Modeling of Thermal Decomposition of TATB-Based Explosive for Safety Analysis
We investigate and model the cook-off behavior of LX-17 to understand the response of explosive systems in abnormal thermal environments. Decomposition has been explored via conventional ODTX (One-Dimensional Time-to-eXplosion), PODTX (ODTX with pressure-measurement), TGA (Thermo-Gravimetric Analysis), and DSC (Differential Scanning Calorimetry) experiments under isothermal and ramped temperature profiles. The data were used to fit reaction rate parameters for proposed schemes in an ALE3D computational model. This model includes chemical reactions, thermo- and hydro-dynamics, and material properties, including thermal expansion, compressibility, and strength. These parameterizations were carried out utilizing a Python evolutionary optimization method on LLNL’s high-performance computing clusters. Additional experiments are being developed to further characterize and monitor decomposition intermediates to improve the model. Once experimentally validated, this model will be scalable to several applications involving LX-17. Furthermore, the optimization methodology developed herein should be applicable to other high explosive materials.
Thermal Stress Modeling and Analysis of Packed-bed Thermocline Energy Storage Tank for INL Thermal Energy Distribution System (TEDS)
The Thermal Energy Distribution System (TEDS) at Idaho National Laboratory (INL) is a thermal-hydraulic flow loop to support the integration of co-located multiple experimental systems, where a packed-bed thermal energy storage (TES) is installed as a thermal buffer and storage unit for TEDS. The packed-bed TES is adopted in TEDS because of its benefit as a low-cost single-tank storage option compared to the traditional two-tank storage. However, thermal ratcheting is one potential design concern which is caused by the rearrangement of granular filler inside a packed-bed tank during continuous thermal cycling operation of the packed-bed TES tank. If the thermally induced stress exceeds yield strength of the tank wall, it may cause catastrophic consequences like rupture of the thermal storage tank. Thus, it is crucial to understand the phenomenon to ensure the robust operation. Based on the temperature boundary conditions given by transient thermal analyses with computational fluid dynamics (CFD) simulations, the thermal ratcheting analysis is then conducted to evaluate the hoop stress and resultant thermal ratcheting potential of the TES tanks with two different modeling approaches: (1) infinite rigidity model and (2) Drucker-Prager (DP) model. The validity of each modeling method was examined by comparing the numerical simulation with the experimental data obtained from the packed-bed TES tank for Solar One Plant and evaluate the thermal ratcheting potential of the TEDS TES tank.
Design, Modeling, and Experimental Validation for life-optimization of Hydrogen Turbine CMC Components
Explore the source record for details and available documents.
LANSCE BEAM TRANSPORT MODEL ENHANCEMENT AND VALIDATION
Explore the source record for details and available documents.
Validation of CTF Models Using NRC Data from RBHT Reflood Experiments
Explore the source record for details and available documents.
The FastEddy® Resident-GPU Accelerated Large-Eddy Simulation Framework: Moist Dynamics Extension, Validation and Sensitivities of Modeling Non-Precipitating Shallow Cumulus Clouds
Herein we describe the moist dynamics formulation implemented within the graphics processing unit-resident large-eddy simulation FastEddy® model, which includes a simple saturation adjustment scheme for condensation and evaporation processes. Two LES model intercomparison exercises for non-precipitating shallow cumulus clouds are simulated in order to validate this model extension, including a static forcing and a time-dependent forcing case. Overall, we find our dynamical, thermodynamical and microphysical quantities, along with turbulence variability and fluxes, to be commensurate with the corresponding model intercomparison results. In addition, sensitivities to specific model settings are investigated. Among these settings, it is shown that boundary layer and cloud layer structure and characteristics are sensitive to use of higher-order advection schemes impacting the vertical distribution of cloud content and associated turbulence statistics. Increasing the timescale of the saturation scheme leads to enhanced liquid water presence and decreases vertical velocity variance within the cloud deck. In some cases, these sensitivities agree with the model-to-model variability reported in the intercomparison exercises, highlighting the important role of specific model implementation choices in the context of shallow cumulus convection simulations. These analyses and findings also provide the basis for future extensions and applications of FastEddy® for modeling moist convection and precipitation scenarios.
