Search NASA⌕ Search

SEARCH · Search NASA

Results for “source characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Multi-client quantum key distribution using wavelength division multiplexing

Quantum Key Distribution (QKD) exploits the rules of quantum mechanics to generate and securely distribute a random sequence of bits to two spatially separated clients. Typically a QKD system can support only a single pair of clients at a time, and so a separate quantum link is required for every pair of users. We overcome this limitation with the design and characterization of a multi-client entangled-photon QKD system with the capacity for up to 100 clients simultaneously. The time-bin entangled QKD system includes a broadband down-conversion source with two unique features that enable the multi-user capability. First, the photons are emitted across a very large portion of the telecom spectrum. Second, and more importantly, the photons are strongly correlated in their energy degree of freedom. Using standard wavelength division multiplexing (WDM) hardware, the photons can be routed to different parties on a quantum communication network, while the strong spectral correlations ensure that each client is linked only to the client receiving the conjugate wavelength. In this way, a single down-conversion source can support dozens of channels simultaneously--and to the extent that the WDM hardware can send different spectral channels to different clients, the system can support multiple client pairings. We will describe the design and characterization of the down-conversion source, as well as the client stations, which must be tunable across the emission spectrum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Portrait and Classification of Individual Haze Particulates

Haze (known as “Mai” in Chinese) threatens the health of billions of people across the globe. To begin solving this problem without severely slowing down the economy, one has to mechanistically and geographically pinpoint the sources of these pollutants, the key of which is to thoroughly characterize and fingerprint the particulates. Here we present a broad survey and classification of thousands of individual airborne particu-lates by using the Scanning Electron Microscope (SEM) to measure their diverse mor-phologies and chemistries, which could eventually be organized into a “haze finger-print database”. For instance, one collection in Xi’an City, China during March-April 2014 yielded 494 airborne particulates that settled on silicon wafers placed outside the window of a 3rd floor office. These 494 particulates were manually imaged with high resolution (down to 2 nm), elementally mapped using Energy-dispersive X-ray Spec-troscopy (EDS), and were identified and categorized into presumed source classes such as construction activities (Ca, Al, Si-O), coal burning (sulfates), biologic (pollen, bac-teria), automotive, mining, steel making, and etc. About 20% of the particulates have mysterious origins, as it is still unclear how they were formed, and a fraction of them contained clearly hazardous elements such as lead and chromium. For future work, we propose using unmanned aerial vehicles with a special “rolling film” substrate that can autonomously collect airborne particulates, a customized SEM auto-imaging system, and machine learning software to establish an online open-access database. The end goal would be to monitor and analyze the particulate pollutants that are pumped into our atmosphere every day, and precisely track down their sources so we can better model and police the quality of the air around us.

54 ENVIRONMENTAL SCIENCES↗

Measurements of source emittance and beam coherence properties of the upgraded Advanced Photon Source

The Advanced Photon Source (APS) has been upgraded with a multi-bend achromat lattice, achieving significantly reduced electron beam emittance and enhanced X-ray coherence. Precise characterization of these properties is essential for optimizing beamline performance and enabling new experiments that take full advantage of the upgraded source. We report on measurements of source size and transverse coherence properties using grating interferometry at two beamlines: the APS 3-ID-B undulator beamline and the 1-BM-B bending magnet beamline. The results confirm the world-record horizontal emittance of the upgraded APS below 30 pm rad and validate the theoretical design parameters. We further investigate the impact of optical aberrations and mechanical vibrations at the 12-ID-C beamline on coherence preservation. These measurements establish a benchmark for future beamline enhancements and demonstrate the effectiveness of grating interferometry for high-precision beam characterization. Our findings provide critical insights into synchrotron beam dynamics, coherence degradation mechanisms, and strategies for optimizing beamline X-ray optics at next-generation light sources.

