Search NASA⌕ Search

SEARCH · Search NASA

Results for “Software testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Dissertation Proposal: Innovations in Pulsed Power and Plasma Science Theory Simulation and Experiment

Pulsed power and plasma physics are topics of great study at both Sandia National Laboratories (SNL or Sandia) and the University of New Mexico (UNM). The goal of this research is to further knowledge and understanding of these fields using the resources of both SNL and UNM in three ways. The first way is through the comprehension, application, and testing of theory. Reading and analytically deriving theoretical solutions of problems both real-world and simplified will allow for a fresh perspective and the furthering of the theory. One such theory is Ottinger's generalized theory for voltage measurement in magnetically insulated transmission lines (MITLs). By working through the math, a deeper understanding of the theory is gained from which one may add more physically accurate and/or more detailed physics into the theory. Additionally, understanding the theory lays a good foundation from which one can analyze, test, and compare results to the theory in the following two ways that will advance the fields of pulsed power and plasma physics. The second way is through the modeling and simulation of real-world and simplified problems that utilize and test the afore mentioned theories. Theory can be applied to a simulation domain by using the unstructured time-domain electromagnetic (UTDEM) codes EMPHASIS and EMPIRE as well as the physical modeling software CUBIT, all of which were developed at SNL. Problems such as the modeling and design of the extended MITL on HERMES III, the understanding of space-charge-limited emission from vacuum cathodes, and the interaction between a relativistic electron beam and an ideal gas can all be modeled, simulated, and analyzed with this set of codes. Here the advantage is three-fold. Firstly, theory that describes our understanding of these problems can be put to the test and advanced through iterative simulation and analysis. Secondly, the understanding of these problems will have a positive impact on national security through the advancement of the technological capability of the United States of America. Thirdly, and not unrelated to the prior advantage, is the validation and verification of EMPIRE and EMPHASIS. This segues into the third way, which is through experiment and the comparison of experiment to simulated and theoretical results. Performing experimental comparisons completes the scientific method and grounds all of the work in reality. Being able to physically test theory and simulation is necessary for any real conclusions to be drawn. Another advantage for carrying out experimental work is to advance the physical testing capabilities of SNL. Several systems will be developed and tested through the course of this work that positively impact technological advancement of Sandia National Labs. Lastly, all of the above work will converge to yield a well-rounded perspective that ties the three categories of research together.

42 ENGINEERING↗

DETECTION OF FAST TRANSIENTS WITH RADIO INTERFEROMETRIC ARRAYS

Next-generation radio arrays, including the Square Kilometre Array (SKA) and its pathfinders, will open up new avenues for exciting transient science at radio wavelengths. Their innovative designs, comprising a large number of small elements, pose several challenges in digital processing and optimal observing strategies. The Giant Metre-wave Radio Telescope (GMRT) presents an excellent test-bed for developing and validating suitable observing modes and strategies for transient experiments with future arrays. Here we describe the first phase of the ongoing development of a transient detection system for GMRT that is planned to eventually function in a commensal mode with other observing programs. It capitalizes on the GMRT's interferometric and sub-array capabilities, and the versatility of a new software backend. We outline considerations in the plan and design of transient exploration programs with interferometric arrays, and describe a pilot survey that was undertaken to aid in the development of algorithms and associated analysis software. This survey was conducted at 325 and 610 MHz, and covered 360 deg{sup 2} of the sky with short dwell times. It provides large volumes of real data that can be used to test the efficacies of various algorithms and observing strategies applicable for transient detection. We present examples that illustrate the methodologies of detecting short-duration transients, including the use of sub-arrays for higher resilience to spurious events of terrestrial origin, localization of candidate events via imaging, and the use of a phased array for improved signal detection and confirmation. In addition to demonstrating applications of interferometric arrays for fast transient exploration, our efforts mark important steps in the roadmap toward SKA-era science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photoelectrochemically Self Improving Si/GaN Photocathode: Figure 3f Raw Data

XPS of Si/GaN photocathode after 10 hour chronoamperometry (CA) testing. Surface chemical composition and valence band structure of GaN were obtained by X-ray photoemission spectroscopy (XPS) on a Kratos Axis Ultra DLD system at a takeoff angle of 0° relative to the surface normal. An Al Kα source (hν = 1486.6 eV) was used to excite the core level electrons. Pass energy of 20 eV was used for the narrow scan of core levels and valence band spectra, and step size of 0.05 eV and 0.025 eV, respectively. The Spectral fitting was conducted using CasaXPS analysis software. The binding energy scales of all core levels were corrected to the N 1s of Ga – N bond at 397.8 eV. XPS O1s core level spectra from 10 hours CA tested Si/GaN sample, and deconvolution shows O - Ga bond, O - N - Ga bond and OH - H2O bond.