Computational Fluid Dynamics Modeling of Bubbling in a Viscous Fluid for Validation of Waste Glass Melter Modeling
At the Hanford site, radioactive waste stored in underground tanks is slated for vitrification for final disposal. A comprehensive knowledge of the glass batch melting process will be useful in optimizing the process, which could potentially reduce the cost and duration of this multi-billion dollar cleanup effort. We are developing a high-fidelity heat transfer model of a Joule-heated ceramic lined melter to improve the understanding of the complex, inter-related processes occurring with the melter. The glass conversion rates in the cold cap layer are dependent on promoting efficient heat transfer. In practice, heat transfer is augmented by inserting air bubblers into the molten glass. However, the computational simulations must be validated to provide confidence in the solutions. As part of a larger validation procedure, it is beneficial to split the physics of the melter into smaller systems to validate individually. The substitution of molten glass for a simulant liquid with similar density and viscosity at room temperature provides a way to study mixing through bubbling as an isolated effect without considering the heat transfer dynamics. The simulation results are compared to experimental data obtained by the Vitreous State Laboratory at the Catholic University of America using bubblers placed within a large acrylic tank that is similar in scale to a pilot glass waste melter. Comparisons are made for surface area of the rising air bubbles between experiments and CFD simulations for a variety of air flow rates and bubble injection depths. Also, computed bubble rise velocity is compared to a well-accepted expression for bubble terminal velocity.
Computational Fluid Dynamics Modeling of Bubbling in a Viscous Fluid for Validation of Waste Glass Melter Modeling
At the Hanford site, radioactive waste stored in underground tanks is slated for vitrification for final disposal. A comprehensive knowledge of the glass batch melting process will be useful in optimizing the process, which could potentially reduce the cost and duration of this multi-billion dollar cleanup effort. We are developing a high-fidelity heat transfer model of a Joule-heated ceramic lined melter to improve the understanding of the complex, inter-related processes occurring with the melter. The glass conversion rates in the cold cap layer are dependent on promoting efficient heat transfer. In practice, heat transfer is augmented by inserting air bubblers into the molten glass. However, the computational simulations must be validated to provide confidence in the solutions. As part of a larger validation procedure, it is beneficial to split the physics of the melter into smaller systems to validate individually. The substitution of molten glass for a simulant liquid with similar density and viscosity at room temperature provides a way to study mixing through bubbling as an isolated effect without considering the heat transfer dynamics. The simulation results are compared to experimental data obtained by the Vitreous State Laboratory at the Catholic University of America using bubblers placed within a large acrylic tank that is similar in scale to a pilot glass waste melter. Comparisons are made for surface area of the rising air bubbles between experiments and CFD simulations for a variety of air flow rates and bubble injection depths. Also, computed bubble rise velocity is compared to a well-accepted expression for bubble terminal velocity (authors)
Optimization of Marine Energy Conversion Systems Through Modeling, Optimization, and CHIL Validation
The work aims to achieve optimal tidal energy conversion through a comprehensive approach of modeling, optimization, and control hardware-in-the-loop (CHIL) validation. By developing accurate models and employing optimization techniques, it seeks to identify efficient system configurations and control strategies. HIL validation will ensure the performance and reliability of the optimized tidal energy conversion system. The preparation of the present manual has been supported by the U.S. Department of Energy.
The Corrected Distortion model for Lagrangian spray simulation of transcritical fuel injection
In this work, we present a detailed implementation and validation of the droplet modeling framework proposed by Dahms and Oefelein (2016) into the engine commercial CFD software CONVERGE using the User Defined Function (UDF) interface. The model accounts for the nonlinear deformation and oscillation experienced by liquid spray droplet injected into high pressure and temperature. Lagrangian spray simulations of Engine Combustion Network (ECN) Spray A are performed. Model validation against standard experimental measurements of liquid velocity, vapor mixture fraction is conducted. To perform more rigorous model validation, new experimental measurements based on Diffused Back Illumination (DBI) are introduced. The new measurements are processed for Projected Liquid Volume (PLV), which offers as close as possible one-to-one model validation for liquid penetration while offering new insights into the spray physics. Comparison with a One-D model based on adiabatic mixing theory by Siebers (1999) and Desantes et al. (2007) are also conducted. Through these model validation exercises, it is shown that the new framework improves liquid-phase penetration predictions, following a tendency for enhanced evaporation, compared to the standard approach for both Reynolds Average Navier Stokes (RANS) and Large Eddy Simulation (LES). Additionally, at the liquid length, maximum mixture fraction values predicted by the new approach are in good agreement those of an adiabatic mixing model. Qualitative analysis of the spray behaviors during the early stage of the injection process reveals that the proposed framework predicts significant increase in droplet evaporation rate with lower drop drag compared to the current standard approach.
