Search NASA⌕ Search

SEARCH · Search NASA

Results for “CALIBRATION STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Ensemble Kalman Filter for Dynamic State Estimation of Power Grids Stochastically Driven by Time-correlated Mechanical Input Power

State and parameter estimation of power transmission networks is important for monitoring power grid operating conditions and analyzing transient stability. Wind power generation depends on fluctuating input power levels, which are correlated in time and contribute to uncertainty in turbine dynamical models. The ensemble Kalman filter (EnKF), a standard state estimation technique, uses a deterministic forecast and does not explicitly model time-correlated noise in parameters such as mechanical input power. However, this uncertainty affects the probability of fault-induced transient instability and increased prediction bias. Here a novel approach is to model input power noise with time-correlated stochastic fluctuations, and integrate them with the network dynamics during the forecast. While the EnKF has been used to calibrate constant parameters in turbine dynamical models, the calibration of a statistical model for a time-correlated parameter has not been investigated. In this study, twin experiments on a standard transmission network test case are used to validate our time-correlated noise model framework for state estimation of unsteady operating conditions and transient stability analysis, and a methodology is proposed for the inference of the mechanical input power time-correlation length parameter using time-series data from PMUs monitoring power dynamics at generator buses.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DAmodel: hierarchical Bayesian modelling of DA white dwarfs for spectrophotometric calibration

We use hierarchical Bayesian modelling to calibrate a network of 32 all-sky faint DA white dwarf (DA WD) spectrophotometric standards (⁠16.5 < V , 19.5⁠) alongside three CALSPEC standards, from 912 Å to 32 μm. The framework is the first of its kind to jointly infer photometric zero points and WD parameters (surface gravity log g⁠, effective temperature T eff ⁠, extinction A V ⁠, dust relation parameter R V ) by simultaneously modelling both photometric and spectroscopic data. We model panchromatic Hubble Space Telescope Wide Field Camera 3 (HST/WFC3) UVIS and IR photometry, HST/STIS UV spectroscopy, and ground-based optical spectroscopy to sub-per cent precision. Photometric residuals for the sample are the lowest yet yielding < 0.004 mag RMS on average from the UV to the NIR, achieved by jointly inferring time-dependent changes in system sensitivity and WFC3/IR count-rate nonlinearity. Our GPU-accelerated implementation enables efficient sampling via Hamiltonian Monte Carlo, critical for exploring the high-dimensional posterior space. The hierarchical nature of the model enables population analysis of intrinsic WD and dust parameters. Inferred spectral energy distributions from this model will be essential for calibrating the James Webb Space Telescope as well as next-generation surveys, including Vera Rubin Observatory’s Legacy Survey of Space and Time and the Nancy Grace Roman Space Telescope.

methods: statistical↗

Uncertainty of Radiant Power Calibration based on Synchrotron Radiation caused by Spectral Distribution and Polarization State

We have been attempting to establish an absolute scale of spectral radiance in ultraviolet and vacuum ultraviolet regions by using synchrotron radiation as a primary standard light source and also attempting to transfer the absolute scale to an under-test light source by comparing the under-test source with synchrotron radiation. The calibration apparatus does not function as ideal comparator because some properties of incident radiation, which are spectral distribution and polarization state, are different between synchrotron radiation and the under-test light source, and the signal of the apparatus accordingly depends on not only spectral radiant power but also depends on the properties of the incident radiation. We evaluated how the detector signal ratio was affected by the difference both experimentally and theoretically, and also evaluated the uncertainty of the scale transfer caused by the difference.

43 PARTICLE ACCELERATORS↗

A simple method for the measurement of reflective foil emissivity

Reflective metal foil is widely used to reduce radiative heat transfer within the roof space of buildings. Such foils are typically mass-produced by vapor-deposition of a thin metallic coating onto a variety of substrates, ranging from plastic-coated reinforced paper to 'bubble-wrap'. Although the emissivity of such surfaces is almost negligible in the thermal infrared, typically less than 0.03, an insufficiently thick metal coating, or organic contamination of the surface, can significantly increase this value. To ensure that the quality of the installed insulation is satisfactory, Australian building code AS/NZS 4201.5:1994 requires a practical agreed method for measurement of the emissivity, and the standard ASTM-E408 is implied. Unfortunately this standard is not a 'primary method' and requires the use of specified expensive apparatus and calibrated reference materials. At NMIA we have developed a simple primary technique, based on an apparatus to thermally modulate the sample and record the apparent modulation in infra-red radiance with commercially available radiation thermometers. The method achieves an absolute accuracy in the emissivity of approximately 0.004 (k=2). This paper theoretically analyses the equivalence between the thermal emissivity measured in this manner, the effective thermal emissivity in application, and the apparent emissivity measured in accordance with ASTM-E408.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Projection imaging of photon beams by the Cerenkov effect