photocathode↗

Photoelectrochemically Self Improving Si/GaN Photocathode: Figure 3e Raw Data

XPS of Si/GaN photocathode after 4 hour chronoamperometry (CA) testing. Surface chemical composition and valence band structure of GaN were obtained by X-ray photoemission spectroscopy (XPS) on a Kratos Axis Ultra DLD system at a takeoff angle of 0° relative to the surface normal. An Al Kα source (hν = 1486.6 eV) was used to excite the core level electrons. Pass energy of 20 eV was used for the narrow scan of core levels and valence band spectra, and step size of 0.05 eV and 0.025 eV, respectively. The Spectral fitting was conducted using CasaXPS analysis software. The binding energy scales of all core levels were corrected to the N 1s of Ga – N bond at 397.8 eV. XPS O1s core level spectra from 4 hour CA tested Si/GaN sample, and deconvolution shows O - Ga bond, O - N - Ga bond and OH - H2O bond.

photocathode↗

SU-E-T-126: Application of PIPSpro and EPID for Quality Assurance of Medical Accelerators

Purpose: The purpose is to study applying PIPSpro and EPID for routine quality assurance of medical accelerators. Methods: (1) The coincidence of Light field and radiation field: Placed the FC-2 phantom on the treatment couch at the 100cm SSD. Using jaw set 10×10 cm{sup 2} or 15×15 cm{sup 2} field. Verified that the light field aligns with the engraved squares on the phantom. Placed the Crosshair Marker phantom on the top of the FC-2 phantom with the cross-hair and spherical marker aligned to the center of the light field. Acquired images with EPID and the images should be exported preferably in DICOM format. Analyzed Follow the recommended procedures in the radiation light field module of PIPSpro software.(2)MLC QA:Set up the MLC phantom on the treatment couch at isocenter. Positioned the EPID imager at the highest possible position without colliding with either the couch or the phantom. Created and delivered four different patterns for testing the MLC leaf position, leaf width, multi-port and leaf transmission. (3)Radiation isocenter test: Included the isocenter of collimator rotation, gantry rotation and couch rotation. Set the jaws of the collimator to create a thin field as 0.4cm x 20cm.Irradiated film or EPID using an equidistant 15° spacing angles with rotating collimator, gantry and couch respectively. Results: We analyzed imagers from EPID and film with PIPSPro software. As a Result, we acquired the specifications of medical accelerators quickly. In the meantime, the results were saved to database for trending and future analysis. Conclusion: Quality assurance of medical accelerator is very important. We used PIPSpro and EPID for routine detection, not only improved our efficiency, but also saved the cost. It is an good method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Metabolic skinflint or spendthrift? Insights into ground sloth integument and thermophysiology revealed by biophysical modeling and clumped isotope paleothermometry

Abstract Remains of megatheres have been known since the 18th -century and were among the first megafaunal vertebrates to be studied. While several examples of preserved integument show a thick coverage of fur for smaller ground sloths living in cold climates such as Mylodon and Nothrotheriops , comparatively very little is known about megathere skin. Assuming a typical placental mammal metabolism, it was previously hypothesized that megatheres would have had little-to-no fur as they achieved giant body sizes. Here the “hairless model of integument” is tested using geochemical analyses to estimate body temperature to generate novel models of ground sloth metabolism, fur coverage, and paleoclimate with Niche Mapper software. The simulations assuming metabolic activity akin to those of modern xenarthrans suggest that sparse fur coverage would have resulted in cold stress across most latitudinal ranges inhabited by extinct ground sloths. Specifically, Eremotherium predominantly required dense 10 mm fur with implications for seasonal changes of coat depth in northernmost latitudes and sparse fur in the tropics; Megatherium required dense 30 mm fur year-round in its exclusive range of cooler, drier climates; Mylodon and Nothrotheriops required dense 10–50 mm fur to avoid thermal stress, matching the integument remains of both genera, and further implying the use of behavioral thermoregulation. Moreover, clumped isotope paleothermometry data from the preserved teeth of four genera of ground sloth yielded reconstructed body temperatures lower than those previously reported for large terrestrial mammals (29 ± 2°–32 ± 3° C). This combination of low metabolisms and thick fur allowed ground sloths to inhabit various environments.

