Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Electron Cyclotron Heating system status and upgrades on DIII-D

The Electron Cyclotron Heating (ECH) system on the DIII-D tokamak consists of six 110 GHz gyrotrons with corrugated coaxial 31.75 mm waveguide transmission lines and steerable launching mirrors. The system has been gradually updated, leading to increased experimental flexibility and a high system reliability of 91% in the past year. Operationally, the gyrotrons can generate up to a total of 4.8 MW of rf power for pulses up to 5 seconds in length. The maximum ECH energy injected into the DIII-D has been 16.6 MJ. The HE11 mode content is over 85% for all the lines, and the transmission coefficient is better than -1.1 dB for all the transmission lines, close to the theoretical value. A new depressed collector gyrotron was recently installed and was injecting up to 640 kW of power into the plasma during 2014-2015 tokamak operations. Three dual waveguide launchers, which can steer the RF beams ±20 degrees poloidally and toroidally, were used for real-time neoclassical tearing mode control and suppression. The launchers now have increased poloidal scanning speed and beam positioning accuracy of ~±2 mm at the plasma center. A new method of in-situ calibration of the mirror angle was used in conjunction with the upgrading of the encoders and motors for the launchers. Two more gyrotrons are expected to be installed and operational in 2015-2016. The first is a repaired 110 GHz, 1 MW gyrotron that had a gun failure after more than 11 years of operation at DIII-D. The second is a newly designed depressed collector tube in the 1.5 MW class, operating at 117.5 GHz, manufactured by Communications and Power Industries (CPI). It operates in the TE20,9 mode and has achieved 1.8 MW for short pulses during factory testing. Furthermore, this gyrotron is undergoing rework to address a high voltage standoff problem.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Poster — Thur Eve — 23: Dose and Position Quality Assurance using the RADPOS System for 4D Radiotherapy with CyberKnife

Introduction: RADPOS 4D dosimetry system consists of a microMOSFET dosimeter combined with an electromagnetic positioning sensor, which allows for performing real-time dose and position measurements simultaneously. In this report the use of RADPOS as an independent quality assurance (QA) tool during CyberKnife 4D radiotherapy treatment is described. In addition to RADPOS, GAFCHROMIC® films were used for simultaneous dose measurement. Methods: RADPOS and films were calibrated in a Solid Water® phantom at 1.5 cm depth, SAD= 80 cm, using 60 mm cone. CT based treatment plan was created for a Solid Water® breast phantom containing metal fiducials and RADPOS probe. Dose calculations were performed using iPlan pencil beam algorithm. Before the treatment delivery, GAFCHROMIC® film was inserted inside the breast phantom, next to the RADPOS probe. Then the phantom was positioned on the chest platform of the QUASAR, to which Synchrony LED optical markers were also attached. Position logging began for RADPOS and the Synchrony tracking system, the QUASAR motion was initiated and the treatment was delivered. Results: RADPOS position measurements very closely matched the LED marker positions recorded by the Synchrony camera tracking system. The RADPOS measured dose was 2.5% higher than the average film measured dose, which is within the experimental uncertainties. Treatment plan calculated dose was 4.1 and 1.6% lower than measured by RADPOS and film, respectively. This is most likely due to the inferior nature of the dose calculation algorithm. Conclusions: Our study demonstrates that RADPOS system is a useful tool for independent QA of CyberKnife treatments.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-323: A Post-Mastectomy Radiation Therapy Dose Distribution Study Using Nanodots and Films

Purpose: In post-mastectomy radiation therapy (RT), skin dose must be accurately estimated to assess skin reactions such as erythema, desquamation and necrosis. Planning systems cannot always provide accurate dosimetry for target volumes distal to skin. Therefore, in-vivo dosimetry is necessary. A female anthropomorphic phantom was used with optically stimulated luminescence dosimeters (nanoDots) to measure dose to chest wall skin. In addition, EBT2 films was employed to measure dose to left lung and heart in post-mastectomy RT. Methods: Films and nanoDots were calibrated under full buildup conditions at 100cm SAD for 6MV photons. Five pieces of films were placed between slabs of Rando phantom to assess dose to left lung and heart. Two layers of 0.5cm thick bolus were used to cover the whole left chest. Six pairs of nanoDots were placed at medical and lateral aspects on the bolus surface, between the 0.5cm bolus layers, and under the bolus. Three control nanoDots were placed on chest wall to quantify imaging dose. The phantom was CT scanned with all dosimeters in place, and treatment planning was performed with tangential fields (200cGy). All dosimeters were contoured on CT and dose was extracted. NanoDots were read using nanoDot reader and films were scanned using film scanner. The measured and calculated doses were tabulated. Results: Dose to 12 nanoDots were evaluated. Dose variance for surface nanoDots were +3.8%, +2.7%, −5% and −9.8%. Those at lateral positions, with greater beam obliquity had larger variance than the medial positions. A similar trend was observed for other nanoDots (Table1). Point doses from films for heart and the left lung were 112.7cGy and 108.7cGy, with +10.2% and +9.04% deviation from calculated values, respectively. Conclusion: Dosimetry provided by the advanced planning system was verified using NanoDots and films. Both nanoDots and films provided good estimation of dose distribution in post-mastectomy RT.