Advanced Photon Source↗

Sources of deactivation during glycerol conversion on Ni/γ-Al 2 O 3

Hydrogenolysis of glycerol was studied using a diluted aqueous solution of glycerol in gas phase and atmospheric pressure on Ni/γ-Al2O3 catalyst. The catalytic transformation of glycerol generates products derived from dehydration, dehydrogenation, hydrogenolysis and condensation reactions. Deep hydrogenolysis route to produce CH4 prevails in the first few hours of reaction. As the reaction time progress, dehydration-dehydrogenation products start to appear. Here, a description of the deactivation sources and its effects on the catalytic performance of Ni catalyst was proposed. The catalyst was characterized before and after the catalytic reaction by high-resolution transmission electron microscopy (HRTEM) and by employing Fourier transformed infrared spectroscopy (FTIR) of adsorbed CO. A source of deactivation was due to carbonaceous deposition. FTIR at low CO dosing pressure reveal bands assignments species essentially due to linear and bridge carbonyls, whereas high pressure CO dosing produces a complex spectra due to polycarbonyls. X-ray absorption near edge structure (XANES) analysis was employed to reveal the initial degree of reduction of the fresh catalyst. The oxidation of metallic Ni in the course of reaction may also be considered as a source of deactivation. Ni oxide species promote dehydration routes. Alumina support facilitates nickel species to be more active toward interacting with glycerol. Dehydration, which takes place on the acid sites, is the mainly route related to the generation of carbon deposition and to the observed catalyst deactivation. Another source of deactivation was due to carbiding of Ni to form Ni3C. The regeneration of used Ni catalyst was achieved by oxidation-reduction steps at 723 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Selected advances in small-angle scattering and applications they serve in manufacturing, energy and climate change

Innovations in small-angle X-ray and neutron scattering (SAXS and SANS) at major X-ray and neutron facilities offer new characterization tools for researching materials phenomena relevant to advanced applications. For SAXS, the new generation of diffraction-limited storage rings, incorporating multi-bend achromat concepts, dramatically decrease electron beam emittance and significantly increase X-ray brilliance over previous third-generation sources. This results in intense X-ray incident beams that are more compact in the horizontal plane, allowing significantly improved spatial resolution, better time resolution, and a new era for coherent-beam SAXS methods such as X-ray photon correlation spectroscopy. Elsewhere, X-ray free-electron laser sources provide extremely bright, fully coherent, X-ray pulses of <100 fs and can support SAXS studies of material processes where entire SAXS data sets are collected in a single pulse train. Meanwhile, SANS at both steady-state reactor and pulsed spallation neutron sources has significantly evolved. Developments in neutron optics and multiple detector carriages now enable data collection in a few minutes for materials characterization over nanometre-to-micrometre scale ranges, opening up real-time studies of multi-scale materials phenomena. SANS at pulsed neutron sources is becoming more integrated with neutron diffraction methods for simultaneous structure characterization of complex materials. In this paper, selected developments are highlighted and some recent state-of-the-art studies discussed, relevant to hard matter applications in advanced manufacturing, energy and climate change.

36 MATERIALS SCIENCE↗

Benefits of utilizing CellProfiler as a characterization tool for U–10Mo nuclear fuel

Automated image processing techniques have the potential to aid in the performance evaluation of nuclear fuels by eliminating judgment calls that may vary from person-to-person or sample-to-sample. Analysis of in-core fuel performance is required for design and safety evaluations related to almost every aspect of the nuclear fuel cycle. This study presents a methodology for assessing the quality of uranium–molybdenum fuel images and describes image analysis routines designed for the characterization of several important microstructural properties. The analyses are performed in CellProfiler, an open-source program designed to enable biologists without training in computer vision or programming to automatically extract cellular measurements from large image sets. The quality metric scores an image based on three parameters: the illumination gradient across the image, the overall focus of the image, and the fraction of the image that contains scratches. The metric presents the user with the ability to ‘pass’ or ‘fail’ an image based on a reproducible quality score. Passable images may then be characterized through a separate CellProfiler pipeline, which enlists a variety of common image analysis techniques. The results demonstrate the ability to reliably pass or fail images based on the illumination, focus, and scratch fraction of the image, followed by automatic extraction of morphological data with respect to fission gas voids, interaction layers, and grain boundaries. - Graphical abstract: Display Omitted - Highlights: • A technique is developed to score U–10Mo FIB-SEM image quality using CellProfiler. • The pass/fail metric is based on image illumination, focus, and area scratched. • Automated image analysis is performed in pipeline fashion to characterize images. • Fission gas void, interaction layer, and grain boundary coverage data is extracted. • Preliminary characterization results demonstrate consistency of the algorithm.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Improving Characterization of Miscellaneous Energy Loads in Energy Demand Models

