Search NASA⌕ Search

SEARCH · Search NASA

Results for “flow test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Water and Ammonia Desorption from 5A Zeolite

The objective of this project is to demonstrate the adsorption and desorption characteristics of water and ammonia on 5A zeolite during regeneration conditions. As discussed in literature, zeolite material is a crystalline hydrated aluminosilicate material. Zeolites have high cation exchange ability and are commonly used as adsorbents in separation and purification processes. The property of uniformly sized pores allows zeolites to selectively separate gases. Because they have varying ion selectivity, there is competitive adsorption in a multicomponent mixture. 5A zeolite has a uniform pore diameter of 5 Angstroms. Water and ammonia are miscible components with similar molecular weights and size. This makes distinguishing the two compounds difficult using mass spectrometry. In a previous study, it was shown that water tends to desorb from 5A zeolite from 40 deg. C to 353 deg. C with peaks at 177 deg. C and 244 deg. C, while ammonia tends to desorb from 300 deg. C to 580 deg. C with a peak at 436 deg. C as determined using a Micromeritics AutoChem 2920 Instrument. The one drawback of using a Micromeritics Instrument is that only a few milligrams of sample material can be used. Bench scale tests can better demonstrate desorption characteristics of water and ammonia during regeneration from 5A zeolite material. Water in argon carrier gas and ammonia in hydrogen carrier gas will be tested separately, then a mixture of the two will be tested. Initial bake-out conditions: hydrogen carrier gas, slowly raise temp to approximately 450 deg. C until desired moisture content <100 ppm is achieved. Water loading: argon carrier gas through bubbler until breach is observed using the residual gas analyzer (RGA). Ammonia loading: hydrogen carrier gas through system until breach is observed using RGA. Regeneration conditions: hydrogen carrier gas, raise temp to approximately 300 deg. C, then slowly to 450 deg. C. Observe signals on RGA. Weigh samples between tests and integrate RGA signals. Accomplishments: Developed work control documentation and completed safety related requirements; Flow sheet and test system development; Initial bake-out of first sample. Testing will determine if regenerating zeolite material can be safely accomplished by high-temperature bake-out to remove ammonia. If unsuccessful, ammonia would only be removed at the end of life.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Embedded function methods for compressible high speed turbulent flow

Fundamental issues relating to compressible turbulent flow are addressed. The focus has been on developing methods and testing concepts for attached flows rather than trying to force a conventional law of the wall into a zone of backflow. Although the dynamics of the near-wall flow in an attached turbulent boundary layer are relatively well documented, the dynamical features of a zone of reversed turbulent flow are not, nor are they well understood. Incompressibility introduces effects and issues that have been dealt with only marginally in the literature, therefore, the present work has been focussed on attached high-speed flows. The wall function method has been extended up through the supersonic to hypersonic speeds. Algorithms have been successfully introduced into the code that calculates the flow all the way to the wall, and testing is being carried out for progressively more complex flow situations.

Walker, J. D. A.↗

FY2017 ILAW Glass Corrosion Testing with the Single-Pass Flow-Through Method

The inventory of immobilized low-activity waste (ILAW) produced at the Hanford Tank Waste Treatment and Immobilization Plant (WTP) will be disposed of at the near-surface, on-site Integrated Disposal Facility (IDF). When groundwater comes into contact with the waste form, the glass will corrode and radionuclides will be released into the near-field environment. Because the release of the radionuclides is dependent on the dissolution rate of the glass, it is important that the performance assessment (PA) model accounts for the dissolution rate of the glass as a function of various conditions. To accomplish this, an IDF PA glass dissolution model based on Transition State Theory (TST) can be employed. The model is able to account for changes in temperature, exposed surface area, and pH of the contacting solution as well as the effect of silicon solution concentrations, specifically the activity of orthosilicic acid (H4SiO4), whose concentration is directly linked to the glass dissolution rate. In addition, the IDF PA model accounts for the ion exchange process. The effect of temperature, pH, H4SiO4 activity, and the rate of ion exchange can be parameterized and implemented directly into the PA rate model. The rate model parameters are derived from laboratory tests with the single-pass flow-through (SPFT) method. The provided data can be used by glass researchers to further the understanding of ILAW glass behavior, by IDF PA modelers to use the rate model parameters in PA modeling efforts, and by Department of Energy (DOE) contractors and decision makers as they assess the IDF PA program.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The EGS Collab Project: Stimulation and Simulation

