Search NASA⌕ Search

SEARCH · Search NASA

Results for “study protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

C–IBI: Targeting cumulative coordination within an iterative protocol to derive coarse-grained models of (multi-component) complex fluids

We present a coarse-graining strategy that we test for aqueous mixtures. The method uses pair-wise cumulative coordination as a target function within an iterative Boltzmann inversion (IBI) like protocol. We name this method coordination iterative Boltzmann inversion (C–IBI). While the underlying coarse-grained model is still structure based and, thus, preserves pair-wise solution structure, our method also reproduces solvation thermodynamics of binary and/or ternary mixtures. In addition, we observe much faster convergence within C–IBI compared to IBI. To validate the robustness, we apply C–IBI to study test cases of solvation thermodynamics of aqueous urea and a triglycine solvation in aqueous urea.

74 ATOMIC AND MOLECULAR PHYSICS↗

Commissioning of the discrete spot scanning proton beam delivery system at University of Texas M.D. Anderson Cancer Center, Proton Therapy Center, Houston

Purpose: To describe a summary of the clinical commissioning of the discrete spot scanning proton beam at the Proton Therapy Center, Houston (PTC-H). Methods: Discrete spot scanning system is composed of a delivery system (Hitachi ProBeat), an electronic medical record (Mosaiq V 1.5), and a treatment planning system (TPS) (Eclipse V 8.1). Discrete proton pencil beams (spots) are used to deposit dose spot by spot and layer by layer for the proton distal ranges spanning from 4.0 to 30.6 g/cm{sup 2} and over a maximum scan area at the isocenter of 30x30 cm{sup 2}. An arbitrarily chosen reference calibration condition has been selected to define the monitor units (MUs). Using radiochromic film and ion chambers, the authors have measured spot positions, the spot sizes in air, depth dose curves, and profiles for proton beams with various energies in water, and studied the linearity of the dose monitors. In addition to dosimetric measurements and TPS modeling, significant efforts were spent in testing information flow and recovery of the delivery system from treatment interruptions. Results: The main dose monitors have been adjusted such that a specific amount of charge is collected in the monitor chamber corresponding to a single MU, following the IAEA TRS 398 protocol under a specific reference condition. The dose monitor calibration method is based on the absolute dose per MU, which is equivalent to the absolute dose per particle, the approach used by other scanning beam institutions. The full width at half maximum for the spot size in air varies from approximately 1.2 cm for 221.8 MeV to 3.4 cm for 72.5 MeV. The measured versus requested 90% depth dose in water agrees to within 1 mm over ranges of 4.0-30.6 cm. The beam delivery interlocks perform as expected, guarantying the safe and accurate delivery of the planned dose. Conclusions: The dosimetric parameters of the discrete spot scanning proton beam have been measured as part of the clinical commissioning program, and the machine is found to function in a safe manner, making it suitable for patient treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Replacement correction factors for plane-parallel ion chambers in electron beams

Purpose: Plane-parallel chambers are recommended by dosimetry protocols for measurements in (especially low-energy) electron beams. In dosimetry protocols, the replacement correction factor P{sub repl} is assumed unity for ''well-guarded'' plane-parallel chambers in electron beams when the front face of the cavity is the effective point of measurement. There is experimental evidence that ion chambers which are not well-guarded (e.g., Markus) have nonunity P{sub repl} values. Monte Carlo simulations are employed in this study to investigate the replacement correction factors for plane-parallel chambers in electron beams. Methods: Using previously established Monte Carlo calculation methods, the values of P{sub repl} are calculated with high statistical precision for the cavities of a variety of plane-parallel chambers in a water phantom irradiated by various electron beams. The dependences of the values of P{sub repl} on the beam quality, phantom depth, as well as the guard ring width are studied. Results: In the dose fall-off region for low-energy beams, the P{sub repl} values are very sensitive to depth. It is found that this is mainly due to the gradient effect, which originates from the fact that the effective point of measurement for many plane-parallel chambers should not be at the front face of the cavity but rather shifted toward the center of the cavity by a fraction of a millimeter. Using the front face of the cavity as the effective point of measurement, the calculated values of P{sub repl} at d{sub ref} are not unity for some well-guarded plane-parallel chambers. The calculated P{sub repl} values for the Roos chamber are close to 1 for all electron beams. The calculation results for the Markus chamber are in good agreement with the measured values. Conclusions: The appropriate selection of the effective point of measurement for plane-parallel chambers in electron beams is an important issue. If the effective point of measurement is correctly accounted for, the P{sub repl} values would be almost independent of depth. Both the guard ring width and the ratio of the collecting volume diameter to the cavity thickness can influence the values of P{sub repl}. For a diameter to thickness ratio of 5 (e.g., NACP02 chamber), the guard width has to be 6 mm for the chamber to be considered as well-guarded, i.e., have a P{sub repl} value of 1.00.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-FG-204-09: High Spatial Resolution and Artifact-Free CT Bone Imaging at Off-Centered Positions: An Application of Model-Based Iterative Reconstruction

