Search NASA⌕ Search

SEARCH · Search NASA

Results for “Retrofitting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Analysis of hydrogen as a Transportation Fuel FY17 Report

This report summarizes the results of literature reviews, surveys and analyses performed to evaluate the potential of hydrogen-fueled vehicles to be an economically viable transportation alternative. Five existing and important drivers of expanding hydrogen-fueled transportation adoption are multi-billion dollar sales reservations of Nikola Class 8 trucks, CALSTART viability analysis of hybrid-hydrogen drayage trucks in the shipyard cargo application, analysis showing economic advantages of Fuel Cell Electric Vehicles (FCEV)s over Battery Electric Vehicles (BEV)s beginning at 150-mile ranges, the announcement of a commercial 5kg electrolyzer, and commercial plans or vehicle availability by nine vehicle manufacturers of FCEV passenger vehicles. But hydrogen infrastructure availability needed to support broad adoption of hydrogen-fueled vehicles is limited to less than 50 publicly-available refueling stations, primarily in California. The demand side (consumer) economics associated with FCEV adoption showed strong economic sensitivity to the original vehicle’s fuel economy (mpg), distance traveled, and hydrogen (H2) generation costs. Seven use cases were used to evaluate the broad range of potential FCEV purchasers, including autonomous vehicle applications. Each consumer use case analysis resulted in a different hydrogen fuel cost that would be equivalent to the current fuel cost being paid by the consumer. The H2 generation costs (supply side) were sensitive to the volume of H2 supplied and H2 production costs needed to repay H2 supply facility capital costs and produce competitively-priced energy. H2FAST was used to more accurately incorporate capital, maintenance and production costs into a viable H2 supply cost to the consumer. When the H2 generation and consumer economics were combined, several applications with positive economics became clear. The availability of low-cost hydrogen pipeline connections, and therefore low-cost hydrogen, greatly benefits the California drayage truck application with hybrid-hydrogen retrofits being repaid within seven years. Class 8 trucks could also take advantage of these low-cost, but regional hydrogen supplies. In addition, the IVYS electrolyzer-based hydrogen generation product showed the potential to deliver hydrogen economically in an urban or freeway off-ramp setting to a limited number of passenger vehicles in areas with low-cost electricity. These positive, manually developed results show the need to develop more advanced tools to provide an expanded evaluation of the economics of hydrogen-based fuel applications. The use cases evaluated showed significant potential for hydrogen-fueled vehicles to have a sustainable impact as a transportation fuel. The positive impact is not limited to transportation fuels, but also grid resilience and flexibility through the use of controllable and variable electrolyzer output to rapidly adjust to changing grid conditions and enable greater integration of solar and wind generated power. This capability would directly enable alternative fuel vehicles to impact energy consumption, GHG emissions, and the economy at the regional and national levels.

08 HYDROGEN↗

Pollutant Concentrations and Emission Rates from Scripted Natural Gas Cooking Burner Use in Nine Northern California Homes

METHODS: Combustion pollutant concentrations were measured during the scripted operation of natural gas cooking burners in nine homes. In addition to a base condition of closed windows, no forced air unit (FAU) use, and no mechanical exhaust, additional experiments were conducted while operating an FAU and/or vented range hood. Test homes included a 26m2 two-room apartment, a 134m2 first floor flat, and seven detached homes of 117–226m2. There were four single-story, four two-story and one 1.5 story homes. Cooktop use entailed boiling and simmering activities, using water as a heat sink. Oven and broiler use also were simulated. Time-resolved concentrations of carbon dioxide (CO2), nitric oxide (NO), nitrogen oxides (NOX), nitrogen dioxide (NO2), particles with diameters of 6 nm or larger (PN), carbon monoxide (CO), and fine particulate matter (PM2.5) were measured in the kitchen (K) and bedroom area (BR) of each home. CO2, NO, NO2, and PN data from sequential experiments were analyzed to quantify the contribution of burner use to the highest 1h and 4h time-integrated concentrations in each room. RESULTS: Four of the nine homes had kitchen 1h NO2 exceed the national ambient air quality standard (100 ppb). Two other homes had 1h NO2 exceed 50 ppb in the kitchen, and three had 1h NO2 above 50 ppb in the bedroom, suggesting substantial exposures to anyone at home when burners are used for a single substantial event. In all homes, the highest 1h kitchen PN exceeded 2 x105 cm-3-h, and the highest 4h PN exceeded 3 x105 cm-3-hr in all homes. The lowest 1h kitchen/bedroom ratios were 1.3–2.1 for NO in the apartment and two open floor plan homes. The largest K/BR ratios of 1h NO2 were in a two-story 1990s home retrofitted for deep energy savings: ratios in this home were 3.3 to 6.6. Kitchen 1h ratios of NO, NO2 and PN to CO2 were used to calculate fuel normalized emission factors (ng J-1). Range hood use substantially reduced cooking burner pollutant concentrations both in the kitchen and bedroom of several homes. A hood with large capture volume and a measured flow of 108 L/s reduced concentrations 80-95%. IMPLICATIONS: These measurements demonstrate that operation of natural gas cooking burners without venting can cause short-term kitchen concentrations of NO2 to exceed the US outdoor health standard, and can elevate concentrations of NO, NO2, and ultrafine particles throughout the home. Results are generally consistent with a recent simulation study that estimated widespread 1h NO2 exposures exceeding 100 ppb in homes that use gas burners without venting. While operating a venting range hood can greatly reduce pollutant levels from burner use (and presumably from cooking as well), performance varies widely across hoods. Increased awareness of the need to ventilate when cooking would substantially reduce in-home exposure to NO2 and ultrafine particles in California homes. Helping consumers select effective hoods, for example by publishing capture efficiency performance ratings, also would help reduce exposure.