Development of Enhanced Geothermal Systems (EGS) requires accurate predictions of flow rates and temperatures at production wells over time. The concept of EGS is simple; however, complications from heterogeneity and complexity of fracture pathways may lead to channeling, short-circuiting, and premature thermal breakthrough. In the EGS Collab project, we are establishing a suite of highly monitored and well characterized intermediate-scale (~10-20 m) field test beds along with fracture stimulation and interwell flow tests to better understand processes that control formation of effective subsurface heat exchangers. EGS Collab experiments will provide a means of testing tools and concepts that could later be employed under geothermal reservoir conditions at FORGE or elsewhere. Key to the project is using numerical simulations in the experiment design and interpretation of results. Our tests will be well-controlled, in situ experiments focused on rock fracture behavior and permeability enhancement. Our pre- and post-test modeling results of each field experiment compared with detailed measurements will allow for improved model prediction and validation. We will use comprehensive instrumentation to collect high-quality and high-resolution geophysical and other fracture characterization and fluid flow data. We will analyze these data and compare them with models and field observations to further elucidate the basic relationships between stress, induced seismicity, and permeability enhancement. We will also observe and quantify other key governing parameters that impact permeability, and will attempt to understand how these parameters might change throughout the development and operation of an EGS project with the ultimate goal of enabling commercial viability of EGS. Our first set of experiments will be performed at the Sanford Underground Research Facility (SURF) in South Dakota. Our team is well underway with building the first field experiment test bed planned for this project, which is supported by the US Department of Energy’s Geothermal Technologies Office.

EGS Collab↗

Evaluating Age Effects on HEPA Filter Performance

Nuclear grade high efficiency particulate air (HEPA) filters are routinely employed as the final control element in confinement ventilation systems. The traditional HEPA filter utilizes a pleated filter medium of fibrous glass that has been produced in a manner analogous to manufacturing paper. These filters are the physically weakest element in a containment ventilation system. Containment ventilation systems are designed to condition the air-stream (temperature, relative humidity, moisture, particle size distribution of aerosols, and aerosol concentration) to levels/conditions that fibrous glass HEPA filters can handle. Approximately 6000 nuclear grade HEPA filters are purchased each year for use in the DOE/NNSA complex. Additional filters are purchased for use in commercial nuclear power generation and ventilation systems of other nuclear applications. These filters are designed and tested in accordance with the American Society of Mechanical Engineers (ASME) AG-1 Code Nuclear Air and Gas Treatment. This code establishes design requirements and qualification procedures. Qualification testing of axial flow filters is described in paragraphs 5000 and following of AG-1. The series of qualification tests are intended to describe the operating envelope of HEPA filters and verify the reliability of a filter design. AG-1 qualification also confirms the pedigree of components used in manufacture for that filter design. The collective set of qualification tests establishes the assumed operating envelope for AG-1 filters. The effects of age on HEPA filter performance have been a concern for at least two decades. A combination of physical evaluation of aged filter media and a review of filter failure records resulted in Appendix C of the Nuclear Air Cleaning Handbook (NACH), Determination of HEPA Filter Life. This states that HEPA filters are not to be used beyond 10 years from the date of manufacture. Additionally, filters put into service in locations where they may become wet are to be taken out of service five years from date of manufacture. Filters that have become wet are to be taken out of service immediately. Finally, it should also be pointed out that filters held in Level B storage are subject to the same 10-year service life. Very limited bench-scale testing in the 1990's raised concern that aging HEPA filters do not have the strength to withstand an accident scenario. In May of 1999, the DNFSB released a Technical Report 23 entitled HEPA Filters Used in the Department of Energy's Hazardous Facilities. This report expressed concerns for the potential vulnerability of HEPA filters in vital safety systems. Concerns and uncertainty associated with degradation of HEPA filter performance over time led the DOE sites to limit HEPA filter service life to 10 years from the date of manufacture or five years in cases where filters may become wet. Establishment of a conservative service life needs to be based on data from a structured series of tests comparing the performance envelope of new and aged full-scale filters. A service life that is insufficiently conservative endangers workers and the public. One that is excessively conservative costs can cause hundreds of otherwise unnecessary filter changes. This increases exposure of employees, disrupts facility operations, and increase disposal costs by millions of dollars annually. Conclusive data are needed to resolve uncertainty associated with the damaging effects of aging on durability of HEPA filters. Therefore, this study needs to provide a sufficient body of evidence to allow DOE and site professionals to make prudent decisions. An updated version of ASME AG-1 Section FC included a non-mandatory appendix that would include the DOE guidance for service life of HEPA filters. Balloting of this revision generated significant resistance to inclusion of any kind of service life language citing the lack of supporting experimental data. Efforts to resolve negative votes failed and resistance to acceptance of the language increased. The result has been to not include service language in Section FC and requests to remove it from sections that already include such language. The recent activity of the ASME AG-1 Committee on Nuclear Air and Gas Treatment effectively de-emphasizes following DoE's service life guidelines. The DOE Office of Nuclear Safety under its NSR and D program provided the Mississippi State University Institute for Clean Energy Technology (ICET) finding to initiate a study to determine the effects of aging on AG-1 axial flow filters just prior to actions taken within the AG-1 committee regarding service life. The NSR and D funding facilitated timely development of a national technical working group comprised of members from the regulatory community, DOE complex, and commercial power to resolve uncertainty associated with effects of aging. The Department of Energy Office of Environmental Management (DOE-EM) has been funding the ICET to evaluate the performance envelope for AG-1 HEPA filters. ICET is one of DOE-EM's qualified suppliers. Synergy has been achieved by associating the NSR and D aged filter activities to testing activities evaluating the performance envelopes of separator and separator-less AG-1 HEPA filters funded by DOE-EM. The DOE-EM funded activities establish baseline data for the aged filter study and future EM funding will provide long term support for testing additional aged filters. EM funding of new filters includes analytical evaluation of media tensile strength by thermal analysis to establish baseline values and determine mass loss of moisture resistance and acrylic binders due to use. All of these values can be used for comparison of test results for aged filters. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

