Maskless implants of 20 keV Ga{sup +} in thin crystalline silicon on insulator

A nano-sized ion beam apparatus has been used as maskless lithography to implant 20 keV Ga{sup +} ions into a 26 nm thick silicon crystalline film on insulator. The ion beam, with about 5 nm standard deviation, delivered few hundred ions during a single shot. Circular areas with nominal diameter of 20 or 50 nm were irradiated to a fluence of 5 Multiplication-Sign 10{sup 14}/cm{sup 2}. Transmission electron microscopy evidenced that the damaged regions are characterized by an irregular contour with many disordered filaments. Damage extends across the layer thickness and fast Fourier transform analysis indicates that implantation causes the amorphization of a region which extends beyond the nominal diameter. In situ annealing experiments demonstrated that the disordered filamentary regions disappear in the 250-450 Degree-Sign C temperature range and the interfaces with the surrounding crystalline regions sharpen. A temperature as high as 600 Degree-Sign C is required to fully re-crystallize the amorphous core of the implanted dots. Reordering occurs by multi-orientation lateral solid-phase epitaxial growth and the breaking of (111) and (101) interfaces, due to the formation of twins, triggers a fast crystallization kinetics. Rapid thermal annealing (890 Degree-Sign C-10 s) completely crystallizes the amorphous regions, twins are absent and small cluster of defects remains instead. Preliminary scanning capacitance measurements indicate that the implanted atoms, after crystallization, are electrically active. The implant method is then a viable processing step for the doping of non-bulk fully depleted ultra-thin-body MOSFET.

36 MATERIALS SCIENCE↗

Structure and magnetic properties of irradiated Fe/Fe oxide core-shell nanoclusters

A cluster deposition method was used to produce a film of loosely aggregated particles of Fe-Fe3O4 core-shell nanoclusters with an 8 nm iron core size and 2 nm oxide shell thickness. The film of particles on a silicon substrate was irradiated with 5.5 MeV Si2+ ions to a fluence of 1016 cm-2 near room temperature, and computer simulations based on the SRIM (Stopping and Range of Ions in Matter) code show that the implanted Si species stops near the film-substrate interface. The ion irradiation creates a structural change in the film with corresponding chemical and magnetic changes. X-ray diffraction shows that the core size and chemistry stay the same but the shell becomes FeO that grows to a thickness of 17 nm. Helium ion microscopy shows that the previously separate particles have densified into a nearly continuous film. Major loop magnetic hysteresis measurements show a decrease in saturation magnetization that we attribute to the presence of the antiferromagnetic (AFM) FeO shell. First-order reversal curve measurements on the irradiated film performed with a vibrating sample magnetometer show that the AFM shell prevents the particles from interacting magnetically, leading to low coercivity from the iron core and little bias field from the core interactions. These results, and others reported previously on different compositions (Fe3O4 or FeO+Fe3N nanoclusters), show that the ion irradiation behavior of nanocluster films such as these depends strongly on the initial nanostructure and chemistry.

Environmental Molecular Sciences Laboratory↗

Temperature-dependent cavity swelling in dual-ion irradiated Fe and Fe-Cr ferritic alloys

Fe-Cr ferritic-martensitic (FM) steels are promising structural material candidates for fusion and advanced fission reactors due to their attractive mechanical properties and volumetric swelling resistance. However, significant discrepancies exist regarding the effect of solutes and irradiation temperature on cavity swelling under ion versus neutron irradiation conditions. In this study, simultaneous dual ion irradiations (8 MeV Ni 3+ ions and energy-degraded 3.5 MeV He 2+ ions) were used to quantify the cavity swelling behavior in ultra-high purity Fe and Fe-Cr alloys (3-14 wt.% Cr), Fe-10 wt.% Cr-780 wt.ppm C, and Eurofer97 FM steel. The irradiations were conducted over a wide temperature range (400-550°C) with a mid-range dose of ~30 displacements per atom (dpa) and 0.1 appm/dpa He implantation rate. Here, using state-of-the-art transmission electron microscopy (TEM), we reveal that pure Fe has a ~50°C lower peak swelling temperature difference than Fe-Cr alloys, which is attributed to higher vacancy mobility in pure Fe. Chromium solute appears to strongly suppress cavity swelling in Fe-Cr alloys for temperatures below ~470°C, but seems to have little effect or slightly enhances swelling above ~470°C. Cavities were observed in all the irradiated samples between 400-550°C. This indicates that the narrow temperature range of observable cavities reported in prior ion irradiated Fe-Cr ferritic alloy studies is likely an artifact associated with the use of low ion energies (<5 MeV), which leads to pronounced near-surface and implanted ion effects that suppress cavity swelling even at midrange depths (particularly at high temperatures).