54 ENVIRONMENTAL SCIENCES↗

Coal-Powered Electric Generating Unit Efficiency and Reliability Dialogue: Summary Report

Coal continues to play a critical role in powering the Nation’s electricity generation, especially for baseload power plants. With aging coal generation assets facing decreased performance due to the state of the equipment, and with challenges exacerbated by the current market pressures on the coal sector, there are opportunities to advance early-stage technologies that can retrofit or replace equipment components. These changes will eventually result in significant improvements in plant performance once further developed and deployed by industry. Research and development in areas such as materials, fluid dynamics, fuel properties and preparation characteristics, and a new generation of plant controls can lead to new components and systems that can help improve the efficiency and reliability of coal-fired power plants significantly, allowing these assets to continue to provide baseload power. Coal stockpiles at electricity generation plants are typically large enough to provide 30 to 60 days of power prior to resupply—significantly enhancing the stability and reliability of the U.S. electricity sector. Falling prices for non-dispatchable renewable energy and mounting environmental regulations, among other factors, have stimulated efforts to improve the efficiency of these coal-fired electric generating units (EGUs). In addition, increased reliance on natural gas and non-dispatchable energy sources has spurred efforts to further increase the reliability of coal EGUs. The Coal Powered EGU Efficiency and Reliability Dialogue brought together stakeholders from across the coal EGU industry to discuss methods for improvement. Participants at the event reviewed performance-enhancing innovations in coal EGUs, discussed the potential for data-driven management practices to increase efficiency and reliability, investigated the impacts of regulatory compliance on coal EGU performance, and discussed upcoming challenges for the coal industry. This report documents the key findings and research suggestions discussed at the event. Discussions at the workshop will aid DOE in developing a set of distinct initiatives that can be pursued by government and industry to realize promising technological pursuits. DOE plans to use the results of the Dialogue coupled with ongoing technical analysis of efficiency opportunities within the coal-fired fleet, and additional studies to develop a comprehensive strategy for capitalizing on thermal efficiency improvements. Expected Power Plant Efficiency Improvements include developing cost-effective, efficient, and reliable technologies for boilers, turbines, and sensors and controls to improve the reliability and efficiency of existing coal-based power plants. The Office of Fossil Energy at DOE plans to work with industry to develop knowledge pertaining to advanced technologies and systems that industry can subsequently develop. These technologies and systems will increase reliability, add operational flexibility and improve efficiency, thereby providing more robust power generation infrastructure. The following table lists the research suggestions and questions for further investigation that were identified by participants in each session of the dialogue.

01 COAL, LIGNITE, AND PEAT↗

STTR Phase I: Low-Cost, High-Accuracy, Whole-Building Carbon Dioxide Monitoring for Demand Control Ventilation

This STTR Phase I project assessed the feasibility of a new CO 2 sensing system optimized for low-cost, high-accuracy, whole-building monitoring for use in demand control ventilation. The focus was on the development of a wireless networking platform and associated firmware to provide signal conditioning and conversion, fault- and disruptiontolerant networking, and multi-hop routing at building scales to avoid wiring costs. Early exploration of a bridge (or “gateway”) to direct digital control services was also explored. Results of the project contributed to an improved understanding of a new electrochemical sensor for monitoring indoor CO 2 concentrations, as well as the electronics and networking infrastructure required to deploy those sensors at building scales. New knowledge was acquired concerning the sensor’s accuracy, environmental response, and failure modes, and the acquisition electronics required to achieve accuracy over a wide range of CO 2 concentrations. The project demonstrated that the new sensor offers repeatable correspondence with commercial optical sensors, with supporting electronics that offer gain accuracy within 0.5%, and acquisition accuracy within 1.5% across three orders of magnitude variation in generated current. Considering production, installation, and maintenance costs, the technology presents a foundation for achieving whole-building CO 2 sensing at a price point below $0.066 / sq-ft – meeting economic feasibility criteria established by the Department of Energy. The technology developed under this award addresses obstacles on the critical path to enabling whole-building CO 2 sensing and demand control ventilation in commercial retrofits, small commercial buildings, residential complexes, and other highpotential structures that have been slow to adopt these technologies. It presents an opportunity to significantly reduce energy use throughout the United States.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and Implementation of Air Barrier Systems for New and Existing Buildings

