Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Model-free Load Control for High Penetration of Solar Photovoltaic Generation

This paper presents a new model-free control (MFC) mechanism that enables the local distribution level circuit consumption of the photovoltaic (PV) generation by local building loads, in particular, distributed heating, ventilation and air conditioning (HVAC) units. The local consumption of PV generation will help minimize the impact of PV generation on the distribution grid, reduce the required battery storage capacity for PV penetration, and increase solar PV generation penetration levels. The proposed MFC approach with its corresponding intelligent controllers does not require any precise modeling for buildings, where their reliable modeling is a demanding task. Even when assuming the availability of a good model, the various building architectures would compromise the performance objectives of any model-based control strategy. The objective is to consume most of the PV generation locally while maintaining occupants comfort and physical constraints of HVAC units. That is, by enabling proper scheduling of responsive loads temporally and spatially to minimize the difference between demand and PV production, it would be possible to reduce voltage variations and two-way power flow. Computer simulations show promising results where a significant proportion of the PV generation can be consumed by building HVAC units with the help of intelligent control.

Bara, Ouassim↗

Foil deposition onto an additive manufactured substrate

An additive manufacturing system and method for forming a part of dissimilar materials. The additive manufacturing system may include a build platform, a recoater for dispensing build powder onto the build platform, an energy source, a foil feed assembly, and a controller for controlling actuation of these components. The method of forming the part may include the steps of depositing a layer of build powder onto the build platform surface, melting selected portions of the layer of build powder, applying a sheet of foil over the layer of build powder, melting selected portions of the sheet of foil onto the layer of build powder, removing the sheet of foil from the layer of build powder, and then lowering the build platform surface to prepare for deposition of a next layer of the build powder. These steps are then repeated one or more times, thereby forming the part.

36 MATERIALS SCIENCE↗

Foil deposition onto an additive manufactured substrate

An additive manufacturing system and method for forming a part of dissimilar materials. The additive manufacturing system may include a build platform, a recoater for dispensing build powder onto the build platform, an energy source, a foil feed assembly, and a controller for controlling actuation of these components. The method of forming the part may include the steps of depositing a layer of build powder onto the build platform surface, melting selected portions of the layer of build powder, applying a sheet of foil over the layer of build powder, melting selected portions of the sheet of foil onto the layer of build powder, removing the sheet of foil from the layer of build powder, and then lowering the build platform surface to prepare for deposition of a next layer of the build powder. These steps are then repeated one or more times, thereby forming the part.

Green, Nicholas↗

Foil deposition onto an additive manufactured substrate

An additive manufacturing system and method for forming a part of dissimilar materials. The additive manufacturing system may include a build platform, a recoater for dispensing build powder onto the build platform, an energy source, a foil feed assembly, and a controller for controlling actuation of these components. The method of forming the part may include the steps of depositing a layer of build powder onto the build platform surface, melting selected portions of the layer of build powder, applying a sheet of foil over the layer of build powder, melting selected portions of the sheet of foil onto the layer of build powder, removing the sheet of foil from the layer of build powder, and then lowering the build platform surface to prepare for deposition of a next layer of the build powder. These steps are then repeated one or more times, thereby forming the part.

Green, Nicholas↗

Analysis of predicted mean vote-based model predictive control for residential HVAC systems

Model Predictive Control (MPC) is an advanced process control method that has attracted much attention in building heating, ventilation, and air conditioning (HVAC) systems. Here, this paper analyzes the optimal precooling performance in residential buildings using MPC with two different comfort indices, namely, temperature and predicted mean vote (PMV). It first formulates, for each comfort index, an optimization problem that accounts for different factors, such as weather, home thermal condition, prediction horizon, time-of use (TOU) utility rate, and rated cooling capacity. The problem is then solved, resulting in an MPC strategy that determines the HVAC on/off control signal and minimizes energy cost over a receding time horizon while maintaining thermal comfort. The energy performance difference between temperature-based and PMV-based MPC strategies is subsequently investigated, especially in light of the interior wall surface temperature and under different combinations of the factors. Extensive simulation results demonstrated that the proposed MPC strategies are adaptive and their performances depend primarily on weather, home thermal condition, and prediction horizon, while the impact of TOU utility rate and rated cooling capacity is relatively small. Because the PMV-based MPC strategy can take advantage of the lower interior wall surface temperature due to precooling, it resulted in 8–45% cost savings for the scenarios investigated and an average increase of 0.042–0.113 in the absolute value of the PMV index compared to the temperature-based MPC strategy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transmission of Images on High-Temperature Nuclear-Grade Metallic Pipe with Ultrasonic Elastic Waves

