Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Decline in Tested and Self-Reported Cognitive Functioning After Prophylactic Cranial Irradiation for Lung Cancer: Pooled Secondary Analysis of Radiation Therapy Oncology Group Randomized Trials 0212 and 0214

Purpose: To assess the impact of prophylactic cranial irradiation (PCI) on self-reported cognitive functioning (SRCF), a functional scale on the European Organization for Research and Treatment of Cancer Core Quality of Life Questionnaire (EORTC QLQ-C30). Methods and Materials: Radiation Therapy Oncology Group (RTOG) protocol 0214 randomized patients with locally advanced non-small cell lung cancer to PCI or observation; RTOG 0212 randomized patients with limited-disease small cell lung cancer to high- or standard-dose PCI. In both trials, Hopkins Verbal Learning Test (HVLT)-Recall and -Delayed Recall and SRCF were assessed at baseline (after locoregional therapy but before PCI or observation) and at 6 and 12 months. Patients developing brain relapse before follow-up evaluation were excluded. Decline was defined using the reliable change index method and correlated with receipt of PCI versus observation using logistic regression modeling. Fisher's exact test correlated decline in SRCF with HVLT decline. Results: Of the eligible patients pooled from RTOG 0212 and RTOG 0214, 410 (93%) receiving PCI and 173 (96%) undergoing observation completed baseline HVLT or EORTC QLQ-C30 testing and were included in this analysis. Prophylactic cranial irradiation was associated with a higher risk of decline in SRCF at 6 months (odds ratio 3.60, 95% confidence interval 2.34-6.37, P<.0001) and 12 months (odds ratio 3.44, 95% confidence interval 1.84-6.44, P<.0001). Decline on HVLT-Recall at 6 and 12 months was also associated with PCI (P=.002 and P=.002, respectively) but was not closely correlated with decline in SRCF at the same time points (P=.05 and P=.86, respectively). Conclusions: In lung cancer patients who do not develop brain relapse, PCI is associated with decline in HVLT-tested and self-reported cognitive functioning. Decline in HVLT and decline in SRCF are not closely correlated, suggesting that they may represent distinct elements of the cognitive spectrum.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Grid Cyber-Security Strategy in an Attacker-Defender Model

The progression of cyber-attacks on the cyber-physical system is analyzed by the Probabilistic, Learning Attacker, and Dynamic Defender (PLADD) model. Although our research does apply to all cyber-physical systems, we focus on power grid infrastructure. The PLADD model evaluates the effectiveness of moving target defense (MTD) techniques. We consider the power grid attack scenarios in the AND configurations and OR configurations. In addition, we consider, for the first time ever, power grid attack scenarios involving both AND configurations and OR configurations simultaneously. Cyber-security managers can use the strategy introduced in this manuscript to optimize their defense strategies. Specifically, our research provides insight into when to reset access controls (such as passwords, internet protocol addresses, and session keys), to minimize the probability of a successful attack. Our mathematical proof for the OR configuration of multiple PLADD games shows that it is best if all access controls are reset simultaneously. For the AND configuration, our mathematical proof shows that it is best (in terms of minimizing the attacker's average probability of success) that the resets are equally spaced apart. We introduce a novel concept called hierarchical parallel PLADD system to cover additional attack scenarios that require combinations of AND and OR configurations.

97 MATHEMATICS AND COMPUTING↗

An empirical evaluation of graphical interfaces to support flight planning

Whether optimization techniques or expert systems technologies are used, the underlying inference processes and the model or knowledge base for a computerized problem-solving system are likely to be incomplete for any given complex, real-world task. To deal with the resultant brittleness, it has been suggested that 'cooperative' rather than 'automated' problem-solving systems be designed. Such cooperative systems are proposed to explicitly enhance the collaboration of people and the computer system when working in partnership to solve problems. This study evaluates the impact of alternative design concepts on the performance of airline pilots interacting with such a cooperative system designed to support enroute flight planning. Thirty pilots were studied using three different versions of the system. The results clearly demonstrate that different system design concepts can strongly influence the cognitive processes of users. Indeed, one of the designs studied caused four times as many pilots to accept a poor flight amendment. Based on think-aloud protocols, cognitive models are proposed to account for how features of the computer system interacted with specific types of scenarios to influence exploration and decision-making by the pilots. The results are then used to develop recommendations for guiding the design of cooperative systems.

