Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Voltage Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

A Tri-Port Current-Source Soft-Switching Medium-Voltage String Inverter for Large-Scale Solar-Plus-Storage Farms

This article presents a tri-port current-source soft-switching medium-voltage string inverter (TMVSI) to reduce the Levelized cost of energy (LCOE) of large-scale solar-plus-storage (SPS) farms. Throughout this work, the topology, operating principle, circuit simulation, control, and hardware design of the TMVSI are introduced. In addition, three key challenges compromising the performance of the TMVSI are addressed in this article. First, a new feed-forward compensation for model predictive control of the TMVSI is proposed to compensate for sampling and computational delay and high dc-link ripple with low computational cost and high scalability. Second, the use of laminated permanent magnets is proposed to reduce the losses of the MV medium-frequency transformer (MFT) in the TMVSI while increasing its saturation current. Finally, an improved U-shape winding pattern is proposed to decrease the leakage inductance of the MV MFT and reduce the voltage stress across semiconductor switches without adding cost or complexity. Here, the effectiveness of the TMVSI is validated by experiments at up to 20kW/500V in different test cases with custom-built prototypes. The contributions of this work make the TMVSI a viable solution to SPS farms and unleash its potential for LCOE reduction.

14 SOLAR ENERGY↗

Final Report 200 MW L-Band Annular Beam Klystron for Accelerators

This program developed a 200 MW, 1.3 GHz, Annular Beam Klystron (ABK) for accelerator systems. An ABK provides lower impedance than a conventional klystron, making it possible to produce higher RF powers with lower voltages. With a higher power per unit, fewer klystrons would be required for a large accelerator. Lower voltage also simplifies and reduces the cost of the power supply system. Both features will significantly lower the cost of an RF system. This device operates at 475 kV. The klystron uses a magnetron injection gun producing 1100 A in one microsecond pulses. Power is extracted into fundamental rectangular waveguide through two output windows. The predicted gain is approximately 45 dB with estimated efficiency of 45%. The klystron was assembled, but no facility was available for testing. Consequently, no high power performance measurements are available. Because the assembled klystron is approximately 15 feet long, it was disassembled for storage. It can be reassembled should a use materialize.

43 PARTICLE ACCELERATORS↗

Sol-Gel Based Polybenzimidazole Membranes for Hydrogen Pumping Devices

Electrochemical hydrogen pumping using a high temperature (>100°C) PBI membrane was demonstrated under non-humidified and humidified conditions at ambient pressures. Relatively low voltages were required to operate the pump over a wide range of hydrogen flow rates. The advantages of the high temperature capability were shown by operating the pump on reformate feed gas mixtures containing various amounts of CO and CO 2 . Gas purity measurements on the cathode gas product were conducted and significant reductions in gas impurities were detected. The applicability of the PBI membrane for electrochemical hydrogen pumping and its durability under typical operating conditions was established with tests that lasted for nearly 4000 hours.

08 HYDROGEN↗

Tests and Techniques for Characterizing and Modeling X-43A Electromechanical Actuators

A series of tests were conducted on the electromechanical actuators of the X-43A research vehicle in preparation for the Mach 7 and 10 hypersonic flights. The tests were required to help validate the actuator models in the simulation and acquire a better understanding of the installed system characteristics. Static and dynamic threshold, multichannel crosstalk, command-to-surface timing, free play, voltage regeneration, calibration, frequency response, compliance, hysteretic damping, and aircraft-in-the-loop tests were performed as part of this effort. This report describes the objectives, configurations, and methods for those tests, as well as the techniques used for developing second-order actuator models from the test results. When the first flight attempt failed because of actuator problems with the launch vehicle, further analysis and model enhancements were performed as part of the return-to-flight activities. High-fidelity models are described, along with the modifications that were required to match measurements taken from the research vehicle. Problems involving the implementation of these models into the X-43A simulation are also discussed. This report emphasizes lessons learned from the actuator testing, simulation modeling, and integration efforts for the X-43A hypersonic research vehicle.