A Cooperative Research and Development Agreement (CRADA) was established between Oak Ridge National Laboratory (ORNL) and the Air Barrier Association of America (ABAA) to assess key aspects that influence the performance of air barrier systems commonly use d in residential and commercial buildings. This collaboration was intended to include laboratory experiments and evaluations in a natural exposure test facility, as well as building envelope retrofits that improved the airtightness of existing buildings. Even though the Department of Energy discontinued funding this work after two years, the gathered results provided insight on the effect of air leakage on energy use and material durability, as well as the contribution of common air leaks to energy consumption. Furthermore, ORNL and ABAA have continued collaborating in other projects such as the development of a free online calculator that estimates energy and cost savings due to improvements in airtightness.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

RFA for Solar/Geothermal Hybrid Thermal Energy Storage Modeling: Cooperative Research and Development Final Report, CRADA Number CRD-16-646

Hyperlight Energy is an innovative concentrated solar power (CSP) company whose business charter is to commercialize a disruptively low-cost, CSP collector system that is ultimately for providing heat for solar thermal/geothermal hybrid power plants, process heat applications (e.g., enhanced oil recovery), and solar thermal power generation. Hyperlight's CSP collector system utilizes a linear Fresnel reflector (LFR) configuration. This LFR configuration consists of mirrors mounted in low-cost, precision plastic extrusions, which are integrated into raft assemblies and floated on low-cost, sealed waterbeds. Hyperlight's CSP collector technology has been developed under private equity investment, government grant and commercial funding. Hyperlight has been awarded a 1.5-million DOE COLLECTS contract with an additional 1.6 million in matched funds from private investment and the California Energy Commission. This DOE project will support the final steps of product development for bulk commercialization and deployment of the Hyperlight CSP collector system. The work will culminate in a final operational deployment at a commercially relevant site. Several such site options are currently under evaluation, including two geothermal sites. Hyperlight identified a very low-cost way to put renewable energy electrons on the grid at peak times, upgrading underutilized geothermal plants with Hyperlight's low cost CSP and thermal energy storage (TES). While Hyperlight's CSP collector work is maturing quickly for commercial pilot launch, an optimal TES system for solar thermal/geothermal hybridization needs to be evaluated and ultimately developed so Hyperlight can develop commercial retrofit projects at a scale of hundreds of megawatts of renewable energy power output at sites across the United States, followed by greenfield projects in a multi-GW sized market.

15 GEOTHERMAL ENERGY↗

Final CRADA Report for Enhanced and Miniaturized Wireless Valve Position Indicator Prototype

Most operating nuclear power plants (NPPs) in the United States have received approval to extend their operating licenses to 60 years. Now the nuclear industry is preparing to extend operating licenses to 80 years. While NPPs are preparing for extensions (60 years and beyond), the nuclear industry is facing a unique economic sustainability challenge in the current energy market. According to the Nuclear Energy Institute (NEI), generating costs of U.S. reactors have risen by 28% over the last 12 years, which is impacting the competitiveness of nuclear power in a market being increasingly penetrated by natural gas and renewable energy. This is partly because of the fact that the present nuclear work practice is dependent on a large technical staff which results in high operation and maintenance (O&M) costs, accounting for approximately 66% of the total operating cost. To address these concerns and abide by the NEI’s “Delivering the Nuclear Promise Initiative,” the U.S. utilities are embracing digitalization of their work practice to lower the O&M costs and increase productivity and efficiency while maintaining a safe and reliable operation. To address these above-mentioned concerns, Idaho National Laboratory (INL) researchers (proposal team) have developed a wireless valve position indication (VPI) sensor system that can be retrofitted on three main manual valve types (extendible to other manual valve types) to replace manual valve position verification with digital verification and enable online monitoring of manual valves. The developed technology 1) is evaluated for electromagnetic interference, 2) has a low power consuming and miniaturized electronic board, 3) is mounted on adjustable and reconfigurable sensor mounting unit that can fit on an actual flow-loop (at Idaho State University-ISU) to enable online monitoring of manual valve types without any valve body modification, and 4) ensures robust, secure, and reliable real-time communication of manual valve position.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Integrated Supercritical System for Efficient Produced Water Treatment and Power Generation

