Search NASA⌕ Search

SEARCH · Search NASA

Results for “prototypes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Ultrafast Neuromorphic Dynamics Using Hidden Phases in the Prototype of Relaxor Ferroelectrics

Materials possessing multiple states are promising to emulate synaptic and neuronic behaviors. Their operation frequency, typically in or below the GHz range, however, limits the speed of neuromorphic computing. Ultrafast THz electric field excitation has been employed to induce nonequilibrium states of matter, called hidden phases in oxides. One may wonder if there are systems for which THz pulses can generate neuronic and synaptic behavior, via the creation of hidden phases. Using atomistic simulations, we discover that relaxor ferroelectrics can emulate all the key neuronic and memristive synaptic features. Their occurrence originates from the activation of many hidden phases of polarization order, resulting from the response of nanoregions to THz pulses. We find such phases further possess different dielectric constants, which is also promising for memcapacitor devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Schistosoma mansoni venom allergen-like protein 4 (SmVAL4) is a novel lipid-binding SCP/TAPS protein that lacks the prototypical CAP motifs

The first structure of an S. mansoni venom allergen-like protein is presented. Schistosomiasis is a parasitic disease that affects over 200 million people. Vaccine candidates have been identified, including Schistosoma mansoni venom allergen-like proteins (SmVALs) from the SCP/TAPS (sperm-coating protein/Tpx/antigen 5/pathogenesis related-1/Sc7) superfamily. The first SmVAL structure, SmVAL4, was refined to a resolution limit of 2.16 Å. SmVAL4 has a unique structure that could not be predicted from homologous structures, with longer loops and an unusual C-terminal extension. SmVAL4 has the characteristic α/β-sandwich and central SCP/TAPS cavity. Furthermore, SmVAL4 has only one of the signature CAP cavity tetrad amino-acid residues and is missing the histidines that coordinate divalent cations such as Zn{sup 2+} in other SCP/TAPS proteins. SmVAL4 has a cavity between α-helices 1 and 4 that was observed to bind lipids in tablysin-15, suggesting the ability to bind lipids. Subsequently, SmVAL4 was shown to bind cholesterol in vitro. Additionally, SmVAL4 was shown to complement the in vivo sterol-export phenotype of yeast mutants lacking their endogenous CAP proteins. Expression of SmVAL4 in yeast cells lacking endogenous CAP function restores the block in sterol export. These studies suggest an evolutionarily conserved lipid-binding function shared by CAP proteins such as SmVAL4 and yeast CAP proteins such as Pry1.

60 APPLIED LIFE SCIENCES↗

High power RF conditioning of 2856 MHz, 40 keV prototype buncher cavity system

An on axis biperiodic buncher cavity system at 2856 MHz with three bunching cells plus one power feed cell has been designed and fabricated for 40 keV pulsed electron beam injection from a thermionic gun. The vacuum and high power RF conditioning prior to the beam injection is presented in this paper. Initially the cavity system along with the in-flange fast current transformer and the beam diagnostics chamber has been baked at 60-65 °C for 22 hours under a vacuum ≤ 6 x 10{sup -6} mbar. The final ultimate vacuum was 2.3 x 10{sup -6} mbar and it took 195 seconds to reach to 1 x 10{sup -5} mbar with the gate valve closed. After this the high power RF conditioning was done from 0.3 MW to 1.2 MW input RF power with 4μsec. pulse at 1 Hz PRF. At this point the ultimate vacuum reached to 2.3 x 10{sup -6} mbar and reached to 1 x 10{sup -5} mbar in 195 seconds after closing the gate valve. Finally the system was conditioned with 1MW, 4μsec. RF pulses at 20 Hz PRF. (author)