60 APPLIED LIFE SCIENCES↗

Dual-mode fiber-optic refractive-index gas thermometry with primary anchoring and continuous temperature tracking

Extending fiber-optic refractive-index gas thermometry beyond primary-only operation, we report a dual-mode argon-filled Fabry-Perot thermometer in which the same cavity first establishes a primary temperature anchor and then performs continuous secondary-mode tracking. The primary anchor is obtained from two-pressure fringe shifts using a virial-coefficient refractivity model. During secondary operation, pressure cycling is stopped, and temperature is recovered from the monitored fringe wavelength and gas pressure using a model that includes argon refractivity, pressure-induced cavity strain, and fused-silica thermal expansion. From 310 to 1013 K, secondary-mode temperatures agreed with a reference thermocouple with 0.21 K RMSE and 0.47 K maximum error; 45-min natural furnace cooldowns were also tracked from nearby anchors with close agreement. The dual-mode method retains the empirical-calibration-free primary measurement as an in-situ reference while enabling simpler continuous tracking between anchors, addressing a practical limitation of primary-only fiberoptic refractive-index gas thermometry for hightemperature applications.

Syed, Musaddeque [Michigan State University, East ↗

Spectroscopic Investigation of p-Shell Lambda Hypernuclei by the (e,e'K + ) Reaction

Hypernuclear spectroscopy is a powerful tool to investigate Lambda-N interaction. Compared with other Lambda hypernuclei productions, electroproduction via the (e,e'K+) reaction has the advantage of exciting states deeply inside of the hypernucleus and achieving sub-MeV energy resolution. The E05-115 experiment, which was successfully performed in 2009, is the third generation hypernuclear experiment in JLab Hall C. A new splitter magnet and electron spectrometer were installed, and beam energy of 2.344 GeV was selected in this experiment. These new features gave better field uniformity, optics quality and made the tilt method more effective in improving yield-to-background ratio. The magnetic optics of the spectrometers were carefully studied with GEANT simulation, and corrections were applied to compensate for the fringe field cross talk between the compact spectrometer magnets. The non-linear least chi-squared method was used to further calibrate the spectrometer with the events from Lambda, Sigma0 and B12Lambda and uniform magnetic optics as well as precise kinematics were achieved. Several p-shell Lambda hypernuclear spectra, including B 12 Λ , Be 10 Λ , He 7 Λ , were obtained with high energy resolution and good accuracy. For B 12 Λ , eight peaks were recognized with the resolution of ~540keV (FWHM), and the ground state binding energy was obtained as 11.529 ± 0.012(stat.) ± 0.110(syst.) MeV. Be 10 Λ , twelve peaks were recognized with the resolution of ~520keV (FWHM), and the binding energy of the ground state was determined as 8.710 ± 0.059(stat.) ± 0.114(syst.) MeV. For He 7 Λ , three peaks were recognized with the resolution of ~730keV, and the ground state binding energy was obtained as 5.510 ± 0.050(stat.) ± 0.120(syst.) MeV. Compared with the published data of B 12 Λ from the JLab Hall A experiment, four extra peaks were fitted and interpreted thanks to the highest ever energy resolution and sufficient statistics. The determined binding energy of Be 10 Λ provides new information on charge symmetry breaking effect in the Lambda-N interaction. Compared with the results of He7Lambda from the E01-011 experiment, the ground state position is consistent with 4 times more statistics, and two extra peaks corresponding to excited states were recognized.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Transport Equation Approach to Modeling the Influence of Surface Roughness on Boundary Layer Transition

