Search NASA⌕ Search

SEARCH · Search NASA

Results for “iterative method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Activated Corrosion Product Analysis. Analytical Approach.

The presence of activated corrosion products (ACPs) in a water cooling system is a key factor in the licensing of ITER and affects nuclear classification, which governs design and operation. The objective of this study is to develop a method to accurately estimate radionuclide concentrations during ITER operation in support of nuclear classification. A brief overview of the PACTITER numerical code, which is currently used for ACP estimation, is presented. An alternative analytical approach for calculation of ACPs, which can also be used for validation of existing numerical codes, including PACTITER, has been proposed. A continuity equation describing the kinetics of accumulation of radioactive isotopes in a water cooling system in the form of a closed ring has been formulated, taking into account the following processes: production of radioactive elements and their decay, filtration, and ACP accumulation in filter system. Additional work is needed to more accurately assess the ACP inventory in the cooling water system, including more accurate simulation of the Tokamak cooling water system (TCWS) operating cycle and consideration of material corrosion, release, and deposition rates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation of the thermal transport model used for ITER startup scenario predictions with DIII-D experimental data

We are exploring characteristics of ITER startup scenarios in similarity experiments conducted on the DIII-D Tokamak. In these experiments, we have validated scenarios for the ITER current ramp up to full current and developed methods to control the plasma parameters to achieve stability. Predictive simulations of ITER startup using 2D free-boundary equilibrium and 1D transport codes rely on accurate estimates of the electron and ion temperature profiles that determine the electrical conductivity and pressure profiles during the current rise. Here we present results of validation studies that apply the transport model used by the ITER team to DIII-D discharge evolution and comparisons with data from our similarity experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-F-J-111: A Novel Distance-Dose Weighting Method for Label Fusion in Multi- Atlas Segmentation for Prostate Radiation Therapy

Purpose: A novel distance-dose weighting method for label fusion was developed to increase segmentation accuracy in dosimetrically important regions for prostate radiation therapy. Methods: Label fusion as implemented in the original SIMPLE (OS) for multi-atlas segmentation relies iteratively on the majority vote to generate an estimated ground truth and DICE similarity measure to screen candidates. The proposed distance-dose weighting puts more values on dosimetrically important regions when calculating similarity measure. Specifically, we introduced distance-to-dose error (DDE), which converts distance to dosimetric importance, in performance evaluation. The DDE calculates an estimated DE error derived from surface distance differences between the candidate and estimated ground truth label by multiplying a regression coefficient. To determine the coefficient at each simulation point on the rectum, we fitted DE error with respect to simulated voxel shift. The DEs were calculated by the multi-OAR geometry-dosimetry training model previously developed in our research group. Results: For both the OS and the distance-dose weighted SIMPLE (WS) results, the evaluation metrics for twenty patients were calculated using the ground truth segmentation. The mean difference of DICE, Hausdorff distance, and mean absolute distance (MAD) between OS and WS have shown 0, 0.10, and 0.11, respectively. In partial MAD of WS which calculates MAD within a certain PTV expansion voxel distance, the lower MADs were observed at the closer distances from 1 to 8 than those of OS. The DE results showed that the segmentation from WS produced more accurate results than OS. The mean DE error of V75, V70, V65, and V60 were decreased by 1.16%, 1.17%, 1.14%, and 1.12%, respectively. Conclusion: We have demonstrated that the method can increase the segmentation accuracy in rectum regions adjacent to PTV. As a result, segmentation using WS have shown improved dosimetric accuracy than OS. The WS will provide dosimetrically important label selection strategy in multi-atlas segmentation. CPRIT grant RP150485.