Miscellaneous energy loads (MELs) comprise a significant and growing portion of total building energy consumption. However relatively little is known about the products that make up MELs end uses, and MELs are modeled with less granularity than major end uses in energy demand models such as the U.S. Department of Energy’s Scout energy efficiency impact analysis tool or the U.S. Energy Information Administration’s National Energy Modeling System (NEMS). This paper identifies differences in the way MELs versus major building end uses are modeled, and then reviews potential sources of MELs baseline technology data that could be used to improve their characterization in energy demand models. Case studies of dry distribution transformers, hot water circulation pumps, and Japanese-style automatic bidets are presented to compare and contrast the level of baseline data available for different end uses. We show that there is potential to use data from energy conservation standards and other sources to significantly improve representation of some MELs in energy demand models, while other emerging MELs require further data collection before they can be modeled precisely.

Miscellaneous Electric Loads, MELs, Models, Nation↗

Proton emission from a laser ion source

At intensities of the order of 10{sup 10} W/cm{sup 2}, ns pulsed lasers can be employed to ablate solid bulk targets in order to produce high emission of ions at different charge state and kinetic energy. A special interest is devoted to the production of protons with controllable energy and current from a roto-translating target irradiated in repetition rate at 1-10 Hz by a Nd:Yag pulsed laser beam. Different hydrogenated targets based on polymers and hydrates were irradiated in high vacuum. Special nanostrucutres can be embedded in the polymers in order to modify the laser absorption properties and the amount of protons to be accelerated in the plasma. For example, carbon nanotubes may increase the laser absorption and the hydrogen absorption to generate high proton yields from the plasma. Metallic nanostrucutres may increase the electron density of the plasma and the kinetic energy of the accelerated protons. Ion collectors, ion energy analyzer, and mass spectrometers, used in time-of-flight configuration, were employed to characterize the ion beam properties. A comparison with traditional proton ion source is presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Understanding the Fluorination of Disordered Rocksalt Cathodes through Rational Exploration of Synthesis Pathways

Here, we have designed and tested several synthesis routes targeting a highly fluorinated disordered rocksalt (DRX) cathode, Li 1.2 Mn 0.4 Ti 0.4 O 1.6 F 0.4 , with each route rationalized by thermochemical analysis. Precursor combinations were screened to raise the F chemical potential and avoid the formation of LiF, which inhibits fluorination of the targeted DRX phase. MnF 2 was used as a reactive source of F, and Li 6 MnO 4 , LiMnO 2 , and Li 2 Mn 0.33 Ti 0.66 O 3 were tested as alternative Li sources. Each synthesis procedure was monitored using a multi-modal suite of characterization techniques including X-ray diffraction, nuclear magnetic resonance, thermogravimetric analysis, and differential scanning calorimetry. From the resulting data, we advance the understanding of oxyfluoride synthesis by outlining the key factors limiting F solubility. At low temperatures, MnF 2 consistently reacts with the Li source to form LiF as an intermediate phase, thereby trapping F in strong Li-F bonds. LiF can react with Li 2 TiO 3 to form a highly lithiated and fluorinated DRX (Li 3 TiO 3 F); however, MnO is not easily incorporated into this DRX phase. Although higher temperatures typically increase solubility, the volatility of LiF above its melting point (848 °C) inhibits fluorination of the DRX phase. Based on these findings, metastable synthesis techniques are suggested for future work on DRX fluorination.

36 MATERIALS SCIENCE↗

Source detection at 100 meter standoff with a time-encoded imaging system

Here, we present the design, characterization, and testing of a laboratory prototype radiological search and localization system. The system, based on time-encoded imaging, uses the attenuation signature of neutrons in time, induced by the geometrical layout and motion of the system. We have demonstrated the ability to detect a ~1 mCi 252 Cf radiological source at 100 m standoff with 90% detection efficiency and 10% false positives against background in 12 min. As a result, this same detection efficiency is met at 15 s for a 40 m standoff, and 1.2 s for a 20 m standoff.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Open Source Visualization and Analysis Platform for 3D Reconstructions of Materials by Transmission Electron Microscopy

