Search NASA⌕ Search

SEARCH · Search NASA

Results for “module performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

RCT Module 2.10 Access Control and Work Area Setup [Slides]

Terminal Objective: Given the need to perform duties as an RCT, recognize the requirements for access controls and work setup in radiological areas in accordance with RP-PROG-TP-200, Radiation Protection Manual and P-121, Radiation Protection .

61 RADIATION PROTECTION AND DOSIMETRY↗

Thermal Performance Benchmarking: Annual Report

In FY16, the thermal performance of the 2014 Honda Accord Hybrid power electronics thermal management systems were benchmarked. Both experiments and numerical simulation were utilized to thoroughly study the thermal resistances and temperature distribution in the power module. Experimental results obtained from the water-ethylene glycol tests provided the junction-to-liquid thermal resistance. The finite element analysis (FEA) and computational fluid dynamics (CFD) models were found to yield a good match with experimental results. Both experimental and modeling results demonstrate that the passive stack is the dominant thermal resistance for both the motor and power electronics systems. The 2014 Accord power electronics systems yield steady-state thermal resistance values around 42- 50 mm to the 2nd power K/W, depending on the flow rates. At a typical flow rate of 10 liters per minute, the thermal resistance of the Accord system was found to be about 44 percent lower than that of the 2012 Nissan LEAF system that was benchmarked in FY15. The main reason for the difference is that the Accord power module used a metalized-ceramic substrate and eliminated the thermal interface material layers. FEA models were developed to study the transient performance of 2012 Nissan LEAF, 2014 Accord, and two other systems that feature conventional power module designs. The simulation results indicate that the 2012 LEAF power module has lowest thermal impedance at a time scale less than one second. This is probably due to moving low thermally conductive materials further away from the heat source and enhancing the heat spreading effect from the copper-molybdenum plate close to the insulated gate bipolar transistors. When approaching steady state, the Honda system shows lower thermal impedance. Measurement results of the thermal resistance of the 2015 BMW i3 power electronic system indicate that the i3 insulated gate bipolar transistor module has significantly lower junction-to-liquid thermal resistance as compared to the other systems. At a flow rate of 12 liters per minute, the thermal resistance of the i3 systems is only 30 percent of the Accord system and 15 percent of the LEAF system.

30 DIRECT ENERGY CONVERSION↗

Thermal design analysis for SuperTruck II lithium-titanate battery pack

Here, this paper presents a systematic thermal management analysis for a new lithium-titanate-oxide battery pack to be installed in a SuperTruck II, Class 8 hybrid truck. The authors investigate the feasibility of mounting the battery pack inside the vehicle and air-cooling it with fans supplying conditioned air from the cabin. Moreover, the cells within each module are to be immersed in a heat-transfer fluid to improve temperature homogeneity. A multi-stage thermal analysis is performed to ensure adequate thermal regulation of the battery under the proposed design, considering installation and operational constraints. The authors perform thermal and electrical characterization tests on a single cell. Results inform the development of computational fluid dynamics models of the cells, modules, and pack. Module-level analysis shows that the cell temperatures can be maintained below their upper operational limit of 55 °C with module wall-to-air heat transfer coefficients between 10 and 20 Wm -2 K -1 . Pack-level analysis of distinct configurations determines effective airflow paths for adequate heat transfer and delivers a final battery pack design that achieves sufficient cooling and temperature uniformity. A reduced-order electrothermal model is developed to rapidly predict the transient battery performance and to develop a temperature control strategy.

25 ENERGY STORAGE↗

Toward Robust Autotuning of Noisy Quantum dot Devices

The current autotuning approaches for quantum dot (QD) devices, while showing some success, lack an assessment of data reliability. This leads to unexpected failures when noisy or otherwise low-quality data is processed by an autonomous system. In this work, we propose a framework for robust autotuning of QD devices that combines a machine learning (ML) state classifier with a data quality control module. The data quality control module acts as a “gatekeeper” system, ensuring that only reliable data are processed by the state classifier. Lower data quality results in either device recalibration or termination. To train both ML systems, we enhance the QD simulation by incorporating synthetic noise typical of QD experiments. We confirm that the inclusion of synthetic noise in the training of the state classifier significantly improves the performance, resulting in an accuracy of 95.0(9)% when tested on experimental data. We then validate the functionality of the data quality control module by showing that the state classifier performance deteriorates with decreasing data quality, as expected. Our results establish a robust and flexible ML framework for autonomous tuning of noisy QD devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Phase I Trial of Hypofractionated Intensity-Modulated Radiotherapy With Temozolomide Chemotherapy for Patients With Newly Diagnosed Glioblastoma Multiforme