Purpose: Although the anatomy of interest should be positioned as close as possible to the isocenter of CT scanners, off-centering may be inevitable during certain exams in clinical practice such as lumbar spine and elbow imaging. Off-centering degrades image sharpness, generates streak artifacts, and sometimes creates blooming artifacts due to truncation. The purpose of this work was to investigate whether the use of model-based image reconstruction (MBIR) can alleviate the negative impacts of off-centering to achieve high quality CT bone imaging. Methods: Both an anthropomorphic phantom and an ex vivo swine elbow sample were scanned at centered and off-centered positions using clinical CT bone scan protocols. The magnitude of off-centering was determined from localizer radiographs. Both FBP and MBIR reconstructions were performed. For FBP, both standard and Bone Plus kernels commonly used in bone imaging were used. Objective assessment of image sharpness, noise standard deviation, and noise nonuniformity were performed. Additionally, we retrospectively analyzed human subject data acquired under off-centered conditions as a validation study. Results: In FBP images of the phantom, off-centering by 10 cm led to a 14% increase in noise (p<1e-3) and a 68% increase in noise nonuniformity (p<0.02). A visible drop in bone sharpness was observed. In contrast, no significant difference in the noise magnitude or the noise nonuniformity between the centered and off-centered MBIR images was found. The image sharpness of off-centered MBIR images outperformed that of FBP images reconstructed with the Bone Plus kernel. In images of the swine elbow off-centered by 20 cm, not only was the noise and spatial resolution performance improved by MBIR, truncation artifacts were also elliminated. The human subject study generated similar results, in which the visibility of the off-centered lumbar spine was significantly improved. Conclusion: High quality CT bone imaging at off-centered positions can be achieved using MBIR. This work was partially supported by an NIH grant R01CA169331 and GE Healthcare. K. Li, D. Gomez-Cardona: Nothing to disclose. G.-H. Chen: Research funded, GE Healthcare; Research funded, Siemens AX. A. Budde, J. Hsieh: Employee, GE Healthcare.

60 APPLIED LIFE SCIENCES↗

FACE-MDS Phase 2: Data from Six US-Located Elevated CO2 Experiments

This dataset contains measured ecosystem data from four Free Air CO2 Enrichment (FACE) experiments–Duke, Oak Ridge (ORNL), and Rhinelander -- and one Open Top Chamber (OTC) experiment -- Kennedy Space Center (KSCO). The sites were located in the United States and contain data from 1996-2009. These sites were the study sites of the FACE Model Data Synthesis (FACE-MDS) project phase 2. The file naming convention can be found in the file 'facemds-file-table-sitedata.xml' and information about variable naming convention can be found in the file 'facemds-standard-name-table-modvars.xml'. We followed the ALMA v3 convention for meteorological variables and developed a hierarchical naming scheme for ecosystem variables. Additional info can be found in the protocols in the accompanying meteorological dataset (Walker et al. 2018: doi:10.15485/1480328). We replaced the original naming convention mentioned in the protocol with the one described in 'facemds-standard-name-table-modvars.xml'. The outputs of the FACE-MDS phase 2 are in Walker et al (2018: doi:10.15485/1480327). The dataset contains 18 data files that are available in comma-separate (*.csv), and 18 R Data Serialization (*.rds) format. 2 XML (*.xml) companion files and additional metadata are provided: 2 data dictionaries and a file-level metadata file in comma-separate (.csv) format and a user guide in PDF (*.pdf) format. This dataset was updated on 2019-06-28 to fix daily files at Duke and ORNL were incorrectly labelled and were standard error files instead of plot level data. Now corrected and all three (plot, mean, standard error) daily data files for both sites have been added. This dataset was updated on 2026-06-08 to add a user guide, data dictionary file, and a file-level metadata file. DUKE_ax_v2.csv was added to match the no data value format of other files in this dataset. DUKE_ax.csv is maintained as a data file. No previously released data values were changed.

