A biofilm microreactor system for simultaneous electrochemical and nuclear magnetic resonance techniques

In order to fully understand electrochemically active biofilms and the limitations to their scale-up in industrial biofilm reactors, a complete picture of the microenvironments inside the biofilm is needed. Nuclear magnetic resonance (NMR) techniques are ideally suited for the study of biofilms and for probing their microenvironments because these techniques allow for non-invasive interrogation and in situ monitoring with high resolution. By combining NMR with simultaneous electrochemical techniques, it is possible to sustain and study live electrochemically active biofilms. Here, we introduce a novel biofilm microreactor system that allows for simultaneous electrochemical and NMR techniques (EC-NMR) at the microscale. Microreactors were designed with custom radiofrequency resonator coils, which allowed for NMR measurements of biofilms growing on polarized gold electrodes. For an example application of this system, we grew Geobacter sulfurreducens biofilms. NMR was used to investigate growth media flow velocities, which were compared to simulated laminar flow, and electron donor concentrations inside the biofilms. We use Monte Carlo error analysis to estimate standard deviations of the electron donor concentration measurements within the biofilm. The EC-NMR biofilm microreactor system can ultimately be used to correlate extracellular electron transfer rates with metabolic reactions and explore extracellular electron transfer mechanisms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Oxygen Isotope Microanalysis By Secondary Ion Mass Spectrometry Suggests Continuous 300-million-year History of Calcite Cementation and Dolomitization in the Devonian Bakken Formation

Calcite cementation and dolomitization are key diagenetic processes in many sedimentary systems. Unravelling detailed histories and timescales of cementation and replacement is, however, often compromised by the limited spatial resolution of many analytical techniques; in some cases multiple grains are co-analyzed so that diagenetic histories are blurred and reaction periods are difficult to establish. In this study we have used 10-micrometer-resolution, in situ secondary ion mass spectrometry to determine the oxygen isotope composition of 197 individual, 10–50-micrometer-size crystals of dolomite and calcite from six samples in a single core of Upper Devonian middle Bakken Member siltstones and sandstones, the major tight oil formation of the Williston basin, USA. This amount of data places important constraints on the range of temperatures and times that carbonate cementation and replacement occurred. Petrographic data show that microcrystalline calcite cement is an early phase, and combined with mineralogical data suggest that much of the dolomite replaces calcite. Over spatial scales of less than a centimeter, analyses of individual calcite crystals have a range of 5‰ for δ 18 O in the group of crystals, and for the group of individual dolomite crystals, 10‰. These sub-centimeter ranges are as great as those observed in previous studies of carbonate cements sampled over many meters and remind us that previous low-resolution studies may have inadvertently analyzed mixed phases. There is no relationship between dolomite texture and isotopic composition at this spatial scale; microscale backscattered electron imagery and scanning electron microscopy cathodoluminescence zoning is seen, but cannot be resolved with a 10-micrometer spot size. Assuming, since it is an early cement, that calcite precipitated from seawater (δ 18 O = –1.5‰), it formed at ca. 15–40°C, mainly at the lower temperatures. Present-day formation waters in Devonian rocks in this region have oxygen isotope compositions of 7–8‰ VSMOW. Using these values as a likely dolomitizing fluid, we suggest that dolomitization occurred continuously between 40 and 140°C over 150–200 million years, most likely in a fluid with a high Mg/Ca ratio resulting from gypsum formation in local evaporites. Finally, we suggest that this exceptionally low rate of dolomitization was controlled by the low rate of supply of Mg in a very sluggish flow regime; dolomitization is incomplete because of a limited supply of Mg.

