Search NASA⌕ Search

SEARCH · Search NASA

Results for “Engineering software development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,664 records · Page 93

Data Analytics for Electrical Distribution Systems with Micro PMUs (GMLC 1.4.9 Technical Report)

This report describes how electrical utilities with residential, industrial, commercial and government customers make decisions using Data Analytics (DA) applications and discusses how OpenFMB was leveraged to share that data among disparate types of devices for DA. OpenFMB is a data standard developed by utilities for distributed communication and control of power system assets. Here we explored how OpenFMB can be used for sharing analytics and what those analytics could be for a set of representative grid devices. A review of DA applications performed by electrical utilities and customers is presented. An overview of how the testbed we used was built and configured is summarized. Several experiments which were carried out to explore the capabilities of OpenFMB alongside other data sharing mechanisms for gathering sensor measurements and sharing analytics is also discussed. And finally a comparison of OpenFMB and LBNL’s SPARK framework is summarized. Today’s electrical utilities focus on monitoring the real-time customer consumptions, offering new real-time tariff models based on customer usage habits (rewards and punishments), providing energy peak during peak load times (plan energy generation and distribution), improving the load management for transformers and power lines, and controlling the energy and grid resources efficiently. On the other hand, the DA applications for residential customers are based on modifying the customer electricity usage habit to save money, making accurate and timely decisions for electrical billing. However, the DA applications for industrial, commercial and government customers focus on creating efficient programs to improve the environmental condition (reducing CO₂ emission), developing better load forecasting for industrial and/or commercial activities. In this project, a testbed was built to explore how the OpenFMB framework can be used to distribute data among various types of representative grid edge devices. Micro PMUs (Phasor Measurement Unit) were used to collect and transmit data to an OpenPDC server alongside relays with a framework configured with a system using OpenFMB to collect and transmit data. The testbed was composed of a physical asset based on a 60 Hz AC radial power system constructed using SI-GRID components. The power system consisted of a 3-phase 14 volts line-to-ground (24 volts line-to-line) power source, three 3-phase line emulators, a programmable resistive load bank, two smart relays, two micro PMUs, and a (SCADA) and Phasor Data Concentrator (PDC) computer. This testbed configuration allowed us to perform breaker operation tests collecting data from the micro PMUs and from the relays’ sensors. During the micro PMU breaker operation tests we collected the measured and estimated fundamental voltages, currents, frequency as well as the total true, reactive and apparent power. The displacement power factor from two micro PMUs located in parallel power lines was also used. The software steps for the implementation of the Synchrophasor system are explained in detail in this report. The setting (1-2-3) and data collection (4-5) phases were performed with a free download open source software. In the setting phase, the micro PMUs were set (1), the data stream for each micro PMU was validated, and the connection and configuration files were created (2). The PDC computer was set using the connection and configuration files of the micro PMUs (3). In the data collection phase, the binary data from the micro PMUs was collected (4), and the binary data files of the micro PMUs was converted to analyze the test results (5). OpenFMB was configured to use protocol translators to read Modbus and transform the reading into the OpenFMB data model to be read for DA applications.Our experiments showed that by leveraging the OpenFMB data model and the micro PMUs together we could obtain better situational awareness of network faults, which in some cases could lead to failures in the system and would be less perceivable otherwise. For example, in one experiment the fundamental RMS current angle, and the fundamental displacement power factor (estimated by the ratio between the measured real and apparent total power) had a disturbance at the micro PMU connected to the beginning of the parallel power line because the breaker was opened without the operators or SCADA system’s knowledge, and no current was available. Based on the breaker state scenarios and micro PMU locations, the DA applications using the current angle and displacement power factor from the micro PMUs should be studied in detail to avoid a non-desired measurement that could affect the decision from the DA. Also, the sample rates for PMU, Relay and micro PMU devices were compared. The DA application improved the control and operation between the electrical utilities and their customers (residential, industrial, transportation, commercial and government). The higher the sample rate, the better the quality of the measurement for DA estimations.