Smith, Philip J.↗

Frequency Spectrum for New Aviation Data Links: Initial Study Results

We describe results from an initial study to assess the suitability of various spectral bands for supporting the deployment of new aviation data links (ADL). The study focused on systems and spectral bands that can deliver VHF data link (VDL)-or-higher data rates in a two-way communication setting, including air-ground, ground-air, and air-air modes of operation. In the first part of our paper, we briefly discuss the current situation regarding communications, navigation, and surveillance (CNS) links and existing spectrum, and the well-known need for new aviation data links. We next provide an overview of related systems, and discuss key factors involved in the use of spectrum in various bands for any future integrated CNS data link, addressing primarily the lower few layers of the communications protocol stack. Desired attributes of a new ADL system are discussed, and the beneficial aspects of a particular transmission technique spread spectrum are summarized. We also provide a short list of several example potential spectral regions, and note that while none of the existing systems will likely meet the full range of desired features of a new ADL, several systems and spectral regions offer promise in terms of one or more characteristics. A detailed discussion and evaluation of these spectral regions is proposed as future work. We include a few brief examples to illustrate initial technical results regarding spread spectrum overlay, also a subject for future work.

Matolak, David W.↗

Effects of Acclimation on Poststocking Dispersal and Physiological Condition of Age-1 Pallid Sturgeon

A propagation program for pallid sturgeon Scaphirhynchus albus in the upper Missouri River was implemented by the U. S. Fish and Wildlife Service in 1997. Preliminary research indicated that many hatchery-reared pallid sturgeon were experiencing significant downstream poststocking dispersal, negatively affecting their recruitment. Therefore, the objective of this study was to evaluate the effects of acclimation to flow and site-specific physicochemical water conditions on poststocking dispersal and physiological condition of age-1 pallid sturgeon. Fish from three acclimation treatments were radio-tagged, released at two locations (Missouri River and Marias River), and monitored using passive telemetry stations. Marias treatment was acclimated to flow and site-specific physicochemical conditions, Bozeman treatment was acclimated to flow only, and traditional treatment had no acclimation (reared under traditional protocol). During both years fish released in the Missouri River dispersed less than fish released in the Marias River. In 2005, Marias treatment dispersed less and nearly twice as many fish remained in the Missouri River reach than traditional treatment. In 2006, pallid sturgeon dispersed similarly among treatments and fish remaining in the Missouri River reach were similar among all treatments. Differences in poststocking dispersal between years may be related to fin curl. Fin curl was present in all fish in 2005 and 27% of the fish in 2006. Pallid sturgeon from all treatments in both years had a greater affinity for the lower reaches of the Missouri River than the upper reaches. Thus, habitat at release site influenced poststocking dispersal more than acclimation treatment. No difference was observed in relative growth rate among treatments in 2006. However, acclimation to flow (i.e., exercise conditioning) may reduce liver fat content. Acclimation conditions used in this study may not benefit pallid sturgeon unless physiological maladies are present. Further, natural resource agencies need to consider stocking location carefully to reduce poststocking dispersal.

54 ENVIRONMENTAL SCIENCES↗

SU-F-BRA-14: Optimization of Dosimetric Guidelines for Accelerated Partial Breast Irradiation (APBI) Using the Strut-Adjusted Volume Implant (SAVI)