Lin, Yohan↗

Operational Parameters, Considerations, and Design Decisions for Resource-Constrained Ion Trap Mass Spectrometers

Mass spectrometers are increasingly finding applications in new and unique areas, often in situations where key operational resources (i.e. power, weight and size) are limited. One such example is the Mars Organic Molecule Analyzer (MOMA). This instrument is a joint venture between NASA and the European Space Agency (ESA) to develop an ion trap mass spectrometer for chemical analysis on Mars. The constraints on such an instrument are significant as are the performance requirements. While the ideal operating parameters for an ion trap are generally well characterized, methods to maintain analytical performance with limited power and system weight need to be investigated and tested. Methods Experiments have been performed on two custom ion trap mass spectrometers developed as prototypes for the MOMA instrument. This hardware consists of quadrupole ion trap electrodes that are 70% the size of common commercial instrumentation. The trapping RF voltage is created with a custom tank circuit that can be tuned over a range of RF frequencies and is driven using laboratory supplies and amplifiers. The entire instrument is controlled with custom Lab VIEW software that allows a high degree of flexibility in the definition of the scan function defining the ion trap experiment. Ions are typically generated via an internal electron ionization source, however, a laser desorption source is also in development for analysis of larger intact molecules. Preliminary Data The main goals in this work have been to reduce the power required to generate the radio frequency trapping field used in an ion trap mass spectrometer. Generally minimizing the power will also reduce the volume and mass of the electronics to support the instrument. In order to achieve optimum performance, commercial instruments typically utilize RF frequencies in the 1 MHz range. Without much concern for power usage, they simply generate the voltage required to access the mass range of interest. In order to reduce the required RF voltage (and power), operation of the ion trap at lower RF frequencies has been investigated. Surprisingly, the performance of the instrument has only been slightly degraded at RF frequencies all the way down to 500 kHz. Mass resolution is relatively stable to this point and depending on the resonant ejection point used, the peak intensity is also quite stable. To date only masses up to m/z 200 have been fully investigated, however, additional studies are planned to verify the performance with higher mass ions. The lower frequency and voltage should reduce the pseudo potential well depth, eventually affecting the trapping efficiency of the instrument -- effect that could manifest itself in significantly limiting the mass range of trapped ions. Other methods to reduce the RF power while maintaining analytical performance are also under investigation. This includes ion ejection at lower q(sub z) values to access a given mass with a lower RF voltage. The loss of mass resolution at lower q(sub eject) points has been measured and current work is underway to leverage scan speed and the use of non-linear resonances in order to counter this trend. The overall trap performance under this range of operating conditions will be presented with a goal of identifying what trade-offs are acceptable.

Danell, Ryan M.↗

Wear Trends of the HERMeS Thruster as a Function of Throttle Point

A series of short-duration (200 hour) wear tests were conducted with two Hall Effect Rocket with Magnetic Shielding (HERMeS) technology demonstration units (TDU). Front pole covers, cathode keeper, and discharge channel wear were characterized as a function of discharge voltage, magnetic field strength, and chamber pressure. No discharge channel erosion was observed. Inner pole cover erosion was shown to be a weak function of discharge voltage with most erosion occurring at the lowest value, 300 volts. The TDU-3 keeper electrode eroded with each operating condition, with high magnetic field yielding the greatest erosion rate. The TDU-1 keeper electrode exhibited net deposition suggesting its configuration is more consistent with meeting overall HERMeS service life requirements. Ratios of molybdenum to graphite erosion rates suggests, with high uncertainty, that the sputtering ions are originating downstream of the thruster exit plane, striking the surface with small angles of incidence.

life (durability)↗

Microfabrication of air core power inductors with metal-encapsulated polymer vias

