Search NASA⌕ Search

SEARCH · Search NASA

Results for “timing error evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

MODELING AND PARAMETRIC STUDY OF END-GAS AUTOIGNITION TO ALLOW THE REALIZATION OF ULTRA-LOW EMISSIONS, HIGH-EFFICIENCY HEAVY-DUTY SPARK-IGNITED NATURAL GAS ENGINES

Engine knock and misfire are barriers to pathways leading to high-efficiency Spark-Ignited (SI) Natural Gas (NG) engines. The general tendency to knock is highly dependent on engine operating conditions and the fuel reactivity. The problem is further complicated by the low emission limits and the wide range of chemical reactivity in pipeline-quality natural gas. Depending on the region and the source of the natural gas, its reactivity, described by its Methane Number (MN), which is analogous to the Octane Number for liquid SI fuels, can span from 65 to 95. In order to realize diesel-like efficiencies, SI NG engines must be designed to operate at high Brake Mean Effective Pressures (BMEP), near or beyond knock limits, over a wide range of fuel reactivity. This requires a deep understanding of the combustion-engine interactions pertaining to flame propagation and End-Gas Autoignition (EGAI), i.e., the autoignition of the unburned gas (end gas) ahead of the flame front. However, EGAI, if controlled, provides an opportunity to increase SI NG engine efficiency by increasing the combustion rate and the total fraction of burned fuel, mitigating the effects of the slow flame speeds characteristic of natural gas fuels, which generally reduce BMEP and increase unburned hydrocarbon emissions. For this reason, to realize diesel-like efficiencies and ultra-low emissions on SI NG engines, this work proposes the study of the main parameters influencing the modeling and prediction of NG EGAI to allow for its control. In this work, a novel EGAI detection and onset determination method was developed to reliably quantify EGAI for data analysis and engine control. The new method allowed the prediction of EGAI on SI NG engines without the need to use engine- and operating-condition-dependent thresholds and reduced the error in quantifying the fraction of the total energy released by the EGAI event by up to 40%pts. One- and three-dimensional engine models were then developed to study the engine/fuel interactions that lead to NG EGAI and its performance benefits. These models, although having decent agreement with experimental data, showed the need to account for NOx chemistry when predicting NG EGAI due to a consistently later prediction of the EGAI onset (~1.65 crank-angle degrees) and thus, a new reduced chemical mechanism for real NG fuels was developed containing NOx chemistry. The new reduced mechanism improved the EGAI onset prediction agreement to within ±0.5 crank-angle degrees and decreased simulation time during combustion by nearly 50% when using the further reduced AREIS50NOx chemical mechanism. These models were then used to study the role of NG composition on EGAI, evaluate the engine/fuel interactions leading to NG EGAI, and perform engine optimization while leveraging EGAI to increase thermal efficiency. Piston design optimization combined with a Controlled EGAI (C-EGAI) combustion mode allowed a Heavy-Duty (HD) SI NG engine to operate at diesel-like efficiencies, i.e., Brake Thermal Efficiency (BTE) ≥44%. Experimental and modeling data analysis revealed that earlier and faster heat release increases combustion efficiency by an average of 1%pts, increases work transferred to the piston resulting in a decrease in exhaust losses by 50% depending on the engine operating condition while slightly increasing heat losses. Finally, the simulation results revealed an opportunity to further enhance the BTE (up to 50%) by enabling C-EGAI combustion at leaner conditions, λ=1.4-1.6.