58 GEOSCIENCES↗

Relations between light emission and electron density and temperature fluctuations in a helium plasma

The relations between three atomic lines, He I 667.8 nm (3{sup 1}D{yields} 2{sup 1}P), 706.5 nm (3{sup 3}S{yields} 2{sup 3}P), and 728.1 nm (3{sup 1}S{yields} 2{sup 1}P), and the underlying fluctuations in a helium plasma are investigated for the quantitative interpretation of optical observations in plasma fluctuation measurements. Frequency dependent fluctuation amplitude ratios and phase delays between the line emission fluctuation and the electron density and temperature fluctuations are calculated based on a quasi-static collisional-radiative model and a linear approximation technique. For frequencies up to the upper limit of practical interest (<1 MHz), the fluctuation amplitude ratios and phase delays are similar to those directly evaluated by the quasi-static model. It is found that the difference between the results from the linear approximation technique and from the quasi-static model is due to the absence of metastable fluctuations. Contributions of the 2{sup 1}S and 2{sup 3}S metastable fluctuations to the three helium line emission fluctuations are analyzed. The linearity between fluctuations in the line emission and in the electron density and temperature is valid for fluctuation levels higher than 10%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The fault-tree compiler

The Fault Tree Compiler Program is a new reliability tool used to predict the top event probability for a fault tree. Five different gate types are allowed in the fault tree: AND, OR, EXCLUSIVE OR, INVERT, and M OF N gates. The high level input language is easy to understand and use when describing the system tree. In addition, the use of the hierarchical fault tree capability can simplify the tree description and decrease program execution time. The current solution technique provides an answer precise (within the limits of double precision floating point arithmetic) to the five digits in the answer. The user may vary one failure rate or failure probability over a range of values and plot the results for sensitivity analyses. The solution technique is implemented in FORTRAN; the remaining program code is implemented in Pascal. The program is written to run on a Digital Corporation VAX with the VMS operation system.

Martensen, Anna L.↗

Full versus limited versus no steerability

The range of phenomena of the MST radar technique to divide the steerability versus nonsteerability problem into two broad with a third subset that lies between these two limits are studied. Processes that vary on a horizontal scale which are comparable to the area of the probing radar beam can best be fully steerable beams. The use of fixed beam systems would be a long term study of the mean wind field. Orographic effects due to mountain ridges and/or land-sea interfaces demand steerable beams, particularly if the effects are three dimensional in character. In view of their lack of moving parts fixed beam systems are more reliable. It is assumed that the reliability of a system is inversely proportioned to the number of moving parts. This is not a problem for fixed beam systems.

Balsley, B. B.↗

Microbial Cell Imaging

Atomic force microscopy (AFM) is finding increasing application in a variety of fields including microbiology. Until the emergence of AFM, techniques for ivnestigating processes in single microbes were limited. From a biologist's perspective, the fact that AFM can be used to generate high-resolution images in buffers or media is its most appealing feature as live-cell imaging can be pursued. Imaging living cells by AFM allows dynamic biological events to be studied, at the nanoscale, in real time. Few areas of biological research have as much to gain as microbiology from the application of AFM. Whereas the scale of microbes places them near the limit of resolution for light microscopy. AFM is well suited for the study of structures on the order of a micron or less. Although electron microscopy techniques have been the standard for high-resolution imaging of microbes, AFM is quickly gaining favor for several reasons. First, fixatives that impair biological activity are not required. Second, AFM is capable of detecting forces in the pN range, and precise control of the force applied to the cantilever can be maintained. This combination facilitates the evaluation of physical characteristics of microbes. Third, rather than yielding the composite, statistical average of cell populations, as is the case with many biochemical assays, the behavior of single cells can be monitored. Despite the potential of AFM in microbiology, there are several limitations that must be considered. For example, the time required to record an image allows for the study of gross events such as cell division or membrane degradation from an antibiotic but precludes the evaluation of biological reactions and events that happen in just fractions of a second. Additionally, the AFM is a topographical tool and is restricted to imaging surfaces. Therefore, it cannot be used to look inside cells as with opticla and transmission electron microscopes. other practical considerations are the limitation on the maximum scan size (roughly 100 x 100 {mu}m) and the restricted movement of the cantilever in the Z (or height) direction. In most commercial AFMs, the Z range is restricted to roughly 10 {mu}m such that the height of cells to be imaged must be seriously considered. Nevertheless, AFM can provide structural-functional information at nanometer resolution and do so in physiologically relevant environments. Further, instrumentation for scanning probe microscopy continues to advance. Systems for high-speed imaging are becoming available, and techniques for looking inside the cells are being demonstrated. The ability to combine AFM with other imaging modalities is likely to have an even greater impact on microbiological studies. AFM studies of intact microbial cells started to appear in the literature in the 1990s. For example, AFM studies of Saccharomyces cerevisiae examined buddings cars after cell division and detailed changes related to cell growth processes. Also, the first AFM studies of bacterial biofilms appeared. In the late 1990s, AFM studies of intact fungal spores described clear changes in spore surfaces upon germination, and studies of individual bacterial cells were also described. These early bacterial imaging studies examined changes in bacterial morphology due to antimicrobial peptides exposure and bacterial adhesion properties. The majority of these early studies were carried out on dried samples and took advantage of the resolving power of AFM. The lack of cell mounting procedures presented an impediment for cell imaging studies. Subsequently, several approaches to mounting microbial cells have been developed, and these techniques are described later. Also highlighted are general considerations for microbial imaging and a description of some of the various applications of AFM to microbiology.

