Search NASA⌕ Search

SEARCH · Search NASA

Results for “cavity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Adaptive machine learning for time-varying systems: low dimensional latent space tuning

Machine learning (ML) tools such as encoder-decoder convolutional neural networks (CNN) can represent incredibly complex nonlinear functions which map between combinations of images and scalars. For example, CNNs can be used to map combinations of accelerator parameters and images which are 2D projections of the 6D phase space distributions of charged particle beams as they are transported between various particle accelerator locations. Despite their strengths, applying ML to time-varying systems, or systems with shifting distributions, is an open problem, especially for large systems for which collecting new data for re-training is impractical or interrupts operations. Particle accelerators are one example of large time-varying systems for which collecting detailed training data requires lengthy dedicated beam measurements which may no longer be available during regular operations. We present a novel method of adaptive ML for time-varying systems. Our approach is to map very high (N ≈ 100k) dimensional inputs (a combination of scalar parameters and images) into the low dimensional (N ≈ 2) latent space at the output of the encoder section of an encoder-decoder CNN. We then actively tune the low dimensional latent space-based representation of complex system dynamics by the addition of an adaptively tuned feedback vector directly before the decoder sections builds back up to our image-based high-dimensional phase space density representations. This method allows us to learn correlations within and to quickly tune the characteristics of incredibly large parameter space systems and to track their evolution in real time based on feedback without massive new data sets for re-training. We demonstrate that our method can accurately predict and track the phase space of charged particle beams at various locations in a particle accelerator by adaptively adjusting in real-time while the unknown input beam distribution of the accelerator is changing in shape, charge, and offset and while the RF system of the accelerator itself is also changing in an unpredictable way. For FACET-II we demonstrate that such an approach has the potential to use transverse deflecting cavity and energy spread spectrum beam measurements to accurately predict 2D projections of the 6D phase space of the electron beam at the plasma wakefield acceleration interaction point where such diagnostics are unavailable.

47 OTHER INSTRUMENTATION↗

Using an Absolute Cavity Pyrgeometer to Calibrate Pyrgeometers Outdoors with Respect to the International System of Units

Accurate measurement of the atmospheric longwave irradiance is important for renewable energy and atmospheric science applications. Pyrgeometers are deployed outdoors all over the world to measure the atmospheric longwave irradiance and presently are calibrated with traceability to the interim standards for atmospheric longwave radiation measurement, the standards are based on four pyrgeometers and their average irradiance is the World InfraRed Standard Group (WISG) which is developed and maintained by The Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC). Since 2013 the InfraRed Integrating Sphere (IRIS) developed by PMOD/WRC and the Absolute Cavity Pyrgeometer (ACP) developed by the National Renewable Energy Laboratory (NREL) have been compared outdoors six times at different locations and the difference between the measured atmospheric longwave irradiance by ACP and IRIS was less than 2 W/m2 with traceability to the International System of Units (SI). During the six comparisons the irradiance measured by the interim WISG was 5 W/m2 lower than the irradiance measured by the average irradiance measured by the ACP and IRIS [1]. Based on this discrepancy, the World Meteorological Organization's Commission for Instruments and Methods of Observation (CIMO) recommended that the interim WISG should be adjusted to be traceable to SI units [2]. In anticipation of CIMO's expert team agreement on establishing the world reference using the average irradiance measured by ACP and IRIS in this article we describe a procedure to calibrate pyrgeometers with traceability to SI. One Absolute Cavity Pyrgeometer (ACP95F3) was used to calibrate four pyrgeometers traceable to SI units. Three Eppley PIRs and one Kipp&Zonen CG4 were originally calibrated with traceability to the interim WISG. Using the described procedure below, the responsivity of each pyrgeometer was then adjusted to match the irradiance measured by ACP. Outdoor data was collected during one clear sky nights monitored by the output thermopile voltage of ACP95F3. The irradiance measured by the PIRs was calculated using NREL equation and the CG4 using NREL equation and PMOD/WRC equation. Using the NREL equation, the calculated uncertainty (U_95) of the PIRs varied from 2.43 W/m2 to 2.67 W/m2, and for the CG4 using the NREL equation U_95 equals 1.97 W/m2, and using the PMOD equation U_95 equals 2.88 W/m2 with respect to SI.

