Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Evaluation of a Bioabsorbable Self-Expandable Vein Stent-Base Made of Poly(l-lactide) In Vitro and In Vivo

PurposeThis study was designed to evaluate performance and tissue response to a self-expandable bioabsorbable vein stent-base cut from a tube with enhanced stiffness and strength in vitro and in vivo.MethodsA diamond-shaped stent-base was cut from a sequential biaxially strained poly(l-lactide) (PLLA) tube for optimized performance. The performance of the stent-base was evaluated in a finite element analysis model, and validation was attempted in vitro through a cyclic flat-plate compression and radial force measurement. The performance of the stent-base was tested in vivo using 3 sheep with 2 implants each for 2 and 3½ weeks, respectively.ResultsIn vitro the stent-base showed an elliptical deformation but no fractures. In vivo the stent-base showed adequate radial force and no migration. All implanted stent-bases showed multiple fractures not only at the predicted stress zones but at all connecting points. Fragments of the caudal stent-base stayed in the vein wall indicating sufficient tissue coverage to avoid embolization of the fractured stent pieces, whereas fragments from the cranial device remaining were few. Neointima formation was confirmed histologically at 2 and 3½ weeks.ConclusionA bioabsorbable self-expandable stent-base made from PLLA for large veins seems feasible, but over time, the PLLA used in this study appears too stiff and lacks the sufficient flexibility to move with the vena cava, causing multiple fractures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulation of Endovascular Aortic Repair Using 3D Printed Abdominal Aortic Aneurysm Model and Fluid Pump

Background: Abdominal aortic aneurysm (AAA) models can be manufactured with 3D printing technology. This study describes detailed methodology and validation of endovascular aortic repair (EVAR) simulation using 3D printed AAA model connected to hemodynamic pump. Method: The AAA model was printed with Objet500 Connex3 (Stratasys, Eden Prairie, MN) and connected to BDC PD-0500 fluid pump (BDC Laboratories, Wheat Ridge, CO). EVAR procedure metrics were benchmarked in two expert implanters and compared to 20 vascular surgical trainees with different levels of EVAR experience (< 20 or ≥ 20 cases). All simulations were performed using commercially available stent grafts, guidewires, catheters, fluoroscopic guidance and digital subtraction angiography. Studied outcomes included ability to complete the procedure independently, time to deploy aortic component, ability to cannulate contralateral gate and complete the repair, and total fluoroscopy and procedure times. Results: A total of 22 EVAR simulation procedures were performed with mean procedure time of 37 ± 12 min. Experienced trainees had significantly lower total procedural time (32 ± 9 vs. 44 ± 6 min, P = 0.003) and fluoroscopic time (13 ± 5 vs. 23 ± 8 min, P = 0.005). All experienced trainees completed the procedure independently in < 45 min, compared to six (46%) of those with less EVAR experience (P = 0.016). Among less experienced trainees, only two (15%) completed the entire procedure independently (P < 0.001). Benchmark implanters performed significantly better than both trainee groups in nearly all EVAR metrics. Conclusion: EVAR simulation was feasible and simulated all procedural steps with high fidelity. This model may be applicable for assessment of technical competencies and standard endovascular skill acquisition within vascular surgery training curricula.

3D PRINTING↗

Simulation Analysis and Performance Study of CoCrMo Porous Structure Manufactured by Selective Laser Melting

To fabricate porous implants with improved biocompatibility and mechanical properties that are matched to their application using selective laser melting (SLM), flow within the mold and compressive properties and performance of the porous structures must be comprehensively studied. Parametric modeling was used to build 3D models of octahedron and hexahedron structures. Finite element analysis was used to evaluate the mold flow and compressive properties of the parametric porous structures. A DiMetal-100 SLM molding apparatus was used to manufacture the porous structures and the results evaluated by light microscopy. The results showed that parametric modeling can produce robust models. Square structures caused higher blood cell adhesion than cylindrical structures. “Vortex” flow in square structures resulted in chaotic distribution of blood elements, whereas they were mostly distributed around the connecting parts in the cylindrical structures. No significant difference in elastic moduli or compressive strength was observed in square and cylindrical porous structures of identical characteristics. Hexahedron, square and cylindrical porous structures had the same stress–strain properties. For octahedron porous structures, cylindrical structures had higher stress–strain properties. Using these modeling and molding results, an important basis for designing and the direct manufacture of fixed biological implants is provided.