60 APPLIED LIFE SCIENCES↗

Metals Analysis of Biodiesel Blends

The goal of this study was to compare metals analysis methods for biodiesel blends. Thirty-five B20 samples were collected from public stations and private fleets throughout the United States. All samples were analyzed for blend content and critical properties under the ASTM D7467 specification. Although not part of the specification, metals content, specifically Na, K, Ca, Mg, and P, is becoming an increasingly larger concern for industry. This study compared the metals content of the B20 samples using inductively coupled plasma atomic emission spectroscopy (ICP-AES), inductively coupled plasma mass spectrometry (ICP-MS), and microwave plasma atomic emission spectroscopy (MP-AES) methods. All three techniques showed improvements over the current detection limits of 1 ppm for Na, K, Ca, and Mg, and 5 ppm for P. Some differences were found between methods, but agreement was generally acceptable at the very low levels present in these samples. The MP-AES technique showed good promise for future development for this type of analysis.

33 ADVANCED PROPULSION SYSTEMS↗

Whitecap coverage from aerial photography

A program for determining the feasibility of deriving sea surface wind speeds by remotely sensing ocean surface radiances in the nonglitter regions is discussed. With a knowledge of the duration and geographical extent of the wind field, information about the conventional sea state may be derived. The use of optical techniques for determining sea state has obvious limitations. For example, such means can be used only in daylight and only when a clear path of sight is available between the sensor and the surface. However, sensors and vehicles capable of providing the data needed for such techniques are planned for the near future; therefore, a secondary or backup capability can be provided with little added effort. The information currently being sought regarding white water coverage is also of direct interest to those working with passive microwave systems, the study of energy transfer between winds and ocean currents, the aerial estimation of wind speeds, and many others.

Austin, R. W.↗

The Fault Tree Compiler (FTC): Program and mathematics

The Fault Tree Compiler Program is a new reliability tool used to predict the top-event probability for a fault tree. Five different gate types are allowed in the fault tree: AND, OR, EXCLUSIVE OR, INVERT, AND m OF n gates. The high-level input language is easy to understand and use when describing the system tree. In addition, the use of the hierarchical fault tree capability can simplify the tree description and decrease program execution time. The current solution technique provides an answer precisely (within the limits of double precision floating point arithmetic) within a user specified number of digits accuracy. The user may vary one failure rate or failure probability over a range of values and plot the results for sensitivity analyses. The solution technique is implemented in FORTRAN; the remaining program code is implemented in Pascal. The program is written to run on a Digital Equipment Corporation (DEC) VAX computer with the VMS operation system.

Butler, Ricky W.↗

Quantifying Properties for a Mechanistic, Predictive Understanding of Aqueous Impact on Aging of Medium and Low Voltage AC and DC Cabling in Nuclear Power Plants

