Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data Digitization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Remote sensing of wetlands

Results are given for three separate investigations of remote sensing over wetlands, including the delineations of roseau cane and mangrove from both Landsat and aircraft MSS data, and the delineation of wetland communities for potential waste assimilation in a coastal river floodplain from Landsat MSS data only. Attention is also given to data processing and analysis techniques of varying levels of sophistication, which must increase with surface cover diversity. All computer processing in these studies was performed on a minicomputer configured with the adequate memory, image display capability, and associated peripherals, using state-of-the-art digital MSS data analysis software.

Butera, M. K.↗

ALDAS user's manual

The Acoustic Laboratory Data Acquisition System (ALDAS) is an inexpensive, transportable means to digitize and analyze data. The system is based on the Macintosh 2 family of computers, with internal analog-to-digital boards providing four channels of simultaneous data acquisition at rates up to 50,000 samples/sec. The ALDAS software package, written for use with rotorcraft acoustics, performs automatic acoustic calibration of channels, data display, two types of cycle averaging, and spectral amplitude analysis. The program can use data obtained from internal analog-to-digital conversion, or discrete external data imported in ASCII format. All aspects of ALDAS can be improved as new hardware becomes available and new features are introduced into the code.

Watts, Michael E.↗

A video event trigger for high frame rate, high resolution video technology

When video replaces film the digitized video data accumulates very rapidly, leading to a difficult and costly data storage problem. One solution exists for cases when the video images represent continuously repetitive 'static scenes' containing negligible activity, occasionally interrupted by short events of interest. Minutes or hours of redundant video frames can be ignored, and not stored, until activity begins. A new, highly parallel digital state machine generates a digital trigger signal at the onset of a video event. High capacity random access memory storage coupled with newly available fuzzy logic devices permits the monitoring of a video image stream for long term or short term changes caused by spatial translation, dilation, appearance, disappearance, or color change in a video object. Pretrigger and post-trigger storage techniques are then adaptable for archiving the digital stream from only the significant video images.

Williams, Glenn L.↗

Systems and methods for self-synchronized digital sampling

Systems and methods for self-synchronized data sampling are provided. In one embodiment, a system for capturing synchronous data samples is provided. The system includes an analog to digital converter adapted to capture signals from one or more sensors and convert the signals into a stream of digital data samples at a sampling frequency determined by a sampling control signal; and a synchronizer coupled to the analog to digital converter and adapted to receive a rotational frequency signal from a rotating machine, wherein the synchronizer is further adapted to generate the sampling control signal, and wherein the sampling control signal is based on the rotational frequency signal.

Samson, Jr., John R.↗

Crack Detection for Aerospace Quality Spur Gears

Health and Usage Monitoring System research and development involves analysis of the vibration signals produced by a gearbox throughout its life. There are two major advantages of knowing the actual lifetime of a gearbox component: safety and cost. In this report, a technique is proposed to help extract the critical data and present it in a manner that can be easy to understand. The key feature of the technique is to make it independent of speed, torque and prior history for localized, single tooth damage such as gear cracks. This extraction technique is demonstrated on two sets of digitized vibration data from cracked spur gears. Standard vibration diagnostic parameters are calculated and presented for comparison. Several new detection algorithms are also presented. The results of this study indicate that crack detection methods examined are not robust or repeatable. The proposed techniques provide a limited improvement to existing diagnostic parameters. Current techniques show that the cracks progressed at a much faster rate than anticipated which reduced available time for detection.

Decker, Harry J.↗

NASA Near Earth Network (NEN) DVB-S2 Demonstration Testing for Enhancing Higher Data Rates for CubeSat/Small Satellite Missions at X-/Ka-band

National Aeronautics and Space Administration (NASA) CubeSat/SmallSat missions are moving to higher data rates. Digital Video Broadcast, Satellite Second Generation (DVB-S2) is a communications standard that uses power and bandwidth efficient modulation and coding techniques to deliver performance approaching radio frequency (RF) channel theoretical limits. The Near Earth Network (NEN) will test DVB-S2’s ability to provide higher data rates for CubeSat/SmallSat missions at X-band and Ka-band at Wallops Flight Facility (WFF). The goal is to upgrade the NEN with DVB-S2 to increase science data return for missions and enable support for more CubeSat/SmallSat missions. This paper describes NEN DVB-S2 X-band and Ka-band demonstration objectives, scope, and performance measures as well as NEN channel test configuration. The NEN has planned 2020 tests to demonstrate all modulation and coding schemes in the Consultative Committee for Space Data Systems (CCSDS) DVB-S2 standard over X-band and Ka-band. A link analysis study for the trade-offs among achievable data rates, modulations, codes, spacecraft antenna sizes and power amplifiers (PA) is provided. This paper identifies Commercial off-the-shelf (COTS) CubeSat/SmallSat X-band and Ka-band communication systems and discusses low cost DVB-S2 X-band software defined radio (SDR) transmitter development concepts and implementation with a practical system for CubeSats/SmallSats.