A computational investigation has been performed to better understand the impact of surface roughness on the flow over a contaminated surface. This report highlights the implementation and development of the roughness amplication model in the flow solver OVER FLOW-2. The model, originally proposed by Dassler, Kozulovic, and Fiala, introduces an additional scalar field roughness amplification quantity. This value is explicitly set at rough wall boundaries using surface roughness parameters and local flow quantities. The additional transport equation allows non-local effects of surface roughness to be accounted for downstream of rough sections. This roughness amplification variable is coupled with the Langtry-Menter model and used to modify the criteria for transition. Results from at plate test cases show good agreement with experimental transition behavior on the flow over varyings and grain roughness heights. Additional validation studies were performed on a NACA 0012 airfoil with leading edge roughness. The computationally predicted boundary layer development demonstrates good agreement with experimental results. New tests using varying roughness configurations have been carried out at the Texas A&M Oran W. Nicks Low Speed Wind Tunnel to provide further calibration of the roughness amplification method. An overview and preliminary results are provided of this concurrent experimental investigation.

17 WIND ENERGY↗

Multiscale Approach to Fast ModSim for Laser Processing of Metals for Future Nuclear Deterrence Environments

Predicting performance of parts produced using laser-metal processing remains an out- standing challenge. While many computational models exist, they are generally too computationally expensive to simulate the build of an engineering-scale part. This work develops a reduced order thermal model of a laser-metal system using analytical Green's function solutions to the linear heat equation, representing a step towards achieving a full part performance prediction in an "overnight" time frame. The developed model is able to calculate a thermal history for an example problem 72 times faster than a traditional FEM method. The model parameters are calibrated using a non-linear solution and microstructures and residual stresses calculated and compared to a non-linear case. The calibrated model shows promising agreement with a non-linear solution.

36 MATERIALS SCIENCE↗

Applications of Alternate Actinide Calibration on Inductively Coupled Plasma Mass Spectrometry (ICPMS) Analysis of H-Canyon Highly Enriched Uranium Legacy Material at the Savannah River Site (SRS)

The Savannah River National Laboratory (SRNL) uses Inductively Coupled Plasma Mass Spectrometry (ICPMS) to support numerous programs at the Savannah River Site (SRS). As part of an objective to prepare high assay low enriched uranium (HALEU), the SRS H-Canyon needed analysis of legacy uranyl nitrate that is stored at its Outside Facilities (HOF). With the application of a standard practice for alternate actinide calibration on ICP-MS, SRNL has successfully demonstrated its capability to characterize the uranium/actinide composition of the HOF tanks that are intended for consolidation prior to preparation of the HALEU. A comparison of the uranium analytical results between recently upgraded SRNL ICP-MS and Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) instrumentation shows the alternate actinide calibration is a valid complementary method when used in conjunction with other analytical techniques (Davies-Gray Potentiometric Titration). The methods, instrumentation, and ongoing developments on ICP-MS at SRNL will be discussed.

Jones, Mark A.↗

Measuring Light Yield with Isolated Protons in MicroBooNE

Liquid Argon Time Projection Chambers (LArTPCs) are precision detectors used extensively in neutrino physics. The MicroBooNE experiment at Fermilab is one of the experiments employing this technique and has collected 5 years of data from 2015-2021. The primary signal in LArTPCs is ionisation, but argon also emits large quantities of scintillation light, which can be used for calorimetry, timing and background rejection. Prompt scintillation light in MicroBooNE is recorded with an array of 32 PhotoMultiplier Tubes (PMTs). To enable the full use of scintillation light in the experiment, it is important to characterize the efficiency of light collection in the detector, i.e. the light yield. We present a new method of measuring the light yield using isolated proton interactions, which enables a position-dependent light yield measurement to map the response of the detector across its volume. This method can be used to calibrate the light response in large-scale LArTPC detectors as well as to test assumptions used in simulating scintillation light.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

User Guide for Sample Reduction at GP-SANS

This manual is intended as a quick guide for data reduction of GP-SANS data. It includes all necessary steps to do the data reduction based on absolute calibration using the open beam method and how to transfer the reduced data to the personal computer system. If any errors are coming up so that the reduction script is not functioning as intended, please contact the instrument scientist.

