Search NASA⌕ Search

SEARCH · Search NASA

Results for “microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Microscopic Calculation of 240Pu Scission with a Finite-Range Effective Force

Hartree-Fock-Bogoliubov calculations of hot fission in {sup 240}Pu have been performed with a newly-implemented code that uses the D1S finite-range effective interaction. The hot-scission line is identified in the quadrupole-octupole-moment coordinate space. Fission-fragment shapes are extracted from the calculations. A benchmark calculation for {sup 226}Th is obtained and compared to results in the literature. In addition, technical aspects of the use of HFB calculations for fission studies are examined in detail. In particular, the identification of scission configurations, the sensitivity of near-scission calculations to the choice of collective coordinates in the HFB iterations, and the formalism for the adjustment of collective-variable constraints are discussed. The power of the constraint-adjustment algorithm is illustrated with calculations near the critical scission configurations with up to seven simultaneous constraints.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Magnetic-force-microscope Study of Interlayer _Kinks_ in Individual Vortices in Underdoped Cuprate YBa2Cu3O6 x Superconductor

We use magnetic force microscopy to both image and manipulate individual vortex lines threading single crystalline YBa{sub 2}Cu{sub 3}O{sub 6.4}, a layered superconductor. We find that when we pull the top of a pinned vortex, it may not tilt smoothly. Sometimes, we observe a vortex to break into discrete segments that can be described as short stacks of pancake vortices, similar to the 'kinked' structure proposed by Benkraouda and Clem. Quantitative analysis gives an estimate of the pinning force and the coupling between the stacks. Our measurements highlight the discrete nature of stacks of pancake vortices in layered superconductors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

RIPL - Reference Input Parameter Library for Calculation of Nuclear Reactions and Nuclear Data Evaluations

We describe the physics and data included in the Reference Input Parameter Library, which is devoted to input parameters needed in calculations of nuclear reactions and nuclear data evaluations. Advanced modelling codes require substantial numerical input, therefore the International Atomic Energy Agency (IAEA) has worked extensively since 1993 on a library of validated nuclear-model input parameters, referred to as the Reference Input Parameter Library (RIPL). A final RIPL coordinated research project (RIPL-3) was brought to a successful conclusion in December 2008, after 15 years of challenging work carried out through three consecutive IAEA projects. The RIPL-3 library was released in January 2009, and is available on the Web through (http://www-nds.iaea.org/RIPL-3/). This work and the resulting database are extremely important to theoreticians involved in the development and use of nuclear reaction modelling (ALICE, EMPIRE, GNASH, UNF, TALYS) both for theoretical research and nuclear data evaluations. The numerical data and computer codes included in RIPL-3 are arranged in seven segments: MASSES contains ground-state properties of nuclei for about 9000 nuclei, including three theoretical predictions of masses and the evaluated experimental masses of Audi et al. (2003). DISCRETE LEVELS contains 117 datasets (one for each element) with all known level schemes, electromagnetic and {gamma}-ray decay probabilities available from ENSDF in October 2007. NEUTRON RESONANCES contains average resonance parameters prepared on the basis of the evaluations performed by Ignatyuk and Mughabghab. OPTICAL MODEL contains 495 sets of phenomenological optical model parameters defined in a wide energy range. When there are insufficient experimental data, the evaluator has to resort to either global parameterizations or microscopic approaches. Radial density distributions to be used as input for microscopic calculations are stored in the MASSES segment. LEVEL DENSITIES contains phenomenological parameterizations based on the modified Fermi gas and superfluid models and microscopic calculations which are based on a realistic microscopic single-particle level scheme. Partial level densities formulae are also recommended. All tabulated total level densities are consistent with both the recommended average neutron resonance parameters and discrete levels. GAMMA contains parameters that quantify giant resonances, experimental gamma-ray strength functions and methods for calculating gamma emission in statistical model codes. The experimental GDR parameters are represented by Lorentzian fits to the photo-absorption cross sections for 102 nuclides ranging from {sup 51}V to {sup 239}Pu. FISSION includes global prescriptions for fission barriers and nuclear level densities at fission saddle points based on microscopic HFB calculations constrained by experimental fission cross sections.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monte Carlo Simulation of Electron Thermalization in Scintillator Materials: Implications for Scintillator Nonproportionality

