Search NASA⌕ Search

SEARCH · Search NASA

Results for “Biomedical Applications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Spaceflight Biospecimen and Data Sharing in Support of Science Discovery and Exploration

For decades, NASA and international partners have conducted biological experiments in space to understand effects of spaceflight and address potential hazards. To enable spaceflight back to the Moon, and then to Mars and beyond, it is imperative to further understand basic science and health risks associated with spaceflight, along with developing countermeasures. The sending of experiments and organisms into space is a costly endeavor. To maximize scientific return, sharing with the scientific community both space-flown biospecimens and data from completed experiments is essential. New fundamental, applied, and bioinformatic science insights can be gained from specimen and data sharing efforts. Data reuse enables spaceflight health risk modeling, analyzing adverse outcomes across spaceflight hazards, and deep space autonomous support for the flight medical officer. Space-flown biospecimens not required by mission Principal Investigators are regularly archived and made available for scientific request. The largest biorepository of these samples are found within NASA’s Institutional Scientific Collection at Ames Research Center (ISC-ARC), which stores over 32,000 specimens mostly from Shuttle and International Space Station (ISS) missions, but also some ground-based analog samples. The Ames Life Sciences Data Archive manages the ISC-ARC. Tissues are predominantly from mice and rats, though samples are also available from bacteria and quail. Only a handful of other similar collections exist worldwide. Rodent biospecimens exposed to simulated space radiation at Brookhaven National Laboratory are archived under the purview of NASA HRP Space Radiation Element. Microbial collection and analyses from 20 years of routine environmental monitoring of air, surfaces, and water systems of the ISS were performed to ensure a safe environment for astronauts. Samples from the ISC-ARC, space radiation and microbial collections are searchable and requestable through the NASA Life Sciences Data Archive (LSDA). Decades of planetary protection microbial isolates derived from spacecraft bioburden are archived in JPL’s microbial collection. Rodent biospecimens from spaceflight investigations conducted by the Japan Aerospace Exploration Agency (JAXA) are archived and available at the JAXA Biorepository at Tsukuba Space Center. The Russian Institute of Biomedical Problems also has a collection of animal, microbial, cellular, and fungi available for research from ground analog experiments. Several data repositories exist for scientists to utilize. The LSDA is the primary NASA source of life sciences research data and information. It contains decades of spaceflight and ground-analog research involving human, microbial, cellular, plant, and animal subjects. Data is collected from NASA-funded investigations through the Human Research Program and the Space Biology Program. The NASA Lifetime Surveillance of Astronaut Health collects and grants access to clinical and occupational health monitoring data from astronauts, with a list and description of data collected available for request through the LSDA. NASA GeneLab at ARC collects genomic, transcriptomic, proteomic, and metabolomic data from any species. It is a repository and platform for collaborative open-science bioinformatic approaches. JAXA is establishing an ‘omics-based repository in collaboration with the Tohoku Medical Megabank (ToMMo), called the JAXA-ToMMo Integrated Biobank for Space Life Science. Overall, the sharing of these biospecimen and data resources can assist researchers worldwide in understanding spaceflight effects on biology, along with enabling next generation data science applications for space exploration platforms. Websites: https://lsda.jsc.nasa.gov/ ; https://www.nasa.gov/ames/research/space-biosciences/isc-bsp ; https://www.nasa.gov/ames/research/space-biosciences/alsda

Ryan T. Scott↗

Enhanced imaging of microcalcifications in digital breast tomosynthesis through improved image-reconstruction algorithms