To address the gap in knowledge in understanding degradation in relevant service conditions, this project aimed to develop a mechanistic, predictive model of medium and low voltage cable failure based on the primary environmental degradation parameters of aqueous immersion time, temperature, and the oxidation extent. To do so, we took a two-fold approach toward evaluating degradation as related to the aqueous condition. First, we evaluated the chemical, mechanical, and electrical properties of polymers that comprise the cabling insulation under varied aqueous conditions at different temperatures. Secondly, we evaluated the performance of insulation materials under similar accelerated aging conditions in addition to the dielectric breakdown of the cabling under submersion conditions. Thermal oxidation and immersion of LDPE thin films were done using a Parr vessel and the extent of oxidation was monitored using the carbonyl index from ATR-FTIR spectrum, a ratio quantifying the carbonyl functionality produced on the LDPE film surface. Increasing the temperature, oxidation time, and oxygen pressure increased the water-vapor permeability and the carbonyl content. Thermogravimetric analysis of the films confirmed that there is indeed an initial weight loss of the smaller molecular weight molecules and volatiles. At higher temperatures, there is a secondary mass loss. Up to 70°C, the mass loss curves were similar until 80°C, when the aged films decreased at a much greater rate with respect to increasing temperature. This was seen in the 10, 50, 90% weight loss temperatures. The mechanical properties of sheet PP and HDPE as well as injection molded LDPE, HDPE, HDPP dog bones were plotted with respect to the time spent in the Parr vessel during thermal oxidation. For the sheet PP and HDPE, the UTS and the modulus of elasticity decreased while the elongation increased. The injection-molded LDPE, HDPE, and HDPP dog bones experienced a similar trend where the changes in the properties were within experimental uncertainty. This analysis of LDPE in dry and immersive oxygen-rich environments is an important baseline for future experiments looking at other degradation mechanisms. A predictive aging model for low-density polyethylene insulative cable housings was developed. This model revealed a combination of physical and chemical processes which lead to an increase in permeability and a decrease in strength of the insulator. In creating this predictive model, a gap of knowledge in the literature was revealed in two areas: understanding how the crystallinity of a polymer changes with time and visualizing the predicted pores formed through the insulator which leads to failure. Developing and using an adapted ATR-FTIR method, crystallinity was monitored and compared to bulk crystallinity found via DSC. Inhomogeneity in crystallinity changes were observed but the FTIR method but was found to be less reliable. Pore visualization was found utilizing electrical impedance spectroscopy saturated aged polyethylene films with synthesized citrate-capped gold nanoparticles, and chloroauric acid precursor. results indicate a decreasing impedance of the polyethylene films caused by the transport of ions through the film. SEM imaging was then performed for elemental analysis of the films and counter electrodes for the presence of ions. Chloride and gold ions were detected; however, no nanoparticles were found. This gives an estimated pore size of at least 0.3 nm through the aged film. Cyclic submergence of polyethylene and polypropylene in aqueous solutions of copper sulfate and Harrison’s solution were examined. It was discovered that aging in these mixed conditions and at 90°C did cause a small, yet significant increase to tensile strength for both unaged polyethylene and polypropylene. The PE and PP in cycled and submerged conditions did not have tensile strengths significantly different from dry-aged after 16 weeks. For both solutions, it was determined that capacitance increases with both water tree depth and cable temperature and is relatively independent of changing water tree AR. As for resistance, there is no apparent change between depth percentages of 10 and 80 for both solutions. This is because the water tree has not yet entered the conductor and thus there is no shorting current flowing through the tree yet. Between 80 and 100% water tree depth, it is observed that for both solutions there is a rapid decrease in resistance because the tree is now impacting the conductor shield and allowing shorting current to flow through it. The relationship between resistance and temperature was found to be inversed. As temperature increases, resistance decreases for both water tree solutions with distilled water having the most apparent difference across the range of temperatures simulated. With regards to water tree AR, resistance was found to be relatively independent at depth percentages of 10, 50, and 70, but there was some relationship at 100% depth for both solutions. At this depth, as water tree AR increased, resistance was found to also increase. Through the examination of voltage and electric field distribution plots, it was confirmed for EPR cables that increasing water tree depth leads to increasing distortion. The increase in shorting current at 100% depth for aqueous copper sulfate compared to distilled water was also visualized. Lastly, the relationship between shorting current and temperature for narrow water trees was visualized and validated using the distribution plots. This study has led to a better understanding of the effect of cable temperature, water tree solution, and geometry of the tree region on cable degradation. Furthermore, this study has documented simulation results of water tree degradation in EPR MV cables, which had been previously lacking in information. Future work in this area will add frequency into the mix and examine what effect it has on the rate of cable degradation as a result of water treeing. To compliment the work being carried by UMD on different polymer chemistries, harvested medium voltage (MV) cables were selected for accelerated aging study at ORNL. These medium voltage cables are representative of the vintages and materials that are currently in use at existing nuclear power plants (NPPs). These cables were immersed in water at 90°C and energized for a period of two years at elevated voltage. Partial discharge was measured during this period of time to track potential degradation. Unfortunately, due to the absence of failure, the extent of integration between the UMD techniques and the harvested MV insulation was limited. However, based on the findings and from the UMD research in the previous sections on polyethylene and polypropylene, follow-on characterization for harvested MV cable insulation should focus on sample preparation to take advantage of the UMD techniques to better understand mechanistic degradation in MV cable insulations. This would include: 1.) Utilization of solutions and impedance measurement insulation to track permeability in harvested and accelerated aging insulation samples, 2.) Adaptation of gold nanoparticle synthesis for electrical impedance spectroscopy with supporting SEM characterization to study pore formation in harvested and accelerated aged insulation samples, & 3.) ATR-FTIR crystallinity with multiple temperature dependent harvested MV cable insulation under different air and submerged accelerated aging. In addition, low voltage dielectric spectroscopy and high voltage dissipation factor, tan δ, could be implemented as a condition monitoring tool for harvested MV cable insulation in submerged environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Personnel Qualification and Certification Program in Pressure Decay Leak Testing on the RT-100 Type (B) Cask - 17229

