Search NASA⌕ Search

SEARCH · Search NASA

Results for “error reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Wattchmen: Watching the Wattchers – High Fidelity, Flexible GPU Energy Modeling

Modern GPU-rich HPC systems are increasingly becoming energy-constrained. Thus, understanding an application’s energy consumption becomes essential. Unfortunately, current GPU energy attribution techniques are either inaccurate, inflexible, or outdated. Therefore, we propose Wattchmen, a flexible methodology for measuring, attributing, and predicting GPU energy consumption. We construct a per-instruction energy model using a diverse set of microbenchmarks to systematically quantify the energy consumption of GPU instructions, enabling finer-grain prediction and energy consumption breakdowns for applications. Compared with the state-of-the-art systems like AccelWattch (32%) and Guser (25%), across 16 popular GPGPU, graph analytics, HPC, and ML workloads, Wattchmen reduces the mean absolute percent error (MAPE) to 14% on V100 GPUs. Furthermore, we show that Wattchmen provides similar MAPEs for water-cooled V100s (15%) and extends to later architectures, including air-cooled A100 (11%) and H100 (12%) GPUs. Finally, to further demonstrate Wattchmen ’s value, we apply it to applications such as Backprop and QMCPACK, where Wattchmen ’s insights enable energy reductions of up to 35%.

Tran, Brandon [University of Wisconsin, Madison] (↗

Principal Component Noise Filtering for NAST-I Radiometric Calibration

The National Polar-orbiting Operational Environmental Satellite System (NPOESS) Airborne Sounder Testbed- Interferometer (NAST-I) instrument is a high-resolution scanning interferometer that measures emitted thermal radiation between 3.3 and 18 microns. The NAST-I radiometric calibration is achieved using internal blackbody calibration references at ambient and hot temperatures. In this paper, we introduce a refined calibration technique that utilizes a principal component (PC) noise filter to compensate for instrument distortions and artifacts, therefore, further improve the absolute radiometric calibration accuracy. To test the procedure and estimate the PC filter noise performance, we form dependent and independent test samples using odd and even sets of blackbody spectra. To determine the optimal number of eigenvectors, the PC filter algorithm is applied to both dependent and independent blackbody spectra with a varying number of eigenvectors. The optimal number of PCs is selected so that the total root-mean-square (RMS) error is minimized. To estimate the filter noise performance, we examine four different scenarios: apply PC filtering to both dependent and independent datasets, apply PC filtering to dependent calibration data only, apply PC filtering to independent data only, and no PC filters. The independent blackbody radiances are predicted for each case and comparisons are made. The results show significant reduction in noise in the final calibrated radiances with the implementation of the PC filtering algorithm.

Tian, Jialin↗

JWST Pathfinder Telescope Integration

The James Webb Space Telescope (JWST) is a 6.5m, segmented, IR telescope that will explore the first light of the universe after the big bang. In 2014, a major risk reduction effort related to the Alignment, Integration, and Test (AI&T) of the segmented telescope was completed. The Pathfinder telescope includes two Primary Mirror Segment Assemblies (PMSA's) and the Secondary Mirror Assembly (SMA) onto a flight-like composite telescope backplane. This pathfinder allowed the JWST team to assess the alignment process and to better understand the various error sources that need to be accommodated in the flight build. The successful completion of the Pathfinder Telescope provides a final integration roadmap for the flight operations that will start in August 2015.

JWST↗

Height Error Correction for the New SRTM Elevation Product

The Shuttle Radar Topography Mission (SRTM), carrying a single-pass interferometric synthetic aperture radar(SAR) instrument, collected a global elevation data set, which has been widely used in scientific, military and commercial communities. In the new proposed NASA SRTM reprocessing task, the SRTM elevation data is going to be processed at higher spatial resolution and with improved height accuracy. Upon completion, the improved SRTM product will be freely available. This paper describes the calibration approaches for reduction of elevation ripple effects and height accuracy improvements.

Synthetic Aperture Radar Interferometry (InSAR)↗

Cone Beam Computed Tomography-Derived Adaptive Radiotherapy for Radical Treatment of Esophageal Cancer