42 ENGINEERING↗

Austin Sustainable and Holistic Integration of Energy Storage and Solar PV [Austin SHINES]. Final Report, Version 2

The Austin SHINES project and solution is a software management platform, for an electric grid with a high penetration of dispersed photovoltaic (PV) solar generation sites, which maintains the traditional power quality and reliability associated with grid service. This project developed and deployed the platform as a Distributed Energy Resource Management System (DERMS), engaging multiple advanced controls, to evaluate operation and optimization of a fleet of diverse DER assets, installed at several locations among Austin Energy’s customers and distribution system. The project also produced a methodology to create a replicable DERMS template, adaptable to other regions and market structures. Last, Austin SHINES aimed to demonstrate the solution’s methodology would enable the DER grid ecosystem to serve load at a technical cost (System Levelized Cost of Electricity, or System LCOE) of less than the U.S. Department of Energy SHINES program metric of $0.14/kWh, in a defined boundary, while enabling a high penetration of distributed PV. Research was categorized in 6 reports (Final Deliverables = FD) listed below, with titles and descriptions indicating which area of understanding was investigated: FD-1: System Levelized Cost of Electricity (System LCOE) Methodology The creation and use of the System LCOE to Serve Load metric that encompasses the holistic, system-level costs and benefits of all resources, and enables them to be evaluated based on their ability to support an efficient and low-cost integrated grid ecosystem. FD-2: Software Platform Product Description The creation of new DER control methodologies deployable within a utility-grade software platform that enable DER's to maximize their benefit within a grid, that is capable of serving load enabling a high penetration of distributed PV generation. FD-3: Optimal Design Methodology Optimal design methodologies for individual DER installations that enable utilities to determine the optimal combinations and sizing for individual DER sites. FD-4: Austin SHINES Ownership and Operation Models for DER System Performance A comparison of multiple DER aggregation and ownership methodologies including direct utility control, third-party aggregator, and autonomous. FD-5: Economic Modeling & Optimization A comparison of multiple DER technology mixes and configurations within the distribution system, providing insight into an optimal blend of technologies that best enable the distribution system to serve load at the lowest cost at high penetrations of solar. FD-6: Fielded Assets Deployed DER assets within the Austin Energy SHINES circuits. Austin SHINES provided an opening for state-of-the-art technology products to be deployed, providing a rich opportunity for improving how each of the products perform as stand-alone products, and in concert with other complementary products. The Austin SHINES project comprised of two key metrics for System LCOE: SystemLCOE_SHINES<$0.14/kWh Modeled ΔSystemLCOE_SHINES/ΔSystemLCOE_Base≥20% at same solar penetration The System LCOE calculation uses the costs of the utility-owned infrastructure as it exists today, the cost of the DERs that exist in the system today, and the cost of the purchase of energy from ERCOT wholesale markets over the course of the calendar year. All costs are on an annualized basis. The capital and operating costs are derived from the rate case, which produces a yearly cost. The net cost of energy and services imported to the system is integrated over the test year, as is the load served and solar penetration. The first metric was easily achieved by every scenario considered. The goal was set when the Department of Energy’s SHINES Funding Opportunity Announcement was written in 2015 and was a more difficult target at the time. Due mostly to rapidly declining costs for DERs and the significant decrease in the Electric Reliability Council of Texas (ERCOT) energy market prices, which results in lower net cost of energy purchases, the System LCOE is well below this target for all scenarios considered. A fleet of DERs can assume different mixtures, each of which serves the load at a different LCOE. The optimal mixture of DERs serves load