Search NASA⌕ Search

SEARCH · Search NASA

Results for “diffusion couples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Theoretical study of the nitrogen atom hyperfine coupling constant

The nitrogen-atom isotropic hyperfine coupling constant A(iso) is studied as a function of improvements in both the one-particle and n-particle basis sets. The study underscores the importance of diffuse basis functions. For example, the (9s 5p) primitive set of Huzinaga (1965) augmented with an even-tempered diffuse s function yields values for A(iso) that are virtually identical to an energy-optimized (23s 12p) even-tempered set. The A(iso) constant is found to converge relatively quickly with increasing l quantum numbers: d, f, and g functions are estimated to contribute 2.5 + or - 0.2, 0.4 + or - 0.1, and 0.05 + or - 0.05 MHz, respectively. Full CI calibration calculations indicate that very high levels of correlation treatment are required for quantitative results. In addition, a strong coupling is observed between the one-particle and n-particle requirements. The best result, 10.4 MHz, is in excellent agreement with the accurate experimental value of 10.4509 MHz.

Bauschlicher, Charles W., Jr.↗

Particle Size Distribution Dynamics Can Help Constrain the Phase State of Secondary Organic Aerosol

Particle phase state is a property of atmospheric aerosols that has important implications for the formation, evolution, and gas/particle partitioning of secondary organic aerosol (SOA). In this work, we use a size-resolved chemistry and microphysics model (SOM-TOMAS), updated to include an explicit treatment of particle phase state, to constrain the bulk diffusion coefficient (Db) of SOA produced from ??- pinene ozonolysis. By leveraging data from laboratory experiments performed in the absence of a seed and under dry conditions, we find that the Db for SOA can be constrained (1-7 ×10-15 cm2 s-1 in these experiments) by simultaneously reproducing the time-varying SOA mass concentrations and the evolution of the particle size distribution. Another version of our model that used the predicted SOA composition to calculate the glass transition temperature, viscosity, and, ultimately, Db (~10-15 cm2 s-1) of the SOA was able to reproduce the mass and size distribution measurements when we included oligomer formation (oligomers accounted for about a fifth of the SOA mass). Our work highlights the potential of a size resolved SOA model to constrain the particle phase state of SOA by utilizing historical measurements of the evolution of the particle size distribution.

He, Yicong↗

Transition and separation process in brine channels formation

In this paper, we discuss the formation of brine channels in sea ice. The model includes a time-dependent Ginzburg-Landau equation for the solid-liquid phase change, a diffusion equation of the Cahn-Hilliard kind for the solute dynamics, and the heat equation for the temperature change. The macroscopic motion of the fluid is also considered, so the resulting differential system couples with the Navier-Stokes equation. The compatibility of this system with the thermodynamic laws and a maximum theorem is proved.

42 ENGINEERING↗

Multi-scale time-resolved electron diffraction: A case study in moiré materials

Ultrafast-optical-pump — structural-probe measurements, including ultrafast electron and x-ray scattering, provide direct experimental access to the fundamental timescales of atomic motion, and are thus foundational techniques for studying matter out of equilibrium. High-performance detectors are needed in scattering experiments to obtain maximum scientific value from every probe particle. Here we deploy a hybrid pixel array direct electron detector to perform ultrafast electron diffraction experiments on a WSe 2 /MoSe 2 2D heterobilayer, resolving the weak features of diffuse scattering and moiré superlattice structure without saturating the zero order peak. Enabled by the detector’s high frame rate, we show that a chopping technique provides diffraction difference images with signal-to-noise at the shot noise limit. Finally, we demonstrate that a fast detector frame rate coupled with a high repetition rate probe can provide continuous time resolution from femtoseconds to seconds, enabling us to perform a scanning ultrafast electron diffraction experiment that maps thermal transport in WSe 2 /MoSe 2 and resolves distinct diffusion mechanisms in space and time.