FY2016 ILAW Glass Corrosion Testing with the Single-Pass Flow-Through Method

The inventory of immobilized low-activity waste (ILAW) produced at the Hanford Tank Waste Treatment and Immobilization Plant (WTP) will be disposed of at the near-surface, on-site Integrated Disposal Facility (IDF). When groundwater comes into contact with the waste form, the glass will corrode and radionuclides will be released into the near-field environment. Because the release of the radionuclides is dependent on the dissolution rate of the glass, it is important that the performance assessment (PA) model accounts for the dissolution rate of the glass as a function of various chemical conditions. To accomplish this, an IDF PA model based on Transition State Theory (TST) can be employed. The model is able to account for changes in temperature, exposed surface area, and pH of the contacting solution as well as the effect of silicon concentrations in solution, specifically the activity of orthosilicic acid (H4SiO4), whose concentration is directly linked to the glass dissolution rate. In addition, the IDF PA model accounts for the alkali-ion exchange process as sodium is leached from the glass and into solution. The effect of temperature, pH, H4SiO4 activity, and the rate of ion-exchange can be parameterized and implemented directly into the PA rate law model. The rate law parameters are derived from laboratory tests with the single-pass flow-through (SPFT) method. To date, rate law parameters have been determined for seven ILAW glass compositions, thus additional rate law parameters on a wider range of compositions will supplement the existing body of data for PA maintenance activities. The data provided in this report can be used by ILAW glass scientists to further the understanding of ILAW glass behavior, by IDF PA modelers to use the rate law parameters in PA modeling efforts, and by Department of Energy (DOE) contractors and decision makers as they assess the IDF PA program.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preliminary Design of a Distributed Facesheet Acoustic Liner for Broadband Acoustic Attenuation

The purpose of this study is to investigate the acoustic performance of a liner with a distributed facesheet and a uniform depth core for broadband attenuation. The distributed facesheet is comprised of a cluster of three distinct cell resonators of varying hole diameter and porosity replicated over the active liner treatment area. A target frequency range of 1000 to 2000 Hz and an attenuation metric of 10 dB are chosen. An optimizer is used to determine the optimal facesheet designs for flow conditions of Mach 0.0 and Mach 0.3. The samples are tested in the Grazing Flow Impedance Tube at NASA Langley Research Center. The two liners are shown to achieve at least 10 dB attenuation over frequency ranges of 700 and 400 Hz, respectively, when tested at their respective designed flow speeds. This study demonstrate that a distributed facesheet with a uniform depth core can be successfully used to achieve broadband sound absorption.

