Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

An investigation of short period oscillations of the solar irradiance and their time variations

Measurements of solar irradiance fluctuations by the Active Cavity Radiometer (ACRIM) instrument onboard the Solar Maximum Mission (SMM) show variations on a time scale of about 5 minutes due to solar p-mode oscillations, as well as longer-term variations related to solar magnetic activity. The question was studied whether the p-mode frequencies change with time as a result of changing solar structure associated with the activity cycle. The ACRIM data on SMM are particularly well-suited for this purpose, because the instrument operated continuously from February 1980 to December 1980 and again from May 1984 to the present. The main activity entailed a detailed study of the observational data to determine if a change in the p-mode frequencies is evident from the time of solar maximum to that of solar minimum. It was concluded that the measured eigenfrequencies were significantly higher during the 1980 time frame than during the 1984 to 1986 time frame. The conclusion that there is significant change in the eigenfrequencies with the activity cycle remains only tentative, and needs confirmation from analysis of more data during the upcoming solar maximum.

Noyes, Robert W.↗

Design, development, and results from a charge-collector diagnostic for a toroidal electron plasma experiment

A suitable charge-collector has been designed and developed to estimate charge-content of electron plasmas in a Small Aspect Ratio Toroidal Experiment in a C-shaped trap (SMARTEX-C). The electrons are periodically injected and held in the trap with the aid of electrostatic end-fields and a toroidal magnetic field. After a preset “hold” time, the trapped charges are dumped onto a grounded collector (by gating it). As the charges flow along the magnetic field lines onto the collector, the integrated current gives the charge-content of the plasma at the instant of dump. In designing such a charge collector, several challenges peculiar to the geometry of the trap and the nature of the plasma had to be addressed. Instantaneous charge measurements synchronised with the E × B drift of the plasma, along with fast transit times of electrons to the collector (few 100 ns or less) (due to the low aspect ratio of the trap) essentially require fast gating of the collector. The resulting large capacitive transients alongside low charge content (few nC) of such plasmas further lead to increasing demands on response and sensitivity of the collector. Complete cancellation of such transients is shown to be possible, in principle, by including the return path in our measurement circuit but the “non-neutrality” of the plasma acts as a further impediment. Ultimately, appropriate shielding and measurement circuits allow us to (re)distribute the capacitance and delineate the paths of these currents, leading to effective cancellation of transients and marked improvement in sensitivity. Improved charge-collector has thus been used to successfully estimate the time evolution of total charge of the confined electron plasma in SMARTEX-C.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of the Heliospheric Radial Magnetic Field from the Standoff Distance of a CME-Driven Shock Observed by the Stereo Spacecraft

We report on the determination of radial magnetic field strength in the heliocentric distance range from 6 to 120 solar radii (R-solar) using data from Coronagraph 2 (COR2) and Heliospheric Imager I (HI1) instruments on board the Solar Terrestrial Relations Observatory spacecraft following the standoff-distance method of Gopalswamy & Yashiro. We measured the shock standoff distance of the 2008 April 5 coronal mass ejection (CME) and determined the flux-rope curvature by fitting the three-dimensional shape of the CME using the Graduated Cylindrical Shell model. The radial magnetic field strength is computed from the Alfven speed and the density of the ambient medium. We also compare the derived magnetic field strength with in situ measurements made by the Helios spacecraft, which measured the magnetic field at the heliocentric distance range from 60 to 215 R-solar.We found that the radial magnetic field strength decreases from 28 mG at 6 R-solar to 0.17 mG at 120 R-solar. In addition, we found that the radial profile can be described by a power law.

