Correction method for in-air output ratio for output variations occurring with changes in backscattered radiation

Purpose: The in-air output ratio (S{sub c}) for a rectangular field is usually obtained using an equivalent square field formula. However, it is well-known that S{sub c} obtained using an equivalent square field formula differs slightly from the measured S{sub c}. Though several correction methods have been suggested for the monitor-backscatter effect, the authors propose a more simple correction method for a rectangular field. Methods: For rectangular fields and equivalent square fields, the authors assumed that the output variation was the product of six output variations for each backscattering area at the top of the collimator jaws, and the correction factor was the ratio of the output variation for a rectangular field to the output variation for an equivalent square field. The output variation was measured by using a telescope measurement. Results: The differences between the measured and corrected S{sub c} ranged from -0.20% to 0.28% for symmetric rectangular fields by applying the correction factor to S{sub c} obtained using an equivalent square field formula. This correction method is also available for asymmetric rectangular fields. Conclusions: The authors propose a method to correct S{sub c} obtained using an equivalent square field formula, and a method to obtain the output variation for a field defined by collimator jaws.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Trajectory optimization for the Atlas/Centaur launch vehicle

A method for finding solutions to complex trajectory optimization problems with detailed hardware and launch vehicle constraints is presented. The trajectory optimization problem is formulated as a constrained function minimization problem by modeling the control by a function of a finite number of parameters. Although any parametric control model may be selected, the natural choice of parameters is the actual parameters of the parametric guidance equations flown on the flight digital computer. A variation of the method of multipliers is presented for performing the constrained function minimization. A functional is proposed that allows incorporation of state variable inequality constraints. Finally, optimization of the HEAO-A direct-ascent trajectory is discussed. The HEAO-A mission demonstrates profile optimization to meet range safety, tracking, heating, structural integrity, and attitude rate constraints.

Brusch, R. G.↗

SU-F-303-11: Implementation and Applications of Rapid, SIFT-Based Cine MR Image Binning and Region Tracking

Purpose: To develop a novel and rapid, SIFT-based algorithm for assessing feature motion on cine MR images acquired during MRI-guided radiotherapy treatments. In particular, we apply SIFT descriptors toward both partitioning cine images into respiratory states and tracking regions across frames. Methods: Among a training set of images acquired during a fraction, we densely assign SIFT descriptors to pixels within the images. We cluster these descriptors across all frames in order to produce a dictionary of trackable features. Associating the best-matching descriptors at every frame among the training images to these features, we construct motion traces for the features. We use these traces to define respiratory bins for sorting images in order to facilitate robust pixel-by-pixel tracking. Instead of applying conventional methods for identifying pixel correspondences across frames we utilize a recently-developed algorithm that derives correspondences via a matching objective for SIFT descriptors. Results: We apply these methods to a collection of lung, abdominal, and breast patients. We evaluate the procedure for respiratory binning using target sites exhibiting high-amplitude motion among 20 lung and abdominal patients. In particular, we investigate whether these methods yield minimal variation between images within a bin by perturbing the resulting image distributions among bins. Moreover, we compare the motion between averaged images across respiratory states to 4DCT data for these patients. We evaluate the algorithm for obtaining pixel correspondences between frames by tracking contours among a set of breast patients. As an initial case, we track easily-identifiable edges of lumpectomy cavities that show minimal motion over treatment. Conclusions: These SIFT-based methods reliably extract motion information from cine MR images acquired during patient treatments. While we performed our analysis retrospectively, the algorithm lends itself to prospective motion assessment. Applications of these methods include motion assessment, identifying treatment windows for gating, and determining optimal margins for treatment.

60 APPLIED LIFE SCIENCES↗

“Inverting” X-ray Absorption Spectra of Catalysts by Machine Learning in Search for Activity Descriptors

