A Non-Intrusive Optical Technology to Measure in-situ Heliostat Optical Errors
An innovative non-intrusive optical (NIO) characterization method is presented to measure slope errors and canting errors of heliostats.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
An innovative non-intrusive optical (NIO) characterization method is presented to measure slope errors and canting errors of heliostats.
A procedural error of measuring the temperature on the ceramic material surface in testings carried out on radiative heating installations has been estimated. Different methods of attaching contact temperature sensors are investigated. Using mathematical simulation accounting for the thermophysical properties of all materials, good qualitative and quantitative agreement between calculated and experimental values of temperature has been obtained in the temperature sensor–sample system. Recommendations for reducing the error of measuring the frontal surface of samples in carrying out thermal tests on a radiative heating stand are given.
A postprocessing technique for mixed finite element methods for the Cahn-Hilliard equation is developed and analyzed. Once the mixed finite element approximations have been computed at a fixed time on the coarser mesh, the approximations are postprocessed by solving two decoupled Poisson equations in an enriched finite element space (either on a finer grid or a higher-order space) for which many fast Poisson solvers can be applied. The nonlinear iteration is only applied to a much smaller size problem and the computational cost using Newton and direct solvers is negligible compared with the cost of the linear problem. The analysis presented here shows that this technique remains the optimal rate of convergence for both the concentration and the chemical potential approximations. The corresponding error estimate obtained in our paper, especially the negative norm error estimates, are non-trivial and different with the existing results in the literatures.
The operation of a quantum computer is considered as a general quantum operation on a mixed state on many qubits followed by a measurement. The general quantum operation is further represented as a Feynman–Vernon double path integral over the histories of the qubits and of an environment, and afterward tracing out the environment. The qubit histories are taken to be paths on the two-sphere S{sup 2} as in Klauder’s coherent-state path integral of spin, and the environment is assumed to consist of harmonic oscillators initially in thermal equilibrium, and linearly coupled to to qubit operators Ŝ{sub z}. The environment can then be integrated out to give a Feynman–Vernon influence action coupling the forward and backward histories of the qubits. This representation allows to derive in a simple way estimates that the total error of operation of a quantum computer without error correction scales linearly with the number of qubits and the time of operation. It also allows to discuss Kitaev’s toric code interacting with an environment in the same manner.
Autoencoders have demonstrated remarkable success in learning low-dimensional latent features of high-dimensional data across various applications. Assuming that data are sampled near a low-dimensional manifold, we employ chart autoencoders, which encode data into low-dimensional latent features on a collection of charts, preserving the topology and geometry of the data manifold. Our paper establishes statistical guarantees on the generalization error of chart autoencoders, and we demonstrate their denoising capabilities by considering n noisy training samples, along with their noise-free counterparts, on a d-dimensional manifold. By training autoencoders, we show that chart autoencoders can effectively denoise the input data with normal noise. We prove that, under proper network architectures, chart autoencoders achieve a squared generalization error in the order of n–$\frac{2}{d+2}$log 4 n, which depends on the intrinsic dimension of the manifold and only weakly depends on the ambient dimension and noise level. We further extend our theory on data with noise containing both normal and tangential components, where chart autoencoders still exhibit a denoising effect for the normal component. As a special case, our theory also applies to classical autoencoders, as long as the data manifold has a global parametrization. Furthermore, our results provide a solid theoretical foundation for the effectiveness of autoencoders, which is further validated through several numerical experiments.
The “residual source estimator”, an implicit residual-based spatial discretization error estimator for S N neutron transport methods, is introduced. The estimator uses an approximation of the residual as a fixed source for an analogous transport problem whose solution is the error estimate, using the same transport operator as the original numerical solution. The complete derivation of the residual source estimator, the approximation of the residual, and higher-order derivatives is included. The performance of the residual source estimator for 0-order DGFEM is tested against reference solutions. For problems with true solutions discontinuous in the first derivative across the singular characteristics, the residual source estimator is generally accurate, precise, and computationally affordable compared to similar estimators. It suffers in problems where solutions are discontinuous, particularly when the discontinuity inflicts significant inaccuracies on the discrete solution; however, compared to other estimators, which suffer similarly, it remains a competitive option.
