Search NASA⌕ Search

SEARCH · Search NASA

Results for “verification study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

A Summary of the Development and Validation of the Scale for Habitat Usability (SHU)

Usability is an important concept to consider when designing space habitats/vehicles. In addition to objective outcomes (success rate, net habitable volume etc.), collecting users’ subjective judgments via comments and questionnaires can provide valuable data for evaluating conceptual designs, identifying potential layout issues, improving concept of operations, substantiating design changes, or selecting between competing mockups. Historically at NASA, there has been no “gold standard” questionnaire for capturing users’ subjective viewpoint regarding habitat design. To address this gap a Human Research Program (HRP) study was conducted to create a new measurement tool: the Scale for Habitat Usability (SHU).

Usability↗

Linear models to perform treaty verification tasks for enhanced information security

Linear mathematical models were applied to binary-discrimination tasks relevant to arms control verification measurements in which a host party wishes to convince a monitoring party that an item is or is not treaty accountable. These models process data in list-mode format and can compensate for the presence of variability in the source, such as uncertain object orientation and location. The Hotelling observer applies an optimal set of weights to binned detector data, yielding a test statistic that is thresholded to make a decision. The channelized Hotelling observer applies a channelizing matrix to the vectorized data, resulting in a lower dimensional vector available to the monitor to make decisions. We demonstrate how incorporating additional terms in this channelizing-matrix optimization offers benefits for treaty verification. We present two methods to increase shared information and trust between the host and monitor. The first method penalizes individual channel performance in order to maximize the information available to the monitor while maintaining optimal performance. Second, we present a method that penalizes predefined sensitive information while maintaining the capability to discriminate between binary choices. Data used in this study was generated using Monte Carlo simulations for fission neutrons, accomplished with the GEANT4 toolkit. Custom models for plutonium inspection objects were measured in simulation by a radiation imaging system. Model performance was evaluated and presented using the area under the receiver operating characteristic curve.

97 MATHEMATICS AND COMPUTING↗

A finite-element-based perturbation model for the rotordynamic analysis of shrouded pump impellers: Part 1: Model development and applications

This study concerns the rotor dynamic characteristics of fluid-encompassed rotors, with special emphasis on shrouded pump impellers. The core of the study is a versatile and categorically new finite-element-based perturbation model, which is based on a rigorous flow analysis and what we have generically termed the 'virtually' deformable finite-element approach. The model is first applied to the case of a smooth annular seal for verification purposes. The rotor excitation components, in this sample problem, give rise to a purely cylindrical, purely conical, and a simultaneous cylindrical/conical rotor whirl around the housing centerline. In all cases, the computed results are compared to existing experimental and analytical data involving the same seal geometry and operating conditions. Next, two labyrinth-seal configurations, which share the same tooth-to-tooth chamber geometry but differ in the total number of chambers, were investigated. The results, in this case, are compared to experimental measurements for both seal configurations. The focus is finally shifted to the shrouded-impeller problem, where the stability effects of the leakage flow in the shroud-to-housing secondary passage are investigated. To this end, the computational model is applied to a typical shrouded-impeller pump stage, fabricated and rotor dynamically tested by Sulzer Bros., and the results compared to those of a simplified 'bulk-flow' analysis and Sulzer Bros.' test data. In addition to assessing the computed rotor dynamic coefficients, the shrouded-impeller study also covers a controversial topic, namely that of the leakage-passage inlet swirl, which was previously cited as the origin of highly unconventional (resonance-like) trends of the fluid-exerted forces. In order to validate this claim, a 'microscopic' study of the fluid/shroud interaction mechanism is conducted, with the focus being on the structure of the perturbed flow field associated with the impeller whirl. The conclusions of this study were solidified by the outcome of a numerical-certainty exercise, where the grid dependency of the numerical results is objectively examined. The final phase of the shrouded-impeller investigation involves the validation of a built-in assumption, in all other perturbation models, whereby single-harmonic tangential distributions of all the flow thermophysical properties are imposed. The last phase of the investigation course is aimed at verifying the fine details of the perturbed flow field in light of recent set of detailed LDA measurements in a smooth annular seal. Grid dependency of the fluid-induced forces is also investigated, and specific recommendations are made.