Bestel, Diego Bernardi↗

THE DEMOGRAPHICS OF BROAD-LINE QUASARS IN THE MASS-LUMINOSITY PLANE. II. BLACK HOLE MASS AND EDDINGTON RATIO FUNCTIONS

We employ a flexible Bayesian technique to estimate the black hole (BH) mass and Eddington ratio functions for Type 1 (i.e., broad line) quasars from a uniformly selected data set of {approx}58, 000 quasars from the Sloan Digital Sky Survey (SDSS) DR7. We find that the SDSS becomes significantly incomplete at M {sub BH} {approx}< 3 Multiplication-Sign 10{sup 8} M {sub Sun} or L/L {sub Edd} {approx}< 0.07, and that the number densities of Type 1 quasars continue to increase down to these limits. Both the mass and Eddington ratio functions show evidence of downsizing, with the most massive and highest Eddington ratio BHs experiencing Type 1 quasar phases first, although the Eddington ratio number densities are flat at z < 2. We estimate the maximum Eddington ratio of Type 1 quasars in the observable universe to be L/L {sub Edd} {approx} 3. Consistent with our results in Shen and Kelly, we do not find statistical evidence for a so-called sub-Eddington boundary in the mass-luminosity plane of broad-line quasars, and demonstrate that such an apparent boundary in the observed distribution can be caused by selection effect and errors in virial BH mass estimates. Based on the typical Eddington ratio in a given mass bin, we estimate growth times for the BHs in Type 1 quasars and find that they are comparable to or longer than the age of the universe, implying an earlier phase of accelerated (i.e., with higher Eddington ratios) and possibly obscured growth. The large masses probed by our sample imply that most of our BHs reside in what are locally early-type galaxies, and we interpret our results within the context of models of self-regulated BH growth.

79 ASTRONOMY AND ASTROPHYSICS↗

Factors Affecting Prostate Volume Estimation in Computed Tomography Images

The aim of this study was to investigate how apex-localizing methods and the computed tomography (CT) slice thickness affected the CT-based prostate volume estimation. Twenty-eight volunteers underwent evaluations of prostate volume by CT, where the contour segmentations were performed by three observers. The bottom of ischial tuberosities (ITs) and the bulb of the penis were used as reference positions to locate the apex, and the distances to the apex were recorded as 1.3 and 2.0 cm, respectively. Interobserver variations to locate ITs and the bulb of the penis were, on average, 0.10 cm (range 0.03-0.38 cm) and 0.30 cm (range 0.00-0.98 cm), respectively. The range of CT slice thickness varied from 0.08-0.48 cm and was adopted to examine the influence of the variation on volume estimation. The volume deviation from the reference case (0.08 cm), which increases in tandem with the slice thickness, was within {+-} 3 cm{sup 3}, regardless of the adopted apex-locating reference positions. In addition, the maximum error of apex identification was 1.5 times of slice thickness. Finally, based on the precise CT films and the methods of apex identification, there were strong positive correlation coefficients for the estimated prostate volume by CT and the transabdominal ultrasonography, as found in the present study (r > 0.87; p < 0.0001), and this was confirmed by Bland-Altman analysis. These results will help to identify factors that affect prostate volume calculation and to contribute to the improved estimation of the prostate volume based on CT images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ion-chain sympathetic cooling and gate dynamics

Sympathetic cooling is a technique often employed to mitigate motional heating in trapped-ion quantum computers. However, choosing system parameters such as number of coolants and cooling duty cycle for optimal gate performance requires evaluating trade-offs between motional errors and other slower errors such as qubit dephasing. The optimal parameters depend on cooling power, heating rate, and ion spacing in a particular system. In this study, we aim to analyze best practices for sympathetic cooling of long chains of trapped ions using analytical and computational methods. We use a case study to show that optimal cooling performance is achieved when coolants are placed at the center of the chain and provide a perturbative upper bound on the cooling limit of a mode given a particular set of cooling parameters. In addition, using computational tools, we analyze the trade-off between the number of coolant ions in a chain and the center-of-mass mode heating rate. We also show that cooling as often as possible when running a circuit is optimal when the qubit coherence time is otherwise long. These results provide a roadmap for how to choose sympathetic cooling parameters to maximize circuit performance in trapped-ion quantum computers using long chains of ions.

Cooling & trapping↗

Numerical and experimental evaluation for single-axis control of an LSS laboratory model

One of the major problems of LSS attitude control design stems from the modeling uncertainties due to modal truncation errors and modal parameter estimation errors. This modeling problem is investigated by evaluating poles and zeros of the frequency response functions, described in terms of constrained or unconstrained modes. The frequency domain approach is utilized to evaluated the results of modal analyses and direct output feedback controller experiments using a simple flexible spacecraft model consisting of a rigid primary body and flexible aluminum beam(s) with a control moment gyro as an actuator. The modal data are compared under the conditions that the model is constrained as the canti-lever and it is rotationally free on a single-axis air bearing table. In addition, the open-loop responses are experimentally examined under the impulsive disturbance to the appendage. The results of the control experiments show that the first vibration mode of the appendage and the interacted rotational motion of the primary body are damped in a short time as predicted by the numerical analysis, to produce damping ratio of 10-20%.

