Subscale hot-fire testing of a formed platelet liner

To investigate low-cost options for fabricating main combustion chambers, formed platelet liners are being developed. The savings in manufacturing time and cost associated with platelet liners are accompanied by promising thermal advantages, such as lower-wall temperatures and increased cycle life. A subscale liner was tested by NASA at Marshall Space Flight Center (MSFC) to demonstrate its thermal performance. Testing to date has provided chamber pressures up to 2524 psia, while a maximum chamber pressure of 2700 psia is planned. In general, the liner has remained in good condition and performed well, with only minor areas of localized roughening. Data from this subscale test program is being used to develop a full size chamber for testing on a Space Shuttle Main Engine at MSFC in 1994.

Elam, Sandra K.↗

Flexural Fatigue Testing and Qualification of Hybrid PAN-pitch Composite Materials with High Through-Thickness Thermal Conductivity

Carbon-fiber-reinforced polymers (CFRPs) considered for motor components within future electric vertical takeoff and landing (eVTOL) vehicles require not only a high strength-to-weight ratio but also a high through-thickness thermal conductivity (TC) to dissipate heat. Previously, CFRPs incorporating pitch CF interleaves demonstrated an increased through-thickness TC relative to the baseline composite, but the effect on flexural fatigue life was not evaluated. For this work, T700S/TC275–1 braided carbon fiber/epoxy prepreg baseline (no interleave), YSH–60A pitch interleave, and YS–80A pitch interleave configurations were tested for fatigue life. A combination of ASTM International Standards D7264 and D3479 were used to develop a reliable testing method. An Instron® (Illinois Tool Works Inc.) 8501 servohydraulic system with a fatigue test fixture was set up with a 16:1 span:thickness ratio, load ratio R set to 0.1, and frequency of 4 Hz. High-cycle fatigue testing was completed, and it was found that YSH–60A interleave performed slightly better than YS–80A below 100,000 cycles but showed no differences above 100,000 cycles. In all cases, the baseline CFRP had superior fatigue life performance both in terms of stress handled and total cycles to failure. These fatigue testing data will inform future use of hybrid CFRP materials by highlighting the tradeoff between increased through-thickness TC and fatigue life. Testing guidelines, equipment, and parameters for static and fatigue tests were successfully outlined for CFRPs.

composites↗

Life Limiting Behavior in Interlaminar Shear of Continuous Fiber-Reinforced Ceramic Matrix Composites at Elevated Temperatures

Interlaminar shear strength of four different fiber-reinforced ceramic matrix composites was determined with doublenotch shear test specimens as a function of test rate at elevated temperatures ranging from 1100 to 1316 C in air. Life limiting behavior, represented as interlaminar shear strength degradation with decreasing test rate, was significant for 2-D crossplied SiC/MAS-5 and 2-D plain-woven C/SiC composites, but insignificant for 2-D plain-woven SiC/SiC and 2-D woven Sylramic (Dow Corning, Midland, Michigan) SiC/SiC composites. A phenomenological, power-law delayed failure model was proposed to account for and to quantify the rate dependency of interlaminar shear strength of the composites. Additional stress rupture testing in interlaminar shear was conducted at elevated temperatures to validate the proposed model. The model was in good agreement with SiC/MAS-5 and C/SiC composites, but in poor to reasonable agreement with Sylramic SiC/SiC. Constant shear stress-rate testing was proposed as a possible means of life prediction testing methodology for ceramic matrix composites subjected to interlaminar shear at elevated temperatures when short lifetimes are expected.

Choi, Sung R.↗

Environmental Testing of Tritium-Phosphor Glass Vials for Use in Long-Life Radioisotope Power Conversion Units

Power generation in extreme environments, such as the outer solar system, the night side of planets, or other low-illumination environments, currently presents a technology gap that challenges NASA's ambitious scientific goals. We are developing a radioisotope power cell (RPC) that utilizes commercially available tritium light sources and standard 1.85 eV InGaP2 photovoltaic cells to convert beta particle energy to electric energy. In the test program described here, we perform environmental tests on commercially available borosilicate glass vials internally coated with a ZnS luminescent phosphor that are designed to contain gaseous tritium in our proposed power source. Such testing is necessary to ensure that the glass containing the radioactive tritium is capable of withstanding the extreme environments of launch and space for extended periods of time.