36 MATERIALS SCIENCE↗

Validation of nonlinear gyrokinetic simulations of L- and I-mode plasmas on Alcator C-Mod

New validation of global, nonlinear, ion-scale gyrokinetic simulations (GYRO) is carried out for L- and I-mode plasmas on Alcator C-Mod, utilizing heat fluxes, profile stiffness, and temperature fluctuations. Previous work at C-Mod found that ITG/TEM-scale GYRO simulations can match both electron and ion heat fluxes within error bars in I-mode [White PoP 2015], suggesting that multi-scale (cross-scale coupling) effects [Howard PoP 2016] may be less important in I-mode than in L-mode. New results presented here, however, show that global, nonlinear, ion-scale GYRO simulations are able to match the experimental ion heat flux, but underpredict electron heat flux (at most radii), electron temperature fluctuations, and perturbative thermal diffusivity in both L- and I-mode. Linear addition of electron heat flux from electron scale runs does not resolve this discrepancy. These results indicate that single-scale simulations do not sufficiently describe the I-mode core transport, and that multi-scale (coupled electron- and ion-scale) transport models are needed. A preliminary investigation with multi-scale TGLF, however, was unable to resolve the discrepancy between ion-scale GYRO and experimental electron heat fluxes and perturbative diffusivity, motivating further work with multi-scale GYRO simulations and a more comprehensive study with multi-scale TGLF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Weak chaos in the disordered nonlinear Schroedinger chain: Destruction of Anderson localization by Arnold diffusion

Research Highlights: > In a one-dimensional disordered chain of oscillators all normal modes are localized. > Nonlinearity leads to chaotic dynamics. > Chaos is concentrated on rare chaotic spots. > Chaotic spots drive energy exchange between oscillators. > Macroscopic transport coefficients are obtained. - Abstract: The subject of this study is the long-time equilibration dynamics of a strongly disordered one-dimensional chain of coupled weakly anharmonic classical oscillators. It is shown that chaos in this system has a very particular spatial structure: it can be viewed as a dilute gas of chaotic spots. Each chaotic spot corresponds to a stochastic pump which drives the Arnold diffusion of the oscillators surrounding it, thus leading to their relaxation and thermalization. The most important mechanism of equilibration at long distances is provided by random migration of the chaotic spots along the chain, which bears analogy with variable-range hopping of electrons in strongly disordered solids. The corresponding macroscopic transport equations are obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coarse-graining and hybrid methods for efficient simulation of stochastic multi-scale models of tumour growth

The development of hybrid methodologies is of current interest in both multi-scale modelling and stochastic reaction–diffusion systems regarding their applications to biology. We formulate a hybrid method for stochastic multi-scale models of cells populations that extends the remit of existing hybrid methods for reaction–diffusion systems. Such method is developed for a stochastic multi-scale model of tumour growth, i.e. population-dynamical models which account for the effects of intrinsic noise affecting both the number of cells and the intracellular dynamics. In order to formulate this method, we develop a coarse-grained approximation for both the full stochastic model and its mean-field limit. Such approximation involves averaging out the age-structure (which accounts for the multi-scale nature of the model) by assuming that the age distribution of the population settles onto equilibrium very fast. We then couple the coarse-grained mean-field model to the full stochastic multi-scale model. By doing so, within the mean-field region, we are neglecting noise in both cell numbers (population) and their birth rates (structure). This implies that, in addition to the issues that arise in stochastic-reaction diffusion systems, we need to account for the age-structure of the population when attempting to couple both descriptions. We exploit our coarse-graining model so that, within the mean-field region, the age-distribution is in equilibrium and we know its explicit form. This allows us to couple both domains consistently, as upon transference of cells from the mean-field to the stochastic region, we sample the equilibrium age distribution. Furthermore, our method allows us to investigate the effects of intracellular noise, i.e. fluctuations of the birth rate, on collective properties such as travelling wave velocity. We show that the combination of population and birth-rate noise gives rise to large fluctuations of the birth rate in the region at the leading edge of front, which cannot be accounted for by the coarse-grained model. Such fluctuations have non-trivial effects on the wave velocity. Beyond the development of a new hybrid method, we thus conclude that birth-rate fluctuations are central to a quantitatively accurate description of invasive phenomena such as tumour growth. - Highlights: • A hybrid method for stochastic multi-scale models of cells populations that extends existing hybrid methods for reaction–diffusion system. • Our analysis unveils non-trivial macroscopic effects triggered by noise at the level of structuring variables. • Our hybrid method hugely speeds up age-structured SSA simulations while preserving stochastic effects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Elastic Flow Modeling for Hydropower Digital Twins