Deak, Michael D.↗

The effect of self-consistent potentials on EXAFS analysis

A theory program intended for use with extended X-ray-absorption fine structure (EXAFS) spectroscopy and based on the popular FEFF8 is presented. It provides an application programming interface designed to make it easy to integrate high-quality theory into EXAFS analysis software. This new code is then used to examine the impact of self-consistent scattering potentials on EXAFS data analysis by methodical testing of theoretical fitting standards against a curated suite of measured EXAFS data. For each data set, the results of a fit are compared using a well characterized structural model and theoretical fitting standards computed both with and without self-consistent potentials. It is demonstrated that the use of self-consistent potentials has scant impact on the results of the EXAFS analysis.

Instruments & Instrumentation↗

LOCA simulation: analysis of rarefaction waves propagating through geometric singularities

The propagation of a transient wave through an orifice is investigated for applications to Loss Of Coolant Accident in nuclear plants. An analytical model is proposed for the response of an orifice plate and implemented in the EUROPLEXUS fast transient dynamics software. It includes an acoustic inertial effect in addition to a quasi-steady dissipation term. The model is experimentally validated on a test rig consisting in a single pipe filled with pressurized water. The test rig is designed to generate a rapid depressurization of the pipe, by means of a bursting disk. The proposed model gives results which compare favourably with experimental data. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Automatic tracking of arbitrarily shaped implanted markers in kilovoltage projection images: A feasibility study

Purpose: Certain types of commonly used fiducial markers take on irregular shapes upon implantation in soft tissue. This poses a challenge for methods that assume a predefined shape of markers when automatically tracking such markers in kilovoltage (kV) radiographs. The authors have developed a method of automatically tracking regularly and irregularly shaped markers using kV projection images and assessed its potential for detecting intrafractional target motion during rotational treatment. Methods: Template-based matching used a normalized cross-correlation with simplex minimization. Templates were created from computed tomography (CT) images for phantom studies and from end-expiration breath-hold planning CT for patient studies. The kV images were processed using a Sobel filter to enhance marker visibility. To correct for changes in intermarker relative positions between simulation and treatment that can introduce errors in automatic matching, marker offsets in three dimensions were manually determined from an approximately orthogonal pair of kV images. Two studies in anthropomorphic phantom were carried out, one using a gold cylindrical marker representing regular shape, another using a Visicoil marker representing irregular shape. Automatic matching of templates to cone beam CT (CBCT) projection images was performed to known marker positions in phantom. In patient data, automatic matching was compared to manual matching as an approximate ground truth. Positional discrepancy between automatic and manual matching of less than 2 mm was assumed as the criterion for successful tracking. Tracking success rates were examined in kV projection images from 22 CBCT scans of four pancreas, six gastroesophageal junction, and one lung cancer patients. Each patient had at least one irregularly shaped radiopaque marker implanted in or near the tumor. In addition, automatic tracking was tested in intrafraction kV images of three lung cancer patients with irregularly shaped markers during 11 volumetric modulated arc treatments. Purpose-built software developed at our institution was used to create marker templates and track the markers embedded in kV images. Results: Phantom studies showed mean ± standard deviation measurement uncertainty of automatic registration to be 0.14 ± 0.07 mm and 0.17 ± 0.08 mm for Visicoil and gold cylindrical markers, respectively. The mean success rate of automatic tracking with CBCT projections (11 frames per second, fps) of pancreas, gastroesophageal junction, and lung cancer patients was 100%, 99.1% (range 98%–100%), and 100%, respectively. With intrafraction images (approx. 0.2 fps) of lung cancer patients, the success rate was 98.2% (range 97%–100%), and 94.3% (range 93%–97%) using templates from 1.25 mm and 2.5 mm slice spacing CT scans, respectively. Correction of intermarker relative position was found to improve the success rate in two out of eight patients analyzed. Conclusions: The proposed method can track arbitrary marker shapes in kV images using templates generated from a breath-hold CT acquired at simulation. The studies indicate its feasibility for tracking tumor motion during rotational treatment. Investigation of the causes of misregistration suggests that its rate of incidence can be reduced with higher frequency of image acquisition, templates made from smaller CT slice spacing, and correction of changes in intermarker relative positions when they occur.