54 ENVIRONMENTAL SCIENCES↗

ETF Grout Expansion: Evaluation of MgO Additions and Struvite Precipitation Protocol for Potential Expansion

The ETF ammonia tolerant grout waste form was developed by the Vitreous State Laboratory (VSL) to stabilize ammonium and thereby prevent emission of ammonia vapor during solidification of an ammonium-rich, concentrated sulfate aqueous waste stream generated at the Hanford Effluent Treatment Facility (ETF). VSL did not observe expansion in samples prepared during the waste form development work. However, Savannah River National Laboratory (SRNL) personnel did encounter expansion, in some cases up to 20+ volume percent expansion in ETF grout samples while preforming work scope to evaluate compositional ranges for ETF brine and of the precipitation and solidification reagent. The work requests can be found in Washington River Protection Services (WRPS) Statement of Work (SOW), Requisitions #: 339922 Revisions 0 and 1, March 11, 2021, and November 2021. Additional evaluation was requested by WRPS SOW Requisitions #: 356730, Revision 1, February 1, 2022, to determine whether differences in the slags or differences in sample preparation protocols used by VSL and SRNL were the cause of the expansion observed in the SRNL samples. G. Chen, WRPS, arranged a materials exchange between VSL and SRNL and coordinated the VSL protocol for grouting and curing 1L of Base Case ETF simulant. Materials were exchanged between VSL and SRNL and both laboratories performed the VSL struvite precipitation-solidification protocol and cured samples for at least 28 days. VSL and SRNL encountered expansion, at varying degrees, in all samples prepared under the material exchange and grouting protocol. Additional material exchange testing between VSL and SRNL and alternative materials evaluation to further investigate the causes of grout expansion and differentiate the effects of various dry materials, grouting procedures, and curing containers was requested by WRPS SOW Requisitions #: 356730, Revision 2, January 10, 2023. Pacific Northwest National Laboratory (PNNL) assembled and distributed materials to both laboratories for testing. Observations from this study indicated variations in MgO additions, water-to-dry mix (dm) ratios and curing containers did not correlate to ETF ammonia grout expansion. In comparison to previous work, SRNL observed the addition rate of NaOH to be a potential factor for the final pH in the struvite precipitation step. In the current testing NaOH was added in bulk (5-10 mL at one time) during the precipitation step. The resulting pH was 7.57-9.15 which is slightly higher than pH observed at a slower addition rate. Additional testing is needed to identify the presence and/or struvite stability in high-pH struvite precipitant ETF ammonia grout samples. Therefore, based on current data, it is unknown if NaOH addition rate is the fundamental cause of grout expansion.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Field Emission Analysis in SRF Cavities for PIP-II Using GEANT4

Field emission (FE) remains a significant hurdle for achieving optimal performance and reliability in superconducting radiofrequency (SRF) cavities used in accelerator cryomodules. A thorough understanding of the generation and propagation of FE-induced radiation is therefore essential to mitigate this problem. The absence of standardized measurement protocols further complicates the comparison of radiation data across different testing phases and facilities. This highlights the need for a precise quantitative method to diagnose and analyze FE-induced radiation. Such efforts could prove beneficial for improving cavity preparation and cleanroom assembly techniques during the prototype and production stages of Fermilab's Proton Improvement Plan-II (PIP-II) project. This study presents the initial steps of detailed Geant4 simulations aimed at analyzing FE-induced radiation in the low-beta 650 MHz 5-cell elliptical (LB650) cavity. Our goal is to combine these results with radiation diagnostics to enhance diagnostic accuracy and optimize detector positioning. This integrated approach ultimately aims to improve the preparation, assembly, and testing procedures for PIP-II SRF cavities, ensuring the delivery of FE-free cryomodules.

