Feed the fish: A review of aquaculture feeders and their strategic implementation

Automatic feeders are revolutionizing aquaculture by enabling precise and controlled feeding regimens that optimize growth, reduce feed waste, and enhance the overall efficiency of farming operations. Demand feeders provide some similar benefits but with feeding tailored to fish appetites and, in some cases, feed dispersal without electricity. This review explores the evolution, technological advancements, and applications of these feeders with a survey of recent research. It looks at common feeder designs and compares the pros and cons of five automatic feeder configurations in commercial use today. The article contrasts feeders and feed sizes for farmed species in different life stages and facilities, from hatcheries to ponds and offshore cages. It discusses the importance of species-tailored feeding strategies as well as impacts on fish behavior and health, nutrient delivery, and environmental sustainability. Incorporating sensors and on-site computing enables optimization in feeding algorithms that feeders then implement precisely and reliably. The review compiles results from multiple studies comparing growth rate, weight, and feed conversion ratio (FCR) outcomes from automatic feeders and demand feeders versus traditional hand-feeding regimens. The integration of feeders with real-time monitoring and data analytics is also discussed, highlighting future directions for research and adoption across the industry.

42 ENGINEERING↗

Large Language Model for Validation, Optical Calibration, and Learning (VOCAL) Distributed Temperature Sensing Interface

Distributed temperature sensing (DTS) using fiber optic sensors (FOS) offers a promising method for temperature measurements in advanced reactors, such as sodium fast reactors and molten salt cooled reactors. To support the calibration and validation of DTS measurements, Argonne National Laboratory developed the Validation, Optical Calibration, and Learning (VOCAL) software package. This report describes the integration of a local large language model (LLM) with a retrieval-augmented generation (RAG) system into the VOCAL interface to serve as an interactive user assistant. The LLM framework enhances the VOCAL platform’s accessibility to users by explaining interface components, clarifying inputs and outputs, and answering user queries dynamically in real-time. The accuracy of the LLM assistant performance was evaluated with 20 queries regarding the interface and its parameters using experimental data from the Thermal Hydraulic Experimental Test Article (THETA) facility. Results demonstrate that the LLM achieved a 95% accuracy rate, with a BERTScore of 0.8816 and SBERT value of 0.7417. Furthermore, validation of the RAG system within the LLM framework showed optimal accuracy with k-values between 1 and 2 using the k-refinement convergence test. The prompt perturbation analysis demonstrated good initial consistency for the RAG system, exhibiting the highest accuracy under punctuation variations and the greatest sensitivity under query reordering. Notably, the model’s errors were limited to data retrieval failures rather than factual hallucinations, reinforcing its baseline reliability. The integration of LLM provides a highly accurate, userfriendly enhancement to the VOCAL platform without disrupting its core computational capabilities for FOS calibration and validation.

Hong, Evan↗

Local Explosion Detection and Infrasound Localization by Reverse Time Migration Using 3-D Finite-Difference Wave Propagation

Infrasound data are routinely used to detect and locate volcanic and other explosions, using both arrays and single sensor networks. However, at local distances (< km) topography often complicates acoustic propagation, resulting in inaccurate acoustic travel times leading to biased source locations when assuming straight-line propagation. Here we present a new method, termed Reverse Time Migration-Finite-Difference Time Domain (RTM-FDTD), that integrates numerical modeling into the standard RTM back-projection process. Travel time information is computed across the entire potential source grid via FDTD modeling to incorporate the effects of topography. The waveforms are then back-projected and stacked at each grid point, with the stack maximum corresponding to the likely source. We apply our method to three volcanoes with different network configurations, source-receiver distances, and topography. At Yasur Volcano, Vanuatu, RTM-FDTD locates explosions within ~20 m of the source and differentiates between multiple vents. RTM-FDTD produces a more accurate location for the two Yasur subcraters than standard RTM and doubles the number of detected events. At Sakurajima Volcano, Japan, RTM-FDTD locates the source within 50 m of the active vent despite notable topographic blocking. The RTM-FDTD location is similar to that from the Time Reversal Mirror method, but is more computationally efficient. Lastly, at Shishaldin Volcano, Alaska, RTM and RTM-FDTD both produce realistic source locations (<50 m) for ground-coupled airwaves recorded on a four-station seismic network. We show that RTM is an effective method to detect and locate infrasonic sources across a variety of scenarios, and by integrating numerical modeling, RTM-FDTD produces more accurate source locations and increases the detection capability.