Baskharone, Erian A.↗

Surface and superficial dose dosimetric verification for postmastectomy radiotherapy

In patients given postmastectomy radiotherapy (PMRT), the chest wall is a very thin layer of soft tissue with a low-density lung tissue behind. Chest wall treated in this situation with a high-energy photon beam presents a high dosimetric uncertainty region for both calculation and measurement. The purpose of this study was to measure and to evaluate the surface and superficial doses for patients requiring PMRT with different treatment techniques. An elliptic cylinder cork and superflab boluses were used to simulate the lung and the chest wall, respectively. Sets of computed tomography (CT) images with different chest wall thicknesses were acquired for the study phantom. Hypothetical clinical target volumes (CTVs) were outlined and modified to fit a margin of 1-3 mm, depending on the chest wall thickness, away from the surface for the sets of CT images. The planning target volume (PTV) was initially created by expanding an isotropic 3-mm margin from the CTV, and then a margin of 3 mm was shrunk from the phantom surface to avoid artifact-driven results in the beam-let intensity. Treatment techniques using a pair of tangential wedged fields (TWFs) and 4-field intensity-modulated radiation therapy (IMRT) were designed with a prescribed fraction dose (D{sub p}) of 180 cGy. Superficial dose profiles around the phantom circumference at depths of 0, 1, 2, 3, and 5 mm were obtained for each treatment technique using radiochromic external beam therapy (EBT) films. EBT film exhibits good characteristics for dose measurements in the buildup region. Underdoses at the median and lateral regions of the TWF plans were shown. The dose profiles at shallow depths for the TWF plans show a dose buildup about 3 mm at the median and lateral tangential incident regions with a surface dose of about 52% of D{sub p}. The dose was gradually increased toward the most obliquely tangential angle with a maximum dose of about 118% of D{sub p.} Dose profiles were more uniform in the PTV region for the 4-F IMRT plans. Most of the PTV region had doses >94% of D{sub p} at depths >1 mm. The mean surface dose was about 65% of D{sub p} for the 4-F IMRT plans. The maximum dose for the 4-F IMRT plans was <118.4% of D{sub p}. The application of added bolus has to consider the treatment technique, tumor coverage, and possible skin reactions. For PMRT, if the chest surface and wall are treated adequately, at least 3 mm bolus should be added to the chest wall when tangential beams and 6-MV photon energy are arranged. However, when the surface and superficial regions are not high-risk areas, an IMRT plan with tangential beams and 6-MV photon energy can provide uniform dose distributions within the PTV, spare the skin reaction, and deliver sufficient doses to the chest wall at depths >1 mm.

61 RADIATION PROTECTION AND DOSIMETRY↗

An Analytic Benchmark for Neutron Boltzmann Transport with Downscattering—Part I: Flux and Eigenvalue Solutions

Computing in the energy dimension is one of the greatest challenges confronting present-day deterministic neutron transport solvers. Accurately resolving the neutron flux as neutrons downscatter across resonances in the nuclear cross sections currently requires considerable computing power and suffers from approximation errors. Flux uncertainty resulting from the uncertainty of the resonance structure is the single-largest cause of reactivity uncertainty. Any additional reference solution for the critical neutron downscattering problem with resonance phenomena would be a boon to verification and validation of neutronics codes. This paper establishes a benchmark to verify the accuracy of neutron transport criticality solvers along the energy dimension. For the first time, the analytic solution of the flux amplitude is derived in the particular case of an infinite homogeneous medium with isotropic scattering in the center of mass and an arbitrary number of no-threshold, neutral particle reaction resonances (e.g., radiative capture, fission, and resonance scattering). Furthermore, original analytic expressions are established to quantify the discrepancy between the ψ k (E) and ψ α (E) flux amplitudes, respective solutions of the multiplication factor k, or the exponential time-evolution frequency α eigenproblems. The physical study of these relations led to analysis of their first-order relative difference near the criticality condition α=0. Finally, numerical solutions are provided to a benchmark problem constituted of the first resonance of 239 Pu, the 6.67-eV resonance of 238 U, and a scattering isotope with a flat cross section, allowing for the computational verification of the energy resolution of current neutron transport criticality codes. Through these novel results, this analytic benchmark can serve as a reference to verify the energy resolution and sensitivity analysis of neutron transport criticality calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Systems usability case in stepwise control room validation - 125