Ohkami, Y.↗

Regional Climate and Variability of the Summertime Continental United States in Reanalyses

Understanding climate variability at regional scales is an important for research and societal needs. Atmospheric retrospective-analyses (or reanalyses) integrate multitudes of observing systems with numerical models to produce continuous data that include variables not easily observed, if at all. The breadth of variables as well as observational influence included in reanalyses make them ideal for investigating climate variability. In this paper, we assess NASA s Modern Era Retrospective-analysis for Research and Application (MERRA) regional variability in North America, specifically the United States, in conjunction with current satellite data reanalyses. Emphasis is placed on summertime precipitation because 1) it is a difficult parameter to capture in the most difficult season, 2) significant observational resources exist to benchmark comparisons, and 3) accurate assessment of precipitation variability is crucial to a multitude of sectors and applications. Likewise, we have also begun to evaluate surface air temperature. While precipitation biases are identified, year to year variability of the precipitation variations, in many cases, are quite reasonable. However, some spurious long term trends and sudden shifts in the time series are also identified. In surface air temperature, analysis of station observations provides ERA Interim a clear overall advantage. However, in a number of regions, all the reanalyses are quite comparable in variability and trend. In other regions, significant precipitation biases may occur, which has implications for the ancillary process data in a reanalysis, such as surface fluxes. We also characterize the reanalyses ability to capture variability related to ENSO. In general, the summertime variations of precipitation in the reanalyses are more highly correlated (positively) to ENSO (using ENSO34) than are the observations. The Northwestern US shows the largest positive correlations to ENSO34, and reanalyses agree with that, and correlate highly with the gauge observations there. Additional evaluation of the data assimilation using the MERRA Gridded Innovations and Observations (GIO) data, which consists of the assimilated observations as well as forecast an analysis error fields. This work represents an initial evaluation of using the MERRA reanalysis to study regional climate variations of the United States, and identifying its applied limitations

Bosilovich, M G.↗

Standard Practices for Usage of Inductive Magnetic Field Probes with Application to Electric Propulsion Testing

Inductive magnetic field probes (also known as B-dot probes and sometimes as B-probes or magnetic probes) are useful for performing measurements in electric space thrusters and various plasma accelerator applications where a time-varying magnetic field is present. Magnetic field probes have proven to be a mainstay in diagnosing plasma thrusters where changes occur rapidly with respect to time, providing the means to measure the magnetic fields produced by time-varying currents and even an indirect measure of the plasma current density through the application of Ampère's law. Examples of applications where this measurement technique has been employed include pulsed plasma thrusters and quasi-steady magnetoplasmadynamic thrusters. The Electric Propulsion Technical Committee (EPTC) of the American Institute of Aeronautics and Astronautics (AIAA) was asked to assemble a Committee on Standards (CoS) for Electric Propulsion Testing. The assembled CoS was tasked with developing Standards and Recommended Practices for various diagnostic techniques used in the evaluation of plasma thrusters. These include measurements that can yield either global information related to a thruster and its performance or detailed, local data related to the specific physical processes occurring in the plasma. This paper presents a summary of the standard, describing the preferred methods for fabrication, calibration, and usage of inductive magnetic field probes for use in diagnosing plasma thrusters. Inductive magnetic field probes (also called B-dot probes throughout this document) are commonly used in electric propulsion (EP) research and testing to measure unsteady magnetic fields produced by time-varying currents. The B-dot probe is relatively simple in construction, and requires minimal cost, making it a low-cost technique that is readily accessible to most researchers. While relatively simple, the design of a B-dot probe is not trivial and there are many opportunities for errors in probe construction, calibration, and usage, and in the post-processing of data that is produced by the probe. There are typically several ways in which each of these steps can be approached, and different applications may require more or less vigorous attention to various issues.