International System of Units↗

Using an Absolute Cavity Pyrgeometer to Calibrate Pyrgeometers Outdoors with Respect to the International System of Units

Accurate measurement of the atmospheric longwave irradiance is important for renewable energy and atmospheric science applications. Pyrgeometers are deployed outdoors all over the world to measure the atmospheric longwave irradiance and presently are calibrated with traceability to the interim standards for atmospheric longwave radiation measurement, the standards are based on four pyrgeometers and their average irradiance is the World InfraRed Standard Group (WISG) which is developed and maintained by The Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC). Since 2013 the InfraRed Integrating Sphere (IRIS) developed by PMOD/WRC and the Absolute Cavity Pyrgeometer (ACP) developed by the National Renewable Energy Laboratory (NREL) have been compared outdoors six times at different locations and the difference between the measured atmospheric longwave irradiance by ACP and IRIS was less than 2 w/m2 with traceability to the International System of Units (SI). During the six comparisons the irradiance measured by the interim WISG was 5 w/m2 lower than the irradiance measured by the average irradiance measured by the ACP and IRIS [1]. Based on this discrepancy, the World Meteorological Organization's Commission for Instruments and Methods of Observation (CIMO) recommended that the interim WISG should be adjusted to be traceable to SI units [2]. In anticipation of CIMO's expert team agreement on establishing the world reference using the average irradiance measured by ACP and IRIS in this article we describe a procedure to calibrate pyrgeometers with traceability to SI. One Absolute Cavity Pyrgeometer (ACP95F3) was used to calibrate four pyrgeometers traceable to SI units. Three Eppley PIRs and one Kipp&Zonen CG4 were originally calibrated with traceability to the interim WISG. Using the described procedure below, the responsivity of each pyrgeometer was then adjusted to match the irradiance measured by ACP. Outdoor data was collected during one clear sky night monitored by the output thermopile voltage of ACP95F3. The irradiance measured by the PIRs and CG4 was calculated using NREL equation. The calculated uncertainty (U95) of the PIRs varied from 2.43 w/m2 to 2.67 w/m2 , and for the CG4 equals 1.97 w/m2 with respect to SI.

absolute cavity pyrgeometer↗

PLASMA TREATMENT OF BULK Nb SURFACE IN THE Ar/Cl2 DISCHARGE

The preparation of the cavity walls has been one of the major challenges in the superconducting radio-frequency (SRF) accelerator technology. Therefore, constant research and development effort is devoted to develop surface preparation processes that will improve roughness and lower the level of impurities, like hydrogen or oxygen, embedded in bulk Nb, having in the same time reasonable etching rates. Plasma based surface modification provides an excellent opportunity to achieve these goals. We present Ar/Cl2 discharge treatment of bulk Nb where we achieved etching rates comparable to the rates obtained with the electropolishing method without introducing impurities in Nb. The current experiments were performed on disk shaped Nb samples, exposed to plasma produced in a microwave discharge system. Surface composition and topology measurements were carried out before and after plasma treatment. Upon determining optimal experimental conditions on disk shaped samples, we will apply the same procedure on the single cell cavities, pursuing improvement of their RF performance.

08 HYDROGEN↗

Model Reduction for Compressible Cavity Simulations Towards Uncertainty Quantification of Structural Loading

This report summarizes FY16 progress towards enabling uncertainty quantification for compressible cavity simulations using model order reduction (MOR). The targeted application is the quantification of the captive-carry environment for the design and qualification of nuclear weapons systems. To accurately simulate this scenario, Large Eddy Simulations (LES) require very fine meshes and long run times, which lead to week-long runs even on parallel state-of-the-art super- computers. MOR can reduce substantially the CPU-time requirement for these simulations. We describe two approaches for model order reduction for nonlinear systems, which can yield significant speed-ups when combined with hyper-reduction: the Proper Orthogonal Decomposition (POD)/Galerkin approach and the POD/Least-Squares Petrov Galerkin (LSPG) approach. The implementation of these methods within the in-house compressible flow solver SPARC is discussed. Next, a method for stabilizing and enhancing low-dimensional reduced bases that was developed as a part of this project is detailed. This approach is based on a premise termed "minimal subspace rotation", and has the advantage of yielding ROMs that are more stable and accurate for long-time compressible cavity simulations. Numerical results for some laminar cavity problems aimed at gauging the viability of the proposed model reduction methodologies are presented and discussed.