We present a Systems Usability Case (SUC) approach enabling a requirement-based human factors evaluation of complex technical systems. The approach is especially suitable for stepwise verification and validation (V and V) of nuclear power plant (NPP) control room (CR) systems. A SUC is based on the Safety Case approach and on the Systems Usability (SU) construct. A series of V and V test activities carried throughout the design process and constructed according to SUC enables us to monitor how evaluation evidence is aggregated over variety of V and V steps and how the design solution is maturing towards a tool of a good quality and usability. The paper demonstrates an application of the SUC approach to real data from a stepwise CR validation. The results suggest that SUC has some clear advantages. It makes it easier to conduct the V and V activities in a more systematic fashion and it makes the reasoning process more explicit and transparent. Moreover, it enables building a longitudinal view of the progress of the design process. Most importantly, constructing the SUC enables monitoring of the fulfilment of the requirements from the human factors (i.e., SU) perspective. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-F-T-288: Impact of Trajectory Log Files for Clarkson-Based Independent Dose Verification of IMRT and VMAT

Purpose: To investigate the effect of the trajectory files from linear accelerator for Clarkson-based independent dose verification in IMRT and VMAT plans. Methods: A CT-based independent dose verification software (Simple MU Analysis: SMU, Triangle Products, Japan) with a Clarksonbased algorithm was modified to calculate dose using the trajectory log files. Eclipse with the three techniques of step and shoot (SS), sliding window (SW) and Rapid Arc (RA) was used as treatment planning system (TPS). In this study, clinically approved IMRT and VMAT plans for prostate and head and neck (HN) at two institutions were retrospectively analyzed to assess the dose deviation between DICOM-RT plan (PL) and trajectory log file (TJ). An additional analysis was performed to evaluate MLC error detection capability of SMU when the trajectory log files was modified by adding systematic errors (0.2, 0.5, 1.0 mm) and random errors (5, 10, 30 mm) to actual MLC position. Results: The dose deviations for prostate and HN in the two sites were 0.0% and 0.0% in SS, 0.1±0.0%, 0.1±0.1% in SW and 0.6±0.5%, 0.7±0.9% in RA, respectively. The MLC error detection capability shows the plans for HN IMRT were the most sensitive and 0.2 mm of systematic error affected 0.7% dose deviation on average. Effect of the MLC random error did not affect dose error. Conclusion: The use of trajectory log files including actual information of MLC location, gantry angle, etc should be more effective for an independent verification. The tolerance level for the secondary check using the trajectory file may be similar to that of the verification using DICOM-RT plan file. From the view of the resolution of MLC positional error detection, the secondary check could detect the MLC position error corresponding to the treatment sites and techniques. This research is partially supported by Japan Agency for Medical Research and Development (AMED)

60 APPLIED LIFE SCIENCES↗

Optical-property coefficient estimation of bulky medium in experiments with a succinctly analytical calculation

Diffuse optical imaging enables to reconstruct distribution of optical properties, absorption and scattering coefficients, in tissue for breast cancer detection based on diffusion equation with the help of the initial guess obtained from measured data. To estimate the initial guess of the optical-property coefficients, an analytical solution of diffusion equation can be used and compared with the measured data. The analytical solution for a homogeneous infinite medium can be obtained in the frequency domain, expressing that the photon intensity and the phase lag relative to the distance between source and detector in a linear relationship. In this study, a succinct calculation using the trigonometric relation is proposed to estimate the optical-property coefficients. A tank-type and a cylinder Lipovenoes phantoms with two concentrations of 1.25% and 2.5% are employed and measured for verification. It is found that the method proposed here shows better results and results in estimation errors of 0–14.81% for μ{sub a} and 20–42% for μ{sub s}′.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Unravelling the electrochemical double layer by direct probing of the solid/liquid interface

The electrochemical double layer plays a critical role in electrochemical processes. Whilst there have been many theoretical models predicting structural and electrical organization of the electrochemical double layer, the experimental verification of these models has been challenging due to the limitations of available experimental techniques. The induced potential drop in the electrolyte has never been directly observed and verified experimentally, to the best of our knowledge. In this study, we report the direct probing of the potential drop as well as the potential of zero charge by means of ambient pressure X-ray photoelectron spectroscopy performed under polarization conditions. By analyzing the spectra of the solvent (water) and a spectator neutral molecule with numerical simulations of the electric field, we discern the shape of the electrochemical double layer profile. In addition, we determine how the electrochemical double layer changes as a function of both the electrolyte concentration and applied potential.

36 MATERIALS SCIENCE↗

Nonintrusive manufactured solutions for ablation

The study of heat transfer and ablation plays an important role in many problems of scientific and engineering interest. As with the computational simulation of any physical phenomenon, the first step toward establishing credibility in ablation simulations involves code verification. Code verification is typically performed using exact and manufactured solutions. However, manufactured solutions generally require the invasive introduction of an artificial forcing term within the source code such that the code solves a modified problem for which the solution is known. In this paper, we present a nonintrusive method for manufacturing solutions for a non-decomposing ablation code, which does not require the addition of a source term.