36 MATERIALS SCIENCE↗

Engineering micropatterned surfaces to modulate the function of vascular stem cells

Highlights: • We examine vascular stem cell function on microgrooved and micropost patterned polymer substrates. • 10 μm microgrooved surfaces significantly lower VSC proliferation but do not modulate calcified matrix deposition. • Micropost surfaces significantly lower VSC proliferation and decrease calcified matrix deposition. - Abstract: Multipotent vascular stem cells have been implicated in vascular disease and in tissue remodeling post therapeutic intervention. Hyper-proliferation and calcified extracellular matrix deposition of VSC cause blood vessel narrowing and plaque hardening thereby increasing the risk of myocardial infarct. In this study, to optimize the surface design of vascular implants, we determined whether micropatterned polymer surfaces can modulate VSC differentiation and calcified matrix deposition. Undifferentiated rat VSC were cultured on microgrooved surfaces of varied groove widths, and on micropost surfaces. 10 μm microgrooved surfaces elongated VSC and decreased cell proliferation. However, microgrooved surfaces did not attenuate calcified extracellular matrix deposition by VSC cultured in osteogenic media conditions. In contrast, VSC cultured on micropost surfaces assumed a dendritic morphology, were significantly less proliferative, and deposited minimal calcified extracellular matrix. These results have significant implications for optimizing the design of cardiovascular implant surfaces.

60 APPLIED LIFE SCIENCES↗

Development of xeno-free epithelial differentiation media for adherent, non-expanded adipose stromal vascular cell cultures

Reconstruction of respiratory epithelium is critical for the fabrication of bioengineered airway implants. Epithelial differentiation is typically achieved using bovine pituitary extract (BPE). Due to the xenogenic nature and undefined composition of BPE, an alternative for human clinical applications, devoid of BPE, must be developed. The goal of this study was to develop two different BPE-free media, with and without select pituitary hormone (PH), which could initiate epithelial differentiation for use in human implantation.

60 APPLIED LIFE SCIENCES↗

'Mind the Gap'-The Impact of Variations in the Duration of the Treatment Gap and Overall Treatment Time in the First UK Anal Cancer Trial (ACT I)

Purpose: The United Kingdom Coordinating Committee on Cancer Research anal cancer trial demonstrated the benefit of combined modality treatment (CMT) using radiotherapy (RT), infusional 5-fluorouracil, and mitomycin C over RT alone. The present study retrospectively examines the impact of the recommended 6-week treatment gap and local RT boost on long-term outcome. Methods and Materials: A total of 577 patients were randomly assigned RT alone or CMT. After a 6-week gap responders received a boost using either additional external beam radiotherapy (EBRT) (15 Gy) or iridium-192 implant (25 Gy). The effect of boost, the gap between initial treatment (RT alone or CMT) and boost (Tgap), and overall treatment time (OTT) were examined for their impact on outcome. Results: Among the 490 good responders, 436 (89%) patients received a boost after initial treatment. For boosted patients, the risk of anal cancer death decreased by 38% (hazard ratio [HR]: 0.62, 99% CI 0.35-1.12; p = 0.04), but there was no evidence this was mediated via a reduction in locoregional failure (LRF) (HR: 0.90, 99% CI 0.48-1.68; p = 0.66). The difference in Tgap was only 1.4 days longer for EBRT boost, compared with implant (p = 0.51). OTT was longer by 6.1 days for EBRT (p = 0.006). Tgap and OTT were not associated with LRF. Radionecrosis was reported in 8% of boosted, compared with 0% in unboosted patients (p = 0.03). Conclusions: These results question the benefit of a radiotherapy boost after a 6-week gap. The higher doses of a boost may contribute more to an increased risk of late morbidity, rather than local control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Dose-Rate Brachytherapy as a Monotherapy for Favorable-Risk Prostate Cancer: A Phase II Trial