This report details the elastic, unsteady, one-dimensional flow equations that are used to model flow through a penstock in a hydropower facility. The elastic flow model is accurate even in cases of fast transients, long penstock length, and high gravitation head. The compressibility of the water and elasticity of the pipe walls are explicitly accounted for in the developed models so that the water hammer phenomena can be accurately captured. The elastic flow model is coupled to a mechanistic turbine model to resolve the dynamic feedbacks between the elastic water column and the turbine rotation rate. A finite volume method is employed to solve the governing equations, and the method is shown to have low numerical diffusion in sharp gradient phenomena, such as those encountered when simulating water hammer. The method is applied to single dimensional linear advection benchmark problem and numerical results are compared with analytic results. This is followed on by an application to a full hydropower system with a coupled turbine. The elastic flow model results are compared against an inelastic model.

13 HYDRO ENERGY↗

Application of subgroup decomposition in diffusion theory to gas cooled thermal reactor problem

In this paper, the accuracy and computational efficiency of the subgroup decomposition (SGD) method in diffusion theory is assessed in a ID benchmark problem characteristic of gas cooled thermal systems. This method can be viewed as a significant improvement in accuracy of standard coarse-group calculations used for VHTR whole core analysis in which core environmental effect and energy angle coupling are pronounced. It is shown that a 2-group SGD calculation reproduces fine-group (47) results with 1.5 to 6 times faster computational speed depending on the stabilizing schemes while it is as efficient as single standard 6-group diffusion calculation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

sashevis (b1)

The shortwave array spectroradiometer—hemispheric (SASHE) uses a hemispheric spectralon diffuser and rotating shadowband similar to the MFRSR and RSS instruments, so it also provides spectrally resolved, direct-normal, diffuse-horizontal, and total-horizontal irradiances, and can be calibrated in situ via Langley regression. The SASHE incorporates two Avantes fiber-coupled spectroradiometers (Avaspec ULS 2048 CCD and Avaspec NIR256-1.7) for visible and near-infrared detection in the wavelength range 350-1700 nm. The spectral resolution is 2.4 nm for the ULS 2048 CCD and 6 nm for the NIR256-1.7. Like the SWS and SASZE, an external collector mounted outdoors is connected via fiber-optic cable to a pair of spectroradiometers housed indoors, so the entire spectral range is measured simultaneously for both spectroradiometers. For the typical shadowband measurement, the spectroradiometers are operated with one measurement per second, but the entire shadowband sequence takes about 20 seconds, so this is the measurement interval for the irradiances. The SASHE operating sequence is configurable and supports alternate programmed sequences as a function of solar zenith angle. For example, it currently employs different sequences for high sun angles, low sun angles, and twilight conditions when the sun is below the horizon but the sky is not yet fully dark. It also includes a mode where visible spectra are collected rapidly while the band is moved over a range of near-sun angles to characterize the forward-scattered radiation. The SASHE data are preliminarily calibrated through comparison with calibrated lamps. The accuracy of irradiance produced by the SASHE is expected to be better than ±5%, which includes calibration and instrument stability errors. Under suitably uniform atmospheric conditions, higher calibration accuracy and precisions (±1%) can be obtained when the responsivity is tied to the solar extraterrestrial irradiance via Langley regression plots. This approach is recommended when high-precision measurements of optical depth are required.

54 ENVIRONMENTAL SCIENCES↗

sashemfr (b1)

