Search NASA⌕ Search

SEARCH · Search NASA

Results for “Modulator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

SU-E-T-325: The New Evaluation Method of the VMAT Plan Delivery Using Varian DynaLog Files and Modulation Complexity Score (MCS)

Purpose: The aim of the study is to evaluate the use of Varian DynaLog files to verify VMAT plans delivery and modulation complexity score (MCS) of VMAT. Methods: Delivery accuracy of machine performance was quantified by multileaf collimator (MLC) position errors, gantry angle errors and fluence delivery accuracy for volumetric modulated arc therapy (VMAT). The relationship between machine performance and plan complexity were also investigated using the modulation complexity score (MCS). Plan and Actual MLC positions, gantry angles and delivered fraction of monitor units were extracted from Varian DynaLog files. These factors were taken from the record and verify system of MLC control file. Planned and delivered beam data were compared to determine leaf position errors and gantry angle errors. Analysis was also performed on planned and actual fluence maps reconstructed from those of the DynaLog files. This analysis was performed for all treatment fractions of 5 prostate VMAT plans. The analysis of DynaLog files have been carried out by in-house programming in Visual C++. Results: The root mean square of leaf position and gantry angle errors were about 0.12 and 0.15, respectively. The Gamma of planned and actual fluence maps at 3%/3 mm criterion was about 99.21. The gamma of the leaf position errors were not directly related to plan complexity as determined by the MCS. Therefore, the gamma of the gantry angle errors were directly related to plan complexity as determined by the MCS. Conclusion: This study shows Varian dynalog files for VMAT plan can be diagnosed delivery errors not possible with phantom based quality assurance. Furthermore, the MCS of VMAT plan can evaluate delivery accuracy for patients receiving of VMAT. Machine performance was found to be directly related to plan complexity but this is not the dominant determinant of delivery accuracy.

60 APPLIED LIFE SCIENCES↗

SU-E-T-440: Elliptical Source Model for IMRT and VMAT with Complex Modulation

Purpose: To improve dose calculation accuracy for highly modulated fields in IMRT and VMAT using an elliptical source model. Methods: For 2 TrueBeam linacs equipped with Millennium and HD MLCs, the source model of 6 and 15 MV beams was optimized with adjustments of the focal spot dimensions in the Varian Eclipse TPS. Starting from the measured focal spot size of 1.75 × 1.75 mm, the y-dimension of the source was varied while the x-dimension was kept constant. In addition, all other modeling parameters such as the extrafocal source and dosimetric leaf gap remained unchanged. The different models were compared with measured penumbra for jaws and MLC using ion chamber and diode. For 2 IMRT and 2 VMAT cases, the calculated doses were compared with radiochromic film and EPID measurements. Results: A source size of 1.75 × 0.75 mm was found to be optimal for beam modeling. The calculated penumbra (80–20) of a MLCdefined open field was within 0.8 mm compare to measurement for both the inline and crossline profile for various field sizes and depths. The dose gradients in the direction perpendicular to the MLC travel direction was better modeled compared to the source model with a circular focal spot of 1.75 mm for the fields with rigorous MLC modulation. Local differences up to 8% were found in those regions. Conclusion: The conventional source model using a symmetric focal spot tends to overestimate the penumbra perpendicular to the MLC travel direction, resulting in an inaccurate dose calculation especially for fields with complex MLC modulation. This can be improved with an elliptical source model and it can be considered as a standard as IMRT and VMAT treatments are becoming a norm for the clinic.