60 APPLIED LIFE SCIENCES↗

Stochastic Galerkin methods for the steady-state Navier–Stokes equations

We study the steady-state Navier–Stokes equations in the context of stochastic finite element discretizations. Specifically, we assume that the viscosity is a random field given in the form of a generalized polynomial chaos expansion. For the resulting stochastic problem, we formulate the model and linearization schemes using Picard and Newton iterations in the framework of the stochastic Galerkin method, and we explore properties of the resulting stochastic solutions. We also propose a preconditioner for solving the linear systems of equations arising at each step of the stochastic (Galerkin) nonlinear iteration and demonstrate its effectiveness for solving a set of benchmark problems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiative recombination data for tungsten ions: III. W{sup 14+}–W{sup 23+}

This paper completes the cycle of our calculations of the radiative recombination and photoionization data for tungsten ions. Presented here are the photoionization and radiative recombination cross sections, radiative recombination rate coefficients, and radiated power loss rate coefficients for ten tungsten impurity ions from W{sup 14+} to W{sup 23+}. These data are required in diagnostics and modeling fusion plasmas studied in such devices as ITER, ASDEX Upgrade, and EBIT. Partial photoionization cross sections have been fitted by an analytical expression with five fit parameters tabulated here. Total radiative recombination cross sections are presented in the electron energy range from 1 eV to ∼80 keV. Radiative recombination rates and radiated power loss rates are given in the temperature range from 10{sup 4} K to 10{sup 9} K. Calculations have been performed on the basis of the fully relativistic treatment of photoionization and radiative recombination taking into account all significant multipoles of the radiative field. Electron wave functions have been obtained by the Dirac–Fock method with the proper consideration of the electron exchange. The relativistic Maxwell–Jüttner distribution of continuum electrons has been used in calculations of radiative recombination rates and radiated power loss rates. This decreases values of the rates noticeably at a high temperature as compared to the usual non-relativistic Maxwell–Boltzmann distribution. -- Highlights: •Radiative recombination data for ten tungsten ions W{sup 14+}–W{sup 23+} are presented. •Photoionization cross sections are also given. •Calculations are fully relativistic including all multipoles of the radiative field. •We use the Dirac–Fock method to obtain the electron wave functions. •The data are required for diagnostics and modeling fusion plasmas studied in ITER.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multi-stage preconditioners for thermal–compositional–reactive flow in porous media

We present a family of multi-stage preconditioners for coupled thermal-compositional-reactive reservoir simulation problems. The most common preconditioner used in industrial practice, the Constrained Pressure Residual (CPR) method, was designed for isothermal models and does not offer a specific strategy for the energy equation. For thermal simulations, inadequate treatment of the temperature unknown can cause severe conver-gence degradation. When strong thermal diffusion is present, the energy equation exhibits significant elliptic behavior that cannot be accurately corrected by CPR's second stage. In this work, we use Schur-complement decompositions to extract a temperature subsystem and apply an Algebraic MultiGrid (AMG) approximation as an additional preconditioning stage to improve the treatment of the energy equation. We present results for several two-dimensional hot air injection problems using an extra heavy oil, including challenging reactive In-Situ Combustion (ISC) cases. We show improved performance and robustness across different thermal regimes, from advection dominated (high Péclet number) to diffusion dominated (low Péclet number). The number of linear iterations is reduced by 40–85% compared to standard CPR for both homogeneous and heterogeneous media, and the new methods exhibit almost no sensitivity to the thermal regime.

42 ENGINEERING↗

Gradient Coding With Iterative Block Leverage Score Sampling

Gradient coding is a method for mitigating straggling servers in a centralized computing network that uses erasure-coding techniques to distributively carry out first-order optimization methods. Randomized numerical linear algebra uses randomization to develop improved algorithms for large-scale linear algebra computations. In this study, we propose a method for distributed optimization that combines gradient coding and randomized numerical linear algebra. The proposed method uses a randomized ℓ 2 -subspace embedding and a gradient coding technique to distribute blocks of data to the computational nodes of a centralized network, and at each iteration the central server only requires a small number of computations to obtain the steepest descent update. The novelty of our approach is that the data is replicated according to importance scores, called block leverage scores, in contrast to most gradient coding approaches that uniformly replicate the data blocks. Furthermore, we do not require a decoding step at each iteration, avoiding a bottleneck in previous gradient coding schemes. We show that our approach results in a valid ℓ 2 -subspace embedding, and that our resulting approximation converges to the optimal solution.