Three-dimensional characterization of materials at the nano- and meso-scale has become possible with transmission and scanning transmission electron microscopes (S/TEM). Its importance has extended to a wide class of nanomaterials such as hydrogen fuel cells, solar cells, industrial catalysts, new battery materials and semiconductor devices, as well as spanning high-tech industry, universities, and national labs. While capable instrumentation is abundant, this rapidly expanding demand for high-resolution tomography is bottlenecked by software that is instead tailored for lower-dose, biological applications and not optimized for higher-resolution materials applications. Existing tomography fails to utilize the chemical information provided by S/TEM spectrometers. To address this problem, this project delivered a scalable, fully functional, freely-distributable, open Source materials tomography package with a modern user interface that enables automated acquisition, alignment, and real-time reconstruction of raw tomography data, and provides advanced segmentation, three-dimensional chemical visualization and analysis optimized for materials applications. It has established an extendable framework capable of automation for high-throughput for the tomography of materials from data acquisition to visualization. Phase I and II delivered a full-featured, cross-platform, clean and integrated application for S/TEM materials tomography. It can read projection data from the microscope, with graphical tools for alignment of data, tomographic reconstruction, segmentation, and visualization of the reconstructed 3D volume. The entire pipeline can be saved to an XML state file, enabling fully reproducible data processing and analysis with a full Python environment for the development of custom algorithms, processing, and analysis requirements. Phase IIB extended the application to provide real-time tomographic reconstruction, "live updates" as data is processed, analysis of big data, and multi-channel tomography. Here, quantitative assessment of nanomaterials can occur as data is being recorded on a 3D visualization platform that accommodates additional information from multiple channels. We provide unmatched high-throughput tomography, where the complete tomographic pipeline from measurement to 3D visualization can occur rapidly. The project was extended to offer capabilities for micro-CT, X-ray, neutron, focused ion beam, atomic electron tomography and atom probe tomography. With over 600 transmission electron microscopes worldwide and approximately 50 coming online each year, the demand and impact of an open-source tomography tool is large. Significant opportunities exist in high-tech industry, universities, and national labs to enable or enhance three-dimensional imaging at the nanoscale and bring automated high-throughput approaches that will accelerate progress in materials characterization and metrology. The project supports a service based business model by enabling lab-specific acquisition and processing customization and integration-support and development that will be provided into Phase III and beyond.

36 MATERIALS SCIENCE↗

TRACING THE REVERBERATION LAG IN THE HARD STATE OF BLACK HOLE X-RAY BINARIES

We report results obtained from a systematic analysis of X-ray lags in a sample of black hole X-ray binaries, with the aim of assessing the presence of reverberation lags and studying their evolution during outburst. We used XMM-Newton and simultaneous Rossi X-ray Timing Explorer (RXTE) observations to obtain broadband energy coverage of both the disk and the hard X-ray Comptonization components. In most cases the detection of reverberation lags is hampered by low levels of variability-power signal-to-noise ratio (typically when the source is in a soft state) and/or short exposure times. The most detailed study was possible for GX 339-4 in the hard state, which allowed us to characterize the evolution of X-ray lags as a function of luminosity in a single source. Over all the sampled frequencies (∼0.05–9 Hz), we observe the hard lags intrinsic to the power-law component, already well known from previous RXTE studies. The XMM-Newton soft X-ray response allows us to detail the disk variability. At low frequencies (long timescales) the disk component always leads the power-law component. On the other hand, a soft reverberation lag (ascribable to thermal reprocessing) is always detected at high frequencies (short timescales). The intrinsic amplitude of the reverberation lag decreases as the source luminosity and the disk fraction increase. This suggests that the distance between the X-ray source and the region of the optically thick disk where reprocessing occurs gradually decreases as GX 339-4 rises in luminosity through the hard state, possibly as a consequence of reduced disk truncation.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantifying uncertainty in uranium concentration measurements via K-edge densitometry

This study quantifies the uncertainty in uranium concentration predictions of fluoride and chloride-based salts within a steel pipe using K-edge densitometry. Modeling and simulation was conducted with the Monte Carlo N-Particle Transport (MCNP) code. The quality of of this technique’s prediction in a pipe requires proper characterization of the pipe’s thickness, which is dependent on the source size and axial offset from the pipe centerline. The thickness was determined as either the center-line thickness seen by the X-ray source or an average value determined through random sampling. Generally, the predicted concentrations were slightly better at lower offset with the random sampling thickness and using the center-line thickness for the highest offsets. For a line-beam source and varying axial offsets, the relative error of concentration was within 1% of the true value but uncertainty increased by 2 orders of magnitude. Similarly, for no axial offset, the relative error was significantly less than 1% while no trend for uncertainty was found. However, at the largest possible offset for a given source size, the concentrations become erroneous and greater than the allowable 1% relative error. Furthermore, high offsets tended to increase the variance of the transmission spectra by 3 orders of magnitude.