Polzin, Kurt A.↗

Differential Motion Between Mediastinal Lymph Nodes and Primary Tumor in Radically Irradiated Lung Cancer Patients

Purpose/Objective: In patients with locally advanced lung cancer, planning target volume margins for mediastinal lymph nodes and tumor after a correction protocol based on bony anatomy registration typically range from 1 to 1.5 cm. Detailed information about lymph node motion variability and differential motion with the primary tumor, however, is lacking from large series. In this study, lymph node and tumor position variability were analyzed in detail and correlated to the main carina to evaluate possible margin reduction. Methods and Materials: Small gold fiducial markers (0.35 × 5 mm) were placed in the mediastinal lymph nodes of 51 patients with non-small cell lung cancer during routine diagnostic esophageal or bronchial endoscopic ultrasonography. Four-dimensional (4D) planning computed tomographic (CT) and daily 4D cone beam (CB) CT scans were acquired before and during radical radiation therapy (66 Gy in 24 fractions). Each CBCT was registered in 3-dimensions (bony anatomy) and 4D (tumor, marker, and carina) to the planning CT scan. Subsequently, systematic and random residual misalignments of the time-averaged lymph node and tumor position relative to the bony anatomy and carina were determined. Additionally, tumor and lymph node respiratory amplitude variability was quantified. Finally, required margins were quantified by use of a recipe for dual targets. Results: Relative to the bony anatomy, systematic and random errors ranged from 0.16 to 0.32 cm for the markers and from 0.15 to 0.33 cm for the tumor, but despite similar ranges there was limited correlation (0.17-0.71) owing to differential motion. A large variability in lymph node amplitude between patients was observed, with an average motion of 0.56 cm in the cranial-caudal direction. Margins could be reduced by 10% (left-right), 27% (cranial-caudal), and 10% (anteroposterior) for the lymph nodes and −2%, 15%, and 7% for the tumor if an online carina registration protocol replaced a protocol based on bony anatomy registration. Conclusions: Detailed analysis revealed considerable lymph node position variability, differential motion, and respiratory motion. Planning target volume margins can be reduced up to 27% in lung cancer patients when the carina registration replaces bony anatomy registration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

THE EVOLUTION OF THE STELLAR MASS FUNCTIONS OF STAR-FORMING AND QUIESCENT GALAXIES TO z = 4 FROM THE COSMOS/UltraVISTA SURVEY

We present measurements of the stellar mass functions (SMFs) of star-forming and quiescent galaxies to z = 4 using a sample of 95,675 K{sub s} -selected galaxies in the COSMOS/UltraVISTA field. The SMFs of the combined population are in good agreement with previous measurements and show that the stellar mass density of the universe was only 50%, 10%, and 1% of its current value at z ∼ 0.75, 2.0, and 3.5, respectively. The quiescent population drives most of the overall growth, with the stellar mass density of these galaxies increasing as ρ{sub star}∝(1 + z){sup –4.7±0.4} since z = 3.5, whereas the mass density of star-forming galaxies increases as ρ{sub star}∝(1 + z){sup –2.3±0.2}. At z > 2.5, star-forming galaxies dominate the total SMF at all stellar masses, although a non-zero population of quiescent galaxies persists to z = 4. Comparisons of the K{sub s} -selected star-forming galaxy SMFs with UV-selected SMFs at 2.5 < z < 4 show reasonable agreement and suggest that UV-selected samples are representative of the majority of the stellar mass density at z > 3.5. We estimate the average mass growth of individual galaxies by selecting galaxies at fixed cumulative number density. The average galaxy with log(M{sub star}/M{sub ☉}) = 11.5 at z = 0.3 has grown in mass by only 0.2 dex (0.3 dex) since z = 2.0 (3.5), whereas those with log(M{sub star}/M{sub ☉}) = 10.5 have grown by >1.0 dex since z = 2. At z < 2, the time derivatives of the mass growth are always larger for lower-mass galaxies, which demonstrates that the mass growth in galaxies since that redshift is mass-dependent and primarily bottom-up. Lastly, we examine potential sources of systematic uncertainties in the SMFs and find that those from photo-z templates, stellar population synthesis modeling, and the definition of quiescent galaxies dominate the total error budget in the SMFs.