Purpose: To determine the maximal tolerated biologic dose intensification of radiotherapy using fractional dose escalation with temozolomide (TMZ) chemotherapy in patients with newly diagnosed glioblastoma multiforme. Methods and Materials: Patients with newly diagnosed glioblastoma multiforme after biopsy or resection and with adequate performance status, bone marrow, and organ function were eligible. The patients underwent postoperative intensity-modulated radiotherapy (IMRT) with concurrent and adjuvant TMZ. All patients received a total dose of 60 Gy to the surgical cavity and residual tumor, with a 5-mm margin. IMRT biologic dose intensification was achieved by escalating from 3 Gy/fraction (Level 1) to 6 Gy/fraction (Level 4) in 1-Gy increments. Concurrent TMZ was given at 75 mg/m{sup 2}/d for 28 consecutive days. Adjuvant TMZ was given at 150-200 mg/m{sup 2}/d for 5 days every 28 days. Dose-limiting toxicity was defined as any Common Terminology Criteria for Adverse Events, version 3, Grade 3-4 nonhematologic toxicity, excluding Grade 3 fatigue, nausea, and vomiting. A standard 3+3 Phase I design was used. Results: A total of 16 patients were accrued (12 men and 4 women, median age, 69 years; range, 34-84. The median Karnofsky performance status was 80 (range, 60-90). Of the 16 patients, 3 each were treated at Levels 1 and 2, 4 at Level 3, and 6 at Level 4. All patients received IMRT and concurrent TMZ according to the protocol, except for 1 patient, who received 14 days of concurrent TMZ. The median number of adjuvant TMZ cycles was 7.5 (range, 0-12). The median survival was 16.2 months (range, 3-33). One patient experienced vision loss in the left eye 7 months after IMRT. Four patients underwent repeat surgery for suspected tumor recurrence 6-12 months after IMRT; 3 had radionecrosis. Conclusions: The maximal tolerated IMRT fraction size was not reached in our study. Our results have shown that 60 Gy IMRT delivered in 6-Gy fractions within 2 weeks with concurrent and adjuvant TMZ is tolerable in selected patients with a T{sub 1}-weighted enhancing tumor <6 cm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Full Integration of the Fission Product Release Module STACY into the HTR Code Package (HCP) - 18661

The HTR Code Package is under development since 2010 at Forschungszentrum Juelich and at Aachen University. The HCP combines the capabilities of individual legacy codes developed during the German HTR program in a highly integrated manner and contains new features. Within the HCP, all aspects related to fission product release and the redistribution within the primary circuit are handled by the module STACY (Source Term Analysis Code system). STACY is the successor of the codes FRESCO-I/II (dealing with fission product release) and PANAMA (dealing with fuel performance issues). Compared to these predecessor codes, STACY can take amongst others a time-dependent nuclide inventory and a radial temperature profile within the fuel element into account. So far, this version of STACY performs an individual fission product release calculation for a representative number of tracer pebbles. While this version of STACY still relies on codes like VSOP and MGT-3D and contains features such as basic fuel management which are also contained in the before mentioned codes, STACY now will be coupled to forms an integral part of the HCP. Thus, fission product release calculations will be examined with one consistent reactor input model. This allows assessing the release of fission products already during the design phase, besides parameters like the maximum fuel temperature during a transient. Furthermore the total nuclide inventory of a fuel element is distributed among fuel kernels, coating layers, graphite grains and pores of the surrounding matrix graphite. Formerly, this total inventory calculated by the burnup code TNT was distributed according to the distribution of Uranium. As a new feature, STACY now keeps track of the distributions of nuclide inventories within the fuel element. Especially for nuclides mainly formed by activation and decay processes like Ag-110m, this approach is more accurate. Further, the knowledge about the actual nuclide inventories improves the accuracy of fuel performance calculations. In addition, the internal coupling allows a feedback from the fission product calculation to other code modules. Nuclides amounts being released can be considered in e.g. the burnup calculation while calculating the source term of for example tritium or within the calculation which takes care of the redistribution of species by the coolant. Within this paper, the application of the STACY to HTR cores with special emphasis on fission product release to reactor models such as the HTR-Modul and HTR-10 will be discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Surface-wave-assisted nonreciprocity in spatio-temporally modulated metasurfaces