at the smallest System LCOE. The second metric (hereinafter %delta metric) asks that the holistic DERMS controls reduce the incremental cost above the baseline of going to a high solar penetration future by at least 20% as compared to the case of a DER deployment with no sophisticated controls (autonomous). Many comparison sets were created throughout this project. Physical technology was installed for informing utility engineering and testing several types of operational control schemes, through the DERMS. The types of operational control which were compared for valuation of the System LCOE Metric were: Holistic control = using the full suite of the DERMS platform to decide and optimize how/why the systems operate depending on weather, market, and reliability signal input. Autonomous control = a local mode at the asset site, wherein a schedule operates the asset, with visibility into performance only No control = the baseline for comparing value against the other two types of control The types of ownership control included: Direct Utility control = the utility dispatches a signal to each asset Third-Party Aggregator = a third party aggregates a fleet of assets and the utility dispatches one signal for all Autonomous = a local mode is set for operation at the asset site, wherein a schedule operates the asset, with visibility into performance only The types of control methodologies deployable within a utility-grade software platform included: Utility Peak Load Reduction = Lower transmission cost obligation Day-Ahead Energy Arbitrage = Realize economic value through price differential Real-Time Price Dispatch = Realize economic value from real-time price spikes Voltage support = Reduce losses and increase solar generation Distribution Congestion Management = Increase local grid reliability Demand Charge Reduction = Lower customer bills and realize system benefit The fielded assets deployed for the project were: Utility Scale Kingsbery Energy Storage System: 1.5 MW / 3 MWh Li-Ion battery storage Mueller Energy Storage System: 1.75 MW / 3.2 MWh Li-Ion battery storage, 7 Energy Storage Units (250 kW each) La Loma Community Solar: 2.6 MW Commercial Scale Aggregated storage installations at 3 sites, with existing solar (300+ kW): One 18 kW / 36 kWh Li-Ion battery storage Two 72 kW / 144 kWh Li-Ion battery storage Residential Scale Aggregated storage installations: -Six stationary battery storage systems (10 kWh each) at homes with existing solar -One Electric Vehicle installed as Vehicle-to-Grid (V2G) Utility-Controlled Solar via Smart Inverters at 12 homes Autonomously-Controlled Smart Inverters at 6 homes Over the course of the project, Austin SHINES undertook installing more than 3 MW of distributed battery energy storage, smart PV inverters, a DER control platform, and other enabling technologies utilizing customer and utility locations and aggregation models. All of these resources were to be integrated and optimized at the utility level. DER assets and control methodologies were designed to achieve a credible pathway to a System LCOE for energy delivered to load of $0.14//kWh or less by 2020, while maximizing distributed solar generation and maintaining acceptable standards of power quality. The project also established a template for other regions to follow, to maximize the adoption of distributed solar PV in support of an economic and efficient grid. In total, the Austin SHINES project added value to the DER subject area in each layer of integration. From utility, to commercial to residential scales, the sheer hierarchy of communication and coordination was a significant accomplishment in addition to learnings from what these communications revealed was unique to each. Economically, the most effective method demonstrated was the criticality of planning phases. Contingencies and multiple projection scenarios helped guide the project to deploy optimal design as close as feasible, in real world conditions. The project and reports will serve public benefit by outlining specific areas of DER strategy and installation where many stakeholders and needs can be addressed with improved efficiency. Overall, communities and utilities should use the results to guide the increasing options available for powering the grid with DER, renewables, and carbon considerate energy.