We present a strategy for estimating the error of truncated functional flow equations. While the basic functional renormalization group equation is exact, approximated solutions by means of truncations do not only depend on the choice of the retained information, but also on the precise definition of the truncation. Therefore, results depend on specification parameters that can be used to quantify the error of a given truncation. We demonstrate this for the BCS–BEC crossover in ultracold atoms. Within a simple truncation the precise definition of the frequency dependence of the truncated propagator affects the results, indicating a shortcoming of the choice of a frequency independent cutoff function.
Purpose: To assess residual setup errors during head and neck radiation therapy and the resulting consequences for the delivered dose for various patient alignment procedures. Methods and Materials: Megavoltage cone beam computed tomography (MVCBCT) scans from 11 head and neck patients who underwent intensity modulated radiation therapy were used to assess setup errors. Each MVCBCT scan was registered to its reference planning kVCT, with seven different alignment procedures: automatic alignment and manual registration to 6 separate bony landmarks (sphenoid, left/right maxillary sinuses, mandible, cervical 1 [C1]-C2, and C7-thoracic 1 [T1] vertebrae). Shifts in the different alignments were compared with each other to determine whether there were any statistically significant differences. Then, the dose distribution was recalculated on 3 MVCBCT images per patient for every alignment procedure. The resulting dose-volume histograms for targets and organs at risk (OARs) were compared to those from the planning kVCTs. Results: The registration procedures produced statistically significant global differences in patient alignment and actual dose distribution, calling for a need for standardization of patient positioning. Vertically, the automatic, sphenoid, and maxillary sinuses alignments mainly generated posterior shifts and resulted in mean increases in maximal dose to OARs of >3% of the planned dose. The suggested choice of C1-C2 as a reference landmark appears valid, combining both OAR sparing and target coverage. Assuming this choice, relevant margins to apply around volumes of interest at the time of planning to take into account for the relative mobility of other regions are discussed. Conclusions: Use of different alignment procedures for treating head and neck patients produced variations in patient setup and dose distribution. With concern for standardizing practice, C1-C2 reference alignment with relevant margins around planning volumes seems to be a valid option.
The residual Monte Carlo (RMC) method is also known in the literature as sequential Monte Carlo and reduced-source Monte Carlo. Given a Monte Carlo method for solving a linear equation and an approximate solution to that system, the residual method enables use of essentially the same Monte Carlo algorithm to directly compute the additive error or “defect” associated with the approximate solution. As the size of the defect decreases relative to the size of the solution, the residual Monte Carlo method becomes increasingly efficient relative to the standard Monte Carlo (SMC) method. Here we present a new RMC algorithm for evaluating the space-angle error in S n radiation transport solutions, and provide computational examples demonstrating that it can be far more efficient than SMC for this purpose. Herein we also describe a particular pitfall that must be avoided if RMC is to be efficient, and explain why the performance of RMC can significantly differ between different transport problems and different quantities of interest for the same problem.