This paper reports three-dimensional (3-D) microfabricated toroidal inductors intended for power electronics applications. A key fabrication advance is the exploitation of thick metal encapsulation of polymer pillars to form a vertical via interconnections. The radial conductors of the toroidal inductor are formed by conventional plating-through-mold techniques, while the vertical windings (up to 650 mu m in height) are formed by polymer cores with metal plated on their external surfaces. This encapsulated polymer approach not only significantly reduces the required plating time but also exploits the relative ease of fabricating high-aspect-ratio SU-8 pillars. To form the top radial conductors, non-photopatternable SU-8 is introduced as a thick sacrificial layer. Two toroidal inductor geometries were fabricated and tested. The first inductor had an inner diameter of 2 mm, an outer diameter of 6 mm, 25 turns and a vertical via height of 650 mu m. The second inductor had an inner diameter of 4 mm, an outer diameter of 8 mm, 50 turns and a vertical via height of 650 mu m. Both inductor geometries were successfully fabricated and characterized in the frequency range of 0.1-100 MHz. Characterization results of the 25- and 50-turn inductors showed an average inductance of 76 and 200 nH, a low frequency (0.1 MHz) resistance of 0.2 and 1 Omega and a quality factor of 35 and 24 at 100 MHz, respectively. Finite-element simulations of the inductors were performed and agreed with the measured results to within 8%. The turn-to-turn breakdown voltage was measured to be in excess of 800 V and currents as high as 0.5 A could be successfully carried by the inductor windings.

Kim, J↗

Propulsion System Testing for the Iodine Satellite (iSAT) Demonstration Mission

CUBESATS are relatively new spacecraft platforms that are typically deployed from a launch vehicle as a secondary payload, providing low-cost access to space for a wide range of end-users. These satellites are comprised of building blocks having dimensions of 10x10x10 cm cu and a mass of 1.33 kg (a 1-U size). While providing low-cost access to space, a major operational limitation is the lack of a propulsion system that can fit within a CubeSat and is capable of executing high delta v maneuvers. This makes it difficult to use CubeSats on missions requiring certain types of maneuvers (i.e. formation flying, spacecraft rendezvous). Recently, work has been performed investigating the use of iodine as a propellant for Hall-effect thrusters (HETs) 2 that could subsequently be used to provide a high specific impulse path to CubeSat propulsion. 3, 4 Iodine stores as a dense solid at very low pressures, making it acceptable as a propellant on a secondary payload. It has exceptionally high ρIsp (density times specific impulse), making it an enabling technology for small satellite near-term applications and providing the potential for systems-level advantages over mid-term high power electric propulsion options. Iodine flow can also be thermally regulated, subliming at relatively low temperature (less than 100 C) to yield I2 vapor at or below 50 torr. At low power, the measured performance of an iodine-fed HET is very similar to that of a state-of-the-art xenon-fed thruster. Just as importantly, the current-voltage discharge characteristics of low power iodine-fed and xenon-fed thrusters are remarkably similar, potentially reducing development and qualifications costs by making it possible to use an already-qualified xenon-HET PPU in an iodine-fed system. Finally, a cold surface can be installed in a vacuum test chamber on which expended iodine propellant can deposit. In addition, the temperature doesn't have to be extremely cold to maintain a low vapor pressure in the vacuum chamber (it is under 10(exp -6) torr at −75 C), making it possible to 'cryopump' the propellant with lower-cost recirculating refrigerant-based systems as opposed to using liquid nitrogen or low temperature gaseous helium cryopanels. An iodine-based system is not without its challenges. The primary challenge is that the entire feed system must be maintained at an elevated temperature to prevent the iodine from depositing (transitioning from the gas phase directly back into the solid phase), which will block the propellant feed lines. Furthermore, deposition will occur unless the temperature in the lines is not greater than the temperature of the propellant reservoir. The flow rate can be controlled by adjusting the heating applied to the reservoir, but as with any thermal control there is a relatively slow response to changes in the heating rate. In the present paper, we describe the propulsion and propellant feed system for the iodine satellite (iSAT) flight demonstration mission. The system is based around the Busek BHT-200 Hall thruster, which has been modified for chemical compatibility with iodine vapor. While the gross propellant flow rate is maintained by the heated propellant reservoir, the flow to the anode and cathode are adjusted using two heated Vacco proportional flow control valves (PFCV), which provide very fast response on the flow rate adjustment. The flight mission design layout will be presented, showing how the system will be packaged into the overall 12-U spacecraft and the techniques being employed to protect the remaining spacecraft hardware from the propulsion system (e.g., plasma impingement, iodine deposition, thermal loads). In addition to the flight system design, results of testing the thruster and cathode with both operating on iodine propellant are presented. The tests are conducted on a thrust stand (see Fig. 1) in a large vacuum chamber containing a beam dump chilled to below -100 C to 'cryopump' the propellant. The thruster performance during these tests is presented, with these data used to evaluate the feed system and guide further refinements. Results of relatively long duration testing are presented to demonstrate the capability to operate for the length of the iSAT mission and to perform a number of re-starts as will be required by the mission concept of operations.