The requirements for qualifications and certification of leak test personnel on Type (B) shipping casks have been more clearly defined with the recent release of ANSI N14.5-2014, Leak Tests on Radioactive Packages for Shipment. The latest version creates a standardized approach for qualifying and certifying personnel to conduct pre-shipment leakage tests on Type (B) packages. The U.S Nuclear Regulatory Commission (NRC) is currently updating the Regulatory Guide R.G 7.4, Leakage Tests on Packages for shipment of Radioactive Material, to endorse ANSI N14.5-2014. According to ANSI N14.5-2014, leakage testing shall be performed in accordance with written procedures by qualified and certified personnel in accordance with the requirements of ASNT SNT-TC-1A-2006, Recommended Practice for Personnel Qualification and Certification in Nondestructive Testing. This is a significant modification to the old standard, ANSI N14.5-1997, which simply states that pressure leak testing shall be conducted by trained and certified personnel without reference to any specific certification standards or regulations. SNT-TC-1A published by the American Society for Nondestructive Testing (ASNT) has several advantages to employers; namely, it allows for a Limited NDT Level II certification program. Limited certifications are especially valuable for personnel who possess limited experience and wish to become a certified Limited NDT Level II in a specific technique on a specific cask using a specific procedure and equipment. Robatel Technologies recently developed a comprehensive qualification and training program based on the recommendations of SNT-TC-1A for Exelon Corporation to certify their employees to a Limited NDT Level II in Pressure Decay Leak Testing on the RT-100 Cask. The project scope included the development of a training and qualification program (Written practice), writing a pressure decay leak test procedure, the design of a pressure decay leak test manifold, and the delivery of classroom training. The written practice outlines the requirements to ensure that personnel participating in the program have the necessary qualification, experience, and training to become certified in the leak test method. The program will give Exelon the liberty to conduct their own leak testing on the RT- 100 without the need to rely on outside resources for leak testing. When fully implemented, the program is expected to improve productivity and eliminate schedule delays, along with substantial economic benefits. Following the appropriate standards and industry best practices, the project was successfully completed and scheduled to be fully implemented by Exelon's Nuclear Stations by the end of 2016. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Quantifying the passive gamma signal from spent nuclear fuel in support of determining the plutonium content in spent nuclear fuel with nondestructive assay