60 APPLIED LIFE SCIENCES↗

SU-E-P-15: Technique Factor Modulation and Reference Plane Air Kerma Rates in Response to Simulated Patient Thickness Variations for a Sample of Current Generation Fluoroscopes

Purpose: To evaluate and compare approaches to technique factor modulation and air kerma rates in response to simulated patient thickness variations for four state-of-the-art and one previous-generation interventional fluoroscopes. Methods: A polymethyl methacrylate (PMMA) phantom was used as a tissue surrogate for the purposes of determining fluoroscopic reference plane air kerma rates, kVp, mA, and spectral filtration over a wide range of simulated tissue thicknesses. Data were acquired for each fluoroscopic and acquisition dose curve within a default abdomen or body imaging protocol. Results: The data obtained indicated vendor- and model-specific variations in the approach to technique factor modulation and reference plane air kerma rates across a range of tissue thicknesses. Some vendors have made hardware advances increasing the radiation output capabilities of their fluoroscopes; this was evident in the acquisition air kerma rates. However, in the imaging protocol evaluated, all of the state-of-the-art systems had relatively low air kerma rates in the fluoroscopic low-dose imaging mode as compared to the previous-generation unit. Each of the newest-generation systems also employ copper filtration in the selected protocol in the acquisition mode of imaging; this is a substantial benefit, reducing the skin entrance dose to the patient in the highest dose-rate mode of fluoroscope operation. Conclusion: Understanding how fluoroscopic technique factors are modulated provides insight into the vendor-specific image acquisition approach and provides opportunities to optimize the imaging protocols for clinical practice. The enhanced radiation output capabilities of some of the fluoroscopes may, under specific conditions, may be beneficial; however, these higher output capabilities also have the potential to lead to unnecessarily high dose rates. Therefore, all parties involved in imaging, including the clinical team, medical physicists, and imaging vendors, must work together to ensure that adequate but not excessive radiation doses are used.

60 APPLIED LIFE SCIENCES↗

SU-E-T-08: A Beam Source Model for Monte Carlo Simulations of a Double-Scattering Proton Beam Delivery System Using Beam Current Modulation

Purpose: To reconstruct phase-space information upstream of patient specific collimators for Monte Carlo simulations using only radiotherapy planning system data. Methods: The proton energies are calculated based on residual ranges, e.g., sum of prescribed ranges in a patient and SSD. The Kapchinskij and Vladimirskij (KV) distribution was applied to sample proton’s x-y positions and momentum direction and the beam shape was assumed to be a circle. Free parameters, e.g., the initial energy spread and the emittance of KV distribution were estimated from the benchmarking with commissioning data in a commercial treatment planning system for an operational proton therapy center. The number of histories, which defines the height of individual pristine Bragg peaks (BP) of Spread-out Bragg peak (SOBP), are weighted based on beam current modulation and a correction factor is applied to take into account the fluence reduction as the residual range decreases due to the rotation of the range modulator wheel. The timedependent behaviors, e.g., the changes of the residual range and histories per a pristine BP, are realized by utilizing TOPAS (Tool for Particle Simulation). Results: Benchmarking simulations for selected SOBPs ranging 7.5 cm to 15.5 cm matched within 2 mm in range and up to 5 mm in SOBP width against measurement data in water phantom. We found this model tends to underestimate entrance dose by about 5 % in comparison to measurement. This was attributed to the situation that the energy distribution used in the model was limited in its granularity at the limit of single energy spectrum for the narrow angle modulator steps used in the proximal pull back region of the SOBPs. Conclusion: Within these limitations the source modeling method proved itself an acceptable alternative of a full treatment head simulation when the machine geometry and materials information are not available.

60 APPLIED LIFE SCIENCES↗

SU-E-T-787: Utility of the Two Candidate 192-Ir and 169-Yb HDR Sources for Use with a Novel Direction Modulated Brachytherapy Tandem Applicator for Cervical Cancer Treatment