79 ASTRONOMY AND ASTROPHYSICS↗

Helicopter approach capability using the differential Global Positioning System

The results of flight tests to determine the feasibility of using the Global Positioning System (GPS) in the differential mode (DGPS) to provide high accuracy, precision navigation and guidance for helicopter approaches to landing are presented. The airborne DGPS receiver and associated equipment is installed in a NASA UH-60 Black Hawk helicopter. The ground-based DGPS reference receiver is located at a surveyed test site and is equipped with a real-time VHF data link to transmit correction information to the airborne DGPS receiver. The corrected airborne DGPS information, together with the preset approach geometry, is used to calculate guidance commands which are sent to the aircraft's approach guidance instruments. The use of DGPS derived guidance for helicopter approaches to landing is evaluated by comparing the DGPS data with the laser tracker truth data. Both standard (3 degrees) and steep (6 degrees and 9 degrees) glidescope straight-in approaches were flown. DGPS positioning accuracy based on a time history analysis of the entire approach was 0.2 m (mean) +/- 1.8 m (2 sigma) laterally and -2.0 m (mean) +/- 3.5 m (2 sigma) vertically for 3 degree glidescope approaches, -0.1 m (mean) +/- 1.5 m (2 sigma) laterally and -1.1 m (mean) +/- 3.5 m (2 sigma) vertically for 6 degree glidescope approaches, and 0.2 m (mean) +/- 1.3 m (2 sigma) laterally and -1.0 m (mean) +/- 2.8 (2 sigma) vertically for 9 degree glidescope approaches. DGPS positioning accuracy at the 200 ft decision height on a standard 3 degree glidescope approach was 0.3 m (mean) +/- 1.5 m (2 sigma) laterally and -2.3 m (mean) +/- 1.6 m (2 sigma) vertically. These errors indicate that the helicopter position based on DGPS guidance satisfies the International Civil Aviation Organization Category 1 lateral and vertical accuracy requirements.

Kaufmann, David N.↗

Modifying the Human-Machine Interface Based on Quantitative Measurements of the Level of Awareness

This project got underway without funding approved during the summer of 1998. The initial project steps were to identify previously published work in the fields of error classification systems, physiological measurements of awareness, and related topics. This agenda was modified at the request of NASA Ames in August, 1998 to include supporting the new Cargo Air Association (CAA) evaluation of the Human Factors related to the ADS-B technology. Additional funding was promised to fully support both efforts. Work on library research ended in the late Fall, 1998 when the SJSU project directors were informed that NASA would not be adding to the initial funding of the research project as had been initially committed. However, NASA did provide additional funding for the CAA project activity. NASA elected to leave the research grant in place to provide a pathway for the CAA project funding to SJSU (San Jose State University) to support Dr. Freund's work on the CAA tasks. Dr. Knapp essentially terminated his involvement with the project at this time.

