Search NASA⌕ Search

SEARCH · Search NASA

Results for “statistical comparison”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

A General Framework to Learn Tertiary Structure for Protein Sequence Characterization

During the past five years, deep-learning algorithms have enabled ground-breaking progress towards the prediction of tertiary structure from a protein sequence. Very recently, we developed SAdLSA, a new computational algorithm for protein sequence comparison via deep-learning of protein structural alignments. SAdLSA shows significant improvement over established sequence alignment methods. In this contribution, we show that SAdLSA provides a general machine-learning framework for structurally characterizing protein sequences. By aligning a protein sequence against itself, SAdLSA generates a fold distogram for the input sequence, including challenging cases whose structural folds were not present in the training set. About 70% of the predicted distograms are statistically significant. Although at present the accuracy of the intra-sequence distogram predicted by SAdLSA self-alignment is not as good as deep-learning algorithms specifically trained for distogram prediction, it is remarkable that the prediction of single protein structures is encoded by an algorithm that learns ensembles of pairwise structural comparisons, without being explicitly trained to recognize individual structural folds. As such, SAdLSA can not only predict protein folds for individual sequences, but also detects subtle, yet significant, structural relationships between multiple protein sequences using the same deep-learning neural network. The former reduces to a special case in this general framework for protein sequence annotation.

59 BASIC BIOLOGICAL SCIENCES↗

Integration of ‘omics technologies for characterization of complex microbial ecosystems - 8119

Environmental remediation sites possess complexity at both biotic and abiotic levels, with temporal shifts that are associated with the interaction of both systems. Single scientific disciplines no longer serve to address and understand the complex nature of these sites. An integration of physical, chemical, and biological characterizations or a more inclusive environmental systems approach is needed. As a proof of concept, an integrated approach was developed to identify biosignatures from a complex environmental community to provide sensitive, early indicators and predictors of response to radionuclide and chemical exposures of interest for environmental management. Specifically, the integrated approach used a combination of genetics, transcriptomics, proteomics, and computational statistics to characterize a complex periphyton community following uranium exposure. This additional, specific information has promise to further reduce uncertainties in environmental remediation and monitoring in realizing the potential impacts of exposure in advance to reduce potential mitigation efforts. Results from this study establish a basis for biosignature characterization of any ecosystem for comparison or monitoring of biotic exposure and effects in response to a specific contaminant.

59 BASIC BIOLOGICAL SCIENCES↗

Comparison of Methods to Determine Tropical Tropopause Layer Cirrus Formation Mechanisms

A new method of estimating Tropical Tropopause Layer Cirrus (TTLC) formation mechanism (object method) is compared to interpretations of formation from previous studies using back trajectory calculations matched to convection identified from satellites and statistical relationships of TTLC with temperature and water vapor. The object method groups neighboring Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observation (CALIPSO) TTLC cloud profiles into cloud objects and classifies them as convective (35% of TTLC) if they are directly attached to a convective cloud along the CALIPSO track. The percentage of back trajectory calculations that intersect convection (39-95% of TTLC within 5 days) depends strongly on the spatial and temporal resolution of the convection data set, and the manner in which deep convection is identified. Using minimum brightness temperature in 3 hourly, 1{sup o} resolution grid boxes to define convection, 46% of non-convective TTLC (37% of all TTLC) did not trace back to convection within 24 h. Back trajectory calculations of thin cirrus identified by the High Resolution Dynamics Limb Sounder (HIRDLS) gave similar results. Temperature is not a good proxy for formation mechanism as convective and non-convective TTLC frequencies both increase monotonically with decreasing temperature at approximately the same rate. Non-convective TTLC frequencies have a stronger relationship with relative humidity than convective TTLC frequencies, though are not sufficiently different to distinguish object method categories. A decrease in TTL cirrus frequency found at low temperatures in previous studies is caused by insufficient variability in reanalysis temperature data and is not indicative of TTLC formation mechanism.