Purpose: The authors develop a practical, iterative algorithm for image-reconstruction in undersampled tomographic systems, such as digital breast tomosynthesis (DBT). Methods: The algorithm controls image regularity by minimizing the image total p variation (TpV), a function that reduces to the total variation when p=1.0 or the image roughness when p=2.0. Constraints on the image, such as image positivity and estimated projection-data tolerance, are enforced by projection onto convex sets. The fact that the tomographic system is undersampled translates to the mathematical property that many widely varied resultant volumes may correspond to a given data tolerance. Thus the application of image regularity serves two purposes: (1) Reduction in the number of resultant volumes out of those allowed by fixing the data tolerance, finding the minimum image TpV for fixed data tolerance, and (2) traditional regularization, sacrificing data fidelity for higher image regularity. The present algorithm allows for this dual role of image regularity in undersampled tomography. Results: The proposed image-reconstruction algorithm is applied to three clinical DBT data sets. The DBT cases include one with microcalcifications and two with masses. Conclusions: Results indicate that there may be a substantial advantage in using the present image-reconstruction algorithm for microcalcification imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-533: LET Dependence Correction of Radiochromic Films for Application in Low Energy Proton Irradiation

Purpose: Many cell irradiation experiments with low-energy laser-driven ions rely on radiochromic films (RCF), because of their dose-rate independent response and superior spatial resolution. RCF dosimetry in low-energy ion beams requires a correction of the LET dependent film response. The relative efficiency (RE), the ratio of photon to proton dose that yields the same film darkening, is a measure for the film’s LET dependence. A direct way of RE determination is RCF irradiation with low-energy mono-energetic protons and hence, well-defined LET. However, RE is usually determined using high energy proton depth dose measurements where RE corrections require knowledge of the average LET in each depth, which can be either track (tLET) or dose (dLET) averaged. The appropriate LET concept has to be applied to allow a proper film response correction. Methods: Radiochromic EBT2 and EBT3 films were irradiated in clinical photon and proton beams. For each depth of the 200 MeV proton depth dose curve, tLET and dLET were calculated by special user routines from the Monte Carlo code FLUKA. Additional irradiations with mono-energetic low energy protons (4–20 MeV) serve as reference for the RE determination. Results: The difference of dLET and tLET increases with depth, with the dLET being almost twice as large as the tLET for the maximum depth. The comparison with mono-energetic measurements shows a good agreement of the RE for the dLET concept, while a considerably steeper drop in RE is observed when applying the tLET. Conclusion: RCF can be used as reference dosimeter for biomedical experiments with low-energy proton beams if appropriate LET corrections are applied. When using depth dose measurements from clinical proton accelerators for these corrections, the concept of dLET has to be applied. Acknowledgement: This work was funded by the DFG Cluster of Excellence ‘Munich-Centre for Advanced Photonics’ (MAP). This work was funded by the DFG Cluster of Excellence Munich-Centre for Advanced Photonics (MAP)

61 RADIATION PROTECTION AND DOSIMETRY↗

Fluorescent 6-amino-6-deoxyglycoconjugates for glucose transporter mediated bioimaging

Two novel fluorescent bioprobes, namely, 6N-Gly-Cy3 and 6N-Gly-Cy5, were designed and synthesized for real-time glucose transport imaging as well as potentially useful tracer for galactokinase metabolism. The structure of the bioprobes was fully characterized by {sup 1}H NMR, {sup 13}C NMR, IR, and HRMS. The fluorescence properties, glucose transporter (GLUT) specificity, and the quenching and safety profiles were studied. The cellular uptake of both bioprobes was competitively diminished by D-glucose, 2-deoxy-D-glucose and GLUT specific inhibitor in a dose-dependent manner in human colon cancer cells (HT29). Comparison study results revealed that the 6N-derived bioprobes are more useful for real-time imaging of cell-based glucose uptake than the structurally similar fluorescent tracer 6-NBDG which was not applicable under physiological conditions. The up to 96 h long-lasting quenching property of 6N-Gly-Cy5 in HT29 suggested the potential applcability of the probe for cell labeling in xenograft transplantation as well as in vivo animal imaging studies. - Highlights: • Cy-3 and Cy-5 derived fluorescent 6-amino-6-deoxyglycoconjugates were prepared for glucose transporter mediated bioimaging. • The cellular uptake of the probes was inhibited by natural GLUT substrates and inhibitor. • The probes are useful for real-time imaging of cell-based glucose uptake under physiological conditions. • The probes showed up to 96 h long-lasting quenching profile in labeled cancer cells.