The purpose of this study was to evaluate the impact of daily setup error and interfraction organ motion on the overall dosimetric radiation treatment plans. Twelve patients undergoing definitive intensity-modulated radiation therapy (IMRT) treatments for prostate cancer were evaluated in this institutional review board-approved study. Each patient had fiducial markers placed into the prostate gland before treatment planning computed tomography scan. IMRT plans were generated using the Eclipse treatment planning system. Each patient was treated to a dose of 8100 cGy given in 45 fractions. In this study, we retrospectively created a plan for each treatment day that had a shift available. To calculate the dose, the patient would have received under this plan, we mathematically 'negated' the shift by moving the isocenter in the exact opposite direction of the shift. The individualized daily plans were combined to generate an overall plan sum. The dose distributions from these plans were compared with the treatment plans that were used to treat the patients. Three-hundred ninety daily shifts were negated and their corresponding plans evaluated. The mean isocenter shift based on the location of the fiducial markers was 3.3 {+-} 6.5 mm to the right, 1.6 {+-} 5.1 mm posteriorly, and 1.0 {+-} 5.0 mm along the caudal direction. The mean D95 doses for the prostate gland when setup error was corrected and uncorrected were 8228 and 7844 cGy (p < 0.002), respectively, and for the planning target volume (PTV8100) was 8089 and 7303 cGy (p < 0.001), respectively. The mean V95 values when patient setup was corrected and uncorrected were 99.9% and 87.3%, respectively, for the PTV8100 volume (p < 0.0001). At an individual patient level, the difference in the D95 value for the prostate volume could be >1200 cGy and for the PTV8100 could approach almost 2000 cGy when comparing corrected against uncorrected plans. There was no statistically significant difference in the D35 parameter for the surrounding normal tissue except for the dose received by the penile bulb and the right hip. Our dosimetric evaluation suggests significant underdosing with inaccurate target localization and emphasizes the importance of accurate patient setup and target localization. Further studies are needed to evaluate the impact of intrafraction organ motion, rotation, and deformation on doses delivered to target volumes.
Sunshape and reflector surface slope error distributions are significant elements in modelling the optical behaviour of a concentrating solar power system. Different optical modelling tools implement these elements with various approaches. Discrepancies can easily accumulate in simulations of a large optical system as a result of incorrect implementations. This study reviews and verifies the implementations of these two factors in six tools that are widely used for optical modelling in solar energy research: Tonatiuh, SolTrace, Tracer, Solstice, Heliosim and SolarPILOT. The review incorporates three rounds of tests. Firstly, basic tests examine each factor carefully in simplified on-axis reflector-target configurations (round 'A'). Secondly, off-axis effects are introduced (round 'B'). Thirdly, full heliostat field simulations are verified (round 'C'). All of the test cases are simulated with each modelling tool, and results are compared. Discrepancies were observed due to approximations inherent in the cone optics (convolution) methods, incorrect implementation the of pillbox slope errors, different approaches to setting the circumsolar ratio for the Buie sunshape, and different approaches to the calculation of blocking and shading losses in some tools. All issues are discussed fully, and solutions to most issues were implemented within the scope of the present study. Some remaining issues are noted. The study highlights the importance of careful implementation of these aspects of optical modelling and contributes to an improvement in the quality of several widely-used tools.
We know that native point defects play an important role in carrier transport properties of CH3NH3PbI3. However, the nature of many important defects remains controversial due partly to the conflicting results reported by recent density functional theory (DFT) calculations. In this Letter, we show that self-interaction error and the neglect of spin–orbit coupling (SOC) in many previous DFT calculations resulted in incorrect positions of valence and conduction band edges, although their difference, which is the band gap, is in good agreement with the experimental value. Moreover, this problem has led to incorrect predictions of defect-level positions. Hybrid density functional calculations, which partially correct the self-interaction error and include the SOC, show that, among native point defects (including vacancies, interstitials, and antisites), only the iodine vacancy and its complexes induce deep electron and hole trapping levels inside of the band gap, acting as nonradiative recombination centers.
New x-ray imaging crystal spectrometers, currently operating on Alcator C-Mod, NSTX, EAST, and KSTAR, record spectral lines of highly charged ions, such as Ar{sup 16+}, from multiple sightlines to obtain profiles of ion temperature and of toroidal plasma rotation velocity from Doppler measurements. In the present work, we describe a new data analysis routine, which accounts for the specific geometry of the sightlines of a curved-crystal spectrometer and includes corrections for the Johann error to facilitate the tomographic inversion. Such corrections are important to distinguish velocity induced Doppler shifts from instrumental line shifts caused by the Johann error. The importance of this correction is demonstrated using data from Alcator C-Mod.
