Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pulse generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Pulse shortening, spatial mode cleaning, and intense terahertz generation by filamentation in xenon

We performed a comprehensive study of filamentation in xenon. Due to its high nonlinear refraction index, but relatively low ionization potential, xenon can support filamentation at peak powers lower than in air. In our experiments, we studied pulse shortening, spatial mode cleaning, and generation of terahertz radiation. We observed that in xenon, self-compression is easily obtainable and terahertz radiation generation efficiency is significantly stronger as compared to air.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Injection and acceleration of electron bunch in a plasma wakefield produced by a chirped laser pulse

An ultrashort laser pulse propagating in plasma can excite a nonlinear plasma wakefield which can trap and accelerate charged particles up to GeV. One-dimensional analysis of electron injection, trapping, and acceleration by different chirped pulses propagating in plasma is investigated numerically. In this paper, we inject electron bunches in front of the chirped pulses. It is indicated that periodical chirped laser pulse can trap electrons earlier than other pulses. It is shown that periodical chirped laser pulses lead to decrease the minimum momentum necessary to trap the electrons. This is due to the fact that periodical chirped laser pulses are globally much efficient than nonchirped pulses in the wakefield generation. It is found that chirped laser pulses could lead to much larger electron energy than that of nonchirped pulses. Relative energy spread has a lower value in the case of periodical chirped laser pulses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical investigation of nanosecond pulsed discharge in air at above-atmospheric pressures

Here, this paper focuses on the multi-dimensional simulation of non-equilibrium plasma generated by nanosecond pulsed discharge in air, at pressure values higher than atmospheric. Voltage profiles and electrode geometry closely match those from a complementary experimental study. Simulations highlight the transition between different post-discharge plasma regimes at increasing pressure and tie the characteristics of the streamers to the electric field distribution in the gap between the electrodes. Results from simulations match experimental observations and qualitatively capture the experimental trend in terms of regime transition pressure and structure of the streamers. As a result, this paper validates a numerical tool that captures the physical and chemical properties of the low-temperature plasma and contributes to expand the understanding of low-temperature plasma ignition processes.

42 ENGINEERING↗

Design and Implementation of a Facility for Discovering New Scintillator Materials

We describe the design and operation of a high-throughput facility for synthesizing thousands of inorganic crystalline samples per year and evaluating them as potential scintillation detector materials. This facility includes a robotic dispenser, arrays of automated furnaces, a dual-beam X-ray generator for diffractometery and luminescence spectroscopy, a pulsed X-ray generator for time response measurements, computer-controlled sample changers, an optical spectrometer, and a network-accessible database management system that captures all synthesis and measurement data.

36 MATERIALS SCIENCE↗

Narrow-bandwidth Tunable Picosecond Pulses in the Visible Produced by Noncollinear optical parametric Amplification with a Chirped Blue Pump

Narrow-bandwidth ( ~27 cm -1 ) tunable picosecond pulses from 480 nm–780 nm were generated from the output of a 1 kHz femtosecond titanium:sapphire laser system using a type I noncollinear optical parametric amplifier (NOPA) with chirped second-harmonic generation (SHG) pumping. Unlike a femto second NOPA, this system utilizes a broadband pump beam, the chirped 400 nm SHG of the Ti:sapphire fundamental, to amplify a monochromatic signal beam (spectrally-filtered output of a type II collinear OPA). Optimum geometric conditions for simultaneous phase- and group-velocity matching were calculated in the visible spectrum. This design is an efficient and simple method for generating tunable visible picosecond pulses that are synchronized to the femtosecond pulses.

42 ENGINEERING↗

Connecting Lab-Based Attosecond Science with FEL research

In the last few years laboratory-scale femtosecond laser-based research using XUV light has developed dramatically following the successful development of attosecond laser pulses by means of high-harmonic generation. Using attosecond laser pulses, studies of electron dynamics on the natural timescale that electronic processes occur in atoms, molecules and solids can be contemplated, providing unprecedented insight into the fundamental role that electrons play in photo-induced processes. In my talk I will briefly review the present status of the attosecond science research field in terms of present and foreseen capabilities, and discuss a few recent applications, including a first example of the use of attosecond laser pulses in molecular science. In addition, I will discuss very recent results of experiments where photoionization of dynamically aligned molecules is investigated using a high-harmonics XUV source. Photoionization of aligned molecules becomes all the more interesting if the experiment is performed using x-ray photons. Following the absorption of x-rays, ejected photoelectrons can be used as a probe of the (time-evolving) molecular structure, making use of intra-molecular electron diffraction. This amounts, as some have stated, to “illuminating the molecule from within”. I will present the present status of our experiments on this topic making use of the FLASH free electron laser in Hamburg. Future progress in this research field not only depends on the availability of better and more powerful light sources, but also requires sophisticated detector strategies. In my talk I will explain how we are trying to meet some of the experimental challenges by using the Medipix family of detectors, which we have already used for time- and space-resolved imaging of electrons and ions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A tilted pulse-front setup for femtosecond transient grating spectroscopy in highly non-collinear geometries