The main goal of this project was to evaluate the feasibility of an integrated supercritical (SC) water desalination and power generation system for treatment of produced waters from CO 2 sequestration, oil production, and coal-bed methane recovery. This system may offer a transformative approach to generating power from coal or natural gas (NG) and purifying saline water or produced water with high total dissolved solids (TDS) in a zero-liquid discharge plant. The closed-loop steam cycle of conventional power plants was replaced with an open-loop steam cycle that heated the pretreated produced water above the SC point of water (374 °C and 221 bar) to precipitate and separate the salts dissolved in the water. After separation of the precipitated salt, the SC steam required further treatment to reduce the salt content from ~100 mg/L (ppm) to <1 ppm to make it suitable for use in turbines for power generation. A SC membrane distillation unit was used to polish the SC steam, which could be sent through a series of turbines for power generation, and the steam exiting the low-pressure turbine could be condensed by cooling water to produce pure water. Project tasks included a process simulation and a techno-economic evaluation of the integrated system; design and assembly of SC salt precipitation and membrane distillation systems; development and characterization of advanced carbon membranes for SC membrane distillation; and pretreatment, desalination, and purification of different produced water samples with salt concentrations of 30,000–200,000 ppm to a high-purity (<1 ppm) level. Process simulations were performed for 550 MW SC coal-fired or NG baseline cases and various scenarios for the proposed integrated SC system using produced water as the water source and coal or NG as the fuel source. Simulation results indicated that the net plant efficiency loss of the proposed SC cogeneration process would be in the range of <1% to ~4%, in which NG and lower TDS produced water cases would have higher efficiencies. The proposed process for coal-fired cases could provide all water needs for the power generation process and generate additional pure water for beneficial use. A techno-economic analysis was performed to estimate the cost of produced water treatment (dollars /kgal of treated water) by conventional treatment processes compared with the proposed cogeneration process. The cost estimation for the proposed cogeneration system included the cost of pretreatment, the cost of power loss to integrate the water desalination process into the power generation system, and the cost of plant modification or retrofitting. The cost of produced water treatment was calculated by assuming three different scenarios in which converting a baseline power plant to the proposed cogeneration plant would increase the cost of the boiler and feed water system by 10%, 50%, and 100%. Results indicated that the cost of produced water treatment, even with a 100% cost increase, was in the range of $8.6–11.6 dollars per kgal, which is about half of the treatment cost by conventional methods. The cost of produced water treatment by the proposed cogeneration system could be further reduced or a considerable income could be generated if the values of saltwater and freshwater products are considered. Overall, the techno-economic analysis results indicated that the proposed integrated SC system could potentially treat produced water at a cost significantly lower than the cost of produced water treatment by conventional technologies. To evaluate the feasibility of the proposed treatment system at a laboratory scale, a SC salt precipitation and membrane distillation system was designed and fabricated to treat a simulated brine or pretreated produced water by precipitating salts and further polishing the SC steam containing ~100 ppm salts to a high-purity steam. Through baseline tests with NaCl solutions, with concentrations ranging from 30,000 to 200,000 ppm, it was demonstrated that concentrated feed solutions could be treated by precipitating salt at SC conditions to a TDS level of 130 ppm. Produced water samples were collected from a potential CO 2 sequestration site, a coal-bed methane site, and an oilfield in Illinois. Representative samples were characterized for various water quality parameters, including pH; turbidity; conductivity; and concentrations of selected anions, cations, alkalinity, dissolved organic carbon, total suspended solids, TDS, and total petroleum hydrocarbons. The produced water samples were first treated by conventional pretreatment methods to remove residual oil, dissolved organic matter, and scale-forming species. Pretreatment methods included coagulation, sedimentation, filtration, activated carbon adsorption, and ion-exchange adsorption. Pretreated produced waters were treated at SC conditions in which salts were precipitated. Analysis of treated samples revealed that the concentration of Na (the main cation) in produced waters was reduced dramatically from 14,000–47,400 ppm in the feed to 21–80 ppm in treated waters. Concentrations of other main cations (Ca, Mg, Sr, K) also decreased significantly from initial values of ~1,000–22,000 ppm to ~1 ppm or less. However, a significant increase in the concentrations of Fe, Ni, Cu, and Co was observed, mainly caused by leaching of these elements from the system (vessels, filters, tubing), which is manufactured from alloys containing Fe, Ni, Cu, and Co. To polish the SC steam containing a salt content of ~100 ppm to a high-purity level of <1 ppm, a SC membrane distillation treatment using carbon membranes was employed. Different types of self-standing or supported carbon membranes were developed from graphite, graphene, carbon nanotubes, carbon nanofibers, and pyrolytic carbon. Screening tests revealed that only a limited number of developed carbon membranes were suitable for the purification of steam at SC conditions. Membranes that were either fragile and lacked mechanical strength or had large pores and showed limited salt rejection (<20%) were found to be unsuitable for the purification of SC steam. Promising carbon membranes that were successfully tested for purifying SC steam included two graphite membranes (i.e., AF-5, a porous graphite material, and FGS, a flexible graphite sheet) and a carbon nanotube membrane grown on a Hastelloy substrate and then further modified using a proprietary method (i.e., membrane C). The AF-5 membrane exhibited a stable water flux of ~50 kg/m 2 ∙h and ~40% salt rejection. The FGS membrane had a high salt rejection of 95%–98% but a lower water flux of ~15 kg/m 2 ∙h. Membrane C showed an extremely high flux of 200-800 kg/m 2 ∙h, which is one order of magnitude higher than the water flux of conventional membranes. Membrane C also exhibited 87%–93% salt rejection. Overall, a two-stage or multistage polishing treatment by these membranes could lower the salt content of the SC steam from initial values of ~100–200 ppm to the steam quality of <1 ppm or to parts per billion levels required for the power cycle.