Purpose: A novel tungsten alloy shielded, MRI-compatible, direction modulated brachytherapy (DMBT) concept tandem applicator, which enables unprecedented intensity modulation, was used to evaluate treatment plan quality improvement over a conventional tandem. The utility of the 192-Ir and 169-Yb HDR sources, for use with the DMBT applicator, was evaluated. Methods: The total diameter of the DMBT tandem applicator is 6.0 mm, which consists of 5.4-mm diameter tungsten alloy and 0.3 mm thick plastic sheath. The tandem has 6 symmetric peripheral 1.3-mm diameter grooves for the source to travel. MCNPX v.2.6 was used to simulate the 192-Ir and 169-Yb sources inside the DMBT applicator. First, TG-43 source parameters were evaluated. Second, 3D dose matrix with 1 mm3 resolution were imported into an in-house-coded inverse optimization treatment planning program to obtain optimal plans for 19 clinical cases. All plans were compared with the standard tandem and ring plans. Prescription dose was 15.0 Gy. All plans were normalized to receive the same HRCTV D90. Results: Generally, the DMBT tandem (and ring) plans were better than the conventional tandem and ring plans for 192-Ir and 169-Yb HDR sources. The mean data of D2cc for bladder, rectum, and sigmoid were 11.65±2.30 Gy, 7.47±3.05 Gy, and 9.84±2.48 Gy for Ir-192 DMBT tandem, respectively. These data for Yb-169 were 11.67±2.26 Gy, 7.44±3.02 Gy, and 9.83±2.38 Gy, respectively. The HR-CTV D98 and V100 were 16.37±1.86 Gy and 97.37 ± 1.92 Gy for Ir-192 DMBT, respectively. The corresponding values for Yb-169 were 16.43±1.86 Gy, and 97.51 ± 1.91 Gy. Plans with the 169-Yb source generally produced more favorable results where V100 increased by 13.65% while D2cc across all OARs reduced by 0.54% compared with the 192-Ir plans. Conclusion: For the DMBT tandem applicator, 169-Yb source seems to produce more directional beams resulting in increased intensity modulation capacity, thus resulting in more conformal plans.

60 APPLIED LIFE SCIENCES↗

SU-F-BRA-05: Utility of the Combined Use of Two Types of HDR Sources with the Direction Modulation Brachytherapy (DMBT) Tandem Applicator for Cervical Cancer Treatment

Purpose: To maximize the dose to HRCTV while minimizing dose to the OARs, the combination of two HDR brachytherapy sources, 192-Ir and 169-Yb, used in combination with the recently-proposed novel direction modulated brachytherapy (DMBT) tandem applicator were examined. Methods: The DMBT tandem, made from nonmagnetic tungsten-alloy rod, with diameter of 5.4mm, has 6 symmetric peripheral holes of 1.3mm diameter. The 0.3mm thick bio-compatible plastic tubing wraps the tandem. MCNPX v.2.6 was used to simulate the mHDR 192-Ir V2 and 4140 HDR 169-Yb sources inside the DMBT applicator. Thought was by combining the higher energy 192-Ir (380keV) and lower energy 169-Yb (92.7keV) sources could create unprecedented level of dose conformality when combined with the high-degree intensity modulation capable DMBT tandem applicator. 3D dose matrices, with 1 mm3 resolution, were imported into an in-house-coded inverse optimization planning system to evaluate plan quality of 19 clinical patient cases. Prescription dose was 15Gy. All plans were normalized to receive the same HRCTV D90. Results: Generally, the use of dual sources produced better plans than using either of the sources alone, with significantly better performance in some patients. The mean D2cc for bladder, rectum, and sigmoid were 11.65±2.30Gy, 7.47±3.05Gy, and 9.84±2.48Gy for 192-Ir-only, respectively. For 169 -Yb-only, they were 11.67±2.26Gy, 7.44±3.02Gy, and 9.83±2.38Gy, respectively. The corresponding data for the dual sources were 11.51±2.24Gy, 7.30±3.00Gy, and 9.68 ±2.39Gy, respectively. The HRCTV D98 and V100 were 16.37±1.86Gy and 97.37±1.92Gy for Ir-192-only, respectively. For 169-Yb-only, they were 16.43±1.86Gy, and 97.51±1.91Gy, respectively. For the dual source, they were 16.42±1.87Gy and 97.47±1.93Gy, respectively. Conclusion: The plan quality improves, in some cases quite significantly, for when dual 192-Ir and 169-Yb sources are used in combination with highly intensity modulation capable DMBT tandem applicator for image guided cervical cancer brachytherapy.