58 GEOSCIENCES↗

LaserSnake2: An Innovative Approach to Nuclear Decommissioning - 17080

Nuclear decommissioning challenges exist the world over and require innovative approaches to ensure safe and cost effective dismantling of high hazard nuclear facilities. LaserSnake technology makes use of the flexibility and dexterity of snake arm robots to deploy high-powered laser cutting, lifting and manipulation tools. This paper describes the development and use of the system to achieve the successful size reduction and removal of a substantial stainless steel vessel within the First Generation Reprocessing Plant (FGRP) at Sellafield in the UK. Due to the environment, nuclear decommissioning is an extremely challenging activity. High ambient radiation levels often preclude entry to the areas involved, and as industry tries to minimise dose uptake, even moderate radiation levels now require remote solutions. 'In-situ' size reduction of process plant, including vessels and pipework, will allow the removal of the nuclear inventory from a building prior to further decontamination and demolition. The term 'in situ' is in this case used to mean work done on plant items within their existing cells as opposed to moving items from their original location to a dedicated size reduction facility. Traditional size reduction cutting methods, such as reciprocating saws or grinders, pose a significant challenge for remote deployment platforms. This includes the loss of haptic feedback and the length of time taken to perform the task, and difficulty dealing with the reaction forces. Although remote engineered solutions for these tools are possible, they are are typically complicated, unreliable and expensive. Robot deployed laser cutting is widely used in non-nuclear industrial sectors, and offers a simpler method for size reduction. LaserSnake2 is a UK collaborative project, co-funded by the Nuclear Decommissioning Authority, Innovate UK and the Department of Energy and Climate Change. The project combined the skills of robotic experts and laser and optic specialists, to develop a remote handling technology suited for deployment within active nuclear environments. As well as meeting strict safety case requirements, the system provides a safe and cost effective method for decommissioning of complex nuclear spaces. An overview of the system development and deployment is presented in this paper. In July 2016, a successful decommissioning campaign was conducted in the FGRP at Sellafield. The LaserSnake2 system was used to size reduce a double-skinned dissolver vessel within a radiologically active nuclear cell. Planning of the size reduction method and processes, as well as results of the campaign itself are described in this paper. The containment procedures and radiological considerations for the system are presented along with the effects of operations on the cell and ventilation systems. LaserSnake, developed as a modular arm system with up to 4.5 m of articulation, carries an integrated tool comprising a high power, decommissioning specific, laser cutting head, high definition cameras and high powered illumination LEDs. It is designed for precise dismantling work within confined and hazardous environments. The tool can be interchanged, allowing the snake-arm robot also to carry grippers, environmental mapping sensors and other tools which may prove advantageous during a decommissioning campaign. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Imaging of moving fiducial markers during radiotherapy using a fast, efficient active pixel sensor based EPID