58 GEOSCIENCES↗

Measurement Uncertainty in One-Of-A-Kind Event Data Analysis

A golden standard in science is to repeat an experiment a statistically significant number of times, recording data using the same set of detectors and the same data analysis methodology. In such case experimental error includes both the range of true values generated by repetitions of the experiment, and measurement uncertainty caused by the detector. They are independent. It is a huge and too frequently used simplification, to assume that one can measure multiple repetitions of an identical experiment, resulting in identical true experimental value. Repetitions, as similar is it is experimentally achievable, have unavoidable built-in differences resulting in a range of the true values rather than in a single value. When modern, very sensitive and well calibrated measurement systems are used, this range is not negligible, and sometimes dominates over the measurement uncertainty. Range of true values depends on built-in differences in physics of the experiment. Stochastic physical processes result typically in a broader range of true values than non-stochastic processes do. Measurement uncertainty depends on a measurement method (properties of the detector not of the experiment). Modern measurement methods, including digital ones, frequently make the measurement uncertainty very small. When data from one–of –a kind experiment are analyzed, only the measurement uncertainty is reported. It provides no information about the range of true experimental values, neither about reliability of a reported data point. Reliability of a data point is in general independent from its measurement uncertainty. However, in practice reliable measurement methods frequently have high measurement uncertainty, while low reliability methods are applied to limit measurement uncertainty. Comparison of reliable data with high measurement uncertainty to not so reliable data measured with low uncertainty is discussed – in different scenarios different data analysis methods are applicable. Methods for data analysis from an experiment repeated statistically significant number of times are very well developed. They do not require a detailed expertise in physics of an experiment, nor in the properties of the measurement system used, and meaning of the reported uncertainty is well understood in any scientific community. It all changes when data from one-of-a-kind experiment is analyzed. Analyst’s expertise is required both in the physics of the experiment and in all aspects of the measurement system, all possible malfunctions. Data users must remember that only measurement uncertainty is reported from any one-of-a-kind experiment. Theory with simulations may provide estimation of expected built-in differences in the experiment, and by this of expected range of true values for a given experiment; yet measurement uncertainty can never be used in place of the range of true experimental values.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Correction of Dual-PRF Doppler Velocity Outliers in the Presence of Aliasing

Abstract In Doppler weather radars, the presence of unfolding errors or outliers is a well-known quality issue for radial velocity fields estimated using the dual–pulse repetition frequency (PRF) technique. Postprocessing methods have been developed to correct dual-PRF outliers, but these need prior application of a dealiasing algorithm for an adequate correction. This paper presents an alternative procedure based on circular statistics that corrects dual-PRF errors in the presence of extended Nyquist aliasing. The correction potential of the proposed method is quantitatively tested by means of velocity field simulations and is exemplified in the application to real cases, including severe storm events. The comparison with two other existing correction methods indicates an improved performance in the correction of clustered outliers. The technique proposed is well suited for real-time applications requiring high-quality Doppler radar velocity fields, such as wind shear and mesocyclone detection algorithms, or assimilation in numerical weather prediction models.

58 GEOSCIENCES↗

Advanced Turbulence Models for Large-Scale Atmospheric Boundary Layer Flows

We present high-fidelity large-eddy-simulation (LES) modeling approaches for the turbulent atmospheric boundary layer (ABL) flows. Wind energy is a prime example of an application driven by ABL. Generation of electrical energy from farms of wind turbines at night in the stable ABL is a particularly interesting situation. In this report, we consider the well-known GEWEX (Global Energy and Water Cycle Experiment) Atmospheric Boundary Layer Study (GABLS) stably stratified benchmark LES case. We use a high-order spectral element code Nek5000/RS, which is supported under the DOE's Exascale Computing Project (ECP) Center for Efficient Exascale Discretizations (CEED) project, targeting application simulations on various acceleration-device based exascale computing platforms. In our earlier ANL report, we demonstrated our newly developed subgrid-scale (SGS) models based on high-pass filter (HPF), mean-field eddy viscosity (MFEV), and Smagorinsky (SMG) with no-slip and traction boundary conditions, provided with low-order statistics, convergence and turbulent structure analysis. In this report, we extend the range of our SGS modeling approaches in the context of the mean-field eddy viscosity (MFEV), to include the solution of an SGS turbulent kinetic energy equation (TKE). We demonstrate the model fidelity of Nek5000/RS in comparison to that of AMR-Wind, a block-structured second-order finite-volume code with adaptive-mesh-refinement capabilities, with which we studied scaling performance for both codes in comparison on DOE's leadership computing platforms.