60 APPLIED LIFE SCIENCES↗

TU-EF-204-07: Add Tube Current Modulation to a Low Dose Simulation Tool for CT Systems

Purpose: We extended the capabilities of a low dose simulation tool to model Tube-Current Modulation (TCM). TCM is widely used in clinical practice to reduce radiation dose in CT scans. We expect the tool to be valuable for various clinical applications (e.g., optimize protocols, compare reconstruction techniques and evaluate TCM methods). Methods: The tube current is input as a function of z location, instead of a fixed value. Starting from the line integrals of a scan, a new Poisson noise realization at a lower dose is generated for each view. To validate the new functionality, we compared simulated scans with real scans in image space. Results: First we assessed noise in the difference between the low-dose simulations and the original high-dose scan. When the simulated tube current is a step function of z location, the noise at each segment matches the noise of 3 separate constant-tube-current-simulations. Secondly, with a phantom that forces TCM, we compared a low-dose simulation with an equivalent real low-dose scan. The mean CT number of the simulated scan and the real low-dose scan were 137.7±0.6 and 137.8±0.5 respectively. Furthermore, with 240 ROIs, the noise of the simulated scan and the real low-dose scan were 24.03±0.45 and 23.99±0.43 respectively, and they were not statistically different (2-sample t-test, p-value=0.28). The facts that the noise reflected the trend of the TCM curve, and that the absolute noise measurements were not statistically different validated the TCM function. Conclusion: We successfully added tube-current modulation functionality in an existing low dose simulation tool. We demonstrated that the noise reflected an input tube-current modulation curve. In addition, we verified that the noise and mean CT number of our simulation agreed with a real low dose scan. The authors are all employees of Philips. Yijun Ding is also supported by NIBIB P41EB002035 and NIBIB R01EB000803.

60 APPLIED LIFE SCIENCES↗

SU-F-J-39: Dose Reduction Strategy Using Attenuation-Based Tube Current Modulation Method in CBCT for IGRT

Purpose: To reduce radiation dose to the patients, tube current modulation (TCM) method has been actively used in diagnostic CT systems. However, TCM method has not yet been applied to a kV-CBCT system on a LINAC machine. The purpose of this study is to investigate whether the use of TCM method is desirable in kV-CBCT system for IGRT. We have developed an attenuation-based tube current modulation (a-TCM) method using the prior knowledge of treatment CT image of a patient. Methods: Patients go through a diagnostic CT scan for RT planning; therefore, using this prior information of CT images, one can estimate the total attenuation of an x-ray through the patient body in a CBCT setting for radiation therapy. We performed a numerical study incorporating major factors into account such as polychromatic x-ray, scatter, noise, and bow-tie filter to demonstrate that a-TCM method can produce equivalent quality of images at reduced imaging radiation doses. Using the CT projector program, 680 projection images of the pediatric XCAT phantom were obtained both in conventional scanning condition, i.e., without modulating the tube current, and in the proposed a-TCM scanning condition. FDK reconstruction algorithm was used for image reconstruction, and the organ dose due to imaging radiation has been calculated in both cases and compared using GATE/Geant4 simulation toolkit. Results: Reconstructed CT images in the a-TCM method showed similar SSIM values and noise properties to the reference images acquired by the conventional CBCT. In addition, reduction of organ doses ranged from 12% to 27%. Conclusion: We have successfully demonstrated the feasibility and dosimetric merit of the a-TCM method for kV-CBCT, and envision that it can be a useful option of CBCT scanning that provides patient dose reduction without degrading image quality.