The objective of safeguarding nuclear material is to deter diversions of significant quantities of nuclear materials by timely monitoring and detection. There are a variety of motivations for quantifying plutonium in spent fuel (SF), by means of nondestructive assay (NDA), in order to meet this goal. These motivations include the following: strengthening the capabilities of the International Atomic Energy Agencies ability to safeguard nuclear facilities, shipper/receiver difference, input accountability at reprocessing facilities and burnup credit at repositories. Many NDA techniques exist for measuring signatures from SF; however, no single NDA technique can, in isolation, quantify elemental plutonium in SF. A study has been undertaken to determine the best integrated combination of 13 NDA techniques for characterizing Pu mass in spent fuel. This paper focuses on the development of a passive gamma measurement system in support the spent fuel assay system. Gamma ray detection for fresh nuclear fuel focuses on gamma ray emissions that directly coincide with the actinides of interest to the assay. For example, the 186-keV gamma ray is generally used for {sup 235}U assay and the 384-keV complex is generally used for assaying plutonium. In spent nuclear fuel, these signatures cannot be detected as the Compton continuum created from the fission products dominates the signal in this energy range. For SF, the measured gamma signatures from key fission products ({sup 134}Cs, {sup 137}Cs, {sup 154}Eu) are used to ascertain burnup, cooling time, and fissile content information. In this paper the Monte Carlo modeling set-up for a passive gamma spent fuel assay system will be described. The set-up of the system includes a germanium detector and an ion chamber and will be used to gain passive gamma information that will be integrated into a system for determining Pu in SF. The passive gamma signal will be determined from a library of {approx} 100 assemblies that have been created to examine the capability of all 13 NDA techniques. Presented in this paper is a description of the passive gamma monitoring instrument, explanation of the work completed thus far involving the source set up methodology and the design optimization process, details of key fission product ratios of interest, limitations and key strengths of the measurement technique, and considerations for integrating this technique with other NDA techniques in order to develop a complete spent fuel assay strategy.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

DOLCE: A Model-Based Probabilistic Diffusion Framework for Limited-Angle CT Reconstruction

Limited-Angle Computed Tomography (LACT) is a non-destructive evaluation technique used in a variety of applications ranging from security to medicine. The limited angle coverage in LACT is often a dominant source of severe artifacts in the reconstructed images, making it a challenging inverse problem. We present DOLCE, a new deep model-based framework for LACT that uses a conditional diffusion model as an image prior. Diffusion models are a recent class of deep generative models that are relatively easy to train due to their implementation as image denoisers. DOLCE can form high-quality images from severely under-sampled data by integrating data-consistency updates with the sampling updates of a diffusion model, which is conditioned on the transformed limited-angle data. We show through extensive experimentation on several challenging real LACT datasets that, the same pre-trained DOLCE model achieves the SOTA performance on drastically different types of images. Additionally, we show that, unlike standard LACT reconstruction methods, DOLCE naturally enables the quantification of the reconstruction uncertainty by generating multiple samples consistent with the measured data.

Kim, Hyojin↗

On the feasibility of benefit-cost analysis applied to remote sensing projects

The following step-wise procedure for making a benefit-cost analysis of using remote sensing techniques could be used either in the limited context of California water resources, or a context as broad as the making of integrated resource surveys of the entire earth resource complex on a statewide, regional, national, or global basis. (1) Survey all data collection efforts which can be accomplished by remote sensing techniques. (2) Carefully inspect the State of California budget and the Budget of the United States Government to find annual cost of data collection efforts. (3) Decide the extent to which remote sensing can obviate each of the collection efforts. (4) Sum the annual costs of all data collection which can be equivalently accomplished through remote sensing. (5) Decide what additional data could and would be collected through remote sensing. (6) Estimate the value of this information. It is not harmful to do a benefit-cost analysis so long as its severe limitations are recalled and it is supplemented with socio-economic impact studies.

Merewitz, L.↗

Hybrid Chemo-Mechanical Plastics Recycling: Solvent-free, High-speed Reactive Extrusion of Low-Density Polyethylene