Purpose: A novel technique for beam profiling of megavoltage photon beams was investigated for the first time by capturing images of the induced Cerenkov emission in water, as a potential surrogate for the imparted dose in irradiated media. Methods: A high-sensitivity, intensified CCD camera (ICCD) was configured to acquire 2D projection images of Cerenkov emission from a 4 Multiplication-Sign 4 cm{sup 2} 6 MV linear accelerator (LINAC) x-ray photon beam operating at a dose rate of 400 MU/min incident on a water tank with transparent walls. The ICCD acquisition was gated to the LINAC sync pulse to reduce background light artifacts, and the measurement quality was investigated by evaluating the signal to noise ratio and measurement repeatability as a function of delivered dose. Monte Carlo simulations were used to derive a calibration factor for differences between the optical images and deposited dose arising from the anisotropic angular dependence of Cerenkov emission. Finally, Cerenkov-based beam profiles were compared to a percent depth dose (PDD) and lateral dose profile at a depth of d{sub max} from a reference dose distribution generated from the clinical Varian ECLIPSE treatment planning system (TPS). Results: The signal to noise ratio was found to be 20 at a delivered dose of 66.6 cGy, and proportional to the square root of the delivered dose as expected from Poisson photon counting statistics. A 2.1% mean standard deviation and 5.6% maximum variation in successive measurements were observed, and the Monte Carlo derived calibration factor resulted in Cerenkov emission images which were directly correlated to deposited dose, with some spatial issues. The dose difference between the TPS and PDD predicted by Cerenkov measurements was within 20% in the buildup region with a distance to agreement (DTA) of 1.5-2 mm and {+-}3% at depths beyond d{sub max}. In the lateral profile, the dose difference at the beam penumbra was within {+-}13% with a DTA of 0-2 mm, {+-}5% in the central beam region, and 2%-3% in the beam umbra. Conclusions: The results from this initial study demonstrate the first documented use of Cerenkov emission imaging to profile x-ray photon LINAC beams in water. The proposed modality has several potential advantages over alternative methods, and upon future refinement may prove to be a robust and novel dosimetry method.

61 RADIATION PROTECTION AND DOSIMETRY↗

Constraints on the normal branch of DGP gravity from SPT galaxy clusters with DES and HST weak-lensing mass calibration and from P l a n c k PR4 CMB anisotropies

We present constraints on the normal branch of the Dvali-Gabadadze-Porrati (nDGP) braneworld gravity model from the abundance of massive galaxy clusters. On scales below the nDGP crossover scale r c , the nDGP model features an effective gravitylike fifth force that alters the growth of structure, leading to an enhancement of the halo mass function (HMF) on cluster scales. The enhanced cluster abundance allows for constraints on the nDGP model using cluster samples. We employ the South Pole Telescope (SPT) cluster sample, selected through the thermal Sunyaev-Zel’dovich effect with the SPT and with mass calibration using weak-lensing data from the Dark Energy Survey (DES) and the Hubble Space Telescope (HST). The cluster sample contains 1,005 clusters with redshifts 0.25 < z < 1.78 , which are confirmed with the multicomponent matched filter algorithm using optical and near-infrared data. Weak-lensing data from DES and HST enable a robust mass measurement of the cluster sample. We use DES Year 3 data for 688 clusters with redshifts z < 0.95 , and HST data for 39 clusters with redshifts 0.6 < z < 1.7 . We account for the enhancement in the HMF through a semi-analytic correction factor to the standard cosmology HMF derived from the spherical collapse model in the nDGP model. We then further calibrate this model using N -body simulations. In addition, for the first time, we analyze the primary CMB temperature and polarization anisotropy measurements from Planck PR4 within the nDGP model. We obtain a competitive constraint from the joint analysis of the SPT cluster abundance with the Planck PR4 data, and report an upper bound of 1 / H 0 r c < 1.41 at 95% when assuming a cosmology with massive neutrinos.