36 MATERIALS SCIENCE↗

Contorted acene ribbons for stable and ultrasensitive neural probes

Organic materials that conduct both electrons and ions are integral to implantable bioelectronics because of their conformable nature. There is a dearth of these materials that are highly sensitive to cations, which are the majority ions on the surface of neurons. This manuscript offers a solution using an extended ribbon structure that is defect-free, providing high electronic mobility along its fused backbone, while the edge structure of these ribbons promotes high ionic conductivity. We incorporated these mixed ion/electron conductors into neural probes and implanted them in a rodent brain where they offer a suite of useful properties: high cation sensitivity, stability over several weeks after implantation, and biocompatibility. These materials represent an innovative class of implantable biosensors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ion-Beam Synthesis of the Crystalline Ge Phase in SiO{sub x}N{sub y} Films upon Annealing under High Pressure

The nucleation of the crystalline Ge phase in SiO{sub x}N{sub y} films implanted with Ge{sup +} ions with the energy 55 keV to doses of 2.1 × 10{sup 15}–1.7 × 10{sup 16} cm{sup –2} and then annealed at a temperature of T{sub a} = 800–1300°C under pressures of 1 bar and 1–12 kbar is studied. From analysis of the Raman spectra, it is concluded that amorphous Ge precipitates increase in size upon hydrostatic compression at a temperature of 1000°C. Raman scattering at optical phonons localized in Ge nanocrystals is observed only after annealing of the samples with the highest content of implanted atoms at a temperature of 1300°C. In the photoluminescence spectra, a peak is observed at the wavelength ∼730 nm. The peak is considered to be the manifestation of the quantum-confinement effect in nanocrystals ∼3 nm in size.

36 MATERIALS SCIENCE↗

Atomistic simulation of Er irradiation induced defects in GaN nanowires

Classical molecular dynamics simulation was used to irradiate a GaN nanowire with rear-earth erbium (Er). Ten cumulative irradiations were done using an ion energy of 37.5 keV on a 10 × 10 nm²surface area which corresponds to a fluence of 1 × 10¹³ cm⁻². We studied the location and types of defects produced in the irradiation. Er implantation leads to a net positive (expansion) strain in the nanowire and especially at the top region a clear expansion has been observed in the lateral and axial directions. The lattice expansion is due to the hydrostatic strain imposed by a large number of radiation induced defects at the top of the NW. Due to the large surface-to-volume ratio, most of the defects were concentrated at the surface region, which suggests that the experimentally observed yellow luminescence (YL) in ion implanted GaN NWs arises from surface defects. We observed big clusters of point defects and vacancy clusters which are correlated with stable lattice strain and the YL band, respectively.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Distribution and Characterization of Iron in Implanted Silicon Carbide

Analytical electron microscopy (AEM) and Rutherford backscattering spectroscopy-ion channeling (RBS-C) have been used to characterize single crystal 6h-silicon carbide implanted at room temperature with 160 keV 57 Fe ions to fluences of 1, 3, and 6 x 10 16 ions/cm 2 . Best correlations among AEM, RBS, and TRIM calculations were obtained assuming a density of the amorphized implanted regions equal to that of crystalline SiC. No iron-rich precipitates or clusters were detected by AEM. Inspection of the electron energy loss fine structure for iron in the implanted specimens suggests that the iron is not metallically-bonded, supporting conclusions from earlier conversion electron Mössbauer spectroscopy (CEMS) studies. In-situ annealing surprisingly resulted in crystallization at 600°C with some redistribution of the implanted iron.