60 APPLIED LIFE SCIENCES↗

GlassForm

GlassForm is a software tool for generating preliminary waste glass formulas for a given waste stream. The software is useful because it reduces the number of verification melts required to develop a suitable additive composition. The software includes property models that calculate glass properties of interest from the chemical composition of the waste glass. The software includes property models for glass viscosity, electrical conductivity, glass transition temperature, and leach resistance as measured by the 7-day product consistency test (PCT).

Nelson, LeeO.↗

AmeriFlux FLUXNET-1F US-MN2 Morris: Corn-Soybean-Wheat with Cover Crops, Minimal Tillage

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-MN2 Morris: Corn-Soybean-Wheat with Cover Crops, Minimal Tillage. This is the FLUXNET version of the carbon flux data for the site US-MN2 Morris: Corn-Soybean-Wheat with Cover Crops, Minimal Tillage produced by applying the standard ONEFlux (1F) software. Site Description - Cropland, 3-year rotation (corn-soybean-wheat), cover crops (winter camelina and pennycress), minimum tillage, nutrient management by soil tests, uniform pest management, tile drainage

Helseth, Christina [USDA-ARS LTAR]↗

Integration of Advanced Probabilistic Analysis Techniques with Multi-Physics Models

An integrated simulation platform that couples probabilistic analysis-based tools with model-based simulation tools can provide valuable insights for reactive and proactive responses to plant operating conditions. The objective of this work is to demonstrate the benefits of a partial implementation of the Small Modular Reactor (SMR) Probabilistic Risk Assessment (PRA) Detailed Framework Specification through the coupling of advanced PRA capabilities and accurate multi-physics plant models. Coupling a probabilistic model with a multi-physics model will aid in design, operations, and safety by providing a more accurate understanding of plant behavior. This represents the first attempt at actually integrating these two types of analyses for a control system used for operations, on a faster than real-time basis. This report documents the development of the basic communication capability to exchange data with the probabilistic model using Reliability Workbench (RWB) and the multi-physics model using Dymola. The communication pathways from injecting a fault (i.e., failing a component) to the probabilistic and multi-physics models were successfully completed. This first version was tested with prototypic models represented in both RWB and Modelica. First, a simple event tree/fault tree (ET/FT) model was created to develop the software code to implement the communication capabilities between the dynamic-link library (dll) and RWB. A program, written in C#, successfully communicates faults to the probabilistic model through the dll. A systems model of the Advanced Liquid-Metal Reactor–Power Reactor Inherently Safe Module (ALMR-PRISM) design developed under another DOE project was upgraded using Dymola to include proper interfaces to allow data exchange with the control application (ConApp). A program, written in C+, successfully communicates faults to the multi-physics model. The results of the example simulation were successfully plotted.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Online Weld Quality Inspection System with Infrared Thermography

Today’s passenger vehicle on average contains 4,000 to 6,000 resistance spot welds (RSW). All US automakers perform destructive teardown evaluation to ensure the quality of the spot welds due to their criticality in crash resistance and performance of vehicles. The destructive teardown evaluation is labor intensive and costly. Sponsored by DOE VT Office, ORNL recently developed a prototype system (hardware and software) to non-destructively evaluate the quality of RSW based on infrared (IR) thermography. Highly cost competitive, ORNL’s system has been tested extensively in the laboratory with initial successful production environment validation. Ford, Honda, GM, Chrysler and major Tier One suppliers all have shown keen interest in this new technology. ORNL’s Technology Transfer Office licensed this technology to a small business (APLAIR Manufacturing Solutions) in TN. The licensee planned to develop a new hardware system based on ORNL’s IR NDE technology for real-time online weld inspection. In this CRADA project, ORNL was tasked to assist the licensee to transfer the technology and develop the new product suitable for automotive body-in-white production environment, making the technology ready for ‘real-world’ auto-body assembly line production environment.