CMEs↗

Ion Accumulation Approaches for Increasing Sensitivity and Dynamic Range in the Analysis of Complex Samples

EXTERNAL ACCUMULATION OF IONS FOR FTICR DETECTION The need for higher mass accuracy and precision in analysis of e.g. biological compounds is now commonly addressed by storing charged particles in an ion trap using a superposition of the constant static magnetic and spatially inhomogeneous electric fields, often referred to as Penning trap. The Penning trap has been successfully employed in Fourier Transform Ion Cyclotron Resonance (FTICR) MS instrumentation. Since its inception in 1973,1 FTICR has been the subject of multiple reviews,2-9 several journal issues10,11 and books12,13 that give a full-range technical introduction to both single ion and more populated ion clouds (a group of ions who’s motion is to some extent influenced by the other ions in the cloud) behavior in combined magnetic and electric fields, subsequent signal processing, and technique applications. Principles and design of geometric and electrical configurations of ICR traps have been also reviewed.14 The reader is referred to these publications for more information. Herein, we will give a brief overview of the ion cloud behavior in the superimposed magnetic and electric fields, with an emphasis on ICR trap design, and highlight FTICR performance improvements due to accumulation of ions in another trap external to FTICR.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The MAGNEX large acceptance spectrometer

The main features of the MAGNEX large acceptance magnetic spectrometer are described. It has a quadrupole + dipole layout and a hybrid detector located at the focal plane. The aberrations due to the large angular (50 msr) and momentum (+- 13%) acceptance are reduced by an accurate hardware design and then compensated by an innovative software ray-reconstruction technique. The obtained resolution in energy, angle and mass are presented in the paper. MAGNEX has been used up to now for different experiments in nuclear physics and astrophysics confirming to be a multipurpose device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An electron/ion spectrometer with the ability of low energy electron measurement for fast ignition experiments

An electron energy spectrometer (ESM) is one of the most fundamental diagnostics in the fast ignition experiment. It is necessary to observe the spectra down to a low energy range in order to obtain the accurate deposition efficiency toward the core. Here, we realize the suitable ESM by using a ferrite magnet with a moderate magnetic field of 0.3 T and a rectangular magnetic circuit covered with a steel plate in the inlet side.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An interchangeable scanning Hall probe/scanning SQUID microscope

We have constructed a scanning probe microscope for magnetic imaging, which can function as a scanning Hall probe microscope (SHPM) and as a scanning SQUID microscope (SSM). The scanning scheme, applicable to SHPM and SSM, consists of a mechanical positioning (sub) micron-XY stage and a flexible direct contact to the sample without a feedback control system for the Z-axis. With the interchangeable capability of operating two distinct scanning modes, our microscope can incorporate the advantageous functionalities of the SHPM and SSM with large scan range up to millimeter, high spatial resolution (⩽4 μm), and high field sensitivity in a wide range of temperature (4.2 K-300 K) and magnetic field (10{sup −7} T-1 T). To demonstrate the capabilities of the system, we present magnetic images scanned with SHPM and SSM, including a RbFeB magnet and a nickel grid pattern at room temperature, surface magnetic domain structures of a La{sub 2/3}Ca{sub 1/3}MnO{sub 3} thin film at 77 K, and superconducting vortices in a striped niobium film at 4.2 K.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-screen single-shot electron spectrometer for laser wakefield accelerated electron beams

The laser wakefield acceleration electron beams can essentially deviate from the axis of the system, which distinguishes them greatly from beams of conventional accelerators. In case of energy measurements by means of a permanent-magnet electron spectrometer, the deviation angle can affect accuracy, especially for high energies. A two-screen single-shot electron spectrometer that correctly allows for variations of the angle of entry is considered. The spectrometer design enables enhancing accuracy of measuring narrow electron beams significantly as compared to a one-screen spectrometer with analogous magnetic field, size, and angular acceptance.

43 PARTICLE ACCELERATORS↗

DETERMINATION OF THE HELIOSPHERIC RADIAL MAGNETIC FIELD FROM THE STANDOFF DISTANCE OF A CME-DRIVEN SHOCK OBSERVED BY THE STEREO SPACECRAFT

We report on the determination of radial magnetic field strength in the heliocentric distance range from 6 to 120 solar radii (R {sub Sun }) using data from Coronagraph 2 (COR2) and Heliospheric Imager I (HI1) instruments on board the Solar Terrestrial Relations Observatory spacecraft following the standoff-distance method of Gopalswamy and Yashiro. We measured the shock standoff distance of the 2008 April 5 coronal mass ejection (CME) and determined the flux-rope curvature by fitting the three-dimensional shape of the CME using the Graduated Cylindrical Shell model. The radial magnetic field strength is computed from the Alfven speed and the density of the ambient medium. We also compare the derived magnetic field strength with in situ measurements made by the Helios spacecraft, which measured the magnetic field at the heliocentric distance range from 60 to 215 R {sub Sun }. We found that the radial magnetic field strength decreases from 28 mG at 6 R {sub Sun} to 0.17 mG at 120 R {sub Sun }. In addition, we found that the radial profile can be described by a power law.