Low-Density Polyethylene (LDPE) is ubiquitous in the packaging industry due to its flexibility, toughness, and low cost. However, it is typically contaminated with other materials, seriously limiting options for mechanical recycling. Interest in chemical recycling techniques such as pyrolysis and hydrothermal liquefaction is growing, but most of these processes face technoeconomic challenges that have limited commercial deployment. We present a hybrid chemo-mechanical approach using reactive twin-screw extrusion (TSE) for tailoring the molecular weight and chain structure of reclaimed LDPE. Two types of zeolite catalysts at several loading levels were evaluated over a range of processing conditions. Structural, thermal, and rheological properties of the extruded samples were investigated and compared to virgin LDPE and LDPE extruded without the catalyst. A nuclear magnetic resonance spectroscopic technique was used to investigate changes in the structure of the polymer. LDPE extruded with microporous y-zeolite showed lower degradation temperature and increased short chain branching. Mesoporous MCM-41 also induced increased branching but had no effect on degradation temperature. The theoretical mechanical energy input for the chemical modification was calculated using process modeling. The demonstrated hybrid reactive extrusion process provides a potential low-cost, simple approach for repurposing LDPE-based flexible packaging as coatings and adhesives.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Micropuncture of Bowman's Space in Mice Facilitated by 2 Photon Microscopy

Renal micropuncture and renal 2-photon imaging are seminal techniques in renal physiology. However, micropuncture is limited by dependence on conventional microscopy to surface nephron features, and 2-photon studies are limited in that interventions can only be assessed at the organ, rather than the nephron level. In particular, micropuncture studies of the glomeruli of mice have been challenged by the paucity of surface glomeruli in mice. To address this limitation in order to pursue studies of aspirate from Bowman's space in mouse physiologic models, we developed 2-photon glomerular micropuncture. We present a novel surgical preparation that allows lateral access to the kidney while preserving the required vertical imaging column for 2-photon microscopy. Administration of high molecular weight fluorescein isothiocyanate (FITC)- dextran is used to render the renal vasculature and therefore glomeruli visible for 2-photon imaging. A quantum dot-coated pipette is then introduced under stereotactic guidance to a glomerulus selected from the several to many which may be visualized within the imaging window. In this protocol, we provide details of the preparation, materials, and methods necessary to carry out the procedure. This technique facilitates previously-impossible physiologic study of the kidney, including recovery of filtrate from Bowman's space and all segments of the nephron within the imaging depth limit, about 100 µm below the renal capsule. Pressure, charge and flow may all be measured using the introduced pipette. Here, we provide representative data from liquid chromatography/mass spectrometry performed on aspirate from Bowman's space. We expect this technique to have wide applicability in renal physiologic investigation.

Matsushita, Katsuyuki↗

DIY 3D Microparticle Generation from Next Generation Optofluidic Fabrication

Abstract Complex‐shaped microparticles can enhance applications in drug delivery, tissue engineering, and structural materials, although techniques to fabricate these particles remain limited. A microfluidics‐based process called optofluidic fabrication that utilizes inertial flows and ultraviolet polymerization has shown great potential for creating highly 3D‐shaped particles in a high‐throughput manner, but the particle dimensions are mainly at the millimeter scale. Here, a next generation optofluidic fabrication process is presented that utilizes on‐the‐fly fabricated multiscale fluidic channels producing customized sub‐100 µm 3D‐shaped microparticles. This flexible design scheme offers a user‐friendly platform for rapid prototyping of new 3D particle shapes, providing greater potential for creating impactful engineered microparticles.

3D microparticles↗

Rewritable Surface‐Grafted Polymer Brushes with Dynamic Covalent Linkages

Abstract Surface grafting of polymer brushes drastically modifies surface properties, including wettability, compatibility, responsiveness, etc. A broad variety of functionalities can be introduced to the surface via different types of polymers. Bringing together properties of two or more types of polymer brushes to one surface opens up even more possibilities in brush‐modified materials. However, while it is generally feasible to introduce several chemical compositions along the brushes via copolymerization, it is challenging to vary the types of polymer brushes along a surface. Although previous studies have demonstrated binary brushes via orthogonal polymerization techniques or partial deactivation/regrafting, they commonly limit the number of polymer types to two. Here, we propose a strategy to introduce dynamic covalent diketoenamine linkages at the root of polymer brushes. The grafting density could be precisely tuned during surface functionalization. The surface‐anchored polymer brushes were cleaved by the addition of small molecule amines. New polymer brushes can be regrafted from the surface following refunctionalization of exposed sites. The maneuverability allows tuning of the types and densities of the polymer brushes, pointing the way to the preparation of a new generation of well‐defined brush‐modified materials with mixed grafts, with potential applications in the design of smart materials and surfaces.