60 APPLIED LIFE SCIENCES↗

SU-E-T-58: Calculation of Dose Distribution of Accuboost Brachytherapy in Deformable Polyvinil Alcohol Breast Phantom Using Biomechanical Modeling and Monte Carlo Simulation

Purpose: the accuboost is the most modern method of breast brachytherapy that is a boost method in compressed tissue by a mammography unit. the dose distribution in uncompressed tissue, as compressed tissue is important that should be characterized. Methods: In this study, the mechanical behavior of breast in mammography loading, the displacement of breast tissue and the dose distribution in compressed and uncompressed tissue, are investigated. Dosimetry was performed by two dosimeter methods of Monte Carlo simulations using MCNP5 code and thermoluminescence dosimeters. For Monte Carlo simulations, the dose values in cubical lattice were calculated using tally F6. The displacement of the breast elements was simulated by Finite element model and calculated using ABAQUS software, from which the 3D dose distribution in uncompressed tissue was determined. The geometry of the model is constructed from MR images of 6 volunteers. Experimental dosimetery was performed by placing the thermoluminescence dosimeters into the polyvinyl alcohol breast equivalent phantom and on the proximal edge of compression plates to the chest. Results: The results indicate that using the cone applicators would deliver more than 95% of dose to the depth of 5 to 17mm, while round applicator will increase the skin dose. Nodal displacement, in presence of gravity and 60N forces, i.e. in mammography compression, was determined with 43% contraction in the loading direction and 37% expansion in orthogonal orientation. Finally, in comparison of the acquired from thermoluminescence dosimeters with MCNP5, they are consistent with each other in breast phantom and in chest's skin with average different percentage of 13.7±5.7 and 7.7±2.3, respectively. Conclusion: The major advantage of this kind of dosimetry is the ability of 3D dose calculation by FE Modeling. Finally, polyvinyl alcohol is a reliable material as a breast tissue equivalent dosimetric phantom that provides the ability of TLD dosimetry for validation.

60 APPLIED LIFE SCIENCES↗

A polymer/fullerene based photodetector with extremely low dark current for x-ray medical imaging applications

Organic photodetectors for use in medical x-ray digital imaging applications are fabricated from poly(3-hexylthiophene) and [6,6]-phenyl C{sub 61}-butyric acid methyl ester using a solution-based, temperature assisted deposition protocol. In comparison to bulk heterojunction structures, the proposed protocol leads to much lower dark currents while still offering useful external quantum efficiency values. Devices made by this protocol lead to dark currents of around 50 pA/cm{sup 2} at -0.8 V, well within the requirements for x-ray digital imaging. When coupled to a scintillating phosphor screen the device yields a linear response of photocurrent to x-ray exposure (from 0 to 7mGy/s) for a range of operating biases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Towards Prediction of Non-Radiative Decay Pathways in Organic Compounds I: The Case of Naphthalene Quantum Yields