Polzin, Kurt A.↗

Electric Drive Technologies Consortium (EDTC)/ Cost competitive, high-Performance, highly Reliable (CPR) Power Devices on 4H-SiC (Final Report)

4H-Silicon carbide (4H-SiC) is a wide bandgap semiconductor that offers superior material properties over silicon, including higher critical electric field, thermal conductivity, and electron saturation velocity. These advantages make 4H-SiC highly attractive for high-voltage, high-efficiency power electronics. However, realizing the full potential of SiC requires device technologies that are not only high-performing but also manufacturable and reliable under real-world operating conditions. This report summarizes the outcomes of a five-year R&D effort funded by the U.S. Department of Energy (DOE) under the Electric Drive Technologies Consortium (EDTC), focused on developing cost-competitive, high-performance, and highly reliable (CPR) power devices on 4H-SiC substrates. The program targeted scalable and manufacturable 1.2 kV-class SiC MOSFETs optimized for next-generation electric vehicles, renewable energy systems, and industrial power conversion. The project delivered transformative advancements in SiC power device performance and ruggedness. Particularly, Specific on-resistance (R on,sp ) was reduced by up to 37%, from ~4.0 m$\Omega \cdot$cm 2 in earlier designs to an industry-leading 2.40 m$\Omega \cdot$cm 2 , driven by optimized doping, refined JFET widths, and layout engineering. Breakdown voltages (BV) exceeded 1600 V, marking improvement over legacy baselines, and demonstrating the robustness of newly implemented junction profiles and edge terminations. Short-circuit withstand time (SCWT) saw a remarkable 4$\times$ increase, from ~2 $\mu$s to over 8 $\mu$s, achieved through the successful deployment of deep P-well structures (~1.8–2.0 $\mu$m) via channeling implantation. This innovative process breakthrough enabled precise junction formation without MeV-class implantation tools, reduced leakage under high field stress, and allowed even the shortest-channel devices (down to 0.3 $\mu$m) to achieve both high BV and excellent ruggedness—breaking the traditional trade-off between conduction efficiency and blocking capability. Several novel architectures pushed the performance envelope further. JBSFETs—featuring embedded Schottky portions—eliminated bipolar degradation and drastically reduced third-quadrant leakage, while Ladder MOSFETs introduced a clever orthogonal conduction path that achieved a 15.4% reduction in R on,sp over standard linear designs. Switching performance reached new benchmarks: short-channel devices showed a 31% reduction in total switching energy compared to 0.5 $\mu$m counterparts, while maintaining manageable gate drive requirements. Layout-optimized structures not only improved transconductance but also accelerated switching transitions, pointing to real-world benefits in converter-level efficiency. The devices also passed rigorous reliability validation. Stress-tested across TDDB, HTGB, HTRB, HVP, and burn-in, the devices screened under 30 V/10 hr and 43 V/1 s protocols consistently exhibited tighter lifetime distributions and long-term oxide robustness. These screening techniques proved effective in identifying latent defects and ensuring deployment-grade reliability. Meanwhile, advanced 3D TCAD simulations revealed and resolved electric field hotspots—particularly in HEXFET corners—where fields exceeding 4.8 MV/cm were mitigated through geometry-aware layout corrections. Overall, the results of this project demonstrate a manufacturable and scalable SiC power device platform that addresses key DOE performance targets for efficient, robust, and reliable 1.2kV 4H-SiC Power Devices. The developed technologies represent a meaningful step forward in the commercial readiness of high-voltage SiC solutions and provide a strong foundation for continued advancement in wide bandgap power electronics.