The rapid growth of methods emerging in the past decade for synthesis of “designer” catalysts—ranging from the size and shape-selected nanoparticles to mass-selected clusters, to precisely engineered bimetallic surfaces, to single site and pair site catalysts—has opened opportunities for tailoring the catalyst structure for the desired activity and selectivity. It has also sharpened the need for developing approaches to the operando characterization, ones that identify the catalytic active sites and follow their evolutions in reaction conditions. Commonly used methods for determination of the activity descriptors in the nanocatalysts, based on the correlation between the changes in catalyst performance and evolution of its structural and electronic properties, are hampered by the paucity of experimental techniques that can detect such properties with high accuracy and in reaction conditions. Out of many such techniques, X-ray absorption spectroscopy (XAS) stands out as an element-specific method that is very sensitive to the local geometric and electronic properties of the metal atoms and their surroundings and, therefore, is able to track catalyst structure modifications in operando conditions. Despite the vast amount of structure-specific information (such as, e.g., the charge states and radial distribution function of neighbors of selected atomic species) stored in the XAS data of catalysts, extracting it from the spectra is challenging, especially in the conditions of low metal weight loading, nanoscale dimensions, heterogeneous size and composition distributions, and harsh reaction environment. In this Perspective, we discuss the recent developments in XAS data analysis achieved by employing supervised and unsupervised machine learning (ML) methods for structural characterization of catalysts. By benefiting from the sensitivity of ML methods to subtle variations in experimental data, a previously “hidden” relationship between the X-ray absorption spectrum and descriptors of material’s structure and/or composition can be found, as illustrated on representative examples of mono-, hetero-, and nonmetallic catalysts. In the case of supervised ML, the experimental spectra can be rapidly “inverted”, and the structure of the catalyst can be tracked in real time and in reaction conditions. Finally, emerging opportunities for catalysis research that the ML methods enable, such as high-throughput data analysis, and their applications to other experimental probes of catalyst structure are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-Linear Structural Dynamics Characterization using a Scanning Laser Vibrometer

This paper presents the use of a scanning laser vibrometer and a signal decomposition method to characterize non-linear dynamics of highly flexible structures. A Polytec PI PSV-200 scanning laser vibrometer is used to measure transverse velocities of points on a structure subjected to a harmonic excitation. Velocity profiles at different times are constructed using the measured velocities, and then each velocity profile is decomposed using the first four linear mode shapes and a least-squares curve-fitting method. From the variations of the obtained modal \ielocities with time we search for possible non-linear phenomena. A cantilevered titanium alloy beam subjected to harmonic base-excitations around the second. third, and fourth natural frequencies are examined in detail. Influences of the fixture mass. gravity. mass centers of mode shapes. and non-linearities are evaluated. Geometrically exact equations governing the planar, harmonic large-amplitude vibrations of beams are solved for operational deflection shapes using the multiple shooting method. Experimental results show the existence of 1:3 and 1:2:3 external and internal resonances. energy transfer from high-frequency modes to the first mode. and amplitude- and phase- modulation among several modes. Moreover, the existence of non-linear normal modes is found to be questionable.

Pai, P. F.↗

Spherical powders: Control over the size and morphology of powders for additive manufacturing and enriched stable isotope nuclear targets

Metal powders are a fundamental starting point for fabricating many types of nuclear targets. Elemental powder properties can differ drastically between batches, even when using the same method. Therefore, the variation in morphology and the size of metal powders can cause variable quality and produce inconsistent results with what are otherwise proven target manufacturing techniques. Additive manufacturing has additional requirements for higher quality and more uniform feedstock. The production of spheroidized powders with uniform, reproducible properties and a narrow size distribution represents unexplored opportunities for experiments. These opportunities include experimenting with solid metals that can now flow like liquids, new options for powder handling and dispensing, and new target fabrication methods using additive manufacturing. The Stable Isotope Materials and Chemistry Group at Oak Ridge National Laboratory obtained an AMAZEMET rePowder ultrasonic metal atomization tool for creating limited batches of fully dense, free flowing, spherical powders with a narrow size distribution of extremely rare materials. Early results are presented with materials that were produced. The team explores the anticipated limits of this instrument with extremely rare materials (e.g., enriched stable isotopes) and highlights research into new fabrication techniques that provide additional options benefitting the international nuclear target community.

Zach, Mike↗

Microstructure of vapor deposited coatings on curved substrates

Thermal barrier coating systems consisting of a metallic bond coat and ceramic over layer are widely used to extend the life of gas turbine engine components. They are applied using either high-vacuum physical vapor deposition techniques in which vapor atoms rarely experience scattering collisions during propagation to a substrate, or by gas jet assisted (low-vacuum) vapor deposition techniques that utilize scattering from streamlines to enable non-line-of-sight deposition. Both approaches require substrate motion to coat a substrate of complex shape. Here, direct simulation Monte Carlo and kinetic Monte Carlo simulation methods are combined to simulate the deposition of a nickel coating over the concave and convex surfaces of a model airfoil, and the simulation results are compared with those from experimental depositions. The simulation method successfully predicted variations in coating thickness, columnar growth angle, and porosity during both stationary and substrate rotated deposition. It was then used to investigate a wide range of vapor deposition conditions spanning high-vacuum physical vapor deposition to low-vacuum gas jet assisted vapor deposition. The average coating thickness was found to increase initially with gas pressure reaching a maximum at a chamber pressure of 8–10 Pa, but the best coating thickness uniformity was achieved under high vacuum deposition conditions. However, high vacuum conditions increased the variation in the coatings pore volume fraction over the surface of the airfoil. The simulation approach was combined with an optimization algorithm and used to investigate novel deposition concepts to tailor the local coating thickness.