acoustic liners↗

Performance of the active sidewall boundary-layer removal system for the Langley 0.3-meter Transonic Cryogenic Tunnel

A performance evaluation of an active sidewall boundary-layer removal system for the Langley 0.3-m Transonic Cryogenic Tunnel (TCT) was evaluated in 1988. This system uses a compressor and two throttling digital valves to control the boundary-layer mass flow removal from the tunnel. The compressor operates near the maximum pressure ratio for all conditions. The system uses a surge prevention and flow recirculation scheme. A microprocessor based controller is used to provide the necessary mass flow and compressor pressure ratio control. Initial tests on the system indicated problems in realizing smooth mass flow control while running the compressor at high speed and high pressure ratios. An alternate method has been conceived to realize boundary-layer mass flow control which avoids the recirculation of the compressor mass flow and operation near the compressor surge point. This scheme is based on varying the speed of the compressor for a sufficient pressure ratio to provide needed mass flow removal. The system has a mass flow removal capability of about 10 percent of test section flow at M = 0.3 and 4 percent at M = 0.8. The system performance has been evaluated in the form of the compressor map, and compressor tunnel interface characteristics covering most of the 0.3-m TCT operational envelope.

Balakrishna, S.↗

Wind-tunnel investigation of aerodynamic characteristics and wing pressure distributions of an airplane with variable-sweep wings modified for laminar flow

A wind tunnel test was conducted to evaluate the aerodynamic characteristics and wing pressure distributions of a variable wing sweep aircraft having wing panels that are modified to promote laminar flow. The modified wing section shapes were incorporated over most of the exposed outer wing panel span and were obtained by extending the leading edge and adding thickness to the existing wing upper surface forward of 60 percent chord. Two different wing configurations, one each for Mach numbers 0.7 and 0.8, were tested on the model simultaneously, with one wing configuration on the left side and the other on the right. The tests were conducted at Mach numbers 0.20 to 0.90 for wing sweep angles of 20, 25, 30, and 35 degrees. Longitudinal, lateral and directional aerodynamic characteristics of the modified and baseline configurations, and selected pressure distributions for the modified configurations, are presented in graphical form without analysis. A tabulation of the pressure data for the modified configuration is available as microfiche.

Hallissy, James B.↗

Characteristics of the NASA-Ames Laminar Flow Supersonic Wind Tunnel for Unique Mach 1.6 Transition Studies

Flow quality measurements have been performed in the unique Laminar Flow Supersonic Wind Tunnel (LFSWT) to examine both mean and dynamic characteristics. The intent was to provide the necessary flow information about this ground test facility, to support meaningful transition research at Mach 1.6 and flight unit Reynolds numbers. This paper is intended to assist other experimentalists with similar goals of characterizing low-supersonic test environments. An array of instrumentation has been used to highlight the importance of proper selection of pressure instruments and data acquisition procedures. We conclude that the test section is low-disturbance (based on classical standards of pressure disturbances less than 0.1% with no specified data bandwidth), and has uniform flow. This is confirmation that the quiet design features of the LFSWT are effective. However, characterization of the test section flow over a 0.25k-5Ok bandwidth shows that the disturbance levels can be greater than classical standards particularly for stagnation pressures less than 9.5 psia (0.65 bar) with low stagnation temperatures. Variability of the flow disturbances in the settling chamber and test section is contained in a narrow frequency bandwidth below 5k Hz, which is associated with resonant frequencies from the pressure reduction system. So far, these disturbances have not impacted transition along the tunnel walls or a 10 degrees cone. However, continual vigilance is required to maintain a known low-disturbance environment for transition research in the LFSWT. Furthermore, the formation of standards for flow quality measurements is strongly recommended, so that transition research can be better isolated from tunnel disturbances.