Purpose: The purpose of this work was to investigate the use of an experimental complementary metal-oxide-semiconductor (CMOS) active pixel sensor (APS) for tracking of moving fiducial markers during radiotherapy. Methods: The APS has an active area of 5.4 x 5.4 cm and maximum full frame read-out rate of 20 frame s{sup -1}, with the option to read out a region-of-interest (ROI) at an increased rate. It was coupled to a 4 mm thick ZnWO4 scintillator which provided a quantum efficiency (QE) of 8% for a 6 MV x-ray treatment beam. The APS was compared with a standard iViewGT flat panel amorphous Silicon (a-Si) electronic portal imaging device (EPID), with a QE of 0.34% and a frame-rate of 2.5 frame s{sup -1}. To investigate the ability of the two systems to image markers, four gold cylinders of length 8 mm and diameter 0.8, 1.2, 1.6, and 2 mm were placed on a motion-platform. Images of the stationary markers were acquired using the APS at a frame-rate of 20 frame s{sup -1}, and a dose-rate of 143 MU min{sup -1} to avoid saturation. EPID images were acquired at the maximum frame-rate of 2.5 frame s{sup -1}, and a reduced dose-rate of 19 MU min{sup -1} to provide a similar dose per frame to the APS. Signal-to-noise ratio (SNR) of the background signal and contrast-to-noise ratio (CNR) of the marker signal relative to the background were evaluated for both imagers at doses of 0.125 to 2 MU. Results: Image quality and marker visibility was found to be greater in the APS with SNR {approx}5 times greater than in the EPID and CNR up to an order of magnitude greater for all four markers. To investigate the ability to image and track moving markers the motion-platform was moved to simulate a breathing cycle with period 6 s, amplitude 20 mm and maximum speed 13.2 mm s{sup -1}. At the minimum integration time of 50 ms a tracking algorithm applied to the APS data found all four markers with a success rate of {>=}92% and positional error {<=}90 {mu}m. At an integration time of 400 ms the smallest marker became difficult to detect when moving. The detection of moving markers using the a-Si EPID was difficult even at the maximum dose-rate of 592 MU min{sup -1} due to the lower QE and longer integration time of 400 ms. Conclusions: This work demonstrates that a fast read-out, high QE APS may be useful in the tracking of moving fiducial markers during radiotherapy. Further study is required to investigate the tracking of markers moving in 3D in a treatment beam attenuated by moving patient anatomy. This will require a larger sensor with ROI read-out to maintain speed and a manageable data-rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarization of gold in nanopores leads to ion current rectification

Biomimetic nanopores with rectifying properties are relevant components of ionic switches, ionic circuits, and biological sensors. Rectification indicates that currents for voltages of one polarity are higher than currents for voltages of the opposite polarity. Ion current rectification requires the presence of surface charges on the pore walls, achieved either by the attachment of charged groups or in multielectrode systems by applying voltage to integrated gate electrodes. Here we present a simpler concept for introducing surface charges via polarization of a thin layer of Au present at one entrance of a silicon nitride nanopore. In an electric field applied by two electrodes placed in bulk solution on both sides of the membrane, the Au layer polarizes such that excess positive charge locally concentrates at one end and negative charge concentrates at the other end. Consequently, a junction is formed between zones with enhanced anion and cation concentrations in the solution adjacent to the Au layer. This bipolar double layer together with enhanced cation concentration in a negatively charged silicon nitride nanopore leads to voltage-controlled surface-charge patterns and ion current rectification. The experimental findings are supported by numerical modeling that confirm modulation of ionic concentrations by the Au layer and ion current rectification even in low-aspect ratio nanopores. Lastly, our findings enable a new strategy for creating ionic circuits with diodes and transistors.

36 MATERIALS SCIENCE↗

First measurements of D{sub α} spectrum produced by anisotropic fast ions in the gas dynamic trap