Purpose: Treatment planning guidelines for accelerated partial breast irradiation (ABPI) using the strut-adjusted volume implant (SAVI) are inconsistent between the manufacturer and NSABP B-39/RTOG 0413 protocol. Furthermore neither set of guidelines accounts for different applicator sizes. The purpose of this work is to establish guidelines specific to the SAVI that are based on clinically achievable dose distributions. Methods: Sixty-two consecutive patients were implanted with a SAVI and prescribed to receive 34 Gy in 10 fractions twice daily using high dose-rate (HDR) Ir-192 brachytherapy. The target (PTV-EVAL) was defined per NSABP. The treatments were planned and evaluated using a combination of dosimetric planning goals provided by the NSABP, the manufacturer, and our prior clinical experience. Parameters evaluated included maximum doses to skin and ribs, and volumes of PTV-EVAL receiving 90%, 95%, 100%, 150%, and 200% of the prescription (V90, etc). All target parameters were evaluated for correlation with device size using the Pearson correlation coefficient. Revised dosimetric guidelines for target coverage and heterogeneity were determined from this population. Results: Revised guidelines for minimum target coverage (ideal in parentheses): V90≥95%(97%), V95≥90%(95%), V100≥88%(91%). The only dosimetric parameters that were significantly correlated (p<0.05) with device size were V150 and V200. Heterogeneity criteria were revised for the 6–1 Mini/6-1 applicators to V150≤30cc and V200≤15cc, and unchanged for the other sizes. Re-evaluation of patient plans showed 90% (56/62) met the revised minimum guidelines and 76% (47/62) met the ideal guidelines. All and 56/62 patients met our institutional guidelines for maximum skin and rib dose, respectively. Conclusions: We have optimized dosimetric guidelines for the SAVI applicators, and found that implementation of these revised guidelines for SAVI treatment planning yielded target coverage exceeding that required by existing guidelines while preserving heterogeneity constraints and minimizing dose to organs at risk.

60 APPLIED LIFE SCIENCES↗

AMIP Simulation with the CAM4 Spectral Element Dynamical Core

We evaluate the climate produced by the Community Earth System Model, version 1, running with the new spectral-element atmospheric dynamical core option. The spectral-element method is congured to use a cubed-sphere grid, providing quasi-uniform resolution over the sphere, increased parallel scalability and removing the need for polar filters. It uses a fourth order accurate spatial discretization which locally conserves mass and moist total energy. Using the Atmosphere Model Intercomparison Project protocol, we compare the results from the spectral-element dy- namical core with those produced by the default nite-volume dynamical core and with observations.

CAM-SE↗

Effect of a central redistribution of fluid volume on response to lower-body negative pressure

Cardiovascular responses to lower-body negative pressure (LBNP) were studied following 1 hour of 6-deg head-down tilt to determine whether a redistribution of blood volume toward the central circulation modifies the subsequent response to orthostatic stress. Responses of 12 men, ages 30-39 years, were evaluated by electrocardiography, impedance cardiography, sphygmomanometry, and measurement of calf circumference. During the LBNP that followed head-down tilt, as compared with control LBNP (no preceding head-down tilt) subjects, had smaller stroke volume and cardiac output, greater total peripheral resistance, and less calf enlargement. These differences reflect differences in the variables immediately preceding LBNP. Magnitudes of the responses from pre-LBNP to each pressure stage of the LBNP procedure did not differ between protocols. Mean and diastolic arterial pressures were slightly elevated after LBNP-control, but they fell slightly during LBNP post-tilt.

Tomaselli, Clare M.↗

Proceedings of the Second NASA Formal Methods Symposium

This publication contains the proceedings of the Second NASA Formal Methods Symposium sponsored by the National Aeronautics and Space Administration and held in Washington D.C. April 13-15, 2010. Topics covered include: Decision Engines for Software Analysis using Satisfiability Modulo Theories Solvers; Verification and Validation of Flight-Critical Systems; Formal Methods at Intel -- An Overview; Automatic Review of Abstract State Machines by Meta Property Verification; Hardware-independent Proofs of Numerical Programs; Slice-based Formal Specification Measures -- Mapping Coupling and Cohesion Measures to Formal Z; How Formal Methods Impels Discovery: A Short History of an Air Traffic Management Project; A Machine-Checked Proof of A State-Space Construction Algorithm; Automated Assume-Guarantee Reasoning for Omega-Regular Systems and Specifications; Modeling Regular Replacement for String Constraint Solving; Using Integer Clocks to Verify the Timing-Sync Sensor Network Protocol; Can Regulatory Bodies Expect Efficient Help from Formal Methods?; Synthesis of Greedy Algorithms Using Dominance Relations; A New Method for Incremental Testing of Finite State Machines; Verification of Faulty Message Passing Systems with Continuous State Space in PVS; Phase Two Feasibility Study for Software Safety Requirements Analysis Using Model Checking; A Prototype Embedding of Bluespec System Verilog in the PVS Theorem Prover; SimCheck: An Expressive Type System for Simulink; Coverage Metrics for Requirements-Based Testing: Evaluation of Effectiveness; Software Model Checking of ARINC-653 Flight Code with MCP; Evaluation of a Guideline by Formal Modelling of Cruise Control System in Event-B; Formal Verification of Large Software Systems; Symbolic Computation of Strongly Connected Components Using Saturation; Towards the Formal Verification of a Distributed Real-Time Automotive System; Slicing AADL Specifications for Model Checking; Model Checking with Edge-valued Decision Diagrams; and Data-flow based Model Analysis.