The lack of reliable quantitative estimates of the length and time scales associated with hot electron thermalization after a gamma-ray induced energy cascade obscures the interplay of various microscopic processes controlling scintillator performance and hampers the search for improved detector materials. We apply a detailed microscopic kinetic Monte Carlo model of the creation and subsequent thermalization of hot electrons produced by gamma irradiation of six important scintillating crystals to determine the spatial extent of the cloud of excitations produced by gamma rays and the time required for the cloud to thermalize with the host lattice. The main ingredients of the model are ensembles of microscopic track structures produced upon gamma excitation (including the energy distribution of the excited carriers), numerical estimates of electron-phonon scattering rates, and a calculated particle dispersion to relate the speed and energy of excited carriers. All these ingredients are based on first-principles density functional theory calculations of the electronic and phonon band structures of the materials. Details of the Monte Carlo model are presented along with results for thermalization time and distance distributions. These results are discussed in light of previous work. It is found that among the studied materials, calculated thermalization distances are positively correlated with measured nonproportionality. In the important class of halide scintillators, the particle dispersion is found to be more influential than the largest phonon energy in determining the thermalization distance.

Phonons, radiation detection, scintillators, thema↗

Visions of Atomic Scale Tomography

A microscope, by definition, provides structural and analytical information about objects that are too small to see with the unaided eye. From the very first microscope, efforts to improve its capabilities and push them to ever-finer length scales have been pursued. In this context, it would seem that the concept of an ultimate microscope would have received much attention by now; but has it really ever been defined? Human knowledge extends to structures on a scale much finer than atoms, so it might seem that a proton-scale microscope or a quark-scale microscope would be the ultimate. However, we argue that an atomic-scale microscope is the ultimate for the following reason: the smallest building block for either synthetic structures or natural structures is the atom. Indeed, humans and nature both engineer structures with atoms, not quarks. So far as we know, all building blocks (atoms) of a given type are identical; it is the assembly of the building blocks that makes a useful structure. Thus, would a microscope that determines the position and identity of every atom in a structure with high precision and for large volumes be the ultimate microscope? We argue, yes. In this article, we consider how it could be built, and we ponder the answer to the equally important follow-on questions: who would care if it is built, and what could be achieved with it?

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A numerical-homogenization based phase-field fracture modeling of linear elastic heterogeneous porous media

Most porous media, such as geomaterials and biomaterials are highly heterogeneous in nature, and they contain large variations of microscopic pore structures, such as pore sizes, pore distribution, and pore shapes. The oscillation of microscopic structures is a substantial challenge in theoretical characterization and is usually ignored in continuous modeling. However, mechanical behavior of porous media such as deformation and failure, are essentially impacted by the microscopic heterogeneity which needs to be considered in modeling a porous media. Here, this research proposes a numerical modeling framework with a capability to investigate the effect of microscopic heterogeneity on the macroscopic fracture behavior in porous media by using a numerical homogenization technique, combined with the phase-field fracture modeling method. This numerical modeling strategy computes a homogenized elasticity tensor based on microscopic heterogeneous pore structures heterogenous porous domain by solving boundary value problems at microscopic domain. The strain energy and subsequent propagation of macroscopic fractures will be updated using homogenized stiffness information. Using this numerical scheme, the microscopic pore structure’s impact on the fracture behavior through the homogenized elastic tensor will be taken into account. This multiscale technique is benchmarked against classical problems. Finally, the results highlight the importance of the underlying pore structure and reveal that both fracture strength and propagation path can be influenced by the microscopic heterogeneity.