Emerging photonic functionalities are mostly governed by the fundamental principle of Lorentz reciprocity. Lifting the constraints imposed by this principle could circumvent deleterious effects that limit the performance of photonic systems. Most efforts to date have been limited to waveguide platforms. Here, we propose and experimentally demonstrate a spatiotemporally modulated metasurface capable of complete violation of Lorentz reciprocity by reflecting an incident beam into far-field radiation in forward scattering, but into near-field surface waves in reverse scattering. These observations are shown both in nonreciprocal beam steering and nonreciprocal focusing. We also demonstrate nonreciprocal behavior of propagative-only waves in the frequency- and momentum-domains, and simultaneously in both. We develop a generalized Bloch-Floquet theory which offers physical insights into Lorentz nonreciprocity for arbitrary spatial phase gradients, and its predictions are in excellent agreement with experiments. Our work opens exciting opportunities in applications where free-space nonreciprocal wave propagation is desired.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Dynamically robust coordinated set point tracking of distributed DERs at point of common coupling

Low-inertia operation of small-scale power systems, such as a microgrid or a portion of a long feeder, requires careful coordination of the controller performance of the constituting devices. This challenge is exacerbated in microgrids serving the functionalities of a conventional synchronous-based generation unit while comprised of smaller DERs operating mainly interfaced through power electronics converters. This paper builds on the idea of set point modulation and proposes a two-level control strategy that aims to achieve superior performance at the point of common coupling (PCC) of microgrids by combining a local control level with a distributed and coordinated level. Several case studies on both AC and DC systems, the CIGRE low-voltage benchmark system as the AC system and a test DC microgrid, validate the performance of the proposed approach. The real-world applicability of the approach is established via a high-fidelity power hardware-in-the-loop (PHIL) experimental setup and an application case study on grid frequency regulation. The proposed approach enables a microgrid to participate in ancillary service provisions where speed and quality of regulation are critical.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Selection of Components for the Remote, Canister-Monitoring System

This report documents the selection of components as part of the efforts initiated to develop a remote, canister-monitoring system (RCMS) for determining and monitoring environmental conditions within dry fuel storage canisters containing aluminum clad spent nuclear fuel (ASNF) at the Idaho National Laboratory (INL). These efforts are in support of Department of Energy Office of Environmental Management (DOE-EM) investigations into technical issues associated with extended dry storage (50+ years) of ASNF. The capability to establish and monitor the performance of ASNF in situ provides the opportunity to (1) evaluate the appropriate technologies for monitoring, (2) collect canister environment conditions as soon as possible, (3) verify and validate current laboratory-based study results and analytic modeling approaches, and (4) potentially identify additional dry storage options for ASNF at the INL site. The improved understanding of ASNF behavior gained by performing this work would also contribute to the safety basis for extended dry storage in current and future configurations as well as to provide information for future transportation, conditioning, and disposal of ASNF. The parameters to be monitored by the RCMS include temperature, relative humidity, hydrogen gas concentration and radiation environment (dose). Components are selected based on the expected environmental conditions within the canister and fuel storage area, and the desired performance of the RCMS. Several of these components have been purchased and received. Future activities include component testing and calibration, software development for operation of the integrated sensor module and fabrication of a representative test volume. The results of these tests and changes to desired performance characteristics will inform subsequent activities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Patient performance–based plan parameter optimization for prostate cancer in tomotherapy

