Coca-Cola Refreshments Class 8 Diesel Electric Hybrid Tractor Evaluation: 13-Month Final Report

This 13-month evaluation used five Kenworth T370 hybrid tractors and five Freightliner M2106 standard diesel tractors at a Coca Cola Refreshments facility in Miami, Florida. The primary objective was to evaluate the fuel economy, emissions, and operational field performance of hybrid electric vehicles when compared to similar-use conventional diesel vehicles. A random dispatch system ensures the vehicles are used in a similar manner. GPS logging, fueling, and maintenance records and laboratory dynamometer testing are used to evaluate the performance of these hybrid tractors. Both groups drive similar duty cycles with similar kinetic intensity (0.95 vs. 0.69), average speed (20.6 vs. 24.3 mph), and stops per mile (1.9 vs. 1.5). The study demonstrated the hybrid group had a 13.7% fuel economy improvement over the diesel group. Laboratory fuel economy and field fuel economy study showed similar trends along the range of KI and stops per mile. Hybrid maintenance costs were 51% lower per mile; hybrid fuel costs per mile were 12% less than for the diesels; and hybrid vehicle total cost of operation per mile was 24% less than the cost of operation for the diesel group.

02 PETROLEUM↗

Light Water Reactor Sustainability Program Operator Performance Metrics for Control Room Modernization: A Practical Guide for Early Design Evaluation

As control rooms are modernized with new digital systems at nuclear power plants, it is necessary to evaluate the operator performance using these systems as part of a verification and validation process. There are no standard, predefined metrics available for assessing what is satisfactory operator interaction with new systems, especially during the early design stages of a new system. This report identifies the process and metrics for evaluating human system interfaces as part of control room modernization. The report includes background information on design and evaluation, a thorough discussion of human performance measures, and a practical example of how the process and metrics have been used as part of a turbine control system upgrade during the formative stages of design. The process and metrics are geared toward generalizability to other applications and serve as a template for utilities undertaking their own control room modernization activities.

99 GENERAL AND MISCELLANEOUS↗

Evaluation of COTS Rad Detection Apps

Mobile applications are currently under distribution to smart phones utilizing the built-in charge coupled-device (CCD) camera as a radiation detector. The CCD detector has a very low but measurable gamma interaction cross section so the mechanism is feasible, especially for higher dose rate environments. Given that in a large release of radioactive material these ‘crowd sourced’ measurements will be put forth for consideration, a testing and evaluation of the accuracy and uncertainty of the Apps is a critical endeavor. Not only is the accuracy of the reported measurement of concern to the immediate user’s safety, a quantitative uncertainty is required for a government response such as the Federal Radiological Monitoring and Assessment Center (FRMAC) to accept the values for consideration in the determination of regions exceeding protective action guidelines. Already, prompted by the Fukushima nuclear material releases, several repositories of this crowd-sourced data have been created (http://japan.failedrobot.com, http://www.stubbytour.com/nuc/index_en.asp, and http://www.rdtn.org) although the question remains as to the reliability of measurements incorporated into these repositories. In cases of conflict between the real-time published crowd-sourced data and governmental protective actions prepared literature should be on-hand documenting why the difference, if any, exists. Four applications for iOS devices were obtained along with hardware to benchmark their performance. Gamma/X-Ray Detector by Stephan Hotto, Geiger Camera by Senscare, and RadioactivityCounter App by Hotray LTD are all the applications available for distribution within the US that utilize the CCD camera sensor for detection of radiation levels. The CellRad app under development by Idaho National Laboratory for the Android platform was evaluated. In addition, iRad Geiger with the associated hardware accessory was also benchmarked. Radiation fields were generated in a Cs-137 JL Shepherd Model 89 shielded calibration range. The accuracy of the exposure rate within the box calibrator is +/- 5% of the system settings and NIST traceable. This is the same calibration unit utilized for calibration of US DOE exposure rate meters. Measurements were performed from 0.2 to 40,000 mR/hr. Included in the following sections are discussions on each of the evaluated applications and their performance in reporting radiation field measurements. Unfortunately the applications do not provide a readily identifiable quality of the measurement in order to produce error bars or even out of range conditions. In general all the CCD based applications had issues detecting consistent measurements in radiation fields less than 5 mR/hr. This is most likely attributable to the electronic noise level on the CCD’s becoming comparable to the signal level due to the ionizing radiation photons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Guide for Conducting Benefit-Cost Evaluation of Realized Impacts of Public R&D Programs