Purpose: To investigate the potential for reduction in normal tissue irradiation by creating a patient specific planning target volume (PTV) using cone beam computed tomography (CBCT) imaging acquired in the first week of radiotherapy for patients receiving radical radiotherapy. Methods and materials: Patients receiving radical RT for carcinoma of the esophagus were investigated. The PTV is defined as CTV(tumor, nodes) plus esophagus outlined 3 to 5 cm cranio-caudally and a 1.5-cm circumferential margin is added (clinical plan). Prefraction CBCT are acquired on Days 1 to 4, then weekly. No correction for setup error made. The images are imported into the planning system. The tumor and esophagus for the length of the PTV are contoured on each CBCT and 5 mm margin is added. A composite volume (PTV1) is created using Week 1 composite CBCT volumes. The same process is repeated using CBCT Week 2 to 6 (PTV2). A new plan is created using PTV1 (adaptive plan). The coverage of the 95% isodose of PTV1 is evaluated on PTV2. Dose-volume histograms (DVH) for lungs, heart, and cord for two plans are compared. Results: A total of 139 CBCT for 14 cases were analyzed. For the adaptive plan the coverage of the 95% prescription isodose for PTV1 = 95.6% +- 4% and the PTV2 = 96.8% +- 4.1% (t test, 0.19). Lungs V20 (15.6 Gy vs. 10.2 Gy) and heart mean dose (26.9 Gy vs. 20.7 Gy) were significantly smaller for the adaptive plan. Conclusions: A reduced planning volume can be constructed within the first week of treatment using CBCT. A single plan modification can be performed within the second week of treatment with considerable reduction in organ at risk dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sparsity of the electron repulsion integral tensor using different localized virtual orbital representations in local second-order Møller–Plesset theory

Utilizing localized orbitals, local correlation theory can reduce the unphysically high system-size scaling of post-Hartree–Fock (post-HF) methods to linear scaling in insulating molecules. The sparsity of the four-index electron repulsion integral (ERI) tensor is central to achieving this reduction. For second-order Møller–Plesset theory (MP2), one of the simplest post-HF methods, only the (ia|jb) ERIs are needed, coupling occupied orbitals i, j and virtuals a, b. In this paper, we compare the numerical sparsity (called the “ragged list”) and two other approaches revealing the low-rank sparsity of the ERI. The ragged list requires only one set of (localized) virtual orbitals, and we find that the orthogonal valence virtual-hard virtual set of virtuals originally proposed by Subotnik et al. gives the sparsest ERI tensor. To further compress the ERI tensor, the pair natural orbital (PNO) type representation uses different sets of virtual orbitals for different occupied orbital pairs, while the occupied-specific virtual (OSV) approach uses different virtuals for each occupied orbital. Here, our results indicate that while the low-rank PNO representation achieves significant rank reduction, it also requires more memory than the ragged list. The OSV approach requires similar memory to that of the ragged list, but it involves greater algorithmic complexity. An approximation (called the “fixed sparsity pattern”) for solving the local MP2 equations using the numerically sparse ERI tensor is proposed and tested to be sufficiently accurate and to have highly controllable error. A low-scaling local MP2 algorithm based on the ragged list and the fixed sparsity pattern is therefore promising.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

QCD sum rule determination of the charm-quark mass

QCD sum rules involving mixed inverse moment integration kernels are used in order to determine the running charm-quark mass in the MS scheme. Both the high and the low energy expansion of the vector current correlator are involved in this determination. The optimal integration kernel turns out to be of the form p(s)=1-(s{sub 0}/s){sup 2}, where s{sub 0} is the onset of perturbative QCD. This kernel enhances the contribution of the well known narrow resonances, and reduces the impact of the data in the range s{approx_equal}20-25 GeV{sup 2}. This feature leads to a substantial reduction in the sensitivity of the results to changes in s{sub 0}, as well as to a much reduced impact of the experimental uncertainties in the higher resonance region. The value obtained for the charm-quark mass in the MS scheme at a scale of 3 GeV is m{sub c}(3 GeV)=987{+-}9 MeV, where the error includes all sources of uncertainties added in quadrature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulation gravity modeling to spacecraft-tracking data - Analysis and application

It is proposed that line-of-sight gravity measurements derived from spacecraft-tracking data can be used for quantitative subsurface density modeling by suitable orbit simulation procedures. Such an approach avoids complex dynamic reductions and is analogous to the modeling of conventional surface gravity data. This procedure utilizes the vector calculations of a given gravity model in a simplified trajectory integration program that simulates the line-of-sight gravity. Solutions from an orbit simulation inversion and a dynamic inversion on Doppler observables compare well (within 1% in mass and size), and the error sources in the simulation approximation are shown to be quite small. An application of this technique is made to lunar crater gravity anomalies by simulating the complete Bouguer correction to several large young lunar craters. It is shown that the craters all have negative Bouguer anomalies.