Freund, Louis E.↗

Evaluation of Markerless Motion Capture for Monitoring Sensorimotor Performance

BACKGROUND Astronauts returning from long-duration exposure to microgravity frequently exhibit alterations in sensorimotor function leading to postural imbalance, impaired locomotion, and operational challenges to manual control. Mission duration and individual responses often influence both the severity of performance decrements and the variability in adaptation timelines. Postflight disruptions during functional tasks are often detected through body-worn inertial measurement unit (IMU) devices. While IMU sensors are relatively compact, the long-term wear may lead to discomfort, displacement of the sensors on the body, and restrictions in movement or crew behavior. Although IMU data offers valuable insights from a research standpoint, interpreting changes in pre- and post-flight measures can be difficult for crew support personnel beyond the research domain, which can hinder the application for medical assessments and rehabilitation. Finally, the availability of inertial sensors in-flight is limited. There is a need for unobtrusive monitoring tools to improve our ability to monitor adaptation following gravitational transitions in various postflight evaluations and rehabilitation settings. Markerless motion capture (MMC) is an evolving unobtrusive technology that builds upon decades of research with marker-based motion capture systems to provide 3D human pose estimation from multiple synchronized 2D camera views using deep learning algorithms. Markerless technology can revolutionize how data is captured pre- and post-flight and potentially in-flight during intravehicular activity by enabling pose estimation of multiple crew members from onboard camera hardware. METHODS The following presents the initial evaluation of a state-of-the-art commercial-off-the-shelf MMC system, Theia Markerless, compared to IMU devices during various ground-based functional tasks and environmental conditions. The featured functional tasks include assessments from Human Research Program (HRP) funded studies such as Sensorimotor Standard Measures and Sensorimotor Assessments. Synchronous data collected using both motion capture and IMUs are analyzed for six male and female subjects of varying anthropometry. The analysis includes limited assessments of clothing, capture volume configurations, and the tool's sensitivity to detecting performance changes after a spaceflight analog centrifuge exposure. The development of visualization tools to enhance the application of the pose estimation output is also presented. RESULTS Initial results demonstrate comparable root mean square error (RMSE) to existing literature evaluating markerless and marker-based motion capture systems. Considering the relative functional range of motion of the cervical spine, normalized error values for the markerless system’s accuracy of the head was 0.032 in pitch, 0.025 in roll, and 0.018 in yaw plane of motion across a subset of functional tasks. The raw RMSE values were 3.49, 2.25, and 2.81 degrees respectively. For the torso, results suggest normalized errors of 0.469 in pitch, 0.191 in roll, and 0.307 in yaw planes of motion and raw RMSE values of 3.52, 1.53, and 3.07 degrees respectively. The data suggests the functional demands of a particular task influences the estimation accuracy of the MMC system where more dynamic motion and cases where subjects are not upright may introduce diminished tracking accuracy. DISCUSSION The following work lays the foundation for future implementations leveraging markerless motion capture to assess the time course of recovery and provide insight for rehabilitation protocols to enhance crew readiness for the resumption of daily activities. These tools offer effective methods for anonymizing sensitive crew data, facilitating numerous applications across research, medical, and rehabilitation groups. Collaborations with the Anthropometry and Biomechanics Facility will provide further comparisons of the Markerless system to a marker-based system. ACKNOWLEDGEMENT</ This work is supported by NASA’s Exploration Systems Development Mission Directorate Mars Campaign Office Crew Health Countermeasures.

Hannah M. Weiss↗

An assessment of atypical mesh topologies for low-Mach large-eddy simulation

An implicit, low-dissipation, low-Mach, variable density control volume finite element formulation is used to explore foundational understanding of numerical accuracy for large-eddy simulation applications on hybrid meshes. Detailed simulation comparisons are made between low-order hexahedral, tetrahedral, pyramid, and wedge/prism topologies against a third-order, unstructured hexahedral topology. Using smooth analytical and manufactured low-Mach solutions, design-order convergence is established for the hexahedral, tetrahedral, pyramid, and wedge element topologies using a new open boundary condition based on energy-stable methodologies previously deployed within a finite-difference context. A wide range of simulations demonstrate that low-order hexahedral- and wedge-based element topologies behave nearly identically in both computed numerical errors and overall simulation timings. Moreover, low-order tetrahedral and pyramid element topologies also display nearly the same numerical characteristics. Although the superiority of the hexahedral-based topology is clearly demonstrated for trivial laminar, principally-aligned flows, e.g., a 1x2x10 channel flow with specified pressure drop, this advantage is reduced for non-aligned, turbulent flows including the Taylor–Green Vortex, turbulent plane channel flow ( Re τ 395), and buoyant flow past a heated cylinder. With the order of accuracy demonstrated for both homogenous and hybrid meshes, it is shown that solution verification for the selected complex flows can be established for all topology types. Although the number of elements in a mesh of like spacing comprised of tetrahedral, wedge, or pyramid elements increases as compared to the hexahedral counterpart, for wall-resolved large-eddy simulation, the increased assembly and residual evaluation computational time for non-hexahedral is offset by more efficient linear solver times. Lastly, most simulation results indicate that modest polynomial promotion provides a significant increase in solution accuracy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Software-controlled, highly automated intrafraction prostate motion correction with intrafraction stereographic targeting: System description and clinical results

