Search NASA⌕ Search

SEARCH · Search NASA

Results for “FASTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Fast microtomography using bright monochromatic x-rays

A fast microtomography system for high-resolution high-speed imaging has been developed using bright monochromatic x-rays at the BL29XU beamline of SPring-8. The shortest scan time for microtomography we attained was 0.25 s in 1.25 {mu}m effective pixel size by combining the bright monochromatic x-rays, a fast rotating sample stage, and a high performance x-ray imaging detector. The feasibility of the tomography system was successfully demonstrated by visualization of rising bubbles in a viscous liquid, an interesting issue in multiphase flow physics. This system also provides a high spatial (a measurable feature size of 300 nm) or a very high temporal (9.8 {mu}s) resolution in radiographs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Collisional and collective effects in two dimensional model for fast-electron transport in refluxing regime

The relativistic laser-driven electron transport in partially or fully ionized matter has been investigated in many recent experiments. The high laser intensity achievable today (up to 10{sup 20} W/cm{sup 2}) allows to generate electron current density above 10{sup 11} A/cm{sup 2}. In this regime, electromagnetic effects start to be dominant over collisional ones. In this context, we have developed a simple 2D model for the fast electron transport accounting for (1) electric effects on the electron penetration range and (2) the electron refluxing in thin foils. We compare our model with those existing in literature and with some recent experimental results on fast electron transport in matter. The model predicts a maximum value for the electron penetration range in the region where the collisional and the resistive effects are comparable.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Note: Measurements of fast electrons in the TORE-SUPRA tokamak by means of modified Cherenkov-type diamond detector

The Note reports on experimental studies of ripple born fast electrons within the TORE-SUPRA facility, which were performed by means of a modified measuring head equipped with diamond detectors designed especially for recording the electron-induced Cherenkov radiation. There are presented signals produced by fast electrons in the TORE-SUPRA machine, which were recorded during two experimental campaigns performed in 2010. Shapes of these electron-induced signals are considerably different from those observed during the first measurements carried out by the prototype Cherenkov probe in 2008. An explanation of the observed differences is given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reduction of the fast electron angular dispersion by means of varying-resistivity structured targets

We present novel structured targets capable of collimating laser-generated fast electrons through dense plasmas. The proposed targets are made of narrow high- and low-Z filaments leading to a transversely modulated electrical resistivity profile. When featuring a spatially decreasing density, these targets permit both to guide the fast electrons and reduce their angular dispersion. The principle of our target design is explained by a theoretical model. Two-dimensional particle-in-cell simulations are performed to demonstrate its efficiency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Studies of the fast ion energy spectra in TJ-II

The dynamics of the neutral beam injection fast ions in the TJ-II stellarator is studied in this paper from both the theoretical and experimental points of view. The code Integrator of Stochastic Differential Equations for Plasmas (ISDEP) is used to estimate the fast ion distribution function in 3D:1D in real space and 2D in velocity space, considering the 3D structure of TJ-II, the electrostatic potential, non turbulent collisional transport, and charge exchange losses. The results of ISDEP are compared with the experimental data from the compact neutral particle analyzer, which measures the outgoing neutral flux spectra in the energy range E Element-Of (1-45) keV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of energetic-particle-driven core magnetic fluctuations and induced fast-ion transport

Internal fluctuations arising from energetic-particle-driven instabilities, including both density and radial magnetic field, are measured in a reversed-field-pinch plasma. The fluctuations peak near the core where fast ions reside and shift outward along the major radius as the instability transits from the n = 5 to n = 4 mode. During this transition, strong nonlinear three-wave interaction among multiple modes accompanied by enhanced fast-ion transport is observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The challenge in making models of fast CMEs

It has been a challenge to explain theoretically how fast CMEs (exceeding {approx} 1,000km/s) occur. Our numerical models suggest that it is not easy to release enough magnetic energy impulsively from an active region. We have been studying CME models that are constrained by observed magnetic fields, with realistic coronal plasma density and temperature profiles, as derived from thermodynamic models of the corona. We find that to get fast CMEs, the important parameters are the magnetic energy density, the magnetic field drop-off index, and the Alfven speed profile in active regions. We describe how we energize active regions, and how we subsequently initiate CMEs via flux cancellation. We contrast CMEs from idealized zero-beta models with more sophisticated models based on thermodynamic solutions.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of a fast radiation detector based on barium fluoride scintillation crystal