Yen Wong↗

Cyber security using multi-threaded architecture data diode at the NBSR - 114

Ongoing upgrades for the control room of the National Bureau of Standards Reactor (NBSR) located at the National Institute of Standards and Technology (NIST) require the ability to collect sensor data from the secured reactor network and transfer to the outside network for trend analysis, while maintaining the security of the reactor network. To accomplish this, a data diode was created to provide a physical barrier that prevents any outside data from reaching the secured reactor network. The hardware of the data diode consists of two embedded computers, running Unix based operating systems, connected by three DB-9 serial cables. The serial cables have been modified so that only two wires, a ground and a transmission line, provide connection between the computers. The data diode relies on a multi-threaded architecture to collect and simultaneously transfer data over three serial connections. A software program, implemented in Java, has been written to request data from the digital recorders installed to monitor the NBSR process instrumentation and transfer that data across the serial connections. The data diode can collect over 1200 data points from multiple digital recorders each second. The collected data can then be stored in a relational database for later analysis. The source codes for the software are available open source on GitHub. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A global model of carbon-nutrient interactions

The global biogeochemical model presented has two primary objectives. First, it characterizes natural elemental cycles and their linkages for the four elements significant to Earth's biota: C, N, S, and P. Second, it describes changes in these cycles due to human activity. Global nutrient cycles were studied within the drainage basins of several major world rivers on each continent. The initial study region was the Mississippi drainage basin, concentrating on carbon and nitrogen. The model first establishes the nutrient budgets of the undisturbed ecosystems in a study region. It then uses a data set of land use histories for that region to document the changes in these budgets due to land uses. Nutrient movement was followed over time (1800 to 1980) for 30 ecosystems and 10 land use categories. A geographically referenced ecological information system (GREIS) was developed to manage the digital global data bases of 0.5 x 0.5 grid cells needed to run the model: potential vegetation, drainage basins, precipitation, runoff, contemporary land cover, and FAO soil maps of the world. The results show the contributions of land use categories to river nutrient loads on a continental scale; shifts in nutrient cycling patterns from closed, steady state systems to mobile transient or open, steady state systems; soil organic matter depletion patterns in U.S. agricultural lands; changing nutrient ratios due to land use changes; and the effect of using heavy fertilizer on aquatic systems.

Moore, Berrien, III↗

Mathematical modeling and SAR simulation multifunction SAR technology efforts

The orbital SAR (synthetic aperture radar) simulation data was used in several simulation efforts directed toward advanced SAR development. Efforts toward simulating an operational radar, simulation of antenna polarization effects, and simulation of SAR images at serveral different wavelengths are discussed. Avenues for improvements in the orbital SAR simulation and its application to the development of advanced digital radar data processing schemes are indicated.

Griffin, C. R.↗

Space Archeology Overview at Gordion: 2010 to 2012

In fiscal years 2010, 2011, and 2012, Compton Tucker was the principal investigator of a NASA Space Archaeology project that worked at Gordion, in Central Turkey. Tucker was assisted by an excellent team of co-workers including Joseph Nigro and Daniel Slayback of Science Systems Applications Incorporated, Jenny Strum of the University of New Mexico, and Karina Yager, a post doctoral fellow at NASA/GSFC. This report summaries their research activities at Gordion for the field seasons of 2010, 2011, and 2012. Because of the possible use of our findings at Gordion for tomb robbing there and/or the encouragement of potential tomb robbers using our geophysical survey methods to locate areas to loot, we have not published any of our survey results in the open literature nor placed any of these results on any web sites. These 2010- 2012 survey results remain in the confidential archives of the University of Pennsylvania's University Museum of Archaeology and Anthropology, the group that leads the Gordion Excavation and Research Project. Excavations are planned for 2013 at Gordion, including several that will be based upon the research results in this report. The site of Gordion in central Turkey, famous as the home of King Midas, whose father's intricately tied knot gave the site its name, also served as the center of the Phrygian kingdom that ruled much of Central Anatolia in Asia Minor during the early first millennium B.C. Gordion has been a University of Pennsylvania Museum of Archaeology and Anthropology excavation project since 1950, yet the site is incompletely published despite six decades of research. The primary obstacles related to the site and its preservation were two problems that NASA technology could address: (1) critical survey errors in the hundreds of maps and plans produced by the earlier excavators, most of which used mutually incompatible geospatial referencing systems, that prevented any systematic understanding of the site; and (2) agricultural encroachment upon the site that was compromising its archaeological integrity. Our NASA Space Archaeology proposal was written to address both of these problems. When we started working at Gordion in 2010, we added a third objective, (3) ground penetrating radar and magnetic geophysical surveys of threatened areas. The first objective our NASA Space Archaeology Project was to provide the University of Pennsylvania's Museum of Archaeology and Anthropology a system to rectify and incorporate all existing survey data from Gordion, including previous aerial photographs of the site, detailed site surveys, maps, and excavation plans, into a common mapping system. This was accomplished with a Geographic Information System (GIS) based upon a 60 cm Quickbird satellite image ortho-rectified using Shuttle Radar Topographic Mission (SRTM) 30 m digital elevation data and tied to a known datum at Gordion. This enabled the first accurate, multi-layer plan of this complex site, occupied almost continuously from the Bronze Age to the 1st millennium CE, and made possible Gordion's three-dimensional development for the first time.

Gordion↗

TH-A-207B-00: Shear-Wave Imaging and a QIBA US Biomarker Update

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

TH-A-207B-01: Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

TH-A-207B-02: QIBA Ultrasound Elasticity Imaging System Biomarker Qualification and User Testing of Systems

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

Efficient detection, analysis and classification of lightning radiation fields

Modeling the large scale lightning flash structure is considered. Large scale flash data has been measured from strip charts of storms of August 5, August 26, and September 12, 1975. The data is being processed by a computer program called SASEV to estimate the large scale flash statistics. The program, experimental results, and conclusions for the large scale flash structure are described. The progress made in examining the internal flash structure consists mainly of developing the software required to process the NASA digital tape data. A FORTRAN program has been written for the statistical analysis of series of events. The statistics computed and tests performed are found to be particularly useful in the analysis of lightning data.

Harger, R. O.↗