42 ENGINEERING↗

NRG Oncology–Radiation Therapy Oncology Group Study 1014: 1-Year Toxicity Report From a Phase 2 Study of Repeat Breast-Preserving Surgery and 3-Dimensional Conformal Partial-Breast Reirradiation for In-Breast Recurrence

Purpose: To determine the associated toxicity, tolerance, and safety of partial-breast reirradiation. Methods and Materials: Eligibility criteria included in-breast recurrence occurring >1 year after whole-breast irradiation, <3 cm, unifocal, and resected with negative margins. Partial-breast reirradiation was targeted to the surgical cavity plus 1.5 cm; a prescription dose of 45 Gy in 1.5 Gy twice daily for 30 treatments was used. The primary objective was to evaluate the rate of grade ≥3 treatment-related skin, fibrosis, and/or breast pain adverse events (AEs), occurring ≤1 year from re-treatment completion. A rate of ≥13% for these AEs in a cohort of 55 patients was determined to be unacceptable (86% power, 1-sided α = 0.07). Results: Between 2010 and 2013, 65 patients were accrued, and the first 55 eligible and with 1 year follow-up were analyzed. Median age was 68 years. Twenty-two patients had ductal carcinoma in situ, and 33 had invasive disease: 19 ≤1 cm, 13 >1 to ≤2 cm, and 1 >2 cm. All patients were clinically node negative. Systemic therapy was delivered in 51%. All treatment plans underwent quality review for contouring accuracy and dosimetric compliance. All treatment plans scored acceptable for tumor volume contouring and tumor volume dose-volume analysis. Only 4 (7%) scored unacceptable for organs at risk contouring and organs at risk dose-volume analysis. Treatment-related skin, fibrosis, and/or breast pain AEs were recorded as grade 1 in 64% and grade 2 in 7%, with only 1 (<2%) grade ≥3 and identified as grade 3 fibrosis of deep connective tissue. Conclusion: Partial-breast reirradiation with 3-dimensional conformal radiation therapy after second lumpectomy for patients experiencing in-breast failures after whole-breast irradiation is safe and feasible, with acceptable treatment quality achieved. Skin, fibrosis, and breast pain toxicity was acceptable, and grade 3 toxicity was rare.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Free Energy Perturbation Hamiltonian Replica-Exchange Molecular Dynamics (FEP\H-REMD) for absolute ligand binding free energy calculations.

Free Energy Perturbation with Replica Exchange Molecular Dynamics (FEP/REMD) offers a powerful strategy to improve the convergence of free energy computations. In particular, it has been shown previously that a FEP/REMD scheme allowing random moves within an extended replica ensemble of thermodynamic coupling parameters '{lambda}' can improve the statistical convergence in calculations of absolute binding free energy of ligands to proteins [J. Chem. Theory Comput. 2009, 5, 2583]. In the present study, FEP/REMD is extended and combined with an accelerated MD simulations method based on Hamiltonian replica-exchange MD (H-REMD) to overcome the additional problems arising from the existence of kinetically trapped conformations within the protein receptor. In the combined strategy, each system with a given thermodynamic coupling factor {lambda} in the extended ensemble is further coupled with a set of replicas evolving on a biased energy surface with boosting potentials used to accelerate the interconversion among different rotameric states of the side chains in the neighborhood of the binding site. Exchanges are allowed to occur alternatively along the axes corresponding to the thermodynamic coupling parameter {lambda} and the boosting potential, in an extended dual array of coupled {lambda}- and H-REMD simulations. The method is implemented on the basis of new extensions to the REPDSTR module of the biomolecular simulation program CHARMM. As an illustrative example, the absolute binding free energy of p-xylene to the nonpolar cavity of the L99A mutant of the T4 lysozyme was calculated. The tests demonstrate that the dual {lambda}-REMD and H-REMD simulation scheme greatly accelerates the configurational sampling of the rotameric states of the side chains around the binding pocket, thereby improving the convergence of the FEP computations.