79 ASTRONOMY AND ASTROPHYSICS↗

The application of wavelet shrinkage denoising to magnetic Barkhausen noise measurements

The application of Magnetic Barkhausen Noise (MBN) as a non-destructive method of defect detection has proliferated throughout the manufacturing community. Instrument technology and measurement methodology have matured commensurately as applications have moved from the R and D labs to the fully automated manufacturing environment. These new applications present a new set of challenges including a bevy of error sources. A significant obstacle in many industrial applications is a decrease in signal to noise ratio due to (i) environmental EMI and (II) compromises in sensor design for the purposes of automation. The stochastic nature of MBN presents a challenge to any method of noise reduction. An application of wavelet shrinkage denoising is proposed as a method of decreasing extraneous noise in MBN measurements. The method is tested and yields marked improvement on measurements subject to EMI, grounding noise, and even measurements in ideal conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Individual NSLS-II Multipole Magnet Alignment by Laser Trackers

The magnet alignment of the 90 th and final multipole girder assembly was completed January 17 th , 2013. Our procedure of “rough” pre-alignment by laser trackers and final alignment by vibrating wire & “Differential Variable Reluctance Transducers” (DVRT) has been quite successful, achieving magnet to magnet alignment well under the 30 micron specification. The pre-alignment accuracy is verified by the initial scan from the vibrating wire. The alignment residuals can be calculated from the offsets of a best fit line. The results are impressive, especially considering the environment of the Building 902 Annex (which has a large bay door that would open during pre-alignment, without fail), the sloppiness of the magnets’ fiducials, and especially the fact that the girders were pre-aligned to their mechanical centers, but the vibrating wire reports the magnetic centers which may be considerably different. This result hints at the potential feasibility of alignment with laser trackers for replacement magnets of NSLS-II and maybe even all magnets of future accelerators. But, it is difficult to predict the achievable accuracy until the main three error sources (a.k.a. Survey group excuses) are eliminated: measuring environment, bad magnet fiducials, and mechanical/magnetic center differences. The test performed on a large aperture quadrupole on girder assembly C19G4 was designed to answer the following questions with the aforementioned error sources either eliminated or simulated: 1) How accurately can a NSLS-II multipole be realigned after repair or other disturbance given the existing fiducials? 2) How accurately can a replacement NSLS-II multipole be installed in situ if its magnetic center is known relative to good fiducials? 3) If the current NSLS-II spares are never magnetically fiducialized, how well can they be installed using only mechanical data? 4) Could the magnets of a future accelerator (with similar alignment specifications as NSLS-II) be aligned using commercially available metrology instruments? This paper will answer these questions.

36 MATERIALS SCIENCE↗

Rocket-borne particle, field, and plasma observations in the cleft region

Results are reported for comprehensive observations of magnetic and electric fields together with ambient and suprathermal plasmas above the dayside auroral oval with rocket-borne instrumentation which penetrated the cleft region. Measurements were also obtained equatorward and poleward of the cleft. Convection velocities as inferred from electric-field measurements were generally toward noon equatorward of the cleft and were antisunward over the polar cap. Observations of electron temperatures, electric fields, and low-frequency electrostatic noise provide strong evidence of a plasma instability (Farley-Buneman) in the E-layer associated with the appearance of the 'slant E condition' identified in ground-acquired ionograms. The positions of these measurements relative to that of the cleft were firmly established via the determination of the plasma environment with an electrostatic analyzer.

Ungstrup, E.↗

The ISEE-C vector helium magnetometer

The ISEE-C magnetometer will make continuous observations of the interplanetary magnetic field near 1 AU. This paper describes the scientific objectives of the magnetometer experiment and gives attention to instrument design (sensor, electronics, and operating principles). A functional block diagram of the system is presented and attention is given to minor modifications required by the ISEE mission (the magnetometer is essentially one that served as the spare unit for the Pioneer 10 and 11 missions to Jupiter).