60 APPLIED LIFE SCIENCES↗

Seasonal modulations of the underground cosmic-ray muon energy

The parameters of the seasonal modulations in the intensity of muons and cosmogenic neutrons generated by them at a mean muon energy of 280 GeV have been determined in the LVD (Large Volume Detector) experiment. The modulations of muons and neutrons are caused by a temperature effect, the seasonal temperature and density variations of the upper atmospheric layers. The analysis performed here leads to the conclusion that the variations in the mean energy of the muon flux are the main source of underground cosmogenic neutron variations, because the energy of muons is more sensitive to the temperature effect than their intensity. The parameters of the seasonal modulations in the mean energy of muons and the flux of cosmogenic neutrons at the LVD depth have been determined from the data obtained over seven years of LVD operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modulational instabilities in relativistic pair plasmas

We study the modulational instability of an intense photon beam in a relativistic pair plasma. We use the wave-kinetic description of the photon field and relativistic fluid equations for electrons and positrons. This allows us to consider the influence of the photon spectral distribution and photon recoil effects on the instability threshold and growth rates. The case of very low frequencies modulations, well below plasma frequency, is compared to that of high-frequency modulations corresponding to the plasmon decay instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Formation of ncl-Si in the Amorphous Matrix a-SiO{sub x}:H Located near the Anode and on the Cathode, Using a Time-Modulated DC Plasma with the (SiH{sub 4}–Ar–O{sub 2}) Gas Phase (C{sub O{sub 2}} = 21.5 mol %)

The formation of ncl-Si in the amorphous matrix a-SiO{sub x}:H using a time-modulated DC plasma at an elevated oxygen content of C{sub O{sub 2}} = 21.5 mol % in a gas mixture of (SiH{sub 4}–Ar–O{sub 2}) is investigated. Plasma modulation implies the repeated (n = 180) switching on (for t{sub on} = 5, 10, 15 s) and switching off (for t{sub off} = 5, 10, 15 s) of the magnet coil of the DC magnetron. The effect of self-induction is used to enhance the processes of SiH{sub 4} dissociation, the formation of Si nanoparticles, and the ionization of oxygen and ncl-Si flows towards the electrodes. The samples are located both on an electrically isolated substrate holder near the anode and on the cathode (beyond its erosion zone). These experiments show that the shape of the dependences of the photoluminescence intensity I{sub PL}{sup ncl−Si} on the wavelength Λ are identical for all pairs of samples on the anode and cathode. When the t{sub on} value is small (t{sub on} = 5 s), the difference in the sample location only slightly affects the infrared (IR) spectra. At longer times t{sub on} (≥10 s) and a short time t{sub off} (5 s), the amorphous matrix located on the cathode is enriched with oxygen (as compared with that near the anode). The optimal plasma-modulation parameters are found to be t{sub off}/t{sub on} = 5, 10, 15/10 and t{sub off}/t{sub on} = 5, 10/15; under these conditions, the amorphous matrix has a “perfect structure” and is transparent to radiation, and the I{sub PL}{sup ncl−Si} value is the largest in the range λ ≈ 0.75–0.9 μm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Acoustic vibrations in integrated electro-optic modulators on substrates of lithium niobate

The processes of the excitation of acoustic vibrations and their influence on the optical signals in integrated electro-optic modulators on substrates of lithium niobate have been investigated. The resonant frequencies of the excitation of substrate vibrational modes have been determined. It has been shown that acoustic vibrations can make a significant contribution to the modulator transfer characteristic at frequencies up to several hundred megahertz, which should be taken into account when using the modulators at low frequencies, for example, as a part of fiber-optic sensors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electrochemically modulated single-molecule localization microscopy for in vitro imaging cytoskeletal protein structures

A new concept of electrochemically modulated single-molecule localization super-resolution imaging is developed. Applications of single-molecule localization super-resolution microscopy have been limited due to insufficient availability of qualified fluorophores with favorable low duty cycles. The key for the new concept is that the “On” state of a redox-active fluorophore with unfavorable high duty cycle could be driven to “Off” state by electrochemical potential modulation and thus become available for single-molecule localization imaging. The new concept was carried out using redox-active cresyl violet with unfavorable high duty cycle as a model fluorophore by synchronizing electrochemical potential scanning with a single-molecule localization microscope. The two cytoskeletal protein structures, the microtubules from porcine brain and the actins from rabbit muscle, were selected as the model target structures for the conceptual imaging in vitro. The super-resolution images of microtubules and actins were obtained from precise single-molecule localizations determined by modulating the On/Off states of single fluorophore molecules on the cytoskeletal proteins via electrochemical potential scanning. Importantly, this method could allow more fluorophores even with unfavorable photophysical properties to become available for a wider and more extensive application of single-molecule localization microscopy.