Many emerging technologies depend on human’s ability to control and manipulate the excited-state properties of molecular systems. These technologies include fluorescent labeling in biomedical imaging, light harvesting in photovoltaics, and electroluminescence in light-emitting devices. All of these systems suffer from non-radiative loss pathways that dissipate electronic energy as heat, which causes the overall system efficiency to be directly linked to quantum yield (Φ) of the molecular excited state. Unfortunately, Φ is very difficult to predict from first principles because the description of a slow non-radiative decay mechanism requires an accurate description of long-timescale excited-state quantum dynamics. In the present study, we introduce an efficient semi-empirical method of calculating the fluorescence quantum yield (Φ fl ) for molecular chromophores, which converts simple electronic energies computed using time-dependent density functional theory (TDDFT) into an estimate of Φ fl . As with all machine learning strategies, the algorithm needs to be trained on fluorescent dyes for which Φ fl ’s are known, so as to provide a black-box method which can later predict Φfl’s for chemically similar chromophores that have not been studied experimentally. Here, as a first illustration of how our proposed algorithm can be trained, we examine a family of 25 naphthalene derivatives. The simplest application of the energy gap law is found to be inadequate to explain the rates of internal conversion (IC) or intersystem crossing (ISC) – the electronic properties of at least one higher-lying electronic state (S n or T n ) or one far-from-equilibrium geometry are typically needed to obtain accurate results. Indeed, the key descriptors turn out to be the transition state between the Franck–Condon minimum and a distorted local minimum near an S 0 /S 1 conical intersection (which governs IC) and the magnitude of the spin-orbit coupling (which governs ISC). The resulting Φ fl ’s are predicted with reasonable accuracy (~ 22%), making our approach a promising ingredient for high-throughput screening and rational design of the molecular excited states with desired Φ fl ’s. We thus conclude that our model, while semi-empirical in nature, does in fact extract sound physical insight into the challenge of describing non-radiative relaxations.

36 MATERIALS SCIENCE↗

Cardiovascular and Interventional Radiological Society of Europe Guidelines on Endovascular Treatment in Aortoiliac Arterial Disease

Purpose: These guidelines are intended for use in assessing the standard for technical success and safety in aorto-iliac percutaneous endovascular interventions. Methods: Any recommendation contained in the text comes from the highest level and extension of literature review available to date. Results: The success of endovascular procedures is strictly related to an accurate planning based mainly on CT- or MR-angiography. TASC II A through C lesions have an endovascular-first option Pre-procedure ASA antiplatelet therapy is advisable in all cases. The application of stents improves the immediate hemodynamic and most likely long-term clinical results. Cumulative mean complication rate is 7.51 % according to the most relevant literature. Most of the complications can be managed by means of percutaneous techniques. Conclusion: The design and quality of devices, as well as the easy and accuracy of performing these procedures, have improved over the last decades, leading to the preferential treatment of aorto-iliac steno-obstructive disease via endovascular means, often as first-line therapy, with high technical success rate and low morbidity. This is mirrored by the decreasing number of patients undergoing surgical grafts over the last years with patency, limb salvage, and survival rates equivalent to open reconstruction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison and uncertainty evaluation of different calibration protocols and ionization chambers for low-energy surface brachytherapy dosimetry

Purpose: A surface electronic brachytherapy (EBT) device is in fact an x-ray source collimated with specific applicators. Low-energy (<100 kVp) x-ray beam dosimetry faces several challenges that need to be addressed. A number of calibration protocols have been published for x-ray beam dosimetry. The media in which measurements are performed are the fundamental difference between them. The aim of this study was to evaluate the surface dose rate of a low-energy x-ray source with small field applicators using different calibration standards and different small-volume ionization chambers, comparing the values and uncertainties of each methodology. Methods: The surface dose rate of the EBT unit Esteya (Elekta Brachytherapy, The Netherlands), a 69.5 kVp x-ray source with applicators of 10, 15, 20, 25, and 30 mm diameter, was evaluated using the AAPM TG-61 (based on air kerma) and International Atomic Energy Agency (IAEA) TRS-398 (based on absorbed dose to water) dosimetry protocols for low-energy photon beams. A plane parallel T34013 ionization chamber (PTW Freiburg, Germany) calibrated in terms of both absorbed dose to water and air kerma was used to compare the two dosimetry protocols. Another PTW chamber of the same model was used to evaluate the reproducibility between these chambers. Measurements were also performed with two different Exradin A20 (Standard Imaging, Inc., Middleton, WI) chambers calibrated in terms of air kerma. Results: Differences between surface dose rates measured in air and in water using the T34013 chamber range from 1.6% to 3.3%. No field size dependence has been observed. Differences are below 3.7% when measurements with the A20 and the T34013 chambers calibrated in air are compared. Estimated uncertainty (with coverage factor k = 1) for the T34013 chamber calibrated in water is 2.2%–2.4%, whereas it increases to 2.5% and 2.7% for the A20 and T34013 chambers calibrated in air, respectively. The output factors, measured with the PTW chambers, differ by less than 1.1% for any applicator size when compared to the output factors that were measured with the A20 chamber. Conclusions: Measurements using both dosimetric protocols are consistent, once the overall uncertainties are considered. There is also consistency between measurements performed with both chambers calibrated in air. Both the T34013 and A20 chambers have negligible stem effect. Any x-ray surface brachytherapy system, including Esteya, can be characterized using either one of these calibration protocols and ionization chambers. Having less correction factors, lower uncertainty, and based on measurements, performed in closer to clinical conditions, the TRS-398 protocol seems to be the preferred option.