36 MATERIALS SCIENCE↗

In vivo virtual intraoperative surgical photoacoustic microscopy

We developed a virtual intraoperative surgical photoacoustic microscopy system by combining with a commercial surgical microscope and photoacoustic microscope (PAM). By sharing the common optical path in the microscope and PAM system, we could acquire the PAM and microscope images simultaneously. Moreover, by employing a beam projector to back-project 2D PAM images onto the microscope view plane as augmented reality, the conventional microscopic and 2D cross-sectional PAM images are concurrently mapped on the plane via an ocular lens of the microscope in real-time. Further, we guided needle insertion into phantom ex vivo and mice skins in vivo.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging penetrating radiation through ion photon emission microscopy.

The ion photon emission microscope (IPEM), a new radiation effects microscope for the imaging of single event effects from penetrating radiation, is being developed at Sandia National Laboratories and implemented on the 88' cyclotron at Lawrence Berkeley National Laboratories. The microscope is designed to permit the direct correlation between the locations of high-energy heavy-ion strikes and single event effects in microelectronic devices. The development of this microscope has required the production of a robust optical system that is compatible with the ion beam lines, design and assembly of a fast single photon sensitive measurement system to provide the necessary coincidence, and the development and testing of many scintillating films. A wide range of scintillating material for application to the ion photon emission microscope has been tested with few meeting the stringent radiation hardness, intensity, and photon lifetime requirements. The initial results of these luminescence studies and the current operation of the ion photon emission microscope will be presented. Finally, the planned development for future microscopes and ion luminescence testing chambers will be discussed.

43 PARTICLE ACCELERATORS↗

Understanding diseases at a molecular level

A group of scientists at Los Alamos National Laboratory in 2008 successfully pioneered a microscope able to track protein-sized, hard to see particles in three dimensions. The 3D Tracking Microscope, designed and developed by James H. Werner, Guillaume A. Lessard, Nathan Wells and Peter M. Goodwin of LANL's Center for Integrated Nanotechnologies, won a 2008 R&D 100 award. The team's invention is a unique confocal 3D tracking microscope capable of following the motion of nanometer-sized objects, such as individual molecules, quantum dots, organic fluorophores and single green fluorescent proteins as they zoom through three-dimensional space at rates faster than many intracellular transport processes. The 3D tracking microscope can follow the transport of nanometer-sized particles at micrometer per second rates. This enables researchers to follow individual protein, ribonucleic acid (RNA), or deoxyribonucleic acid (DNA) motion throughout the full three-dimensional volume of a cell to discover the path a particular biomolecule takes, the method it employs to get there and the specific proteins it may be interacting with along the way. In addition to applications in molecular spectroscopy and materials research, the 3D tracking microscope is a powerful tool primarily in the fields of cellular biology and biomedical research, Werner said. 'The 3D tracking microscope will advance our understanding of the molecular basis and kinetics of many diseases, such as cancer, diabetes, or muscular dystrophy,' he said. 'We anticipate the microscope will become a valuable weapon in the arsenal of biomedical researchers who are fighting to find cures for cancer, heart disease and other protein or DNA-based diseases.'

47 OTHER INSTRUMENTATION↗

Relationship between Conductivity, Ion Diffusion, and Transference Number in Perfluoropolyether Electrolytes