Zemcov, Michael↗

Hydrogen depolarized carbon dioxide concentrator performance improvements and cell pair structural tests

The investigations and testing associated with the CO2 removal efficiency and voltage degradation of a hydrogen depolarized carbon oxide concentrator are reported. Also discussed is the vibration testing of a water vapor electrolysis cell pair. Performance testing of various HDC cell pairs with Cs2CO3 electrolyte provided sufficient parametric and endurance data to size a six man space station prototype CO2 removal system as having 36 HDC cell pairs, and to verify a life capability exceeding six moths. Testing also demonstrated that tetramethylammonium carbonate is an acceptable HDC electrolyte for operating over the relative humidity range of 30 to 90 percent and over a temperature range of 50 to 80 F.

Huddleston, J. D.↗

Testing, Requirements, and Metrics

The criticality of correct, complete, testable requirements is a fundamental tenet of software engineering. Also critical is complete requirements based testing of the final product. Modern tools for managing requirements allow new metrics to be used in support of both of these critical processes. Using these tools, potential problems with the quality of the requirements and the test plan can be identified early in the life cycle. Some of these quality factors include: ambiguous or incomplete requirements, poorly designed requirements databases, excessive or insufficient test cases, and incomplete linkage of tests to requirements. This paper discusses how metrics can be used to evaluate the quality of the requirements and test to avoid problems later. Requirements management and requirements based testing have always been critical in the implementation of high quality software systems. Recently, automated tools have become available to support requirements management. At NASA's Goddard Space Flight Center (GSFC), automated requirements management tools are being used on several large projects. The use of these tools opens the door to innovative uses of metrics in characterizing test plan quality and assessing overall testing risks. In support of these projects, the Software Assurance Technology Center (SATC) is working to develop and apply a metrics program that utilizes the information now available through the application of requirements management tools. Metrics based on this information provides real-time insight into the testing of requirements and these metrics assist the Project Quality Office in its testing oversight role. This paper discusses three facets of the SATC's efforts to evaluate the quality of the requirements and test plan early in the life cycle, thus preventing costly errors and time delays later.

Rosenberg, Linda↗

High-performance fiber/epoxy composite pressure vessels

Activities described include: (1) determining the applicability of an ultrahigh-strength graphite fiber to composite pressure vessels; (2) defining the fatigue performance of thin-titanium-lined, high-strength graphite/epoxy pressure vessel; (3) selecting epoxy resin systems suitable for filament winding; (4) studying the fatigue life potential of Kevlar 49/epoxy pressure vessels; and (5) developing polymer liners for composite pressure vessels. Kevlar 49/epoxy and graphite fiber/epoxy pressure vessels, 10.2 cm in diameter, some with aluminum liners and some with alternation layers of rubber and polymer were fabricated. To determine liner performance, vessels were subjected to gas permeation tests, fatigue cycling, and burst tests, measuring composite performance, fatigue life, and leak rates. Both the metal and the rubber/polymer liner performed well. Proportionately larger pressure vessels (20.3 and 38 cm in diameter) were made and subjected to the same tests. In these larger vessels, line leakage problems with both liners developed the causes of the leaks were identified and some solutions to such liner problems are recommended.

Chiao, T. T.↗

Materials selection for long life in low earth orbit - A critical evaluation of atomic oxygen testing with thermal atom systems

The use of thermal atom test methods as a materials selection and screening technique for low-earth orbit (LEO) spacecraft is critically evaluated. The chemistry and physics of thermal atom environments are compared with the LEO environment. The relative reactivities of a number of materials determined in thermal atom environments are compared with those observed in LEO and in high-quality LEO simulations. Reaction efficiencies (cu cm/atom) measured in a new type of thermal atom apparatus are one-thousandth to one ten-thousandth those observed in LEO, and many materials showing nearly identical reactivities in LEO show relative reactivities differing by as much as a factor of eight in thermal atom systems. A simple phenomenological kinetic model for the reaction of oxygen atoms with organic materials can be used to explain the differences in reactivity in different environments. Certain speciic thermal atom test environments can be used as reliable materials screening tools.