The shortwave array spectroradiometer—hemispheric (SASHE) uses a hemispheric spectralon diffuser and rotating shadowband similar to the MFRSR and RSS instruments, so it also provides spectrally resolved, direct-normal, diffuse-horizontal, and total-horizontal irradiances, and can be calibrated in situ via Langley regression. The SASHE incorporates two Avantes fiber-coupled spectroradiometers (Avaspec ULS 2048 CCD and Avaspec NIR256-1.7) for visible and near-infrared detection in the wavelength range 350-1700 nm. The spectral resolution is 2.4 nm for the ULS 2048 CCD and 6 nm for the NIR256-1.7. Like the SWS and SASZE, an external collector mounted outdoors is connected via fiber-optic cable to a pair of spectroradiometers housed indoors, so the entire spectral range is measured simultaneously for both spectroradiometers. For the typical shadowband measurement, the spectroradiometers are operated with one measurement per second, but the entire shadowband sequence takes about 20 seconds, so this is the measurement interval for the irradiances. The SASHE operating sequence is configurable and supports alternate programmed sequences as a function of solar zenith angle. For example, it currently employs different sequences for high sun angles, low sun angles, and twilight conditions when the sun is below the horizon but the sky is not yet fully dark. It also includes a mode where visible spectra are collected rapidly while the band is moved over a range of near-sun angles to characterize the forward-scattered radiation. The SASHE data are preliminarily calibrated through comparison with calibrated lamps. The accuracy of irradiance produced by the SASHE is expected to be better than ±5%, which includes calibration and instrument stability errors. Under suitably uniform atmospheric conditions, higher calibration accuracy and precisions (±1%) can be obtained when the responsivity is tied to the solar extraterrestrial irradiance via Langley regression plots. This approach is recommended when high-precision measurements of optical depth are required.

54 ENVIRONMENTAL SCIENCES↗

sashenir (b1)

The shortwave array spectroradiometer—hemispheric (SASHE) uses a hemispheric spectralon diffuser and rotating shadowband similar to the MFRSR and RSS instruments, so it also provides spectrally resolved, direct-normal, diffuse-horizontal, and total-horizontal irradiances, and can be calibrated in situ via Langley regression. The SASHE incorporates two Avantes fiber-coupled spectroradiometers (Avaspec ULS 2048 CCD and Avaspec NIR256-1.7) for visible and near-infrared detection in the wavelength range 350-1700 nm. The spectral resolution is 2.4 nm for the ULS 2048 CCD and 6 nm for the NIR256-1.7. Like the SWS and SASZE, an external collector mounted outdoors is connected via fiber-optic cable to a pair of spectroradiometers housed indoors, so the entire spectral range is measured simultaneously for both spectroradiometers. For the typical shadowband measurement, the spectroradiometers are operated with one measurement per second, but the entire shadowband sequence takes about 20 seconds, so this is the measurement interval for the irradiances. The SASHE operating sequence is configurable and supports alternate programmed sequences as a function of solar zenith angle. For example, it currently employs different sequences for high sun angles, low sun angles, and twilight conditions when the sun is below the horizon but the sky is not yet fully dark. It also includes a mode where visible spectra are collected rapidly while the band is moved over a range of near-sun angles to characterize the forward-scattered radiation. The SASHE data are preliminarily calibrated through comparison with calibrated lamps. The accuracy of irradiance produced by the SASHE is expected to be better than ±5%, which includes calibration and instrument stability errors. Under suitably uniform atmospheric conditions, higher calibration accuracy and precisions (±1%) can be obtained when the responsivity is tied to the solar extraterrestrial irradiance via Langley regression plots. This approach is recommended when high-precision measurements of optical depth are required.

54 ENVIRONMENTAL SCIENCES↗

sashenirlowsun (a0)

The shortwave array spectroradiometer—hemispheric (SASHE) uses a hemispheric spectralon diffuser and rotating shadowband similar to the MFRSR and RSS instruments, so it also provides spectrally resolved, direct-normal, diffuse-horizontal, and total-horizontal irradiances, and can be calibrated in situ via Langley regression. The SASHE incorporates two Avantes fiber-coupled spectroradiometers (Avaspec ULS 2048 CCD and Avaspec NIR256-1.7) for visible and near-infrared detection in the wavelength range 350-1700 nm. The spectral resolution is 2.4 nm for the ULS 2048 CCD and 6 nm for the NIR256-1.7. Like the SWS and SASZE, an external collector mounted outdoors is connected via fiber-optic cable to a pair of spectroradiometers housed indoors, so the entire spectral range is measured simultaneously for both spectroradiometers. For the typical shadowband measurement, the spectroradiometers are operated with one measurement per second, but the entire shadowband sequence takes about 20 seconds, so this is the measurement interval for the irradiances. The SASHE operating sequence is configurable and supports alternate programmed sequences as a function of solar zenith angle. For example, it currently employs different sequences for high sun angles, low sun angles, and twilight conditions when the sun is below the horizon but the sky is not yet fully dark. It also includes a mode where visible spectra are collected rapidly while the band is moved over a range of near-sun angles to characterize the forward-scattered radiation. The SASHE data are preliminarily calibrated through comparison with calibrated lamps. The accuracy of irradiance produced by the SASHE is expected to be better than ±5%, which includes calibration and instrument stability errors. Under suitably uniform atmospheric conditions, higher calibration accuracy and precisions (±1%) can be obtained when the responsivity is tied to the solar extraterrestrial irradiance via Langley regression plots. This approach is recommended when high-precision measurements of optical depth are required.