Vogt, S. M.L. [Munich U. Observ.; LMU Munich (main↗

Uncertainty guided online ensemble for non-stationary data streams in fusion science

Machine Learning (ML) is poised to play a pivotal role in the development and operation of next-generation fusion devices. Fusion data shows non-stationary behavior with distribution drifts, resulted by both experimental evolution and machine wear-and-tear. ML models assume stationary distribution and fail to maintain performance when encountered with such non-stationary data streams. Online learning techniques have been leveraged in other domains, however it has been largely unexplored for fusion applications. In this paper, we investigate online learning for continuous adaptation to drifting data streams in the prediction of Toroidal Field (TF) coils deflection at the DIII-D fusion facility. We further address the short-term performance degradation inherent to standard online learning, which arises because ground truth is unavailable at prediction time. To mitigate this issue, we propose an uncertainty-guided online ensemble framework. The method leverages the Deep Gaussian Process Approximation (DGPA) for calibrated uncertainty estimation and uses these uncertainty measures to guide a meta-algorithm that aggregates predictions from learners trained over different historical horizons. Our results show that online learning reduces prediction error by 80% compared to a static model. The online ensemble and the proposed uncertainty-guided ensemble further reduce error by approximately 6%, and 10% respectively, relative to standard single-model online learning, while also providing calibrated uncertainty estimates to support operational decision-making.

AI↗

Additive Manufacture of Plasma Diagnostic Components Final Report Phase II

There is now a well-established set of plasma diagnostics (see e.g. [3]), but these remain some of the most expensive assemblies in fusion systems since for every system they have to be custom built, and time for diagnostic development can pace the project. Additive manufacturing (AM) has the potential to decrease production cost and significantly lower design time of fusion diagnostic subsystems, which would realize significant cost reduction for standard diagnostics. In some cases, these basic components can be additively manufactured for less than 1/100th costs of conventional manufacturing.In our DOE Phase II SBIR, we examined the impact that AM can have on plasma diagnostic cost by taking 15 separate diagnostics through an engineering design using Conventional Manufacturing (CM) techniques, then optimizing the design to exploit the benefits of AM. The impact of AM techniques on cost is found to be in several areas. First, the cost of materials falls because AM parts can be manufactured with little to no waste, and engineered to use less material than CM. Next, the cost of fabrication falls for AM parts relative to CM since the fabrication time can be computed exactly, and often no post-processing is required for the part to be functional. We find that AM techniques are well suited for plasma diagnostics since typical diagnostic complexity comes at no additional cost. Cooling channels, for example, can be builtin to plasma-facing components at no extra cost. Fabrication costs associated with assembly are lower for AM parts because many components can be combined and printed as monoliths, thereby mitigating the need for alignment or calibration. Finally, the cost of engineering is impacted by exploiting AM design tools that allow standard components to be customized through web-interfaces. Furthermore, we find that concept design costs can be impacted by scripting interfaces for online engineering design tools.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of the Moessbauer Spectrum Quality as a Dependence on the Frequency of the Velocity Signal

This paper is focused on a quality characterizing the Moessbauer spectra measured for various frequencies of the velocity signal. Standard electromechanical double-loudspeaker drive and digital PID velocity controller were used for calibration spectra measurement in the frequency interval from 4 up to 100 Hz. Several parameters were evaluated for recommendation of the suitable velocity signal frequency.

07 ISOTOPE AND RADIATION SOURCES↗

Yield strength of CeO 2 measured from static compression in a radial diamond anvil cell