Angled injection of eight deuterium beams in gas dynamic trap (GDT) plasmas builds up the population of fast ions with the distribution function, which conserves a high degree of initial anisotropy in space, energy, and pitch angle. Unlike the Maxwellian distribution case, the fast ion plasma component in GDT cannot be exhaustively characterized by the temperature and density. The instrumentation complex to study of fast ions is comprised of motional Stark effect diagnostic, analyzers of charge exchange atoms, and others. The set of numerical codes using for equilibrium modeling is also an important tool of analysis. In the recent campaign of summer 2014, we recorded first signals from the new fast ion D-alpha diagnostic on GDT. This paper presents the diagnostic description and results of pilot measurements. The diagnostic has four lines of sight, distributed across the radius of an axially symmetric plasma column in GDT. In the present setup, a line-integrated optical signal is measured in each channel. In the transverse direction, the spatial resolution is 18 mm. Collected light comes to the grating spectrometer with the low-noise detector based on a charge-coupled device matrix. In the regime of four spectra stacked vertically on the sensor, the effective spectral resolution of measurements is approximately 0.015 nm. Exposure timing is provided by the fast optical ferroelectric crystal shutter, allowing frames of duration down to 70 μs. This number represents the time resolution of measurements. A large dynamic range of the camera permits for a measurement of relatively small light signals produced by fast ions on top of the bright background emission from the bulk plasma. The fast ion emission has a non-Gaussian spectrum featuring the characteristic width of approximately 4 nm, which can be separated from relatively narrow Gaussian lines of D-alpha and H-alpha coming from the plasma periphery, and diagnostic beam emission. The signal to noise ratio varies from approximately ten for the central channel to approximately five for the outermost channel. We used the special set of Monte Carlo codes to fit the measured spectra. The shape of model fit shows a good agreement with the experimental fast ion D-alpha spectrum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technical Readiness and Gaps Analysis of Commercial Optical Materials and Measurement Systems for Advanced Small Modular Reactors

This report intends to support Department of Energy’s Office of Nuclear Energy (DOE-NE) Nuclear Energy Research and Development Roadmap and industry stakeholders by evaluating optical-based instrumentation and control (I&C) concepts for advanced small modular reactor (AdvSMR) applications. These advanced designs will require innovative thinking in terms of engineering approaches, materials integration, and I&C concepts to realize their eventual viability and deployability. The primary goals of this report include: 1. Establish preliminary I&C needs, performance requirements, and possible gaps for AdvSMR designs based on best available published design data. 2. Document commercial off-the-shelf (COTS) optical sensors, components, and materials in terms of their technical readiness to support essential AdvSMR in-vessel I&C systems. 3. Identify technology gaps by comparing the in-vessel monitoring requirements and environmental constraints to COTS optical sensor and materials performance specifications. 4. Outline a future research, development, and demonstration (RD&D) program plan that addresses these gaps and develops optical-based I&C systems that enhance the viability of future AdvSMR designs. The development of clean, affordable, safe, and proliferation-resistant nuclear power is a key goal that is documented in the Nuclear Energy Research and Development Roadmap. This roadmap outlines RD&D activities intended to overcome technical, economic, and other barriers, which currently limit advances in nuclear energy. These activities will ensure that nuclear energy remains a viable component to this nation’s energy security.

advanced small modular reactors↗

Demonstration and Evaluation of a Non-Invasive, Low-Cost, Strap-On Sensor for Natural Gas Meters

The U.S. General Services Administration (GSA) is interested in installing internet-connected, gas submeters to better understand gas consumption in its portfolio of buildings. The GSA in partnership with the National Renewable Energy Laboratory conducted a demonstration to assess a specific submeter technology. This technology was implemented at two GSA separate facilities located in Dallas, Texas. This demonstration evaluated hardware and software installations and integrations, data integrity and accuracy, and included an economic analysis. This demonstration evaluated a gas submeter technology provided by the vendor Vata Verks, who produces a non-invasive strap-on submeter. The company was founded with a mission to conserve water (and eventually gas) cheaply and simply, as explained on its website. The product intends to streamline submeter deployments for gas and water by eliminating most hardware costs while allowing for easy integration of submetered data into other systems such as the Building Automation System and removing tenant and building disruption This demonstration evaluated the product features when used on a gas utility meter.