17 WIND ENERGY↗

Temperature statistics in a radiatively heated particle-laden turbulent square duct flow

Radiation absorption by preferentially concentrated particles in a turbulent square duct flow is studied experimentally. The particle-laden flow is exposed to near-infrared radiation, and the gas phase temperature statistics are measured along the wall bisector of the duct. It is found that the instantaneous temperature fluctuations are comparable to the overall mean temperature rise. The temperature statistics at the duct centerline and near the wall are qualitatively different. The former reflects preferential concentration in isotropic flows while the latter displays evidence of particle clustering into streamwise elongated streaks. Comparison of the experimental data to a simplified heat transfer model suggests that the Lagrangian evolution of particle clusters and voids, and turbulent mixing in the vicinity of particle clusters, are important. This work was motivated by particle solar receiver technology, but the findings are also relevant to systems where there is localized heat release or mass transfer from disperse particles or droplets. It shows that obtaining Lagrangian histories of particle trajectories is an important next step towards understanding thermal transport phenomena in particle-laden turbulent flows.

42 ENGINEERING↗

Evaluation of deformed image-based dose calculations for adaptive radiotherapy of nasopharyngeal carcinoma

The ultimate goal of adaptive radiotherapy (ART) is to deliver truly customized radiation treatments. Currently, the quality of cone-beam computed tomography (CBCT) images is still inferior to that of conventional CT images in contour delineations and dose calculations for replanning purposes. This retrospective study aims to evaluate the dosimetric accuracy of using deformed conventional CT images for dose calculations, in the hope of inferring the feasibility of ART using planning CT (PCT) images that deformed to up-to-date CBCT images for patients with nasopharyngeal carcinoma (NPC). Thirty consecutive patients with NPC who had undergone 1 replan in their radiotherapy treatments were selected. The pretreatment PCT images were deformed to match the mid-treatment PCT images by deformable image registration. The same volumetric modulated arc therapy plan was then calculated on the deformed PCT images. The resulting dose distributions and dose volume histograms of the tumors and organs at risk (OARs) were compared with the original plan. Five dose levels, D{sub 98%}, D{sub 95%}, D{sub 50%}, D{sub 5%}, and D{sub 2%}, were recorded for 9 NPC targets. Four dose levels, D{sub max}, D{sub 10%}, D{sub 50%}, and D{sub mean}, were recorded for 15 OARs. The greatest percentage difference in observed dose for D{sub 98%}, D{sub 95%}, D{sub 50%}, D{sub 5%}, and D{sub 2%} of the targets were 1.71%, 1.55%, 0.64%, 0.97%, and 1.13%, respectively. The greatest percentage difference in observed dose for D{sub max}, D{sub 10%}, D{sub 50%}, and D{sub mean} of the OARs were -26.51% (left optic nerve), -17.06% (left optic nerve), 56.70% (spinal cord), and 18.97% (spinal cord), respectively. In addition, 29 of 45 (64%) dosimetric end points of the targets showed statistically significant dose differences (p p < 0.05). Dose calculations using deformed PCT images could result in significant dose uncertainties in target volumes and OARs. Larger dose deviations were found in OARs in comparison with target volumes. The spinal cord and optic nerve showed the greatest percentage dose differences and the clinical significance has yet to be determined. Deformable registration error was believed to be the problem causing the dose deviations. Owing to unknown clinical significanceof dose deviation results obtained from this study, a conventional CT scan is still required for replanning in patients with NPC who are experiencing significant anatomical changes during the course of radiation treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Precise and direct method for the measurement of the torsion spring constant of the atomic force microscopy cantilevers

A direct method for the evaluation of the torsional spring constants of the atomic force microscope cantilevers is presented in this paper. The method uses a nanoindenter to apply forces at the long axis of the cantilever and in the certain distance from it. The torque vs torsion relation is then evaluated by the comparison of the results of the indentations experiments at different positions on the cantilever. Next, this relation is used for the precise determination of the torsional spring constant of the cantilever. The statistical analysis shows that the standard deviation of the calibration measurements is equal to approximately 1%. Furthermore, a simple method for calibration of the photodetector’s lateral response is proposed. The overall procedure of the lateral calibration constant determination has the accuracy approximately equal to 10%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multibaseline gravitational wave radiometry