Transmission of information using elastic ultrasonic waves on existing metallic pipes provides an alternative communication option for a nuclear facility. The advantages of this approach consist of transmitting information through barriers, such as the containment building wall, with minimal modification of the existing hardware. Because bit rates on the order of kilobits per second are achievable, relatively large volumes of data, such as images, can be transmitted. A viable candidate for an ultrasonic communication channel is a stainless steel pipe of the chemical volume control system (CVCS) that penetrates through the reactor containment building wall through a sealed tunnel. To study ultrasonic communication under simulated nuclear facility conditions of high temperature, a test article was developed by installing heating tapes, temperature controllers, and thermal insulation on a laboratory CVCS-like stainless steel pipe. High temperature and radiation-resilient lithium niobate ultrasonic transducers were utilized for information transmission on the heated pipe. The amplitude shift keying (ASK) digital communication protocol was developed and implemented in a GNU Radio software-defined radio environment. A root-raised-cosine filter was introduced to suppress ultrasonic transducer ringing and thus reduce inter-symbol interference. This resulted in the enhancement of the data transmission bit rate compared to information encoding with square pulses. Demonstrations of communication at high temperature included transmission of a 90-KB image at the bit rate of 10 Kbps with a bit error rate of 10 -3 across a 6-ft-long straight pipe heated up to 230 degrees C. Additional preliminary studies were conducted to evaluate ultrasonic communication system resilience to environmental degradation and damage.

42 ENGINEERING↗

Use of a Heat Flow Meter to Determine Active PCM Content in an Insulation

Residential and commercial roofs and walls are currently designed and tested using steady-state criteria. The resulting R-values, based on the apparent thermal conductivity, are used by building standards as an important measure of energy performance. Building envelope components, however, are subject to dynamic environmental conditions. This mismatch between the steady-state principles used in design and code requirements and their dynamic operation results in relatively low thermal efficiencies. Although several research centers have developed experimental methods for transient analysis of building envelopes, there are no standardized testing procedures available for screening materials and systems for which performance depends on dynamic response. For example, a full-scale dynamic evaluation of phase change materials (PCMs) is needed to assess their energy saving benefits. A nationally accepted small-scale (one to two foot size specimens) testing procedure is not available for the analysis of dynamic thermal characteristics of conventional thermal mass systems or PCM-enhanced materials. At the same time, data on these characteristics are necessary for whole-building simulations, energy analysis, and energy code work. The transient characteristics of PCM-enhanced products depend on the PCM content and quality. The only readily available method of thermal evaluation uses the differential scanning calorimeter. Unfortunately, this method requires small, relatively uniform test specimens. This requirement is unrealistic in the case of PCM-enhanced building envelope products such as PCM-cellulose, PCM-glass fiber, or PCM-gypsum blends. Small specimens are not representative of PCM-based blends, since these materials are not homogeneous. Jan Kosny and David Yarbrough, Oak Ridge National Laboratory, P.O. Box 2008, MS 6070, Oak Ridge, TN 37831-6070. Elizabeth Kossecka, Polish Academy of Sciences, Institute of Fundamental Technological Research, Pawinskiego 5 B, 02-106, Warsaw, Poland. A procedure for making dynamic heat-flow measurements using existing instrumentation has been developed to analyze the benefits of thermal storage. This small-scale testing method is useful for thermal analysis and as a potential quality control method for producers of PCM-enhanced building materials. The research may provide the basis for consensus standard development. This paper uses as an example a dynamic testing process for PCM-enhanced cellulose insulation.

25 ENERGY STORAGE↗

Quaternion-Based Control Architecture for Determining Controllability/Maneuverability Limits

Dynamic inversion has often been used in the simulation environment to rapidly prototype controls for the full flight envelope, because of its capacity for assessing a vehicle s maneuver performance and proper sizing of control surfaces. Generally, the architectures involve either a direct inversion of the entire set of equations of motion or a sequential set of inversions exploiting time scale separation in the vehicle dynamics where faster parameters are considered as controls for slower varying parameters. The proposed architecture builds on the latter using a quaternion formulation that provides singularity free tracking. Of interest, the proposed architecture simplifies the sequential approach by exploiting a simpler kinematic inversion in place of a more difficult inversion typically used. This kinematic relationship accurately describes the angular rate required to drive some reference frame of interest to a desired attitude at some desired quaternion error rate. A simple PID control is used to define the desired quaternion error rate. The paper develops the theoretical framework for the approach, and shows results in tracking a desired trajectory.