Purpose: There are multiple treatment options for favorable-risk prostate cancer. High-dose-rate (HDR) brachytherapy as a monotherapy is appealing, but its use is still investigational. A Phase II trial was undertaken to explore the value of such treatment in low-to-intermediate risk prostate cancer. Methods and Materials: This was a single-institution, prospective study. Eligible patients had low-risk prostate cancer features but also Gleason scores of 7 (51% of patients) and stage T2b to T2c cancer. Treatment with HDR brachytherapy with a single implant was administered over 2 days. One of four fractionation schedules was used in a dose escalation study design: 3 fractions of 10, 10.5, 11, or 11.5 Gy. Patients were assessed with the Common Terminology Criteria for Adverse Events version 2.0 for urinary toxicity, the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer scoring schema for rectal toxicity, and the Expanded Prostate Cancer Index Composite (EPIC) questionnaire to measure patient-reported health-related quality of life. Biochemical failure was defined as a prostate-specific antigen (PSA) nadir plus 2 ng/ml. Results: Between 2003 and 2008, 79 patients were enrolled. With a median follow-up of 39.5 months, biochemical relapse occurred in 7 patients. Three- and 5-year actuarial biochemical control rates were 88.4% (95% confidence interval [CI], 78.0-96.2%) and 85.1% (95% CI, 72.5-94.5%), respectively. Acute grade 3 urinary toxicity was seen in only 1 patient. There was no instance of acute grade 3 rectal toxicity. Rates of late grade 3 rectal toxicity, dysuria, hematuria, urinary retention, and urinary incontinence were 0%, 10.3%, 1.3%, 9.0%, and 0%, respectively. No grade 4 or greater toxicity was recorded. Among the four (urinary, bowel, sexual, and hormonal) domains assessed with the EPIC questionnaire, only the sexual domain did not recover with time. Conclusions: HDR brachytherapy as a monotherapy for favorable-risk prostate cancer, administered using a single implant over 2 days, is feasible and has acceptable acute and late toxicities. Further follow-up is still required to better evaluate the efficacy of such treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Dose-Rate Brachytherapy as Monotherapy Delivered in Two Fractions Within One Day for Favorable/Intermediate-Risk Prostate Cancer: Preliminary Toxicity Data

Purpose: To report the toxicity profile of high-dose-rate (HDR)-brachytherapy (BT) as monotherapy in a Human Investigation Committee-approved study consisting of a single implant and two fractions (12 Gy Multiplication-Sign 2) for a total dose of 24 Gy, delivered within 1 day. The dose was subsequently increased to 27 Gy (13.5 Gy Multiplication-Sign 2) delivered in 1 day. We report the acute and early chronic genitourinary and gastrointestinal toxicity. Methods and Materials: A total of 173 patients were treated between December 2005 and July 2010. However, only the first 100 were part of the IRB-approved study and out of these, only 94 had a minimal follow-up of 6 months, representing the study population for this preliminary report. All patients had clinical Stage T2b or less (American Joint Committee on Cancer, 5th edition), Gleason score 6-7 (3+4), and prostate-specific antigen level of {<=}12 ng/mL. Ultrasound-guided HDR-BT with real-time dosimetry was used. The prescription dose was 24 Gy for the first 50 patients and 27 Gy thereafter. The dosimetric goals and constraints were the same for the two dose groups. Toxicity was scored using the National Cancer Institute Common Terminology Criteria for Adverse Events, version 3. The highest toxicity scores encountered at any point during follow-up are reported. Results: The median follow-up was 17 months (range, 6-40.5). Most patients had Grade 0-1 acute toxicity. The Grade 2 acute genitourinary toxicity was mainly frequency/urgency (13%), dysuria (5%), hematuria, and dribbling/hesitancy (2%). None of the patients required a Foley catheter at any time; however, 8% of the patients experienced transient Grade 1 diarrhea. No other acute gastrointestinal toxicities were found. The most common chronic toxicity was Grade 2 urinary frequency/urgency in 16% of patients followed by dysuria in 4% of patients; 2 patients had Grade 2 rectal bleeding and 1 had Grade 4, requiring laser treatment. Conclusions: Favorable-risk prostate cancer patients treated with a single implant HDR-BT to 24-27 Gy in two fractions within 1 day have excellent tolerance with minimal acute and chronic toxicity. Longer follow-up is needed to confirm these encouraging early results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Implementation of High-Dose-Rate Brachytherapy and Androgen Deprivation in Patients With Prostate Cancer