54 ENVIRONMENTAL SCIENCES↗

sashevislowsun (a0)

The shortwave array spectroradiometer—hemispheric (SASHE) uses a hemispheric spectralon diffuser and rotating shadowband similar to the MFRSR and RSS instruments, so it also provides spectrally resolved, direct-normal, diffuse-horizontal, and total-horizontal irradiances, and can be calibrated in situ via Langley regression. The SASHE incorporates two Avantes fiber-coupled spectroradiometers (Avaspec ULS 2048 CCD and Avaspec NIR256-1.7) for visible and near-infrared detection in the wavelength range 350-1700 nm. The spectral resolution is 2.4 nm for the ULS 2048 CCD and 6 nm for the NIR256-1.7. Like the SWS and SASZE, an external collector mounted outdoors is connected via fiber-optic cable to a pair of spectroradiometers housed indoors, so the entire spectral range is measured simultaneously for both spectroradiometers. For the typical shadowband measurement, the spectroradiometers are operated with one measurement per second, but the entire shadowband sequence takes about 20 seconds, so this is the measurement interval for the irradiances. The SASHE operating sequence is configurable and supports alternate programmed sequences as a function of solar zenith angle. For example, it currently employs different sequences for high sun angles, low sun angles, and twilight conditions when the sun is below the horizon but the sky is not yet fully dark. It also includes a mode where visible spectra are collected rapidly while the band is moved over a range of near-sun angles to characterize the forward-scattered radiation. The SASHE data are preliminarily calibrated through comparison with calibrated lamps. The accuracy of irradiance produced by the SASHE is expected to be better than ±5%, which includes calibration and instrument stability errors. Under suitably uniform atmospheric conditions, higher calibration accuracy and precisions (±1%) can be obtained when the responsivity is tied to the solar extraterrestrial irradiance via Langley regression plots. This approach is recommended when high-precision measurements of optical depth are required.

54 ENVIRONMENTAL SCIENCES↗

sashevishisun (a0)

The shortwave array spectroradiometer—hemispheric (SASHE) uses a hemispheric spectralon diffuser and rotating shadowband similar to the MFRSR and RSS instruments, so it also provides spectrally resolved, direct-normal, diffuse-horizontal, and total-horizontal irradiances, and can be calibrated in situ via Langley regression. The SASHE incorporates two Avantes fiber-coupled spectroradiometers (Avaspec ULS 2048 CCD and Avaspec NIR256-1.7) for visible and near-infrared detection in the wavelength range 350-1700 nm. The spectral resolution is 2.4 nm for the ULS 2048 CCD and 6 nm for the NIR256-1.7. Like the SWS and SASZE, an external collector mounted outdoors is connected via fiber-optic cable to a pair of spectroradiometers housed indoors, so the entire spectral range is measured simultaneously for both spectroradiometers. For the typical shadowband measurement, the spectroradiometers are operated with one measurement per second, but the entire shadowband sequence takes about 20 seconds, so this is the measurement interval for the irradiances. The SASHE operating sequence is configurable and supports alternate programmed sequences as a function of solar zenith angle. For example, it currently employs different sequences for high sun angles, low sun angles, and twilight conditions when the sun is below the horizon but the sky is not yet fully dark. It also includes a mode where visible spectra are collected rapidly while the band is moved over a range of near-sun angles to characterize the forward-scattered radiation. The SASHE data are preliminarily calibrated through comparison with calibrated lamps. The accuracy of irradiance produced by the SASHE is expected to be better than ±5%, which includes calibration and instrument stability errors. Under suitably uniform atmospheric conditions, higher calibration accuracy and precisions (±1%) can be obtained when the responsivity is tied to the solar extraterrestrial irradiance via Langley regression plots. This approach is recommended when high-precision measurements of optical depth are required.