Bacon, Barton J↗

Rational Design of Hierarchically Open-Porous Spherical Hybrid Architectures for Lithium Ion Batteries

Controlling the internal microstructure and overall morphology of building blocks used to form hybrid materials is crucial for the realization of deterministically designed architectures with desirable properties. Here, we demonstrate an integrative spray-frozen (SF) assembly for forming hierarchically structured open-porous microspheres (hpMSs) composed of Fe 3 O 4 and reduced graphene oxide (rGO). The SF process drives the formation of a radially-aligned microstructure within the sprayed colloidal droplets and also controls the overall microsphere morphology. The Fe 3 O 4 /rGO hpMSs contain interconnected open-pores and spherical morphology, which, when used as a lithium-ion battery anode, enables then to provide gravimetric and volumetric capacities of 1069.7 mAh g -1 and 686.7 mAh cm -3 , much greater than those of samples with similar composition and different morphologies. The hpMSs have good rate and cycling performances, retaining 78.5% from 100 to 1000 mA g -1 and 74.6% over 300 cycles. Using in-situ synchrotron x-ray absorption spectroscopy, the reaction pathway and phase evolution of the hpMSs are monitored observing the very small domain size and highly disordered nature of Fe x O y . Here, the reduced capacity fading relative to other conversion systems is due to the good electrical contact between the pulverized Fe x O y particles and rGO, the overall structural integrity of the hpMSs, and interconnected openporosity.

25 ENERGY STORAGE↗

Controls and guidance: Space

The Space Controls and Guidance Research and Technology Program is directed toward enabling the next generation of space transportation systems, large future spacecraft, and space systems such as the Space Station to have large communication antennas and high precision segmented reflector astrophysical telescopes. The new generation of transportation vehicles has demanding requirements to provide for an order of magnitude reduction in cost as well as an increase in capability. The future orbital facilities have demanding control requirements for pointing and stabilization, momentum management, build-up and growth accomodation, and disturbance management. To address these advanced requirements, the research and development program is designed to provide the generic technology base to support the implementation of advanced guidance, navigation, and control. The area of computational controls will be stressed in order to develop cost effective, high speed, high fidelity control system simulation and analysis and synthesis tools. The trust of this work will be to develop methods and software to enable analysis and real-time hardware-in-the-loop simulation of complex spacecraft for control design certification. To address future orbital facilities requirements, an advanced technology program is underway in system identification, distributed control, integrated controls/structures design methods, and advanced sensors and actuators. Because the behavior of large, light weight per unit area deployable/assembled spacecraft is greatly influenced by the ground environment, the testing and verification activity is both ground- and space-based.

Dibattista, John D.↗

Validation on Aggregate Flexibility from Residential Air Conditioning Systems for Building-to-Grid Integration

To facilitate the integration of buildings to the power grid, battery-equivalent models have been proposed to characterize and quantify aggregate flexibility from building loads. An analytical method has been proposed to construct such a flexibility model for thermostatically controlled loads. Since this analytical method is derived from a simplified representation of building thermal dynamics, it is necessary to evaluate the resulting flexibility model in a more realistic context. This paper focuses on the validation of this analytical method for estimating aggregate flexibility from residential air conditioning (ACs) systems. A high-fidelity model is first developed to mimic thermal behaviors of a residential AC system through a co-simulation between Modelica and EnergyPlus. A population of virtual residential AC systems is then generated by randomizing parameters of the high-fidelity model. Finally, an aggregate flexibility model is constructed for the residential AC population using the analytical method and validated using results from simulation of the high-fidelity model. It is found that the flexibility estimated using the analytical method is with reasonable accuracy, but can be improved by explicitly incorporating heat gains into the method.