97 MATHEMATICS AND COMPUTING↗

Modeling of three-dimensional photonic crystal lasers in a frequency domain: A scattering matrix solution

We derive a light-intensity-dependent dielectric constant for a gain medium based on the conventional rate equation model. A scattering-matrix method in conjunction with an efficient iteration procedure is proposed to simulate photonic crystal lasers (PCLs). The light output vs pumping (L-I) curve, lasing mode profile, and chirping effect of the lasing wavelength {lambda}{sub L} can be calculated. We check our method in a one dimensional distributed Bragg reflector laser and simulate a complex three dimensional woodpile PCL to test the capabilities of our model. We found that PCLs with a more uniform field distribution in the gain media will have higher L-I slope efficiencies as well as more stable lasing wavelengths {lambda}{sub L}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Multiple-Set Overlapping-Domain Decomposed Monte Carlo Synthetic Acceleration Method for Linear Systems

We present a multiple-set overlapping-domain decomposed strategy for parallelizing the Monte Carlo Synthetic Acceleration method. Monte Carlo Synthetic Acceleration methods use the Neumann-Ulam class of Monte Carlo solvers for linear systems to accelerate a fixed-point iteration sequence. Effective parallel algorithms for these methods require the parallelization of the underlying Neumann-Ulam solvers. To do this in a domain decomposed environment, we borrow strategies traditionally implemented in Monte Carlo particle transport to parallelize the problem. The parallel Neumann-Ulam and multiple-set overlapping-domain decomposition algorithms are presented along with parallel scaling data for the resulting implementation using the Titan Cray XK7 machine at Oak Ridge National Laboratory.

Computer Science↗

Discontinuous diffusion synthetic acceleration for S{sub n} transport on 2D arbitrary polygonal meshes

In this paper, a Diffusion Synthetic Acceleration (DSA) technique applied to the S{sub n} radiation transport equation is developed using Piece-Wise Linear Discontinuous (PWLD) finite elements on arbitrary polygonal grids. The discretization of the DSA equations employs an Interior Penalty technique, as is classically done for the stabilization of the diffusion equation using discontinuous finite element approximations. The penalty method yields a system of linear equations that is Symmetric Positive Definite (SPD). Thus, solution techniques such as Preconditioned Conjugate Gradient (PCG) can be effectively employed. Algebraic MultiGrid (AMG) and Symmetric Gauss–Seidel (SGS) are employed as conjugate gradient preconditioners for the DSA system. AMG is shown to be significantly more efficient than SGS. Fourier analyses are carried out and we show that this discontinuous finite element DSA scheme is always stable and effective at reducing the spectral radius for iterative transport solves, even for grids with high-aspect ratio cells. Numerical results are presented for different grid types: quadrilateral, hexagonal, and polygonal grids as well as grids with local mesh adaptivity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-J-133: Autosegmentation of Linac CBCT: Improved Accuracy Via Penalized Likelihood Reconstruction

Purpose: To improve the quality of kV X-ray cone beam CT (CBCT) for use in radiotherapy delivery assessment and re-planning by using penalized likelihood (PL) iterative reconstruction and auto-segmentation accuracy of the resulting CBCTs as an image quality metric. Methods: Present filtered backprojection (FBP) CBCT reconstructions can be improved upon by PL reconstruction with image formation models and appropriate regularization constraints. We use two constraints: 1) image smoothing via an edge preserving filter, and 2) a constraint minimizing the differences between the reconstruction and a registered prior image. Reconstructions of prostate therapy CBCTs were computed with constraint 1 alone and with both constraints. The prior images were planning CTs(pCT) deformable-registered to the FBP reconstructions. Anatomy segmentations were done using atlas-based auto-segmentation (Elekta ADMIRE). Results: We observed small but consistent improvements in the Dice similarity coefficients of PL reconstructions over the FBP results, and additional small improvements with the added prior image constraint. For a CBCT with anatomy very similar in appearance to the pCT, we observed these changes in the Dice metric: +2.9% (prostate), +8.6% (rectum), −1.9% (bladder). For a second CBCT with a very different rectum configuration, we observed +0.8% (prostate), +8.9% (rectum), −1.2% (bladder). For a third case with significant lateral truncation of the field of view, we observed: +0.8% (prostate), +8.9% (rectum), −1.2% (bladder). Adding the prior image constraint raised Dice measures by about 1%. Conclusion: Efficient and practical adaptive radiotherapy requires accurate deformable registration and accurate anatomy delineation. We show here small and consistent patterns of improved contour accuracy using PL iterative reconstruction compared with FBP reconstruction. However, the modest extent of these results and the pattern of differences across CBCT cases suggest that significant further development will be required to make CBCT useful to adaptive radiotherapy.