Purpose: To evaluate outcome (overall survival [OS], the actuarial 5-year cancer-specific survival [CSS], disease-free survival [DFS], biochemical failure-free survival [BFS]), complications and morbidity in patients treated with high-dose-rate brachytherapy (HDR-BT) boost and hormonal treatment with curative aims. Methods: Between 2004 and 2009, 275 prospectively followed pN0/N0M0 patients were included: 19 patients (7%) with T2, Gleason score 7 and prostate-specific antigen (PSA) <10 and 256 patients (93%) with T3 or Gleason score 8-10 or PSA >20 received multimodal treatment with conformal four-field radiotherapy (prostate/vesiculae 2 Gy Multiplication-Sign 25) combined with HDR-BT (iridium 192; prostate 10 Gy Multiplication-Sign 2) with long-term androgen deprivation therapy (ADT). Results: After a median observation time of 44.2 months (range, 10.4-90.5 months) 12 patients had relapsed clinically and/or biochemically and 10 patients were dead, of which 2 patients died from prostate cancer. Five-year estimates of BFS, CSS, DFS, and OS rates were 98.5%, 99.3%, 95.6%, and 96.3%, respectively. None of the patients with either Gleason score <8 or with intermediate risk profile had relapsed. The number of HDR-BT treatments was not related to outcome. Despite of age (median, 65.7 years; range, 45.7-77 years) and considerable pretreatment comorbidity in 39 of 275 patients, Genitourinary treatment-related morbidity was moderate with long-lasting Radiation Therapy Oncology Group Grade 2 voiding problems in 26 patients (9.5%) and occasionally mucous discharge in 20 patients (7%), none with Grade >2 for gastrointestinal at follow-up. Complications during implantations were related to pubic arch interference (4 patients) and lithotomy time, causing 2 patients to develop compartment syndrome. Conclusion: Despite still preliminary observations, our 5-year outcome estimates favor the implementation of high-dose-rate brachytherapy in high-risk patients combined with conformal external radiotherapy and long-term ADT. High-quality implants can be achieved by a trained specialized team at a high-turnover center using transrectal ultrasound-based treatment plans with acceptable morbidity and complication rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sexual Function and the Use of Medical Devices or Drugs to Optimize Potency After Prostate Brachytherapy

Purpose: Prospective evaluation of sexual outcomes after prostate brachytherapy with iodine-125 seeds as monotherapy at a tertiary cancer care center. Methods and Materials: Subjects were 129 men with prostate cancer with I-125 seed implants (prescribed dose, 145 Gy) without supplemental hormonal or external beam radiation therapy. Sexual function, potency, and bother were prospectively assessed at baseline and at 1, 4, 8, and 12 months using validated quality-of-life self-assessment surveys. Postimplant dosimetry values, including dose to 10% of the penile bulb (D10), D20, D33, D50, D75, D90, and penile volume receiving 100% of the prescribed dose (V100) were calculated. Results: At baseline, 56% of patients recorded having optimal erections; at 1 year, 62% of patients with baseline erectile function maintained optimal potency, 58% of whom with medically prescribed sexual aids or drugs. Variables associated with pretreatment-to-posttreatment decline in potency were time after implant (p = 0.04) and age (p = 0.01). Decline in urinary function may have been related to decline in potency. At 1 year, 69% of potent patients younger than 70 years maintained optimal potency, whereas 31% of patients older than 70 maintained optimal potency (p = 0.02). Diabetes was related to a decline in potency (p = 0.05), but neither smoking nor hypertension were. For patients with optimal potency at baseline, mean sexual bother scores had declined significantly at 1 year (p < 0.01). Sexual potency, sexual function, and sexual bother scores failed to correlate with any dosimetric variable tested. Conclusions: Erections firm enough for intercourse can be achieved at 1 year after treatment, but most men will require medical aids to optimize potency. Although younger men were better able to maintain erections firm enough for intercourse than older men, there was no correlation between potency, sexual function, or sexual bother and penile bulb dosimetry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Twelve-Month Prostate-Specific Antigen Values and Perineural Invasion as Strong Independent Prognostic Variables of Long-Term Biochemical Outcome After Prostate Seed Brachytherapy