36 MATERIALS SCIENCE↗

Solar Ion Processing of Itokawa Grains: Reconciling Model Predictions with Sample Observations

Analytical TEM observations of Itokawa grains reported to date show complex solar wind ion processing effects in the outer 30-100 nm of pyroxene and olivine grains. The effects include loss of long-range structural order, formation of isolated interval cavities or "bubbles", and other nanoscale compositional/microstructural variations. None of the effects so far described have, however, included complete ion-induced amorphization. To link the array of observed relationships to grain surface exposure times, we have adapted our previous numerical model for progressive solar ion processing effects in lunar regolith grains to the Itokawa samples. The model uses SRIM ion collision damage and implantation calculations within a framework of a constant-deposited-energy model for amorphization. Inputs include experimentally-measured amorphization fluences, a Pi steradian variable ion incidence geometry required for a rotating asteroid, and a numerical flux-versus-velocity solar wind spectrum.

Christoffersen, Roy↗

Optical switching and photoluminescence in erbium-implanted vanadium dioxide thin films

Vanadium dioxide (VO{sub 2}) is under intensive consideration for optical switching due to its reversible phase transition, which features a drastic and rapid shift in infrared reflectivity. Classified as an insulator–to–metal transition, the phase transition in VO{sub 2} can be induced thermally, electrically, and optically. When induced optically, the transition can occur on sub-picosecond time scales. It is interesting to dope VO{sub 2} with erbium ions (Er{sup 3+}) and observe their combined properties. The first excited-state luminescence of Er{sup 3+} lies within the wavelength window of minimal transmission-loss in silicon and has been widely utilized for signal amplification and generation in silicon photonics. The incorporation of Er{sup 3+} into VO{sub 2} could therefore result in a novel photonic material capable of simultaneous optical switching and amplification. In this work, we investigate the optical switching and photoluminescence in Er-implanted VO{sub 2} thin films. Thermally driven optical switching is demonstrated in the Er-implanted VO{sub 2} by infrared reflectometry. Photoluminescence is observed in the thin films annealed at ∼800 °C or above. In addition, Raman spectroscopy and a statistical analysis of switching hysteresis are carried out to assess the effects of the ion implantation on the VO{sub 2} thin films. We conclude that Er-implanted VO{sub 2} can function as an optical switch and amplifier, but with reduced switching quality compared to pure VO{sub 2}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Diffusion and impurity segregation in hydrogen-implanted silicon carbide

Diffusion and segregation behavior of hydrogen and oxygen in silicon carbide subjected to H implantation and subsequent annealing were studied with a number of analytical techniques including Secondary Ion Mass Spectrometry (SIMS), Rutherford backscattering spectrometry in channeling geometry, field emission scanning electron microscopy, optical microscopy, cross-sectional transmission electron microscopy, and atomic force microscopy. H{sup +} implantation was carried out with energies of 200 keV, 500 keV, or 1 MeV to doses of 1 × 10{sup 16}, 1 × 10{sup 17}, or 2 × 10{sup 17} ion/cm{sup 2}, and thermal treatment was conducted in flowing argon for 1 to 2 h at temperatures of 740, 780, 1000, or 1100 °C. The process of migration and eventual loss of hydrogen in a point defect regime is postulated to proceed to a large extent through ionized vacancies. This conclusion was derived from the observed substantial difference in H mobilities in n- vs. p-type SiC as the population of ionized vacancies is governed by the Fermi-Dirac statistics, i.e., the position of the Fermi level. For higher doses, a well defined buried planar zone forms in SiC at the maximum of deposited energy, comprising numerous microvoids and platelets that are trapping sites for hydrogen atoms. At a certain temperature, a more or less complete exfoliation of the implanted layer is observed. For a 1 MeV implant heated to 1100 °C in nominally pure argon, SIMS profiling reveals a considerable oxygen peak of 10{sup 16} O atoms/cm{sup 2} situated at a depth close to that of the peak of the implanted H{sup +}. Similarly, 1100 °C annealing of a 200 keV implant induces the formation of a thin oxide (4 nm), located at the interface between the implanted layer and the substrate as evidenced by both SIMS and HRTEM. The measurements were taken on the part of the sample that remained un-exfoliated. In view of a lack of convincing evidence that a hexagonal SiC might contain substantial amounts of oxygen, further investigation is under way to elucidate its presence in the irradiation-damaged films.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fabrication of Impregnated-Electrode-Type Polyatomic Ion Source with Ionic Liquid

Three types of ionic liquid ion source characterized by needle-type, capillary-needle-type and impregnated-electrode-type emitters were fabricated and demonstrated. The ion emission of a pure ionic liquid was demonstrated for the capillary-needle- and impregnated-electrode-type emitters. The emission stability of the impregnated-electrode-type emitter is currently insufficient for the shallow implantation of carbon due to occasional discharge. However, the impregnated-electrode-type emitter showed the largest emission current of 14 {mu}A at 6 kV among these emitters. This was considered to be caused by the relatively high feedability of the ionic liquid obtained from the emitter tip made of porous copper.