59 BASIC BIOLOGICAL SCIENCES↗

Three-dimensional lithographically-defined organotypic tissue arrays for quantitative analysis of morphogenesis and neoplastic progression

Here we describe a simple micromolding method to construct three-dimensional arrays of organotypic epithelial tissue structures that approximate in vivo histology. An elastomeric stamp containing an array of posts of defined geometry and spacing is used to mold microscale cavities into the surface of type I collagen gels. Epithelial cells are seeded into the cavities and covered with a second layer of collagen. The cells reorganize into hollow tissues corresponding to the geometry of the cavities. Patterned tissue arrays can be produced in 3-4 h and will undergo morphogenesis over the following one to three days. The protocol can easily be adapted to study a variety of tissues and aspects of normal and neoplastic development.

59 BASIC BIOLOGICAL SCIENCES↗

Betatron radiation from density tailored plasmas

In laser wakefield accelerators, electron motion is driven by intense forces that depend on the plasma density. Transverse oscillations in the accelerated electron orbits produce betatron radiation. The electron motion and the resulting betatron radiation spectrum can therefore be controlled by shaping the plasma density along the orbit of the electrons. Here, a method based on the use of a plasma with a longitudinal density variation (density depression or step) is proposed to increase the transverse oscillation amplitude and the energy of the electrons accelerated in a wakefield cavity. For fixed laser parameters, by appropriately tailoring the plasma profile, the betatron radiation emitted by these electrons is significantly increased in both flux and energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Blackbody comparator for thermocouple calibration

MIKES is developing a measurement set-up for calibrating thermocouples in the temperature range 960 °C - 1500 °C. The calibration method is based on direct comparison of thermocouples and radiation thermometers. We have designed a graphite blackbody comparator cell, which is operated in a horizontal single-zone tube furnace. The cell includes two blackbody cavities for radiation temperature measurements. The cavities have openings on opposite sides of the cell, allowing simultaneous measurement with two radiation thermometers. The design of the comparator allows three thermocouples to be calibrated simultaneously. The thermocouples to be calibrated are inserted in thermometer wells around one of the measurement cavities. We characterize the blackbody comparator in terms of repeatability, temperature distribution and emissivity. Finally, we validate the uncertainty analysis by comparing calibration results obtained for type B and S thermocouples to the calibration results reported by Technical Research Institute of Sweden (SP), and MIKES. The agreement in the temperature range 1000 °C - 1500 °C is within 0.90 °C, the average deviation being 0.17 °C.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum chemical approach for condensed-phase thermochemistry: Proposal of a harmonic solvation model

We propose a novel quantum chemical method, called the harmonic solvation model (HSM), for calculating thermochemical parameters in the condensed phase, particularly in the liquid phase. The HSM represents translational and rotational motions of a solute as vibrations interacting with a cavity wall of solvent molecules. As examples, the HSM and the ideal-gas model (IGM) were used for the standard formation reaction of liquid water, combustion reactions of liquid formic acid, methanol, and ethanol, vapor–liquid equilibration of water and ethanol, and dissolution of gaseous CO{sub 2} in water. The numerical results confirmed the reliability and applicability of the HSM. In particular, the temperature dependence of the Gibbs energy of liquid molecules was accurately reproduced by the HSM; for example, the boiling point of water was reasonably determined using the HSM, whereas the conventional IGM treatment failed to obtain a crossing of the two Gibbs energy curves for gaseous and liquid water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Band structure of cavity-type hypersonic phononic crystals fabricated by femtosecond laser-induced two-photon polymerization

The phononic band diagram of a periodic square structure fabricated by femtosecond laser pulse-induced two photon polymerization is recorded by Brillouin light scattering (BLS) at hypersonic (GHz) frequencies and computed by finite element method. The theoretical calculations along the two main symmetry directions quantitatively capture the band diagrams of the air- and liquid-filled structure and moreover represent the BLS intensities. The theory helps identify the observed modes, reveals the origin of the observed bandgaps at the Brillouin zone boundaries, and unravels direction dependent effective medium behavior.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