03 NATURAL GAS↗

Internet of Things (IoT) Products and Applications: Lighting - Manufacturer and End-User Perspectives

It is forecast that the Internet of Things (IoT) market will experience significant growth in the coming years, with many expecting compound annual growth rates generally in the mid-20% (Forbes 2017). For lighting manufacturers, this is a tremendous opportunity to revolutionize their products to address the dwindling sales of lamps, once a major revenue stream, and bring new capabilities and services to their customers through luminaires and other lighting system components. For end-users, lighting products of the future may do more than simply provide light, with a cadre of connected sensors and controls that may help them do everything from exploring energy saving opportunities in other building systems to data-mining occupancy data to optimize use of space or increase sales. The focus of this study is to evaluate where the lighting market is today with respect to integrating IoT into its product offerings and end-user experiences with IoT, and in particular with IoT incorporated into lighting systems. The benefits, in terms of energy savings, of encouraging the adoption of connected lighting systems beyond the current solid state lighting (SSL) path to more aggressive DOE SSL Program Goals can result in an additional 33-percent of the LED energy savings, or 1.4 Quads, in 2035 (Navigant 2016).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Arctic as a test case for an assessment of climate impacts on national security.

The Arctic region is rapidly changing in a way that will affect the rest of the world. Parts of Alaska, western Canada, and Siberia are currently warming at twice the global rate. This warming trend is accelerating permafrost deterioration, coastal erosion, snow and ice loss, and other changes that are a direct consequence of climate change. Climatologists have long understood that changes in the Arctic would be faster and more intense than elsewhere on the planet, but the degree and speed of the changes were underestimated compared to recent observations. Policy makers have not yet had time to examine the latest evidence or appreciate the nature of the consequences. Thus, the abruptness and severity of an unfolding Arctic climate crisis has not been incorporated into long-range planning. The purpose of this report is to briefly review the physical basis for global climate change and Arctic amplification, summarize the ongoing observations, discuss the potential consequences, explain the need for an objective risk assessment, develop scenarios for future change, review existing modeling capabilities and the need for better regional models, and finally to make recommendations for Sandia's future role in preparing our leaders to deal with impacts of Arctic climate change on national security. Accurate and credible regional-scale climate models are still several years in the future, and those models are essential for estimating climate impacts around the globe. This study demonstrates how a scenario-based method may be used to give insights into climate impacts on a regional scale and possible mitigation. Because of our experience in the Arctic and widespread recognition of the Arctic's importance in the Earth climate system we chose the Arctic as a test case for an assessment of climate impacts on national security. Sandia can make a swift and significant contribution by applying modeling and simulation tools with internal collaborations as well as with outside organizations. Because changes in the Arctic environment are happening so rapidly, a successful program will be one that can adapt very quickly to new information as it becomes available, and can provide decision makers with projections on the 1-5 year time scale over which the most disruptive, high-consequence changes are likely to occur. The greatest short-term impact would be to initiate exploratory simulations to discover new emergent and robust phenomena associated with one or more of the following changing systems: Arctic hydrological cycle, sea ice extent, ocean and atmospheric circulation, permafrost deterioration, carbon mobilization, Greenland ice sheet stability, and coastal erosion. Sandia can also contribute to new technology solutions for improved observations in the Arctic, which is currently a data-sparse region. Sensitivity analyses have the potential to identify thresholds which would enable the collaborative development of 'early warning' sensor systems to seek predicted phenomena that might be precursory to major, high-consequence changes. Much of this work will require improved regional climate models and advanced computing capabilities. Socio-economic modeling tools can help define human and national security consequences. Formal uncertainty quantification must be an integral part of any results that emerge from this work.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Optimization of an enclosed gas analyzer sampling system for measuring eddy covariance fluxes of H 2 O and CO 2