42 ENGINEERING↗

SU-D-206-03: Segmentation Assisted Fast Iterative Reconstruction Method for Cone-Beam CT

Purpose: Total Variation (TV) based iterative reconstruction (IR) methods enable accurate CT image reconstruction from low-dose measurements with sparse projection acquisition, due to the sparsifiable feature of most CT images using gradient operator. However, conventional solutions require large amount of iterations to generate a decent reconstructed image. One major reason is that the expected piecewise constant property is not taken into consideration at the optimization starting point. In this work, we propose an iterative reconstruction method for cone-beam CT (CBCT) using image segmentation to guide the optimization path more efficiently on the regularization term at the beginning of the optimization trajectory. Methods: Our method applies general knowledge that one tissue component in the CT image contains relatively uniform distribution of CT number. This general knowledge is incorporated into the proposed reconstruction using image segmentation technique to generate the piecewise constant template on the first-pass low-quality CT image reconstructed using analytical algorithm. The template image is applied as an initial value into the optimization process. Results: The proposed method is evaluated on the Shepp-Logan phantom of low and high noise levels, and a head patient. The number of iterations is reduced by overall 40%. Moreover, our proposed method tends to generate a smoother reconstructed image with the same TV value. Conclusion: We propose a computationally efficient iterative reconstruction method for CBCT imaging. Our method achieves a better optimization trajectory and a faster convergence behavior. It does not rely on prior information and can be readily incorporated into existing iterative reconstruction framework. Our method is thus practical and attractive as a general solution to CBCT iterative reconstruction. This work is supported by the Zhejiang Provincial Natural Science Foundation of China (Grant No. LR16F010001), National High-tech R&D Program for Young Scientists by the Ministry of Science and Technology of China (Grant No. 2015AA020917).

60 APPLIED LIFE SCIENCES↗

Surface photometry of spiral galaxies. I - Theoretical color variation and surface brightness across spiral arms

A method for the construction of color variations and surface brightness across a galactic spiral arm, using the concepts and results of the density-wave theory, is developed. The color variation measured by the index Q varies with the ratio of the light of young stars to that of the old stars, the initial mass function, and the pattern speed. The fact that the variation of brightness and color across a spiral arm is relatively smooth and symmetrical and not sharp as in the galactic shock picture is due to the smearing-out effects of star formation inside a cloud in the regions behind the galactic shock, and the tendency of new stars to fall back to small galactocentric distances after their formation because of their lower angular velocity at birth. Both effects arise naturally in the context of the density-wave theory.

Yuan, C.↗

Localization of deformable tumors from short-arc projections using Bayesian estimation

Purpose: The authors present a stochastic framework for radiotherapy patient positioning directly utilizing radiographic projections. This framework is developed to be robust against anatomical nonrigid deformations and to cope with challenging imaging scenarios, involving only a few cone beam CT projections from short arcs. Methods: Specifically, a Bayesian estimator (BE) is explicitly derived for the given scanning geometry. This estimator is compared to reference methods such as chamfer matching (CM) and the minimization of the median absolute error adapted as tools of robust image processing and statistics. In order to show the performance of the stochastic short-arc patient positioning method, a CIRS IMRT thorax phantom study is presented with movable markers and the utilization of an Elekta Synergy{sup Registered-Sign} XVI system. Furthermore, a clinical prostate CBCT scan of a Varian{sup Registered-Sign} On-Board Imager{sup Registered-Sign} system is utilized to investigate the robustness of the method for large variations of image quality (anterior-posterior vs lateral views). Results: The results show that the BE shifts reduce the initial setup error of up to 3 cm down to 3 mm at maximum for an imaging arc as short as 10 Degree-Sign while CM achieves residual errors of 7 mm at maximum only for arcs longer than 40 Degree-Sign . Furthermore, the BE can compensate robustly for low image qualities using several low quality projections simultaneously. Conclusions: In conclusion, an estimation method for marker-based patient positioning for short imaging arcs is presented and shown to be robust and accurate for deformable anatomies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A finite element simulation of sound attenuation in a finite duct with a peripherally variable liner