Wijethunga, Sajini A.K. [Fermilab] (ORCID:00000002↗

Error Detection and Error Classification: Failure Awareness in Data Transfer Scheduling

Data transfer in distributed environment is prone to frequent failures resulting from back-end system level problems, like connectivity failure which is technically untraceable by users. Error messages are not logged efficiently, and sometimes are not relevant/useful from users point-of-view. Our study explores the possibility of an efficient error detection and reporting system for such environments. Prior knowledge about the environment and awareness of the actual reason behind a failure would enable higher level planners to make better and accurate decisions. It is necessary to have well defined error detection and error reporting methods to increase the usability and serviceability of existing data transfer protocols and data management systems. We investigate the applicability of early error detection and error classification techniques and propose an error reporting framework and a failure-aware data transfer life cycle to improve arrangement of data transfer operations and to enhance decision making of data transfer schedulers.

97 MATHEMATICS AND COMPUTING↗

Evaluation of Alternative Refrigerants for Mini-Split Air Conditioners

The phase-out of hydrochlorofluorocarbons (HCFC) refrigerants in developing countries is currently underway according to the Montreal Protocol. R-22 is one of the most commonly used HCFCs in the developing nations. It is extremely well suited for air conditioning and refrigeration (AC&R) in high ambient temperature environments. Non-Article 5 countries have already gone through the phase-out of HCFCs and settled on using R-410A as the refrigerant of choice for AC applications. Previous studies have shown that R-410A results in significant capacity and performance degradation at higher ambient temperature conditions. As such, there is a growing concern on finding alternative refrigerants to R-22 that would have zero ODP, lower GWP, and at the same time maintain acceptable performance at higher ambient temperatures. Furthermore, the developed world s transition through higher global warming potential (GWP) refrigerants like HFC and HFC blends resulted in significant direct CO2 equivalent emissions. It is imperative to develop a bridge for developing nations to avoid the transition from HCFC to HFC and then from HFC to alternative lower GWP refrigerants. This paper summarizes data from an experimental campaign on alternative refrigerant evaluation for R-22 and R-410A substitutes for mini-split air conditioners designed for high ambient environments. The experimental evaluation was performed according to ANSI/ASHRAE Standard 37 and the performance was rated at test conditions specified by ANSI/AHRI 210-240 and ISO 5151. Additional tests were conducted at outdoor ambient temperatures of 52 C (125.6 F) and 55 C (131 F) to evaluate their performance at high ambient conditions. Alternative refrigerants, some of which are proprietary, included R-444B, DR-3, N-20b, ARM-20b, R-290, and DR-93 as alternatives to R-22 and R-32, DR-55, L41-2, ARM-71A, and HPR-2A as alternatives to R-410A. The units performances were first verified using the baseline refrigerant and then drop-in refrigerant evaluation followed including soft optimization to ensure refrigerant performance is adequately represented. The soft optimization included: 1) charge optimization, 2) lubricant change, and 3) flow control. The paper presents the relative performances (efficiency and capacity) of the alternative refrigerants compared to the baseline refrigerants at the different operating conditions. Paper concludes with remarks about the suitability of alternative refrigerants for R-22 and R-410A applications in high ambient temperature regions.

Alternative Refrigerant↗

Field Emission Analysis in SRF Cavities for PIP-II Using GEANT4

Field emission (FE) remains a significant hurdle for achieving optimal performance and reliability in super-conducting radiofrequency (SRF) cavities used in accelerator cryomodules. A thorough understanding of the generation and propagation of FE-induced radiation is therefore essential to mitigate this problem. The absence of standardized measurement protocols further complicates the comparison of radiation data across different testing phases and facilities. This highlights the need for a precise quantitative method to diagnose and analyze FE-induced radiation. Such efforts could prove beneficial for improving cavity preparation and cleanroom assembly techniques during the prototype and production stages of Fermilab's Proton Improvement Plan-II (PIP-II) project. This study presents the initial steps of detailed Geant4 simulations aimed at analyzing FE-induced radiation in the low-beta 650 MHz 5-cell elliptical (LB650) cavity. Our goal is to combine these results with radiation diagnostics to enhance diagnostic accuracy and optimize detector positioning. This integrated approach ultimately aims to improve the preparation, assembly, and testing procedures for PIP-II SRF cavities, ensuring the delivery of FE-free cryomodules.