14 SOLAR ENERGY↗

Developing And Scaling an OpenFOAM Model to Study Turbulent Flow in a HFIR Coolant Channel

Improving the understanding of how computational fluid dynamics (CFD) direct numerical simulations (DNS) of flows in the High Flux Isotope Reactor (HFIR) perform when run in parallel using the high performance computing (HPC) platform Summit at the Oak Ridge Leadership Computing Facility (OLCF) is of particular importance to boost the computational tools used to support HFIR conversion to low enriched fuel (LEU). Evaluation of scaling performance was driven by the increasing importance of graphics processing unit (GPU) usage in HPC, which is becoming the standard for modern supercomputers such as Summit. The desired results are to obtain a strong positive correlation between the computational resources dedicated to a problem and the relative speed-up of the simulation in comparison to a benchmark. This capability will allow substantially improvement in HFIR flow analytical capabilities, specifically when predicting turbulence properties at high Reynolds numbers. The study leverages previous simulation results performed with code PHASTA (finite element) on HPC platforms Cori (NERSC) and Theta (ALCF) [1] with computing options provided in the computing platform OpenFOAM (finite volume) at OLCF. Transitioning from PHASTA to OpenFOAM will (1) eliminate dependence on third-party software for mesh generation and manipulation, (2) reduce resource needs by employing modern architectures, and (3) build expertise for future modeling of HFIR-specific problems like heat transfer in involute geometry, entrance effects, flow structure in channel corners, and so on—all important issues when defining the available thermal margins in the transition to LEU. CPUs and GPUs differ significantly in their architecture and utilization, as discussed in the literature [2]. The most important differences are in the approach to computations and their memory. A single GPU contains a large quantity of cores, enabling it to perform with a much higher throughput than a CPU, but execution requires a different approach. GPU codes execute instructions using the Single-Instruction Multiple-Thread (SIMT) approach in which a single instruction is used for groups of threads called warps. A warp typically consists of 32 threads which must execute the same set of instructions, although on separate threads. Alternately, a CPU has far fewer cores that are much more flexible in their operation, excelling at quickly performing more complex serial computations. This is why GPUs have greater throughput when properly utilized. The second important difference is seen when comparing their memory spaces. Limited memory allocations and CPU–GPU communications cause a significant bottleneck in GPU-accelerated programs. Further study was required to properly take advantage of GPU resources. A comprehensive analysis of code performance and the model-specific features of turbulence constitutes the core of this work. In this study, a DNS simulation of HFIR channel turbulence was performed with the finite volume CFD code OpenFOAM v2112 and CUDA v11.0 on Red Hat Enterprise Linux v8.2. The OpenFOAM installation had AMGx integrated to enable GPU acceleration and utilizes the PETSc4FOAM library. The computational resources and the problem size were scaled on CPU and CPU + GPU architectures to gain a better understanding of the performance of a DNS problem on modern computing hardware. The study aimed to analyze the scaling of the code exclusively on CPUs and then to examine the scaling of the codes with GPU acceleration enabled. Scaling studies included CPU and GPU acceleration on a mesh of varying resolution to analyze the impact of problem size relative to computational resources. In the course of preparing the GPU configuration on Summit, mainly using the AMGX solvers, difficulties were encountered stemming from constant changes resulting from extensive ongoing development activities and the changing environment. This resulted in the inability to complete the GPU portion of the work. The code was compiled and tested, but production runs to assess acceleration were not performed because the used discretional compute time allocation expired as year-end approached. The Summit HPC platform is scheduled for decommissioning in 2024, making it unattractive for future use with Nvidia-based GPUs. Therefore, the work will be moved onto NERSC machines in FY24. An application was prepared and submitted, and sufficient node-hours were awarded to continue the research in the next calendar year. This report summarizes work performed thus far, which mostly focused on CPU OpenFOAM computing.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

X-Ray Imaging and Spectroscopy Mission

The X-Ray Imaging and Spectroscopy Mission (XRISM) is a joint mission between the Japan Aerospace Exploration Agency (JAXA) and the National Aeronautics and Space Administration (NASA) in collaboration with the European Space Agency (ESA). In addition to the three space agencies, universities and research institutes from Japan, North America, and Europe have joined to contribute to developing satellite and onboard instruments, data-processing software, and the scientific observation program. XRISM is the successor to the ASTRO-H (Hitomi) mission, which ended prematurely in 2016. Its primary science goal is to examine astrophysical problems with precise, high-resolution X-ray spectroscopy. XRISM promises to discover new horizons in X-ray astronomy. It carries a 6 × 6 pixelized X-ray microcalorimeter on the focal plane of an X-ray mirror assembly (Resolve) and a co-aligned X-ray CCD camera (Xtend) that covers the same energy band over a large field of view. XRISM utilizes the Hitomi heritage, but all designs were reviewed. The attitude and orbit control system was improved in hardware and software. The spacecraft was launched from the JAXA Tanegashima Space Center on 2023 September 6 (UTC). During the in-orbit commissioning phase, the onboard components were activated. Although the gate valve protecting the Resolve sensor with a thin beryllium X-ray entrance window was not yet opened, scientific observation started in 2024 February with the planned performance verification observation program. The nominal observation program commenced with the following guest observation program beginning in 2024 September.