47 OTHER INSTRUMENTATION↗

Software Requirements Document: Benchmarking Algorithm for RadioNuclide Identification (BARNI)

This document provides the requirements for the Benchmark Algorithm for Radio-Nuclide Identification (BARNI) software, an open-source tool for comparing radionuclide identification algorithm performance. It specifies the requirements for the user interface, maintainability, documentation and testing. In addition, this document outlines the core functionality of the product, which will align with the needs of the Office of Nuclear Smuggling Detection and Deterrence (NSDD). Specifically, these include interoperability with RASE, and compatibility with the FLIR R400.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Laser Wavelength Shift from Splitters and Switches

The Detonation Science and Technology Group (Q-6) operates several photon Doppler velocimetry (PDV) systems as a diagnostic tool for measuring velocities in the 1–10 km/s range during high explosive (HE) detonation experiments. Q-6 uses “heterodyne” PDV systems that are produced by Traverse Solutions and Instrumentation, LLC (TS&I). These heterodyne systems combine wavelength (WL) tunable source and “reference” lasers with a WL offset of 10–100 pm from each other. Properly setting the source and reference WLs for an experiment can be critical for collecting the desired experimental data. The tunable lasers report WL readings in their control software, but these readings are based on a lookup table from a temperature reading and are not able to be calibrated. Therefore, recent test fire programs that require PDV as a diagnostic have also implemented requirements for monitoring the WL of the tunable lasers using a precision WL meter. To monitor the WL of several PDV lasers without disconnecting any patch fibers form the experimental setup, Q-6 developed a system splitters with a coupling ratio (%) of 99:1 and an optical switch with the switch output going to a single WL meter. A brief experiment was developed to determine if the splitters and/or switch introduced any WL bias into the readings. The purpose of this report is to document the system, the experiment, and its results.

42 ENGINEERING↗

Advanced Grid Operational Technology Edge-Level Threat Detection

This report presents a deployable solution to improve the cybersecurity situational awareness of the legacy SCADA system infrastructure in power grids. The main goal of this project is to provide system owners and operators a highly trusted, intelligent alarm system and comprehensive situational awareness of ongoing or potential cybersecurity threats on the grid network. The key contributions of this project include: (1) the development of software, the Intrusion Detection Visualizer for the Operational Technology Network (IViz-OT), to visualize and locate intrusions on the grid network; (2) testing the signature-based Hybrid Intrusion Detection for Energy Systems (HIDES) for different types of intrusions; (3) the integration of HIDES and IViz-OT into the visualization dashboard; and (4) real-time testing using a hardware-in-the-loop test bed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

DOE Radiological Triage Program: Analyst Open Book Exam 2021

This document contains the open book exam for Radiological Triage Program Analysts for Los Alamos National Laboratory. "The following questions test your knowledge relevant to the DOE Radiological Triage program. There is no time limit, and you may use any reference materials or software you like. You may discuss with other analysts but please show your own work. Spectra are provided in electronic form. There are 10 questions and up to 1 point of extra credit is available. A score of 80% is required to pass. Please send your answers in any convenient form to Mercer@LANL.gov."

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Final Technical Report - Rapid Surface Microanalysis using a Low Temperature Plasma

This project focused on improving our current understanding and scientific knowledge in the area of plasma-surface interactions and plasma assisted material synthesis related to advanced microelectronics and nanotechnology. Current challenges include: controlling the interaction of Low Temperature Plasma (LTP) with a single layer of atoms to manufacture integrated circuits, continued miniaturization of integrated circuits, LTP processing of material surfaces and thin films to enable industrial scale fabrication of advanced microelectronics, synthesis of new materials, nanomaterials, nanotubes, and complex materials, Technology developed in this subtopic is of value to either (i) enable scans of surfaces (~1 sq. cm area) using various microscopies (electron, optical, other) at high resolution (micron or sub-micron resolution) rapidly (hours or days rather than years to complete a high-resolution scan of such a large surface area), or (ii) enable scans of surfaces (~1 sq. cm area) using various microscopies (electron, optical, other) at relatively low resolution rapidly, then apply algorithms to select spots for micron-scale imaging. Sputtering occurs when particles of a solid material are ejected from its surface by energetic particles from a plasma. While the degradation of the solid material and the subsequent deposition of the ejected material onto vulnerable surfaces are the usual subjects of sputtering studies, plasma science has yet to be combined with sputtering to create new diagnostics devices and systems. Small changes in the design of the plasma discharge device make it possible to create broad plasma beams for rapid scanning or small plasma beams to obtain the distribution of ejected elements with micron resolution. In the high-resolution use, the ion flux is extracted from the gas-discharge plasma and focused by a spherical emission surface to micron sizes onto the target specimen, providing very local sputtering and local elemental analysis. We call this “self-focusing”. The radiation from the excited and ionized sputtered atoms is recorded by a spectrometer through a window and fiberglass cable and analyzed with standard software packages used for optical glow discharge spectroscopy. Computer simulations of beam formation were used to verify and optimize the designs to be tested. A prototype was designed, constructed, and used to start experiments of beam formation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