Experimental and Simulation Analysis of Binary Mixtures of Biomass and Inert Material
A literature review was conducted to identify experiments on various scales of biomass combustion specific to circulating fluidized bed (CFB) combustors. Typical feedstock and inert bed material characteristics for biomass combustion in a CFB were gathered. This information was used to design laboratory-scale, non-reacting experiments on biomass-inert bed material mixtures in a 1-in. cylindrical test rig in the Multiphase Flow Analysis Laboratory (MFAL) in Morgantown, WV. The biomass chosen was a hardwood. Pellets from the hardwood were milled and sieved to obtain three size ranges—small, medium, and large. Three mass loadings of each of the biomass samples were fluidized with glass beads as the inert bed material to study the mixing characteristics under varying fluidizing gas velocities. Hydrodynamic data including pressure drop measurements at select vertical locations and video recordings of the mixture behavior were generated in this effort.
Validation of Geant4 physics models using collision data from the LHC
CMS experiment has designed a strategy to validate GEANT4 physics models using collision data from the Large Hadron Collider. Isolated charged particles are measured simultaneously in the tracker as well as in the calorimeters. These events are selected using dedicated triggers and are used to measure the response in the calorimeter. Measurements of mean response, resolution, energy sharing between the electromagnetic and hadron calorimeters, shower shapes are directly compared with predictions from the Monte Carlo. Single particle response is also used in calibrating the calorimeters and in improving jet energy measurements. GEANT4 physics models are also used to understand the source of anomalous high energy deposits in the calorimeter.
Validation of a FAST model of the Statoil-Hywind Demo floating wind turbine
To assess the accuracy of the National Renewable Energy Laboratory's (NREL's) FAST simulation tool for modeling the coupled response of floating offshore wind turbines under realistic open-ocean conditions, NREL developed a FAST model of the Statoil Hywind Demo floating offshore wind turbine, and validated simulation results against field measurements. Field data were provided by Statoil, which conducted a comprehensive test measurement campaign of its demonstration system, a 2.3-MW Siemens turbine mounted on a spar substructure deployed about 10 km off the island of Karmoy in Norway. A top-down approach was used to develop the FAST model, starting with modeling the blades and working down to the mooring system. Design data provided by Siemens and Statoil were used to specify the structural, aerodynamic, and dynamic properties. Measured wind speeds and wave spectra were used to develop the wind and wave conditions used in the model. The overall system performance and behavior were validated for eight sets of field measurements that span a wide range of operating conditions. The simulated controller response accurately reproduced the measured blade pitch and power. In conclusion, the structural and blade loads and spectra of platform motion agree well with the measured data.
RADIOGRAPHIC BENCHMARK PROBLEM 2009 - SCATTER CALCULATIONS IN MODELLING
Code Validation is a permanent concern in computer simulation, and has been addressed repeatedly in eddy current and ultrasonic modelling. A good benchmark problem is sufficiently simple to be taken into account by various codes without strong requirements on geometry representation capabilities, focuses on few or even a single aspect of the problem at hand to facilitate interpretation and to avoid that compound errors compensate themselves, yields a quantitative result and is experimentally accessible. In this paper we attempt to address code validation for one aspect of radio-graphic modelling, the scattered radiation prediction. An update of the results of the 2008 benchmark is presented. Additionally we discuss the extension of this benchmark on the lower energy part for 60 and 80 keV as well as for higher energies up to 10 MeV to study the contribution of pair production. Of special interest will be the primary radiation (attenuation law as reference), the total scattered radiation, the relative contribution of scattered radiation separated by order of scatter events (1st, 2nd, ..., 20th), and the spectrum of scattered radiation. We present the results of three Monte Carlo codes (MC-Ray, Sindbad and Moderato) as well as an analytical first order scattering code (VXI) and compare to MCNP as reference.