43 PARTICLE ACCELERATORS↗

Predictive process simulation of cryogenic implants for leading edge transistor design

Two cryogenic implant TCAD-modules have been developed: (i) A continuum-based compact model targeted towards a TCAD production environment calibrated against an extensive data-set for all common dopants. Ion-specific calibration parameters related to damage generation and dynamic annealing were used and resulted in excellent fits to the calibration data-set. (ii) A Kinetic Monte Carlo (kMC) model including the full time dependence of ion-exposure that a particular spot on the wafer experiences, as well as the resulting temperature vs. time profile of this spot. It was calibrated by adjusting damage generation and dynamic annealing parameters. The kMC simulations clearly demonstrate the importance of the time-structure of the beam for the amorphization process: Assuming an average dose-rate does not capture all of the physics and may lead to incorrect conclusions. The model enables optimization of the amorphization process through tool parameters such as scan speed or beam height.

36 MATERIALS SCIENCE↗

Additively manufactured refractory high-entropy alloys with superior radiation resistance

Refractory high-entropy alloys (RHEAs) are promising candidates for next-generation nuclear and high-temperature applications. Among many approaches to manufacture RHEAs, additive manufacturing (AM) represents the most recent and advanced metal manufacturing method which allows near-net-shape manufacturing to reduce material waste and post-processing time. However, performance of AM RHEAs under complex irradiation conditions remains largely unexplored. Here, in this study, we demonstrate for the first time the response of directed energy deposition (DED) AM quaternary RHEAs (HfTaVW, CrTaVW) subjected to sequential dual-beam ion irradiation, consisting of helium pre-implantation followed by high-dose heavy ion bombardment. Compositions of DED AM RHEAs were selected using Monte Carlo (MC) simulations based on a cluster expansion (CE) Hamiltonian parameterized by density functional theory (DFT). Post-irradiation microstructural characterization revealed that the AM RHEA maintained remarkable stability, with suppressed helium bubble growth and reduced defect accumulation compared to conventional alloys. Even at high doses (∼100 dpa), the alloy exhibited no void swelling, a low density of dislocation loops, and no evidence of severe degradation. These results highlight the intrinsic ability of AM-derived microstructures and multicomponent chemistry to synergistically mitigate irradiation effects. Our findings establish AM RHEAs as a class of materials with superior resistance to radiation damage under conditions relevant to advanced fusion and fission environments and demonstrate the importance of sequential ion beam studies in evaluating their long-term performance.

36 MATERIALS SCIENCE↗

First experiments with Cs doped Mo as surface converter for negative hydrogen ion sources

A study was conducted on the properties of molybdenum implanted with caesium as an approach to reduce the Cs consumption of negative hydrogen ion sources based on evaporated Cs. The depth profiles of the implanted Cs were simulated by SDTrimSP and experimentally determined by X-ray photoelectron spectroscopy depth profiling. In particular, one year after implantation, the depth profiles showed no signs of Cs diffusion into the molybdenum, suggesting long term stability of the implanted Cs atoms. The H{sup −} surface generation mechanisms on the implanted samples in hydrogen plasma were investigated, and the stability of the H{sup −} yield during four hours low power hydrogen plasma discharges was demonstrated. An estimation of the work function reduction (−0.8 eV) by the Cs implantation was performed, and a comparison of the relative negative ion yields between the implanted samples and highly oriented pyrolitic graphite showed that the Cs doped Mo negative ion yield was larger.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Benefits of Damage Engineering for PMOS Junction Stability