Huang, Sen↗

Development of a standard capture efficiency test method for residential kitchen ventilation

Cooking activities are a major source of indoor air pollutants. To control pollutants generated from cooking activities, a range hood is commonly used in residential kitchens. Several building codes require that a range hood be installed in new homes to control pollutants from cooking, and the required airflow rates for range hoods are specified by indoor air quality standards. However, airflow alone does not show how much of the cooking pollutants are exhausted by the range hood. A better metric to evaluate range hood indoor air quality performance is capture efficiency -- the fraction of contaminants emitted during cooking that are exhausted directly to the outside via the range hood. The current article summarizes the development of a range hood capture efficiency test method for use in laboratory testing and equipment rating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a Standard Test Method for Reducing the Uncertainties in Measuring the Capture Efficiency of Range Hoods

Cooking activities are a major source of indoor air pollutants. To control pollutants generated from cooking activities, a range hood is commonly used in residential kitchens. Several building codes require that a range hood be installed in new homes to control pollutants from cooking, and the required airflow rates for range hoods are specified by indoor air quality (IAQ) standards. However, air flow alone does not tell us how much of the cooking pollutants are exhausted by the range hood. A better metric to evaluate range hood IAQ performance is capture efficiency (CE)—the fraction of contaminants emitted during cooking that are exhausted directly to the outside via the range hood. This paper summarizes the development of a range hood CE test method for use in laboratory testing and equipment rating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demand illumination control apparatus

Solar illuminating compensating apparatus is disclosed whereby the interior of a building is illuminated to a substantially constant, predetermined level of light intensity by a combination of natural illumination from the sun and artificial illumination from electricity wherein the intensity of said artificial illumination is controlled by fully electronic means which increases the level of artificial illumination when the natural illumination is inadequate and vice versa.

Warren, Carl↗

Controlling octahedral rotations in a perovskite via strain doping

The perovskite unit cell is the fundamental building block of many functional materials. The manipulation of this crystal structure is known to be of central importance to controlling many technologically promising phenomena related to superconductivity, multiferroicity, mangetoresistivity, and photovoltaics. The broad range of properties that this structure can exhibit is in part due to the centrally coordinated octahedra bond flexibility, which allows for a multitude of distortions from the ideal highly symmetric structure. However, continuous and fine manipulation of these distortions has never been possible. Here, we show that controlled insertion of He atoms into an epitaxial perovskite film can be used to finely tune the lattice symmetry by modifying the local distortions, i.e., octahedral bonding angle and length. Orthorhombic SrRuO 3 films coherently grown on SrTiO 3 substrates are used as a model system. Implanted He atoms are confirmed to induce out-of-plane strain, which provides the ability to controllably shift the bulk-like orthorhombically distorted phase to a tetragonal structure by shifting the oxygen octahedra rotation pattern. Lastly, these results demonstrate that He implantation offers an entirely new pathway to strain engineering of perovskite-based complex oxide thin films, useful for creating new functionalities or properties in perovskite materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Koopman-based residual modeling approach for the control of a soft robot arm

Soft robots are challenging to model and control due to their poorly defined kinematics and nonlinear dynamics. Recently, Koopman operator theory has been shown capable of constructing control-oriented soft robot models from data. However, building these models requires extensive data collection and they do not necessarily generalize well outside of the training observations. This paper presents a more data-efficient and generalizable approach to soft robot modeling that first identifies a physics-based Koopman model then supplements it with a data-driven residual Koopman model. The resulting combined model is linear and thus compatible with real-time model-based control techniques such as Model Predictive Control (MPC). The efficacy of the approach is demonstrated on several simulated systems and on a real soft robot arm, where it is shown to generate models that are more accurate than purely physics-based models and require less data to construct than purely data-driven models. Using a model-based controller, the soft arm is able to successfully track end effector trajectories, perform a pick-and-place task, and write on a dry-erase board, showcasing the applicability of this framework to increase the capabilities of soft robotic systems.

Daniel Bruder↗

Control and Management of Multiple Converters in a Residential Smart Grid

Power electronic systems are becoming a staple building block for electric grid networks. However, these systems have been largely designed to grid integrate in ad hoc configurations with little or no coordination of control. This work proposes a central controller and power electronic system hardware and software design for a residential system (photovoltaic, energy storage and residential building). This system supports auto-integration, plug and play capabilities, and optimal energy management to meet different use cases. Modelling and multi-day testing of the system have been conducted in a controller hardware-in-the-loop (C-HIL) testbed. Multiple use cases and pricing options have been considered as part of the simulation and testing. Results are presented of these systems as a proof of principle.

Starke, Michael↗