Several initiatives are currently emerging to observe the exchange of energy and matter between the earth's surface and atmosphere standardized over larger space and time domains. For example, the National Ecological Observatory Network (NEON) and the Integrated Carbon Observing System (ICOS) are set to provide the ability of unbiased ecological inference across ecoclimatic zones and decades by deploying highly scalable and robust instruments and data processing. In the construction of these observatories, enclosed infrared gas analyzers are widely employed for eddy covariance applications. While these sensors represent a substantial improvement compared to their open- and closed-path predecessors, remaining high-frequency attenuation varies with site properties and gas sampling systems, and requires correction. Here, we show that components of the gas sampling system can substantially contribute to such high-frequency attenuation, but their effects can be significantly reduced by careful system design. From laboratory tests we determine the frequency at which signal attenuation reaches 50 % for individual parts of the gas sampling system. For different models of rain caps and particulate filters, this frequency falls into ranges of 2.5–16.5 Hz for CO 2 , 2.4–14.3 Hz for H 2 O, and 8.3–21.8 Hz for CO 2 , 1.4–19.9 Hz for H 2 O, respectively. A short and thin stainless steel intake tube was found to not limit frequency response, with 50 % attenuation occurring at frequencies well above 10 Hz for both H 2 O and CO 2 . From field tests we found that heating the intake tube and particulate filter continuously with 4 W was effective, and reduced the occurrence of problematic relative humidity levels (RH > 60 %) by 50 % in the infrared gas analyzer cell. No further improvement of H 2 O frequency response was found for heating in excess of 4 W. These laboratory and field tests were reconciled using resistor–capacitor theory, and NEON's final gas sampling system was developed on this basis. The design consists of the stainless steel intake tube, a pleated mesh particulate filter and a low-volume rain cap in combination with 4 W of heating and insulation. In comparison to the original design, this reduced the high-frequency attenuation for H 2 O by ≈ 3/4, and the remaining cospectral correction did not exceed 3 %, even at high relative humidity (95 %). The standardized design can be used across a wide range of ecoclimates and site layouts, and maximizes practicability due to minimal flow resistance and maintenance needs. Lastly, due to minimal high-frequency spectral loss, it supports the routine application of adaptive correction procedures, and enables largely automated data processing across sites.

54 ENVIRONMENTAL SCIENCES↗

Ambient field seismology in critical zone hydrological sciences

Passive ambient noise monitoring is an emerging tool in environmental seismology, leveraging the ambient seismic field to assess temporal variations in shallow subsurface properties. This review focuses on the potential and challenges of using scattered coda waves from noise correlation functions to monitor critical zone dynamics. The sensitivity of seismic velocities to various environmental factors, including precipitation, snowmelt, atmospheric pressure, and groundwater fluctuations, underscores the method’s versatility. While coda waves excel in detecting subtle changes due to their scattered nature, ballistic waves provide higher spatial resolution, albeit with challenges in source stability. Advances in seismic sensing, including distributed acoustic sensing and low-cost geophone networks, have enabled high-resolution monitoring of hydrological processes, subsurface deformation, and seismic hazards. Integrating seismic data with hydrological models provides insights into water storage, pore pressure changes, and soil moisture dynamics. However, limitations in spatial resolution, calibration with ground truth data, and coupled effects between environmental factors remain key challenges. This review emphasizes the importance of interdisciplinary approaches in refining methodologies, enhancing sensor deployments, and addressing data gaps. Passive seismic monitoring offers opportunities to understand critical zone processes and their broader impacts on seismic hazards and environmental sustainability.