Wijethunga, S. A.K. [Fermilab] (ORCID:000000028765↗

Site and endmember spectra of terrestrial vegetation and soils for the Colorado Headwaters Ecological Spectroscopy Study, June-July 2025

This dataset provides site and endmember spectra collected during the 2025 Colorado Headwaters Ecological Spectroscopy Study (CHESS) campaign. The site spectra were collected to help validate airborne hyperspectral data acquired by the National Ecological Observatory Network's aerial observation platform (NEON AOP). Endmember spectra were collected to augment existing spectral libraries with additional samples of bare surfaces and non-photosynthetic vegetation. All measurements were acquired with an Analytical Spectral Devices (ASD) FieldSpec4 Hi-Res NG (Next Generation) spectroradiometer, which records radiance at 1nm (nanometer) intervals from the ultraviolet to the short-wave infrared (350-2500 nm). The dataset includes spectra measured at meadow sites where the CHESS team also collected vegetation samples for trait analyses. The site spectra were collected with the ASD FieldSpec4 palm grip attachment using an 8° field-of-view foreoptic. Site spectra are integrated measurements of the entire surface within the foreoptic’s field of view. For site-level spectra, the sun is the illumination source. A Spectralon panel mounted on a tripod was used for instrument optimization and white reference measurements for all site spectra. Site spectra were acquired within two hours of solar noon and within 48 hours of a NEON AOP overflight. Site spectra are labeled by date, sampling area, and site number according to the naming conventions of the CHESS campaign’s data management plan. The dataset also contains endmember spectra in the following categories: photosynthetic vegetation (PV), non-photosynthetic vegetation (NPV), bare (soil/rock), and flowers. Endmember measurements were acquired using either the contact probe or the leaf clip attachments of the ASD FieldSpec4. In these configurations, the bulb inside the spectrometer provides the light source for the measurements. The spectrometer was optimized and white reference measurements were recorded using the circular white pucks attached to the contact probe and leaf clip. Because they do not rely on solar illumination, contact probe and leaf clip measurements were collected during a broader time frame than the palm grip site spectra. Some endmembers were measured at CHESS meadow sites, while others were collected within the larger sampling area or in nearby locations (e.g. Gothic Townsite) with similar characteristics. Radiance, reflectance, and metadata files are split into three subfolders according to measurement type: proximal/palm grip (prx), contact probe (cp), and leaf clip (lc). Radiance spectra are provided in ASD file format (.asd file extension). All ASD files can be opened using the provided scripts. Metadata is provided in two formats: CSV file format (no geolocation) and GEOJSON file format (includes geolocation for each spectra). The dataset includes a set of pre-processed reflectance spectra as CSV files (yyyymmdd_rfl.csv). The python scripts and jupyter notebook used to calculate reflectance spectra from the ASD radiance data is included here and was previously published at: https://doi.org/10.3334/ORNLDAAC/2446. There is also a folder of JPEG photographs corresponding to selected spectra. We include a protocol document with detailed steps for ASD FieldSpec4 assembly and operations. This data additionally contains a file level metadata (flmd.csv) and data dictionary (dd.csv) file. Geospatial information: Geospatial data for mapping measurement site locations are in the files CHESS_polygons_lai_UTM.geojson, CHESS_polygons_shrub_UTM.geojson, and CHESS_polygons_meadow_UTM.geojson in the companion geospatial package for the 2025 CHESS campaign, ‘CHESS 2025: Location data for field observations and sampling’ (Henderson et al., 2026). CHESS Project Description: The Colorado Headwaters Ecological Spectroscopy Study (CHESS) comprised a multi-week airborne remote sensing and field observation campaign in the Upper Gunnison Basin, Colorado, conducted in June and July of 2025. Airborne remote sensing was conducted by the National Ecological Observatory Network Airborne Observation Platform (NEON AOP), concurrent with a field campaign run by the Rocky Mountain Biological Laboratory (RMBL), the Lawrence Berkeley National Laboratory (LBNL) and SLAC National Accelerator Laboratory Watershed Function Science Focus Area (SFA), and NASA-JPL (Jet Propulsion Laboratory) Earth Surface Mineral Dust Source Investigation (EMIT) program. Between June 10 and July 18, 2025, the NEON AOP flight team collected high-resolution aerial imaging spectroscopy and Light Detection and Ranging (LiDAR) data over three domains: the Upper East River (CRBU), Almont Triangle (ALMO), and the Upper Taylor Basin (UPTA). In coordination with the flights, a field campaign acquired ground-truth observations, including observations of vegetation composition, foliar traits, forest demography, and subsurface properties in 18 core sampling areas within the domains. Additional surface water observations were taken at over 380 point locations. All CHESS campaign datasets can be found within the CHESS ESS-DIVE data portal: https://data.ess-dive.lbl.gov/portals/chess. Funding Acknowledgment: This research was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under a contract with the National Aeronautics and Space Administration (80NM0018D0004) and was funded by EMIT Extended Mission Phase E Science.