This document provides guidance for evaluators who conduct impact assessments to determine the “realized” economic benefits and costs, energy, environmental benefits, and other impacts of the Office of Energy Efficiency and Renewable Energy’s (EERE) R&D programs. The focus of this Guide is on realized outcomes or impacts of R&D programs actually experienced by American citizens, industry, and others. Retrospective evaluations may be contrasted to prospective evaluations that reflect expected or potential outcomes only if assumptions hold. The retrospective approach described in this Guide is based on realized results only and the extent they can be attributed to the efforts of an R&D program. While it has been prepared specifically to guide retrospective benefit-cost analysis of EERE R&D Programs, this report may be used for similar analysis of other public R&D organizations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Data Testing CIELO Evaluations with ICSBEP Benchmarks

We review criticality data testing performed at Los Alamos with a combination of ENDF/B-VII.1 + potential CIELO nuclear data evaluations. The goal of CIELO is to develop updated, best available evaluated nuclear data files for 1 H, 16 O, 56 Fe, 235,238 U and 239 Pu. because the major international evaluated nuclear data libraries don’t agree on the internal cross section details of these most important nuclides.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of Novel Wet Chemistry Separation and Purification Methods to Facilitate Automation of Astatine-­211 Isolation

This research is a collaborative effort between the research groups of the PIs, Dr. D. Scott Wilbur in the Department of Radiation Oncology at the University of Washington (UW) and Matthew O’Hara at the Pacific Northwest National Laboratory (PNNL). In this report only those studies conducted at UW and the budget information from UW will be reported. A separate progress and financial report will be provided by PNNL. This final report outlines the experiments (Tasks) conducted and results obtained at UW from July 1, 2013 thru June 30, 2016 (2-­year project with 1 year no-­cost extension). The report divides the information on the experiments and results obtained into the 5 specific objectives of the research efforts and the Tasks within those objectives. This format is used so that it is easy to see what has been accomplished in each area. A brief summary of the major findings from the studies is provided below. Summary of Major Findings from Research/Training Activities at UW: Anion and cation exchange columns did not provide adequate 211 At capture and/or extraction results under conditions studied to warrant further evaluation; PEG-­Merrifield resins containing mPEG350, mPEG750, mPEG2000 and mPEG5000 were synthesized and evaluated; All of the mPEG resins with different sized mPEG moieties conjugated gave similar 211 At capture (>95%) from 8M HCl solutions and release with conc. NH 4 OH (~50-­80%), but very low quantities were released when NaOH was used as an eluent; Capture and release of 211 At when loading [ 211 At]astatate appeared to be similar to that of [ 211 At]astatide on PEG columns, but further studies need to be conducted to confirm that; Capture of 211 At on PEG columns was lower (e.g. 80-­90%) from solutions of 8M HNO 3 , but higher capture rates (e.g. 99%) can be obtained when 10M HNO 3 is mixed with an equal quantity of 8M HCl; Addition of reductants to the 211 At solutions did not appear to change the percent capture, but may have an effect on the % extracted; There was some indication that the PEG-­Merrifield resins could be saturated (perhaps with Bi) resulting in lower capture percentages, but more studies need to be done to confirm that; A target dissolution chamber, designed and built at PNNL, works well with syringe pumps so it can be used in an automated system; Preliminary semi-­automated 211 At isolation studies have been conducted with full-scale target dissolution and 211 At isolation using a PEG column on the Hamilton automated system gave low overall recoveries, but HNO 3 was used (rather than HCl) for loading the 211 At and flow rates were not optimized; Results obtained using PEG columns are high enough to warrant further development on a fully automated system; Results obtained also indicate that additional studies are warranted to evaluate other types of columns for 211 At separation from bismuth, which allow use of HNO 3 /HCl mixtures for loading and NaOH for eluting 211 At. Such a column could greatly simplify the overall isolation process and make it easier to automate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental Design for Evaluating Selected Nondestructive Measurement Technologies - Advanced Reactor Technology Milestone: M3AT-16PN2301043

The harsh environments in advanced reactors (AdvRx) increase the possibility of degradation of safety-critical passive components, and therefore pose a particular challenge for deployment and extended operation of these concepts. Nondestructive evaluation technologies are an essential element for obtaining information on passive component condition in AdvRx, with the development of sensor technologies for nondestructively inspecting AdvRx passive components identified as a key need. Given the challenges posed by AdvRx environments and the potential needs for reducing the burden posed by periodic in-service inspection of hard-to-access and hard-to-replace components, a viable solution may be provided by online condition monitoring of components. This report identifies the key challenges that will need to be overcome for sensor development in this context, and documents an experimental plan for sensor development, test, and evaluation. The focus of initial research and development is on sodium fast reactors, with the eventual goal of the research being developing the necessary sensor technology, quantifying sensor survivability and long-term measurement reliability for nondestructively inspecting critical components. Materials for sensor development that are likely to withstand the harsh environments are described, along with a status on the fabrication of reference specimens, and the planned approach for design and evaluation of the sensor and measurement technology.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Chapter 2: Commercial and Industrial Lighting Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