Munoz, Cesar↗

An evaluation of experimental decadal predictions using CCSM4

This study assesses retrospective decadal prediction skill of sea surface temperature (SST) variability in initialized climate prediction experiments with the Community Climate System Model version 4 (CCSM4). Ensemble forecasts initialized with two different historical ocean and sea-ice states are evaluated and compared to an ensemble of uninitialized coupled simulations. Both experiments are subject to identical twentieth century historical radiative forcings. Each forecast consists of a 10-member ensemble integrated over a 10-year period. One set of historical ocean and sea-ice conditions used for initialization comes from a forced ocean-ice simulation driven by the Coordinated Ocean-ice Reference Experiments interannually varying atmospheric dataset. Following the Coordinated Model Intercomparison Project version 5 (CMIP5) protocol, these forecasts are initialized every 5 years from 1961 to 1996, and every year from 2000 to 2006. A second set of initial conditions comes from historical ocean state estimates obtained through the assimilation of in-situ temperature and salinity data into the CCSM4 ocean model. These forecasts are only available over a limited subset of the CMIP5 recommended start dates. Both methods result in retrospective SST prediction skill over broad regions of the Indian Ocean, western Pacific Ocean and North Atlantic Ocean that are significantly better than reference skill levels from a spatio-temporal auto-regressive statistical model of SST. However the subpolar gyre region of the North Atlantic stands out as the only region where the CCSM4 initialized predictions outperform uninitialized simulations. Some features of the ocean state estimates used for initialization and their impact on the forecasts are discussed.

Meteorology & Atmospheric Sciences↗

Machine learning prediction on the fractional free volume of polymer membranes

Fractional free volume (FFV) characterizes the microstructural level features of polymers and affects their properties including thermal, mechanical, and separation performance. Experimental measurements and theoretical analyses have been used to quantify the FFV of polymers, but challenges remain because of their limitations. Experimental measurements are laborious and based on semi empirical equations, while Bondi’s group contribution theory involves ambiguities like the determination of van der Waals volume and the choice of factor values in the theoretical equation. To efficiently evaluate the FFV of polymers, this study utilizes high-throughput molecular dynamics (MD) simulations to build a large dataset regarding polymer’s FFV. Based on this large dataset, we further build machine learning (ML) models to establish the composition-structure relation. Inspired by group contribution theory which correlates polymer’s functional groups to FFV, our ML models correlate polymer’s substructures or physico-chemical indexes to FFV. Here, our study first benchmarks the MD simulation protocol to obtain reliable FFV of polymers and then carries out high-throughput MD simulations for more than 6,500 homopolymers and 1,400 polyamides. Such a large and diverse dataset makes the well-trained ML models more generalizable, compared with the group contribution theory. The efficiency of a feed forward neural network model is further demonstrated by applying it to a hypothetical polyimide dataset of more than 8 million chemical structures. The predicted FFVs of hypothetical polyimides are further validated by MD simulations. The obtained FFVs of the 8 million polymers, plus their previously reported gas separation performances, demonstrate the promising capability of ML virtual screening for the discovery of polymer membranes with exceptional permeability/selectivity.