Cerium oxide (ceria, CeO 2 ) is frequently used as a standard in applications such as synchrotron and x-ray free electron lasers for calibrating x-ray wavelengths and offers the potential for understanding the high pressure properties and deformation mechanisms in a wide range of similar face centered cubic (fcc) materials. In this study, the pressure dependence of the strength of ceria was investigated up to 38 GPa using angle dispersive x-ray diffraction in a radial geometry in a diamond anvil cell. In this experiment, the difference in the stress along the axis of compression and perpendicular to the direction of compression can be determined, giving a quantity known as the differential stress. It was found that the differential stress (t), a measure of the lower bound for yield strength, initially increases rapidly from 0.35 ± 0.06 GPa to 2.2 ± 0.4 GPa at pressures of 1.8 and 3.8 GPa, respectively. Above 4 GPa, t increases more slowly to 13.8 ± 2.6 GPa at a pressure of 38 GPa. The changes in the preferred orientation (texture) of CeO 2 with pressure were also measured, allowing for the determination of active deformation mechanisms using an elasto-viscoplastic self-consistent model (EVPSC). It was found that as pressure increased, the [001] direction had a slight preferred orientation along the axis of compression. Our EVPSC model of experimental fiber (cylindrically symmetric) textures and lattice strains were most consistent with dominant slip activity along ${111}$ $\langle$$1\bar10$$\rangle$.

36 MATERIALS SCIENCE↗

VI-band follow-up observations of ultra-long-period Cepheid candidates in M31

The ultra-long-period Cepheids (ULPCs) are classical Cepheids with pulsation periods exceeding ≈80 days. The intrinsic brightness of ULPCs are ∼1 to ∼3 mag brighter than their shorter period counterparts. This makes them attractive in future distance scale work to derive distances beyond the limit set by the shorter period Cepheids. We have initiated a program to search for ULPCs in M31, using the single-band data taken from the Palomar Transient Factory, and identified eight possible candidates. In this work, we presented the VI-band follow-up observations of these eight candidates. Based on our VI-band light curves of these candidates and their locations in the color–magnitude diagram and the Period–Wesenheit diagram, we verify two candidates as being truly ULPCs. The six other candidates are most likely other kinds of long-period variables. With the two confirmed M31 ULPCs, we tested the applicability of ULPCs in distance scale work by deriving the distance modulus of M31. It was found to be μ{sub M31,ULPC}=24.30±0.76 mag. The large error in the derived distance modulus, together with the large intrinsic dispersion of the Period–Wesenheit (PW) relation and the small number of ULPCs in a given host galaxy, means that the question of the suitability of ULPCs as standard candles is still open. Further work is needed to enlarge the sample of calibrating ULPCs and reduce the intrinsic dispersion of the PW relation before re-considering ULPCs as suitable distance indicators.

79 ASTRONOMY AND ASTROPHYSICS↗

Canopy reflectance spectra and photographs (raw data), Seward Peninsula, Alaska, 2022

Measurements of full-range (350–2500 nm) canopy spectral reflectance of Arctic plant species, plots, and transects at the Next Generation Ecosystem Experiment Arctic (NGEE Arctic) Teller Mile Marker (MM27) and Kougarok Fire Complex (KFC) sites, Seward Peninsula, Alaska. Spectra were collected in July 2022 using a handheld SVC HR-2014i spectroradiometer. All spectra were collected as calibrated surface radiance and converted to surface reflectance using 99.99% reflective Spectralon white reference standard. This data package includes unprocessed instrument output of the spectra signals (.sig) and, for some canopy measurements, photographs of the target taken by the SVC instrument camera or handheld digital camera (.jpg), GPS locations and file metadata (.csv).The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a 15-year research effort (2012-2027) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Rapid Analysis of Ash Composition Using Laser-Induced Breakdown Spectroscopy (LIBS)

Inorganic compounds are known to be problematic in the thermochemical conversion of biomass to syngas and ultimately hydrocarbon fuels. The elements Si, K, Ca, Na, S, P, Cl, Mg, Fe, and Al are particularly problematic and are known to influence reaction pathways, contribute to fouling and corrosion, poison catalysts, and impact waste streams. Substantial quantities of inorganic species can be entrained in the bark of trees during harvest operations. Herbaceous feedstocks often have even greater quantities of inorganic constituents, which can account for as much as one-fifth of the total dry matter. Current methodologies to measure the concentrations of these elements, such as inductively coupled plasma-optical emission spectrometry/mass spectrometry (ICP-OES/MS) are expensive in time and reagents. This study demonstrates that a new methodology employing laser-induced breakdown spectroscopy (LIBS) can rapidly and accurately analyze the inorganic constituents in a wide range of biomass materials, including both woody and herbaceous examples. This technique requires little or no sample preparation, does not consume any reagents, and the analytical data is available immediately. In addition to comparing LIBS data with the results from ICP-OES methods, this work also includes discussions of sample preparation techniques, calibration curves for interpreting LIBS spectra, minimum detection limits, and the use of internal standards and standard reference materials.