42 ENGINEERING↗

A convolution model for obtaining the response of an ionization chamber in static non standard fields

Purpose: This work contains an alternative methodology for obtaining correction factors for ionization chamber (IC) dosimetry of small fields and composite fields such as IMRT. The method is based on the convolution/superposition (C/S) of an IC response function (RF) with the dose distribution in a certain plane which includes chamber position. This method is an alternative to the full Monte Carlo (MC) approach that has been used previously by many authors for the same objective. Methods: The readout of an IC at a point inside a phantom irradiated by a certain beam can be obtained as the convolution of the dose spatial distribution caused by the beam and the IC two-dimensional RF. The proposed methodology has been applied successfully to predict the response of a PTW 30013 IC when measuring different nonreference fields, namely: output factors of 6 MV small fields, beam profiles of cobalt 60 narrow fields and 6 MV radiosurgery segments. The two-dimensional RF of a PTW 30013 IC was obtained by MC simulation of the absorbed dose to cavity air when the IC was scanned by a 0.6 x 0.6 mm{sup 2} cross section parallel pencil beam at low depth in a water phantom. For each of the cases studied, the results of the IC direct measurement were compared with the corresponding obtained by the C/S method. Results: For all of the cases studied, the agreement between the IC direct measurement and the IC calculated response was excellent (better than 1.5%). Conclusions: This method could be implemented in TPS in order to calculate dosimetry correction factors when an experimental IMRT treatment verification with in-phantom ionization chamber is performed. The miss-response of the IC due to the nonreference conditions could be quickly corrected by this method rather than employing MC derived correction factors. This method can be considered as an alternative to the plan-class associated correction factors proposed recently as part of an IAEA work group on nonstandard field dosimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A study of the dynamics of rotating space stations with elastically connected counterweight and attached flexible appendages. Volume 1: Theory

The formulation of a mathematical model for predicting the dynamic behavior of rotating flexible space station configurations was conducted. The overall objectives of the study were: (1) to develop the theoretical techniques for determining the behavior of a realistically modeled rotating space station, (2) to provide a versatile computer program for the numerical analysis, and (3) to present practical concepts for experimental verification of the analytical results. The mathematical model and its associated computer program are described.

Austin, F.↗

Space Shuttle OMS engine valve technology

Valve technology program to determine shutoff valve concepts suitable for the Orbital Maneuvering System (OMS) engine of the Space Shuttle. The tradeoff studies selected the electric torque motor operated dual poppet and ball valves as the most desirable valve concepts for the OMS Engine Shutoff Valve. A prototype of one of these concepts was built and subjected to a design verification program. A number of unique features were designed to include the required contamination insensitivity, operating fluid compatibility, decontamination capability, minimum maintenance requirement and long service life capability.

Wichmann, H.↗

Space Shuttle status and performance improvements

Following nearly a decade of studies and development, the Space Shuttle is beginning its flight test phase. This paper reviews the status of the program, and preparations of the space vehicle and facilities for flight. The launch preparations, including conduct of the Mission Verification Test, which comprises a Flight Readiness Firing prior to the actual launch, is discussed. This simulation was designed to test the readiness of the complete organization and all ground and flight equipment for commitment to the first manned orbital flight. The plan of the orbital flight program is outlined indicating how each succeeding flight is made more complex and severe to incrementally test the Space Shuttle. Completion of this four flight program readies the Space Shuttle for operations in late 1982. Payload performance to orbit is increased as the program progresses through the development flights and on into operations.

Day, L. E.↗

Lessons learned in ground processing scientific and applications payloads at Kennedy Space Center

The payload ground processing of experiments which flew on the Shuttle is examined, including studies of atmosphere and earth observation, life science, advance technology, materials science, plasma physics, astrophysics and solar physics, astronomy, navigation and communication, and fluid mechanics. The process of designing and development payloads, the integration of instruments, carrier interface verification, and late servicing at the launch pad are discussed. The problems of cost, red tape, contamination, safety, and propriety protection are considered.