Astronomy and AstroPhysics↗

Comparability of Liquid Chromatography Tandem Mass Spectrometry Analysis of Dissolved Organic Matter across Laboratories

Non-targeted liquid chromatography tandem highresolution mass spectrometry (LC−MS/MS) is increasingly applied for the structure-resolved chemical analysis of dissolved organic matter (DOM). With new developments in MS instrumentation and analysis software, the approach has gained substantial momentum over the past decade. However, achieving high-quality analytical data that is reproducible and comparable across laboratories can be a bottleneck in non-targeted metabolomics and organic matter chemical analysis, especially for data reuse in repository-scale analyses. Understanding the capabilities as well as challenges of comparing LC−MS/MS data from different laboratories is necessary for inferring global trends from public data sets. To illuminate instrumentation factors that drive differences and variability, we used a standardized data analysis pipeline, including classical (CMN) and featurebased molecular networking (FBMN), to analyze data from a ring trial by 24 laboratories on identical sample sets of algal and DOM extracts that were mixed in predefined concentrations and spiked with standards. Our results showed that data sets from similar mass spectrometer types with unified instrument parameters were qualitatively comparable, resolving the same general trends and shared mass spectral features. Interlaboratory comparability was best for high-intensity features, while low-intensity features showed greater detection variability. Our analysis also highlights challenges when comparing data from instruments with different acquisition rates or operating with less standardized methods. Lastly, we provide recommendations for data integration, public data sharing, standardization, and best practices for standardized LC−MS/MS data acquisition, which will be critical for long-term time series and intercomparability of DOM chemical analyses.

DOM↗

The Psyche Gamma-Ray and Neutron Spectrometer

A Gamma-Ray and Neutron Spectrometer (GRNS) instrument has been developed as part of the science payload for NASA’s Discovery Program Psyche mission to the M-class asteroid (16) Psyche. The GRNS instrument is designed to measure the elemental composition of Psyche with the goal to understand the origin of this mysterious, potentially metal-rich planetary body. The GRNS will measure the near-surface abundances for the elements Ni, Fe, Si, K, S, Al, and Ca, as well as the spatial distribution of Psyche’s metal-to-silicate fraction (or metal fraction). These measurements address three of the five Psyche mission science objectives: determine if Psyche is a core; determine whether small metal bodies incorporate light elements into the metal phase; and determine whether Psyche was formed under reducing conditions. The Gamma-Ray Spectrometer (GRS) uses a cryocooled, high-purity Ge (HPGe) sensor to detect cosmic-ray generated gamma rays in the 60 to 9000-keV energy range. The HPGe sensor is surrounded by a borated plastic anticoincidence shield that provides three functions: active background rejection from charged particle interactions in the HPGe sensor; fast neutron measurements; and direct measurements of the incident galactic cosmic ray flux. The Neutron Spectrometer (NS) uses three 3 He gas proportional sensors, each with different material wraps to measure thermal (<0.4 eV), low-energy epithermal (0.4 eV to 1 keV), and high-energy epithermal (up to 100 keV) neutrons. This paper provides an overview of the Psyche GRNS, including: its science and measurement objectives; the design of the instrument hardware, software, and operation; pre-launch performance measurements and its initial performance in space; and an overview of its data products and expected operation for different Psyche mission phases.