58 GEOSCIENCES↗

Hydrogen Detection Strategies to Support H2@SCALE - The NREL Sensor Laboratory

Hydrogen represents a major pathway to decarbonize and stabilize the national and international energy industry and select manufacturing markets. To facilitate the development of hydrogen markets, the US Department of Energy initiated H2@Scale to bring together stakeholders to advance affordable hydrogen production, transport, storage, and utilization to increase revenue opportunities in multiple energy sectors. One major impediment to hydrogen implementation is cost. To expedite the use of hydrogen in energy and other markets, the United States announced in 2021 the Hydrogen Shot, which seeks to reduce the cost of clean hydrogen by 80% to $1 per 1 kilogram in 1 decade ("1 1 1"). As the cost of hydrogen drops, new applications will emerge that will require unique configurations of existing equipment and infrastructure, and eventually lead to advances in the generation and utilization of hydrogen. As the hydrogen economy expands, sensors and detection methods will need to adapt to changing infrastructure demands to address the primary targets of health & safety, emissions monitoring, and process control. The NREL Sensor Laboratory is playing a pivotal role in advancing the use of hydrogen sensors and detection methodologies in each of these categories to support DOE's mission for safe and efficient utilization in emerging markets. Health & safety monitors are required to ensure that operators and facilities can react to unintended hydrogen releases, either as GH2, LH2, or as a constituent of blends (e.g., natural gas or ammonia). Current detection methodologies focus on safety applications to detect near its lower flammable limit (4 vol %), and typically include point sensors in applications such as fixed or mobile detectors (e.g., personal gas monitors). Methodologies amenable for area detection include acoustic, emerging optical imaging methods, and flame detectors. Comparable detection strategies can be utilized for emissions monitoring and quantization, however few methods can simultaneously cover both low (emissions) and high (health & safety) levels. Deployment of emission level detectors will be required to 1) reduce product loss through small but potentially significant leaks from an environmental or cost perspective, 2) reduce downtime of high demand systems by early identification of eminent system failures (leaks through pump or compressor seals indicative of impending failure), and 3) address potential emission monitoring requirements that may be set by regulating bodies. The first two points should be adopted by industry to reduce the cost-of-goods-sold. The third main category for hydrogen detection relates to process control and may be advantageous for many existing applications. Two main applications are emerging. For example, the purity requirements for hydrogen that is dispensed from refueling systems for hydrogen fuel cell electric vehicles (FCEV) is rigorously regulated by the Standard SAE J2719, which prescribes maximum allowable levels of multiple impurities in the hydrogen fuel and must be verified by a regulatory body. Hydrogen contaminant detectors (HCD) integrated to the fueling station can assure this compliance. HCDs must be able operate in 100% H2 backgrounds and be able to distinguish between multiple contaminants at low ppm to low ppb levels. Secondly, as a strategy to decarbonize the natural gas grid, there are proposals to blend hydrogen with natural gas. This blending will affect transport applications (pipeline infrastructure), stationary combustion systems (turbines), and consumer and commercial appliances. In the short-term, hydrogen levels up to 20% are proposed. Variations in the hydrogen level can have dramatic impact on the combustion process and on the potential response of safety sensors. These mixtures may be regulated so that the concentration at a delivery point must be monitored with high precision. However, routine maintenance may introduce background gases such as ambient air (with water) or maintenance gases (introduced with welding processes or adhesive outgassing.) Therefore, the detection methodology must be robust enough to recover or respond to various contaminants. Several reviews can be found in literature addressing sensing and detection technologies, including their limitations and applications. However, for most applications, limitations can be alleviated by combining various detection techniques either through system integration or implementation of machine learning methods (artificial intelligence). In this presentation, we will discuss several applications, highlight their current approach for hydrogen detection, and suggest detection strategies to supplement their limitations.

ENERGY STORAGE,HYDROGEN↗

Quantum dot-based microfluidic biosensor for cancer detection

We report results of the studies relating to fabrication of an impedimetric microfluidic–based nucleic acid sensor for quantification of DNA sequences specific to chronic myelogenous leukemia (CML). The sensor chip is prepared by patterning an indium–tin–oxide (ITO) coated glass substrate via wet chemical etching method followed by sealing with polydimethylsiloxane (PDMS) microchannel for fluid control. The fabricated microfluidic chip comprising of a patterned ITO substrate is modified by depositing cadmium selenide quantum dots (QCdSe) via Langmuir–Blodgett technique. Further, the QCdSe surface has been functionalized with specific DNA probe for CML detection. The probe DNA functionalized QCdSe integrated miniaturized system has been used to monitor target complementary DNA concentration by measuring the interfacial charge transfer resistance via hybridization. The presence of complementary DNA in buffer solution significantly results in decreased electro-conductivity of the interface due to presence of a charge barrier for transport of the redox probe ions. The microfluidic DNA biosensor exhibits improved linearity in the concentration range of 10{sup −15} M to 10{sup −11} M.