42 ENGINEERING↗

Hydrogen Production System Scaling Using a High-Fidelity Simulation-Optimization Framework

Proton exchange membrane (PEM) electrolyzers are widely used for hydrogen production, yet few validated, high-fidelity tools can reliably guide scale-up. Using measured performance from a 50-hour hardware-in-the-loop pilot test, a physics-based, plant-level model of a 1.25 MW PEM electrolyzer and its balance-of-plant (BoP) subsystems is developed and validated. The model couples electrochemistry and thermal/flow submodels and is calibrated against pilot test data via a genetic algorithm (GA) workflow. Validation yields a mean absolute percentage error (APE) of 0.43% for cell voltage and stack power. Two scale-out strategies are then benchmarked under a common 7-day wind-and-photovoltaic (PV) profile: (i) linear duplication of 1.25 MW blocks and (ii) shared-BoP architectures. Sharing BoP between stacks reduces BoP energy by 27% at 10 MW and 34% at 100 MW (vs. linear duplication) and improves system specific energy consumption (SEC) to 52.9 and 52.6 kWh/kg, respectively (from 54.0 kWh/kg with linear duplication). Partial-load studies (25-100% set-point) show that cumulative hydrogen production remains nearly constant down to 50% load because all cases use the same weekly renewable-energy input. Below 50%, the power cap limits how much energy can be used within 168 h, which reduces hydrogen output. The model further indicates that the practical operating optimum lies between 50% and 85% load, where efficiency gains begin to appear without significant loss in hydrogen output. Moreover, the efficiency gains at lower loads are offset by reduced production. The validated framework supports scenario-based engineering trade-off studies for large configurations (10-100 MW) and for operating policies under variable renewables.

08 HYDROGEN↗

Development of a low-inductance SiC trench MOSFET power module for high-frequency application

This paper deals with the development of a low-inductance multiple-chip power module with state-of-art 1200 V SiC Trench MOSFETs for high-frequency application. Specifically, a phase-leg power module package with integrated decoupling capacitance is fabricated based on P-cell/N-cell concept, and the packaging design is discussed in detail. Dedicated double pulse test is built, and a gate driver with cross-talk suppression function is designed to support the fast switching speed operation of SiC Trench MOSFETs. The parasitic inductance and current density distribution of the power module are simulated and extracted for the purpose of voltage spike limiting. The temperature dependent static and switching characteristics of the developed module are evaluated as well, and the key differences from traditional SiC double-diffused MOS (DMOS) are identified and discussed. Based on the turn-off switching characterization results, a lumped equivalent power-loop parasitic inductance of ~6 nH is achieved for the designed power module.

Wang, Zhiqiang↗

Power processor for a 20CM ion thruster

A power processor breadboard for the JPL 20CM Ion Engine was designed, fabricated, and tested to determine compliance with the electrical specification. The power processor breadboard used the silicon-controlled rectifier (SCR) series resonant inverter as the basic power stage to process all the power to the ion engine. The breadboard power processor was integrated with the JPL 20CM ion engine and complete testing was performed. The integration tests were performed without any silicon-controlled rectifier failure. This demonstrated the ruggedness of the series resonant inverter in protecting the switching elements during arcing in the ion engine. A method of fault clearing the ion engine and returning back to normal operation without elaborate sequencing and timing control logic was evolved. In this method, the main vaporizer was turned off and the discharge current limit was reduced when an overload existed on the screen/accelerator supply. After the high voltage returned to normal, both the main vaporizer and the discharge were returned to normal.