Connecting continuum-scale ion transport properties such as conductivity and cation transference number to microscopic transport properties such as ion dissociation and ion self-diffusivities is an unresolved challenge in characterizing polymer electrolytes. Better understanding of the relationship between microscopic and continuum scale transport properties would enable the rational design of improved electrolytes for applications such as lithium batteries. Here, we present measurements of continuum and microscopic ion transport properties of nonflammable liquid electrolytes consisting of binary mixtures of lithium bis(trifluoromethanesulfonyl)imide (LiTFSI) and perfluoropolyethers (PFPE) with different end groups: diol, dimethyl carbonate, ethoxy-diol, and ethoxy-dimethyl carbonate. The continuum properties, conductivity and cation transference number, were measured by ac impedance spectroscopy and potentiostatic polarization, respectively. The ion self-diffusivities were measured by pulsed field gradient nuclear magnetic resonance spectroscopy (PFG-NMR), and a microscopic cation transference number was calculated from these measurements. The measured ion self-diffusivities did not reflect the measured conductivities; in some cases, samples with high diffusivities exhibited low conductivity. We introduce a nondimensional parameter, β, that combines microscopic diffusivities and conductivity. We show that β is a sensitive function of end-group chemistry. In the ethoxylated electrolytes, β is close to unity, the value expected for electrolytes that obey the Nernst-Einstein equation. In these cases, the microscopic and continuum transference numbers are in reasonable agreement. PFPE electrolytes devoid of ethoxy groups exhibit values of β that are significantly lower than unity. In these cases, there is significant deviation between microscopic and continuum transference numbers. We propose that this may be due to electrostatic coupling of the cation and anion or contributions to the NMR signal from neutral ion pairs.

25 ENERGY STORAGE↗

'Micromanaging de Sitter holography'

We develop tools to engineer de Sitter vacua with semi-holographic duals, using elliptic fibrations and orientifolds to uplift Freund-Rubin compactifications with CFT duals. The dual brane construction is compact and constitutes a microscopic realization of the dS/dS correspondence, realizing d-dimensional de Sitter space as a warped compactification down to (d-1)-dimensional de Sitter gravity coupled to a pair of large-N matter sectors. This provides a parametric microscopic interpretation of the Gibbons-Hawking entropy. We illustrate these ideas with an explicit class of examples in three dimensions, and describe ongoing work on four-dimensional constructions. The Gibbons-Hawking entropy of the de Sitter horizon [1] invites a microscopic interpretation and a holographic formulation of inflating spacetimes. Much progress was made in the analogous problem in black hole physics using special black holes in string theory whose microstates could be reliably counted, such as those analyzed in [2,3]; this led to the AdS/CFT correspondence [4]. In contrast, a microscopic understanding of the entropy of de Sitter space is more difficult for several reasons including its potential dynamical connections to other backgrounds (metastability), the absence of a non-fluctuating timelike boundary, and the absence of supersymmetry. In this paper, we develop a class of de Sitter constructions in string theory, built up from AdS/CFT dual pairs along the lines of [5], which are simple enough to provide a microscopic accounting of the parametric scaling of the Gibbons-Hawking entropy. These models realize microscopically a semi-holographic description of metastable de Sitter space which had been derived macroscopically in [6]. It would also be interesting to connect this to other approaches to de Sitter holography such as [7, 8] and to other manifestations of the de Sitter entropy such as [9]. The construction is somewhat analogous to neutral black branes analyzed in [11]. We will begin in section 2 by explaining the salient features of the holographic duality and of the de Sitter construction which realizes it microscopically. In section 3 we will lay out our methods in more detail, applying them to worked examples of dS{sub 3} in section 4. Finally, section 5 discusses further directions and ongoing work, including dS{sub 4} constructions in progress.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Aberration-Coreected Electron Microscopy at Brookhaven National Laboratory