20 FOSSIL-FUELED POWER PLANTS↗

The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures: January 2012 - September 2016

This is the complete set of Uniform Methods Project protocols for determining energy efficiency savings for specific measures, all within one report. The report includes the following chapters: Chapter 1: Introduction. Chapter 2: Commercial and Industrial Lighting Evaluation Protocol. Chapter 3: Commercial and Industrial Lighting Controls Evaluation Protocol. Chapter 4: Small Commercial and Residential Unitary and Split System HVAC Cooling Equipment-Efficiency Upgrade Evaluation Protocol. Chapter 5: Residential Furnaces and Boilers Evaluation Protocol. Chapter 6: Residential Lighting Evaluation Protocol. Chapter 7: Refrigerator Recycling Evaluation Protocol. Chapter 8: Whole-Building Retrofit with Consumption Data Analysis Evaluation Protocol. Chapter 9: Metering Cross-Cutting Protocol. Chapter 10: Peak Demand and Time-Differentiated Energy Savings Cross-Cutting Protocol. Chapter 11: Sample Design Cross-Cutting Protocol. Chapter 12: Survey Design and Implementation for Estimating Gross Savings Cross-Cutting Protocol. Chapter 13: Assessing Persistence and Other Evaluation Issues Cross-Cutting Protocol. Chapter 14: Chiller Evaluation Protocol. Chapter 15: Commercial New Construction Evaluation Protocol. Chapter 16: Retrocommissioning Evaluation Protocol. Chapter 17: Residential Behavior Evaluation Protocol. Chapter 18: Variable Frequency Drive Evaluation Protocol. Chapter 19: HVAC Controls (DDC/EMS/BAS) Evaluation Protocol. Chapter 20: Data. Center IT Efficiency Measures Evaluation Protocol. Chapter 21: Estimating Net Savings - Common Practices. Chapter 22: Compressed Air Evaluation Protocol. Chapter 23: Combined Heat and Power Evaluation Protocol. Chapter 24: Strategic Energy Management (SEM) Evaluation Protocol

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

NREL Energy Performance Testing of Asetek's RackCDU System on a Single Rack of Twin Blade Servers: Cooperative Research and Development Final Report, CRADA Number CRD-13-518

The project will entail Asetek retrofitting 1 - 2 compute racks of servers at the National Renewable Energy Laboratory (NREL) to test and validate RackCDU's cooling performance and long-term reliability. The project will also entail measuring and reporting energy savings under a real workload by comparing total power input to the system vs. total heat removed by liquid and air. Direct measurements will be made to compare and contrast energy consumption and performance both before and after RackCDU installation. The scope of this project is strictly demonstration and feedback on the system. No development work will be performed under this CRADA.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Cost Reduction Potential of Vertical Bore Ground Heat Exchanger (Final)

The geothermal heat pump (GHP), also referred to as a ground source heat pump, is a proven technology that can provide space conditioning and water heating with efficiencies higher than conventional heating, ventilation, and air-conditioning (HVAC) systems. This technology possesses great potential to become a mainstream technology for satisfying the thermal demands in the built environment. Analysis from the ongoing Geothermal Vision Study indicates that 100% retrofitting of commercial and residential markets with GHPs has the potential to save on the order of 6 quadrillion Btu per year (Liu et al. 2017). However, the current high installation costs and long payback periods limit the attractiveness of GHP installation in the United States. The cost of installing ground heat exchangers (GHXs) used for GHPs accounts for more than 30% of the total cost of a GHP system (NYSERDA 2017), and it is the biggest contributor to the cost premium of GHPs compared with conventional HVAC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