60 APPLIED LIFE SCIENCES↗

Malaria Modeling using Remote Sensing and GIS Technologies

Malaria has been with the human race since the ancient time. In spite of the advances of biomedical research and the completion of genomic mapping of Plasmodium falciparum, the exact mechanisms of how the various strains of parasites evade the human immune system and how they have adapted and become resistant to multiple drugs remain elusive. Perhaps because of these reasons, effective vaccines against malaria are still not available. Worldwide, approximately one to three millions deaths are attributed to malaria annually. With the increased availability of remotely sensed data, researchers in medical entomology, epidemiology and ecology have started to associate environmental and ecological variables with malaria transmission. In several studies, it has been shown that transmission correlates well with certain environmental and ecological parameters, and that remote sensing can be used to measure these determinants. In a NASA project, we have taken a holistic approach to examine how remote sensing and GIs can contribute to vector and malaria controls. To gain a better understanding of the interactions among the possible promoting factors, we have been developing a habitat model, a transmission model, and a risk prediction model, all using remote sensing data as input. Our objectives are: 1) To identify the potential breeding sites of major vector species and the locations for larvicide and insecticide applications in order to reduce costs, lessen the chance of developing pesticide resistance, and minimize the damage to the environment; 2) To develop a malaria transmission model characterizing the interactions among hosts, vectors, parasites, landcover and environment in order to identify the key factors that sustain or intensify malaria transmission, and 3) To develop a risk model to predict the occurrence of malaria and its transmission intensity using epidemiological data and satellite-derived or ground-measured environmental and meteorological data.

Kiang, Richard↗

Benefits of Synchrotron Microangiography for Dynamic Studies of Smooth Muscle and Endothelial Roles in the Pathophysiology of Vascular Disease

Changes in endothelial and smooth muscle function compromise organ perfusion in the chronic disease states of diabetes, atherosclerosis and hypertension. Moreover, vascular dysfunction increases the likelihood of lethal acute events such as myocardial infarction and stroke, which are now leading causes of adult mortality. Many circulating and local tissue factors in these disease states contribute to impaired vasomotor regulation of the arterial vessels, leading to spasm, chronic constriction and eventually vessel remodelling. X-ray contrast absorption imaging allows assessment of vessel lumen diameter and the factors contributing to steady-state vessel calibre, however, conventional clinical devices (>200 {mu}m resolution) are not adequate to detect microvessels or accurately assess function in real time. Using synchrotron imaging we are now able to detect small vessel calibres ({approx}30 {mu}m) and quantify regional differences in calibre even under conditions of high heart rate (>500 bpm). Herein we describe recent experiments that were conducted at the Japanese Synchrotron, SPring-8 using anaesthetised Sprague-Dawley rats and C57Bl/6 mice and a synchrotron radiation contrast angiography (single narrow energy bandwidth) approach based on selective arterial injection of iodine contrast agents. Application of this approach to imaging of the heart and other vasculatures are described. Our studies show that within-animal comparisons of 3-4 branching orders of arterial vessels are possible using small bolus contrast injections and appropriate contrast washout times (15-30 min) in many organ systems. Determination of relative calibre changes before and after any treatment allows us to evaluate the contributions of different endogenous factors and ligand-receptor pathways in the maintenance of vasomotor tone. Finally, we will present our findings relating to novel therapies to prevent endothelial dysfunction in heart failure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-P-04: Implementation of Dose Monitoring Software: Successes and Pitfalls