36 MATERIALS SCIENCE↗

TH-E-17A-07: Improved Cine Four-Dimensional Computed Tomography (4D CT) Acquisition and Processing Method

Purpose: Artifacts arising from the 4D CT acquisition and post-processing methods add systematic uncertainty to the treatment planning process. We propose an alternate cine 4D CT acquisition and post-processing method to consistently reduce artifacts, and explore patient parameters indicative of image quality. Methods: In an IRB-approved protocol, 18 patients with primary thoracic malignancies received a standard cine 4D CT acquisition followed by an oversampling 4D CT that doubled the number of images acquired. A second cohort of 10 patients received the clinical 4D CT plus 3 oversampling scans for intra-fraction reproducibility. The clinical acquisitions were processed by the standard phase sorting method. The oversampling acquisitions were processed using Dijkstras algorithm to optimize an artifact metric over available image data. Image quality was evaluated with a one-way mixed ANOVA model using a correlation-based artifact metric calculated from the final 4D CT image sets. Spearman correlations and a linear mixed model tested the association between breathing parameters, patient characteristics, and image quality. Results: The oversampling 4D CT scans reduced artifact presence significantly by 27% and 28%, for the first cohort and second cohort respectively. From cohort 2, the inter-replicate deviation for the oversampling method was within approximately 13% of the cross scan average at the 0.05 significance level. Artifact presence for both clinical and oversampling methods was significantly correlated with breathing period (ρ=0.407, p-value<0.032 clinical, ρ=0.296, p-value<0.041 oversampling). Artifact presence in the oversampling method was significantly correlated with amount of data acquired, (ρ=-0.335, p-value<0.02) indicating decreased artifact presence with increased breathing cycles per scan location. Conclusion: The 4D CT oversampling acquisition with optimized sorting reduced artifact presence significantly and reproducibly compared to the phase-sorted clinical acquisition.

60 APPLIED LIFE SCIENCES↗

SU-E-T-259: Development of a Primary Standard for LDR Brachytherapy

Purpose: The National Research Council initiated a program in 2012 to develop a primary standard to calibrate I-125 and Pd-103 sources used for LDR brachytherapy and disseminate this through calibration services to Canadian users. This will simplify procedures as Canadian cancer centres currently have to ship instruments to the US. Methods: The standard is based on a commercial version of the wide-angle free air chamber (WAFAC) pioneered by NIST. Significant enhancements were implemented to improve signal-to-noise and measurement reproducibility and eliminate electric field effects. Validation of this ionization chamber was then carried out in a low-energy X -ray beam (∼ 31 keV) where the dose rate had been previously established using the existing NRC primary standard free-air chamber. As a final component of this initial testing, measurements were made with a set of I-125 seeds (with air kerma strength traceable to NIST). Results: Excellent agreement of the two NRC free-air chambers was obtained within the combined standard uncertainty of 0.5 %. However, it was found that the WAFAC response is very sensitive to the beam geometry (distance from the source, diameter of the beam-defining aperture, etc) and Monte Carlo calculations, carried out to evaluate these geometry corrections, have confirmed the experimental results. The results for the seed measurements indicated a precision of better than 1 % is achievable for a reasonable acquisition time and the air kerma strength agreed with the manufacturer (NIST-traceable) value within 2 %. Conclusion: The prototype primary standard for LDR brachytherapy has met accuracy target of 3 % for the determination of air kerma strength. Work is ongoing to refine operation of the device and develop the calibration protocol for clinical users, with an anticipated launch of a calibration service in late 2015.

60 APPLIED LIFE SCIENCES↗

Modeling Large-Scale Slim Fly Networks Using Parallel Discrete-Event Simulation

As supercomputers approach exascale performance, the increased number of processors translates to an increased demand on the underlying network interconnect. We present that the slim fly network topology, a new low-diameter, low-latency, and low-cost interconnection network, is gaining interest as one possible solution for next-generation supercomputing interconnect systems. In this article, we present a high-fidelity slim fly packet-level model leveraging the Rensselaer Optimistic Simulation System (ROSS) and Co-Design of Exascale Storage (CODES) frameworks. We validate the model with published work before scaling the network size up to an unprecedented 1 million compute nodes and confirming that the slim fly observes peak network throughput at extreme scale. In addition to synthetic workloads, we evaluate large-scale slim fly models with real communication workloads from applications in the Design Forward program with over 110,000 MPI processes. We show strong scaling of the slim fly model on an Intel cluster achieving a peak network packet transfer rate of 2.3 million packets per second and processing over 7 billion discrete events using 128 MPI tasks. Enabled by the strong performance capabilities of the model, we perform a detailed application trace and routing protocol performance study. Lastly, through analysis of metrics such as packet latency, hop count, and congestion, we find that the slim fly network is able to leverage simple minimal routing and achieve the same performance as more complex adaptive routing for tested DOE benchmark applications.