Purpose: To determine whether post-treatment prostate-specific antigen (ptPSA) values at 12 months and other clinical parameters predict long-term PSA relapse-free survival (PRFS) following prostate seed brachytherapy. Methods and Materials: Records of 204 hormone-naieve patients with localized adenocarcinoma of the prostate treated at St. Mary's Regional Medical Center in Reno, NV, and at Carson Tahoe Regional Medical Center in Carson City, NV, between 1998 and 2003, using I-125 or Pd-103 seed brachytherapy, were retrospectively analyzed. Treatment planning was done using a preplanned, modified peripheral loading technique. A total of 185 of 204 patients had PSA records at 12 months after implant. Variables included were age, initial pretreatment PSA, Gleason score, T stage, National Comprehensive Cancer Network (NCCN) risk group (RG), perineural invasion (PNI), external beam boost, dose, and ptPSA levels at 12 months with cutpoints at {<=}1, 1.01 to 2.00, 2.01 to 3.00, and >3.00 ng/ml. Results: Median follow-up was 80 months, and median age was 69 years. The numbers of patients stratified by NCCN low, intermediate, and high RG were 110:65:10, respectively. Monotherapy and boost prescription doses were 145 Gy and 110 Gy for I-125, and 125 Gy and 100 Gy for Pd-103 seeds, respectively. The median dose (D90) was 95.4% of the prescribed dose. The 5-year PRFS at the 12-months ptPSA levels of {<=}1, 1.01 to 2.00, 2.01 to 3.00, and >3.00 ng/ml were 98.5%, 85.7%, 61.5%, and 22.2%, respectively. The 10-year PRFS at the 12-months ptPSA levels of {<=}1 and 1.01 to 2.00 ng/ml were 90.5% and 85.7%, respectively. In multivariate analysis, both ptPSA and PNI were significant independent predictors of PRFS. Hazard ratios (HR) for ptPSA levels at {<=}1, 1.01 to 2.00, 2.01 to 3.00, and >3.00 ng/ml at 12 months were 1, 4.96, 27.57, and 65.10, respectively. PNI had an HR of 6.1 (p = 0.009). Conclusions: Presence of PNI and ptPSA values at 12 months are strong prognostic variables for long-term PRFS after definitive prostate brachytherapy seed implantation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantifying the Impact of Immediate Reconstruction in Postmastectomy Radiation: A Large, Dose-Volume Histogram-Based Analysis