We developed and implemented an algorithm to determine and correct systematic distortions in low-energy electron diffraction (LEED) images. The procedure is in principle independent of the design of the apparatus (spherical or planar phosphorescent screen vs. channeltron detector) and is therefore applicable to all device variants, known as conventional LEED, micro-channel plate LEED, and spot profile analysis LEED. The essential prerequisite is a calibration image of a sample with a well-known structure and a suitably high number of diffraction spots, e.g., a Si(111)-7×7 reconstructed surface. The algorithm provides a formalism which can be used to rectify all further measurements generated with the same device. In detail, one needs to distinguish between radial and asymmetric distortion. Additionally, it is necessary to know the primary energy of the electrons precisely to derive accurate lattice constants. Often, there will be a deviation between the true kinetic energy and the value set in the LEED control. Here, we introduce a method to determine this energy error more accurately than in previous studies. Following the correction of the systematic errors, a relative accuracy of better than 1% can be achieved for the determination of the lattice parameters of unknown samples.
The development of a volumetric apparatus (also known as a Sieverts’ apparatus) for accurate and reliable hydrogen adsorption measurement is shown. The instrument minimizes the sources of systematic errors which are mainly due to inner volume calibration, stability and uniformity of the temperatures, precise evaluation of the skeletal volume of the measured samples, and thermodynamical properties of the gas species. A series of hardware and software solutions were designed and introduced in the apparatus, which we will indicate as f-PcT, in order to deal with these aspects. The results are represented in terms of an accurate evaluation of the equilibrium and dynamical characteristics of the molecular hydrogen adsorption on two well-known porous media. The contribution of each experimental solution to the error propagation of the adsorbed moles is assessed. The developed volumetric apparatus for gas storage capacity measurements allows an accurate evaluation over a 4 order-of-magnitude pressure range (from 1 kPa to 8 MPa) and in temperatures ranging between 77 K and 470 K. The acquired results are in good agreement with the values reported in the literature.
We elucidate the origin of large differences (two-fold or more) in the fixed-node errors between the first- vs second-row systems for single-configuration trial wave functions in quantum Monte Carlo calculations. This significant difference in the valence fixed-node biases is studied across a set of atoms, molecules, and also Si, C solid crystals. We show that the key features which affect the fixed-node errors are the differences in electron density and the degree of node nonlinearity. The findings reveal how the accuracy of the quantum Monte Carlo varies across a variety of systems, provide new perspectives on the origins of the fixed-node biases in calculations of molecular and condensed systems, and carry implications for pseudopotential constructions for heavy elements.
Optimal error field correction (EFC) is thought to be achieved when coupling to the least-stable “dominant” mode of the plasma is nulled at each toroidal mode number (n). The limit of this picture is tested in the DIII-D tokamak by applying superpositions of in- and ex-vessel coil set n = 1 fields calculated to be fully orthogonal to the n = 1 dominant mode. In co-rotating H-mode and low-density Ohmic scenarios, the plasma is found to be, respectively, 7× and 20× less sensitive to the orthogonal field as compared to the in-vessel coil set field. For the scenarios investigated, any geometry of EFC coil can thus recover a strong majority of the detrimental effect introduced by the n = 1 error field. Despite low sensitivity to the orthogonal field, its optimization in H-mode is shown to be consistent with minimizing the neoclassical toroidal viscosity torque and not the higher-order n = 1 mode coupling.
This work is motivated by a quite general question: Under which circumstances are the capacities of information transmission systems continuous? The research is explicitly carried out on finite arbitrarily varying quantum channels (AVQCs). We give an explicit example that answers the recent question whether the transmission of messages over AVQCs can benefit from assistance by distribution of randomness between the legitimate sender and receiver in the affirmative. The specific class of channels introduced in that example is then extended to show that the unassisted capacity does have discontinuity points, while it is known that the randomness-assisted capacity is always continuous in the channel. We characterize the discontinuity points and prove that the unassisted capacity is always continuous around its positivity points. After having established shared randomness as an important resource, we quantify the interplay between the distribution of finite amounts of randomness between the legitimate sender and receiver, the (nonzero) probability of a decoding error with respect to the average error criterion and the number of messages that can be sent over a finite number of channel uses. We relate our results to the entanglement transmission capacities of finite AVQCs, where the role of shared randomness is not yet well understood, and give a new sufficient criterion for the entanglement transmission capacity with randomness assistance to vanish.