Development and Validation of a Prognostic Model Using Blood Biomarker Information for Prediction of Survival of Non-Small-Cell Lung Cancer Patients Treated With Combined Chemotherapy and Radiation or Radiotherapy Alone (NCT00181519, NCT00573040, and NCT00572325)
Purpose: Currently, prediction of survival for non-small-cell lung cancer patients treated with (chemo)radiotherapy is mainly based on clinical factors. The hypothesis of this prospective study was that blood biomarkers related to hypoxia, inflammation, and tumor load would have an added prognostic value for predicting survival. Methods and Materials: Clinical data and blood samples were collected prospectively (NCT00181519, NCT00573040, and NCT00572325) from 106 inoperable non-small-cell lung cancer patients (Stages I-IIIB), treated with curative intent with radiotherapy alone or combined with chemotherapy. Blood biomarkers, including lactate dehydrogenase, C-reactive protein, osteopontin, carbonic anhydrase IX, interleukin (IL) 6, IL-8, carcinoembryonic antigen (CEA), and cytokeratin fragment 21-1, were measured. A multivariate model, built on a large patient population (N = 322) and externally validated, was used as a baseline model. An extended model was created by selecting additional biomarkers. The model's performance was expressed as the area under the curve (AUC) of the receiver operating characteristic and assessed by use of leave-one-out cross validation as well as a validation cohort (n = 52). Results: The baseline model consisted of gender, World Health Organization performance status, forced expiratory volume, number of positive lymph node stations, and gross tumor volume and yielded an AUC of 0.72. The extended model included two additional blood biomarkers (CEA and IL-6) and resulted in a leave-one-out AUC of 0.81. The performance of the extended model was significantly better than the clinical model (p = 0.004). The AUC on the validation cohort was 0.66 and 0.76, respectively. Conclusions: The performance of the prognostic model for survival improved markedly by adding two blood biomarkers: CEA and IL-6.
CGMF & FREYA Verification in MCNP6
At the present time, the new and updated fission event generators included in MCNP6.2 have been verified to be functioning properly through a variety of detailed tests. This work describes the detailed verification steps taken to ensure these complicated fission event generators, FREYA and CGMF, are integrated into MCNP6 properly. Ultimately, with the knowledge that MCNP6 is making use of these models appropriately, we can now begin to validate the models against benchmarked experiments. Some benchmarks, including criticality and subcritical experiments interested in multiplication and bulk counting rates, are easy to model and understand but are likely insensitive to the detailed nature of these models. It will take some new measurements with coincidence detection capabilities to be able to stress the physics within each of these fission event generator models. Once the models are validated and it is understood where the models can truly be predictive, then we can study what SNM observables can be characterized for nonproliferation applications.
Applicability Analysis of Validation Evidence for Biomedical Computational Models
Computational modeling has the potential to revolutionize medicine the way it transformed engineering. However, despite decades of work, there has only been limited progress to successfully translate modeling research to patient care. One major difficulty which often occurs with biomedical computational models is an inability to perform validation in a setting that closely resembles how the model will be used. For example, for a biomedical model that makes in vivo clinically relevant predictions, direct validation of predictions may be impossible for ethical, technological, or financial reasons. Unavoidable limitations inherent to the validation process lead to challenges in evaluating the credibility of biomedical model predictions. Therefore, when evaluating biomedical models, it is critical to rigorously assess applicability, that is, the relevance of the computational model, and its validation evidence to the proposed context of use (COU). However, there are no well-established methods for assessing applicability. In this paper, we present a novel framework for performing applicability analysis and demonstrate its use with a medical device computational model. The framework provides a systematic, step-by-step method for breaking down the broad question of applicability into a series of focused questions, which may be addressed using supporting evidence and subject matter expertise. The framework can be used for model justification, model assessment, and validation planning. While motivated by biomedical models, it is relevant to a broad range of disciplines and underlying physics. Finally, the proposed applicability framework could help overcome some of the barriers inherent to validation of, and aid clinical implementation of, biomedical models.