Purpose: To assess the impact of immediate breast reconstruction on postmastectomy radiation (PMRT) using dose-volume histogram (DVH) data. Methods and Materials: Two hundred forty-seven women underwent PMRT at our center, 196 with implant reconstruction and 51 without reconstruction. Patients with reconstruction were treated with tangential photons, and patients without reconstruction were treated with en-face electron fields and customized bolus. Twenty percent of patients received internal mammary node (IMN) treatment. The DVH data were compared between groups. Ipsilateral lung parameters included V20 (% volume receiving 20 Gy), V40 (% volume receiving 40 Gy), mean dose, and maximum dose. Heart parameters included V25 (% volume receiving 25 Gy), mean dose, and maximum dose. IMN coverage was assessed when applicable. Chest wall coverage was assessed in patients with reconstruction. Propensity-matched analysis adjusted for potential confounders of laterality and IMN treatment. Results: Reconstruction was associated with lower lung V20, mean dose, and maximum dose compared with no reconstruction (all P<.0001). These associations persisted on propensity-matched analysis (all P<.0001). Heart doses were similar between groups (P=NS). Ninety percent of patients with reconstruction had excellent chest wall coverage (D95 >98%). IMN coverage was superior in patients with reconstruction (D95 >92.0 vs 75.7%, P<.001). IMN treatment significantly increased lung and heart parameters in patients with reconstruction (all P<.05) but minimally affected those without reconstruction (all P>.05). Among IMN-treated patients, only lower lung V20 in those without reconstruction persisted (P=.022), and mean and maximum heart doses were higher than in patients without reconstruction (P=.006, P=.015, respectively). Conclusions: Implant reconstruction does not compromise the technical quality of PMRT when the IMNs are untreated. Treatment technique, not reconstruction, is the primary determinant of target coverage and normal tissue doses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proton Therapy for Breast Cancer After Mastectomy: Early Outcomes of a Prospective Clinical Trial

Purpose: Dosimetric planning studies have described potential benefits for the use of proton radiation therapy (RT) for locally advanced breast cancer. We report acute toxicities and feasibility of proton delivery for 12 women treated with postmastectomy proton radiation with or without reconstruction. Methods and Materials: Twelve patients were enrolled in an institutional review board-approved prospective clinical trial. The patients were assessed for skin toxicity, fatigue, and radiation pneumonitis during treatment and at 4 and 8 weeks after the completion of therapy. All patients consented to have photographs taken for documentation of skin toxicity. Results: Eleven of 12 patients had left-sided breast cancer. One patient was treated for right-sided breast cancer with bilateral implants. Five women had permanent implants at the time of RT, and 7 did not have immediate reconstruction. All patients completed proton RT to a dose of 50.4 Gy (relative biological effectiveness [RBE]) to the chest wall and 45 to 50.4 Gy (RBE) to the regional lymphatics. No photon or electron component was used. The maximum skin toxicity during radiation was grade 2, according to the Common Terminology Criteria for Adverse Events (CTCAE). The maximum CTCAE fatigue was grade 3. There have been no cases of RT pneumonitis to date. Conclusions: Proton RT for postmastectomy RT is feasible and well tolerated. This treatment may be warranted for selected patients with unfavorable cardiac anatomy, immediate reconstruction, or both that otherwise limits optimal RT delivery using standard methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mechanical and degradation property improvement in a biocompatible Mg-Ca-Sr alloy by thermomechanical processing

Magnesium-based alloys have attracted interest as a potential material to comprise biomedical implants that are simultaneously high-strength and temporary, able to provide stabilization before degrading safely and able to be excreted by the human body. Many alloy systems have been evaluated, but this work reports on improved properties through hot extrusion of one promising alloy: Mg-1.0 wt% Ca-0.5 wt%Sr. This alloy has previously demonstrated promising toxicity and degradation properties in the as-cast and rolled conditions. In the current study extrusion causes a dramatic improvement in the mechanical properties in tension and compression, as well as a low in vitro degradation rate. Microstructure (texture, second phase distribution, and grain size), bulk mechanical properties, flow behavior, degradation in simulated body fluid, and effect on osteoblast cyctotoxicity are evaluated and correlated to extrusion temperature. In conclusion, maximum yield strength of 300 MPa (above that of annealed 316 stainless steel) with 10% elongation is observed, making this alloy competitive with existing implant materials.