97 MATHEMATICS AND COMPUTING↗

The effects of deuterium on static posture control

A significant operational problem impacting upon the Space Shuttle program involves the astronaut's ability to safely egress from the Orbiter during an emergency situation. Following space flight, astronauts display significant movement problems. One variable which may contribute to increased movement ataxia is deuterium (D2O). Deuterium is present in low levels within the Orbiter's water supply but may accumulate to significant physiological levels during lengthy missions. Deuterium was linked to a number of negative physiological responses, including motion sickness, decreased metabolism, and slowing of neural conduction velocity. The effects of D2O on static postural control in response to a range of dosage levels were investigated. Nine sugjects were divided into three groups of three subjects each. The groups were divided into a low, medium, and a high D2O dosage group. The subjects static posture was assessed with the use of the EquiTest systems, a commercially available postural control evaluation system featuring movable force plates and a visual surround that can be servoed to the subject's sway. In addition to the force plate information, data about the degree of subject sway about the hips and shoulders was obtained. Additionally, surface electromyographic (EMG) data from the selected lower limb muscles were collected along with saliva samples used to determine the amount of deuterium enrichment following D2O ingestion. Two baseline testing sessions were performed using the EquiTest testing protocol prior to ingestion of the D2O. Thirty minutes after dosing, subjects again performed the tests. Two more post-dosing tests were run with an interest interval of one hour. Preliminary data anlaysis indicates that only subjects in the igh dose group displayed any significant static postural problems. Future analyses of the sway and EMG is expected to reveal significant variations in the subject's postural control strategy following D2O dosing. While functionally significant static postural problems were not commonly observed, subjects in both the medium and high dosage groups displayed significant, and in some cases, severe voluntary movement problems.

Layne, Charles S.↗

GLOBE Aerosol Field Campaign - U.S. Pilot Study 2016

During the spring of 2016, from April 4 - May 27, sixteen GLOBE schools participated in the GLOBE Aerosol Field Campaign - U.S. Pilot Study. Thirteen teachers from these schools had previously participated in the NASA LEARN program (Long-term Experience in Authentic Research with NASA) where they were GLOBE trained in Atmosphere protocols, and engaged in 1-3 years of research under the mentorship of NASA scientists. Each school was loaned two aerosol instruments for the Campaign duration, either 2 GLOBE sun photometers, 2 Calitoo sun photometers, or 1 of each. This allowed for students to make measurements side-by-side and in the case of the Calitoos, to compare AOT results immediately with each other for better consistency in data collection. Additionally, as part of the Field Campaign evaluation, multiple instruments allow for an assessment of the ease of use of each instrument for grade level of students, whether in middle school or high school. Before the Campaign, all GLOBE and Calitoo instruments were 'checked out' against an AERONET, then checked again upon return after the Campaign. By examining all data, before, during and after the Campaign, this gives an indication of instrument performance and proficiency obtained by the students. Support was provided to each teacher and their students at the level requested, via email, phone or video conferencing.

Pippin, Margaret↗

Impact of SPECT corrections on 3D-dosimetry for liver transarterial radioembolization using the patient relative calibration methodology