Characterization and Analytical Technique↗

A Synchrotron-Based Facility for the in-situ Location, Chemical and Mineralogical Characterization of ~10 um Particles Captured in Aerogel

NASA's Stardust mission collected dust from the coma of Comet Wild-2 on January 2nd, 2004, by direct capture into aerogel cells that flew through the dust coma at 6 km/s. Stardust collected several hundred comet particles >10 {mu}m in size. These comet samples were delivered to Earth on January 15th, 2006. We developed a facility at the National Synchrotron Light Source at Brookhaven National Laboratory (Upton, NY, USA) for the in-situ characterization of 10 {mu}m particles collected in aerogel. These analytical instruments allow us to perform extensive chemical, mineralogical, and size-frequency characterization of particles captured in aerogel. These analyses are conducted without any invasive extraction, minimizing the possibility of contamination or particle loss during preparation. This facility was used to determine the chemical composition, the oxidation state, the mineralogy and to provide an indication of the grain size of the Wild-2 particles before they were removed from the aerogel. This information provides a catalog of particle types, allowing a more reasoned allocation of the particles to subsequent investigators based on a relatively detailed knowledge of the chemical composition and mineralogy of each particle. These measurements allowed a comparison of the chemical and mineralogical properties of the Wild-2 particles with other types of extraterrestrial materials, including interplanetary dust particles and meteorites. The success of in-situ analysis for Wild 2 particles demonstrates that synchrotron-based facilities will be important for the analysis of particles collected in aerogel on future earth-orbiting satellites and spacecraft.

43 PARTICLE ACCELERATORS↗

Commissioning of a Varian Clinac iX 6 MV photon beam using Monte Carlo simulation

Monte Carlo modelling of a linear accelerator is the first and most important step in Monte Carlo dose calculations in radiotherapy. Monte Carlo is considered today to be the most accurate and detailed calculation method in different fields of medical physics. In this research, we developed a photon beam model for Varian Clinac iX 6 MV equipped with MilleniumMLC120 for dose calculation purposes using BEAMnrc/DOSXYZnrc Monte Carlo system based on the underlying EGSnrc particle transport code. Monte Carlo simulation for this commissioning head LINAC divided in two stages are design head Linac model using BEAMnrc, characterize this model using BEAMDP and analyze the difference between simulation and measurement data using DOSXYZnrc. In the first step, to reduce simulation time, a virtual treatment head LINAC was built in two parts (patient-dependent component and patient-independent component). The incident electron energy varied 6.1 MeV, 6.2 MeV and 6.3 MeV, 6.4 MeV, and 6.6 MeV and the FWHM (full width at half maximum) of source is 1 mm. Phase-space file from the virtual model characterized using BEAMDP. The results of MC calculations using DOSXYZnrc in water phantom are percent depth doses (PDDs) and beam profiles at depths 10 cm were compared with measurements. This process has been completed if the dose difference of measured and calculated relative depth-dose data along the central-axis and dose profile at depths 10 cm is ≤ 5%. The effect of beam width on percentage depth doses and beam profiles was studied. Results of the virtual model were in close agreement with measurements in incident energy electron 6.4 MeV. Our results showed that photon beam width could be tuned using large field beam profile at the depth of maximum dose. The Monte Carlo model developed in this study accurately represents the Varian Clinac iX with millennium MLC 120 leaf and can be used for reliable patient dose calculations. In this commissioning process, the good criteria of dose difference in PDD and dose profiles were achieve using incident electron energy 6.4 MeV.

61 RADIATION PROTECTION AND DOSIMETRY↗

Mesoscale Numerical Characterization of Kevlar and Carbon–Kevlar Hybrid Plain-Woven Fabric Compression Behavior