The Commercial and Industrial Lighting Evaluation Protocol (the protocol) describes methods to account for gross energy savings resulting from the programmatic installation of efficient lighting equipment in large populations of commercial, industrial, and other nonresidential facilities. This protocol does not address savings resulting from changes in codes and standards, or from education and training activities. A separate Uniform Methods Project (UMP) protocol, Chapter 3: Commercial and Industrial Lighting Controls Evaluation Protocol, addresses methods for evaluating savings resulting from lighting control measures such as adding time clocks, tuning energy management system commands, and adding occupancy sensors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Unreviewed Disposal Question Evaluation: Waste Disposal in Engineered Trenches 3 and 4

Revision 0 of this UDQE addressed the proposal to place Engineered Trench #3 (ET#3) in the footprint designated for Slit Trench #12 (ST#12) and operate using ST#12 disposal limits. Similarly, Revision 1 evaluates whether ET#4 can be located in and operated to Slit Trench #13 (ST#13) disposal limits. Both evaluations conclude that the proposed operations result in an acceptably small risk of exceeding a SOF of 1.0 and approve these actions from a performance assessment (PA) perspective. Because ET#3 will be placed in the location previously designated for ST#12, Solid Waste Management (SWM) requested that the Savannah River National Laboratory (SRNL) determine if the ST#12 limits could be employed as surrogate disposal limits for ET#3 operations. SRNL documented in this Unreviewed Disposal Question Evaluation (UDQE) that the use of ST#12 limits as surrogates for the new ET#3 disposal unit will provide reasonable assurance that Department of Energy (DOE) 435.1 performance objectives and measures (USDOE, 1999) will be protected. Therefore, new ET#3 inventory limits as determined by a Special Analysis (SA) are not required.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Underground Test Area Activity Sampling Technologies Evaluation Report, Nevada National Security Site, Nye County, Nevada, Revision 0

This report presents the results of the next stage of sampling technology evaluations as described in Underground Test Area Activity Sampling Technologies Methods Plan (N-I, 2014b). Testing of the BESST Blatypus system was originally planned; however, communications with the vendor indicated it is premature for the UGTA Activity to field test this technology. The system currently uses latex tubing and nitrogen gas to push the water to the surface. The large amount of nitrogen gas needed due to the depths of the UGTA wells makes this unfeasible. Also, the latex tubing will likely not hold up in steel tubing. Instead, three technologies were evaluated: depth-discrete bailer, jack pump, and submersible pump. Each of these is a proven technology for certain conditions. The evaluation includes logistical and operational data collected during the purging of the well or completion interval and groundwater sampling at three wells.

54 ENVIRONMENTAL SCIENCES↗

Criticality Evaluation of Low Density Product Oxides for Air Transport for the ES-3100 Package

This document presents the criticality safety evaluation of the Y-12 National Security Complex (Y-12) Model ES-3100 package for the addition of lower bulk density limits for HEU product oxides transported by air. The current authorized oxide density range for air transport is 2.0 to 6.54 g/cm 3 . The analysis in this report looks at lower densities, specifically in the range of 1.0 to 2.0 g/cm 3 . For reasons presented in this report, it was decided to present the entire range of oxide densities (1.0 to 6.54 g/cm 3 ) as a series of sub-ranges. The lowest density in each range was evaluated. Thus calculations were performed for the following oxide densities: 5.0 g/cm 3 , 4.0 g/cm 3 , 3.0 g/cm 3 , 2.0 g/cm 3 , 1.5 g/cm 3 and 1.0 g/cm 3 . Calculations presented herein were performed using a third generation computing platform; the Microway Parallel Linux Cluster ENGHPC workstation using the Monte Carlo Criticality Safety Analysis Sequence (CSAS5) criticality code sequence and 238-group ENDF/B-VII cross-section library of Standardized Computer Analysis for Licensing Evaluation (SCALE) 6.1.3 (ORNL/TM-2005/39, SCALE: A Comprehensive Modeling and Simulation Suite for Nuclear Safety Analysis and Design).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

On-Road Fuel Cell Electric Vehicles Evaluation: Overview

This report presents an overview of an evaluation of on-road fuel cell electric vehicles (FCEVs) by the National Renewable Energy Laboratory (NREL). The project addressed the need for current, on-road FCEV data and sought to validate improved performance and longer durability from comprehensive sets of early FCEVs, including early market vehicles. This report provides an overview of the evaluation project and partners, describes NREL's evaluation approach, and presents a summary of the results. Detailed results for durability, fuel economy, deployment and driving behavior, and specifications are published in separate reports.