The purpose of this study is to evaluate the influence of treatment-planning parameters on the quality of treatment plans in tomotherapy and to find the optimized planning parameter combinations when treating patients with prostate cancer under different performances. A total of 3 patients with prostate cancer with Eastern Cooperative Oncology Group (ECOG) performance status of 2 or 3 were included in this study. For each patient, 27 treatment plans were created using a combination of planning parameters (field width of 1, 2.5, and 5 cm; pitch of 0.172, 0.287, and 0.43; and modulation factor of 1.8, 3, and 3.5). Then, plans were analyzed using several dosimetrical indices: the prescription isodose to target volume (PITV) ratio, homogeneity index (HI), conformity index (CI), target coverage index (TCI), modified dose HI (MHI), conformity number (CN), and quality factor (QF). Furthermore, dose-volume histogram of critical structures and critical organ scoring index (COSI) were used to analyze organs at risk (OAR) sparing. Interestingly, treatment plans with a field width of 1 cm showed more favorable results than others in the planning target volume (PTV) and OAR indices. However, the treatment time of the 1-cm field width was 3 times longer than that of plans with a field width of 5 cm. There was no substantial decrease in treatment time when the pitch was increased from 0.172 to 0.43, but the PTV indices were slightly compromised. As expected, field width had the most significant influence on all of the indices including PTV, OAR, and treatment time. For the patients with good performance who can tolerate a longer treatment time, we suggest a field width of 1 cm, pitch of 0.172, and modulation factor of 1.8; for the patients with poor performance status, field width of 5 cm, pitch of 0.287, and a modulation factor of 3.5 should be considered.

61 RADIATION PROTECTION AND DOSIMETRY↗

Towards a new generation of solid total-energy detectors for neutron-capture time-of-flight experiments with intense neutron beams

Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn, such facilities need innovative detection setups that are fast, have low sensitivity to neutrons, can quickly recover from the so-called γ-flash, and offer the highest possible detection sensitivity. In this paper, we present several steps towards such advanced systems. Specifically, we describe the performance of a high-sensitivity experimental setup at CERN n_TOF EAR2. It consists of nine sTED detector modules in a compact cylindrical configuration, two conventional used large-volume C 6 D 6 detectors, and one LaCl 3 (Ce) detector. The performance of these detection systems is compared using 93 Nb(n, γ) data. We also developed a detailed G EANT small4 Monte Carlo model of the experimental EAR2 setup, which allows for a better understanding of the detector features, including their efficiency determination. This Monte Carlo model has been used for further optimization, thus leading to a new conceptual design of a γ detector array, STAR, based on a deuterated-stilbene crystal array. Finally, the suitability of deuterated-stilbene crystals for the future STAR array is investigated experimentally utilizing a small stilbene-d12 prototype. The results suggest a similar or superior performance of STAR with respect to other setups based on liquid-scintillators, and allow for additional features such as neutron-gamma discrimination and a higher level of customization capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Outdoor Deployment Data for a Four-Terminal GaAs//Si Tandem Solar Mini-Module

This dataset contains the complete outdoor measurement and analysis data for a mechanically stacked, four-terminal (4T) gallium arsenide (GaAs)//silicon (Si) tandem solar mini-module deployed from October 2019 to January 2021 at the Solar Radiation Research Laboratory (SRRL) in Golden, Colorado, USA. The data support a performance modeling and degradation analysis framework for tandem photovoltaic devices, as described in the accompanying publication. The dataset includes: (1) current–voltage (J–V) characteristics of each sub-cell measured approximately every five minutes, with extracted performance parameters; (2) spectral irradiance from an EKO MS-710 WISER spectroradiometer, along with derived spectral mismatch ratios (SMR) and average photon energy (APE); (3) one-minute resolution meteorological data from the co-located SRRL weather station and GPS-derived precipitable water vapor (PWV); (4) pre-deployment laboratory characterization (external quantum efficiency, J–V curves, standard test conditions parameters); (5) outdoor-extracted temperature and PWV correction coefficients; and (6) PVcircuit equivalent-circuit simulation outputs used for model validation. Degradation rates of −4.1 ± 0.2 %/year (GaAs) and −2.5 ± 0.9 %/year (Si) were determined using a filtering and normalization methodology adapted for fixed-tilt tandem modules. All data are provided in open, portable formats (Apache Parquet, CSV, JSON) to enable full reproducibility of the published analysis.

14 SOLAR ENERGY↗

Performance of the upgraded PreProcessor of the ATLAS Level-1 Calorimeter Trigger

The PreProcessor of the ATLAS Level-1 Calorimeter Trigger prepares the analogue trigger signals sent from the ATLAS calorimeters by digitising, synchronising, and calibrating them to reconstruct transverse energy deposits, which are then used in further processing to identify event features. During the first long shutdown of the LHC from 2013 to 2014, the central components of the PreProcessor, the Multichip Modules, were replaced by upgraded versions that feature modern ADC and FPGA technology to ensure optimal performance in the high pile-up environment of LHC Run 2. This paper describes the features of the new Multichip Modules along with the improvements to the signal processing achieved.