Engineering - Instrumentation related to nuclear s↗

Commercial Building Technology Demonstration (Final Scientific/Technical Report)

The background for this project was a unique and innovative concept that had been proposed and demonstrated by enVerid Systems, reducing the energy consumption in HVAC systems in commercial and public buildings by up to 50% at peak loads. The concept involves selective scrubbing of gas contaminants from indoor air as a practical substitute for outside air ventilation, the latter being the conventional practice today. This scrubbing enables recycling of most of the indoor air and significantly decreasing the amount of outside air, resulting in a reduced HVAC load and commensurate energy savings for the facility. Key to our approach is low cost scrubbing of all gas contaminants from indoor air using novel, efficient and regenerable sorbent materials. The total solution, labeled HLR (HVAC Load Reduction) is implemented by means of compact modules that can be retrofitted onto virtually any building, and utilizes novel sorbents that have been developed and brought to scale production by enVerid. Although the technology had been deployed and demonstrated, the US commercial building and HVAC markets, famously conservative with respect to innovation and new technologies, had yet to embrace the idea or the product. The overarching goal of the project was to help overcome market hesitancy and enable widespread adoption, by creating a critical mass of success stories across different regions and building types, all under oversight and verification of the DOE and NREL, to ensure credibility and accuracy. The project, overall, was a resounding success. Several installations were deployed and tested comprehensively for the impact on both energy consumption and indoor air quality, and results were not only excellent, but quantitatively in line with expectations. A total number of eight (8) installations were attempted, with 2 aborted due to building issues. Of the six successful installations, however, complete M&V was performed by NREL on 2 (Miami and NYC) and partial analysis on a third site (ArcBest), and these three, along with their results, were therefore presented from a financial and reporting standpoint. Although the number of case studies fell short of the original target of 10, we nevertheless had excellent demonstrations in vastly different climate zones: Southeast, Northeast and Midwest, and in very different building types. This included a modern high-rise office building in New York City and a University Campus health center in Miami, and a mid-rise high-density office in Arkansas. The cooling load reduction was shown to be significant, averaging 37% during the final cooling season in the Miami site. In the NYC site, the cooling energy savings were generally less, at around 12%, as expected. While this is a lower number for average/total savings, two comments are important to note: (i) the outside airflow (OA) reduction was not consistent during the data collection period, at least in part understating the attainable savings through incorrect measurement of the “high energy” reference state; and (ii) the peak impact in NYC is almost certainly as high as Miami, with critical ramifications for peak load reduction and equipment downsizing ability. Importantly, the measured energy savings in all locations were related to the outdoor climate conditions and the actual achievable reduction in outside air, very much in line with models and calculations; this leaves us with increased confidence in our understanding of the interaction between the technology and the building, and our ability to project the impact of this innovation in the future, through broad adoption. Simply put: the energy savings and load reduction impact of the HLR solution has been confirmed quantitatively. The results also confirmed the air quality objective. This may be even more significant, in that air quality is more complex and harder to measure and quantify, and the performance of the HLR as an air scrubber is the linchpin of the entire solution. In all sites, indoor air quality met or exceeded the required parameters, in terms of achieving the target (low) levels of indoor pollutants. Furthermore, the concentrations of outdoor sourced pollutants were markedly lower, as expected, mostly due to the reduction in outside air intake although in part also due to the scrubbing. The success was not immediate nor easy, and early challenges with the systems, especially (but not only) around controls and communication, caused