Purpose: Many centers aim to plan liver transarterial radioembolization (TARE) with dosimetry, even without CT-based attenuation correction (AC), or with unoptimized scatter correction (SC) methods. This work investigates the impact of presence vs absence of such corrections, and limited spatial resolution, on 3D dosimetry for TARE. Methods: Three voxelized phantoms were derived from CT images of real patients with different body sizes. Simulations of {sup 99m}Tc-SPECT projections were performed with the SIMIND code, assuming three activity distributions in the liver: uniform, inside a “liver’s segment,” or distributing multiple uptaking nodules (“nonuniform liver”), with a tumoral liver/healthy parenchyma ratio of 5:1. Projection data were reconstructed by a commercial workstation, with OSEM protocol not specifically optimized for dosimetry (spatial resolution of 12.6 mm), with/without SC (optimized, or with parameters predefined by the manufacturer; dual energy window), and with/without AC. Activity in voxels was calculated by a relative calibration, assuming identical microspheres and {sup 99m}Tc-SPECT counts spatial distribution. 3D dose distributions were calculated by convolution with {sup 90}Y voxel S-values, assuming permanent trapping of microspheres. Cumulative dose-volume histograms in lesions and healthy parenchyma from different reconstructions were compared with those obtained from the reference biodistribution (the “gold standard,” GS), assessing differences for D95%, D70%, and D50% (i.e., minimum value of the absorbed dose to a percentage of the irradiated volume). γ tool analysis with tolerance of 3%/13 mm was used to evaluate the agreement between GS and simulated cases. The influence of deep-breathing was studied, blurring the reference biodistributions with a 3D anisotropic gaussian kernel, and performing the simulations once again. Results: Differences of the dosimetric indicators were noticeable in some cases, always negative for lesions and distributed around zero for parenchyma. Application of AC and SC reduced systematically the differences for lesions by 5%–14% for a liver segment, and by 7%–12% for a nonuniform liver. For parenchyma, the data trend was less clear, but the overall range of variability passed from −10%/40% for a liver segment, and −10%/20% for a nonuniform liver, to −13%/6% in both cases. Applying AC, SC with preset parameters gave similar results to optimized SC, as confirmed by γ tool analysis. Moreover, γ analysis confirmed that solely AC and SC are not sufficient to obtain accurate 3D dose distribution. With breathing, the accuracy worsened severely for all dosimetric indicators, above all for lesions: with AC and optimized SC, −38%/−13% in liver’s segment, −61%/−40% in the nonuniform liver. For parenchyma, D50% resulted always less sensitive to breathing and sub-optimal correction methods (difference overall range: −7%/13%). Conclusions: Reconstruction protocol optimization, AC, SC, PVE and respiratory motion corrections should be implemented to obtain the best possible dosimetric accuracy. On the other side, thanks to the relative calibration, D50% inaccuracy for the healthy parenchyma from absence of AC was less than expected, while the optimization of SC was scarcely influent. The relative calibration therefore allows to perform TARE planning, basing on D50% for the healthy parenchyma, even without AC or with suboptimal corrections, rather than rely on nondosimetric methods.

60 APPLIED LIFE SCIENCES↗

Development of Sub-optimal Airway Protocols for the International Space Station (ISS) by the Medical Operation Support Team (MOST)

Airway management techniques are necessary to establish and maintain a patent airway while treating a patient undergoing respiratory distress. There are situations where such settings are suboptimal, thus causing the caregiver to adapt to these suboptimal conditions. Such occurrences are no exception aboard the International Space Station (ISS). As a result, the NASA flight surgeon (FS) and NASA astronaut cohorts must be ready to adapt their optimal airway management techniques for suboptimal situations. Based on previous work conducted by the Medical Operation Support Team (MOST) and other investigators, the MOST had members of both the FS and astronaut cohorts evaluate two oral airway insertion techniques for the Intubating Laryngeal Mask Airway (ILMA) to determine whether either technique is sufficient to perform in suboptimal conditions within a microgravity environment. Methods All experiments were conducted in a simulated microgravity environment provided by parabolic flight aboard DC-9 aircraft. Each participant acted as a caregiver and was directed to attempt both suboptimal ILMA insertion techniques following a preflight instruction session on the day of the flight and a demonstration of the technique by an anesthesiologist physician in the simulated microgravity environment aboard the aircraft. Results Fourteen participants conducted 46 trials of the suboptimal ILMA insertion techniques. Overall, 43 of 46 trials (94%) conducted were properly performed based on criteria developed by the MOST and other investigators. Discussion The study demonstrated the use of airway management techniques in suboptimal conditions relating to space flight. Use of these techniques will provide a crew with options for using the ILMA to manage airway issues aboard the ISS. Although it is understood that the optimal method for patient care during space flight is to have both patient and caregiver restrained, these techniques provide a needed backup should conditions not present themselves in an ideal manner.

Polk, James D.↗