47 OTHER INSTRUMENTATION↗

Characterization of a mammographic system based on single photon counting pixel arrays coupled to GaAs x-ray detectors

The authors report on the imaging capabilities of a mammographic system demonstrator based on GaAs pixel detectors operating in single photon counting (SPC) mode. The system imaging performances have been assessed by means of the transfer functions: The modulation transfer function (MTF), the normalized noise power spectrum, and the detective quantum efficiency (DQE) have been measured following the guidelines of the IEC 62220-1-2 protocol. The transfer function analysis has shown the high spatial resolution capabilities of the GaAs detectors. The MTF calculated at the Nyquist frequency (2.94 cycles/mm) is indeed 60%. The DQE, measured with a standard mammographic beam setup (Mo/Mo, 28 kVp, with 4 mm Al added filter) and calculated at zero frequency, is 46%. Aiming to further improve the system's image quality, the authors investigate the DQE limiting factors and show that they are mainly related to system engineering. For example, the authors show that optimization of the image equalization procedure increases the DQE(0) up to 74%, which is better than the DQE(0) of most clinical mammographic systems. The authors show how the high detection efficiency of GaAs detectors and the noise discrimination associated with the SPC technology allow optimizing the image quality in mammography. In conclusion, the authors propose technological solutions to exploit to the utmost the potentiality of GaAs detectors coupled to SPC electronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hydrodynamic instability growth and mix experiments at the National Ignition Facility

Hydrodynamic instability growth and its effects on implosion performance were studied at the National Ignition Facility [G. H. Miller, E. I. Moses, and C. R. Wuest, Opt. Eng. 443, 2841 (2004)]. Implosion performance and mix have been measured at peak compression using plastic shells filled with tritium gas and containing embedded localized carbon-deuterium diagnostic layers in various locations in the ablator. Neutron yield and ion temperature of the deuterium-tritium fusion reactions were used as a measure of shell-gas mix, while neutron yield of the tritium-tritium fusion reaction was used as a measure of implosion performance. The results have indicated that the low-mode hydrodynamic instabilities due to surface roughness were the primary culprits for yield degradation, with atomic ablator-gas mix playing a secondary role. In addition, spherical shells with pre-imposed 2D modulations were used to measure instability growth in the acceleration phase of the implosions. The capsules were imploded using ignition-relevant laser pulses, and ablation-front modulation growth was measured using x-ray radiography for a shell convergence ratio of ∼2. The measured growth was in good agreement with that predicted, thus validating simulations for the fastest growing modulations with mode numbers up to 90 in the acceleration phase. Future experiments will be focused on measurements at higher convergence, higher-mode number modulations, and growth occurring during the deceleration phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Volumetric Modulation Arc Radiotherapy With Flattening Filter-Free Beams Compared With Static Gantry IMRT and 3D Conformal Radiotherapy for Advanced Esophageal Cancer: A Feasibility Study