AGN JET KINETIC POWER AND THE ENERGY BUDGET OF RADIO GALAXY LOBES

Recent results based on the analysis of radio galaxies and their hot X-ray emitting atmospheres suggest that non-radiating particles dominate the energy budget in the lobes of FR I radio galaxies, in some cases by a factor of more than 1000, while radiating particles dominate the energy budget in FR II radio galaxy lobes. This implies a significant difference in the radiative efficiency of the two morphological classes. To test this hypothesis, we have measured the kinetic energy flux for a sample of 3C FR II radio sources using a new method based on the observed parameters of the jet terminal hotspots, and compared the resulting Q{sub jet}-L{sub radio} relation to that obtained for FR I radio galaxies based on X-ray cavity measurements. Contrary to expectations, we find approximate agreement between the Q{sub jet}-L{sub radio} relations determined separately for FR I and FR II radio galaxies. This result is ostensibly difficult to reconcile with the emerging scenario in which the lobes of FR I and FR II radio galaxies have vastly different energy budgets. However, a combination of lower density environment, spectral aging and strong shocks driven by powerful FR II radio galaxies may reduce the radiative efficiency of these objects relative to FR Is and counteract, to some extent, the higher radiative efficiency expected to arise due to the lower fraction of energy in non-radiating particles. An unexpected corollary is that extrapolating the Q{sub jet}-L{sub radio} relation determined for low power FR I radio galaxies provides a reasonable approximation for high power sources, despite their apparently different lobe compositions.

79 ASTRONOMY AND ASTROPHYSICS↗

Pass-through Mach-Zehnder topologies for macroscopic quantum measurements

Several relatively small-scale experimental setups, aimed on prototyping of future laser gravitational-wave detectors and testing of new methods of quantum measurements with macroscopic mechanical objects, are under development now. In these devices, not devoted directly to the gravitational-wave detection, Mach-Zehnder interferometer with pass-through Fabry-Perot cavities in the arms can be used instead of the standard Michelson/Fabry-Perot one. The advantage of this topology is that it does not contain high-reflectivity end mirrors with multilayer coatings, which Brownian noise could constitute the major part of the noise budget of the Michelson/Fabry-Perot interferometers. We consider here two variants of this topology: the 'ordinary' position meter scheme, and a new variant of the quantum speed meter.

79 ASTRONOMY AND ASTROPHYSICS↗

Continuous magnetic flux pump

A method and means for altering the intensity of a magnetic field by transposing flux from one location to the location desired fro the magnetic field are examined. The device described includes a pair of communicating cavities formed in a block of superconducting material, is dimensioned to be insertable into one of the cavities and to substantially fill the cavity. Magnetic flux is first trapped in the cavities by establishing a magnetic field while the superconducting material is above the critical temperature at which it goes superconducting. Thereafter, the temperature of the material is reduced below the critical value, and then the exciting magnetic field may be removed. By varying the ratios of the areas of the two cavities, it is possible to produce a field having much greater flux density in the second, smaller cavity, into which the flux transposed.

Hildebrandt, A. F.↗

Time-dependent thermocapillary convection in a Cartesian cavity - Numerical results for a moderate Prandtl number fluid

The present numerical simulation explores a thermal-convective mechanism for oscillatory thermocapillary convection in a shallow Cartesian cavity for a Prandtl number 6.78 fluid. The computer program developed for this simulation integrates the two-dimensional, time-dependent Navier-Stokes equations and the energy equation by a time-accurate method on a stretched, staggered mesh. Flat free surfaces are assumed. The instability is shown to depend upon temporal coupling between large scale thermal structures within the flow field and the temperature sensitive free surface. A primary result of this study is the development of a stability diagram presenting the critical Marangoni number separating steady from the time-dependent flow states as a function of aspect ratio for the range of values between 2.3 and 3.8. Within this range, a minimum critical aspect ratio near 2.3 and a minimum critical Marangoni number near 20,000 are predicted below which steady convection is found.

Peltier, L. J.↗

Stabilizing an optoelectronic microwave oscillator with photonic filters

This paper compares methods of active stabilization of an optoelectronic microwave oscillator (OEO) based on insertion of a source of optical group delay into an OEO loop. The performance of an OEO stabilized with either a high- optical cavity or an atomic cell is analyzed. We show that the elements play a role of narrow-band microwave filters improving an OEO stability.

Atomic clocks electromagnetically induced transpar↗