Purpose: to successfully install a dose monitoring software (DMS) application to assist in CT protocol and dose management. Methods: Upon selecting the DMS, we began our implementation of the application. A working group composed of Medical Physics, Radiology Administration, Information Technology, and CT technologists was formed. On-site training in the application was supplied by the vendor. The decision was made to apply the process for all the CT protocols on all platforms at all facilities. Protocols were painstakingly mapped to the correct masters, and the system went ‘live’. Results: We are routinely using DMS as a tool in our Clinical Performance CT QA program. It is useful in determining the effectiveness of revisions to existing protocols, and establishing performance baselines for new units. However, the implementation was not without difficulty. We identified several pitfalls and obstacles which frustrated progress. Including: Training deficiencies, Nomenclature problems, Communication, DICOM variability. Conclusion: Dose monitoring software can be a potent tool for QA. However, implementation of the program can be problematic and requires planning, organization and commitment.

60 APPLIED LIFE SCIENCES↗

Carotid Artery Stenting Using a Novel Self-Expanding Braided Nickel-Titanium Stent: Feasibility and Safety Porcine Trial

We studied the deliverability and safety of a braided, self-expanding, closed-cell nickel-titanium (NiTi) stent (E-volution, Jotec GmbH, Hechingen, Germany) especially designed for the endovascular treatment of carotid artery bifurcation stenosis with special regard to in-stent stenosis and thrombosis compared with a laser-cut reference nitinol stent in a porcine model of percutaneous vascular interventions. We aimed to assess histopathologic response in minipig carotid and subclavian arteries. Eight minipigs received a total of 42 stents: 14 reference stents and 28 E-volution stents. Eleven of the E-volution stents were additionally coated with heparin. Control angiography was obtained immediately before and after vascular intervention as well as 4 weeks after the procedure. Primary endpoints were 28 days of angiographic analyses as well as histomorphometric analysis, including injury score, inflammation score, luminal diameter, vessel diameter, maximal neointimal thickness, and area of in-stent stenosis. Secondary end points were procedural success, 28-day mortality, and stent thrombosis. All stents could be delivered successfully without procedural complications, morbidity, or mortality during our observation time. As confirmed by histology, no in-stent thrombosis was observed. Compared with common carotid arteries, subclavian arteries are significantly more vulnerable to developing in-stent stenosis caused by neointima proliferation (p < 0.05). Compared with the use of 1 single stent/artery, serial application of two stents leads to a more excessive but not significantly different neointimal proliferation (p > 0.05). The E-volution stent, especially when heparin coated, is in line with the comparison to the laser-cut reference stent displaying similar results of angiographic, histologic, and histomorphometric analyses (p > 0.05). Compared with the reference laser-cut stent, the self-expanding nitinol stent (E-volution) with its advanced braiding technology is feasible and safe. In our opinion, the high radial resistive force and the advanced braided design with tight stent-strut interstices may be beneficial in terms of plaque stabilization. Further studies are necessary and warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enabling a Voice Management System for Space Applications, Design and Software Development