97 MATHEMATICS AND COMPUTING↗

Finding Peas in the Early Universe with JWST

The Early Release Observations (EROs) of JWST beautifully demonstrate the promise of JWST in characterizing the universe at Cosmic Dawn. We analyze the Near Infrared Spectrograph ERO spectra of three z ~ 8 galaxies to determine their metallicities, gas temperatures, and ionization. These galaxies offer the first opportunity to understand the physical properties of Epoch-of-Reionization galaxies through detailed rest-optical emission-line spectroscopy. We show that these objects have metal abundances $12+\mathrm{log}[{\rm{O}}/{\rm{H}}]\,\approx$ 6.9–8.3, based on both the T e method and on a recent calibration of the R 23 metallicity indicator. Since the spectra are some of the earliest science data from JWST, we compare several line ratios with values expected from robust physics, to validate our measurement procedures. We compare the abundances and emission-line ratios to a nearby sample of Green Pea galaxies—a population of nearby emission-line galaxies whose UV properties resemble Epoch-of-Reionization galaxies, and which often have large Lyman continuum escape fractions. The JWST data show striking further similarities between these high-redshift galaxies and nearby Green Peas. The z ~ 8 galaxies span the metallicity range covered by Green Peas. They also show the compact morphology that is typical of emission-line-dominated galaxies at all redshifts. Based on these similarities with Green Peas, it is likely that these are the first rest-optical spectra of galaxies that are actively driving cosmological reionization.

79 ASTRONOMY AND ASTROPHYSICS↗

Direct reading of electrocardiograms and respiration rates

Technique for reading heart and respiration rates is more accurate and direct than the previous method. Index of a plastic calibrated card is aligned with a point on the electrocardiogram. Complexes are counted as indicated on the card and heart or respiration rate is read directly from the appropriate scale.

Wise, J. P.↗

Application of remotely sensed multispectral data to automated analysis of marshland vegetation. Inference to the location of breeding habitats of the salt marsh mosquito (Aedes Sollicitans)

The techniques used for the automated classification of marshland vegetation and for the color-coded display of remotely acquired data to facilitate the control of mosquito breeding are presented. A multispectral scanner system and its mode of operation are described, and the computer processing techniques are discussed. The procedures for the selection of calibration sites are explained. Three methods for displaying color-coded classification data are presented.

Cibula, W. G.↗

Angiocardiography - Past and present

Angiocardiography is defined as an X-ray procedure which uses an intravascularly injected contrast material for visualization of the internal anatomy of the heart and great vessels. Past and present efforts in angiocardiography technology and methodology are reviewed, with special emphasis on qualitative and quantitative measurements of heart and vessel geometry. One of the more recent applications of angiographic image analysis has been for pattern recognition of margin motions over a cardiac cycle, termed contourography. Angiocardiography will continue to serve, as it has served in the past, as the principal standard of reference for calibration and/or comparison of newer methods for determining volume or dimensional change, depending on further technologic advances in X-ray equipment and means for displaying computer-processed information.

Sandler, H.↗

Pressure measurement at low temperatures

The present discussion centers on the following topics: (1) what types of pressure transducers show good potential for cryogenic use; (2) what are the output characteristics (stability, sensitivity, etc.) of a transducer when subjected to low temperature environments; and (3) are methods or apparatus available to calibrate cryogenically pressure transducers under static and dynamic conditions. Some information is available on the low-temperature performance of relatively few pressure transducer types; however, the information is either in the form of manufacturing specifications or unpublished reports. The results of this study clearly indicate that individual transducers, even from the same manufacturer, can exhibit totally different characteristics when subjected to identical cryogenic test procedures. This indicates the necessity of calibrating each transducer for use at low temperature. Also included in the discussion is the description of a static/dynamic low-temperature pressure transducer calibration facility, which is currently being developed.

Arvidson, J. M.↗

Recent progress of the research work on frequency and time at the NIM

Chinese activities reported include (1) research and development on the primary cesium beam standard and the high precision crystal oscillator; (2) keeping the atomic time and calibrating frequency standards; (3) determining methods for transferring the standard frequency at the highest precision. The primary beam installation gives an accuracy of 1.2 x 10 to the minus 12 power (1 sigma). Improvements are being made to attain an uncertainity goal of the order of 10 to the minus 13 power. Two experiments conducted are described. One involved standard frequency transfer via TV color subcarrier; the other involved time synchronization via Symphonie satellite. The best results are the random fluctuation of direct measurement data is 1 sigma sub r (RMS) 10 ns, and the absolute error of clock synchronization is 1 sigma sub A (RMS) 30 ns.

Bingying, H.↗

Solar ultraviolet spectral irradiance monitor experiment on OSS-1

The need to improve the accuracy of measurement of the absolute solar flux within the wavelength range 120 nm to 400 nm requires an extensive effort in contamination control and in tracking the instruments' stability. The techniques used in the solar ultraviolet irradiance monitor are described. These methods resulted in very high calibration stability as proved by preflight and postflight calibration. In-flight calibrating and the pointing accuracy provided by the shuttle attitude control system are discussed.

Vanhossier, M. E.↗