Elfrey, Priscilla↗

Development and verification of global/local analysis techniques for laminated composites

A two-dimensional to three-dimensional global/local finite element approach was developed, verified, and applied to a laminated composite plate of finite width and length containing a central circular hole. The resulting stress fields for axial compression loads were examined for several symmetric stacking sequences and hole sizes. Verification was based on comparison of the displacements and the stress fields with those accepted trends from previous free edge investigations and a complete three-dimensional finite element solution of the plate. The laminates in the compression study included symmetric cross-ply, angle-ply and quasi-isotropic stacking sequences. The entire plate was selected as the global model and analyzed with two-dimensional finite elements. Displacements along a region identified as the global/local interface were applied in a kinematically consistent fashion to independent three-dimensional local models. Local areas of interest in the plate included a portion of the straight free edge near the hole, and the immediate area around the hole. Interlaminar stress results obtained from the global/local analyses compares well with previously reported trends, and some new conclusions about interlaminar stress fields in plates with different laminate orientations and hole sizes are presented for compressive loading. The effectiveness of the global/local procedure in reducing the computational effort required to solve these problems is clearly demonstrated through examination of the computer time required to formulate and solve the linear, static system of equations which result for the global and local analyses to those required for a complete three-dimensional formulation for a cross-ply laminate. Specific processors used during the analyses are described in general terms. The application of this global/local technique is not limited software system, and was developed and described in as general a manner as possible.

Thompson, Danniella Muheim↗

SU-E-T-506: Dosimetric Verification of Photon MLC Delivered Electron Fields for Implementing MERT On An Artiste Linac

Purpose: To verify the dose accuracy of photon MLC delivered electron fields for implementing energy-intensity modulated electron radiotherapy (MERT) on an Artiste linac. Methods: It was proposed to deliver MERT on an Artiste linac at a short SSD (60 cm) to reduce beam penumbra caused by electron scatters. An in-house developed Monte Carlo (MC)-based dose calculation/optimization planning code was used for treatment planning. Our previous study showed that the measured dose distribution of a breast plan showed good agreement with the calculations in low-medium dose regions while the differences in high dose regions were outstanding. A continuous work found that the discrepancy is mainly caused by improper modeling in MC for the single focused MLC in the Artiste which was simplified as double focused in the previous MC simulations. With this remodeled MLC in the calculations, an energy-intensity modulated electron plan using 6, 9, 12 and 15 MeV was generated for a breast treatment on a breast phantom at a 60 cm SSD and recalculated regarding a solid water phantom. For a test study, four of MLC segments (each with a different energy) generated in the plan were delivered to the phantom and a film measurement was performed at the depth of 2 cm. The measured 2D dose distribution was then compared with calculations. Results: For composite doses of the four segments, measured 2D dose distributions overall agree well with the calculations (3mm/3%) in most area. The separate measurement for a single MLC segment for each of energies also showed the consistence with the calculations. Conclusion: After remodeling MLC in the MC calculations, the measured dose distribution for a subset of MLC segments from a MERT plan showed good agreement. Further detailed verification for the full plan will be the work in the next step.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-P-40: Analysis of Pelvic Lymph Node Margin Using Prostate Fiducial Markers, for SBRT Treatments

Purpose: The use of fiducials markers in prostate treatment allows a precise localization of this volume. Typical prostate SBRT margins with fiducials markers are 5mm in all directions, except toward the rectum, where 3mm is used. For some patients nearby pelvic lymph nodes with 5mm margin need to be irradiate assuming that its localization is linked to the prostate fiducial markers instead of bony anatomy. The purpose of this work was to analyze the geometric impact of locate the lymph node regions through the patient positioning by prostate fiducial markers. Methods: 10 patients with prostate SBRT with lymph nodes irradiation were selected. Each patient had 5 implanted titanium fiducial markers. A Novalis TX (BrainLAB-Varian) with ExacTrac and aSi1000 portal image was used. Treatment plan uses 11 beams with a dose prescription (D95%) of 40Gy to the prostate and 25Gy to the lymph node in 5 fractions. Daily positioning was carried out by ExacTrac system based on the implanted fiducials as the reference treatment position; further position verification was performed using the ExacTrac and two portal images (gantry angle 0 and 90) based on bony structures. Comparison between reference position with bony based ExacTrac and portal image localization, was done for each treatment fraction Results: A total of 50 positioning analysis were done. The average discrepancy between reference treatment position and ExacTrac based on bony anatomy (pubic area) was 4.2mm [0.3; 11.2]. The discrepancy was <5mm in 61% of the cases and <9mm in 92%. Using portal images the average discrepancy was 3.7mm [0.0; 11.1]. The discrepancy was <5mm in 69% of the cases and <9mm in 96%. Conclusion: Localizing lymph node by prostate fiducial markers may produce large discrepancy as large as 11mm compared to bony based localization. Dosimetric impact of this discrepancy should be studied.

60 APPLIED LIFE SCIENCES↗