60 APPLIED LIFE SCIENCES↗

Conformable amplified lead zirconate titanate sensors with enhanced piezoelectric response for cutaneous pressure monitoring

The ability to measure subtle changes in arterial pressure using devices mounted on the skin can be valuable for monitoring vital signs in emergency care, detecting the early onset of cardiovascular disease and continuously assessing health status. Conventional technologies are well suited for use in traditional clinical settings, but cannot be easily adapted for sustained use during daily activities. Here we introduce a conformal device that avoids these limitations. Ultrathin inorganic piezoelectric and semiconductor materials on elastomer substrates enable amplified, low hysteresis measurements of pressure on the skin, with high levels of sensitivity (~0.005 Pa) and fast response times (~0.1 ms). Experimental and theoretical studies reveal enhanced piezoelectric responses in lead zirconate titanate that follow from integration on soft supports as well as engineering behaviours of the associated devices. As a result, calibrated measurements of pressure variations of blood flow in near-surface arteries demonstrate capabilities for measuring radial artery augmentation index and pulse pressure velocity.

47 OTHER INSTRUMENTATION↗

In Situ Monitoring of Groundwater Contamination for Sustainable Remediation Using the Kalman Filter - 18423

Groundwater monitoring is critical for nuclear-related facilities as well as radioactively contaminated sites. Recent advances in sensing, data analytics and simulation capabilities provide substantial opportunities to improve and change current monitoring procedures. In particular, we need a paradigm shift from contaminant-only or compliance-only monitoring programs to comprehensive monitoring, i.e., including other ancillary environmental variables for a holistic understanding of the groundwater systems and plume behaviors. Such new approaches are needed for the effective implementation of sustainable remediation (enhanced and natural attenuation), and they have great potential for cost reduction in site monitoring. This paper reviews recent developments for improving long-term monitoring, with focus on the effective use of in situ sensors, data analytics and simulation capabilities. In particular, we highlight a recent application of the Kalman filter algorithm to estimate contaminant concentrations continuously in real time, based on in-situ measured water quality parameters (e.g. electrical conductance and pH) and sparse groundwater sampling. The results show that we can reduce the groundwater sampling frequency significantly, while capturing the dynamics of short- and long-term contaminant concentration changes. Such advanced and integrated monitoring systems will be beneficial for local residents (e.g., to ensure the safety by detecting adverse events early, enabling a swift response) as well as for site operators (e.g., to gain/improve public acceptance, to be better prepared for litigations and false claims, and to reduce overall monitoring cost). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a lab-scale, high-resolution, tube-generated X-ray computed-tomography system for three-dimensional (3D) materials characterization

The design and construction of a modular high resolution X-ray computed tomography (XCT) system is highlighted in this paper. The design approach is detailed for meeting a specified set of instrument performance goals tailored towards experimental versatility and high resolution imaging. The XCT tool is unique in the detector and X-ray source design configuration, enabling control in the balance between detection efficiency and spatial resolution. The system package is also unique: The sample manipulation approach implemented enables a wide gamut of in situ experimentation to analyze structure evolution under applied stimulus, by optimizing scan conditions through a high degree of controllability. The component selection and design process is detailed: Incorporated components are specified, custom designs are shared, and the approach for their integration into a fully functional XCT scanner is provided. Custom designs discussed include the dual-target X-ray source cradle which maintains position and trajectory of the beam between the two X-ray target configurations with respect to a scintillator mounting and positioning assembly and the imaging sensor, as well as a novel large-format X-ray detector with enhanced adaptability. The instrument is discussed from an operational point of view, including the details of data acquisition and processing implemented for 3D imaging via micro-CT. The performance of the instrument is demonstrated on a silica-glass particle/hydroxyl-terminated-polybutadiene (HTPB) matrix binder PBX simulant. Post-scan data processing, specifically segmentation of the sample's relevant microstructure from the 3D reconstruction, is provided to demonstrate the utility of the instrument. - Highlights: • Custom built X-ray tomography system for microstructural characterization • Detector design for maximizing polychromatic X-ray detection efficiency • X-ray design offered for maximizing X-ray flux with respect to imaging resolution • Novel lab-scale XCT data acquisition and data processing methods • 3D characterization of glass-bead mock plastic-bonded-explosive stimulant.