Sustainable missions, beyond low Earth orbit, will require autonomous capabilities in order to achieve NASA’s Artemis program objectives. Correspondingly, the crew must have a means to efficiently interact with these autonomous systems; this can be facilitated via voice and speech communications. Voice-based controls enable the user to access autonomous systems hands-free/eyes-free, allowing the user to better focus on critical tasks. The goal of this project was to explore the knowledge and technology needed to successfully design effective voice interfaces for autonomous systems. The main objective was to understand how a crew member, through voice interaction, could most efficiently and intuitively communicate with a notional autonomous vehicle system manager. This project leveraged prior research conducted by the University of Michigan’s Bioastronautics and Life Support System (BLiSS) team as part of a NASA Moon to Mars eXploration Systems and Habitation (M2M X-Hab) 2020 Academic Innovation Challenge. The X-Hab 2020 work from the BliSS Team resulted in an intuitive graphical user interface/user experience that was built on an Internet of Things (IOT) platform. The Voice User Interface (VUI) design for the M2M X-Hab 2021 project leveraged this technology and incorporated a voice-based assistant and NASA’s Platform for Autonomous Systems (NPAS) software. This required technologies to convert voice to text, conduct semantic interpretations, and convert responses from the autonomous system to text and to speech; additionally, the background noise environment of spacecraft was assessed, and a relatable personality for the autonomous system to facilitate human-like conversations was created. This work’s success was largely due to the diverse team that included expertise in Space Systems Engineering, Human Computer Interaction, Aerospace Engineering, Computer Science, Biomedical Engineering, and Applied Physics. The differing perspectives fostered elaborate discussions, resulting in the conception of three main interactions: (1) User-System, (2) NPAS-System, and (3) Environment-System. The system developed, i.e. the VUI, had to be unique, efficient, and intuitive; thus, the team crafted a personality for the system to enable human-like conversation. User surveys sent to students and young professionals were used to help determine these personality traits by capturing perspectives and expectations of the “Artemis Generation Astronauts”. To further simulate human-like conversations, the system had to be able to quickly interpret user speech and be able to integrate with NASA’s NPAS system for quick and reliable information transfer. Results of this research include (1) a working prototype user interface, that is compatible with NASA’s NPAS system; (2) software that demonstrates the ability to interpret user requests and respond appropriately; (3) the capability to implement fully expanded conversations between user and system using intuitive communication in four request categories; and (4) software and hardware recommendations that optimize the system’s ability to operate, i.e. be heard, in a noisy environment. The technologies chosen for this project’s demonstrations included the following: Raspberry Pi, RASA, Mozilla Deep Speech, Coqui, RTX Voice and Adobe XD. This work has laid the foundation for the development of VUI’s used for autonomy, and is intended to provide guidance for future VUI development.

Tara Vega↗

Psychophysiology of Spaceflight and Aviation

In space, the absence of gravity alone causes unique physiological stress. Significant biomedical changes, across multiple organ systems, such as body fluid redistribution, diminished musculoskeletal strength, changes in cardiac function and sensorimotor control have been reported. The time course of development of these disorders and severity of symptoms experienced by individuals varies widely. Space motion sickness (SMS) is an example of maladaptation to microgravity, which occurs early in the mission and can have profound effects on physical health and crew performance. Disturbances in sleep quality, perception, emotional equilibrium and mood have also been reported, with impact to health and performance varying widely across individuals. And lastly, post-flight orthostatic intolerance, low blood pressure experienced after returning to Earth, is also of serious concern. Both the Russian and American space programs have a varied list of human errors and mistakes, which adversely impacted mission goals. Continued probability of human exposure to microgravity for extended time periods provides a rationale for the study of the effects of stress. The primary focus of this research group is directed toward examining individual differences in: (a) prediction of susceptibility to these disorders, (b) assessment of symptom severity, (c) evaluation of the effectiveness of countermeasures, and (d) developing and testing a physiological training method, Autogenic-Feedback Training Exercise (AFTE) as a countermeasure with multiple applications. The present paper reports on the results of a series of human flight experiments with AFTE aboard the Space Shuttle and Mir Space Station, and during emergency flight scenarios on Earth.