We present a statistic for the detection of stochastic gravitational wave backgrounds (SGWBs) using radiometry with a network of multiple baselines. We also quantitatively compare the sensitivities of existing baselines and their network to SGWBs. We assess how the measurement accuracy of signal parameters, e.g., the sky position of a localized source, can improve when using a network of baselines, as compared to any of the single participating baselines. The search statistic itself is derived from the likelihood ratio of the cross correlation of the data across all possible baselines in a detector network and is optimal in Gaussian noise. Specifically, it is the likelihood ratio maximized over the strength of the SGWB and is called the maximized-likelihood ratio (MLR). One of the main advantages of using the MLR over past search strategies for inferring the presence or absence of a signal is that the former does not require the deconvolution of the cross correlation statistic. Therefore, it does not suffer from errors inherent to the deconvolution procedure and is especially useful for detecting weak sources. In the limit of a single baseline, it reduces to the detection statistic studied by Ballmer [Classical Quantum Gravity 23, S179 (2006).] and Mitra et al.[Phys. Rev. D 77, 042002 (2008).]. Unlike past studies, here the MLR statistic enables us to compare quantitatively the performances of a variety of baselines searching for a SGWB signal in (simulated) data. Although we use simulated noise and SGWB signals for making these comparisons, our method can be straightforwardly applied on real data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance Evaluation of a Respirator Vortex Cooling Device

The United States Department of Energy's Savannah River Site (SRS) in Aiken, South Carolina, is dedicated to promoting site-level, risk-based inspection practices to maintain a safe and productive work environment. Protective suits are worn by personnel working in contaminated environments. These suits require that cooling be applied to keep the interior temperature within safe and comfortable limits. A vortex tube, also known as the Ranque-Hilsch vortex tube (RHVT), can provide the necessary cooling. As mechanical devices void of moving components, vortex tubes separate a compressed gas into hot and cold streams—the air emerging from the “hot” end reaching a temperature of 433.2 K and the air emerging from the “cold” end reaching a temperature of 241.5 K (Hilsch, 1946, “Die Expansion Von Gasen Im Zentrifugalfeld Als Kälteprozeß,” Z. Für Naturforsch., 1, pp. 208–214). Routing the cold stream of the vortex tube to the user's protective suit facilitates the required cooling. Vortex tubes currently in use at SRS are preset, through modification solely by and within the SRS respiratory equipment facility (REF), to provide a temperature reduction between 22.2 and 25.0 K. When a new model of vortex tube capable of user adjustment during operation recently became available, prototype testing was conducted for product comparison. Ultimately, it was identified that similar cooling performance between the old and new models is achievable. Production units were acquired to be subjected to complete product analysis at SRS utilizing a statistical test plan. Finally, the statistical test plan, data, thermodynamic calculations, and conclusions were reviewed to determine acceptability for site use.

47 OTHER INSTRUMENTATION↗

Validity of the line-pair bar-pattern method in the measurement of the modulation transfer function (MTF) in megavoltage imaging

The measurement of the modulation transfer function (MTF) of an imaging device is a common requirement in evaluating radiographic detector performance. Such measurements are considered mandatory in detector development research, and may also be carried out as part of routine quality assurance (QA) checks of image quality. Traditionally, MTF measurement has been performed by imaging either a narrow slit or a sharp edge in order to generate a line spread function, whose Fourier transform provides the MTF on a near-continuous frequency domain. Much less commonly employed is the method of square-wave line-pair modulations, in which the modulation response to bar resolution targets contained in a bar pattern is used to estimate the MTF at discrete spatial frequencies. While the slit and edge methods offer advantages of accuracy and a well-known standardized protocol for measurement based on several decades of development, their major limitation is the difficult and time-consuming experimental setup that is necessary to ensure accurate measurements. On the other hand, the bar pattern offers the advantage of a quick, simple, and easy measurement without the need for a complex experimental setup, with the main disadvantages of the technique being a pseudo-normalization that may lead to an overestimated MTF, and corrections for removing higher-order frequency harmonics that require interpolating between discrete spatial frequencies. Therefore, bar patterns are traditionally used for qualitative imaging applications like detector QA in terms of relative and arbitrarily defined spatial resolution metrics, while slit and edge methods are preferred for quantitative MTF measurements. Compared to diagnostic x rays, MTF measurements using megavoltage x rays are further complicated by low x-ray attenuation and excessive Compton scattering. In this work, a method to measure the MTF of megavoltage x-ray detectors based on imaging square-wave line pairs with improved near-zero-frequency normalization was developed as an adaptation to previously reported methods. Monte Carlo simulations were used to identify an improved normalization condition with which the accuracy of the MTF determined from line-pair modulations could be enhanced considerably compared to previously used techniques. Slit, edge, and bar-pattern measurements were performed to obtain the MTF of commercial megavoltage imaging devices including portal film and electronic portal imaging devices. A comparison of the MTF measurements from the three techniques was used to ascertain the validity of the proposed bar-pattern method for accurate and reliable measurement of MTF for megavoltage imagers. Statistical analyses revealed no significant differences between the bar-pattern method and the standard slit and edge techniques, indicating very good agreement (mean difference within {+-}3%). These results indicated the potential for line-pair bar patterns to be used more effectively than in the past for traditional QA imaging as well as for quantitative MTF measurement in detector development research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling radiation loads in the ILC main linac and a novel approach to treat dark current