60 APPLIED LIFE SCIENCES↗

{sup 90}Y -PET imaging: Exploring limitations and accuracy under conditions of low counts and high random fraction

Purpose: {sup 90}Y -positron emission tomography (PET) imaging is becoming a recognized modality for postinfusion quantitative assessment following radioembolization therapy. However, the extremely low counts and high random fraction associated with {sup 90}Y -PET may significantly impair both qualitative and quantitative results. The aim of this work was to study image quality and noise level in relation to the quantification and bias performance of two types of Siemens PET scanners when imaging {sup 90}Y and to compare experimental results with clinical data from two types of commercially available {sup 90}Y microspheres. Methods: Data were acquired on both Siemens Biograph TruePoint [non-time-of-flight (TOF)] and Biograph microcomputed tomography (mCT) (TOF) PET/CT scanners. The study was conducted in three phases. The first aimed to assess quantification and bias for different reconstruction methods according to random fraction and number of true counts in the scan. The NEMA 1994 PET phantom was filled with water with one cylindrical insert left empty (air) and the other filled with a solution of {sup 90}Y . The phantom was scanned for 60 min in the PET/CT scanner every one or two days. The second phase used the NEMA 2001 PET phantom to derive noise and image quality metrics. The spheres and the background were filled with a {sup 90}Y solution in an 8:1 contrast ratio and four 30 min acquisitions were performed over a one week period. Finally, 32 patient data (8 treated with Therasphere{sup ®} and 24 with SIR-Spheres{sup ®}) were retrospectively reconstructed and activity in the whole field of view and the liver was compared to theoretical injected activity. Results: The contribution of both bremsstrahlung and LSO trues was found to be negligible, allowing data to be decay corrected to obtain correct quantification. In general, the recovered activity for all reconstruction methods was stable over the range studied, with a small bias appearing at extremely high random fraction and low counts for iterative algorithms. Point spread function (PSF) correction and TOF reconstruction in general reduce background variability and noise and increase recovered concentration. Results for patient data indicated a good correlation between the expected and PET reconstructed activities. A linear relationship between the expected and the measured activities in the organ of interest was observed for all reconstruction method used: a linearity coefficient of 0.89 ± 0.05 for the Biograph mCT and 0.81 ± 0.05 for the Biograph TruePoint. Conclusions: Due to the low counts and high random fraction, accurate image quantification of {sup 90}Y during selective internal radionuclide therapy is affected by random coincidence estimation, scatter correction, and any positivity constraint of the algorithm. Nevertheless, phantom and patient studies showed that the impact of number of true and random coincidences on quantitative results was found to be limited as long as ordinary Poisson ordered subsets expectation maximization reconstruction algorithms with random smoothing are used. Adding PSF correction and TOF information to the reconstruction greatly improves the image quality in terms of bias, variability, noise reduction, and detectability. On the patient studies, the total activity in the field of view is in general accurately measured by Biograph mCT and slightly overestimated by the Biograph TruePoint.