The last decade witnessed the rapid development and implementation of aberration correction in electron optics, realizing a more-than-70-year-old dream of aberration-free electron microscopy with a spatial resolution below one angstrom [1-9]. With sophisticated aberration correctors, modern electron microscopes now can reveal local structural information unavailable with neutrons and x-rays, such as the local arrangement of atoms, order/disorder, electronic inhomogeneity, bonding states, spin configuration, quantum confinement, and symmetry breaking [10-17]. Aberration correction through multipole-based correctors, as well as the associated improved stability in accelerating voltage, lens supplies, and goniometers in electron microscopes now enables medium-voltage (200-300kV) microscopes to achieve image resolution at or below 0.1nm. Aberration correction not only improves the instrument's spatial resolution but, equally importantly, allows larger objective lens pole-piece gaps to be employed thus realizing the potential of the instrument as a nanoscale property-measurement tool. That is, while retaining high spatial resolution, we can use various sample stages to observe the materials response under various temperature, electric- and magnetic- fields, and atmospheric environments. Such capabilities afford tremendous opportunities to tackle challenging science and technology issues in physics, chemistry, materials science, and biology. The research goal of the electron microscopy group at the Dept. of Condensed Matter Physics and Materials Science and the Center for Functional Nanomaterials, as well as the Institute for Advanced Electron Microscopy, Brookhaven National Laboratory (BNL), is to elucidate the microscopic origin of the physical- and chemical-behavior of materials, and the role of individual, or groups of atoms, especially in their native functional environments. We plan to accomplish this by developing and implementing various quantitative electron microscopy techniques in strongly correlated electron systems and nanostructured materials. As a first step, with the support of Materials Science Division, Office of Basic Energy Science, US Department of Energy, and the New York State Office of Science, Technology, and Academic Research, recently we acquired three aberration-corrected electron microscopes from the three major microscope manufacturers, i.e., JEOL, Hitachi, and FEI. The Hitachi HD2700C is equipped with a probe corrector, the FEI Titan 80-300 has an imaging corrector, while the JEOL2200MCO has both. All the correctors are of the dual-hexapole type, designed and manufactured by CEOS GmbH based on the design due to Rose and Haider [3, 18]. All these three are one-of-a-kind in the US, designed for specialized capabilities in characterizing nanoscale structure. In this chapter, we review the performance of these state-of-the art instruments and the new challenges associated with the improved spatial resolution, including the environment requirements of the laboratory that hosts these instruments. Although each instrument we describe here has its own strengths and drawbacks, it is not our intention to rank them in terms of their performance, especially their spatial resolution in imaging.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scaling of chaos in strongly nonlinear lattices

Although it is now understood that chaos in complex classical systems is the foundation of thermodynamic behavior, the detailed relations between the microscopic properties of the chaotic dynamics and the macroscopic thermodynamic observations still remain mostly in the dark. In this work, we numerically analyze the probability of chaos in strongly nonlinear Hamiltonian systems and find different scaling properties depending on the nonlinear structure of the model. We argue that these different scaling laws of chaos have definite consequences for the macroscopic diffusive behavior, as chaos is the microscopic mechanism of diffusion. This is compared with previous results on chaotic diffusion [M. Mulansky and A. Pikovsky, New J. Phys. 15, 053015 (2013)], and a relation between microscopic chaos and macroscopic diffusion is established.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

General multi-group macroscopic modeling for thermo-chemical non-equilibrium gas mixtures

This paper opens a new door to macroscopic modeling for thermal and chemical non-equilibrium. In a game-changing approach, we discard conventional theories and practices stemming from the separation of internal energy modes and the Landau-Teller relaxation equation. Instead, we solve the fundamental microscopic equations in their moment forms but seek only optimum representations for the microscopic state distribution function that provides converged and time accurate solutions for certain macroscopic quantities at all times. The modeling makes no ad hoc assumptions or simplifications at the microscopic level and includes all possible collisional and radiative processes; it therefore retains all non-equilibrium fluid physics. We formulate the thermal and chemical non-equilibrium macroscopic equations and rate coefficients in a coupled and unified fashion for gases undergoing completely general transitions. All collisional partners can have internal structures and can change their internal energy states after transitions. The model is based on the reconstruction of the state distribution function. The internal energy space is subdivided into multiple groups in order to better describe non-equilibrium state distributions. The logarithm of the distribution function in each group is expressed as a power series in internal energy based on the maximum entropy principle. The method of weighted residuals is applied to the microscopic equations to obtain macroscopic moment equations and rate coefficients succinctly to any order. The model’s accuracy depends only on the assumed expression of the state distribution function and the number of groups used and can be self-checked for accuracy and convergence. We show that the macroscopic internal energy transfer, similar to mass and momentum transfers, occurs through nonlinear collisional processes and is not a simple relaxation process described by, e.g., the Landau-Teller equation. Unlike the classical vibrational energy relaxation model, which can only be applied to molecules, the new model is applicable to atoms, molecules, ions, and their mixtures. Numerical examples and model validations are carried out with two gas mixtures using the maximum entropy linear model: one mixture consists of nitrogen molecules undergoing internal excitation and dissociation and the other consists of nitrogen atoms undergoing internal excitation and ionization. Results show that the original hundreds to thousands of microscopic equations can be reduced to two macroscopic equations with almost perfect agreement for the total number density and total internal energy using only one or two groups. We also obtain good prediction of the microscopic state populations using 5-10 groups in the macroscopic equations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computationally efficient dielectric calculations of molecular crystals