Cowings, Patricia↗

MO-DE-210-03: Ultrasound imaging is an attractive method for image guided radiation treatment (IGRT), by itself or to complement other imaging modalities

Ultrasound imaging is an attractive method for image guided radiation treatment (IGRT), by itself or to complement other imaging modalities. It is inexpensive, portable and provides good soft tissue contrast. For challenging soft tissue targets such as pancreatic cancer, ultrasound imaging can be used in combination with pre-treatment MRI and/or CT to transfer important anatomical features for target localization at time of treatment. The non-invasive and non-ionizing nature of ultrasound imaging is particularly powerful for intra-fraction localization and monitoring. Recognizing these advantages, efforts are being made to incorporate novel robotic approaches to position and manipulate the ultrasound probe during irradiation. These recent enabling developments hold potential to bring ultrasound imaging to a new level of IGRT applications. However, many challenges, not limited to image registration, robotic deployment, probe interference and image acquisition rate, need to be addressed to realize the full potential of IGRT with ultrasound imaging. Learning Objectives: Understand the benefits and limitations in using ultrasound to augment MRI and/or CT for motion monitoring during radiation therapy delivery. Understanding passive and active robotic approaches to implement ultrasound imaging for intra-fraction monitoring. Understand issues of probe interference with radiotherapy treatment. Understand the critical clinical workflow for effective and reproducible IGRT using ultrasound guidance. The work of X.L. is supported in part by Elekta; J.W. and K.D. is supported in part by a NIH grant R01 CA161613 and by Elekta; D.H. is support in part by a NIH grant R41 CA174089.

60 APPLIED LIFE SCIENCES↗

MO-B-BRB-00: Three Dimensional Dosimetry

Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an irradiated volume can help understand interplay effects during TomoTherapy or VMAT. Titania Juang: Special techniques in the clinic and research Understand the potential for 3D dosimetry in validating dose accumulation in deformable systems, and Observe the benefits of high resolution measurements for precision therapy in SRS and in MicroSBRT for small animal irradiators Geoffrey S. Ibbott: 3D Dosimetry in end-to-end dosimetry QA Understand the potential for 3D dosimetry for end-to-end radiation therapy process validation in the in-house and external credentialing setting. Canadian Institutes of Health Research; L. Schreiner, Modus QA, London, ON, Canada; T. Juang, NIH R01CA100835.

60 APPLIED LIFE SCIENCES↗

Gravity Sensors and the Role of 3-D Visualization and Simulation in Biomedical Research

Ross 3.0 software was developed in the Biocomputation Center for semi-automated reconstruction of objects from serial thin sections. Data are captured directly from a transmission electron microscope via a video camera to a graphics workstation where the sections are mosaicked and contours are traced, registered and displayed by semi-automated methods. For the first time, macular type II cells are described completely for their innervation patterns. The purposes are to learn more about the fundamental circuitry of the macula and to demonstrate whether the terminals are altered morphologically by space flight. Current examples, from the medial part of the macula, are from maculas collected in-flight on the Space Life Sciences-2 mission, 4.5 hrs post-flight, and from a ground control. Results show that the typical type 11 cell receives processes from up to six nearby calyces or afferents. Nearly all the processes are elongated; some have bouton-like swellings and numerous vesicles. Multiple (2 to 4) processes from a single calyx to a type II cell are common, and approx. 1/3 of the processes innervate 2 type II cells of a neighboring cluster of 3 cells. About 2% of type II cells resemble type I cells morphologically and are surrounded by demicalyces. Differences in size or shape of the terminals under flight conditions could not be determined because the sample size is still too small; but it is clear that reconstruction methods provide insights into macular circuitry not obtainable by other techniques. The results demonstrate a morphological basis for interactions between adjacent receptive fields, through feedback-feedforward connections, during preprocessing of linear acceleratory information by the maculas. While the methods are currently being tested using vestibular maculas as the model system, it is clear that the technology is applicable to any tissue that can be physically or optically sectioned. ROSS software has already been implemented for reconstructing objects from tissues studied by confocal and by transmitted light microscopy, and research into magnetic resonance imaging-computational tomography combined visualization are underway.

Ross, Muriel D.↗