A mesoscale finite element model (FEM) of the plain-woven fabric representative elementary volume (REV/unit cell) is developed. The developed FEM is used to predict the nonlinear compaction behavior of monolithic and intraply hybrid fabric made of high-strength carbon and Kevlar fibers. For geometrical modeling of the fabric REV, TexGen, an open-source geometrical modeling software (developed at Nottingham University), is utilized, and for mechanical characterization, FE simulation tool Abaqus{sup ®} is used. Geometrical nonlinearity of the fabric, including periodic boundary conditions and yarn interactions, is incorporated in the REV FE model. Material nonlinearity caused by transversely isotropic behavior of fibrous yarns is implemented through the user material subroutine form in FE simulation along with local orientation assigned to each yarn in the REV. Material properties of fibers are extracted from the literature and supplier data. The compression behavior of monolithic Kevlar and hybrid carbon–Kevlar (carbon warp and Kevlar weft yarns, C–K) fabric is predicted using the proposed FE model. FEM-predicted results were found to have good agreement with the experimentally obtained ones. Results depict that C–K hybrid fabrics have improved compression strength. Hybridization effect is governed by yarns mutual interaction, yarn area at crossovers, and transverse in-plane properties of the interyarn hybridized fabric. The proposed FE model can be used to predict the mechanical behavior of woven fabrics with different weaving patterns, unit cell geometry, material properties, and loading conditions.

36 MATERIALS SCIENCE↗

Mercury concentrations in urine of amerindian populations near oil fields in the peruvian and ecuadorian amazon

Background: Mercury is a global contaminant with toxic, persistent effects on human health. Petroleum extraction is an important source of elemental mercury; little is known about human exposure levels near oil fields in the Amazon basin. Objectives: To characterize mercury levels in people living near oil production sites in the Peruvian and Ecuadorian Amazon, controlling for fish consumption, occupation, source of water and socio-demographic characteristics. Methods: Analyze mercury levels in urine samples using cold vapour atomic fluorescence spectrometry from 76 indigenous men and women in eight riverine communities situated near oil wells or pipelines. Subjects answered a questionnaire soliciting socio-demographic, occupational and dietary information. Data were analyzed using multiple linear regression modeling. Results: The mean value of U-Hg was 2.61 μg/g creatinine (95% CI: 2.14–3.08), with 7% of the sample recording values above the global background standard suggested by The World Health Organization (5 μg/g creatinine). Women who used water from a surface source had two and a half times the amount of mercury in their urine (mean=3.70 μg/g creatinine, 95% CI: 2.26–5.15) compared with women who used other water sources (mean =1.39 μg/g creatinine, 95% CI: 0.51–2.25). Men who were involved in an oil clean-up operation had twice as much mercury in their urine (mean =3.07 μg/g creatinine, 95% CI: 1.97–4.16) as did those who worked on other tasks (mean =1.56 μg/g creatinine, 95% CI: 1.48–2.65). Mercury levels were not associated with the number of fish meals per week. Conclusions: Indigenous peoples of the Peruvian and Ecuadorian Amazon living near oil production sites generally had urine mercury levels within the global background standard suggested by the World Health Organization. Increased levels of mercury in urine were detected for men involved in oil spill remediation and for women who relied on surface water for household needs. These findings signal the need for strict safety measures to limit the amount of oil entering the waterways in Andean Amazonia so as to protect the health of indigenous people. - Highlights: • 7% of participants had levels of inorganic mercury at or exceeding levels suggested by WHO (5 μg/g creatinine). • U-Hg levels were 2.5 times higher among women using surface water than those who drew on water from a well, spring or rain. • Men who had worked cleaning up an oil spill had more than twice the amount of mercury in their urine as men who did not.

54 ENVIRONMENTAL SCIENCES↗

Study of keV radiation properties of Mo and Ti X-pinch plasma sources using a pinhole transmission grating spectrometer

The properties of keV x-ray radiations from Mo and Ti X-pinch plasma sources at the current of 800 kA were investigated by a pinhole transmission grating spectrometer. The spectrometer was characterized by a high linear dispersion rate (2.9 A/mm), and from its time-integrated diffraction images, rich information about the X-pinch sources (e.g., source number, source size, and absolute spectra) could be obtained. Multiple hot spots were produced in all the Mo tests with loads made of two or four 25 mum wires with or without a shunt wire, and obvious increases both in the radiation intensity and in the source size around the spectral region of 2.6 keV were observed. In Ti X-pinch tests, a single keV x-ray burst with a source size of approx200 mum and a time duration of approx200 ps in full width at half maximum was obtained using a load made of two 50 mum wires plus a shunt wire. The intensity of x-rays decreased sharply from approx10{sup 11} photon eV{sup -1} sr{sup -1} at 1 keV to approx10{sup 8} photon eV{sup -1} sr{sup -1} at 4 keV. The energy-dependent source size in the band of 1-4 keV is less than 100 mum and seemed to shrink quickly as x-ray energy increases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