60 APPLIED LIFE SCIENCES↗

Fast multiscale contrast independent preconditioners for linear elastic topology optimization problems

The goal of this work is to present a fast and viable approach for the numerical solution of the high-contrast state problems arising in topology optimization. The optimization process is iterative, and the gradients are obtained by an adjoint analysis, which requires the numerical solution of large high-contrast linear elastic problems with features spanning several length scales. The size of the discretized problems forces the utilization of iterative linear solvers with solution time dependent on the quality of the preconditioner. The lack of clear separation between the scales, as well as the high-contrast, imposes severe challenges on the standard preconditioning techniques. Thus, here we propose new methods for the high-contrast elasticity equation with performance independent of the high-contrast and the multi-scale structure of the elasticity problem. The solvers are based on two-levels domain decomposition techniques with a carefully constructed coarse level to deal with the high-contrast and multi-scale nature of the problem. The construction utilizes spectral equivalence between scalar diffusion and each displacement block of the elasticity problems and, in contrast to previous solutions proposed in the literature, is able to select the appropriate dimension of the coarse space automatically. The new methods inherit the advantages of domain decomposition techniques, such as easy parallelization and scalability. Finally, the presented numerical experiments demonstrate the excellent performance of the proposed methods.

97 MATHEMATICS AND COMPUTING↗

EHR-BERT: A BERT-based model for effective anomaly detection in electronic health records

Objective: Physicians and clinicians rely on data contained in electronic health records (EHRs), as recorded by health information technology (HIT), to make informed decisions about their patients. The reliability of HIT systems in this regard is critical to patient safety. Consequently, better tools are needed to monitor the performance of HIT systems for potential hazards that could compromise the collected EHRs, which in turn could affect patient safety. In this paper, we propose a new framework for detecting anomalies in EHRs using sequence of clinical events. This new framework, EHR-Bidirectional Encoder Representations from Transformers (BERT), is motivated by the gaps in the existing deep-learning related methods, including high false negatives, sub-optimal accuracy, higher computational cost, and the risk of information loss. EHR-BERT is an innovative framework rooted in the BERT architecture, meticulously tailored to navigate the hurdles in the contemporary BERT method; thus, enhancing anomaly detection in EHRs for healthcare applications.Methods: The EHR-BERT framework was designed using the Sequential Masked Token Prediction (SMTP) method. This approach treats EHRs as natural language sentences and iteratively masks input tokens during both training and prediction stages. This method facilitates the learning of EHR sequence patterns in both directions for each event and identifies anomalies based on deviations from the normal execution models trained on EHR sequences.Results: Extensive experiments on large EHR datasets across various medical domains demonstrate that EHR-BERT markedly improves upon existing models. It significantly reduces the number of false positives and enhances the detection rate, thus bolstering the reliability of anomaly detection in electronic health records. This improvement is attributed to the model’s ability to minimize information loss and maximize data utilization effectively.Conclusion: EHR-BERT showcases immense potential in decreasing medical errors related to anomalous clinical events, positioning itself as an indispensable asset for enhancing patient safety and the overall standard of healthcare services. The framework effectively overcomes the drawbacks of earlier models, making it a promising solution for healthcare professionals to ensure the reliability and quality of health data.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

New method for fitting coefficients in standard model effective theory

We present an alternative method for carrying out a principal-component analysis of Wilson coefficients in standard model effective field theory (SMEFT). The method is based on singular-value decomposition (SVD). The SVD method provides information about the sensitivity of experimental observables to physics beyond the standard model that is not accessible in the Fisher-information method. In principle, the SVD method can also have computational advantages over diagonalization of the Fisher information matrix. We demonstrate the SVD method by applying it to the dimension-6 coefficients for the process of top-quark decay to a b quark and a W boson and use this example to illustrate some pitfalls in widely used fitting procedures. We also outline an iterative procedure for applying the SVD method to dimension-8 SMEFT coefficients.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Complex-valued acquisition of the diffraction imaging by incoherent quasimonochromatic light without a support constraint