Purpose: A new system for software-controlled, highly automated correction of intrafraction prostate motion,'' intrafraction stereographic targeting'' (iSGT), is described and evaluated. Methods: At our institute, daily prostate positioning is routinely performed at the start of treatment beam using stereographic targeting (SGT). iSGT was implemented by extension of the SGT software to facilitate fast and accurate intrafraction motion corrections with minimal user interaction. iSGT entails megavoltage (MV) image acquisitions with the first segment of selected IMRT beams, automatic registration of implanted markers, followed by remote couch repositioning to correct for intrafraction motion above a predefined threshold, prior to delivery of the remaining segments. For a group of 120 patients, iSGT with corrections for two nearly lateral beams was evaluated in terms of workload and impact on effective intrafraction displacements in the sagittal plane. Results: SDs of systematic ({Sigma}) and random ({sigma}) displacements relative to the planning CT measured directly after initial SGT setup correction were <0.5 and <0.8 mm, respectively. Without iSGT corrections, effective {Sigma} and {sigma} for the 11-min treatments would increase to {Sigma}{sub eff} < 1.1 mm and {sigma}{sub eff} < 1.2 mm. With the iSGT procedure with an action level of 4 mm, effective positioning errors were reduced to {Sigma}{sub eff} < 0.8 mm and {sigma}{sub eff} < 1.0 mm, with 23.1% of all fractions requiring a correction. Computer simulations demonstrated that with an action level of 2 mm, the errors would have been reduced to {Sigma}{sub eff} < 0.6 mm and {sigma}{sub eff} < 0.7 mm, requiring corrections in 82.4% of the fractions. Because iSGT is highly automated, the extra time added by iSGT is <30 s if a correction is required. Conclusions: Without increasing imaging dose, iSGT successfully reduces intrafraction prostate motion with minimal workload and increase in fraction time. An action level of 2 mm is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

RACE and Calculations of Three-dimensional Distributed Cavity Phase Shifts

The design for RACE, a Rb-clock flight experiment for the ISS, is described. The cold collision shift and multiple launching (juggling) have important implications for the design and the resulting clock accuracy and stability. We present and discuss the double clock design for RACE. This design reduces the noise contributions of the local oscillator and simplifies and enhances an accuracy evaluation of the clock. As we try to push beyond the current accuracies of clocks, new systematic errors become important. The best fountain clocks are using cylindrical TE(sub 011) microwave cavities. We recently pointed out that many atoms pass through a node of the standing wave microwave field in these cavities. Previous studies have shown potentially large frequency shifts for atoms passing through nodes in a TE(sub 013) cavity. The shift occurs because there is a small traveling wave component due to the absorption of the copper cavity walls. The small traveling wave component leads to position dependent phase shifts. To study these effects, we perform Finite Element calculations. Three-dimensional Finite Element calculations require significant computer resources. Here we show that the cylindrical boundary condition can be Fourier decomposed to a short series of two-dimensional problems. This dramatically reduces the time and memory required and we obtain (3D) phase distributions for a variety of cavities. With these results, we will be able to analyze this frequency shift in fountain and future space clocks.

Li, Ruoxin↗

Using Apex To Construct CPM-GOMS Models

process for automatically generating computational models of human/computer interactions as well as graphical and textual representations of the models has been built on the conceptual foundation of a method known in the art as CPM-GOMS. This method is so named because it combines (1) the task decomposition of analysis according to an underlying method known in the art as the goals, operators, methods, and selection (GOMS) method with (2) a model of human resource usage at the level of cognitive, perceptual, and motor (CPM) operations. CPM-GOMS models have made accurate predictions about behaviors of skilled computer users in routine tasks, but heretofore, such models have been generated in a tedious, error-prone manual process. In the present process, CPM-GOMS models are generated automatically from a hierarchical task decomposition expressed by use of a computer program, known as Apex, designed previously to be used to model human behavior in complex, dynamic tasks. An inherent capability of Apex for scheduling of resources automates the difficult task of interleaving the cognitive, perceptual, and motor resources that underlie common task operators (e.g., move and click mouse). The user interface of Apex automatically generates Program Evaluation Review Technique (PERT) charts, which enable modelers to visualize the complex parallel behavior represented by a model. Because interleaving and the generation of displays to aid visualization are automated, it is now feasible to construct arbitrarily long sequences of behaviors. The process was tested by using Apex to create a CPM-GOMS model of a relatively simple human/computer-interaction task and comparing the time predictions of the model and measurements of the times taken by human users in performing the various steps of the task. The task was to withdraw $80 in cash from an automated teller machine (ATM). For the test, a Visual Basic mockup of an ATM was created, with a provision for input from (and measurement of the performance of) the user via a mouse. The times predicted by the automatically generated model turned out to approximate the measured times fairly well (see figure). While these results are promising, there is need for further development of the process. Moreover, it will also be necessary to test other, more complex models: The actions required of the user in the ATM task are too sequential to involve substantial parallelism and interleaving and, hence, do not serve as an adequate test of the unique strength of CPM-GOMS models to accommodate parallelism and interleaving.