Using multimodal analysis, a variational finite element method is presented for analyzing sound attenuation in a three-dimensional finite duct with a peripherally variable liner in the absence of flow. A rectangular element, with cubic shaped functions, is employed. Once a small portion of a peripheral liner is removed, the attenuation rate near the frequency where maximum attenuation occurs drops significantly. The positioning of the liner segments affects the attenuation characteristics of the liner. Effects of the duct termination are important in the low frequency ranges. The main effect of peripheral variation of the liner is a broadening of the attenuation characteristics in the midfrequency range. Because of matrix size limitations of the presently available computer program, the eigenvalue equations should be solved out of core in order to handle realistic sources.

Watson, W. R.↗

Error Bounds for Dynamical Spectral Estimation

Dynamical spectral estimation is a well-established numerical approach for estimating eigenvalues and eigenfunctions of the Markov transition operator from trajectory data. Although the approach has been widely applied in biomolecular simulations, its error properties remain poorly understood. Here we analyze the error of a dynamical spectral estimation method called “the variational approach to conformational dynamics" (VAC). We bound the approximation error and estimation error for VAC estimates. Our analysis establishes VAC's convergence properties and suggests new strategies for tuning VAC to improve accuracy.

97 MATHEMATICS AND COMPUTING↗

Solution of coupled and singular perturbation methods using duality theory.

Dual variational techniques developed by Chan and Leininger (1972) are summarized, and duality theory in the form of the Complementary Variational Principle is employed to provide a suboptimal measure for the singular and epsilon-coupled perturbation methods proposed by Kokotovic and Cruz. The suboptimal measure is independent of any a priori knowledge of the optimal solution, thereby providing an absolute estimate of the performance loss rather than an estimate relative to the unknown optimal solution.

Chan, W. L.↗

Two-dimensional solitons in media with stripe-shaped nonlinearity modulation

We introduce a model of media with the cubic attractive nonlinearity concentrated along a single or double stripe in the two-dimensional (2D) plane. The model can be realized in terms of nonlinear optics (in the spatial and temporal domains alike) and BEC. It is known from recent works that search for stable 2D solitons in models with a spatially localized self-attractive nonlinearity is a challenging problem. We make use of the variational approximation (VA) and numerical methods to investigate conditions for the existence and stability of solitons in the present setting. The result crucially depends on the transverse shape of the stripe: while the rectangular profile supports stable 2D solitons, its smooth Gaussian-shaped counterpart makes all the solitons unstable. This difference is explained, in particular, by the VA. The double stripe with the rectangular profile admits stable solitons of three distinct types: symmetric and asymmetric ones with a single-peak, and double-peak symmetric solitons. The shape and stability of the single-peak solitons of either type are accurately predicted by the VA. Collisions between identical stable solitons are briefly considered too, by means of direct simulations. Depending on the collision velocity, we observe excitation of intrinsic oscillations of the solitons, or their decay, or the collapse (catastrophic self-focusing).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reliability, stability during long-term storage, and intra-individual variation of circulating levels of osteopontin, osteoprotegerin, vascular endothelial growth factor-A, and interleukin-17A

Background: Studies in many populations have reported associations between circulating cytokine levels and various physiological or pathological conditions. However, the reliability of cytokine measurements in population studies, which measure cytokines in multiple assays over a prolonged period, has not been adequately examined; nor has stability during sample storage or intra-individual variation been assessed. Methods: We assessed (1) analytical reliability in short- and long-term repeated measurements; (2) stability and analytical reliability during long-term sample storage, and (3) variability within individuals over seasons, of four cytokines—osteopontin (OPN), osteoprotegerin (OPG), vascular endothelial growth factor-A (VEGF-A), and interleukin-17A (IL-17A). Measurements in plasma or serum samples were made with commercial kits according to standard procedures. Estimation was performed by fitting a random or mixed effects linear model on the log scale. Results: In repeated assays over a short period, OPN, OPG, and VEGF-A had acceptable reliability, with intra- and inter-assay coefficients of variation (CV) less than 0.11. Reliability of IL-17A was poor, with inter- and intra-assay CV 0.85 and 0.43, respectively. During long-term storage, OPG significantly decayed (-33% per year; 95% confidence interval [-54, -3.7]), but not OPN or VEGF-A (-0.3% or -6.3% per year, respectively). Intra- and inter-assay CV over a long period were comparable to that in a short period except for a slight increase in inter-assay CV of VEGF-A. Within-individual variation was small for OPN and VEGF-A, with intra-class correlations (ICC) 0.68 and 0.83, respectively, but large for OPG (ICC 0.11). Conclusions: We conclude that OPN and VEGF-A can be reliably measured in a large population, that IL-17A is suitable only for small experiments, and that OPG should be assessed with caution due to degradation during storage and intra-individual variation. The overall results of our study illustrate the need for validation under relevant conditions when measuring circulating cytokines in population studies.