2018 NEON and 2025 CHESS Campaigns↗

Assessment of Condition Monitoring Methods and Technologies for Inservice Inspection and Testing of Nuclear Power Plant Components

This report was prepared for the U.S. Nuclear Regulatory Commission (NRC) to explore the application of advanced technologies toward meeting the current and future regulatory requirements for maintenance and condition monitoring of structures, systems, and components. The advanced technologies considered in this work are advanced sensors and instrumentation, data analytics, machine learning and artificial intelligence (ML/AI), physics-based models, and digital twins (DT). The interest in the application of advanced technologies for condition monitoring in nuclear power plants continues to grow, and current and future licensees are expected to implement advanced technologies as part of their inservice inspection (ISI) and inservice testing (IST) programs. This report delineates the outcomes of an exploratory investigation into the implementation of advanced condition monitoring technologies to address ISI and IST requirements. A thorough review was conducted of the existing regulatory requirements for ISI and IST, along with an analysis of associated industry practices. Additionally, a state-of-the-art assessment was performed on advanced condition monitoring technologies frequently employed in non-nuclear sectors. This research incorporated two nuclear-specific case studies to illustrate the application of these technologies within the current nuclear fleet. The report provides an exhaustive discussion on the technical challenges, considerations, and opportunities associated with the deployment of advanced condition monitoring technologies. The following are key considerations in the application of advanced technologies for the ISI and IST of nuclear power plant components: • Developing adequate verification and validation procedures to confirm the functional and non-functional requirements, • Developing technical capabilities to conduct real-time asset condition monitoring, • Establishing guidance and protocol for modeling and simulation tools to continuously meet regulatory requirements, • Addressing trustworthiness, explainability, and interpretability of ML/AI methods, • Evaluating maintenance activities to maintain an adequate safety margin and avoid undesirable conditions, • Establishing cybersecure condition monitoring programs associated with a computer-based software system, and • Establishing standardized evaluation metrics for advanced condition monitoring programs. Interest in the use of advanced technologies for condition monitoring in ISI and IST programs continues to grow, and the technology is expected to experience rapid and wide industry adoption in the near future. Adoption of advanced technologies for condition monitoring could have novel and unique impacts on regulatory activities associated with ISI and IST programs. The NRC is continuing to explore the regulatory aspects of advanced technologies as part of ISI and IST programs by pursuing additional research in this technical area.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Double conical crystal x-ray spectrometer for high resolution ultrafast x-ray absorption near-edge spectroscopy of Al K edge