33 ADVANCED PROPULSION SYSTEMS↗

Criticality Safety Evaluations (Part 1) [Slides]

Determine what a criticality safety evaluation is. Define the components to a criticality safety evaluation. Define what is needed and how to create a criticality safety evaluation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A hierarchical evaluation framework for assessing climate simulations relevant to the energy-water-land nexus (Final Report)

The overarching goal was to construct a hierarchy of new and well-tested metrics and analysis tools that support both fundamental and use-inspired research. Motivating this goal was a convergence of needs from climate scientists and stakeholders alike for a systematic, robust framework of model evaluation and diagnosis to provide scientific insights, inform model development, support best practices for the use of climate model outputs, and facilitate communication of climate information in the evolving landscapes of multi-model, multi-resolution, and large ensemble simulations that generate terabytes of data for any single climate run. Steps toward attaining these goals benefited from expertise and established capability of the project team, which included leadership of the North American Regional Climate Change Assessment Program (NARCCAP) and the Coordinated Regional Downscaling Experiment (CORDEX), development of hierarchical model evaluation approaches, and successful research in the analysis and diagnosis of climate model skill, as well as the understanding and modeling of regional climate processes in North America. As part of the overarching goal, the project worked to disseminate a suite of methodologies, algorithms, and software components that the wider community can employ to advance climate science and applications. With rigorous demonstration, the evaluation framework and the mix of standard and high risk / high reward approaches helped form the basis for future development of a computationally enabled user-friendly system for community use.

17 WIND ENERGY↗

FY21 Progress of the Oak Ridge Health Physics Research Reactor CAAS Benchmark Evaluation [Slides]

The FY21 version of the evaluation, focusing on element 57 dose at 3 meters, was presented at the ICSBEP Technical Review Group meeting in October 2021 and was not accepted for 2022 publication in the handbook. The main issue was identified and replacement of the element 57 neutron dose benchmark metric by neutron fluence (closer to what was measured) is required. A subgroup was formed, confident for the updated neutron fluence evaluation to be accepted in the ICSBEP handbook. The updated evaluation will be presented again at the 2022 ICSBEP TRG for publication in the 2023 handbook.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

140,142 Cerium Resolved Resonance Region Evaluation [Slides]

The presentation covers an overview of 140,142 Ce Isotopes, including new evaluations of 140,142 Ce that were requested by the Hanford Plutonium Finishing plant to the Nuclear Criticality Safety Program. It also discusses current ENDF/B-VIII.0 evaluation, which has an error in the 1-2 keV range. It was evaluated using multi-level Breit-Wigner and 142Ce has room for extending resolved resonance region current upper limit from 13 keV. The presentation also discusses new transmission and capture measurements of nat Ce and 142 Ce from Klaus Guber. It also states that no known integral experiments prominently feature Cerium.

07 ISOTOPE AND RADIATION SOURCES↗

Bayesian Monte-Carlo Evaluation Framework of Differential and Integral Data [Slides]

This presentation discusses the Bayesian Monte Carlo evaluation framework of differential and integral data, specifically in relation to two methods that are based on Bayes theorem, which assumes that all PDFs are normal (Gaussian) and that they use a linear approximation for IBEs. The presentation states that basic components of the MC evaluation framework include the computation of random MC ensemble from ENDF File 32, the simulation of IBEs and R-matrix cross section compared to experimental data, and the computation of weighted averages. It also states that the application to U-233 indicates deviation from the conventional linear approximation. In conclusion, evaluation framework will require MCMC method e.g., Metropolis-Hastings (M.-H.).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ORNL neutron cross section measurements and evaluations for improved nuclear data [Slides]

This presentation discusses the nuclear data measurements and evaluation work for NCSP, including its objective which is to provide measured and evaluated thermal, resonance, unresolved resonance, and fast region cross-section data to address the priority NCSP nuclear data needs. It also discusses its vision which addresses multiple Nuclear Data 5- and 10-year goals and attributes identified in the NCSP Vision. The intended final product is that rigorous ENDF/B evaluations will be produced from cross section measurements and analyses. Measurement work effort focused on NCSP priorities by NCSP Nuclear Data Advisory Group (NDAG) can be found in Appendix B of the 5-year plan. NCSP measurements program at JRC is now part of the DOE/Euratom agreement, Action Sheet 66.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