Electromagnetic and hadron showers generated by electrons of dark current (DC) can represent a significant radiation threat to the ILC linac equipment and personnel. In this study, a commissioning scenario is analysed which is considered as the worst-case scenario for the main linac regarding the DC contribution to the radiation environment in the tunnel. A normal operation scenario is analysed as well. An emphasis is made on radiation load to sensitive electronic equipment—cryogenic thermometers inside the cryomodules. Prompt and residual dose rates in the ILC main linac tunnels were also calculated in these new high-statistics runs. A novel approach was developed—as a part of general purpose Monte Carlo code MARS15—to model generation, acceleration and transport of DC electrons in electromagnetic fields inside SRF cavities. Comparisons were made with a standard approach when a set of pre-calculated DC electron trajectories is used, with a proper normalization, as a source for Monte Carlo modelling. Results of MARS15 Monte Carlo calculations, performed for the current main linac tunnel design, reveal that the peak absorbed dose in the cryogenic thermometers in the main tunnel for 20 years of operation is about 0.8 MGy. The calculated contact residual dose on cryomodules and tunnel walls in the main tunnel for typical irradiation and cooling conditions is 0.1 and 0.01 mSv/hr, respectively.

43 PARTICLE ACCELERATORS↗

Large eddy simulation of homogeneous isotropic turbulence

This paper presents results from a comprehensive investigation of large-eddy simulations of homogeneous isotropic turbulence. Calculations have been made using grid meshes, a number of flowfield filters, and two simple subgrid scale turbulence models. Particular attention has been paid to the degree of isotropy and the ability of the approach to predict higher-order statistical quantities (skewness and flatness). Directions for needed improvement in the simulation approach are indicated, and a plea is made to experimenters to process their data in a way which will facilitate comparison with large eddy simulations.

Ferziger, J. H.↗

The detection of the FlPi(u)-XlSigma(+)g system of diatomic carbon toward X Persei

The 0-0 vibrational band of the F1Pi(u)-X1Sigma(+)g electronic system of C2 has been detected with the IUE in the interstellar medium along the line of sight toward X Per. A column density of 3 (+ or - 1) x 10 to the 12th/f(00) per sq cm was derived by a profile fitting method. The lower limit for 0-0 band oscillator strength was determined from a comparison of the upper limits of observations of the A-X and D-X systems, and an excitation temperature of 40 K was also obtained from the profile fitting. A statistical calculation of the level population with radiative pumping shows that the 0-0 band profile corresponds to a range of values for kinetic temperature, density, and near-IR radiation. An upper limit of 50 K for kinetic temperature was determined from the statistical equilibrium analysis.

Lien, D. J.↗

Cirrus cloud statistics: Temperatures and optical depths

Measurements of the upwelling infrared radiance at 10.5 and 6.5 microns were obtained during the FIRE cirrus Intensive Field Observations using a radiometer with a 15 deg cone nadir field-of-view flown on the NASA Ames ER-2. Data are recorded at a frequency of 1 Hz and the radiometer is continuously calibrated with a liquid nitrogen blackbody source, thereby providing a large number of very accurate radiance values during the course of a several hour flight. For this study, the focus is on the statistical properties of the cirrus deck as deduced from the radiance data. The data acquired on 28 October 1986 is stressed, but some data from the other flights are also shown for comparison purposes.