36 MATERIALS SCIENCE↗

Direct hydrothermal synthesis of hydroxyapatite/alumina nanocomposite

Hydrothermal synthesis offers numerous advantages such as: control over product homogeneity, nucleation, growth and aging. This leads to the control of particle aggregation, size uniformity and morphology over conventional and non-conventional ceramic synthesis methods. In the present work, a novel procedure for the direct synthesis of Hydroxyapatite (HAp)/alumina nanocomposite in a hydrothermal vessel with continuous stirring was investigated, where the effects of different concentration of aluminium nitrate were also studied. The optimized concentration of starting material for the characteristic formation of HAp/alumina composite (hexagonal HAp and monoclinic alumina phases) was determined by X-ray diffraction (XRD) study. The size distribution of HAp/alumina composite was found as 100 nm by electron microscopy and EDAX revealed that the concentration of alumina in the HA4 was ~ 10%, which is more suitable for biomedical implant. Further, the cytotoxicity study against MG 63 cells showed that HA4 was biocompatible even at higher concentration (200 μg/ml). Hence, the direct synthesis of HAp/alumina composite without the formation of any intermediate like calcium aluminate could be used as a novel approach to prepare HAp based biomedical implants.

36 MATERIALS SCIENCE↗

Dosimetric differences between intraoperative and postoperative plans using Cs-131 in transrectal ultrasound–guided brachytherapy for prostatic carcinoma

The aim of the study was to investigate the differences between intraoperative and postoperative dosimetry for transrectal ultrasound–guided transperineal prostate implants using cesium-131 ({sup 131}Cs). Between 2006 and 2010, 166 patients implanted with {sup 131}Cs had both intraoperative and postoperative dosimetry studies. All cases were monotherapy and doses of 115 were prescribed to the prostate. The dosimetric properties (D{sub 90}, V{sub 150}, and V{sub 100} for the prostate) of the studies were compared. Two conformity indices were also calculated and compared. Finally, the prostate was automatically sectioned into 6 sectors (anterior and posterior sectors at the base, midgland, and apex) and the intraoperative and postoperative dosimetry was compared in each individual sector. Postoperative dosimetry showed statistically significant changes (p < 0.01) in every dosimetric value except V{sub 150}. In each significant case, the postoperative plans showed lower dose coverage. The conformity indexes also showed a bimodal frequency distribution with the index indicating poorer dose conformity in the postoperative plans. Sector analysis revealed less dose coverage postoperatively in the base and apex sectors with an increase in dose to the posterior midgland sector. Postoperative dosimetry overall and in specific sectors of the prostate differs significantly from intraoperative planning. Care must be taken during the intraoperative planning stage to ensure complete dose coverage of the prostate with the understanding that the final postoperative dosimetry will show less dose coverage.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evolution of brachytherapy treatment planning to deterministic radiation transport for calculation of cardiac dose

Brachytherapy was among the first methods of radiotherapy and has steadily continued to evolve. Here we present a brief review of the progression of dose calculation methods in brachytherapy to the current state-of-the art computerized methods for heterogeneity correction. We further review the origin and development of the BrachyVision (Varian Medical Systems, Inc., Palo Alto, CA) treatment planning system and evaluate dosimetric results from 12 patients implanted with the strut-assisted volumetric implant (SAVI) applicator (Cianna Medical, Aliso Viejo, CA) for accelerated partial breast irradiation (APBI). Dosimetric results from plans calculated using homogenous and heterogeneous algorithms have been compared to investigate the impact of heterogeneity corrections. Our study showed large percent difference between mean cardiac doses 11.8 ± 6.2% (p = 0.0007) calculated with and without heterogeneity corrections. Our findings are consistent with those of others, indicating an overestimation of the distal dose to organs-at-risk by traditional methods, especially at interfaces between air and tissue.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimization of a low noise detection circuit for probing the structure of damage cascades with IBIC

Optimal detector / pre-amplifier combinations have been identified for the use of light ion IBIC (ion beam induced charge) to probe the physical structure of electrically active defects in damage cascades caused by heavy ion implantation. The ideal detector must have a sufficiently thin dead layer that incident ions will produce the majority of damage cascades in the depletion region of the detector rather than the dead layer. Detector and circuit noise must be low enough to detect the implantation of a single heavy ion as well as the decrease in the light ion IBIC signal caused by Shockley-Read-Hall recombination when the beam scans regions of the detector damaged by the heavy ion. The IBIC signals from three detectors irradiated with 750 keV He⁺ ions are measured with commercial and bespoke charge sensitive pre-amplifiers to identify the combination with the lowest noise.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