John, Bonnie↗

Validation, Comparison, and Integration of GOCI, AHI, MODIS, MISR, and VIIRS Aerosol Optical Depth Over East Asia During the 2016 KORUS-AQ Campaign

Recently launched multichannel geostationary Earth orbit (GEO) satellite sensors, such as the Geostationary Ocean Color Imager (GOCI) and the Advanced Himawari Imager (AHI), provide aerosol products over East Asia with high accuracy, which enables the monitoring of rapid diurnal variations and the transboundary transport of aerosols. Most aerosol studies to date have used low Earth orbit (LEO) satellite sensors, such as the Moderate Resolution Imaging Spectroradiometer (MODIS) and the Multi-angle Imaging Spectroradiometer (MISR), with a maximum of one or two overpass daylight times per day from midlatitudes to low latitudes. Thus, the demand for new GEO observations with high temporal resolution and improved accuracy has been significant. In this study the latest versions of aerosol optical depth (AOD) products from three LEO sensors – MODIS (Dark Target, Deep Blue, and MAIAC), MISR, and the Visible/Infrared Imager Radiometer Suite (VIIRS), along with two GEO sensors (GOCI and AHI), are validated, compared, and integrated for a period during the Korea–United States Air Quality Study (KORUS-AQ) field campaign from 1 May to 12 June 2016 over East Asia. The AOD products analyzed here generally have high accuracy with high R (0.84–0.93) and low RMSE (0.12–0.17), but their error characteristics differ according to the use of several different surface-reflectance estimation methods. High-accuracy near-real-time GOCI and AHI measurements facilitate the detection of rapid AOD changes, such as smoke aerosol transport from Russia to Japan on 18–21 May 2016, heavy pollution transport from China to the Korean Peninsula on 25 May 2016, and local emission transport from the Seoul Metropolitan Area to the Yellow Sea in South Korea on 5 June 2016. These high-temporal-resolution GEO measurements result in more representative daily AOD values and make a greater contribution to a combined daily AOD product assembled by median value selection with a 0.5∘×0.5∘ grid resolution. The combined AOD is spatially continuous and has a greater number of pixels with high accuracy (fraction within expected error range of 0.61) than individual products. This study characterizes aerosol measurements from LEO and GEO satellites currently in operation over East Asia, and the results presented here can be used to evaluate satellite measurement bias and air quality models.

Myungje Choi↗

A method to improve accuracy and precision of water surface identification for photon depth dose measurements

The objective of this study is to present a method to reduce the setup error inherent in clinical depth dose measurements and, in doing so, to improve entrance dosimetry measurement reliability. Ionization chamber (IC) depth dose measurements are acquired with the depth scan extended into the air above the water surface. An inflection region is obtained in each resulting percent depth ionization (PDI) curve that can be matched against other measurements or to an inflection region obtained from an analogous Monte Carlo (MC) simulation. Measurements are made with various field sizes for the 6 and 18 MV photon beams, with and without a Pb foil in the beam, to determine the sensitivity of the dose inflection region to the beam conditions. The offset between reference and test data set inflection regions is quantified using two separate methods. When comparing sets of measured data, maxima in the second derivative of ionization are compared. When comparing measured data to MC simulation, the offset that minimizes the sum of squared differences between the reference and test curves in the ionization inflection region is found. These methods can be used to quantify the offset between an initial setup (test) position and the true surface (reference) position. The ionization inflection location is found to be insensitive to changes in field size, electron contamination, and beam energy. Data from a single reference condition should be sufficient to identify the surface location. The method of determining IC offsets is general and should be applicable to any IC and other radiation sources. The measurement method could reduce the time and effort required in the initial IC setup at a water surface as setup errors can be corrected offline. Given a reliable set of reference data to compare with, this method could increase the ability of quality assurance (QA) measurements to detect discrepancies in beam output as opposed to discrepancies in IC localization. Application of the measurement method standardizes the procedure for localizing cylindrical ICs at a water surface and thereby improves the reliability of measurements taken with these devices at all depths.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