Koontz, S. L.↗

Effect of KOH concentration on LEO cycle life of IPV nickel-hydrogen flight cells. An update

An update of validation test results confirming the breakthrough in LEO cycle life of nickel-hydrogen cells containing 26 percent potassium hydroxide (KOH) electrolyte is presented. A breakthrough in the LEO cycle life of individual pressure vessel nickel-hydrogen cells is reported. The cycle life of boiler plate cells containing 26 percent KOH electrolyte was about 40,000 LEO cycles compared to 3500 cycles for cells containing 31 percent KOH.

Smithrick, John J.↗

Effect of KOH concentration on LEO cycle life of IPV nickel-hydrogen flight cells - An update

An update of validation test results confirming the breakthrough in LEO cycle life of nickel-hydrogen cells containing 26 percent potassium hydroxide (KOH) electrolyte is presented. A breakthrough in the LEO cycle life of individual pressure vessel nickel-hydrogen cells is reported. The cycle life of boiler plate cells containing 26 percent KOH electrolyte was about 40,000 LEO cycles compared to 3500 cycles for cells containing 31 percent KOH.

Smithrick, John J.↗

Mission perspectives

Handling the Martian samples by requiring that they be subjected to a complex protocol designed to detect life, which, if present, will then be assessed for its effects on terrestrial life forms is addressed. Sample testing must be performed within facilities that ensure that such Martian organisms cannot be accidentally introduced to Earth's biosphere during the assessment process. An Orbiting Quarantine Facility (OQF) designed to permit the detection and characterization of Martian life forms, while affording the Earth and its inhabitants the maximum level of protection, is analyzed and described.

Source record↗

An error-specific approach to testing

The main objective of software testing in the software development life cycle is to verify conformance of the implemented software with its intended requirements. Such requirements include system requirements, and programming requirements. Non-conformance with such requirements causes what are known as software errors. Specifying an appropriate testing strategy to expose software errors is still an art. Traditional approaches do succeed in revealing many errrors but none is powerful enough to expose all errors. The best that is hoped for is to use a specific test strategy to expose a specific error type in specific program locations. This limitation is exploited to develop a new approach to software testing which is called an error-specific testing (EST) strategy. Error specific testing is in fact a dual to the traditional testing approaches.

Valdes, P. M.↗

Gen 3 Particle Pilot Plant (G3P3) Life Cycle Management Plan (SAND report)

The National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories New Mexico (SNL/NM) developed this Life Cycle Management Plan (LCMP) to document its process for executing, monitoring, controlling and closing-out Phase 3 of the Gen 3 Particle Pilot Plant (G3P3). This plan serves as a resource for stakeholders who wish to be knowledgeable of project objectives and how they will be accomplished.

14 SOLAR ENERGY↗

Advanced Life Support

Viewgraphs on Advanced Life Support (ALS) Systems are presented. The topics include: 1) Fundamental Need for Advanced Life Support; 2) ALS organization; 3) Requirements and Rationale; 4) Past Integrated tests; 5) The need for improvements in life support systems; 6) ALS approach to meet exploration goals; 7) ALS Projects showing promise to meet exploration goals; and 9) GRC involvement in ALS.