Barium fluoride (BaF{sub 2}) is an inorganic scintillation material used for the detection of X/gamma radiation due to its relatively high density, equivalent atomic number, radiation hardness, and high luminescence. BaF{sub 2} has a potential capacity to be used in gamma ray timing experiments due to the prompt decay emission components. It is known that the light output from BaF{sub 2} has three decay components: two prompt of those at approximately 195 nm and 220 nm with a decay constant around 600-800 ps and a more intense, slow component at approximately 310 nm with a decay constant around 630 ns which hinders fast timing experiments. We report here the development of a fast radiation detector based on a BaF{sub 2} scintillation crystal employing a special optical filter device, a multiple reflection multi-path ultraviolet region short-wavelength pass light guides (MRMP-short pass filter) by using selective reflection technique, for which the intensity of the slow component is reduced to less than 1%. The methods used for this study provide a novel way to design radiation detector by utilizing scintillation crystal with several emission bands.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-destructive thermal wave method applied to study thermal properties of fast setting time endodontic cement

The thermal wave method is applied for thermal properties measurement in fast endodontic cement (CER). This new formula is developed upon using Portland cement in gel and it was successfully tested in mice with good biocompatibility and stimulated mineralization. Recently, thermal expansion and setting time were measured, conferring to this material twice faster hardening than the well known Angelus Mineral trioxide aggregate (MTA) the feature of fast hardening (∼7 min) and with similar thermal expansion (∼12 μstrain/ °C). Therefore, it is important the knowledge of thermal properties like thermal diffusivity, conductivity, effusivity in order to match thermally the tissue environment upon its application in filling cavities of teeth. Photothermal radiometry technique based on Xe illumination was applied in CER disks 600 μm thick for heating, with prepared in four particle sizes (25, 38, 45, and 53) μm, which were added microemulsion gel with variation volumes (140, 150, 160, and 170) μl. The behavior of the thermal diffusivity CER disks shows linear decay for increase emulsion volume, and in contrast, thermal diffusivity increases with particles sizes. Aiming to compare to MTA, thermal properties of CER were averaged to get the figure of merit for thermal diffusivity as (44.2 ± 3.6) × 10{sup −3} cm{sup 2}/s, for thermal conductivity (228 ± 32) mW/cm K, the thermal effusivity (1.09 ± 0.06) W s{sup 0.5}/cm{sup 2} K and volume heat capacity (5.2 ± 0.7) J/cm{sup 3} K, which are in excellent agreement with results of a disk prepared from commercial MTA-Angelus (grain size < 10 μm using 57 μl of distilled water)

36 MATERIALS SCIENCE↗

Fast electron transfer from PbSe quantum dots to TiO{sub 2}

Fast electron transfer from PbSe quantum dots (QDs) to the porous anatase TiO{sub 2} film was observed in transient absorption, when the lowest unoccupied molecular orbital level of PbSe QDs is higher than that of TiO{sub 2}. In PbSe QDs 2.7nm in diameter linked to the TiO{sub 2} film the bleaching recovery decay shortened to 1ps from 650ps observed in the non-linked PbSe QDs. The electron transfer from the quantum state in small PbSe QDs to TiO{sub 2} takes place fast and efficiently.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Time-resolved observation of fast domain-walls driven by vertical spin currents in short tracks

We present time-resolved measurements of the displacement of magnetic domain-walls (DWs) driven by vertical spin-polarized currents in track-shaped magnetic tunnel junctions. In these structures, we observe very high DW velocities (600 m/s) at current densities below 10{sup 7} A/cm{sup 2}. We show that the efficient spin-transfer torque combined with a short propagation distance allows avoiding the Walker breakdown process and achieving deterministic, reversible, and fast (≈1 ns) DW-mediated switching of magnetic tunnel junction elements, which is of great interest for the implementation of fast DW-based spintronic devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Polycrystalline CVD diamond detector: Fast response and high sensitivity with large area

Polycrystalline diamond was successfully used to fabricate a large area (diameter up to 46 mm) radiation detector. It was proven that the developed detector shows a fast pulsed response time and a high sensitivity, therefore its rise time is lower than 5 ns, which is two times faster than that of a Si-PIN detector of the same size. And because of the large sensitive area, this detector shows good dominance in fast pulsed and low density radiation detection.

36 MATERIALS SCIENCE↗

Fast wave heating in the NSTX-Upgrade device

NSTX-Upgrade will operate with toroidal magnetic fields (B{sub T}) up to 1 T, nearly twice the value used in the experiments on NSTX, and the available NBI power will be doubled. The doubling of B{sub T} while retaining the 30 MHz RF source frequency has moved the heating regime from the high harmonic fast wave (HHFW) regime used in NSTX to the mid harmonic fast wave (MHFW) regime. By making use of the full wave code AORSA, this work shows that direct ion damping (mainly by thermal ions localized at the 5th harmonic resonance) might be significant in NSTX-Upgrade under TRANSP predicted full performance conditions and the electron and ion absorption is sensitive to the ratio of electron and ion temperature. Launching at high toroidal wave number appears to be one way to significantly reduce the ion damping. By using the extended AORSA code, which includes a detailed description of the scrape-off layer in the field solutions, we found a large electric field amplitude outside of the last closed flux surface as previously seen in NSTX from AORSA simulations (D. L. Green, et al, Phys. Rev. Lett. 107, 145001 (2011)). Preliminary results by introducing a collision damping in the scrape-off layer in the AORSA code to represent a damping process are presented, showing for the first time absorbed power in the scrape-off layer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Note: A fast pneumatic sample-shuttle with attenuated shocks