Valero, Francisco P. J.↗

The cumulative cost of additional wakefulness: dose-response effects on neurobehavioral functions and sleep physiology from chronic sleep restriction and total sleep deprivation

OBJECTIVES: To inform the debate over whether human sleep can be chronically reduced without consequences, we conducted a dose-response chronic sleep restriction experiment in which waking neurobehavioral and sleep physiological functions were monitored and compared to those for total sleep deprivation. DESIGN: The chronic sleep restriction experiment involved randomization to one of three sleep doses (4 h, 6 h, or 8 h time in bed per night), which were maintained for 14 consecutive days. The total sleep deprivation experiment involved 3 nights without sleep (0 h time in bed). Each study also involved 3 baseline (pre-deprivation) days and 3 recovery days. SETTING: Both experiments were conducted under standardized laboratory conditions with continuous behavioral, physiological and medical monitoring. PARTICIPANTS: A total of n = 48 healthy adults (ages 21-38) participated in the experiments. INTERVENTIONS: Noctumal sleep periods were restricted to 8 h, 6 h or 4 h per day for 14 days, or to 0 h for 3 days. All other sleep was prohibited. RESULTS: Chronic restriction of sleep periods to 4 h or 6 h per night over 14 consecutive days resulted in significant cumulative, dose-dependent deficits in cognitive performance on all tasks. Subjective sleepiness ratings showed an acute response to sleep restriction but only small further increases on subsequent days, and did not significantly differentiate the 6 h and 4 h conditions. Polysomnographic variables and delta power in the non-REM sleep EEG-a putative marker of sleep homeostasis--displayed an acute response to sleep restriction with negligible further changes across the 14 restricted nights. Comparison of chronic sleep restriction to total sleep deprivation showed that the latter resulted in disproportionately large waking neurobehavioral and sleep delta power responses relative to how much sleep was lost. A statistical model revealed that, regardless of the mode of sleep deprivation, lapses in behavioral alertness were near-linearly related to the cumulative duration of wakefulness in excess of 15.84 h (s.e. 0.73 h). CONCLUSIONS: Since chronic restriction of sleep to 6 h or less per night produced cognitive performance deficits equivalent to up to 2 nights of total sleep deprivation, it appears that even relatively moderate sleep restriction can seriously impair waking neurobehavioral functions in healthy adults. Sleepiness ratings suggest that subjects were largely unaware of these increasing cognitive deficits, which may explain why the impact of chronic sleep restriction on waking cognitive functions is often assumed to be benign. Physiological sleep responses to chronic restriction did not mirror waking neurobehavioral responses, but cumulative wakefulness in excess of a 15.84 h predicted performance lapses across all four experimental conditions. This suggests that sleep debt is perhaps best understood as resulting in additional wakefulness that has a neurobiological "cost" which accumulates over time.

NASA Discipline Regulatory Physiology↗

Giovanni: A System for Rapid Access, Visualization and Analysis of Earth Science Data Online

Collecting data and understanding data structures traditionally are the first steps that a user must take, before the core investigation can begin. This is a time-consuming and challenging task, especially when science objectives require users to deal with large multi-sensor data that are usually in different formats and internal structures. The Goddard Earth Sciences Data and Information Services Center (GES DISC) has created the GES DISC Interactive Online Visualization and ANalysis Infrastructure, Giovanni, to enable Web-based visualization and analysis of satellite remotely sensed meteorological, oceanographic, and hydrologic data sets, without users having to download data. The current operational Giovanni interfaces provide the capability to process a number of important satellite measurements, such as (1) ozone and other trace gases from TOMS, OMI, HALOE, and MLS; (2) air temperature, water vapor, and geopotential height from AIRS; (3) aerosols from MODIS TerrdAqua, and GOCART model; (4) precipitation from TRMM and ground measurements; (5) chlorophyll and other ocean color products from SeaWiFS and MODIS Aqua; and (6) sea surface temperature from MODIS Aqua. Depending on the input data structure, the system provides simple statistical analysis and creates time-averaged area plot, area-averaged time series, animations, Hovmoller latitude vs. time and longitude vs. time plots, as well as vertical profiles. The inter-comparison interfaces allow a user to compare observations from different instruments, to conduct anomaly analysis, and to study basic relationships between physical parameters. Giovanni handles data with different temporal and spatial resolutions and, thus, enables both regional and global long-term climate research and short-term special events investigation, as well as data validations and assessments. Because of its simplicity of usage, Giovanni is powerful and versatile, able to assist a wide range of users, from the discipline scientists conducting preliminary research in various fields, to students in the classroom learning about weather, climate, and other natural phenomena. Giovanni can be accessed from: http://disc. esfc.nasa.gov/techlab/giovanni/index.shtml

Shen, S.↗