An x-ray spectrometer devoted to dynamical studies of transient systems using the x-ray absorption fine spectroscopy technique is presented in this article. Using an ultrafast laser-induced x-ray source, this optical device based on a set of two potassium acid phthalate conical crystals allows the extraction of x-ray absorption near-edge spectroscopy structures following the Al absorption K edge. The proposed experimental protocol leads to a measurement of the absorption spectra free from any crystal reflectivity defaults and shot-to-shot x-ray spectral fluctuation. According to the detailed analysis of the experimental results, a spectral resolution of 0.7 eV rms and relative fluctuation lower than 1% rms are achieved, demonstrated to be limited by the statistics of photon counting on the x-ray detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First-principles thermodynamic screening approach to photo-catalytic water splitting with co-catalysts

We adapt the computational hydrogen electrode approach to explicitly account for photo-generated charges and use it to computationally screen for viable catalyst/co-catalyst combinations for photo-catalytic water splitting. The hole energy necessary to thermodynamically drive the reaction is employed as descriptor for the screening process. Using this protocol and hybrid-level density-functional theory, we show that water oxidation on bare TiO{sub 2} surfaces is thermodynamically more complex than previously thought. This motivates a screening for suitable co-catalysts for this half-reaction, which we carry out for Au particles down to the non-scalable size regime. We find that almost all small Au clusters studied are better suited for water photo-oxidation than an extended Au(111) surface or bare TiO{sub 2} facets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TH-AB-201-09 [Medical Physics, Jun 2016, v. 43(6)]

Purpose: To determine the k-(Q-msr,Q)^(f-msr,f-ref ) factor, introduced in the small field formalism for five common type chambers used in the calibration of Leksell Gamma-Knife Perfexion model over a range of different phantom electron densities. Methods: Five chamber types including Exradin-A16, A14SL, A14, A1SL and IBA-CC04 are modeled in EGSnrc and PENELOPE Monte Carlo codes using the blueprints provided by the manufacturers. The chambers are placed in a previously proposed water-filled phantom and four 16-cm diameter spherical phantoms made of liquid water, Solid Water, ABS and polystyrene. Dose to the cavity of the chambers and a small water volume are calculated using EGSnrc/PENELOPE codes. The calculations are performed over a range of phantom electron densities for two chamber orientations. Using the calculated dose-ratio in reference and machine specific reference field, the k-(Q-msr,Q)^(f-msr,f-ref ) factor can be determined. Results: When chambers are placed along the symmetry axis of the collimator block (z-axis), the CC04 requires the smallest correction followed by A1SL and A16. However, when detectors are placed perpendicular to z-axis, A14SL needs the smallest and A16 the largest correction. Moreover, an increase in the phantom electron density results in a linear increase in the k-(Q-msr,Q)^(f-msr,f-ref ). Depending on the chambers, the agreement between this study and a previous study performed varies between 0.05–0.70% for liquid water, 0.07–0.85% for Solid Water and 0.00–0.60% for ABS phantoms. After applying the EGSnrc-calculated k-(Q-msr,Q)^(f-msr,f-ref ) factors for A16 to the previously measured dose-rates in liquid water, Solid Water and ABS normalized to the dose-rate measured with TG-21 protocol and ABS phantom, the dose-rate ratios are found to be 1.004±0.002, 0.996±0.002 and 0.998±0.002 (3σ) respectively. Conclusion: Knowing the electron density of the phantoms, the calculated k-(Q-msr,Q)^(f-msr,f-ref ) values in this work will enable users to apply the appropriate correction for their own specific phantom material. LM acknowledges partial support by the CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council (Grant number: 432290)

60 APPLIED LIFE SCIENCES↗

Simplified Ab Initio Molecular Dynamics-Based Raman Spectral Simulations

We describe a simplified approach to simulating Raman spectra from ab initio molecular dynamics (AIMD) calculations. The protocol relies on on-the-fly calculations of approximate molecular polarizabilities using the well-known sum over orbitals (as opposed to states) method. This approach bypasses the more accurate but computationally expensive approach to calculating molecular polarizabilities along AIMD trajectories, i.e., solving the coupled perturbed Hartree–Fock/Kohn–Sham equations. We demonstrate the advantages and limitations of our method through a few case studies targeting molecular systems of interest to surface- and/or tip-enhanced Raman spectroscopy practitioners.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spatial Study 2022: Surface Water Samples, Cotton Strip Degradation, and Hydrologic Sensor Data across the Yakima River Basin, Washington, USA (v3)