The microscopic dielectric response is a key quantity for electronic materials such as organic semiconductors. Calculations of this response for molecular crystals are currently either expensive or rely on extreme simplifications such as multipole expansions which lack microscopic detail. We present an alternate approach using a microscopic analogue of the Clausius-Mossotti equation, which constructs the dielectric response of a crystal from an eigenvalue decomposition of the dielectric response of individual molecules. This method can potentially be used to examine the effects of defects, disorder, and surfaces on the dielectric properties of molecular solids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Combining molecular dynamics with mesoscopic Green’s function reaction dynamics simulations

In many reaction-diffusion processes, ranging from biochemical networks, catalysis, to complex self-assembly, the spatial distribution of the reactants and the stochastic character of their interactions are crucial for the macroscopic behavior. The recently developed mesoscopic Green’s Function Reaction Dynamics (GFRD) method enables efficient simulation at the particle level provided the microscopic dynamics can be integrated out. Yet, many processes exhibit non-trivial microscopic dynamics that can qualitatively change the macroscopic behavior, calling for an atomistic, microscopic description. We propose a novel approach that combines GFRD for simulating the system at the mesoscopic scale where particles are far apart, with a microscopic technique such as Langevin dynamics or Molecular Dynamics (MD), for simulating the system at the microscopic scale where reactants are in close proximity. This scheme defines the regions where the particles are close together and simulated with high microscopic resolution and those where they are far apart and simulated with lower mesoscopic resolution, adaptively on the fly. The new multi-scale scheme, called MD-GFRD, is generic and can be used to efficiently simulate reaction-diffusion systems at the particle level.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

1.5 nm fabrication of test patterns for characterization of metrological systems

Any metrology tool is only as good as it is calibrated. The characterization of metrology systems requires test patterns at a scale about ten times smaller than the measured features. The fabrication of patterns with linewidths down to 1.5 nm is described. The test sample was designed in such a way that the distribution of linewidths appears to be random at any location. This pseudorandom test pattern is used to characterize dimensional metrology equipment over its entire dynamic range by extracting the modulation transfer function of the system. The test pattern contains alternating lines of silicon and tungsten silicide, each according to its designed width. As a result, the fabricated test samples were imaged using a transmission electron microscope, a scanning electron microscope, and an atomic force microscope. (C) 2015 American Vacuum Society.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advances in full field microscopy with table-top soft x-ray lasers

We describe recent advances in the demonstration of table-top full field microscopes that use soft x-ray lasers for illumination. We have achieved wavelength resolution and single shot exposure operation with a very compact 46.9 nm microscope based on a desk-top size capillary discharge laser. This {lambda}-46.9 nm microscope has been used to capture full field images of a variety of nanostructure systems and surfaces. In a separate development we have demonstrated a zone plate microscope that uses {lambda}=13.2 nm laser illumination to image absorption defects in an extreme ultraviolet lithography (EUVL) mask in the same geometry used in a 4x demagnification EUVL stepper. Characterization of the microscope’s transfer function shows it can resolve 55 nm half period patterns. With these capabilities, the {lambda}-13.2 nm microscope is well suited for evaluation of pattern and defect printability of EUVL masks for the 22 nm node.

36 MATERIALS SCIENCE↗