09 BIOMASS FUELS↗

Uncertainty Estimates for SIRS, SKYRAD, & GNDRAD Data and Reprocessing the Pyrgeometer Data (Presentation)

The National Renewable Energy Laboratory (NREL) and the Atmospheric Radiation Measurement (ARM) Climate Research Facility work together in providing data from strategically located in situ measurement observatories around the world. Both work together in improving and developing new technologies that assist in acquiring high quality radiometric data. In this presentation we summarize the uncertainty estimates of the ARM data collected at the ARM Solar Infrared Radiation Station (SIRS), Sky Radiometers on Stand for Downwelling Radiation (SKYRAD), and Ground Radiometers on Stand for Upwelling Radiation (GNDRAD), which ultimately improve the existing radiometric data. Three studies are also included to show the difference between calibrating pyrgeometers (e.g., Eppley PIR) using the manufacturer blackbody versus the interim World Infrared Standard Group (WISG), a pyrgeometer aging study, and the sampling rate effect of correcting historical data.

14 SOLAR ENERGY↗

Testing a Model of Planck-Scale Quantum Geometry With Broadband Correlation of Colocated 40m Interferometers

The Holometer is designed to test for a Planck diffractive-scaling uncertainty in long-baseline position measurements due to an underlying noncommutative geometry normalized to relate Black hole entropy bounds of the Holographic principle to the now-finite number of position states. The experiment overlaps two independent 40 meter optical Michelson interferometers to detect the proposed uncertainty as a common broadband length fluctuation. 150 hours of instrument cross-correlation data are analyzed to test the prediction of a correlated noise magnitude of $7\times10^{−21}$ m/$\sqrt{\rm Hz}$ with an effective bandwidth of 750kHz. The interferometers each have a quantum-limited sensitivity of $2.5\times 10^{−18}$ m/$\sqrt{\rm Hz}$, but their correlation with a time-bandwidth product of $4\times 10^{11}$ digs between the noise floors in search for the covarying geometric jitter. The data presents an exclusion of 5 standard deviations for the tested model. This exclusion is defended through analysis of the calibration methods for the instrument as well as further sub shot noise characterization of the optical systems to limit spurious background-correlations from undermining the signal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiometric correction procedure study

A comparison of MSS radiometric processing techniques identified as a preferred radiometric processing technique a procedure which equalizes the mean and standard deviation of detector-specific histograms of uncalibrated scene data. Evaluation of MSS calibration data demonstrated that the relationship between detector responses is essentially linear over the range of intensities typically observed in MSS data, and that the calibration wedge data possess a high degree of temporal stability. An analysis of the preferred radiometric processing technique showed that it could be incorporated into the MDP-MSS system without a major redesign of the system, and with minimal impact on system throughput.

Colby, C.↗

GEOS 3 ocean geoid investigation

A determination of the fine-scale sea surface topography in the GEOS 3 calibration area using the radar altimeter data is presented. Estimates of the north-south and east-west components of the deflections of the vertical as well as values of the geoidal heights are made. Three major stages of processing are used in obtaining the final results. The first two use pass processors; in the final stage the processor combines all the pass results to compute the final results. Comparison with a gravimetrically determined geoid for the calibration area, provided by the National Aeronautics and Space Administration, yielded a mean and standard deviation of 0.45 and 1.5 m, respectively

Yionoulis, S. M.↗

A miniaturized digital telemetry system for physiological data transmission

A physiological date telemetry system, consisting basically of a portable unit and a ground base station was designed, built, and tested. The portable unit to be worn by the subject is composed of a single crystal controlled transmitter with AM transmission of digital data and narrowband FM transmission of voice; a crystal controlled FM receiver; thirteen input channels follwed by a PCM encoder (three of these channels are designed for ECG data); a calibration unit; and a transponder control system. The ground base station consists of a standard telemetry reciever, a decoder, and an FM transmitter for transmission of voice and transponder signals to the portable unit. The ground base station has complete control of power to all subsystems in the portable unit. The phase-locked loop circuit which is used to decode the data, remains in operation even when the signal from the portable unit is interrupted.

Portnoy, W. M.↗