electrochemical modulation↗

Effects of Soiling of Photovoltaic Modules and Systems in Brazil’s Climate Zones

This research presents a methodology for quantifying soiling loss in p-Si and CdTe photovoltaic modules through measurements from soiling stations installed in Belo Horizonte (-19.92° S, -43.99° W), Porto Alegre (-30.05° S, -51.17° W), Brotas de Macaúbas (12.0011° S, -42.6303° W), and Macapá (0.0356° N, -51.0705° W), in Brazil. The electrical parameters measured from photovoltaic modules are compared with precipitation data collected in the same location, with the objective of evaluating the behavior of the soiling ratio during the dry periods. Mathematical models determined the SRatio and SRate for each site (in compliance with the IEC-61324-1 monitoring standard [1]). The SRatio for short-circuit current and maximum power data from the modules were evaluated and compared, characterizing the potential effects of uniform and non-uniform soiling. In addition, a method for analyzing energy-production data of PV systems in order to extract the soiling rate was developed and is presented. The gravimetric soiling densities (mg/m2) was determined using the modeling by Coello and Boyle [2] and these are compared to data collected using the Figgis soiling microscope [3].

climate zone↗

User's Manual for Data for Validating Models for PV Module Performance

This user's manual describes performance data measured for flat-plate photovoltaic (PV) modules installed in Cocoa, Florida, Eugene, Oregon, and Golden, Colorado. The data include PV module current-voltage curves and associated meteorological data for approximately one-year periods. These publicly available data are intended to facilitate the validation of existing models for predicting the performance of PV modules, and for the development of new and improved models. For comparing different modeling approaches, using these public data will provide transparency and more meaningful comparisons of the relative benefits.

14 SOLAR ENERGY↗

Cooperative effort between Consorcio European Spallation Source--Bilbao and Oak Ridge National Laboratory spallation neutron source for manufacturing and testing of the JEMA-designed modulator system

The JEMA modulator was originally developed for the European Spallation Source (ESS) when Spain was under consideration as a location for the ESS facility. Discussions ensued and the Spallation Neutron Source Research Accelerator Division agreed to form a collaboration with ESS-Bilbao (ESS-B) consortium to provide services for specifying the requirements for a version of the modulator capable of operating twelve 550 kW klystrons, monitoring the technical progress on the contract with JEMA, installing and commissioning the modulator at SNS, and performing a 30 day full power test. This work was recently completed, and this report discusses those activities with primary emphasis on the installation and testing activities.

43 PARTICLE ACCELERATORS↗

PACT Module Design Acceptance Criteria (Industry)

For the PACT center to both develop testing protocols and provide service to the metal halide perovskite (MHP) PV community, PACT will seek modules (mini and full-sized) for testing purposes. To ensure both safety and high-quality samples PACT publishes acceptance criteria to define the minimum characteristics of modules the center will accept for testing. These criteria help to ensure we are accepting technologies that are compatible with our technical facilities and testing equipment and can transition to large scale commercial manufacturing. This module design acceptance criteria document is for industry partners and is different from the acceptance criteria for research partners (academia, national laboratories) partners.

14 SOLAR ENERGY↗

Durable Module Materials (DuraMAT) Consortium (Final Technical Report)

The DuraMAT Consortium brings together DOE national lab and university research capabilities with the photovoltaic (PV) and supply-chain industries to accelerate a sustainable, just, and equitable transition to zero carbon electricity generation by 2035 through our five core objectives: development of a central data resource for PV modules, multi-scale and multi-physics modeling, disruptive acceleration science, forensic tools for fielded modules, and materials solutions for more durable, reliable, and resilient modules.

14 SOLAR ENERGY↗