43 PARTICLE ACCELERATORS↗

A Prototype Gamma Tomosynthesis System for Molecular Breast Imaging

We are developing an improved gamma camera for molecular breast imaging (MBI) that allows tomographic imaging and improved signal-to-noise over conventional planar methods. We have built a novel gamma camera for MBI that utilizes limited angle tomography, similar to x-ray tomosynthesis, to generate images with depth information and improved signal-to-noise. A unique feature of the gamma tomosynthesis system is a variable-angle slant hole (VASH) collimator. This collimator allows the camera to remain flush against the compression paddle during the tomographic acquisition, which achieves high spatial resolution and simplified detector motion. We constructed a VASH collimator from a stack of tungsten sheets, each sheet containing a matrix of holes created by photo-etching. With the holes of the sheets aligned, a parallel-hole collimator is created; shearing the sheets creates a variable angle slant hole collimator. The shearing is controlled by a motorized mechanism. The collimator was mounted on a commercial MBI camera and projection data were acquired of a set of capillary tube line sources over a 50° range of angles. The projection data were reconstructed using the iterative MLEM method. Results demonstrated the ability of the system to resolve in the depth dimension, and spatial resolution matched expected values. We conclude that the proposed gamma tomosynthesis system has the potential to provide improved signal-to-noise over conventional MBI methods and allow a reduction in the administered radioactivity and patient dose.

Gilland, David↗

Tests of a Prototype for Assessing the Field Homogeneity of the Iseult/Inumac 11.7T Whole Body MRI Magnet

A neuroscience research center with very high field MRI equipments has been opened in November 2006 by the CEA life science division. One of the imaging systems will require a 11.75 T magnet with a 900 mm warm bore, the so-call Iseult/Inumac magnet. Regarding the large aperture and field strength, this magnet is a challenge as compared to the largest MRI systems ever built, and is then developed within an ambitious R&D program. With the objective of demonstrating the possibility of achieving field homogeneity better than 1 ppm using double pancake windings, a 24 double pancakes model coil, working at 1.5 T has been designed. This model magnet has been manufactured by Alstom MSA and tested at CEA. It has been measured with a very high precision, in order to fully characterize the field homogeneity, and then to investigate and discriminate the parameters that influence the field map. This magnet has reached the bare magnet field homogeneity specification expected for Iseult and thus successfully demonstrated the feasibility of building a homogenous magnet with the double pancake winding technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fabrication of Bi-2212 Canted-Cosine-Theta Dipole Prototypes

The U.S. Magnet Development Program (MDP) is exploring the possibility of combining low-and higherature superconductor technologies, using cosine-theta and canted-cosine-theta (CCT) Nb3Sn dipole magnets together with Bi-2212 CCT inserts, with the ultimate goal of constructing a 20-T dipole. The MDP short-term goal is a Bi-2212 CCT insert capable of reaching 5 T in the bore when operating as a stand-alone and 3 T when operating under a background field of 15 T. This paper reports on the fabrication of our BIN4 dipole magnet and our BIN5a and BIN5b coils, designed and built at the Lawrence Berkeley National Laboratory to address potential fabrication issues of Bi-2212 coils and verify the design of our 18-20-T dipole magnet. BIN4 is a two-layer 50-cm-long CCT magnet that uses a nine-strand Rutherford cable made with 0.8-mm-diameter Bi-2212 strands. Its goal is to investigate critical current, insulation integrity, manufacturing challenges, and quench protection issues after heat treating both layers together under oxygen at standard atmosphere (1 bar). BIN5a and BIN5b are two identical coils, similar to the outer layer of BIN4, with the difference that the length is 39 cm, and they will undergo 50-bar overpressure processing heat treatment. Finally, BIN5 coils are made from the state-of-the-art strand with an engineering critical current density of 1150 A/mm 2 at 4.2 K and 5 T.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Performance of a Quintuple-GEM Based RICHDetector Prototype

Cerenkov technology is often the optimal choice for particle identification in high energy particle collision applications. Typically, the most challenging regime is at high pseudorapidity (forward) where particle identification must perform well at high laboratory momenta. For the upcoming electron ion collider (EIC), the physics goals require hadron (π, K, p) identification up to ~50 GeV/c. In this region Cerenkov ring-imaging (RICH) is the most viable solution. The speed of light in a radiator medium is inversely proportional to the refractive index. Hence, for particle identification (PID) reaching out to high momenta a small index of refraction is required. Unfortunately, the lowest indices of refraction also result in the lowest light yield ([(dNγ)/dx] ∝ sin2(θC)) driving up the radiator length and thereby the overall detector cost. In this paper we report on a successful test of a compact RICH detector (1 meter radiator) capable of delivering in excess of 10 photoelectrons per ring with a low index radiator gas (CF4). The detector concept is a natural extension of the PHENIX hadron-blind detector (HBD) achieved by adding focusing capability at low wavelength and adequate gain for high efficiency detection of single-electron induced avalanches. Our results indicate that this technology is indeed a viable choice in the forward direction of the EIC. The setup and results are described within.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