delays in commissioning and undermined some of our M&V schedules. The good news is no fundamental issues were encountered and the number of such glitches was declining quickly by the end of the project. Other challenges had to do with coordinating the control of the building OA dampers, which the HLR needs to have in order to deliver the load reduction, but which the facility manager controls regularly and independently. This is not necessarily a problem for normal HLR operation but interferes with accurate M&V, where switching OA settings back and forth on a precise timetable is essential for clean data. The project provided valuable experience in retrofitting buildings that had been originally designed to operate with less recirculation and more outside air, and some key learnings related to the cyclical regeneration of the sorbents in the operational environment of the building. Some of these learnings gave already been incorporated into ongoing improvements in the design of the HLR module as well as the software that is used to control its operation. The cost and time of retrofit installations is much better understood; so is the test and balance procedure of the building that determines the available range of outside air reduction, which in turn determines the amount of load reduced. We had also implemented at least one annual cycle of sorbent cartridge replacement in the field, after which we tested the used sorbent to assess the rate of degradation of sorbent potency – an important factor affecting the long-term economics of HLR deployments. A notable shortfall of the project, other than the fact that the number of sites was below target, was that we had not (yet) completed testing to measure and verify (M&V) the winter energy savings. This is primarily due to late start on the NYC sites (Miami does not portend any heating savings associated with reduced outside air), combined with the issues of OA damper control. It is by no means suggested that such savings cannot be captured, only that the M&V with respect to winter in NYC has been incomplete. The value of this project and its interest to the general public are hard to overstate. The case studies created from Miami and especially from NYC have, without a doubt, opened up the interest of the broad HVAC industry to HLR in the past year. Major manufacturer reps have signed up to represent and promote the product, and dozens of top tier engineering consultants have introduced HLR as a base of design in upcoming construction and renovation projects – precisely the overarching goal of this project. These would not have happened without the highly visible installation in NYC and its ultimately satisfied customer. Furthermore, the DOE itself issued a report in late 2017 analyzing hundreds of candidate technologies for reducing energy consumption in HVAC; remarkably, the budding HLR solution ranked among the top 3(!); no doubt, its status as a viable and significant contender on this list is informed by the success of these demonstrations. And furthermore, in the wake of these demos, several major energy utilities, led by ConEdison in NYC, have endorsed the HLR solution and now routinely provide substantial cash rebates for customers choosing to incorporate the HLR in their buildings and reap the benefit of the reduced peak load as well as reduced cumulative energy demand. Last but not least, in January of 2019, as this report was being written, the HLR module won the AHR Expo Innovation Award for Green Buildings and, remarkably, the prestigious and only Product of the Year 2019, being selected by an independent professional panel of judges from AHR and ASHRAE. Given the confirmation of the enormous energy saving potential of HLR in widescale deployment, as well as ancillary but significant benefits in terms of equipment downsizing and indoor air quality, the benefit of this effort to the public speaks for itself. Accelerating adoption of HLR, without dependence on subsidies and driven by the private sector, is well under way. There is still much work to be done in terms of educating the HVAC and construction ecosystems and improving the product’s robustness and simplicity, to further facilitate the adoption of this technology and the capture of its potential value. But the American public will greatly benefit both directly and indirectly in the immediate future and beyond.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Subtask 1.1 – Advanced Characterization of Unconventional Oil and Gas Reservoirs to Enhance CO2 Storage Resource Estimates

