The pyrolytic lignin could be separated into a high and low molecular weight fraction. Finally, the coke yield from the high molecular weight fraction was twice as much as that from the low molecular weight fraction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct analysis of cotton swipes for plutonium isotope determination by microextraction-ICP-MS

This study demonstrates a method for determining the isotopic composition of low-level (sub-pg) plutonium (Pu) directly from a cotton swipe. Environmental sample (ES) swipes are routinely employed as a tool for monitoring activities in nuclear facilities. Traditional ES swipe analysis, as employed in nuclear safeguards, utilizes laborious ashing, digestion, and chemical separation procedures prior to mass spectrometric (MS) analysis. Here, an innovative sample introduction technique employing a microextraction probe to extract Pu directly from the swipe surface is described. The microextraction probe lowers onto the swipe surface, seals on a small area (8 mm 2 ), and delivers solvent (2% HNO 3 ) to extract actinide material that may be present. The extracted analyte is subsequently directed into a sector field inductively coupled plasma (ICP)-MS for isotope ratio determination. This microextraction-ICP-MS method successfully determined the isotopic composition ( 240 Pu/ 239 Pu and 242 Pu/ 239 Pu) of three Pu certified reference materials (CRM 136, 137, and 138) that were deposited (1 pg) onto ES swipes. The percent relative difference from the certified value, uncorrected for instrumental fractionation, was <2% for the 240 Pu/ 239 Pu ratio on all three CRMs and <10% for the 242 Pu/ 239 Pu ratio on CRM 136 and 138. Here, the percent relative standard deviation, an estimate of the sample-to-sample isotopic precision, was <4% for the 240 Pu/ 239 Pu and <15% for the 242 Pu/ 239 Pu. Method limits of detection were determined, based on measurements of an enriched 244 Pu material, to be ~7 fg. Additionally, a mixed uranium (U) and Pu deposition was made to determine the method's ability to simultaneously extract U and Pu and determine the isotopic composition of both analytes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