Biess, J. J.↗

A linearly controlled direct-current power source for high-current inductive loads in a magnetic suspension wind tunnel

The NASA Langley 6 inch magnetic suspension and balance system (MSBS) requires an independently controlled bidirectional DC power source for each of six positioning electromagnets. These electromagnets provide five-degree-of-freedom control over a suspended aerodynamic test model. Existing power equipment, which employs resistance coupled thyratron controlled rectifiers as well as AC to DC motor generator converters, is obsolete, inefficient, and unreliable. A replacement six phase bidirectional controlled bridge rectifier is proposed, which employs power MOSFET switches sequenced by hybrid analog/digital circuits. Full load efficiency is 80 percent compared to 25 percent for the resistance coupled thyratron system. Current feedback provides high control linearity, adjustable current limiting, and current overload protection. A quenching circuit suppresses inductive voltage impulses. It is shown that 20 kHz interference from positioning magnet power into MSBS electromagnetic model position sensors results predominantly from capacitively coupled electric fields. Hence, proper shielding and grounding techniques are necessary. Inductively coupled magnetic interference is negligible.

Tripp, John S.↗

Carbon Corrosion in CO2 Electrolysis Systems

Driven by concerns over climate change, interest in CO2 conversion technologies has dramatically increased in recent years. By viewing CO2 as a readily available feedstock, many pathways for the production of carbon-neutral fuels and chemicals become available. In converting CO2, low carbon emitting energy sources must be used to ensure a low carbon footprint of the fuel and chemical products. The low-temperature electrochemical conversion of CO2 is a promising technology and allows for direct integration with renewable electricity sources. The development of low-temperature CO2 electrolysis technologies is informed by both PEM fuel cells and water electrolyzers, both of which are at a higher stage of development. However, CO2 electrolysis operates at a much higher cell voltage (-3V) than other low-temperature electrochemical processes, which can have implications for materials compatibility in the electrolyzer device. Carbon corrosion is of particular concern for the anode of CO2 electrolyzers, as a large driving force for corrosion exists due to the high required cell potentials. In this presentation, recent observations will be shared on carbon corrosion of the anode gas diffusion electrode (GDE) in low-temperature alkaline exchange membrane CO2 electrolysis. Results from ex-situ tests designed to isolate the carbon corrosion process for anode GDEs will be shared. These results will provide guidance on materials selection for CO2 utilization MEAs, which need to have a lifetime of several years to ensure industrial viability.

BIOMASS FUELS↗

A Compact Linac for Proton Therapy Based on a Dielectric Wall Accelerator

A novel compact CT-guided intensity modulated proton radiotherapy (IMPT) system is described. The system is being designed to deliver fast IMPT so that larger target volumes and motion management can be accomplished. The system will be ideal for large and complex target volumes in young patients. The basis of the design is the dielectric wall accelerator (DWA) system being developed at the Lawrence Livermore National Laboratory (LLNL). The DWA uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. High electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The system will produce individual pulses that can be varied in intensity, energy and spot width. The IMPT planning system will optimize delivery characteristics. The system will be capable of being sited in a conventional linac vault and provide intensity modulated rotational therapy. Feasibility tests of an optimization system for selecting the position, energy, intensity and spot size for a collection of spots comprising the treatment are underway. A prototype is being designed and concept designs of the envelope and environmental needs of the unit are beginning. The status of the developmental new technologies that make the compact system possible will be reviewed. These include, high gradient vacuum insulators, solid dielectric materials, SiC photoconductive switches and compact proton sources.

43 PARTICLE ACCELERATORS↗

Idaho National Laboratory Experimental Research In High Temperature Electrolysis For Hydrogen And Syngas Production

The Idaho National Laboratory (Idaho Falls, Idaho, USA), in collaboration with Ceramatec, Inc. (Salt Lake City, Utah, USA), is actively researching the application of solid oxide fuel cell technology as electrolyzers for large scale hydrogen and syngas production. This technology relies upon electricity and high temperature heat to chemically reduce a steam or steam / CO2 feedstock. Single button cell tests, multi-cell stack, as well as multi-stack testing has been conducted. Stack testing used 10 x 10 cm cells (8 x 8 cm active area) supplied by Ceramatec and ranged from 10 cell short stacks to 240 cell modules. Tests were conducted either in a bench-scale test apparatus or in a newly developed 5 kW Integrated Laboratory Scale (ILS) test facility. Gas composition, operating voltage, and operating temperature were varied during testing. The tests were heavily instrumented, and outlet gas compositions were monitored with a gas chromatograph. The ILS facility is currently being expanded to ~15 kW testing capacity (H2 production rate based upon lower heating value).