Frandsen, A. M. A.↗

The 3-dimensional radio mapping experiment /SBH/ on ISEE-C

The SBH experiment on ISEE-C will provide maps of the large scale structure of the interplanetary magnetic field from ten solar radii altitude to the earth orbit, in and out of the ecliptic. The SBH instrument will track type III solar radio bursts at 24 frequencies in the range 30 kHz-2 MHz thus providing the positions of 24 points along the line of force which guides the electrons producing the radio radiation. The antennas are two dipoles: one (90 m long) in the spin plane, the other (15 m long) along the spin axis. The receiver was designed for high sensitivity (0.3 microV in 3 kHz BW), high intermodulation rejection (80 dB/1 microV input for order 2 products), large dynamic range (70 dB), high selectivity (-30-dB response 6.5 kHz away from the center frequency of 10.7 MHz for the 3 kHz BW channels), and high reliability (expected orbital life: 3 years).

Knoll, R.↗

Bi-directional streaming of solar wind electrons greater than 80 eV - ISEE evidence for a closed-field structure within the driver gas of an interplanetary shock

In near time coincidence with the arrival of helium enriched plasma driving the shock wave disturbance of November 12-13, 1978, strong bi-directional streaming of solar wind electrons greater than about 80 eV was observed with Los Alamos instrumentation on ISEE 3. The streaming persisted for many hours simultaneously parallel and anti-parallel to the interplanetary magnetic field which was directed roughly perpendicular to the sun-satellite line. This example of bidirectional streaming cannot be explained by field line connection to the earth's bow shock or the outward propagating interplanetary shock which passed ISEE 3 approximately 16 hours earlier. The event is explained if the local interplanetary field was a part of a magnetic bottle rooted at the sun or a disconnected loop propagating outward.

Bame, S. J.↗

Characteristics of thermal and suprathermal ions associated with the dayside plasma trough as measured by the dynamics explorer retarding ion mass spectrometer

The thermal and suprathermal ion populations present in the refilling regions after a magnetic storm are examined using retarding ion mass spectrometer (RIMS) data from the Dynamics Explorer 1 spacecraft. The RIMS instrument is described, and data are presented and discussed in detail for the outer plasmasphere, plasmapause, depleted dayside magnetosphere, and dayside cusp. Three distinct populations were observed: thermal ions, warm anisotropic plasma, and the polar wind. The characteristics of these populations are considered, including the densities, temperatures, and density ratios. Aspects of the ionospheric plasma outflow are discussed, including the field-aligned flow speed, the ionospheric plasma escape flux, plasmaspheric refilling, and wave-particle phenomena.

Sojka, J. J.↗

Improved Flux-Gate Magnetometer

Simplified circuit drives heading indicator and senses magnetic field of Earth. Simple flux-gate magnetometer supplies digital readout of magnetic heading of vehicle, developed to drive heading indicator, or supply heading information to autopilot or to other navigational instruments. Important feature is core driven into saturation in one direction only by alternating drive voltage, which swings from zero to one polarity and back. Made in part of commercially available integrated circuits.

Garner, H. Douglas↗

In situ measurement of atomic hydrogen in the upper mesosphere

In situ measurements of H abundance between 73 and 93 km are reported for conditions of winter solstice, magnetic quiet, and a solar depression angle of 12 deg. The data were obtained by a rocket-borne instrument using the resonance fluorescence technique. A discharge source emitting photons at 1216 A was an integral part of the instrument. The instrument was radially deployed 80 cm by a boom from the front of the payload in order to avoid the shock created by the gas flow over the front of the payload. An attitude control system oriented the payload so that the gas flow was nearly perpendicular to the plane containing the incident and scattered photons, thus minimizing any correction for Doppler shift. The resonance radiation detector viewed a black backstop in order to minimize background radiation from the hydrogen geocorona; however, the background was not entirely eliminated. The signal-to-noise ratio was improved by summing the data in 1.8-s bins. The observed hydrogen concentration maximized at 85 km at 1.5 + or - 1.1 x 10 to the 8th atoms/cu cm.

Sharp, W. E.↗