In-Cylinder Diagnostics to Overcome Efficiency Barriers in Natural Gas Engines (LDRD 200166)

The high-level objective of this project is to solve national-security problems associated with petroleum use, cost, and environmental impacts by enabling more efficient use of natural-gas-fueled internal combustion engines. An improved science-base on end-gas autoignition, or “knock,” is required to support engineering of more efficient engine designs through predictive modeling. An existing optical diesel engine facility is retrofitted for natural gas fueling with laser-spark-ignition combustion to provide in-cylinder imaging and pressure data under knocking combustion. Zero-dimensional chemical-kinetic modeling of autoignition, adiabatically constrained by the measured cylinder pressure, isolates the role of autoignition chemistry. OH* chemiluminescence imaging reveals six different categories of knock onset that depend on proximity to engine surfaces and the in-cylinder deflagration. Modeling results show excellent prediction regardless of the knock category, thereby validating state-of-the-art kinetic mechanisms. The results also provide guidance for future work to build a science base on the factors that affect the deflagration rate.

33 ADVANCED PROPULSION SYSTEMS↗

Multifamily Tool for Energy Audits (MulTEA) Engineering Manual (Version 1)

The Multifamily Tool for Energy Audits (MulTEA) is an energy audit tool designed to provide auditors with an improved energy simulation tool for multifamily buildings and an improved tool for identifying cost-effective energy-efficiency retrofit measures for multifamily buildings. MulTEA is designed specifically to help states and local weatherization agencies implement the Department of Energy (DOE) Weatherization Assistance Program. MulTEA was developed jointly by the Oak Ridge National Laboratory (ORNL) and the Lawrence Berkeley National Laboratory (LBNL). MulTEA is part of ORNL’s web-based Weatherization Assistant suite of audit tools (https://weatherization.ornl.gov/softwaredescription/). The energy calculation engine including the DOE- 2 simulation model and supplementary calculation modules is shared by MulTEA and LBNL’s Home Energy Saver pro (HESpro) (http://hespro.lbl.gov/pro/). On the ORNL side, the energy calculation engine is coupled with a user interface and output reporting capabilities based on Weatherization Assistance Program regulations and guidelines pertinent to MulTEA. On the LBNL side, the same engine will be used in HESpro to expand it to handle multifamily buildings. MulTEA is designed to address small and large multifamily buildings with decentralized and centralized heating, ventilation, and air-conditioning (HVAC) and domestic hot water (DHW) systems. Version 1 of MulTEA addresses small multifamily buildings with decentralized HVAC systems, and decentralized or centralized DHW systems. The capability to model large buildings and centralized HVAC systems will be incorporated in Version 2.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tracking the Sun: Installed Price Trends for Distributed Photovoltaic Systems in the United States - 2018 Edition