Chambliss, Joe↗

Lipid Decontamination Procedures for Life Detection Missions

Molecular biosignatures are key targets for current, proposed, and future life detection missions. With the high accuracy and low limit of detection (LOD) that new and future instruments will require, decontamination of life detection hardware is necessary to prevent false positives. Lipids are a molecular biosignature of interest, as they are ubiquitous to all life as we know it, can survive unaltered in the geologic record for longer than any other biomolecule (i.e. billions of years), and form through both biotic and abiotic processes. Lipids display origin-diagnostic molecular patterns that can reveal biotic or abiotic synthesis, so finding them and ascertaining their molecular features is important for potentially detecting evidence of life elsewhere. Traditional methods of decontamination, or contamination control (CC), primarily clean hardware through fabrication in sterile (cleanroom) environments, killing microbes, and removing/flushing contaminants off instrument and spacecraft components. However, research suggests that some standard cleaning methods are either unlikely to remove lipid contaminants or are incompatible with life detection instrument materials. To solve this problem, I propose to find, test, and verify a decontamination method that thoroughly cleans instruments by destroying lipid molecules, but is simultaneously compatible with major materials used in these instruments. I will study the effects of traditional CC methods (including Dry Heat Microbial Reduction and Vapor phase Hydrogen Peroxide) and experimental CC methods (Electron Beam Irradiation) on lipid molecules for application to life detection instrumentation. I will then develop a CC plan for a novel lipid detector (ExCALiBR, Extractor for Chemical Analysis of Lipid Biomarkers in Regolith) searching for lipids in either soil or icy world scenarios. This plan will uphold planetary protection regulation requirements and validate experimental analyses of in-situ life detection tests.

Decontamination↗

Time dependency of strainrange partitioning life relationships

The effect of exposure time (or creep rate) on the CP life relationship is established by conducting isothermal CP tests at varying exposure times on 316 Ss at 1300 and 1500 F. A reduction in the CP cycle life is observed with an increase in the exposure time of the CP test at a given inelastic strain-range. This phenomenon is characterized by modifying the Manson-Coffin type of CP relationship. Two new life relationships: (1) the Steady State Creep Rate (SSRC) Modified CP life relationship, and (2) the Failure Time (FT) Modified CP life relationship, are developed in this report. They account for the effect of creep rate and exposure time within the CP type of waveform. The reduction in CP cyclic life in the long exposure time tests is attributed to oxidation and the precipitation of carbides along the grain boundaries.

Kalluri, S.↗

Cascade Distiller System Performance Testing Interim Results

The Cascade Distillation System (CDS) is a rotary distillation system with potential for greater reliability and lower energy costs than existing distillation systems. Based upon the results of the 2009 distillation comparison test (DCT) and recommendations of the expert panel, the Advanced Exploration Systems (AES) Water Recovery Project (WRP) project advanced the technology by increasing reliability of the system through redesign of bearing assemblies and improved rotor dynamics. In addition, the project improved the CDS power efficiency by optimizing the thermoelectric heat pump (TeHP) and heat exchanger design. Testing at the NASA-JSC Advanced Exploration System Water Laboratory (AES Water Lab) using a prototype Cascade Distillation Subsystem (CDS) wastewater processor (Honeywell d International, Torrance, Calif.) with test support equipment and control system developed by Johnson Space Center was performed to evaluate performance of the system with the upgrades as compared to previous system performance. The system was challenged with Solution 1 from the NASA Exploration Life Support (ELS) distillation comparison testing performed in 2009. Solution 1 consisted of a mixed stream containing human-generated urine and humidity condensate. A secondary objective of this testing is to evaluate the performance of the CDS as compared to the state of the art Distillation Assembly (DA) used in the ISS Urine Processor Assembly (UPA). This was done by challenging the system with ISS analog waste streams. This paper details the results of the AES WRP CDS performance testing.

Callahan, Michael R.↗

Initial development of a method for correlating indentation test results to damage accumulation in high temperature structural materials

This report describes an experimental approach based on microindentation creep or relaxation tests for assessing the remaining creep life of a sample material. The objective for this experimental program is to complement the development of passively loaded in situ surveillance specimens. These surveillance specimens could be placed in future advanced reactors to assess the degradation of structural properties, primary creep and creep-fatigue life, when the material is exposed to actual reactor operating conditions. The specimens and the corresponding indentation test protocol could form the basis of a structural health monitoring program designed to ensure the safe continued operation of the component given the relatively unknown effect of the reactor coolant chemistry, radiation exposure, and other environmental effects on the material properties of the constituent structural materials.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