We demonstrate a tilted pulse-front transient grating (TG) technique that allows to optimally utilize time resolution as well as TG line density while probing under grazing incidence as typically done in extreme ultraviolet (EUV) or soft x-ray (SXR) experiments. Our optical setup adapts the pulse front tilt of the two pulses that create the TG to the grazing incident pulse. Here, we demonstrate the technique using all 800 nm femtosecond laser pulses for TG generation on a vanadium dioxide film. We probe that grating via diffraction of a third 800 nm pulse. The time resolution of 90 fs is an improvement by a factor of 30 compared to our previous experiments on the same system. Lastly, the scheme paves the way for EUV and SXR probing of optically induced TGs on any material.

36 MATERIALS SCIENCE↗

Powerplexer

An electrical power distribution system is described for use in providing different dc voltage levels. A circuit is supplied with DC voltage levels and commutates pulses for timed intervals onto a pair of distribution wires. The circuit is driven by a command generator which places pulses on the wires in a timed sequence. The pair of wires extend to voltage strippers connected to the various loads. The voltage strippers each respond to the pulse dc levels on the pair of wires and form different output voltages communicated to each load.

Woods, J. M.↗

Note: Design and initial results of a multi-pulsed intense electron beam source

A multi-pulsed intense electron beam source is introduced, including the design and the initial experimental results. The source can generate a burst of three pulses of intense electron beams with energy of 2–3 MeV and beam intensities of around 2.5 kA. An inductive adder is chosen to generate the pulsed diode voltages and a dispenser cathode is chosen to emit electron beams. The test results indicate that the design of the source is reliable. The multi-pulsed diode voltage is up to 2.5 MV and the beam intensities are more than 2 kA at the exit of the source with small variation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dramatic dwindling of the power spectrum of high order harmonics by shrinking of the gap size in bowtie nanostructures

Our work is based on high harmonic generation in a gaseous medium (helium ion), by exploiting gold bowtie nanostructures as laser field amplifiers. As the result of emission of a laser pulse, the wave function of the atom varies with time; so, it is necessary to solve 1D time-dependent Schrödinger equation by means of split operator method. By illumination of a short duration, long wavelength three color laser pulse inside the gap, the enhanced field not only changes with time, but also varies in space. In this work we considered this space inhomogeneity in linear and nonlinear schemes. We show that in nonlinear case, the plateau region is more extended. We also show that in larger gaps, cutoff occurs on higher frequencies. But limitation of electron motion in bowtie nanostructures leads to the choice of an optimum 16 nm gap size in our case. We predict that, by the superposition of supercontinuum harmonics, a 26 attosecond pulse can be generated.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Quantum path control in harmonic generation by temporal shaping of few-optical-cycle pulses in ionizing media

Temporal reshaping of the electric field of few-optical-cycle pulses in a low-density ionizing gas has been used to achieve control of the electron trajectories in the process of high-order harmonic generation. As a result of such a quantum path control mechanism, isolated or multiple attosecond pulses have been produced, depending on the carrier-envelope phase of the driving field. In particular, complete spectral tunability of the harmonic peaks over the whole spectral range has been demonstrated. Experimental results have been interpreted using a nonadiabatic three-dimensional propagation model and a nonadiabatic stationary phase model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimization of Reflectance Pulse Oximetry Sensors Final Report CRADA No. TC-485-93

The focus of this Cooperative Research and Development Agreement (CRADA) was to design a next generation of reflectance pulse oximeter sensor. Nellcor wanted to develop an optimized reflectance pulse oximeter sensor with reduced sensitivity to the placement of the sensor (and to composition of the sampled tissue) while accurately measuring the perfusion of the tissue (i.e. oxygen saturation). Nellcor Inc. changed the company name to Nellcor-Puritan Bennett, Inc. in 1995.