Phillips, R. J.↗

Voyager high gain antenna calibration and pointing

A mathematical description of the data reduction technique used in analyzing Voyager calibration data is presented. To achieve the required telecommunication link performance, highly accurate pointing of the Voyager high gain antenna boresight relative to earth is necessary. To provide the optimum pointing, in-flight calibrations of the high gain antenna pointing mechanism are regularly made, and the design of the calibration and the antenna error models is delineated. It is shown that due to the use of wide angle sun sensors for celestial attitude control, the Voyager antenna error model differs from those of previous missions. Results of the in-flight calibrations and their implementation in improving the antenna pointing are also presented.

Jahanshahi, M. H.↗

Characterization of the Q-switched MOBLAS Laser Transmitter and Its Ranging Performance Relative to a PTM Q-switched System

A prototype Q-switched Nd:YAG laser transmitter intended for use in the NASA mobile laser ranging system was subjected to various tests of temporal pulse shape and stability, output energy and stability, beam divergence, and range bias errors. Peak to peak variations in the mean range were as large as 30 cm and drift rates of system bias with time as large as 6 mm per minute of operation were observed. The incorporation of a fast electro-optic cavity dump into the oscillator gave significantly improved results. Reevaluation of the ranging performance after modification showed a reduction in the peak to peak variation in the mean range to the 2 or 3 cm level and a drift rate of system time biases of less than 1 mm per minute of operation. A qualitative physical explanation for the superior performance of cavity dumped lasers is given.

Degnan, J. J., III↗

An accuracy assessment of Magellan Very Long Baseline Interferometry (VLBI)

Very Long Baseline Interferometry (VLBI) measurements of the Magellan spacecraft's angular position and velocity were made during July through September, 1989, during the spacecraft's heliocentric flight to Venus. The purpose of this data acquisition and reduction was to verify this data type for operational use before Magellan is inserted into Venus orbit, in August, 1990. The accuracy of these measurements are shown to be within 20 nanoradians in angular position, and within 5 picoradians/sec in angular velocity. The media effects and their calibrations are quantified; the wet fluctuating troposphere is the dominant source of measurement error for angular velocity. The charged particle effect is completely calibrated with S- and X-Band dual-frequency calibrations. Increasing the accuracy of the Earth platform model parameters, by using VLBI-derived tracking station locations consistent with the planetary ephemeris frame, and by including high frequency Earth tidal terms in the Earth rotation model, add a few nanoradians improvement to the angular position measurements. Angular velocity measurements were insensitive to these Earth platform modelling improvements.

Engelhardt, D. B.↗

A reconsideration of the noise equivalent power and the data analysis procedure for the infrared imaging video bolometers

The infrared imaging video bolometer (IRVB) used for measurement of the two-dimensional (2D) radiation profiles from the Large Helical Device has been significantly upgraded recently to improve its signal to noise ratio, sensitivity, and calibration, which ultimately provides quantitative measurements of the radiation from the plasma. The reliability of the quantified data needs to be established by various checks. The noise estimates also need to be revised and more realistic values need to be established. It is shown that the 2D heat diffusion equation can be used for estimating the power falling on the IRVB foil, even with a significant amount of spatial variation in the thermal diffusivity across the area of the platinum foil found experimentally during foil calibration. The equation for the noise equivalent power density (NEPD) is re-derived to include the errors in the measurement of the thermophysical and the optical properties of the IRVB foil. The theoretical value estimated using this newly derived equation matches closely, within 5.5%, with the mean experimental value. The change in the contribution of each error term of the NEPD equation with rising foil temperature is also studied and the blackbody term is found to dominate the other terms at elevated operating temperatures. The IRVB foil is also sensitive to the charge exchange (CX) neutrals escaping from the plasma. The CX neutral contribution is estimated to be marginally higher than the noise equivalent power (NEP) of the IRVB. It is also established that the radiation measured by the IRVB originates from the impurity line radiation from the plasma and not from the heated divertor tiles. The change in the power density due to noise reduction measures such as data smoothing and averaging is found to be comparable to the IRVB NEPD. The precautions that need to be considered during background subtraction are also discussed with experimental illustrations. Finally, the analysis algorithm with all the improvements is validated and found to reproduce the input power well within 10% accuracy. This article answers many fundamental questions relevant to the IRVB and illustrates the care to be exercised while processing the IRVB data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Threefold reduction of modeled uncertainty in direct radiative effects over biomass burning regions by constraining absorbing aerosols

Absorbing aerosols emitted from biomass burning (BB) greatly affect the radiation balance, cloudiness, and circulation over tropical regions. Assessments of these impacts rely heavily on the modeled aerosol absorption from poorly constrained global models and thus exhibit large uncertainties. By combining the AeroCom model ensemble with satellite and in situ observations, we provide constraints on the aerosol absorption optical depth (AAOD) over the Amazon and Africa. Our approach enables identification of error contributions from emission, lifetime, and MAC (mass absorption coefficient) per model, with MAC and emission dominating the AAOD errors over Amazon and Africa, respectively. In addition to primary emissions, our analysis suggests substantial formation of secondary organic aerosols over the Amazon but not over Africa. Furthermore, we find that differences in direct aerosol radiative effects between models decrease by threefold over the BB source and outflow regions after correcting the identified errors. This highlights the potential to greatly reduce the uncertainty in the most uncertain radiative forcing agent.