Wolf, Stephen W. D.↗

Effect of several porous casing treatments on stall limit and on overall performance of an axial flow compressor rotor

Several geometrically different porous casings were tested with an axial-flow compressor rotor to determine their effects upon the rotor stall-limit line and overall performance. The tests were conducted using both uniform and nonuniform inlet-flow conditions. The rotor performance with the various casing treatments is compared with that obtained with a solid casing. The ability of the various casing treatments to displace the rotor stall-limit line to lower weight flows was observed. Significant stall-margin increases were obtained with several of the porous casings. Peak efficiencies with two of the porous casings were as high as or slightly higher than that obtained with solid casing.

Osborn, W. M.↗

Flight Services and Aircraft Access: Active Flow Control Vertical Tail and Insect Accretion and Mitigation Flight Test

This document serves as the final report for the Flight Services and Aircraft Access task order NNL14AA57T as part of NASA Environmentally Responsible Aviation (ERA) Project ITD12A+. It includes descriptions of flight test preparations and execution for the Active Flow Control (AFC) Vertical Tail and Insect Accretion and Mitigation (IAM) experiments conducted on the 757 ecoDemonstrator. For the AFC Vertical Tail, this is the culmination of efforts under two task orders. The task order was managed by Boeing Research & Technology and executed by an enterprise-wide Boeing team that included Boeing Research & Technology, Boeing Commercial Airplanes, Boeing Defense and Space and Boeing Test and Evaluation. Boeing BR&T in St. Louis was responsible for overall Boeing project management and coordination with NASA. The 757 flight test asset was provided and managed by the BCA ecoDemonstrator Program, in partnership with Stifel Aircraft Leasing and the TUI Group. With this report, all of the required deliverables related to management of this task order have been met and delivered to NASA as summarized in Table 1. In addition, this task order is part of a broader collaboration between NASA and Boeing.

Whalen, Edward A.↗

Method and apparatus for measuring thermal conductivity of small, highly insulating specimens

A hot plate method and apparatus for the measurement of thermal conductivity combines the following capabilities: 1) measurements of very small specimens; 2) measurements of specimens with thermal conductivity on the same order of that as air; and, 3) the ability to use air as a reference material. Care is taken to ensure that the heat flow through the test specimen is essentially one-dimensional. No attempt is made to use heated guards to minimize the flow of heat from the hot plate to the surroundings. Results indicate that since large correction factors must be applied to account for guard imperfections when specimen dimensions are small, simply measuring and correcting for heat from the heater disc that does not flow into the specimen is preferable. The invention is a hot plate method capable of using air as a standard reference material for the steady-state measurement of the thermal conductivity of very small test samples having thermal conductivity on the order of air.

Miller, Robert A.↗

Six Degrees of Freedom (6DOF) Simulations of Supersonic Fragment Trajectories

In this report a process using existing technologies at Sandia National Laboratories (SNL) to simulate the six degrees-of-freedom (6DOF) trajectories of explosive fragments is described and tested. First, aerodynamic forces and moments as functions of orientation are computed using the SIERRA/Aero supersonic flow solver. The forces and moments are normalized and tabulated in a database. Second, this the aerodynamic coefficient database is imported into a 6DOF rigid body dynamics solver in order to compute the resulting trajectories. The supersonic flow simulations are tested for simple geometries and show good agreement with literature values. The simulation procedure is then demonstrated for an example fragment. The results of the example fragment indicate that the distance traveled in the early ight (from 2.5 km/s until decreasing down to 1 km/s) varies widely depending on the initial orientations. The fragment trajectory distribution and steady tumbling rate is explored. The study indicates that a 6DOF analysis will yield information about a spread of possible trajectories, while using an average drag coefficient can only represent the most likely trajectory.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Predicting equilibrium states with Reynolds stress closures in channel flow and homogeneous shear flow

Turbulent channel flow and homogeneous shear flow have served as basic building block flows for the testing and calibration of Reynolds stress models. A direct theoretical connection is made between homogeneous shear flow in equilibrium and the log-layer of fully-developed turbulent channel flow. It is shown that if a second-order closure model is calibrated to yield good equilibrium values for homogeneous shear flow it will also yield good results for the log-layer of channel flow provided that the Rotta coefficient is not too far removed from one. Most of the commonly used second-order closure models introduce an ad hoc wall reflection term in order to mask deficient predictions for the log-layer of channel flow that arise either from an inaccurate calibration of homogeneous shear flow or from the use of a Rotta coefficient that is too large. Illustrative model calculations are presented to demonstrate this point which has important implications for turbulence modeling.

Abid, R.↗