This dataset supports a broader study examining the drivers of spatial variability in sediment respiration rates in the Yakima River Basin. The dataset provides data and photos generated from sample collection during the same one-week period at 48 sites within multiple rivers throughout the Yakima River Basin in Washington, USA. The contents include surface water geochemistry data; river substrate grain size photos; stream depth data; manual chamber open channel respiration data; and field metadata (including qualitative information on instream and river corridor characteristics). Grain size photos can be used to improve estimates of channel substrate D50 data. The dataset also includes tensile strength and photos from cotton strip field degradation experiments; five-week sensor time series temperature, dissolved oxygen, pressure, pH, specific conductance, chlorophyll A, and turbidity data; plots of the sensor data; and R scripts used to generate the plots. Samples collected during this study were labeled as “Second Spatial Study” or “SSS.” A subset of data from the SSS samples were published in the contiguous United States (CONUS)-Scale Model-Sample (CM) study data package available at https://data.ess-dive.lbl.gov/view/doi:10.15485/1923689 that presents data from across the CONUS. SSS data published in the CM data package were not included in this data package. They include dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC), total nitrogen (TN), grain size, aerobic sediment respiration, dissolved oxygen (DO), and temperature. Parent IDs and Site IDs are consistent between the SSS and CM data packages, and they can be mapped directly so data across packages can be used together. Additionally, sensor data from a similar 2021 spatial study can be found at https://data.ess-dive.lbl.gov/view/doi:10.15485/1892052 and 2021 sample data can be found at https://data.ess-dive.lbl.gov/view/doi:10.15485/1898914. The 2021 spatial study had some sites in common with this 2022 spatial study. This dataset is comprised of three photo folders and one main data folder with six subfolders. The photo folders contain photographs and videos of cotton strip retrieval and sediment quadrats. The main data folder consists of (1) file-level metadata; (2) data dictionary; (3) field metadata; (4) total suspended solids (TSS) data and cotton strip tensile strength data and averages; (5) field protocol; (6) readme; (7) methods codes; (8) international generic sample number (IGSN) mapping file; (9) sensor installation methods summary; (10) stream depth and averages; and (11) Ultrameter data and averages. The Sonar subfolder consists of Sonar time-series depth data and a processing script. The BarotrollAtm, DepthHOBO, MantaRiver, miniDOT, and miniDOTManualChamber subfolders contain time-series data, plots, and summary files. All files are .csv, .pdf, .txt, .R, .Rmd, .jpg, .jpeg, .AVI, .mp4, or .mov. The data package was originally published in April 2023. It was updated in August 2023 (v2; modified files) and September 2024 (v3; modified files). See the change history section in the readme for details. We acknowledge the Yakama Nation as owners and caretakers of the lands where we collected these data. We thank the Confederated Tribes and Bands of the Yakama Nation Tribal Council and Yakama Nation Fisheries for working with us to facilitate sample collection and optimization of data usage according to their values and worldview.

54 ENVIRONMENTAL SCIENCES↗

Refrigerants for a Sustainable Future

Worldwide use of high global warming potential (GWP) hydrofluorocarbon (HFC) refrigerants for space conditioning and food storage results in significant equivalent greenhouse gas (GHG) emissions. This is further exacerbated in developed countries by the current transition from hydrochlorofluorocarbon (HCFC) refrigerants to HFC refrigerants. Under the Kigali amendment to the Montreal Protocol, the proposed phase-out of currently used HFC and HCFC refrigerants has initiated a re-evaluation of some pre-existing refrigerants as well as the development and evaluation of new refrigerants. Making the ideal refrigerant selections for heating, ventilation, air-conditioning, and refrigeration (HVAC&R) applications is thereby difficult in an already overabundant refrigerants market. In this paper, a study of key parameters required of a good refrigerant is conducted, followed by the analysis of refrigerants desired and refrigerants used in two major sectors of the HVAC&R industry, namely commercial refrigeration and residential air-conditioning and heat pumps. Finally, keeping in consideration the global environmental regulations and safety standards, a recommendation of the most suitable refrigerants in both sectors has been made.

54 ENVIRONMENTAL SCIENCES↗