As CMOS devices continue to shrink, the formation of ultra shallow junction (USJ) in the source/drain extension remains to be a key challenge requiring high dopant activation, shallow dopant profile and abrupt junctions. The next generations of sub nano-CMOS devices impose a new set of challenges such as elimination of residual defects resulting in higher leakage, difficulty to control lateral diffusion, junction stability post anneal and junction formation in new materials. To address these challenges for advanced technological nodes beyond 32 nm, it is imperative to explore novel species and techniques. Molecular species such as Carborane (C{sub 2}B{sub 10}H{sub 12}), a novel doping species and a promising alternative to monomer Boron is of considerable interest due to the performance boost for 22 nm low power and high performance devices. Also, to reduce residual defects, damage engineering methodologies have generated a lot of attention as it has demonstrated significant benefits in device performance. Varian proprietary techniques to perform implants at cold temperatures (PTC II) have demonstrated lower junction leakage, enhanced activation, reduced dopant diffusion and less dopant deactivation due to the reduction of self-interstitial atoms present at the end-of-range (EOR) with low implant temperatures. In this paper, for the first time, there is a comprehensive study of the effect of implant temperature on defect engineering affecting deactivation/reactivation, and it is well established in this paper that colder the implant temperature the better it is for damage engineering with reduced EOR defects and better amorphization. The effect has been studied over a wide range of implant temperature. To understand any difference in deactivation between molecular and monomer Boron and to provide direct comparison equivalent Boron implants, co-implanted with Carbon were also studied. Implants with wide range of temperatures are implemented using PTC II. This paper will also show how damage reduction correlates with optimum junction formation and stability.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microstructural evolution in H ion induced splitting of freestanding GaN

We investigated the microstructural transformations during hydrogen ion-induced splitting of GaN thin layers. Cross-sectional transmission electron microscopy and positron annihilation spectroscopy data show that the implanted region is decorated with a high density of 1-2 nm bubbles resulting from vacancy clustering during implantation. These nanobubbles persist up to 450 deg. C. Ion channeling data show a strong dechanneling enhancement in this temperature range tentatively attributed to strain-induced lattice distortion. The dechanneling level decreases following the formation of plateletlike structures at 475 deg. C. Extended internal surfaces develop around 550 deg. C leading to the exfoliation of GaN thin layer.

36 MATERIALS SCIENCE↗

Revealing the synergistic effects of sequential and simultaneous dual beam irradiations in tungsten via in-situ TEM

Elucidating the synergistic effects of different energetic beams on the radiation response of nuclear materials is critical for developing an improved methodology for their evaluation when exposed to extreme environments. This article describes in-situ sequential (He implantation followed by Kr irradiation and vice-versa) and simultaneous (heavy ion Kr irradiation and He implantation) dual beam irradiations performed on tungsten at 1223 K. Dislocation loop density, average area, and total loop damage as a function of irradiation history and dose/fluence are quantified. The loop Burgers vectors and cavity damage (cavity density, size and total change in volume) are also determined at the final maximum dose for each condition. The loop damage evolution was different in all cases, with the smallest loop damage observed in the simultaneous experiment. Annihilation of Kr generated dislocation loops during He implantation in the Kr + He experiment was an unanticipated observation that may be explained by the dynamic evolution of dislocation loop sink strengths and time-dependent defect fluxes. Dislocation loop raft formation, denuded zones near extended defects, and cavity damage are compared across the different conditions. The phenomena observed and discussed in this work will stimulate further experimental and computational modeling activities leading to improved fundamental understanding of the irradiation response of nuclear materials under reactor-similar environments.

36 MATERIALS SCIENCE↗

Blister resistant targets for nuclear reaction experiments with α-particle beams

Solid targets for nuclear measurements that use α-particle beams commonly experience a form of degradation known as blistering. The effect can prevent the use of solid targets for high intensity α-particle experiments, often necessitating complex gas target systems. To combat this problem, three different blister resistant target backings were designed for use in direct reaction measurements with high intensity α-particle beams. The blister resistant target designs utilize gas diffusive properties of fused silica, sintered metal, and porous evaporated metal. Each target was implanted with 22 Ne ions and bombarded with α-particle beam to test blister resistance. Targets were characterized and monitored using the 22 Ne(p, γ) 23 Na reaction to determine the degradation of implanted material, and compare them to typical implanted noble gas targets. We find that all targets studied exhibit resistance to blistering, with the porous evaporated metal targets displaying the least amount of target material degradation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