08 HYDROGEN↗

SPUTTERED THIN FILMS FOR VERY HIGH POWER, EFFICIENT, AND LOW-COST COMMERCIAL SOFCS

The aim of this project was to leverage the low area specific resistance (ASR) of Redox’s GDC electrolyte-based cell architecture and increase solid oxide fuel cell (SOFC) efficiency (i.e., open circuit voltage, or OCV) without significantly increasing cell resistance. The key to achieving the increased SOFC efficiency is the introduction of a thin sputtered yttria stabilized zirconia (YSZ) electron-blocking layer and a thin sputtered gadolinia doped ceria (GDC) barrier layer on top of the half-cell substrate (i.e., anode and GDC electrolyte). A key initial effort of the project was to improve the quality of the half-cell substrate surface so that any remaining defects were significantly smaller than the desired film thickness. During lab-scale trials, we had to overcome challenges with film cracking during post-sputtering treatments (e.g., thermal anneals) as well as damage to the sputtering targets. After the initial lab-scale trials, the focus shifted toward the use of commercial scale sputtering equipment with a sputtering equipment manufacturer in the microelectronics industry. Using the commercial sputtering equipment, we deposited films with different variations of power, PO2, sputtering time, platen speed, etc. We then determined the combinations of sputtering conditions and post-sputtering treatments that yielded high-quality films without cracks or other significant defects. While thin films were deposited on cells as large as 10 cm by 10 cm, the processing was optimized using 4 cm by 4 cm cells. Cell performance was evaluated in stainless-steel test fixtures between 500 °C and 700 °C with hydrogen fuel fed to the anode and air fed to the cathode. Extensive studies allowed us to determine that modified cathode and cathode contact firing processes were required to achieve theoretical OCV. Moreover, use of the new firing processes resulted in the need for a modified cathode contact to achieve a low ASR. In summary, the project demonstrated the performance of high OCV (1.13 V at 650 °C) from sputtered layers and a low ASR (~0.25 Ohms-cm2 at 650 °C) resulting from a modification of cathode/contact processing and the introduction of alternative contact layers that are sufficient to yield a Gen-1 cell with a maximum power density of approximately 1.2 W/cm2. At an operating voltage of 0.74 V, this would yield a cell power density of ~1.1 W/cm2. While not utilized in this project, a Redox Gen-2 cell has a catalyst-infiltrated porous anode that reduces the ASR by more than 50% from that of the Gen-1 cells used in this project. Therefore, if the sputtered YSZ electron-blocking layer and GDC barrier layer are added to a Gen-2 half cell with a similar increase in OCV to the theoretical value of ~1.13 V at 650 °C, and if the same improvement in ASR (from that demonstrated in this project) is achieved when using the Gen-2 half-cell architecture as a sputtered cell substrate, then the power density at 0.74 Vop could be as high as ~2.6 W/cm2. The impact of such power density gains, while still maintaining high cell efficiency, and thus high system efficiency, is a dramatic decrease in system cost because the stack represents ~30-40% of the SOFC system cost.

01 COAL, LIGNITE, AND PEAT↗

Next-generation anion exchange membrane water electrolyzers operating for commercially relevant lifetimes

Alkaline anion exchange membrane (AEM) water electrolysis has gained increasing attention due to its potential to achieve low-cost, high performance hydrogen production. However, most existing membranes are not durable in industrial settings. In this work, we demonstrate good performance relative to industrial parameters using Sustainion® anion exchange membranes. Long-duration tests showed stable performance of 1 A/cm 2 at 1.85 V with a degradation rate of less than 1 μV/h over 10,000 h. The projected lifetime is thus over 20 years. Daily on/off cycling performance over the course of 30 years was simulated experimentally through accelerated voltage shock tests, resulting in a performance loss of only 0.15 μV/cycle over 11,000 cycles. As shown through impact and crossover testing, an improvement in performance is achieved by the addition of zirconia to the polymer matrix and mechanically reinforcing the membrane.

08 HYDROGEN↗