60 APPLIED LIFE SCIENCES↗

Effects of Eye Measures on Human Controller Remnant and Control Behavior

The aim of the current research was to investigate the possible relation between changes in eye activity parameters, variations in human remnant at the perceptual level and changes in human operator model parameters. Fourteen subjects performed a pitch tracking task, in which the display brightness was varied by changing the background color around a simplified primary flight display, in order to create a controlled, quasilinear change in the pupil diameter through the pupillary light reflex. Pupil diameter, blink, eye opening, and opening and closing amplitudes and speeds were recorded using an eye tracker. Participants controlled single integrator-like and double integrator-like dynamics. The variation in pupil diameter did not introduce significant differences in neither remnant characteristics nor the human operator model parameters. An interesting effect occurred in the human controller’s time delay for the single integrator task, where the time delay was significantly higher for the darkest brightness compared to the other levels of brightness. This effect was not observed for the double integrator dynamics. Data suggested that the more difficult controlled dynamics induced a squinting effect, visible in smaller eye opening, and smaller eye opening and closing amplitudes. These results suggest that performance, and control behavior are invariant to the display brightness. Moreover, monitoring changes in the eye activity could represent a method of predicting variations in human remnant characteristics and human controller model parameters, introduced by task difficulty.

Eye tracking↗

TU-F-CAMPUS-I-02: Validation of a CT X-Ray Source Characterization Technique for Dose Computation Using An Anthropomorphic Thorax Phantom

Purpose: To experimentally validate a rotational kV x-ray source characterization technique by computing CT dose in an anthropomorphic thorax phantom using an in-house dose computation algorithm (kVDoseCalc). Methods: The lateral variation in incident energy spectra of a GE Optima big bore CT scanner was found by measuring the HVL along the internal, full bow-tie filter axis. The HVL and kVp were used to generate the x-ray spectra using Spektr software, while beam fluence was derived by dividing the integral product of the spectra and in-air mass-energy absorption coefficients by in-air dose measurements along the bow-tie filter axis. Beams produced by the GE Optima scanner were modeled at 80 and 140 kVp tube settings. kVDoseCalc calculates dose by solving the linear Boltzmann transport equation using a combination of deterministic and stochastic methods. Relative doses in an anthropomorphic thorax phantom (E2E SBRT Phantom) irradiated by the GE Optima scanner were measured using a (0.015 cc) PTW Freiburg ionization chamber, and compared to computations from kVDoseCalc. Results: The agreement in relative dose between dose computation and measurement for points of interest (POIs) within the primary path of the beam was within experimental uncertainty for both energies, however points outside the primary beam were not. The average absolute percent difference for POIs within the primary path of the beam was 1.37% and 5.16% for 80 and 140 kVp, respectively. The minimum and maximum absolute percent difference for both energies and all POIs within the primary path of the beam was 0.151% and 6.41%, respectively. Conclusion: The CT x-ray source characterization technique based on HVL measurements and kVp can be used to accurately compute CT dose in an anthropomorphic thorax phantom.

60 APPLIED LIFE SCIENCES↗

Piezoelectric response and failure behavior of cement paste under external loading

We study the elastic behavior and rupture mechanism of Calcium Silicate Hydrates (C-S-H) in response to tensile loading. For the three tensile axes, initial defects are spotted in the interlayer regions. However, the crack propagation is rather different depending on the axis of tensile. The cup-and-cone failure surface shows the ductile feature of C-S-H in the x and y directions; while the devastating rupture mode confirms the brittle feature of C-S-H in the z direction. Piezoelectricity was investigated using the charge fluctuation method. The polarization variation in response to small strain was also investigated and piezoelectric coefficients were derived. Furthermore, dependence of elastic and piezoelectric properties over external pressure was analyzed. Results reveal an improvement of the mechanical properties and the ultimate strength especially in the z direction; whereas the non-piezoelectricity remains unchanged despite the rearrangement of atoms induced by the external applied pressure.