Berkeley Lab’s Tracking the Sun report series is dedicated to summarizing installed prices and other trends among grid-connected, distributed solar photovoltaic (PV) systems in the United States. The present report, the 11th edition in the series, focuses on systems installed through year-end 2017, with preliminary trends for the first half of 2018. As in years past, the primary emphasis is on describing changes in installed prices over time and variation in pricing across projects based on location, project ownership, system design, and other attributes. New to this year, however, is an expanded discussion of other project characteristics in the large underlying data sample. Future editions will include more of such material, beyond the report’s traditional focus on installed pricing. The trends described in this report derive primarily from project-level data reported to state agencies and utilities that administer PV incentive programs, solar renewable energy credit (SREC) registration systems, or interconnection processes. In total, data were collected and cleaned for more than 1.3 million individual PV systems, representing 81% of U.S. residential and non-residential PV systems installed through 2017. The analysis of installed pricing trends is based on a subset of roughly 770,000 systems with available installed price data. Key findings from this year’s report include the following: -Installed Prices Continued to Fall through 2017 and into 2018. National median installed prices in 2017 were $3.7 per watt (W) for residential systems (a $0.2/W or 6% decline from the prior year), $3.1/W for small non-residential systems (a $0.4/W or 11% decline), and $2.2/W (a $0.1/W or 5% decline) for large non-residential systems. Data for the first half of 2018 show an additional drop of $0.1/W for residential and small non-residential systems, and effectively no change for large non-residential systems. These recent trends are generally consistent with the pace of price declines since 2014, and mark a slowing from the years immediately preceding (2009-2013) when prices fell by roughly $1/W per year. -Installed Prices Vary Widely Across Individual Projects. Among residential systems installed in 2017, 20% were priced below $3.0/W (the 20th percentile value) while another 20% were above the 80th percentile at $4.5/W. Non-residential systems also exhibit wide spreads, albeit shifted downward, from $2.4/W to $4.1/W for small non-residential and from $1.8/W to $2.8/W for large non-residential projects. These pricing spreads have persisted over time and are both reflective of the heterogeneity in PV systems and markets, as well as suggestive of the potential for further price declines. -Pronounced Pricing Disparities Exist Across States. State-level median installed prices in 2017 ranged from $2.6/W to $4.5/W for residential systems, from $2.2/W to $4.0/W for small non-residential systems, and from $2.1/W to $2.4/W for large non-residential systems. Three of the largest state markets (California, Massachusetts, and New York) are relatively high-priced, pulling overall U.S. median prices upward. These cross-state pricing differences reflect both idiosyncratic features of particular states as well as more-fundamental differences related to market and policy conditions. -Installed Pricing Variation Also Reflects Differences in System Design, Installer, and Customer Characteristics (among other factors). Significant pricing differences were also observed across system sizes within each customer segment (with median prices ranging from $3.2/W to $4.5/W across residential systems of varying size, and from $2.1/W to $3.7/W across non-residential systems), between third-party owned (TPO) and host-owned residential systems ($3.3/W vs. $3.8/W), across residential installers ($2.1/W to $9.6/W for host-owned systems and $1.1/W to $5.1/W for TPO systems), between residential new construction and retrofit systems in California ($2.3/W vs. $3.9/W), between large non-residential systems at commercial sites and tax-exempt customer sites ($2.1/W vs. $2.6/W), and between systems with standard vs. premium efficiency modules ($3.6/W vs. $4.2/W among residential systems). A public version of the underlying dataset can be downloaded at https://emp.lbl.gov/tracking-the-sun.

14 SOLAR ENERGY↗

Stasis PCM Test Results

A phase change material product distributed by Stasis Group, designed to reduce the cooling energy requirements of multi-story commercial buildings, was tested in a side-by-side comparison at FLEXLAB® (LBNL, 2018), a calibrated test facility for low energy building technology solutions. The product was installed according to Stasis recommendations in the ceiling plenum of a 600 ft 2 cell representative of an office space, while an identical cell was operated in the same conditions, except for the night-time pre-cooling sequence and without the product, to gather baseline data. The cells were operated to replicate summer conditions of a candidate office building for retrofit. For the tests conducted at FLEXLAB, two Phase Change Material (PCM) compositions were tested, with the second product having an upgraded composition for thermal performance and upgraded packaging that was used to meet with fire safety requirements for a plenum application. Two rounds of tests were performed, which were designed to collect data for both core (designated as Round 1) and perimeter (Round 2) office space conditions. Following the analysis of the data collected during Round 1, the experimental design was modified to better represent the thermal conditions of a typical office space in relation to the PCM performance. A new product was also brought in for testing in Round 2, which had an improved operational temperature range and packaging properties. In Round 1, multiple tests were conducted to evaluate the performance of the product under different conditions of internal loads, temperature setpoints, pre-cooling strategies and temperature control strategies. In Round 2, the internal conditions were kept constant, while the test conditions only differ in the amount of PCM installed in the test cell plenum and the length of the nighttime pre-cooling sequence. The performance benefits of PCM are generally two-fold: the material may reduce peak cooling energy use during daytime hours (a peak demand energy use benefit) and may allow for energy savings with pre-cooling at night through night flush HVAC controls when night time outside air temperatures are lower, and fan energy use for cooling is more efficient than the use of daytime compressor-based cooling. The focus of this research project was mainly on quantifying the energy savings potential of the latter case although some effects on peak reduction were noted. Between the cell with PCM and nighttime precooling and the reference cell without PCM or precooling, a reduction in cooling load during occupied hours was noted between 7.6 kWh (or 22% of occupied hours cooling load) and 12.5 kWh (or 33% of occupied pg. 7 hours cooling load). Future work can further evaluate the peak cooling load reduction benefits of this product in more detail. This report highlights the results of Round 2, which reflect the performance of the modified PCM product when operated in suitable conditions. The results of Round 1, along with an analysis of the experimental data to identify the factors that prevented the product from performing as desired are presented in Appendix B.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Report on the Economic Optimization of a Demonstration Case for a Static N-R HES Configuration using RAVEN