A scheme for complex-valued acquisition of the diffraction imaging with quasimonochromatic incoherent light is theoretically proposed. The main idea is to project the real and the imaginary parts of a Fraunhofer diffraction field on intensity distributions, respectively, with the use of a {pi}/2 phase-changing plate. The whole procedure is iterative algorithm free and needs no a priori knowledge of an arbitrary object. A numerical experiment and a quantitative confirmation are also given. To our knowledge, it was the first physical proposal for the complex-valued acquisition of a diffraction imaging by two-dimensional coherent patterns with thermal illumination.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reconstruction of a time-averaged midposition CT scan for radiotherapy planning of lung cancer patients using deformable registration

Purpose: lower lobe lung tumors move with amplitudes of up to 2 cm due to respiration. To reduce respiration imaging artifacts in planning CT scans, 4D imaging techniques are used. Currently, we use a single (midventilation) frame of the 4D data set for clinical delineation of structures and radiotherapy planning. A single frame, however, often contains artifacts due to breathing irregularities, and is noisier than a conventional CT scan since the exposure per frame is lower. Moreover, the tumor may be displaced from the mean tumor position due to hysteresis. The aim of this work is to develop a framework for the acquisition of a good quality scan representing all scanned anatomy in the mean position by averaging transformed (deformed) CT frames, i.e., canceling out motion. A nonrigid registration method is necessary since motion varies over the lung. Methods and Materials: 4D and inspiration breath-hold (BH) CT scans were acquired for 13 patients. An iterative multiscale motion estimation technique was applied to the 4D CT scan, similar to optical flow but using image phase (gray-value transitions from bright to dark and vice versa) instead. From the (4D) deformation vector field (DVF) derived, the local mean position in the respiratory cycle was computed and the 4D DVF was modified to deform all structures of the original 4D CT scan to this mean position. A 3D midposition (MidP) CT scan was then obtained by (arithmetic or median) averaging of the deformed 4D CT scan. Image registration accuracy, tumor shape deviation with respect to the BH CT scan, and noise were determined to evaluate the image fidelity of the MidP CT scan and the performance of the technique. Results: Accuracy of the used deformable image registration method was comparable to established automated locally rigid registration and to manual landmark registration (average difference to both methods <0.5 mm for all directions) for the tumor region. From visual assessment, the registration was good for the clearly visible features (e.g., tumor and diaphragm). The shape of the tumor, with respect to that of the BH CT scan, was better represented by the MidP reconstructions than any of the 4D CT frames (including MidV; reduction of 'shape differences' was 66%). The MidP scans contained about one-third the noise of individual 4D CT scan frames. Conclusions: We implemented an accurate method to estimate the motion of structures in a 4D CT scan. Subsequently, a novel method to create a midposition CT scan (time-weighted average of the anatomy) for treatment planning with reduced noise and artifacts was introduced. Tumor shape and position in the MidP CT scan represents that of the BH CT scan better than MidV CT scan and, therefore, was found to be appropriate for treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sparsely corrupted stimulated scattering signals recovery by iterative reweighted continuous basis pursuit

In this paper, we consider the problem of extracting the desired signals from noisy measurements. This is a classical problem of signal recovery which is of paramount importance in inertial confinement fusion. To accomplish this task, we develop a tractable algorithm based on continuous basis pursuit and reweighted ℓ{sub 1}-minimization. By modeling the observed signals as superposition of scale time-shifted copies of theoretical waveform, structured noise, and unstructured noise on a finite time interval, a sparse optimization problem is obtained. We propose to solve this problem through an iterative procedure that alternates between convex optimization to estimate the amplitude, and local optimization to estimate the dictionary. The performance of the method was evaluated both numerically and experimentally. Numerically, we recovered theoretical signals embedded in increasing amounts of unstructured noise and compared the results with those obtained through popular denoising methods. We also applied the proposed method to a set of actual experimental data acquired from the Shenguang-II laser whose energy was below the detector noise-equivalent energy. Both simulation and experiments show that the proposed method improves the signal recovery performance and extends the dynamic detection range of detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