47 OTHER INSTRUMENTATION↗

An “Off-the-Shelf” System for Intraprocedural Electrical Current Evaluation and Monitoring of Irreversible Electroporation Therapy

IntroductionIrreversible electroporation (IRE) ablation uses a series of brief electric pulses to create nanoscale defects in cell membranes, killing the cells. It has shown promise in numerous soft-tissue tumor applications. Larger voltages between electrodes will increase ablation volume, but exceeding electrical limits may risk damage to the patient, cause ineffective therapy delivery, or require generator restart. Monitoring electrical current for these conditions in real-time enables managing these risks. This capacity is not presently available in clinical IRE generators.MethodsWe describe a system using a Tektronix TCP305 AC/DC Current Probe connected to a TCPA300 AC/DC Current Probe Amplifier, which is read on a computer using a Protek DSO-2090 USB computer-interfacing oscilloscope. Accuracy of the system was tested with a resistor circuit and by comparing measured currents with final outputs from the NanoKnife clinical electroporation pulse generator.ResultsAccuracy of measured currents was 1.64 ± 2.4 % relative to calculations for the resistor circuit and averaged 0.371 ± 0.977 % deviation from the NanoKnife. During clinical pulse delivery, the system offers real-time evaluation of IRE procedure progress and enables a number of methods for identifying approaching issues from electrical behavior of therapy delivery, facilitating protocol changes before encountering therapy delivery issues.ConclusionsThis system can monitor electrical currents in real-time without altering the electric pulses or modifying the pulse generator. This facilitates delivering electric pulse protocols that remain within the optimal range of electrical currents—sufficient strength for clinically relevant ablation volumes, without the risk of exceeding safe electric currents or causing inadequate ablation.

60 APPLIED LIFE SCIENCES↗

The Electrical Characteristics of a Filamentary Dielectric Barrier Discharge

The electrical characteristics of a filamentary dielectric barrier discharge using parallel-plate electrodes geometry were statistically studied. The DBD's system was powered by a 50 Hz power supply and operated at atmospheric pressure. The influence of the air gap and position of dielectric on the discharge had been investigated. It was found that the air gap distance and position of dielectric had significant influence on the discharge current pulse. The results showed that discharge with large distance between the high voltage electrode and the dielectric would generate higher current pulses during the positive cycle. The discharge energy of single pulse was also determined.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dislocation structure produced by an ultrashort shock pulse

We found an ultrashort shock pulse driven by a femtosecond laser pulse on iron generates a different dislocation structure than the shock process which is on the nanosecond timescale. The ultrashort shock pulse produces a highly dense dislocation structure that varies by depth. According to transmission electron microscopy, dislocations away from the surface produce microbands via a network structure similar to a long shock process, but unlike a long shock process dislocations near the surface have limited intersections. Considering the dislocation motion during the shock process, the structure near the surface is attributed to the ultrashort shock duration. This approach using an ultrashort shock pulse will lead to understanding the whole process off shock deformation by clarifying the early stage.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Capillary plasma jet: A low volume plasma source for life science applications

In this letter, we present results from multispectroscopic analysis of protein films, after exposure to a peculiar plasma source, i.e., the capillary plasma jet. This plasma source is able to generate very small pulsed plasma volumes, in kilohertz range, with characteristic dimensions smaller than 1 mm. This leads to specific microscale generation and transport of all plasma species. Plasma diagnosis was realized using general electrical and optical methods. Depending on power level and exposure duration, this miniature plasma jet can induce controllable modifications to soft matter targets. Detailed discussions on protein film oxidation and chemical etching are supported by results from absorption, X-ray photoelectron spectroscopy, and microscopy techniques. Further exploitation of principles presented here may consolidate research interests involving plasmas in biotechnologies and plasma medicine, especially in patterning technologies, modified biomolecule arrays, and local chemical functionalization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the Pointing Angle of Electron Beams from Laser Wakefield Accelerators

Laser wakefield accelerators offer electron beams which could be useful for many applications. However, the problem of stabilizing the electron beam parameters has not been resolved yet. Here, we propose a method to minimize the electron beam pointing and report the generation of a relativistic electron beam with a stabilized pointing angle of 2 mrad (rms). This was achieved by using asymmetric non-relativistic laser pulses interacting with low-density helium gas jet. In such a weakly-nonlinear regime, symmetric laser pulses were neither able to generate reproducible nor stable electron beams. Thus, we propose asymmetric laser pulses for generating electron beams having stable and small pointing angles from laser-plasma accelerators.

43 PARTICLE ACCELERATORS↗