54 ENVIRONMENTAL SCIENCES↗

sashenirhisun (a0)

The shortwave array spectroradiometer—hemispheric (SASHE) uses a hemispheric spectralon diffuser and rotating shadowband similar to the MFRSR and RSS instruments, so it also provides spectrally resolved, direct-normal, diffuse-horizontal, and total-horizontal irradiances, and can be calibrated in situ via Langley regression. The SASHE incorporates two Avantes fiber-coupled spectroradiometers (Avaspec ULS 2048 CCD and Avaspec NIR256-1.7) for visible and near-infrared detection in the wavelength range 350-1700 nm. The spectral resolution is 2.4 nm for the ULS 2048 CCD and 6 nm for the NIR256-1.7. Like the SWS and SASZE, an external collector mounted outdoors is connected via fiber-optic cable to a pair of spectroradiometers housed indoors, so the entire spectral range is measured simultaneously for both spectroradiometers. For the typical shadowband measurement, the spectroradiometers are operated with one measurement per second, but the entire shadowband sequence takes about 20 seconds, so this is the measurement interval for the irradiances. The SASHE operating sequence is configurable and supports alternate programmed sequences as a function of solar zenith angle. For example, it currently employs different sequences for high sun angles, low sun angles, and twilight conditions when the sun is below the horizon but the sky is not yet fully dark. It also includes a mode where visible spectra are collected rapidly while the band is moved over a range of near-sun angles to characterize the forward-scattered radiation. The SASHE data are preliminarily calibrated through comparison with calibrated lamps. The accuracy of irradiance produced by the SASHE is expected to be better than ±5%, which includes calibration and instrument stability errors. Under suitably uniform atmospheric conditions, higher calibration accuracy and precisions (±1%) can be obtained when the responsivity is tied to the solar extraterrestrial irradiance via Langley regression plots. This approach is recommended when high-precision measurements of optical depth are required.

54 ENVIRONMENTAL SCIENCES↗

Correspondence principle for the diffusive dynamics of a quartic oscillator: Deterministic aspects and the role of temperature

The correspondence principle is investigated in the framework of deterministic predictions for individual systems. Exact analytical results are obtained for the quantum and Liouvillian dynamics of a nonlinear oscillator coupled to a phase-damping reservoir at a finite temperature. In this context, the time of critical wave function spreading - the Ehrenfest time - emerges as the characteristic time scale within which the concept of deterministic behavior is admissible in physics. A scenario of quasideterminism may then be defined, within which the motion is experimentally indistinguishable from the truly deterministic motion of Newtonian mechanics. Beyond this time scale, predictions for individual systems can be given only statistically and, in this case, it is shown that diffusive decoherence is indeed a necessary ingredient to establish the quantum-classical correspondence. Moreover, the high-temperature regime is shown to be an additional condition for the quantum-classical transition and, accordingly, a lower bound for the reservoir temperature is derived for our model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Overset meshing coupled with hybridizable discontinuous Galerkin finite elements

We introduce the use of hybridizable discontinuous Galerkin (HDG) finite element methods on overlapping (overset) meshes. Overset mesh methods are advantageous for solving problems on complex geometrical domains. We also combine geometric flexibility of overset methods with the advantages of HDG methods: arbitrarily high-order accuracy, reduced size of the global discrete problem, and the ability to solve elliptic, parabolic, and/or hyperbolic problems with a unified form of discretization. This approach to developing the ‘overset HDG’ method is to couple the global solution from one mesh to the local solution on the overset mesh. We present numerical examples for steady convection–diffusion and static elasticity problems. The examples demonstrate optimal order convergence in all primal fields for an arbitrary amount of overlap of the underlying meshes.

42 ENGINEERING↗