The Energy & Environmental Research Center (EERC) developed methods and approaches for advanced characterization of unconventional oil and gas reservoirs to enhance CO2 storage resource estimates using samples collected from organic-rich shales of the Bakken Formation. The project was funded under U.S. Department of Energy (DOE) Cooperative Agreement No. DE-FE0024233, with nonfederal cost share provided by Hitachi High Technologies America. The project participants included the EERC, Hitachi High Technologies America, the team at the National Energy Technology Laboratory’s (NETL’s) computed tomography (CT) scanning laboratory in Morgantown, West Virginia, and several NETL staff who have worked on CO2 storage resource estimation. Investigations on the use of subsurface geologic formations for CO2 storage have been ongoing for many years. In the last decade, improvements in directional drilling technology and hydraulic fracturing of organic-rich shale and other tight rock formations have opened new opportunities for CO2 storage, with the potential cobenefit of enhancing gas and oil recovery. Gas-bearing, organic-rich shales have been of particular interest as a carbon storage target because their ability to store large volumes of CO2 is implied by their ability to store methane; however, estimating the CO2 storage resource of organic-rich shales and other unconventional reservoirs is challenging because of the lack of detailed geologic and petrophysical data that are needed to develop improved volumetric equations. According to NETL’s method for estimating regional-scale CO2 storage resources, the key factors that control CO2 storage in geologic formations include void space within induced fractures, natural fractures and matrix pores, as well as the occurrence and distribution of organic matter (OM) and clay minerals. A key goal of this effort was to use field emission scanning electron microscopy (FESEM) analysis of fine-grain unconventional reservoir rocks coupled with advanced image analysis and machine learning techniques to quantify the occurrence and distribution of porosity, OM, and clay minerals. By better understanding the potential migration pathways of CO2 within tight rocks and quantifying the occurrence of sorptive components (OM and clays) along potential flow pathways, methods to estimate the CO2 storage resource of such rocks can be refined. The Bakken petroleum system (Bakken) was used as the source of rock samples for this effort because it includes organic-rich shales with contrasting degrees of thermal maturity as well as tight, nonshale clastic rocks with varying clay mineral content. To better understand the key components of interest in tight rock samples, the EERC worked closely with Hitachi to optimize the FESEM settings necessary to resolve the sample mineralogy, porosity and OM content at micro- to nanoscale resolution. The EERC also worked closely with Hitachi to apply and improve its advanced mineral identification and characterization system (AMICS) software so that it is better suited for mineral identification at the high resolution necessary to resolve features of interest in fine-grained rocks such as organic-rich shales. The EERC also applied advanced image analysis software packages, including Ilastik, to classify and quantify the key components of interest within the samples using FESEM imagery. These advanced techniques allowed for quantification and differentiation of the void space within fractures, pores and OM, as well as a technique to determine and quantify the key mineral and OM components surrounding pore spaces. Being able to better quantify the void space and the potential accessibility of CO2 to sorptive minerals or OM within tight rocks allows for improved estimation of the CO2 storage resource potential of organic-rich shales and other unconventional formations. The information derived from the image analysis techniques was used to refine NETL’s method for estimating regional-scale CO2 storage resources in collaboration with staff from NETL. An additional goal of this work was to better understand rates of CO2 permeation, flow pathways, and sorption in organic-rich shales and nonshale reservoir rocks and to evaluate potential changes in CO2 flow over time. The EERC conducted long-duration (several weeks) CO2 flow-through testing at reservoir conditions using Bakken shale and nonshale samples to assess CO2 permeation rates and retention/sorption within core plugs to represent bulk matrix behavior. Conventional isothermal adsorption testing over a range of pressure conditions was also performed on pulverized Bakken samples to better assess potential maximum sorptive capacity of the samples. The results of this testing illustrated the higher sorptive capacity of the Bakken shales when compared to the sorptive capacity of the nonshale reservoir rock, which contains very little OM when compared to the Bakken shales. The results also illustrate the differences in permeation behavior as a function of fracture flow versus matrix flow. In an attempt to visualize CO2 permeation and flow behavior in Bakken shale samples over time, the EERC collaborated with NETL’s CT Lab in Morgantown, West Virginia. A variety of tests were performed at the NETL lab on unfractured and fractured samples of the Bakken shale. The unfractured Bakken shale samples did not result in CO2 migration within the samples over the testing duration; thus imagery of CO2 migration pathways within the matrix of Bakken samples was not obtained. The results of the flow-through testing within fractured samples illustrate changes in CO2 permeation rates over time, with a trend of decreasing CO2 flow over time. The results of this effort suggest that FESEM analysis coupled with advanced image analysis and machine learning techniques are effective in characterizing and quantifying the mineralogy, porosity, fractures, and OM content of 2-D imagery at the high resolution needed to identify features of interest in tight rocks. In addition, the image analysis techniques allow for identification and quantification of different porosity types as well as the key mineral components and/or OM that CO2 would contact in the reservoir as it migrates through pores and fracture networks. This is key information needed to better estimate the CO2 storage resource potential of organic-rich shales and other tight reservoirs. Additional work is needed to determine the sorptive capacity of the individual sample components (OM and clay minerals) at reservoir conditions so that this approach and the refined CO2 storage resource equation can be applied to other shale and unconventional reservoirs. In addition, subsequent work should be performed to better understand the number of images needed to use stereological approaches to estimate the volume of sample components using 2-D imagery, to explore machine learning techniques to differentiate between induced vs. natural fractures, and to estimate the connectivity of pores and fracture networks using 2-D imagery. Being able to derive this information at the microscale would facilitate scaling up of the sample characterization data used for reservoir modeling and simulation to estimate the CO2 storage resource potential of tight formations.

03 NATURAL GAS↗