We describe a home-built pneumatic shuttle suitable for the fast displacement of samples in the vicinity of a highly sensitive atomic magnetometer. The samples are magnetized at 1 T using a Halbach assembly of magnets. The device enables the remote detection of free-induction-decay in ultra-low-field and zero-field nuclear magnetic resonance (NMR) experiments, in relaxometric measurements and in other applications involving the displacement of magnetized samples within time intervals as short as a few tens of milliseconds. Other possible applications of fast sample shuttling exist in radiological studies, where samples have to be irradiated and then analyzed in a cold environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved measurement of photon emission during fast crack propagation in three-point bending fracture of silica glass and soda lime glass

Simultaneous time-resolved measurements of photon emission (PE) and fast crack propagation upon bending fracture were conducted in silica glass and soda lime glass. Observation of fracture surfaces revealed that macroscopic crack propagation behavior was similar between the silica glass and soda lime glass when fracture loads for these specimens were comparable and cracks propagated without branching. However, a large difference in the PE characteristics was found between the two glasses. In silica glass, PE (645–655 nm) was observed during the entire crack propagation process, whereas intense PE (430–490 nm and 500–600 nm) was observed during the initial stages of propagation. In contrast, only weak PE was detected in soda lime glass. These results show that there is a large difference in the atomic processes involved in fast crack propagation between these glasses, and that PE can be used to study brittle fracture on the atomic scale.

36 MATERIALS SCIENCE↗

Investigation of abnormal negative threshold voltage shift under positive bias stress in input/output n-channel metal-oxide-semiconductor field-effect transistors with TiN/HfO{sub 2} structure using fast I-V measurement

This letter investigates abnormal negative threshold voltage shifts under positive bias stress in input/output (I/O) TiN/HfO{sub 2} n-channel metal-oxide-semiconductor field-effect transistors using fast I-V measurement. This phenomenon is attributed to a reversible charge/discharge effect in pre-existing bulk traps. Moreover, in standard performance devices, threshold-voltage (V{sub t}) shifts positively during fast I-V double sweep measurement. However, in I/O devices, V{sub t} shifts negatively since electrons escape from bulk traps to metal gate rather than channel electrons injecting to bulk traps. Consequently, decreasing pre-existing bulk traps in I/O devices, which can be achieved by adopting Hf{sub x}Zr{sub 1−x}O{sub 2} as gate oxide, can reduce the charge/discharge effect.

36 MATERIALS SCIENCE↗

Fast discharge in a spherical cavity

The work is devoted to the study of the plasma, created by a fast discharge in a spherical cavity. The discharge was driven by an inductive storage with plasma erosion opening switch (dI/dt ∼10{sup 12} A/s). The plasma was produced in a spherical cavity (alumina, 11 mm diameter). Xe, Ar, and He at the pressure 80 Pa were used as working gases. The time evolution of the spatial structure and of extreme ultraviolet (EUV) spectra of the discharge plasma was studied by means of micro channel plate detector. The discharges with Xe and Ar resulted in the stable appearance of the spherically shaped plasma with the diameter about 1–3 mm. The plasma emission in the EUV region lasts ∼500 ns. The EUV spectrum of Ar discharge at the moment of maximum of the electron temperature T{sub e} contains the lines of Ar X (ionization potential 478.7 eV), that indicates a value of T{sub e} in the range 50–100 eV. The mechanism of plasma appearance can be the cumulation of the convergent spherical shock wave, generated by fast heat deposition and magnetic pressure in working media near the inner surface of the discharge volume.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mode conversion and absorption of fast waves at high ion cyclotron harmonics in inhomogeneous magnetic fields

The propagation and absorption of high harmonic fast waves is of interest for non-inductive current drives in fusion experiments. The fast wave can be coupled with the ion Bernstein wave that propagates in the high magnetic field side of an ion cyclotron harmonic resonance layer. This coupling and the absorption are analyzed using the hot plasma dispersion relation and a wave equation that was converted from an approximate dispersion relation for the case where λ{sub i}=k{sub ⊥}{sup 2}ρ{sub i}{sup 2}/2≳1 (where k{sub ⊥} is the perpendicular wave number and ρ{sub i} is the ion Larmor radius). It is found that both reflection and conversion may occur near the harmonic resonance layer but that they decrease rapidly, giving rise to a sharp increase in the absorption as the parallel wave number increases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