The synthetic time history generation algorithm in RAVEN has been extensively tested and used to perform qualitative assessments of the statistical characteristics of the net demand vs. demand for different values of the penetration of wind generation. Reported results highlight the need to consider the impact of variable renewable on the electricity net demand profile, due to the increase in its volatility with increased wind penetration. This analysis provides a strong foundation for the modeling and simulation needs expressed under the "Nuclear-Renewable Hybrid Energy Systems" (NRHES) project. Following this confirmative analysis the entire stochastic optimization framework has been tested in a demo case. The case chosen is an optimization driven by profitability for a system composed by a nuclear plant and a hydrogen production industrial process. This type of economical analysis is aimed to assess the capability of a hybrid system to penetrate the current energy market. In this sense it differs from the approach suggested under NRHES, where a cost minimization approach is suggested. This analysis is instead aimed to show the flexibility of the developed framework, e.g. for the evaluation of retrofitting projects of already existing plants. The system considered is subject to variable prices of electricity, which are simulated using the algorithm for the production of synthetic time histories. The physical system is considered without inertia so that it can be replaced by dispatching rules based on the highest marginal profit. Two optimization problems have been considered, for the first the size of the nuclear power plant is fixed and the optimization variable is the capacity of the hydrogen production plant. For the second, both plant sizes are optimization parameters while the overall capital expenditure is caped. The economical figures of merits considered are the Internal Rate of Return (IRR) and/or Profitability Index (PI) for the first one (since no cap is placed on the investment size) and Net Present Value (NPV) and/or IRR for the second one where the capital expenditure is constrained. Economic input data concerning capital costs, size-scaling factors, and operational costs for both plants have been collected from literature in order to achieve a simulation as realistic as possible. More work will be needed to obtain even more realistic numbers, possibly from industrial partners, and considering market elasticity for the hydrogen market. In order to perform the optimization of the cases described above, the economical external RAVEN module (CashFlow) for financial analysis has been improved in flexibility and generality. Some improvements have also been made to the optimization algorithm for a more efficient treatment of the boundary constrains. In conclusion three major results have been obtained: a) collection of the economical parameters characterizing the nuclear power plants and hydrogen production plants, b) extension of the financial analysis module (CashFlow) to drive the calculation of all needed cash flow streams and c) the testing of the full framework in a nearly final configuration.

97 MATHEMATICS AND COMPUTING↗

Lab-scale Development of a Hybrid Capture System with Advanced Membrane, Solvent system, and Process Integration

The objective of the project is to achieve lab-scale demonstration of a transformational hybrid membrane/solvent system for the capture of CO 2 from flue gas. A novel process integration scheme was proposed to overcome the low partial pressure of CO 2 present in flue gas. This scheme takes advantage of the potential synergies inherent in the membrane and solvent capture systems. The proposed hybrid technology replaces the second-stage membrane with a solvent capture process. The combustion air is used as a sweeping gas in the solvent stripper. This overall configuration has the major advantages of requiring much less air and eliminating the problems associated with oxygen slip in the membrane-based systems. Even more importantly, because of the presence of the air sweep in the stripper, much lower temperatures are required for solvent regeneration, which enables heat integration to the point that no process steam is required. This project was to perform lab-scale demonstration of Liquid Ion Solutions (LIS) transformational hybrid membrane/solvent system for post-combustion CO 2 capture while demonstrating significant progress toward achievement of the overall fossil energy performance goals of 90% CO 2 capture rate with 95% CO 2 purity at a cost of electricity 30% less than baseline capture approaches. This report is written chronologically based on budget periods. Each budget period discusses the work performed and its results. At the end of each budget period the milestone charts are provided to show the progress. This project was not able to meet its stated goals. The performances of the power plant equipped with the hybrid process and Baseline Case B12B were compared. The simulation results showed that the power plant equipped with hybrid CO2 capture process has an improved thermal efficiency of 33.4% compared to the Baseline Case B12B, which is 32.5%. However, the COE for the hybrid process is $146.3/MWh which is higher than the $142.8/MWh for Case B12B. If this process were to be applied as a retrofit, it may make sense to use this configuration as it does not require any change in an existing plant configuration and steam cycle. However, for a new powerplant the capital cost is higher than the Case B12B. On the membrane development side, we successfully showed that interfacially-controlled envelope (ICE) membranes work. The inclusion of surface modified nano-particles results in much higher gas diffusivities. The Gen-1 ICE membrane developed under this project showed exceptional improved permeability for CO 2 . However, we ran into major problems which were associated with the scalability and reproducibility of the poly(phosphozene) polymers. The issues with scale-up are and batch to batch variability is also discussed. At the end of this report we have provided our recommendations on materials development for better membrane materials and alluded to the use of much simpler chemistry while keeping the concept of ICE membrane intact. It is also clear that vacuum and compression equipment is costly. If a process which can eliminate the use of vacuum and compression equipment would significantly decrease the overall cost of capture. Some thoughts regarding such system is also provided in the outlook portion of this report.

20 FOSSIL-FUELED POWER PLANTS↗