09 BIOMASS FUELS↗

On the reduction of occultation light curves

The two basic methods of reducing occultation light curves - curve fitting and inversion - are reviewed and compared. It is shown that the curve fitting methods have severe problems of nonuniqueness. In addition, in the case of occultation curves dominated by spikes, it is not clear that such solutions are meaningful. The inversion method does not suffer from these drawbacks. Methods of deriving temperature profiles from refractivity profiles are then examined. It is shown that, although the temperature profiles are sensitive to small errors in the refractivity profile, accurate temperatures can be obtained, particularly at the deeper levels of the atmosphere. The ambiguities that arise when the occultation curve straddles the turbopause are briefly discussed.

Wasserman, L.↗

On the improvement of measurement accuracy of retained austenite in steel with X-ray diffraction

Highlights: • Improved procedure to determine austenite in steels with crystallographic texture • Extension to X-ray area detectors • Electropolishing is essential to get correct results. - Abstract: An improved measurement scheme for the determination of the retained austenite fraction with X-ray diffraction is extended to area detectors. The scheme reduces the error due to crystallographic texture in phase analysis of steel by averaging the results of diffraction patterns at different sample positions. The method is based on the standard ASTM E975, but it can be easily extended to other crystal structures, multi-phase materials or X-ray wavelengths. Phase transformation, induced by mechanical sample preparation, may lead to a significant reduction of the retained austenite fraction. Electropolishing before the measurement is beneficial to remove the layer affected by sample preparation.

36 MATERIALS SCIENCE↗

A comprehensive understanding of the efficacy of N-Ring hardening methodologies in SiGe HBTs.

We investigate the efficacy of mitigating radiation-based single event effects (SEE) within circuits incorporating SiGe heterojunction bipolar transistors (HBTs) built with an N-Ring, a transistor-level layout-based radiation hardened by design (RHBD) technique. Previous work of single-device ion-beam induced charge collection (IBICC) studies has demonstrated significant reductions in peak collector charge collection and sensitive area for charge collection; however, few circuit studies using this technique have been performed. Transient studies performed with Sandia National Laboratory's (SNL) 36 MeV 16O microbeam on voltage references built with N-Ring SiGe HBTs have shown mixed results, with reductions in the number of large voltage disruptions in addition to new sensitive areas of low-level output voltage disturbances. Similar discrepancies between device-level IBICC results and circuit measurements are found for the case of digital shift registers implemented with N-Ring SiGe HBTs irradiated in a broadbeam environment at Texas A&M's Cyclotron Institute. The error cross-section curve of the N-Ring based register is found to be larger at larger ion LETs than the standard SiGe register, which is clearly counter-intuitive. We have worked to resolve the discrepancy between the measured circuit results and the device-level IBICC measurements, by re-measuring single-device N-Ring SiGe HBTs using a time-resolved ion beam induced charge (TRIBIC) set-up that allows direct capture of nodal transients. Coupling these measurements with full 3-D TCAD simulations provides complete insight into the origin of transient currents in an N-Ring SiGe HBT. The detailed structure of these transients and their bias dependencies are discussed, together with the ramifications for the design of space-borne analog and digital circuits using SiGe HBTs.

42 ENGINEERING↗

Design of and data reduction from compact Thomson parabola spectrometers

Thomson parabola spectrometers are used to characterize MeV ion beams produced in high intensity laser interactions. These spectrometers disperse multiple ion species according to their charge to mass ratio through the use of parallel electric and magnetic fields. Analytical solutions for ion deflection in electric and magnetic fields have been used to extract ion spectra with the assumption that fringing effects are negligible. Experimental space restrictions and dynamic range requirements necessitate designs that stress the analytical assumptions. Depending on design parameters, the error in the analytical assumption can be comparable to the energy resolution. Estimates are provided to approximate the error on the total ion deflection. A method for modeling ion trajectories including fringing effects is presented using software freely available or in common use. The magnetostatic fields are modeled in 3D, including material properties of nearby magnetic materials using RADIA. Electrostatic fields are modeled in 2D for a spectrometer implementing angled plates using the partial differential equation toolbox in MATLAB. Using these models to calculate the ion trajectory allows for analysis of a Thomson parabola spectrometer with an arbitrary field configuration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