Purpose: A feasibility study was performed to evaluate RapidArc (RA), and the potential benefit of flattening filter-free beams, on advanced esophageal cancer against intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT). Methods and Materials: The plans for 3D-CRT and IMRT with three to seven and five to seven fixed beams were compared against double-modulated arcs with avoidance sectors to spare the lungs for 10 patients. All plans were optimized for 6-MV photon beams. The RA plans were studied for conventional and flattening filter-free (FFF) beams. The objectives for the planning target volume were the volume receiving {>=}95% or at most 107% of the prescribed dose of <1% with a dose prescription of 59.4 Gy. For the organs at risk, the lung volume (minus the planning target volume) receiving {>=}5 Gy was <60%, that receiving 20 Gy was <20%-30%, and the mean lung dose was <15.0 Gy. The heart volume receiving 45 Gy was <20%, volume receiving 30 Gy was <50%. The spinal dose received by 1% was <45 Gy. The technical delivery parameters for RA were assessed to compare the normal and FFF beam characteristics. Results: RA and IMRT provided equivalent coverage and homogeneity, slightly superior to 3D-CRT. The conformity index was 1.2 {+-} 0.1 for RA and IMRT and 1.5 {+-} 0.2 for 3D-CRT. The mean lung dose was 12.2 {+-} 4.5 for IMRT, 11.3 {+-} 4.6 for RA, and 10.8 {+-} 4.4 for RA with FFF beams, 18.2 {+-} 8.5 for 3D-CRT. The percentage of volume receiving {>=}20 Gy ranged from 23.6% {+-} 9.1% to 21.1% {+-} 9.7% for IMRT and RA (FFF beams) and 39.2% {+-} 17.0% for 3D-CRT. The heart and spine objectives were met by all techniques. The monitor units for IMRT and RA were 457 {+-} 139, 322 {+-} 20, and 387 {+-} 40, respectively. RA with FFF beams showed, compared with RA with normal beams, a {approx}20% increase in monitor units per Gray, a 90% increase in the average dose rate, and 20% reduction in beam on time (owing to different gantry speeds). Conclusion: RA demonstrated, compared with conventional IMRT, a similar target coverage and some better dose sparing to the organs at risk; the advantage against conventional 3D-CRT was more evident. RA with FFF beams resulted in minor improvements in plan quality but with the potential for additional useful reduction in the treatment time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

New aspects of improving the performance of WO 3 thin films for photoelectrochemical water splitting by tuning the ultrathin depletion region

In this paper, we explored a facile, scalable and effective method for substantially enhancing photocurrent and incident-photon-to-current efficiency of WO 3 thin-film photoanodes by a mild reduction treatment under low oxygen pressure. Experimental data from photoelectrochemical and electrochemical impedance spectroscopies have shown that such treatment can increase the charge carrier density on WO 3 photoanode surfaces resulting in improvements in hole collection efficiency and reduction in charge recombination. Despite a much thinner layer of WO 3 (about 500 nm) compared to those in other published studies, the electrodes exhibited an ultra-high photocurrent density of 1.81 mA cm –2 at 1.23 V vs . RHE. This current density is one of the highest ones among WO 3 -based photoanodes described in literature. As a result, the proposed surface modulation approach offers an effective and scalable method to prepare high-performance thin film photoanodes for photoelectrochemical water splitting.

36 MATERIALS SCIENCE↗

Image filtering as an alternative to the application of a different reconstruction kernel in CT imaging: Feasibility study in lung cancer screening

Purpose: While the acquisition of projection data in a computed tomography (CT) scanner is generally carried out once, the projection data is often removed from the system, making further reconstruction with a different reconstruction filter impossible. The reconstruction kernel is one of the most important parameters. To have access to all the reconstructions, either prior reconstructions with multiple kernels must be performed or the projection data must be stored. Each of these requirements would increase the burden on data archiving. This study aimed to design an effective method to achieve similar image quality using an image filtering technique in the image space, instead of a reconstruction filter in the projection space for CT imaging. The authors evaluated the clinical feasibility of the proposed method in lung cancer screening. Methods: The proposed technique is essentially the same as common image filtering, which performs processing in the spatial-frequency domain with a filter function. However, the filter function was determined based on the quantitative analysis of the point spread functions (PSFs) measured in the system. The modulation transfer functions (MTFs) were derived from the PSFs, and the ratio of the MTFs was used as the filter function. Therefore, using an image reconstructed with a kernel, an image reconstructed with a different kernel was obtained by filtering, which used the ratio of the MTFs obtained for the two kernels. The performance of the method was evaluated by using routine clinical images obtained from CT screening for lung cancer in five subjects. Results: Filtered images for all combinations of three types of reconstruction kernels (''smooth,''''standard,'' and ''sharp'' kernels) showed good agreement with original reconstructed images regarded as the gold standard. On the filtered images, abnormal shadows suspected as being lung cancers were identical to those on the reconstructed images. The standard deviations (SDs) for the difference between filtered images and reconstructed images ranged from 1.9 to 23.5 Hounsfield units for all kernel combinations; these SDs were much smaller than the noise SDs in the reconstructed images. Conclusions: The proposed method has good performance and is clinically feasible in lung cancer screening. This method can be applied to images reconstructed on any scanner by measuring the PSFs in each system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